Loading...
HomeMy WebLinkAbout10-09-2025 - Addendum No 2Addendum No.2 Maplewood Sidewalk Rehabilitation 0 CAG-25-290 Date of Issue: October 9, 2025 Bid Due Date: October 14, 2025 (NO CHANGE) Date of Bid Opening: October 17, 2025 (CHANGED FROM DATE IN CALL FORBIDS) ATTENTION: ALL BIDDERS AND PLAN HOLDERS: The Bid Documents for the above -named project are modified as described below. Bidders shall take this Addendum into consideration when preparing and submitting their bids. Bidders shall attach this addendum to their copy of the Contract Documents, and shall acknowledge receipt of this Addendum on the Proposal Signature Page. A Proposal may be considered irregular and may be rejected if the receipt of Addenda is not acknowledged. A_ Proposal will be considered irregular and will be reiected if the Schedule of Prices included in this Addendum is not comoleted and submitted with the Proposal THE CONTRACT DOCUMENTS ARE MODIFIED AS FOLLOWS: 1. VOLUME II - PLANS Sheet DM-01 has been revised to show the 8" diameter storm drainage pipe removed per SP 7-08.3(2) J and to show the remaining pipes to be abandoned per SP 9-03.22. 2. SPECIAL PROVISIONS Section 2-02.4 has been revised to match Sheet DM-01 for installing a plug on existing valve and removing the existing valve box. ALL OTHER REQUIREMENTS OF THE CONTRACT DOCUMENTS REMAIN IN EFFECT. CITY F RENTON Robert M. Hanson, P.15. Transportation Design Manager Maplewood Sidewalk Rehabilitation Page 1 of 1 ADDENDUM NO, 2 October 9, 2025 ADJUST EXISTING MANHOLES. CLEANOUT, AND CATCH BASINS TO FINISHED GRADE (TYP) TRIM EXISTING HEDGE AS """" - PRES11 ERVE AND PROTECT PRESERVE AND PROTECT EXISTING NECESSARY FOR E%ISTING BRICK WALLS POWER POLE AND CONDUIT CONSTRUCTION ADD ANO COLUMNS PRESERVE AND PROTECT INSTALL 40 lF NGPE F P- I� PRESERVE AND PROT -�, a O f \ -// OVERH OC=WAVIM EXISTING TREE ---- �I EXISTING POWER POLE I AND CONDUIT '� O' + f s. ' / — - SE STH ST F— A <F PCPLA,,E EXISTING SGN MTV] MJTCD PRESR L AI PDTEC T �� W11-2 40 SbN (PEDESTRIAN SIGN) EXISTING MONUMENTPOST PER CDR SN"<<[� 1T 5 ON SHEET 5 ANDNREPLACEE NOTE HINISHEDCGRADEtO I)s l`} NEIGHBORHOOD WATCH SIGNWTH IN S� bA KIND 3009 T "� PRESERVE AND PROTECT REMOVE EXISTING CATCH TE .r � EXISTING MONUMENT. ADJUST BASIN _. C CASING TO FINISHED GRADE REPLACE EXISTING SIGN WiH MUTCD STO SIGN REMOVE ABANDONED WATER R1-2 (25 MPH SIGN) VALVE BOXES POST PER COR PLAN 129 ADJUST EXISTING WATER / \ METER BOXES TO FINISHED GRADE (TYP) REPLACE EXISTING MONUMENT REMOVE EXISTING CB EXISTING CB TO BE REPLACED PRESERVE AND PROTECT EXISTING POWER POLE AND GUY POLE REFER TO TRAFFIC CONTROL PLAN SHEETS FOR PROJECT STAGING LIMITS. 5 Know what's below. Call before you dig. n DazD NO PROTECT EXISTING ¢ GUY POLE AND HEDGE TING STREETSIGN WTH COB STD 129 SEE NOTE 5 ON SHEET 5 �+ PRESERVE AND PROTECT EXISTING HEDGE ;_-- 4 --- SCALE: 1" = 30' 30 13 O 30 80 T CONTOUR INTERVAL - 1' .,-- LEGEND \ REMOVE EXISTING D" CONIC PER _ 025 ASCOT SP ) O&3(2)J ASPHALT ROAD, SIDEWALK. DRIVEWAY AND REPLACE W/ R" DI & CURBING TO BE REMOVED ADJUST EXISTING WATER VALVE BOXES TO FINISHED GRADE (TIP) IREMOVE AND REPLACE EXISTING FIRE (HYDRANT (RETURN EX FIRE HYDRANT TO SHOP To BE USED FOR PARTS) PLUG Mal) ON EXISTING VALVE (BY REMOVE EXISTING VALVE BOX '•.NOON EXISTING SO r 025 WSDOT SP 9-03.22 REMOVE \� EPAVEMENT, & CUR SIDEWALK CURBING PRESERVE TREE PROTECT EXISTING TREE INSTALL 75 ITS NGPE FENCE �a I - \ BUSHEXISTING �rxce� BUSH BASIN INSERT PER COR STD SEE DETAIL THIS SHEET (TIP) REGRADE AND REPLACE PORTIONS/ OF EXISTING SIDEWALKS & DRIVEWAYS (TYP) 31 REMOVE ABANDON WATAVALVE \ - PRESERVE AND PROTECT EXISTINNG POWER POLE AND GUY POLE - PRESERVE AND PROTECT EXISTING SSMH 0 ADOENOUM Fz 10/s/f0z5 SARI SURVEYED: pl CITY OF RENTON ����(� G F DRAWINGNo. DMA DRAMBY!" ®F�a,ywRAwq.�BPo,.saal®I®10r1 CITY OF RENTON CITYWIDE WALKWAY IMPROVEMENTS/ PRaEOTNo.TED4004205 DESKaN BY: l0 B ry �v Public Works Ceparlment ,,. MAPLEWOOD SIDEWALK REHABILITATION & WWW.esmciWl.cam0 iNSTRUCa:lon Oeisbn FED Am NO. NA PROM MGY: R! APPROVED FOR GONSTRUC➢ON DATE: O➢ $ ' Rb; PROM MGR. Ia P"::.".".�.""' o „.,..b.:.�«.. DEMOLITION PUN NUMBER REVURON DESCRIPTION BY APR. DATE %9NAL FILE: DMZ1.6" ESMEJOB f215-009-025 ee DATB: CITY OF RENTON CONTRACT NO.CAG-25-290 SHEET ND.�oF� 2-02.4 Measurement Section 2-02.4 is supplemented with the following: Measurement for "Sawcutting" shall be by the horizontal length of the cut multiplied by the depth in inches. Unit of measurement shall be each "Remove Hydrant and Salvage". Payment shall be made for costs related to removal of hydrant fittings back to the water main, and installing a plug on existing valve and removing the existing valve box. All items noted for removal, abandonment, relocation, or salvage to which other Bid items do not apply shall be considered included, but not limited to, the items shown on the Plans and those specified herein. Saw cutting, demolition, haul, and disposaUsalvage of materialsto which this Bid item applies shall also be considered incidental. Remove Hydrant and Salvage will be measured by lump sum. 2-02.5 Payment Section 2-02.5 is supplemented with the following: Payment for "Sawcutting' shall be by the Contract unit bid price per inch -foot, which payment shalt be considered full compensation for all tools, equipment, labor, materials, and incidentals required to complete this work as specified herein. This bid item pertains to the sawcutting of asphalt and concrete pavement of at[ depths. "Remove Hydrant and Salvage", each. 2-03 ROADWAY EXCAVATION AND EMBANKMENT 2-03.1 Description Section 2-03.1 is supplemented with the following: This work shall also consist of potholing existing underground utilities as designated by the Engineer and shown on the Plans, regardless of size. The Contractor shall perform exploratory excavations as required to collect as -built utility information. Potholing includes all work necessary to determine the position of the underground utility including pavement removal, excavation and backfill if appropriate. This work is considered incidental to the bid item for "Pothole Existing Utility". The Contractor shall verify the depth and location of existing underground utilities. The Contractor shall allow the Engineer one week to allow for minor design modifications when needed. Upon completion of excavation, existing backfill material can be used for temporary restoration. Potholing shall be performed by a VactorTruck, hand tools, or small excavator. 47