HomeMy WebLinkAbout51-Photometrics_and_site electrical plan.pdfW 1 2 2 2 2 3 3 3 3 3 1 1222223 3 3 3 3 DEMOLITION NOTES EXISTING UTILITY POLE TO REMAIN. EXISTING UTILITY POLE TO BE REMOVED. EXISTING OVERHEAD POWER TO BE REMOVED. 1 2 3 EXISTING PIV AND FIRE ALARM CONDUIT DEMOED WITH BLDG C PIV EXISTING CABLE TV SERVICE OVERHEAD CABLE FROM POLE DEMOED WITH BUILDING C. EXISTING LEVEL 1 IDF DEMOED WITH BLDG C EXISTING UNDERGROUND CONDUIT DEMOED WITH BLDG B & C EXISTING UNDERGROUND CONDUIT DEMOED WITH BLDG B EXISTING LEVEL 2 IDF DEMOED WITH BLDG B EXISTING LEVEL 3 WEST IDF DEMOVED WITH WEST WING. EXISTING LEVEL 2 WEST MDF DEMOVED WITH WEST WING. EXISTING LEVEL 1 WEST IDF DEMOVED WITH WEST WING. V PIV EXISTING SERVICE PROVIDER VAULT TO REMAIN UNTIL SERVICE IS OPERATIONAL AND NEW BACKBONE FEEDS TO EXISTING TO REMAIN IDF'S WITHIN THE 1930'S BUILDING ARE COMPLETE. EXISTING PIV AND FIRE ALARM CONDUIT TO REMAIN. (VERIFY EXACT CONDUIT AND WATER ROUTING.) EXISTING LEVEL 1 EAST IDF TO REMAIN EXISTING LEVEL 2 EAST MDF TO REMAIN EXISTING LEVEL 3 EAST IDF DEMOVED WITH EAST WING. EXISTING LEVEL 1 IPAC IDF TO REMAIN EXISTING SERVICE PROVIDER CONDUIT TO REMAIN UNTIL CUT IN WEST WING DEMO. COORDINATE WITH OWNER FOR UTILITY SWAP OVERS TO NEW MDF PRIOR TO DISCONNECTING.date phase revisions date project RE N T O N H I G H S C H O O L RE P L A C E M E N T T 4 2 5 . 2 0 4 . 2 3 0 0 RE N T O N S C H O O L D I S T R I C T DD SET 40 0 S O U T H 2 N D S T R E E T , R E N T O N , W A 9 8 0 5 7 06/06/2025 23007 NOT F O R C O N S T R U C T I O N E1.04 EXISTING TELECOM SITE PLANSCALE: 1" = 60'-0"1EXISTING TELECOM SITE PLAN W DN NEW IDF NEW IDF NEW IDF NEW IDF NEW MDF V V EXISTING IDF EXISTING IDF V NEW ELECTRICAL ROOM NEW FIRE RISER ROOM CONSTRUCTION NOTES (2) 4" CONDUITS FROM EACH VAULT TO MDF WITH PULL STRING IN EACH CONDUIT. PROVIDE (2) 4" CONDUITS -(1) WITH 3-CELL MAXCELL INNERDUCT. -(1) WITH PULL STRING AS SPARE. PROVIDE (4) 4" CONDUITS -(2) WITH 3-CELL MAXCELL INNERDUCT. -(2) WITH PULL STRING AS SPARE. PROVIDE (6) 4" CONDUITS -(4) WITH 3-CELL MAXCELL INNERDUCT. -(2) WITH PULL STRING AS SPARE. PROVIDE (4) 2" CONDUITS -(3) WITH 3-CELL MAXCELL INNERDUCT. -(1) WITH PULL STRING AS SPARE. PROVIDE (1) 1" CONDUIT WITH PULL STRING FOR GROUND AND BONDING CONDUCTORS. PROVIDE (1) 1" CONDUIT WITH PULL STRING FROM ELECTRICAL OR FIRE RISER ROOM TO MDF/IDF ROOMS. 253LA VAULTS FOR SERVICE PROVIDERS. PROVIDE HOMERUN 1" CONDUIT FROM MAIN ELECTRICAL ROOM TO EACH GROUND LEVEL MDF/IDF ROOM LISTED FOR TELECOM GROUND AND BONDING INFRASTRUCTURE. SEE RISER DIAGRAMS FOR ADDITIONAL INFORMATION. 6 6 6 6 1 2 3 4 5 6 7 8 2 2 2 3 7 5 1 1 7 7 5 7 4 ROUTE ALL NEW CONDUIT PATHWAYS ADJACENT TO EACH OTHER THROUGH THE EXISTING IPAC BULDING CEILING SPACE. 9 NEW MAIN ELECTRICAL ROOM 9 7 date phase revisions date project RE N T O N H I G H S C H O O L RE P L A C E M E N T T 4 2 5 . 2 0 4 . 2 3 0 0 RE N T O N S C H O O L D I S T R I C T DD SET 40 0 S O U T H 2 N D S T R E E T , R E N T O N , W A 9 8 0 5 7 06/06/2025 23007 NOT F O R C O N S T R U C T I O N E1.05 EXISTING/NEW TELECOM SITE PLANSCALE: 1" = 60'-0"1EXISTING/NEW TELECOM SITE PLAN DS DS DS DS DS DS DS DS DS DS DSDS DS DS DS DS DS DS DS DS DS DSDSDSDS DS DS DS DS DS DS DS DS DS DS DS DS DS DS S 2 N D S T S 2 N D S T L O G A N A V E S L O G A N A V E S L O G A N A V E S S T O B I N S T S T O B I N S T L O G A N A V E S S H A T T U C K A V E S L A K E A V E S L A K E A V E S A I R P O R T W A Y A I R P O R T W A Y S 2 N D S T L A K E A V E S S T O B I N S T S T O B I N S T NEW IDF NEW IDF NEW IDF NEW IDF NEW MDF V V EXISTING IDF EXISTING IDF V NEW ELECTRICAL ROOM NEW FIRE RISER ROOM CONSTRUCTION NOTES EXISTING (2) 4" CONDUITS FROM EACH VAULT TO MDF WITH PULL STRING IN EACH CONDUIT. EXISTING (2) 4" CONDUITS -(1) WITH 3-CELL MAXCELL INNERDUCT. -(1) WITH PULL STRING AS SPARE. EXISTING PROVIDE (4) 4" CONDUITS -(2) WITH 3-CELL MAXCELL INNERDUCT. -(2) WITH PULL STRING AS SPARE. EXISTING (6) 4" CONDUITS -(4) WITH 3-CELL MAXCELL INNERDUCT. -(2) WITH PULL STRING AS SPARE. EXISTING (4) 2" CONDUITS -(3) WITH 3-CELL MAXCELL INNERDUCT. -(1) WITH PULL STRING AS SPARE. EXISTING (1) 1" CONDUIT WITH PULL STRING FOR GROUND AND BONDING CONDUCTORS. EXISTING (1) 1" CONDUIT WITH PULL STRING FROM ELECTRICAL OR FIRE RISER ROOM TO MDF/IDF ROOMS. EXISTING 253LA VAULTS FOR SERVICE PROVIDERS. EXISTING HOMERUN 1" CONDUIT FROM MAIN ELECTRICAL ROOM TO EACH GROUND LEVEL MDF/IDF ROOM LISTED FOR TELECOM GROUND AND BONDING INFRASTRUCTURE. SEE RISER DIAGRAMS FOR ADDITIONAL INFORMATION. PROVIDE (2) 4" CONDUITS -(1) WITH 3-CELL MAXCELL INNERDUCT. -(1) WITH PULL STRING AS SPARE. PROVIDE (3) 4" CONDUITS -(2) WITH 3-CELL MAXCELL INNERDUCT. -(1) WITH PULL STRING AS SPARE. PROVIDE (4) 4" CONDUITS -(3) WITH 3-CELL MAXCELL INNERDUCT. -(1) WITH PULL STRING AS SPARE. PROVIDE (6) 4" CONDUITS -(4) WITH 3-CELL MAXCELL INNERDUCT. -(2) WITH PULL STRING AS SPARE. PROVIDE (1) 4" CONDUIT WITH 3-CELL MAXCELL INNERDUCT. 6 6 6 6 1 2 3 4 5 6 7 8 2 2 2 3 7 5 1 1 7 7 5 7 4 ROUTE ALL NEW CONDUIT PATHWAYS ADJACENT TO EACH OTHER THROUGH THE EXISTING IPAC BULDING CEILING SPACE. 9 NEW MAIN ELECTRICAL ROOM 9 7 10 V VV V V V V V 11 11 11 10 10 12 12 12 13 13 1010 NEW IDF 10 12 14 14 NEW IDF date phase revisions date project RE N T O N H I G H S C H O O L RE P L A C E M E N T T 4 2 5 . 2 0 4 . 2 3 0 0 RE N T O N S C H O O L D I S T R I C T DD SET 40 0 S O U T H 2 N D S T R E E T , R E N T O N , W A 9 8 0 5 7 06/06/2025 23007 NOT F O R C O N S T R U C T I O N E1.06 SCALE: 1" = 60'-0"1 NEW TELECOM SITE PLAN NEW TELECOM SITE PLAN WHWH 30'-0" 32 ' - 0 " A10.03 A10.03 4B 4D REF A10.03 4A E10e TYP. EXTERIOR WALL A-20e TYP. INTER. WALL REF MS A10c A10c A10c 12" CONCRETE SLAB ON GRADE 5 A10.03 CONCESSIONS/TICKETS S101A ELEC S101B RR S101C MEN S101D WOMEN S101E RR S101F IDF S101G STORAGE S101H S101B-1 S101C-1 S101D-1 S101E-1 S101F-1 S1 0 1 G - 1 S1 0 1 H - 1 S101A-1 S1 0 1 A - 2 S1 0 1 A - 2 A10.45 1 A-20d A-20dA10.03 6B 6A 6D 6C R-11 ROOF SLOPE 1/4" / 12 4'-0"4'-0" 6" DS DF HB DS GUTTER / DS HM DOOR / FRAME BV1a 5 A10.03 11 ' - 0 " HM DOOR / FRAME, PAINT BV1a NORTH ELEVATION SIM SS ROLL UP COUNTER DOOR BV1a 5 A10.03 SS COUNTER CONCESSIONS/TICKETS S101A RR S101C MEN S101D WOMEN S101E RR S101F ELEC S101B IDF S101G STORAGE S101H 9'-0" 9'-6" 9'-6" 9'-6" 9'-6" OTS OTS OTS WALL CONSTRUCTION TYPE -SEE WALL TYPES SHEET WHERE SHOWN, INDICATES FIRE RESISTANCE IN HOURS A 55 -2 b WALL NUMBER INDICATED ON WALL TYPES SHEET WALL FUNCTION (A = INTERIOR; E = EXTERIOR) WALL STRUCTURE AS NOTED IN WALL ASSEMBLY A55-2b WALL TAG WHERE OCCURS, TRIANGLE INDICATES ORIENTATION OF WALL ASSEMBLY: TRIANGLE IS THE RIGHT SIDE OF WALL TYPE SHOWN ON THE WALL ASSEMBLY SHEET. LEGEND INDICATES WALL CALLED OUT BY WALL TAG. SEE SHEET NOTES FOR ADDITIONAL INFORMATION. SHEET NOTES 1. CONDITIONS AND DETAILS MARKED "TYPICAL" SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. TYPICAL DETAILS NOT REFERENCED ON DRAWINGS APPLY UNLESS NOTED OTHERWISE BY SPECIFIC NOTES AND DETAILS. WHERE NO SPECIFIC DETAIL IS SHOWN, THE CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO THAT INDICATED FOR THE TYPICAL CONSTRUCTION OF THE PROJECT. 2. LOADING OF CONSTRUCTION MATERIALS SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. 3. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING WITH APPROPRIATE TRADES, DRAWINGS, AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. 4. PROVIDE ALL NECESSARY ANCHORAGE BLOCKING, BACKING, FRAMING FOR HANDRAILS, DOOR STOPS, CASEWORK, SHELVING, MIRRORS, WALL MOUNTED EQUIPMENT, AND ALL OTHER ITEMS AS REQUIRED FOR COMPLETE INSTALLATION. 5. CONFIRM ALL ROUGH OPENING DIMENSIONS FOR DOORS AND WINDOWS PRIOR TO COMMENCEMENT OF CONSTRUCTION. 6. UNLESS NOTED OTHERWISE, ENTIRE WALL ASSEMBLY OF ALL INTERIOR WALLS AND PARTITIONS SHALL EXTEND TO THE UNDRESIDE OF THE FLOOR DECK OR ROOF DECK ABOVE 7. WHERE A LENGTH OF WALL IS INTERSECTED BY PERPENDICULAR WALLS, WALL TYPE TO BE CONTINUOUS BETWEEN TAGS UNLESS NOTED OTHERWISE. 8. PROVIDE SOLID BLOCKING BETWEEN ROOF JOISTS WHERE WALL RUNS PERPENDICULAR TO ROOF JOISTS. GYPSUM BOARD TO TERMINATE AT ROOF JOISTS. 9. ALIGN FINISHES WHERE INDICATED. 10. SEE PLANS FOR LOCATIONS OF WRAPPED STRUCTURAL STEEL COLUMNS, SEE A0.10 FOR DETAILS * FOR SHAFT WALL STRUCTURE, DIMENSION INCLUDES 1" WALL PANEL. ** MASONRY DIMENSIONS ARE NOMINAL *** DIMENSIONS MAY BE FOR REFERENCE. ACTUAL STRUCTURAL THICKNESS IS PROVIDED BY THE STRUCTURAL ENGINEER METAL STUD*: a = 1-7/8" b = 2-1/2" c = 4" d = 6" e = 8" f = 10" g = 12" MASONRY** : a = na b = na c = 4" d = 6" e = 8" f = 10" g = 12" CONCRETE***: a = na b = na c = 4" d = 6" e = 8" f = 10" g = 12" h = 14" LEGEND: GYPSUM BOARD CEILING PAINTED (PAINTED P-X UNLESS NOTED OTHERWISE) OPEN TO STRUCTURE, METAL DECK INTERIOROTS X'-X"HEIGHT ABOVE FINISH FLOOR (AFF) AREA OF SPECIALTY LIGHTING, TBD BV-1: COLOR BLEND. (NOMINAL COURSE: 8/3h x 12"w x 3-1/2"d) 1/3 STAGGERED RUNNING BOND 1. REFER TO FLOOR PLANS FOR WALL ASSEMBLY TYPES AND TO ROOF PLANS FOR ROOF ASSEMBLY TYPES. SEE SHEET A0.10 FOR TYPES. 2. MASONRY: PROVIDE HORIZONTAL JOINTS AND LEDGER ANGLES AT FLOOR LEVELS OR AT MAX. 30'. PROVIDE VERTICAL JOINTS EVERY +/-28'. 3. PROVIDE STAINLESS STEEL DOWNSPOUTS FROM ROOFS GUTTERS. DOWNSPOUTS SHOULD BE LOCATED NEAR CORNERS. 4. CANOPY ROOFS SLOPED TO DRAIN TOWARDS COLUMNS. PROVIDE STAINLESS STEEL DOWNSPOUTS. 5. ALL MASONRY BELOW 2nd FLOOR LEVEL TO HAVE ANTI-GRAFFITI COATING. GENERAL NOTES: ELEVATIONS LEGEND BV1a MWP-1 MWP-1: METAL WALL PANEL SYSTEM. VERTICAL (CUSTOM COLOR PER ARCHITECT) EPEPOTS LEGEND: ROOF PLAN NOTES: 1. NOT ALL ROOF PENETRATIONS ARE SHOWN. COORDINATE WITH STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL ROOF PENETRATIONS. REFER TO SHEET ROOF PENETRATION DETAILS UNLESS NOTED OTHERWISE. 2. SEE HORIZONTAL ASSEMBLIES FOR ROOF TYPE DIAGRAMS. 3. LOADING OF CONSTRUCTION MATERIALS SHALL NOTE EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. 4. SEE HORIZONTAL ASSEMBLIES FOR ROOF TYPE ASSEMBLIES. 5. REFER TO WALL SECTIONS FOR ELEVATIONS OF ROOF STRUCTURE. SINGLE MEMBRANE ROOFING 1. SEE ELECTRICAL AND MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. 2. LIGHT FIXTURES AND MECHANICAL ELEMENTS ARE SHOWN FOR LOCATION ONLY AND MAY NOT SHOW ALL FIXTURES/ELEMENTS. SEE LIGHTING AND MECHANICAL DOCUMENTS FOR ALL INSTANCES AND FIXTURE TYPES. 3. FOR WALL MOUNTED FIXTURES, SEE ELEVATIONS FOR MOUNTING HEIGHTS. 4. SLOPED SURFACE WILL APPEAR LESS THAN TRUE LENGTH ON RCP DRAWINGS. SEE SECTIONS AND DETAILS FOR ACTUAL DIMENSIONS. 5. ALL CEILING HEIGHTS ARE FROM FINISHED FLOOR, UNLESS NOTED OTHERWISE. 6. DIMENSIONS ARE TO FACE OF FINISH, UNLESS NOTED OTHERWISE. GENERAL RCP NOTES date phase k e y p l a n revisions date project RE N T O N H I G H S C H O O L RE P L A C E M E N T 6/ 5 / 2 0 2 5 5 : 5 1 : 5 4 P M Au t o d e s k D o c s : / / 2 3 0 0 7 R e n t o n H S / 2 3 0 0 7 R e n t o n H S S i t e. r v t A10.03 SITE BUILDINGS - RR / CONCESSIONS T 4 2 5 . 2 0 4 . 2 3 0 0 RE N T O N S C H O O L D I S T R I C T DD SET 40 0 S . 2 N D S T R E E T , R E N T O N , W A 9 8 0 5 7 06/06/2025 23007 N O T F O R C O N S T R U C T I O N SCALE:1/8" = 1'-0"1FLOOR PLAN - RR & CONCESSIONS SCALE: 1/8" = 1'-0" 3ROOF PLAN - RR & CONCESSIONS SCALE: 1/8" = 1'-0" 4D ELEV CONCESSION - EAST 4A 4B SCALE: 1/8" = 1'-0" 2RCP - RR & CONCESSIONS SCALE: 1/8" = 1'-0" 5SECTION - RR / CONCESSIONS SCALE:1/4" = 1'-0" 6D INTERIOR ELEVATION CONCESSION S101A 6C6B6A CANOPY R-11 ROOF SLOPE 1/4" / 12 50'-0" 4' - 0 " A10.04 4C A10.04 4A A10.04 4B 5 A10.04 90'-0" 50 ' - 0 " HBHB E10e A-20e TYP. INTERIOR WALL TYP. EXTERIOR WALL 12" CONCRETE SLAB ON GRADE FIELD STORAGE S103A MAINTENANCE STORAGE S103B ELEC S103C S103A-2 S1 0 3 A - 1 S1 0 3 C - 1 S1 0 3 B - 1 S103B-2 HBHB METAL CANOPY ROLL UP DOOR HM DOOR DF BV1a 10 ' - 0 " BV1a TYP 12 ' - 0 " GUTTER / DS EAST ELEVATION OPPOSITE 5 A10.04 OTS OTS OTS WALL CONSTRUCTION TYPE -SEE WALL TYPES SHEET WHERE SHOWN, INDICATES FIRE RESISTANCE IN HOURS A 55 -2 b WALL NUMBER INDICATED ON WALL TYPES SHEET WALL FUNCTION (A = INTERIOR; E = EXTERIOR) WALL STRUCTURE AS NOTED IN WALL ASSEMBLY A55-2b WALL TAG WHERE OCCURS, TRIANGLE INDICATES ORIENTATION OF WALL ASSEMBLY: TRIANGLE IS THE RIGHT SIDE OF WALL TYPE SHOWN ON THE WALL ASSEMBLY SHEET. LEGEND INDICATES WALL CALLED OUT BY WALL TAG. SEE SHEET NOTES FOR ADDITIONAL INFORMATION. SHEET NOTES 1. CONDITIONS AND DETAILS MARKED "TYPICAL" SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. TYPICAL DETAILS NOT REFERENCED ON DRAWINGS APPLY UNLESS NOTED OTHERWISE BY SPECIFIC NOTES AND DETAILS. WHERE NO SPECIFIC DETAIL IS SHOWN, THE CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO THAT INDICATED FOR THE TYPICAL CONSTRUCTION OF THE PROJECT. 2. LOADING OF CONSTRUCTION MATERIALS SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. 3. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING WITH APPROPRIATE TRADES, DRAWINGS, AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. 4. PROVIDE ALL NECESSARY ANCHORAGE BLOCKING, BACKING, FRAMING FOR HANDRAILS, DOOR STOPS, CASEWORK, SHELVING, MIRRORS, WALL MOUNTED EQUIPMENT, AND ALL OTHER ITEMS AS REQUIRED FOR COMPLETE INSTALLATION. 5. CONFIRM ALL ROUGH OPENING DIMENSIONS FOR DOORS AND WINDOWS PRIOR TO COMMENCEMENT OF CONSTRUCTION. 6. UNLESS NOTED OTHERWISE, ENTIRE WALL ASSEMBLY OF ALL INTERIOR WALLS AND PARTITIONS SHALL EXTEND TO THE UNDRESIDE OF THE FLOOR DECK OR ROOF DECK ABOVE 7. WHERE A LENGTH OF WALL IS INTERSECTED BY PERPENDICULAR WALLS, WALL TYPE TO BE CONTINUOUS BETWEEN TAGS UNLESS NOTED OTHERWISE. 8. PROVIDE SOLID BLOCKING BETWEEN ROOF JOISTS WHERE WALL RUNS PERPENDICULAR TO ROOF JOISTS. GYPSUM BOARD TO TERMINATE AT ROOF JOISTS. 9. ALIGN FINISHES WHERE INDICATED. 10. SEE PLANS FOR LOCATIONS OF WRAPPED STRUCTURAL STEEL COLUMNS, SEE A0.10 FOR DETAILS * FOR SHAFT WALL STRUCTURE, DIMENSION INCLUDES 1" WALL PANEL. ** MASONRY DIMENSIONS ARE NOMINAL *** DIMENSIONS MAY BE FOR REFERENCE. ACTUAL STRUCTURAL THICKNESS IS PROVIDED BY THE STRUCTURAL ENGINEER METAL STUD*: a = 1-7/8" b = 2-1/2" c = 4" d = 6" e = 8" f = 10" g = 12" MASONRY** : a = na b = na c = 4" d = 6" e = 8" f = 10" g = 12" CONCRETE***: a = na b = na c = 4" d = 6" e = 8" f = 10" g = 12" h = 14" 5 A10.04 DS DS CONTINUOUS GUTTER BV1a BV-1: COLOR BLEND. (NOMINAL COURSE: 8/3h x 12"w x 3-1/2"d) 1/3 STAGGERED RUNNING BOND 1. REFER TO FLOOR PLANS FOR WALL ASSEMBLY TYPES AND TO ROOF PLANS FOR ROOF ASSEMBLY TYPES. SEE SHEET A0.10 FOR TYPES. 2. MASONRY: PROVIDE HORIZONTAL JOINTS AND LEDGER ANGLES AT FLOOR LEVELS OR AT MAX. 30'. PROVIDE VERTICAL JOINTS EVERY +/-28'. 3. PROVIDE STAINLESS STEEL DOWNSPOUTS FROM ROOFS GUTTERS. DOWNSPOUTS SHOULD BE LOCATED NEAR CORNERS. 4. CANOPY ROOFS SLOPED TO DRAIN TOWARDS COLUMNS. PROVIDE STAINLESS STEEL DOWNSPOUTS. 5. ALL MASONRY BELOW 2nd FLOOR LEVEL TO HAVE ANTI-GRAFFITI COATING. GENERAL NOTES: ELEVATIONS LEGEND BV1a MWP-1 MWP-1: METAL WALL PANEL SYSTEM. VERTICAL (CUSTOM COLOR PER ARCHITECT) LEGEND: GYPSUM BOARD CEILING PAINTED (PAINTED P-X UNLESS NOTED OTHERWISE) OPEN TO STRUCTURE, METAL DECK INTERIOROTS X'-X"HEIGHT ABOVE FINISH FLOOR (AFF) AREA OF SPECIALTY LIGHTING, TBD LEGEND: ROOF PLAN NOTES: 1. NOT ALL ROOF PENETRATIONS ARE SHOWN. COORDINATE WITH STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL ROOF PENETRATIONS. REFER TO SHEET ROOF PENETRATION DETAILS UNLESS NOTED OTHERWISE. 2. SEE HORIZONTAL ASSEMBLIES FOR ROOF TYPE DIAGRAMS. 3. LOADING OF CONSTRUCTION MATERIALS SHALL NOTE EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. 4. SEE HORIZONTAL ASSEMBLIES FOR ROOF TYPE ASSEMBLIES. 5. REFER TO WALL SECTIONS FOR ELEVATIONS OF ROOF STRUCTURE. SINGLE MEMBRANE ROOFING 1. SEE ELECTRICAL AND MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. 2. LIGHT FIXTURES AND MECHANICAL ELEMENTS ARE SHOWN FOR LOCATION ONLY AND MAY NOT SHOW ALL FIXTURES/ELEMENTS. SEE LIGHTING AND MECHANICAL DOCUMENTS FOR ALL INSTANCES AND FIXTURE TYPES. 3. FOR WALL MOUNTED FIXTURES, SEE ELEVATIONS FOR MOUNTING HEIGHTS. 4. SLOPED SURFACE WILL APPEAR LESS THAN TRUE LENGTH ON RCP DRAWINGS. SEE SECTIONS AND DETAILS FOR ACTUAL DIMENSIONS. 5. ALL CEILING HEIGHTS ARE FROM FINISHED FLOOR, UNLESS NOTED OTHERWISE. 6. DIMENSIONS ARE TO FACE OF FINISH, UNLESS NOTED OTHERWISE. GENERAL RCP NOTES date phase k e y p l a n revisions date project RE N T O N H I G H S C H O O L RE P L A C E M E N T 6/ 5 / 2 0 2 5 5 : 5 1 : 5 7 P M Au t o d e s k D o c s : / / 2 3 0 0 7 R e n t o n H S / 2 3 0 0 7 R e n t o n H S S i t e. r v t A10.04 SITE BUILDINGS - SITE STORAGE T 4 2 5 . 2 0 4 . 2 3 0 0 RE N T O N S C H O O L D I S T R I C T DD SET 40 0 S . 2 N D S T R E E T , R E N T O N , W A 9 8 0 5 7 06/06/2025 23007 N O T F O R C O N S T R U C T I O N SCALE:1/8" = 1'-0"3ROOF PLAN - SITE STORAGE SCALE: 1/8" = 1'-0" 1FLOOR PLAN - SITE STORAGE SCALE:1/8" = 1'-0"4AELEVATIONS - STORAGE BLDG - SOUTH SCALE:1/8" = 1'-0"4BELEVATION - STORAGE BLDG SCALE: 1/8" = 1'-0" 2RCP - SITE STORAGE SCALE:1/8" = 1'-0"5SECTION - SITE STORAGE SCALE:1/8" = 1'-0"4CELEVATIONS - STORAGE BLDG - NORTH A10.05 5B A10.05 5C A10.055D A10.05 5A BATTING CAGES 15 ' - 0 " E12e 70 ' - 0 " E12e 15 ' - 0 " 12" CONCRETE SLAB ON GRADE SYNTHETIC TURF 4 A10.05 STORAGE S102b BATTING S102 E11 12'-0"12'-0" 2'-0" S102-1 S102B-1 R-10 ROOF SLOPE 1/4/12 CHAIN LINK LID 10 ' - 0 " CHAIN LINK FENCE CHAIN LINK LID GUTTER / DS BV1a DS DS BV1a 10 ' - 0 " 10 ' - 0 " CHAIN LINK FENCE CHAIN LINK LID BV1a WALL CONSTRUCTION TYPE -SEE WALL TYPES SHEET WHERE SHOWN, INDICATES FIRE RESISTANCE IN HOURS A 55 -2 b WALL NUMBER INDICATED ON WALL TYPES SHEET WALL FUNCTION (A = INTERIOR; E = EXTERIOR) WALL STRUCTURE AS NOTED IN WALL ASSEMBLY A55-2b WALL TAG WHERE OCCURS, TRIANGLE INDICATES ORIENTATION OF WALL ASSEMBLY: TRIANGLE IS THE RIGHT SIDE OF WALL TYPE SHOWN ON THE WALL ASSEMBLY SHEET. LEGEND INDICATES WALL CALLED OUT BY WALL TAG. SEE SHEET NOTES FOR ADDITIONAL INFORMATION. SHEET NOTES 1. CONDITIONS AND DETAILS MARKED "TYPICAL" SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. TYPICAL DETAILS NOT REFERENCED ON DRAWINGS APPLY UNLESS NOTED OTHERWISE BY SPECIFIC NOTES AND DETAILS. WHERE NO SPECIFIC DETAIL IS SHOWN, THE CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO THAT INDICATED FOR THE TYPICAL CONSTRUCTION OF THE PROJECT. 2. LOADING OF CONSTRUCTION MATERIALS SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. 3. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING WITH APPROPRIATE TRADES, DRAWINGS, AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. 4. PROVIDE ALL NECESSARY ANCHORAGE BLOCKING, BACKING, FRAMING FOR HANDRAILS, DOOR STOPS, CASEWORK, SHELVING, MIRRORS, WALL MOUNTED EQUIPMENT, AND ALL OTHER ITEMS AS REQUIRED FOR COMPLETE INSTALLATION. 5. CONFIRM ALL ROUGH OPENING DIMENSIONS FOR DOORS AND WINDOWS PRIOR TO COMMENCEMENT OF CONSTRUCTION. 6. UNLESS NOTED OTHERWISE, ENTIRE WALL ASSEMBLY OF ALL INTERIOR WALLS AND PARTITIONS SHALL EXTEND TO THE UNDRESIDE OF THE FLOOR DECK OR ROOF DECK ABOVE 7. WHERE A LENGTH OF WALL IS INTERSECTED BY PERPENDICULAR WALLS, WALL TYPE TO BE CONTINUOUS BETWEEN TAGS UNLESS NOTED OTHERWISE. 8. PROVIDE SOLID BLOCKING BETWEEN ROOF JOISTS WHERE WALL RUNS PERPENDICULAR TO ROOF JOISTS. GYPSUM BOARD TO TERMINATE AT ROOF JOISTS. 9. ALIGN FINISHES WHERE INDICATED. 10. SEE PLANS FOR LOCATIONS OF WRAPPED STRUCTURAL STEEL COLUMNS, SEE A0.10 FOR DETAILS * FOR SHAFT WALL STRUCTURE, DIMENSION INCLUDES 1" WALL PANEL. ** MASONRY DIMENSIONS ARE NOMINAL *** DIMENSIONS MAY BE FOR REFERENCE. ACTUAL STRUCTURAL THICKNESS IS PROVIDED BY THE STRUCTURAL ENGINEER METAL STUD*: a = 1-7/8" b = 2-1/2" c = 4" d = 6" e = 8" f = 10" g = 12" MASONRY** : a = na b = na c = 4" d = 6" e = 8" f = 10" g = 12" CONCRETE***: a = na b = na c = 4" d = 6" e = 8" f = 10" g = 12" h = 14" LEGEND: GYPSUM BOARD CEILING PAINTED (PAINTED P-X UNLESS NOTED OTHERWISE) OPEN TO STRUCTURE, METAL DECK INTERIOROTS X'-X"HEIGHT ABOVE FINISH FLOOR (AFF) AREA OF SPECIALTY LIGHTING, TBD LEGEND: ROOF PLAN NOTES: 1. NOT ALL ROOF PENETRATIONS ARE SHOWN. COORDINATE WITH STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL ROOF PENETRATIONS. REFER TO SHEET ROOF PENETRATION DETAILS UNLESS NOTED OTHERWISE. 2. SEE HORIZONTAL ASSEMBLIES FOR ROOF TYPE DIAGRAMS. 3. LOADING OF CONSTRUCTION MATERIALS SHALL NOTE EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. 4. SEE HORIZONTAL ASSEMBLIES FOR ROOF TYPE ASSEMBLIES. 5. REFER TO WALL SECTIONS FOR ELEVATIONS OF ROOF STRUCTURE. SINGLE MEMBRANE ROOFING 1. SEE ELECTRICAL AND MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. 2. LIGHT FIXTURES AND MECHANICAL ELEMENTS ARE SHOWN FOR LOCATION ONLY AND MAY NOT SHOW ALL FIXTURES/ELEMENTS. SEE LIGHTING AND MECHANICAL DOCUMENTS FOR ALL INSTANCES AND FIXTURE TYPES. 3. FOR WALL MOUNTED FIXTURES, SEE ELEVATIONS FOR MOUNTING HEIGHTS. 4. SLOPED SURFACE WILL APPEAR LESS THAN TRUE LENGTH ON RCP DRAWINGS. SEE SECTIONS AND DETAILS FOR ACTUAL DIMENSIONS. 5. ALL CEILING HEIGHTS ARE FROM FINISHED FLOOR, UNLESS NOTED OTHERWISE. 6. DIMENSIONS ARE TO FACE OF FINISH, UNLESS NOTED OTHERWISE. GENERAL RCP NOTES BV-1: COLOR BLEND. (NOMINAL COURSE: 8/3h x 12"w x 3-1/2"d) 1/3 STAGGERED RUNNING BOND 1. REFER TO FLOOR PLANS FOR WALL ASSEMBLY TYPES AND TO ROOF PLANS FOR ROOF ASSEMBLY TYPES. SEE SHEET A0.10 FOR TYPES. 2. MASONRY: PROVIDE HORIZONTAL JOINTS AND LEDGER ANGLES AT FLOOR LEVELS OR AT MAX. 30'. PROVIDE VERTICAL JOINTS EVERY +/-28'. 3. PROVIDE STAINLESS STEEL DOWNSPOUTS FROM ROOFS GUTTERS. DOWNSPOUTS SHOULD BE LOCATED NEAR CORNERS. 4. CANOPY ROOFS SLOPED TO DRAIN TOWARDS COLUMNS. PROVIDE STAINLESS STEEL DOWNSPOUTS. 5. ALL MASONRY BELOW 2nd FLOOR LEVEL TO HAVE ANTI-GRAFFITI COATING. GENERAL NOTES: ELEVATIONS LEGEND BV1a MWP-1 MWP-1: METAL WALL PANEL SYSTEM. VERTICAL (CUSTOM COLOR PER ARCHITECT) date phase k e y p l a n revisions date project RE N T O N H I G H S C H O O L RE P L A C E M E N T 6/ 5 / 2 0 2 5 5 : 5 1 : 5 9 P M Au t o d e s k D o c s : / / 2 3 0 0 7 R e n t o n H S / 2 3 0 0 7 R e n t o n H S S i t e. r v t A10.05 SITE BLDG - BATTING CAGE T 4 2 5 . 2 0 4 . 2 3 0 0 RE N T O N S C H O O L D I S T R I C T DD SET 40 0 S . 2 N D S T R E E T , R E N T O N , W A 9 8 0 5 7 06/06/2025 23007 N O T F O R C O N S T R U C T I O N SCALE:1/8" = 1'-0"1FLOOR PLAN - BATTING CAGES SCALE:1/8" = 1'-0"3ROOF PLAN - BATTING CAGE SCALE:1/8" = 1'-0" 5D ELEVATIONS - SITE BATTING CAGES 5C5A 5B SCALE:1/8" = 1'-0"2RCP - BATTING CAGE SCALE: 1/8" = 1'-0" 4SECTION - BATTING CAGES 1" DIA. GROUND ROD K.O. 6" DIA. SUMP KNOCKOUT GALVANIZED PULL IRON (2 PLACES) 18" X 26" OR 26" X 26", 12" DEEP RECESS KNOCKOUT (2 PLACES) 8" X 16" KNOCKOUT (2 PLACES EA. SIDE WALL) BASE SECTION TOP RING 12"3'-0" 5'-0" 30" 5'-0"3'-0" 12" 7 32 4 8 6 5 1 12" 26" 36" 6" 5'-0" 3'-0" 4" 10" 17" 4" PRECAST 3'-0" X 5'-0" CONCRETE HANDHOLE. H20 FULL TRAFFIC LOADING COVER. UTILITY IDENTIFICATION TO READ "TELECOMMUNICATIONS" ON TOP OF COVER. RATED FOR H20 FULL TRAFFIC LOADING. COORDINATE LOCATIONS OF KNOCKOUTS WITH SUPPLIER. PROVIDE SEPARATE BASE FOR INTERCEPTING CONDUITS AS REQUIRED. TYPICAL LID FOR SECURE HANDHOLE. TYPICAL LID FOR UNSECURE HANDHOLE. 1 2 3 4 5 6 7 8 CONSTRUCTION NOTES FINISHED GRADE SLIP RESISTANT COVER CONDUITWASHED ROCK GASKET MASTIC COMPOUND CONCRETE HANDHOLE UNLESS NOTED OTHERWISE SHALL BE FOGTITE J11 OR 3030-LA WITH GALVANIZED STEEL LID OR EQUAL, SIZED AS REQUIRED PER NEC. 1'-0" 2 1/2" TYP GROUND LEAD, SUPPLIED BY OTHERS TRAVIS LID AND FRAME 1/2" PENTA HEAD BOLT NAME PLATE (EX: LT, TS, ITS) 1'-0" 2'-9" 6 7 /8 " 1 '-1 0 " 3 3/8" PROVIDE ADDITIONAL HANDHOLES FOR CCTV EQUIPMENT MOUNTING ACCESS AND ROUTING OF CCTV CABLES. COORDINATE EXACT ORIENTATION OF HANDHOLES WITH THE LIGHT FIXTURE HEAD AND CCTV EQUIPMENT. COORDINATE REQUIRED MOUNTING HOLES AND GROMMET LOCATIONS WITH THE CCTV AND LIGHT POLE MANUFACTURERS. MEDIA CONVERTER ENCLOSURE CCTV CAMERA MOUNT BOTTOM OF ENCLOSURE AT 17' AFG MOUNT BOTTOM OF CCTV AT 15' AFG STUB CONDUIT INTO BASE OF POLE GALV. LEVELING NUTS & WASHERS - GROUT BENEATH COVER & CONCRETE BASE GRADE 2'-6" MIN. BASE ABOVE GRADE 6" SQUARE LIGHT POLE HANDHOLE W/ TAMPERPROOF SCREWS HOLD DOWN NUTS & WASHERS W/COVER 1" CHAMFER 1" X 36" X 4" ANCHOR BOLTS - 4 EACH 1" CONDUIT FOR LIGHTING FIXTURE AND MEDIA CONVERTER CIRCUIT AND 1" CONDUIT FOR FIBER OPTIC CABLE. TO THE J11 TYPE 2 HANDHOLE TYPE 2 HANDHOLE, SEE SITE DRAWINGS TO NEXT LIGHT POLE TO NEXT LIGHT POLE 1" EACH FOR CCTV FIBER OPTIC, CCTV MEDIA CONVERTER POWER, AND LIGHTING CIRCUIT CONDUITS. SEE SITE DRAWINGS. #4 REBAR MINIMUM (TYPICAL) 6'-6" BELOW GRADE (MINIMUM) 24" DIA GENERAL NOTES 1. COORDINATE EXACT LOCATION AND ORIENTATION OF CCTV CAMERA AND MEDIA CONVERTER ENCLOSURE WITH THE CCTV INSTALLING CONTRACTOR. 2. LIGHT POLE SHOP DRAWING SUBMITTAL SHALL BE REVIEWED AND APPROVED BY THE DESIGN ENGINEER AND CCTV CONTRACTOR. 4" TOPSOIL REPLACE GRASS WITH SOD TO MATCH EXISTING LANDSCAPE EXISTING GROUND 8" BASE COURSE MATERIAL MARKER TAPE LAID ENTIRE LENGTH WITH 3" MIN. WIDTH 8" SLOPE DETERMINED BY CONTRACTOR BEDDING MATERIAL COMPACTED BACKFILL TO 95% - DENSITY SEE DRAWINGS FOR QUANTITY OF RACEWAYS 3" MIN 24" MINIMUM DEPTH AS REQUIRED TO AVOID EXISTING UTILITIES AND MEET CODE REQUIREMENTS 4'-0" 3'-6"(2) 2-TON LIFT ANCHORS 8" 1'-0" 3'-6" 4'-0" (2) 5/8" DIA. INSERTS 2'-0" LONG GALVANIZED "C" CHANNEL (1 EACH WALL) 8" DIA. SUMP 1" DIA. GROUND ROD KNOCKOUT GALVANIZED PULL/LIFT IRON (1 EACH CORNER) 12" X 18" KNOCKOUT (2 EACH WALL) 3'-2 1/2" 3 1/2" 3'-6" 4'-0" 1'-7 1/2" 1'-2" 1'-6" 4 1/2" 6" 8" DIA. SUMP 1" DIA. GROUND ROD HOLE 12" X 18" KNOCKOUT (2 EACH WALL) BASE NO. 444-B GALVANIZED PULL/LIFT IRON (1 EACH CORNER) 2'-0" LONG GALVANIZED "C" CHANNEL (1 EACH SIDE) TOP NO. 44-332P 5/8" DIA. LIFT INSERT (2 PLACES IN TOP) SPRING ASSISTED GALVANIZED DIAMOND PLATE DOOR W/ LOCKING LATCH OPTIONAL-NONSLIP DOOR 2-TON LIFT ANCHOR (2 PLACES IN TOP) 4'-0" 3'-6" 6" 4'-0"4'-0" 4'-0" 4'-0" 5'-2" 4'-0"32" 21" 28" 25" PADMOUNT NO. 44-2125 PADMOUNT NO. 44-2832 PADMOUNT NO. 45-2832 OPTIONAL TOPS NOTE: DESIGNED FOR 0 TO 5'-0" OF COVER PLAN VIEW SECTION AA SIDE VIEW NO. 332P SPRING ASSISTED GALVANIZED DIAMOND PLATE DOOR W/ LOCKING LATCH A A 1'-0" 8" 8"4'-0" 28" 32"4'-0" B D G F date phase k e y p l a n revisions date project A C E 9/ 1 2 / 2 0 2 5 5 : 1 1 : 0 3 P M C: \ U s e r s \ s b r o w n \ D o c u m e n t s \ L o c a l R e v i t M o d e l s \ R e n t o n H S - 51 5 2 4 0 1 0 5 \ 5 1 5 2 4 0 1 0 5 - 2 0 2 4 - T S C - E L E C - B L D G _ S e a b a s s . r v t E7.13 TELECOM SITE INFRASTRUCTURE DETAILS DD SET 06/06/2025 23007 RE N T O N H I G H S C H O O L RE P L A C E M E N T T 4 2 5 . 2 0 4 . 2 3 0 0 RE N T O N S C H O O L D I S T R I C T 40 0 S O U T H 2 N D S T R E E T , R E N T O N , W A 9 8 0 5 7 N O T F O R C O N S T R U C T I O N W T EXISTING PSE TRANSFORMER EXISTING PSE PULLBOX TO BE REMOVED EXISTING MAIN BOARD MSS-A (MAIN ELEC. RM) EXISTING PSE PRIMARY POWER TO BE REMOVED EXISTING PSE PRIMARY POWER TO BE REMOVED PANELS 1P4 SEC. 1, SEC. 2, & SEC.3, 1L3, 1XP9 (IDF AW 119)PANELS 1P5 SEC. 1 & SEC. 2, 1L4 (ELEC. AC108C) PANELS SWITCHBOARD (MSS-PAC), 2P1 SEC. 1 & SEC. 2, 2P2, 2PX3, 2PA, DIMMER RACKS #1-3 (ELEC. PA203) MCC 2M1 (MECH. PA202) PANELS 2P3 SEC. 1 & SEC. 2, 2L3 (CLOSET AW204) PANELS 2P4 SEC. 1 & SEC. 2, 2L4 (IDF AW213) PANELS 3P4 SEC. 1 & SEC. 2, 3L3 (CLOSET AW300) MCC 4M3 (MECH. AW402) NORMAL POWER (MH-N1) EMER. POWER (MH-E1) NORMAL POWER (MH-N2) EMER. POWER (MH-E2) PANELS 1L3, 1L4, 2L4, 2XL5 & MCC 4M4 PANELS 1L3 UP TO MSS-PAC & PANEL 2PX3 ON 2ND FLOOR. MSS-PAC & PANEL 2PX3 PANELS 1L1 & 1XL2 (ELEC AN100A) PANELS 2L1, 3L1, 1XL2 UP TO PNL 2L4UP TO MCC 4M4 UP TO PNL 2XL5 1 2 2 2 2 3 3 3 3 3 1 1222223 3 3 3 3 DEMOLITION NOTES EXISTING UTILITY POLE TO REMAIN. EXISTING UTILITY POLE TO BE REMOVED. EXISTING OVERHEAD POWER TO BE REMOVED. RETAIN EXISTING UNDERGROUND SYSTEMS CONDUIT AND CABLES. DEMOLISH EXISTING UNDERGROUND POWER CONDUITS AND CONDUCTORS. DEMOLISH EXISTING UNDERGROUND SYSTEMS CONDUITS AND CABLES. DEMOLISH EXISTING MANHOLE. EXISTING UNDERGROUND FEEDER IS CONFLICTING WITH NEW SCHOOL BUILDING FOOTPRINT. DEMOLISH EXISTING AND PROVIDE NEW FEEDER TO MAINTAIN THE EXISTING INDUSTRIAL ART BUILDING SERVICE DURING NEW BUILDING CONSTRUCTION. SEE SHEET E1.02 FOR ADDITIONAL INFORMATION. 1 2 3 APPROXIMATE MAIN SERVICE SWITCHBOARD LOCATION EXISTING MH-1B EXISTING MH-2B EXISTING MH-3B TO IDF ROOMEXISTING MH-1A EXISTING MH-3A 4 5 6 4 EXISTING MH-2A 6 5 7 8 8 8 68 5 8 7 8 7 8 7 8 7 8 5 8 68 APPROXIMATE MAIN SERVICE SWITCHBOARD LOCATION 4 4 M RETAIN EXISTING PSE METER INDUSTRIAL ART BUILDING CAFETERIA AND GYMASIUM date phase revisions date project RE N T O N H I G H S C H O O L RE P L A C E M E N T T 4 2 5 . 2 0 4 . 2 3 0 0 RE N T O N S C H O O L D I S T R I C T DD SET 40 0 S O U T H 2 N D S T R E E T , R E N T O N , W A 9 8 0 5 7 06/06/2025 23007 NOT F O R C O N S T R U C T I O N E1.01 EXISTING ELECTRICAL SITE PLANSCALE: 1" = 60'-0"1EXISTING ELECTRICAL SITE PLAN W DN TEXISTING PSE TRANSFORMER EXISTING MAIN BOARD MSS-A (MAIN ELEC. RM) MH MH MH 13 13 3 16 6 1 2 4 5 4 17 6 6 6 14 16 1 7 T18 14 19 13 16 T 12 14 5 MH APPROXIMATE MAIN SERVICE SWITCHBOARD LOCATION EXISTING MH-3B EXISTING MH-3A NORMAL POWER (MH-N1) EMER. POWER (MH-E1) 20 21 22 22 INDUSTRIAL ART BUILDING CAFETERIA AND GYMASIUM APPROXIMATE MAIN SERVICE SWITCHBOARD LOCATION M RETAIN EXISTING PSE METER 23 GENERAL NOTES 1.SEE ADDITIONAL GENERAL NOTES ON E0.01. CONSTRUCTION NOTES EXISTING UTILITY POLE TO REMAIN. PROPOSED OVERHEAD PRIMARY ROUTING. EXISTING UTILITY POLE TO REMAIN, NEW TRANSMISSION TO UNDERGROUND. PSE UNDERGROUND PRIMARY. PROPOSED PULLBOX FOR PSE PRIMARY SERVICE. PROPOSED PULLBOX FOR REFEEDING EXISTING PANELS. NEW UTILITY POLE. PRIMARY CONNECTION POINT DETERMINED BY PSE. NOT USED. PROPOSED NEW UTILITY TRANSFORMER (1 OF 3). PROPOSED NEW UTILITY TRANSFORMER (2 OF 3). PROPOSED NEW UTILITY TRANSFORMER (3 OF 3). NEW MAIN ELECTRICAL ROOM. PROPOSED ROUTING FOR SERVICE TO MAIN ELECTRICAL ROOM. PSE UNDERGROUND PRIMARY (ADDITIONAL PULLBOX AND ABOVE GROUND EQUIPMENT TBD BY PSE). SECONDARY UNDERGROUND ROUTING TO REFEED EXISTING BUILDING. PROVIDE TEMPORARY POWER SUPPLY TO EXISTING BUILDING MDB AS REQUIRED UNTIL DEMOLITION WORK IS COMPLETE. PROPOSED PULLBOX FOR PSE PRIMARY SERVICE WITH LOAD BREAKS. PROPOSED UTILITY TRANSFORMER FOR EXISTING BUILDING. PROPOSED ROUTING FOR GENERATOR. PROPOSED NEW TEMPORARY UNDERGROUND POWER FEEDER ROUTING. PROVIDE NEW POWER CONDUIT AND CONDUCTORS TO MATCH EXISTING FEEDER TO INDUSTRIAL ART BUILDING. SEE SHEET E1.01 FOR DEMOLITION WORK. PROPOSED NEW TEMPORARY UNDERGROUND SYSTEM FEEDER ROUTING. PROVIDE NEW SYSTEM CONDUIT AND CABLES TO MATCH EXISTING FEEDER TO INDUSTRIAL ART BUILDING. SEE SHEET E1.01 FOR DEMOLITION WORK. SPLICE AND EXTEND EXISTING FEEDER TO EXISTING INDUSTRIAL ART BUILDING. RETAIN EXISTING FEEDER TO CAFETERIA AND GYMNASIUM BUILDING. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 date phase revisions date project RE N T O N H I G H S C H O O L RE P L A C E M E N T T 4 2 5 . 2 0 4 . 2 3 0 0 RE N T O N S C H O O L D I S T R I C T DD SET 40 0 S O U T H 2 N D S T R E E T , R E N T O N , W A 9 8 0 5 7 06/06/2025 23007 NOT F O R C O N S T R U C T I O N E1.02 EXISTING/NEW ELECTRICAL SITE PLANSCALE: 1" = 60'-0"1EXISTING/NEW ELECTRICAL SITE PLAN 2 ES5.02 1 ES5.02 4 ES5.01 3 ES5.01 GENERAL NOTES 1.SEE ADDITIONAL GENERAL NOTES ON E0.01. CONSTRUCTION NOTES EXISTING UTILITY POLE TO REMAIN. PROPOSED OVERHEAD PRIMARY ROUTING. EXISTING UTILITY POLE TO REMAIN, NEW TRANSMISSION TO UNDERGROUND. PSE UNDERGROUND PRIMARY. PROPOSED PULLBOX FOR PSE PRIMARY SERVICE. PROPOSED PULLBOX FOR REFEEDING EXISTING PANELS. NEW UTILITY POLE. PRIMARY CONNECTION POINT DETERMINED BY PSE. PROPOSED ROUTING FOR CONCESSIONS BUILDING. PROPOSED NEW UTILITY TRANSFORMER (1 OF 3). PROPOSED NEW UTILITY TRANSFORMER (2 OF 3). PROPOSED NEW UTILITY TRANSFORMER (3 OF 3). NEW MAIN ELECTRICAL ROOM. PROPOSED ROUTING FOR SERVICE TO MAIN ELECTRICAL ROOM. PSE UNDERGROUND PRIMARY (ADDITIONAL PULLBOX AND ABOVE GROUND EQUIPMENT TBD BY PSE). SECONDARY UNDERGROUND ROUTING TO REFEED EXISTING BUILDING. PROPOSED PULLBOX FOR PSE PRIMARY SERVICE WITH LOAD BREAKS. PROPOSED UTILITY TRANSFORMER FOR EXISTING BUILDING. PROPOSED ROUTING FOR GENERATOR. PROPOSED ROUTING FOR STORAGE BUILDING. PROPOSED ROUTING FOR BATTING CAGE BUILDING. 1 2 3 1 2 4 3 5 16 6 17 7 6 8 9 10 5 4 2 ES5.01 1 ES5.01 11 12 13 10 11 14 15 T MH MH 515 16 4 16 17 MH 5 6 9 7 18 18 19 8 2 ES5.02 1 ES5.01 3 ES5.03 4 ES5.03 14 6 13 20 20 14 19 T 12 14 MH FPL1 AL1 HH 9 21 21 20 20 20 9 13 HH 19 20 4 ES5.02 3 ES5.02 DS DS DS DS DS DS DS DS DS DS DSDS DS DS DS DS DS DS DS DS DS DSDSDSDS DS DS DS DS DS DS DS DS DS DS DS DS DS DS T T T T T T TT T S 2 N D S T S 2 N D S T L O G A N A V E S L O G A N A V E S L O G A N A V E S S T O B I N S T S T O B I N S T L O G A N A V E S S H A T T U C K A V E S L A K E A V E S L A K E A V E S A I R P O R T W A Y A I R P O R T W A Y S 2 N D S T L A K E A V E S S T O B I N S T S T O B I N S T date phase revisions date project RE N T O N H I G H S C H O O L RE P L A C E M E N T T 4 2 5 . 2 0 4 . 2 3 0 0 RE N T O N S C H O O L D I S T R I C T DD SET 40 0 S O U T H 2 N D S T R E E T , R E N T O N , W A 9 8 0 5 7 06/06/2025 23007 NOT F O R C O N S T R U C T I O N E1.03 SCALE: 1" = 60'-0"1 NEW ELECTRICAL SITE PLAN NEW ELECTRICAL SITE PLAN