Loading...
HomeMy WebLinkAbout2025-10-13 - Lindbergh High School Field Improvements - 25B121-01 - 5241_Compressive Strength of Concrete_000009Specimen Number Test Age Days Test Date Field / Lab Cure Days Average Cylinder Diameter (in) Cylinder Area (in²) Max Load (lbs) Strength (psi) Fracture Type Break Remark Capping Method 9-1 7 10/20/25 1 / 6 4.00 12.57 47,151 3,750 2 U 9-2 28 11/10/25 1 / 27 9-3 28 11/10/25 1 / 27 9-4 28 11/10/25 1 / 27 9-5 56 H 12/08/25 1 / 55 Test Age Average Strengths (psi): 7 Day - 3750 Tested By: Paul Fuentes (1) Checked In : 10/14/2025 (1,2,3,4,5) Capping Methods U: Unbonded Caps (ASTM C1231) Set #:9 Specimen Size:4" X 8" Specimens In Set:5 Truck / Ticket #:1192 / 1248113 Contractor:J. Scott Technician:Randy Stevenson Cast By:Randy Stevenson Date Cast:10/13/25 Sampled From:Chute Placement Method:Pump Sample Details Batched:09:45 PDT Sampled:10:34 PDT Cast:10:45 PDT Truck Empty:10:50 PDT Placement Time:65 (min) Placement Location:Paving - Sidewalk Location Details:Sidewalk on East side of lower baseball field. Sample Location / Notes:Upper part of sidewalk / landing Batch Log Strength:5000 (psi) Air:3.5 - 6.5 (%) Slump:4 - 6 (in) Specifications Supplier:Miles Plant:202 Sample Condition: Mix Design:1250AFG On-Site Admixtures: None Location Field Measurements Plastic Unit Weight: Air Content:4.6 (ASTM C231) Load Volume:11.00 (yd³) Weather:Sunny Slump (in):6-3/4 (ASTM C143) Air Temperature (F):50 Concrete Temp (F):66 (ASTM C1064) Lab Test Results Testing Lab: Burlington, 777 Chrysler Drive, Burlington, WA, 98233 Attachments Sample #Name Description 5241 20251013_094606.jpg Top Mix Design 5241 20251013_102614.jpg As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Page 1 of 1 Client: Renton School District No. 403 Renton, WA 98057 300 SW 7th St Project: Lindbergh High School Field Improvements 25B121-01 (Bldg Permit: B25002218) Renton, WA 98059 16426 128th Avenue Southeast Compressive Strength of Concrete Test Method: ASTM C 39 Sample: 5241 Sample 5241 Report #: CC-000009-00 Burlington 777 Chrysler Drive Burlington, WA 98233 Phone: (360) 755-1990 Report Date: 10/20/2025 11:52 Page 1 of 2 Description: Top Mix Design As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Page 1 of 0 Client: Renton School District No. 403 Renton, WA 98057 300 SW 7th St Project: Lindbergh High School Field Improvements 25B121-01 (Bldg Permit: B25002218) Renton, WA 98059 16426 128th Avenue Southeast Compressive Strength of Concrete Test Method: ASTM C 39 Sample 5241 Report #: CC-000009-00 Burlington 777 Chrysler Drive Burlington, WA 98233 Phone: (360) 755-1990 Report Date: 10/20/2025 11:52 Page 2 of 2