HomeMy WebLinkAboutApproved_Building_6_Site_&_Drainage_Plan_20250818_V2TACOMA CT NEUNIT 1940-A UNIT 1940-C UNIT 1640 UNIT 1640 BLDG. 6 1316 15 14 ROW 1ROAD A21008 DESIGN 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING SURVEYING BUILDING 6 7/29/25 LEGAL DESCRIPTION TYPICAL CLEANOUT CONFIGURATION GENERAL NOTES: 1.CLEANOUTS FOR UNDERDRAIN, FOOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET, AT EVERY 90 DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE, AND AT EACH END OF AN UNDERDRAIN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE. CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES. 2.ALL FITTINGS SHALL BE SOIL TIGHT. 3.CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF BIORETENTION PONDING WHERE POSSIBLE. 4.CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY. DESIGN PONDING ELEVATION SOIL TIGHT 45° BEND EXTEND CLEANOUT RISER 2" ABOVE DESIGN PONDING ELEVATION OR PER PLAN 4" STREAMBED COBBLES PER WSDOT 9-03.11(2) SOIL TIGHT COUPLER UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE, SEE NOTE 1 WYE MECHANICAL PLUG OR CONTINUED CONNECTION FERNCO GASKETED QUIK CAP OR SIMILAR CAST IRON FRAME AND COVER, SEE NOTE 3 CLEANOUT RISER, SEE NOTE 2 PAVED AREA (TYP.) TO OVERFLOW STRUCTURE OR STORM MAIN CLEANOUT RISER LOCATED WITHIN BIORETENTION PONDING AREA NOTES: 1.DIAMETER TO BE 6-INCHES MINIMUM PRIVATE, 8-INCHES MINIMUM PUBLIC. UNDERDRAIN PIPE PER STD. PLAN 262.10. 2.CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE. 3.FRAME AND COVER SHALL BE EJ PRODUCTS 3675Z1PT AND 3675APT OR APPROVED EQUAL. COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED "STORM" OR DRAIN". 4.FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF BIORETENTION PONDING AREA, POUR 8" THICK, 2'x2' SQUARE CONCRETE COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI. CLEANOUT RISER, SEE NOTE 2 FRAME SECTION 10-1/2" DIA 4" 5/8"9" DIA 15" DIA 8-1/8" DIA 8-13/16" DIA 5/8" COVER SECTION MADE INUSA 1" PLAN VIEW PROD NO.3/4" FLAT FACE GOTHIC 2) 3/8"-16 SS SOCKET HEAD CAP SCREW (ALLENHEAD) W/WSHRS ON A 8" DIA BOLT CIRCLE 1) OPENPICKHOLE 12"12"4" COMPACTED SAND OR GRAVEL BACKFILL FOR DRAINS PER WSDOT 9-03. 12(4)8" CLASS "B"ASPHALT, SEE NOTE 4 STORM SYSTEM CLEANOUT STD. PLAN - 226.00 PUBLIC WORKS DEPARTMENTAPPROVED: DATEMartin Pastucha Public WorksAdministrator UNLESS OTHERWISENOTED, DRAWINGISNOT TO SCALE (NTS)DocuSign Envelope ID: 3B1B34D3-7E0A-476C- ADB3-4329FFE0C108 8/13/2020 | 8:48 PLAN VIEW OF PARCEL TO STORM DRAINSYSTEMRIGHT- OF-WAYGENERAL NOTES:1.INFILTRATION TRENCHES LIMITED TO ROOF RUNOFF FROM SINGLE-FAMILY OR DUPLEX HOMES OR TO CONTROL BASEMENT FLOODING. CONSULT WA DEPARTMENT OF ECOLOGY REGULATIONS FOR UNDERGROUND INJECTION CONTROL PROGRAM (UIC) FOR OTHER TYPES OF RUNOFF MANAGEMENT.2.IMPERVIOUS AREAS LARGER THAN 10,000 SF AND NON-NATIVE PERVIOUS AREAS LARGER THAN 35,000 SF MAY REQUIRE LARGER PIPE AND SHOULD BE DESIGNED BY A CIVIL ENGINEER.3.THE PERFORATED PIPE MAY NOT BE PLACED IN A CRITICAL AREA BUFFER OR ON SLOPES STEEPER THAN 25%.4.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.24" MIN.18" MIN.MIN. 1' ABOVE SEASONAL HIGH GROUNDWATER TABLE 6" MIN.3/4" - 11/2" WASHED DRAIN ROCK OR GRAVEL BACKFILL FOR DRYWELLS PER WSDOT STD.SPECIFICATION SECTION 9-03.12( 5)NON-WOVEN GEOTEXTILE FOR SEPARATION ON TOP AND SIDES OF TRENCH PER WSDOT SPECIFICATIONS SECTION 9-33.2(1) TABLE 3 COMPACTED TOPSOIL OR OTHER CLEAN FILL 6" DIA. MIN.PERFORATED PVC,SDR 35 PER ASTM D3034 10' MIN. LEVEL TRENCH WITH PERFORATED PIPE, SEE NOTE 1 DOWNSPOUT WITH CLEANOUT FILTER, SEE DETAIL ASECTION A NOTES:1.TRENCH LENGTH TO BE 10 FEET IN LENGTH FOR EVERY 5,000 SF OF CONTRIBUTING IMPERVIOUS SURFACE, OR 35,000 SF OF NON-NATIVE PERVIOUS SURFACE, OR PORTION THEREOF. 5' MIN. 5' MIN.TO STORM DRAIN SYSTEM 5' MIN. 5' MIN. A DOWNSPOUT WITH CLEANOUT FILTER, SEE DETAIL 10' MIN. LEVEL TRENCH WITH PERFORATED PIPE, SEE NOTE 1 CONFIGURATION ON FLAT GROUND CONFIGURATION ON SLOPING GROUND UNDISTURBED NATIVE SOIL CLEANOUT PER STD. PLAN 226. 00 CLEANOUT PER STD. PLAN 226. 00 FILTER SCREEN 2'-5' TO GROUND SOLIDS/ LEAVES TYPICAL DOWNSPOUT FILTER DETAIL FOOTING DRAIN BYPASS CLEANOUT PER STD. PLAN 226. 00 PERFORATED STUB- OUT CONNECTION PUBLIC WORKS DEPARTMENT APPROVED:DATEMartin Pastucha Public Works AdministratorUNLESS OTHERWISE NOTED, DRAWINGISNOTTO SCALE ( NTS)STD. PLAN - 263. 40 DocuSign Envelope ID: A9707D3B-A0EF-441F-8140- 2CDB48E878CA 11/2/2020 | 1:04 PM