Loading...
HomeMy WebLinkAboutR-435495- —AOHP 2 OHP----- OHP----0 6 42 OHP-----OHP----W 0-- 1-----1— W ----W-----— --- —"V -- 404 1 -- --_ — —T o D LO N 10 40 1 0 20 60 0 GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH CITY OF RENTON STANDARD PLANS AND SPECIFICATIONS, THE WASHINGTON DEPARTMENT OF TRANSPORTATION (WSDOT) STANDARD PLANS AND SPECIFICATIONS, THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD), AND THE CONTRACT, UNLESS OTHERWISE NOTED. 2. A COPY OF THE APPROVED PLANS SHALL BE ON SITE DURING CONSTRUCTION. 3. ALL PERMITS REQUIRED FOR WORK WITHIN THE PUBLIC RIGHT-OF-WAY MUST BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. THE CONTRACTOR SHALL FIELD VERIFY AND STAKE FINAL LOCATIONS OF ALL PROPOSED FB POLES AND FOUNDATIONS WITH THE ENGINEER PRIOR TO INSTALLATION. ALL PROPOSED SIGNS AND FOUNDATIONS SHALL BE LOCATED WITHIN RIGHT-OF-WAY AND PANELS SHALL NOT OVERHANG OUTSIDE OF RIGHT-OF-WAY. SIGN PANELS THAT OVERHANG SIDEWALKS/PATHWAYS SHALL HAVE A MINIMUM VERTICAL CLEARANCE OF 7FT FROM THE BOTTOM OF THE LOWEST PANEL TO THE ADJACENT SIDEWALK/PATHWAY SURFACE. 5. SIGN CODES REFER TO THE MUTCD. 6. THE LOCATION OF EXISTING FEATURES AND UTILITIES SHOWN WITHIN THESE PLANS ARE APPROXIMATE AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO COMMENCING ELECTRICAL WORK. NOT ALL EXISTING FEATURES AND UTILITIES MAY BE SHOWN. 7. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT UTILITY AGENCIES 48 HOURS PRIOR TO COMMENCING WORK AND SHALL COORDINATE WITH ALL AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO EXISTING UTILITIES RESULTING FROM CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY AGENCY IMMEDIATELY UPON DAMAGE AND SHALL BE RESPONSIBLE FOR REPLACING DAMAGED EQUIPMENT TO THE SATISFACTION OF THE AFFECTED UTILITY AGENCY. 8. THE CONTRACTOR SHALL CHECK FOR MINIMUM OVERHEAD CLEARANCE BETWEEN ANY OVERHEAD POWER AND COMMUNICATION LINES PRIOR TO PLACING FOUNDATIONS. I I I o I I 3 _ 133+00 I G --- --- — — 1 4 I SE 128TH ST I to--T-----T-----T — „ �a- — A- T — - LEGEND --- OHP----- OHP L—� C 1 &+00 320' 38+00 —----T4---/-T----I--T .. ._Q ,. a ,.• a ----- -- _ ---- a 1 a n p n 411, -- — o— --- — . - �-, -61 D a �— _� A V'IIOOAF.*Ji MOVES VIVO, • 4. OI--m--- A-- ie'l rr A'.: III gI 1111111111111 111A.4 •Q p 1 _ _______ ; .' .i I ' e � - 4—e i i 0 SINGLE -SIDED CIRCULAR FLASHING BEACON POLE AND ASSEMBLY IS CONTROLLER CABINET A. GROUND MOUNTED SIGN ® CONSTRUCTION NOTE ® POLE NOTE ® SIGN NOTE — — CONDUIT 0 TYPE 2 JUNCTION BOX B TYPE 1 JUNCTION BOX CONSTRUCTION NOTES O CONSTRUCT FOUNDATION AND INSTALL SINGLE -SIDED R247-MX BEACON SYSTEM WITH MX400 AC CONTROL CABINET, TRAP LORA WIRELESS REMOTE CONTROL SYSTEM RECEIVER, PELCO POLE AND BASE, SIGN(S), AND ALL APPURTENANCES PER DETAILS ON SHEET FB02. O CONSTRUCT FOUNDATION AND INSTALL SINGLE -SIDED R247-MX BEACON SYSTEM, PELCO POLE AND BASE, SIGN(S), AND ALL APPURTENANCES PER DETAILS ON SHEET F1302. O INSTALL STREET SIGN POST AND FOUNDATION PER CITY OF RENTON STANDARD PLAN 129. ® SEE SITE ELECTRICAL PLAN E3.1 FOR CONDUIT AND PUSHBUTTON CONDUCTOR ROUTING TO FIRE STATION BUILDING. O TERMINATE FB POWER IN 20AMP BREAKER WITHIN SERVICE CABINET. SEE ELECTRICAL PLAN E3.1 FOR DETAILS. © INSTALL TYPE 2 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.10-04. O INSTALL TYPE 1 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.10-04. DATE REVISION BY DATE DESIGNED BY TDL 08/25/2025 DRAWN BY MPL 08/25/2025 REVIEWED BY TDL 08/25/2025 0 l P1 n FB POLE SCHEDULE POLE NO. STATIONING CENTERLINE STATION OFFSET CONFIGURATION COMMENTS 1 SR 128TH ST 33+13.1 36'-6" RT UNI-DIRECTIONAL CFB WITH CONTROLLER 2 SR 128TH ST 34+34.6 36'-1" LT UNI-DIRECTIONAL CFB SIGN SCHEDULE SIGN NO. SIGN CODE NUMBER DESCRIPTION DIMENSIONS ALIGNMENT STATION OFFSET COMMENTS 1A W1 1-8 EMERGENCY VEHICLE 36" X 36" NEW SEE PLAN VIEW FOR PLACEMENT DIMENSIONS 1 B W16-9P AHEAD NEW 24" X 12" 2A W1 1-8 EMERGENCY VEHICLE 36" X 36" NEW SEE PLAN VIEW FOR PLACEMENT DIMENSIONS 2B W16-9P AHEAD NEW 24" X 12" WIRING SCHEDULE RACEWAY CONDUIT SIZE* #8 RRFB POWER 4C FLASHERS* 8C PPB* #8 GROUND CONDUIT FILL % 1 2" SCH40 2 1 5.65% 2 2" SCH40 2 1 1 1 22.06% 2" SCH80 1 1 8.42% 3 2" SCH80 SPARE - WITH PULL ROPE 4 2" SCH40 1 1 7.35% 5 2" SCH40 1 1 12.82% 6 2" SCH40 1 1 1 18.29% *GENERAL CONDUCTORS SHOWN FOR CONDUIT SIZING PURPOSES. ACTUAL CONDUCT TYPE SHALL BE PER MANUFACTURER'S SPECIFICATIONS. transpogroup WHAT TRANSPORTATION CAN BE. IF 12131 113TH AVENUE NE, SUITE 203 (TEL) 425 821-3665 KIRKLAND, WASHINGTON 98034 (FAX) 425 825-8434 SIGN LEGEND W1 1-8 B/Y 1A 2A AHEAD jj W16-9P B/Y 1B 2B DEVELOPMENT ENGINEERING H H uyn h 09/23/2025 F ANSPORTATION OPERATION cbarnes 09/23/2025 % Know what's below. Call before you dig. RENTON REGIONAL FIRE STATION #16 AUGUST 2025 EMERGENCY VEHICLE WARNING PLANS FB01 SHEET 1 OF 3 SHEETS R-435495