Loading...
HomeMy WebLinkAboutRECHECK REPORT (UA TRADE-OFF)_SEPT 25, 2025Report Title: 2025 Addition Report Date: 9/28/25, 10:07 PM 1 of 3 Compliance Certificate Project Information Project Title: Energy Code: Location: Construction Type: Project Type: Project Sub Type: Orientation: Glazing Area: Climate Zone: Permit Date: Permit No: Project No: All Electric: Is Renewable: Has Battery: Has Charger: Has Heat Pump 2025 Addition 2021 IECC Renton, Washington Single Family Addition None Bldg. faces 270 deg. from North 10% 4c (4611 HDD) 2025-03-26 B25001946 1762635 false false false false true Construction Site:Owner/Agent:Designer/Contractor: 2614 Whitman Ave NE Renton , Washington 98059 Dan Garland 2614 Whitman Ave NE Renton , Washington 98059 4252412778 dan.garland@outlook.com Project Notes: Owner is contractor Energy Credits Description Credits More Efficient HVAC Equipment Option - R408.2.2 1.0 Not applicable Report Title: 2025 Addition Report Date: 9/28/25, 10:07 PM 2 of 3 Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. U- Factor/ F-Factor Req. U- Factor/ F-Factor Prop. UA Req. UA Ceiling: Flat Ceiling or Scissor Truss 773 60.0 0.0 0.024 0.024 19 19 Floor: All-Wood Joist/Truss 750 30.0 10.0 0.024 0.033 18 25 West Wall: Wood Frame, 16" o.c.  Orientation: Front 296 21.0 0.0 0.057 0.045 15 12 West Windows: Vinyl Frame  Orientation: Front 36 0.270 0.300 10 11 South Wall: Wood Frame, 16" o.c.  Orientation: Right side 200 21.0 0.0 0.057 0.045 11 8 South Windows: Vinyl Frame  Orientation: Right side 12 0.270 0.300 3 4 North Wall: Wood Frame, 16" o.c.  Orientation: Left side 200 21.0 0.0 0.057 0.045 10 8 North Windows: Vinyl Frame  Orientation: Left side 18 0.270 0.300 5 5 East of addition connects to house: Wood Frame, 16" o.c.  Orientation: Back 1 21.0 0.0 0.057 0.045 0 0 Compliance: Passes using UA trade-off Compliance: 1.1% Better Than Code Max UA: 92 Your UA: 91 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Compliance Statement The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2021 IECC requirements in REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date Report Title: 2025 Addition Report Date: 9/28/25, 10:07 PM 3 of 3 2021 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 0.00 Floor 40.00 Ceiling / Roof 60.00 Ductwork (unconditioned spaces):_____ Glass & Door Rating U-Factor SHGC Window 0.27 0.28 Door 0.00 Skylight 0.00 Heating & Cooling Equipment Efficiency Heating System: ____________________________________________ Cooling System: ____________________________________________ Water Heater: ____________________________________________ Signature Name: ______________________Date: ______________________ Comments: