54-Musco Lighting Study.pdf
Renton High School Renton,WA Sales Representative: Tim Butz · Designed By: William Isiminger · Design No.: 237876I · September 12, 2025 Not to be reproduced in whole or part without the written consent of Musco Lighting. ©1981, 2025 Musco Sports Lighting, LLC. Sports Illustrated Stadium, Harrison, New Jersey, USA UBS Arena, Elmont, New York, USA Tottenham Hotspur FC Training Ground, Tottenham, London, UKIowa Women of Achievement Bridge, Des Moines, Iowa, USA PROJECT SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 Renton High School Renton,WA LIGHTING SYSTEM Structure/Fixture Summary Structure ID Structure Height Fixt. Attachment Ht.Fixture Qty Fixture Type Design Load Circuit A1 50'50'3 TLC-LED-900 2.64 kW C 16'1 TLC-BT-575 0.57 kW C A2 70'70'3 TLC-LED-900 2.64 kW C 70'4 TLC-LED-1200 4.68 kW B 16'1 TLC-BT-575 0.57 kW C 16'1 TLC-BT-575 0.57 kW B A3 70'70'4 TLC-LED-1200 4.68 kW B 16'1 TLC-BT-575 0.57 kW B B1-B2 50'50'5 TLC-LED-900 4.40 kW C 16'1 TLC-BT-575 0.57 kW C B3 70'70'2 TLC-LED-1200 2.34 kW B 70'2 TLC-LED-1500 2.82 kW B 70'2 TLC-LED-900 1.76 kW B 16'1 TLC-BT-575 0.57 kW B B4 70'70'4 TLC-LED-1200 4.68 kW B 70'2 TLC-LED-1500 2.82 kW B 16'1 TLC-BT-575 0.57 kW B C1 40'40'5 TLC-LED-900 4.40 kW C 16'1 TLC-BT-575 0.57 kW C C2 50'50'5 TLC-LED-900 4.40 kW C 16'1 TLC-BT-575 0.57 kW C C3-C4 70'70'2 TLC-LED-900 1.76 kW B 70'1 TLC-LED-1200 1.17 kW B 16'1 TLC-BT-575 0.57 kW B D1-D2 70'70'3 TLC-LED-900 2.64 kW B 70'2 TLC-LED-1200 2.34 kW B 16'2 TLC-BT-575 1.15 kW B F1 60'60'4 TLC-LED-1500 5.64 kW A 16'2 TLC-BT-575 1.15 kW A F2-F3 70'70'4 TLC-LED-1500 5.64 kW A 16'2 TLC-BT-575 1.15 kW A F4 60'60'4 TLC-LED-1500 5.64 kW A 16'2 TLC-BT-575 1.15 kW A 17 102 98.83 kW *Fixtures in this design have dimmed output values to meet design specific needs. Circuit Summary Circuit Description Design Load Fixture Qty A Footabll 27.16 kW 24 B Baseball 45.34 kW 46 C Softball 26.33 kW 32 Fixture Type Summary Type Circuit Source Avg. Wattage Avg. Lumens L90 L80 L70 Quantity TLC-BT-575 A LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 8 TLC-BT-575 B LED 5700K - 75 CRI 575W 52,130 >120,000 >120,000 >120,000 10 TLC-BT-575 C LED 5700K - 75 CRI 575W 52,651 >120,000 >120,000 >120,000 6 TLC-LED-1200 B LED 5700K - 75 CRI 1169W 149,502 >120,000 >120,000 >120,000 20 TLC-LED-1500 A LED 5700K - 75 CRI 1410W 181,000 >120,000 >120,000 >120,000 16 TLC-LED-1500 B LED 5700K - 75 CRI 1410W 181,000 >120,000 >120,000 >120,000 4 TLC-LED-900 B LED 5700K - 75 CRI 880W 104,000 >120,000 >120,000 >120,000 12 TLC-LED-900 C LED 5700K - 75 CRI 880W 100,190 >120,000 >120,000 >120,000 26 Single Fixture Amperage Draw Chart Driver SpeciĮcaƟons (.90 min power factor) Line Amperage Per Fixture (max draw) Single Phase Voltage 208 (60) 220 (60) 240 (60) 277 (60) 347 (60) 380 (60) 480 (60) TLC-LED-1500 8.4 7.9 7.3 6.3 5.0 4.6 3.6 TLC-LED-1200 6.9 6.5 6.0 5.2 4.2 3.8 3.0 TLC-LED-900 5.2 4.9 4.5 3.9 3.1 2.9 2.3 TLC-BT-575 3.3 3.2 2.9 2.5 2.0 1.8 1.5 *Amp draw based on 100% fixture output, consult design specific datasheet for adjusted amperage draw chart Light Level Summary Calculation Grid Summary Grid Name Calculation Metric Illumination Ave Circuits Fixture QtyAveMinMaxMax/Min Ave/Min Baseball (Infield)Horizontal Illuminance 51.48 40 68 1.71 1.29 B 46 Baseball (Outfield)Horizontal Illuminance 33.20 24 50 2.09 1.40 B 46 Football Practice Horizontal Illuminance 34.29 23 44 1.94 1.50 A 24 PL Cd Max Candela (by Fixture)12.83 5 24 5.13 2.73 A,B,C 102 PL Spill Horizontal 0.00 0 0 --A,B,C 102 PL Spill Max Vertical Illuminance Metric 0.00 0 0 --A,B,C 102 Road Cd Max Candela (by Fixture)224.20 0 1153 --A,B,C 102 Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. PROJECT SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 Renton High School Renton,WA Light Level Summary Calculation Grid Summary Grid Name Calculation Metric Illumination Ave Circuits Fixture QtyAveMinMaxMax/Min Ave/Min Road Spill Horizontal 0.00 0 0 --A,B,C 102 Road Spill Max Vertical Illuminance Metric 0.01 0 0 --A,B,C 102 Soccer Practice Horizontal Illuminance 34.28 23 44 1.94 1.50 A 24 Softball (Infield)Horizontal Illuminance 51.48 32 61 1.93 1.63 C 32 Softball (Outfield)Horizontal Illuminance 34.24 22 51 2.32 1.57 C 32 Taxiway Horizontal 0.00 0 0 --A,B,C 102 Taxiway Max Candela (by Fixture)6.78 0 28 --A,B,C 102 Taxiway Max Vertical Illuminance Metric 0.00 0 0 --A,B,C 102 Taxiway Boundary Cd Max Candela (by Fixture)47.64 0 362 --A,B,C 102 Taxiway Boundary Spill Horizontal 0.00 0 0 --A,B,C 102 Taxiway Boundary Spill Max Vertical Illuminance Metric 0.00 0 0 --A,B,C 102 Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 41 31 23 23 31 41 44 33 29 29 33 44 37 27 25 25 27 37 41 40 33 33 40 41 39 39 35 35 39 39 34 37 33 33 37 34 33 37 34 34 37 33 37 38 36 36 38 37 37 39 35 35 39 37 34 27 27 27 27 34 40 33 30 30 33 40 39 32 25 25 32 39 F1 F2 F3F4 10 10 20 20 30 30 40 40 50 50 40 40 30 30 20 20 10 10 11 0 ' 105' 11 0 ' 105' 11 0 ' 105' 11 0 ' 105' SCALE IN FEET 1 : 50 0'50'100' Equipment List For Areas Shown Structure Fixtures QTY STRUCTURE ID SIZE GRADE ELEVATION ABOVE FIELD LEVEL FIXTURE TYPE QTY/POLE THIS GRID OTHER GRIDS 2 F1 F4 60'-60'TLC-LED-1500 4 4 0 15.5'TLC-BT-575 2 2 0 2 F2-F3 70'-70'TLC-LED-1500 4 4 0 15.5'TLC-BT-575 2 2 0 4 Totals 24 24 0 Above Field Level is height of fixtures above area shown Renton High School Renton,WA Grid Summary Name:Football Practice Size:360' x 160' Spacing:30.0' x 30.0' Height:3.0' above grade Illumination Summary MAINTAINED HORIZONTAL FOOTCANDLES Entire Grid Guaranteed Average: 30 Scan Average:34.29 Maximum:44 Minimum:23 Avg/Min:1.50 Guaranteed Max/Min: 2.5 Max/Min:1.94 UG (adjacent pts):1.49 CU:0.65 No. of Points:72 FIXTURE INFORMATION Applied Circuits:A No. of Fixtures:24 Total Load:27.16 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 10 10 20 20 30 30 40 40 50 50 40 40 30 30 20 20 10 10 41 31 23 23 31 41 44 33 29 29 33 44 37 27 25 25 27 37 41 40 34 34 40 41 39 39 35 35 39 39 34 37 33 33 37 34 33 37 34 34 37 33 37 38 36 36 38 37 37 39 35 35 39 37 34 27 27 27 27 34 40 33 30 30 33 40 39 32 25 25 32 39 11 0 ' 105' 11 0 ' 105' 11 0 ' 105' 11 0 ' 105' F3 F2 F4 F1 SCALE IN FEET 1 : 50 0'50'100' Equipment List For Areas Shown Structure Fixtures QTY STRUCTURE ID SIZE GRADE ELEVATION ABOVE FIELD LEVEL FIXTURE TYPE QTY/POLE THIS GRID OTHER GRIDS 2 F1 F4 60'-60'TLC-LED-1500 4 4 0 15.5'TLC-BT-575 2 2 0 2 F2-F3 70'-70'TLC-LED-1500 4 4 0 15.5'TLC-BT-575 2 2 0 4 Totals 24 24 0 Above Field Level is height of fixtures above area shown Renton High School Renton,WA Grid Summary Name:Soccer Practice Size:360' x 180' Spacing:30.0' x 30.0' Height:3.0' above grade Illumination Summary MAINTAINED HORIZONTAL FOOTCANDLES Entire Grid Guaranteed Average: 30 Scan Average:34.28 Maximum:44 Minimum:23 Avg/Min:1.50 Guaranteed Max/Min: 2.5 Max/Min:1.94 UG (adjacent pts):1.49 CU:0.65 No. of Points:72 FIXTURE INFORMATION Applied Circuits:A No. of Fixtures:24 Total Load:27.16 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 A3 C3 D1 B3 B4 D2 C4 54 58 52 46 50 50 46 36 37 33 58 68 57 52 49 49 44 40 35 39 27 49 57 57 55 50 45 40 38 32 33 31 44 50 53 52 46 40 36 36 31 30 30 49 49 48 45 40 34 32 31 26 32 33 45 44 44 41 34 28 27 28 29 34 33 46 43 41 38 31 25 24 25 25 30 30 40 42 39 37 29 25 26 27 25 31 36 27 32 35 32 28 28 30 29 29 34 31 33 35 31 29 29 34 31 32 31 37 25 34 37 30 28 33 38 36 35 36 27 24 29 32 32 30 27 24 24 A2 70 ' 332' 29 8 ' 174' 55 ' 50' 37 ' 200' 20 0 ' 38' 61 ' 53' 19 3 ' 331' 30 1 ' 53' SCALE IN FEET 1 : 60 0'60'120' Equipment List For Areas Shown Structure Fixtures QTY STRUCTURE ID SIZE GRADE ELEVATION ABOVE FIELD LEVEL FIXTURE TYPE QTY/POLE THIS GRID OTHER GRIDS 1 A2 70'-70'TLC-LED-1200 4 4 0 70'TLC-LED-900 3*0 3 15.5'TLC-BT-575 2 1 1 1 A3 70'-70'TLC-LED-1200 4 4 0 15.5'TLC-BT-575 1 1 0 1 B3 70'-70'TLC-LED-1200 2 2 0 70'TLC-LED-1500 2 2 0 70'TLC-LED-900 2 2 0 15.5'TLC-BT-575 1 1 0 1 B4 70'-70'TLC-LED-1200 4 4 0 70'TLC-LED-1500 2 2 0 15.5'TLC-BT-575 1 1 0 2 C3-C4 70'-70'TLC-LED-1200 1 1 0 70'TLC-LED-900 2 2 0 15.5'TLC-BT-575 1 1 0 2 D1-D2 70'-70'TLC-LED-1200 2 2 0 70'TLC-LED-900 3 3 0 15.5'TLC-BT-575 2 2 0 8 Totals 50 46 4 *This structure utilizes a back-to-back mounting configuration Above Field Level is height of fixtures above area shown Renton High School Renton,WA Grid Summary Name:Baseball Size:Irregular 301'/398'/331' Spacing:30.0' x 30.0' Height:3.0' above grade Illumination Summary MAINTAINED HORIZONTAL FOOTCANDLES Infield Outfield Guaranteed Average: 50 30 Scan Average:51.48 33.20 Maximum:68 50 Minimum:40 24 Avg/Min:1.29 1.40 Guaranteed Max/Min:2 2.5 Max/Min:1.71 2.09 UG (adjacent pts):1.19 1.54 CU:0.78 No. of Points:25 102 FIXTURE INFORMATION Applied Circuits:B No. of Fixtures:46 Total Load:45.34 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 C1 C2 A1 B1 B2 535857595245443837403828 55615859554945443530333022 50525351484337353026263328 50555144383335332725293939 52554939322728282625324351 48473933282525262728364733 464236352926272934364443 384435342927303134364439 3735312827273434313538 40312626262835363532 383327303235424237 2831353941433936 2329384630 31' 13 7 ' 231' 10 6 ' 35' 40 ' 137' 31 ' 106' 23 1 ' 46' 23 ' A2 SCALE IN FEET 1 : 50 0'50'100' Equipment List For Areas Shown Structure Fixtures QTY STRUCTURE ID SIZE GRADE ELEVATION ABOVE FIELD LEVEL FIXTURE TYPE QTY/POLE THIS GRID OTHER GRIDS 1 A1 50'-50'TLC-LED-900 3 3 0 15.5'TLC-BT-575 1 1 0 1 A2 70'-70'TLC-LED-1200 4 0 4 70'TLC-LED-900 3*3 0 15.5'TLC-BT-575 2 1 1 3 B1-B2 C2 50'-50'TLC-LED-900 5 5 0 15.5'TLC-BT-575 1 1 0 1 C1 40'-40'TLC-LED-900 5 5 0 15.5'TLC-BT-575 1 1 0 6 Totals 37 32 5 *This structure utilizes a back-to-back mounting configuration Above Field Level is height of fixtures above area shown Renton High School Renton,WA Grid Summary Name:Softball Size:250'/250'/250' - basepath 60' Spacing:20.0' x 20.0' Height:3.0' above grade Illumination Summary MAINTAINED HORIZONTAL FOOTCANDLES Infield Outfield Guaranteed Average: 50 30 Scan Average:51.48 34.24 Maximum:61 51 Minimum:32 22 Avg/Min:1.63 1.57 Guaranteed Max/Min:2 2.5 Max/Min:1.93 2.32 UG (adjacent pts):1.26 1.55 CU:0.73 No. of Points:25 119 FIXTURE INFORMATION Applied Circuits:C No. of Fixtures:32 Total Load:26.33 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 10 10 20 20 30 30 40 40 50 50 40 40 30 30 20 20 10 10 F3 F2 F4 F1 A3 B3 C4 A2 C1 C2 A1B1 B2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 SCALE IN FEET 1 : 100 0'100'200' Renton High School Renton,WA Grid Summary Name:PL Spill Spacing:30.0' x 10.0' Height:3.0' above grade Illumination Summary MAINTAINED HORIZONTAL FOOTCANDLES Entire Grid Scan Average: 0.00 Maximum:0 Minimum:0 No. of Points:18 FIXTURE INFORMATION Applied Circuits:A,B,C No. of Fixtures:102 Total Load:98.83 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 10 10 20 20 30 30 40 40 50 50 40 40 30 30 20 20 10 10 F3 F2 F4 F1 A3 B3 C4 A2 C1 C2 A1B1 B2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 SCALE IN FEET 1 : 100 0'100'200' Renton High School Renton,WA Grid Summary Name:PL Spill Spacing:30.0' x 10.0' Height:3.0' above grade Illumination Summary MAINTAINED MAX VERTICAL FOOTCANDLES Entire Grid Scan Average: 0.00 Maximum:0 Minimum:0 No. of Points:18 FIXTURE INFORMATION Applied Circuits:A,B,C No. of Fixtures:102 Total Load:98.83 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 10 10 20 20 30 30 40 40 50 50 40 40 30 30 20 20 10 10 F3 F2 F4 F1 A3 B3 C4 A2 C1 C2 A1B1 B2 13 10 22 15 8 18 13 6 5 6 9 9 18 24 23 8 8 16 SCALE IN FEET 1 : 100 0'100'200' Renton High School Renton,WA Grid Summary Name:PL Cd Spacing:30.0' x 10.0' Height:5.0' above grade Illumination Summary MAINTAINED MAX CANDELA (PER FIXTURE) Entire Grid Scan Average: 12.83 Maximum:24 Minimum:5 No. of Points:18 FIXTURE INFORMATION Applied Circuits:A,B,C No. of Fixtures:102 Total Load:98.83 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 10 10 20 20 30 30 40 40 50 50 40 40 30 30 20 20 10 10 F3 F2 F4 F1 A3 C3 D1 B3 B4 D2 C4 A2 C1 C2 A1B1 B2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.02 0.02 0.02 0.01 0.01 0.01 0.00 0.00 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.000.010.010.010.010.010.010.010.010.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.00 SCALE IN FEET 1 : 200 0'200'400' Renton High School Renton,WA Grid Summary Name:Road Spill Spacing:30.0' x 10.0' Height:3.0' above grade Illumination Summary MAINTAINED HORIZONTAL FOOTCANDLES Entire Grid Scan Average: 0.00 Maximum:0 Minimum:0 Avg/Min:- Max/Min:- UG (adjacent pts):0.00 CU:0.00 No. of Points:78 FIXTURE INFORMATION Applied Circuits:A,B,C No. of Fixtures:102 Total Load:98.83 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 10 10 20 20 30 30 40 40 50 50 40 40 30 30 20 20 10 10 F3 F2 F4 F1 A3 C3 D1 B3 B4 D2 C4 A2 C1 C2 A1B1 B2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 0.04 0.05 0.03 0.02 0.02 0.02 0.01 0.01 0.02 0.01 0.00 0.00 0.00 0.01 0.01 0.00 0.010.030.030.030.020.020.030.030.020.010.020.010.010.000.000.000.020.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.00 SCALE IN FEET 1 : 200 0'200'400' Renton High School Renton,WA Grid Summary Name:Road Spill Spacing:30.0' x 10.0' Height:3.0' above grade Illumination Summary MAINTAINED MAX VERTICAL FOOTCANDLES Entire Grid Scan Average: 0.01 Maximum:0 Minimum:0 Avg/Min:- Max/Min:- UG (adjacent pts):0.00 CU:0.00 No. of Points:78 FIXTURE INFORMATION Applied Circuits:A,B,C No. of Fixtures:102 Total Load:98.83 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 10 10 20 20 30 30 40 40 50 50 40 40 30 30 20 20 10 10 F3 F2 F4 F1 A3 C3 D1 B3 B4 D2 C4 A2 C1 C2 A1B1 B2 7 5 6 0 0 0 3 3 0 0 1 18 20 35 384 769 909 878 693 565 596 529 443 347 573 545 404 200 39 124 138 91 28 260823102396360679911539766692585282251572252734440112618441155312171881571614214381433220 SCALE IN FEET 1 : 200 0'200'400' Renton High School Renton,WA Grid Summary Name:Road Cd Spacing:30.0' x 10.0' Height:5.0' above grade Illumination Summary MAINTAINED MAX CANDELA (PER FIXTURE) Entire Grid Scan Average: 224.20 Maximum:1153 Minimum:0 Avg/Min:- Max/Min:- UG (adjacent pts):0.00 CU:0.00 No. of Points:78 FIXTURE INFORMATION Applied Circuits:A,B,C No. of Fixtures:102 Total Load:98.83 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 F2F1 A3 C3 D1 B3 B4 D2 C4 A2 C1 C2 A1B1 B2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 SCALE IN FEET 1 : 150 0'150'300' Renton High School Renton,WA Grid Summary Name:Taxiway Boundary Spill Spacing:30.0' x 10.0' Height:3.0' above grade Illumination Summary MAINTAINED HORIZONTAL FOOTCANDLES Entire Grid Scan Average: 0.00 Maximum:0 Minimum:0 Avg/Min:- Max/Min:- UG (adjacent pts):0.00 CU:0.00 No. of Points:45 FIXTURE INFORMATION Applied Circuits:A,B,C No. of Fixtures:102 Total Load:98.83 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 F2F1 A3 C3 D1 B3 B4 D2 C4 A2 C1 C2 A1B1 B2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.01 0.01 SCALE IN FEET 1 : 150 0'150'300' Renton High School Renton,WA Grid Summary Name:Taxiway Boundary Spill Spacing:30.0' x 10.0' Height:3.0' above grade Illumination Summary MAINTAINED MAX VERTICAL FOOTCANDLES Entire Grid Scan Average: 0.00 Maximum:0 Minimum:0 Avg/Min:- Max/Min:- UG (adjacent pts):0.00 CU:0.00 No. of Points:45 FIXTURE INFORMATION Applied Circuits:A,B,C No. of Fixtures:102 Total Load:98.83 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 F2F1 A3 C3 D1 B3 B4 D2 C4 A2 C1 C2 A1B1 B2 0 0 0 16 9 10 16 23 11 19 20 19 22 4 9 15 21 21 20 16 8 7 36 5 4 16 24 27 27 4 3 12 2 3 3 3 7 42 205 64 215 290 283 220 362 SCALE IN FEET 1 : 150 0'150'300' Renton High School Renton,WA Grid Summary Name:Taxiway Boundary Cd Spacing:30.0' x 10.0' Height:5.0' above grade Illumination Summary MAINTAINED MAX CANDELA (PER FIXTURE) Entire Grid Scan Average: 47.64 Maximum:362 Minimum:0 Avg/Min:- Max/Min:- UG (adjacent pts):0.00 CU:0.00 No. of Points:45 FIXTURE INFORMATION Applied Circuits:A,B,C No. of Fixtures:102 Total Load:98.83 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.000.00 SCALE IN FEET 1 : 50 0'50'100' Renton High School Renton,WA Grid Summary Name:Taxiway Spacing:30.0' x 10.0' Height:6.5' above grade Illumination Summary MAINTAINED HORIZONTAL FOOTCANDLES Entire Grid Scan Average: 0.00 Maximum:0 Minimum:0 Avg/Min:- Max/Min:- UG (adjacent pts):0.00 CU:0.00 No. of Points:13 FIXTURE INFORMATION Applied Circuits:A,B,C No. of Fixtures:102 Total Load:98.83 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.000.00 SCALE IN FEET 1 : 50 0'50'100' Renton High School Renton,WA Grid Summary Name:Taxiway Spacing:30.0' x 10.0' Height:6.5' above grade Illumination Summary MAINTAINED MAX VERTICAL FOOTCANDLES Entire Grid Scan Average: 0.00 Maximum:0 Minimum:0 Avg/Min:- Max/Min:- UG (adjacent pts):0.00 CU:0.00 No. of Points:13 FIXTURE INFORMATION Applied Circuits:A,B,C No. of Fixtures:102 Total Load:98.83 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 0 0 0 0 0 0 28 17 4 8 23 34 SCALE IN FEET 1 : 50 0'50'100' Renton High School Renton,WA Grid Summary Name:Taxiway Spacing:30.0' x 10.0' Height:6.5' above grade Illumination Summary MAINTAINED MAX CANDELA (PER FIXTURE) Entire Grid Scan Average: 6.78 Maximum:28 Minimum:0 Avg/Min:- Max/Min:- UG (adjacent pts):0.00 CU:0.00 No. of Points:13 FIXTURE INFORMATION Applied Circuits:A,B,C No. of Fixtures:102 Total Load:98.83 kW Pole location(s)dimensions are relative to 0,0 reference point(s) Guaranteed Performance:The ILLUMINATION described aboveis guaranteed per your Musco Warranty document. Field Measurements:Individual field measurements may varyfrom computer-calculated predictions. Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. EQUIPMENT LAYOUT Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC.ENGINEERED DESIGN By: William Isiminger • File #237876I • 12-Sep-25 Renton High School Renton,WA Football Practice 360' x 160' 10 10 20 20 30 30 40 40 50 50 40 40 30 30 20 20 10 10 F3 F2 F4 F1 Soccer Practice 360' x 180'(0.00', 0.00', -0.02') Baseball Irregular A3 C3 D1 B3 B4 D2 C4 A2 (72.14', 247.41', 0.00') Softball 250'/250'/250' - basepath 60' C1 C2 A1B1 B2 (- 2 7 . 4 2 ' , 2 8 4 . 9 8 ' , - 0 . 0 2 ' ) (0.00', 0.00', 0.00') SCALE IN FEET 1 : 200 0'200'400' Pole location(s)dimensions are relative to 0,0 reference point(s) Equipment Layout INCLUDES:· Baseball· Football Practice· Soccer Practice· Softball Electrical System Requirements:Refer to AmperageDraw Chart and/or the "Musco Control System Summary"for electrical sizing. Installation Requirements:Results assume ± 3%nominal voltage at line side of the driver and structureslocated within 3 feet (1m) of design locations. Equipment List For Areas Shown Structure Fixtures QTY STRUCTURE ID SIZE GLOBAL ELEVATION ABOVE GLOBAL LEVEL FIXTURE TYPE QTY/POLE 1 A1 50'-50' 15.5' TLC-LED-900 TLC-BT-575 3 1 1 A2 70'- 70' 70' 15.5' TLC-LED-1200 TLC-LED-900 TLC-BT-575 4 3* 2 1 A3 70'-70' 15.5' TLC-LED-1200 TLC-BT-575 4 1 3 B1-B2 C2 50'-50' 15.5' TLC-LED-900 TLC-BT-575 5 1 1 B3 70'- 70' 70' 70' 15.5' TLC-LED-1200 TLC-LED-1500 TLC-LED-900 TLC-BT-575 2 2 2 1 1 B4 70'- 70' 70' 15.5' TLC-LED-1200 TLC-LED-1500 TLC-BT-575 4 2 1 1 C1 40'-40' 15.5' TLC-LED-900 TLC-BT-575 5 1 2 C3-C4 70'- 70' 70' 15.5' TLC-LED-1200 TLC-LED-900 TLC-BT-575 1 2 1 2 D1-D2 70'- 70' 70' 15.5' TLC-LED-1200 TLC-LED-900 TLC-BT-575 2 3 2 2 F1 F4 60'-60' 15.5' TLC-LED-1500 TLC-BT-575 4 2 2 F2-F3 70'-70' 15.5' TLC-LED-1500 TLC-BT-575 4 2 17 Totals 102 Single Fixture Amperage Draw Chart Driver SpeciĮcaƟons (.90 min power factor) Line Amperage Per Fixture (max draw) Single Phase Voltage 208 (60) 220 (60) 240 (60) 277 (60) 347 (60) 380 (60) 480 (60) TLC-LED-1500 8.4 7.9 7.3 6.3 5.0 4.6 3.6 TLC-LED-1200 6.9 6.5 6.0 5.2 4.2 3.8 3.0 TLC-LED-900 5.2 4.9 4.5 3.9 3.1 2.9 2.3 TLC-BT-575 3.3 3.2 2.9 2.5 2.0 1.8 1.5 *Amp draw based on 100% Įxture output, consult design speciĮc datasheet for adjusted amperage draw chart *This structure utilizes a back-to-back mounting configuration Above Global Level is height of fixtures above design (0,0,0)