HomeMy WebLinkAbout2025-10-10 - Lindbergh High School Field Improvements - 25B121-01 - 5228_Compressive Strength of Concrete_000008Specimen Number Test Age Days Test Date Field / Lab Cure Days Average Cylinder Diameter (in) Cylinder Area (in²) Max Load (lbs) Strength (psi) Fracture Type Break Remark Capping Method 8-1 7 10/17/25 3 / 4 4.00 12.57 47,064 3,740 2 U 8-2 28 11/07/25 3 / 25 8-3 28 11/07/25 3 / 25 8-4 28 11/07/25 3 / 25 8-5 56 H 12/05/25 3 / 53 Test Age Average Strengths (psi): 7 Day - 3740 Tested By: Paul Fuentes (1) Checked In : 10/13/2025 (1,2,3,4,5) Capping Methods U: Unbonded Caps (ASTM C1231) Set #:8 Specimen Size:4" X 8" Specimens In Set:5 Truck / Ticket #:1149 / 1257830 Contractor:Neeley Construction and JS Scott Technician:Mike Currie Cast By:Mike Currie Date Cast:10/10/25 Sampled From:Chute Placement Method:Pump Sample Details Batched:09:11 PDT Sampled:10:15 PDT Cast:10:20 PDT Truck Empty:10:40 PDT Placement Time:89 (min) Placement Location:Building Exterior - Other Location Details:SW corner site stairs and field lighting vault slab Sample Location / Notes:Site stairs Batch Log Strength:4000 (psi) Air:3.5 - 6.5 (%) Slump:4 - 6 (in) Specifications Supplier:Miles Plant:202 Sample Condition: Mix Design:1250AFG On-Site Admixtures: 312.00 Gal Water, gals. (11 yd³), 5350.00 LB Cement, lbs. (11 yd³), 1365.00 LB Flyash, lbs. (11 yd³), 14020.00 LB Sand (11 yd³), 3840.00 LB AGG 3/8 (11 yd³), 16800.00 LB AGG 7/8 (11 yd³), 110.00 Oz AEA-Air Entraining Admixture (11 yd³), 268.00 Oz Glenium 7500 S.P. (11 yd³) Location Field Measurements Plastic Unit Weight: Air Content:4.6 (ASTM C231) Load Volume:11.00 (yd³) Weather:Overcast/Showers Slump (in):4-1/4 (ASTM C143) Air Temperature (F):50 Concrete Temp (F):67 (ASTM C1064) Lab Test Results Testing Lab: Burlington, 777 Chrysler Drive, Burlington, WA, 98233 General Remarks Concrete was placed via placing boom pump truck and properly consolidated by screeding. Attachments Sample #Name Description 5228 20251010_103841.jpg As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Page 1 of 1 Client: Renton School District No. 403 Renton, WA 98057 300 SW 7th St Project: Lindbergh High School Field Improvements 25B121-01 (Bldg Permit: B25002218) Renton, WA 98059 16426 128th Avenue Southeast Compressive Strength of Concrete Test Method: ASTM C 39 Sample: 5228 Sample 5228 Report #: CC-000008-00 Burlington 777 Chrysler Drive Burlington, WA 98233 Phone: (360) 755-1990 Report Date: 10/17/2025 11:46 Page 1 of 2 As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Page 1 of 0 Client: Renton School District No. 403 Renton, WA 98057 300 SW 7th St Project: Lindbergh High School Field Improvements 25B121-01 (Bldg Permit: B25002218) Renton, WA 98059 16426 128th Avenue Southeast Compressive Strength of Concrete Test Method: ASTM C 39 Sample 5228 Report #: CC-000008-00 Burlington 777 Chrysler Drive Burlington, WA 98233 Phone: (360) 755-1990 Report Date: 10/17/2025 11:46 Page 2 of 2