ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
POWER GENERAL NOTES
1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this
work sketch must be AUTHORIZED by Potelco's Project Manager and NOTED on the Foremans' Copy.
2.All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three
(3) working days in advance.
3.Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work
to get the underground facilities located.
4.All work is to be done in accordance with local municipal and county permit requirements as applicable.
5.Inclement weather conditions may cause delays in construction times and dates.
514302415 186065553
101164646/108148378
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
Sub Order
SITE SPECIFIC NOTES
P01 (318096-166058)
-REPLACE 45' CL3 POLE
-INST 50' CL1 POLE (6010.1000 PD501)
-INST 3Ø SGL ARM (6033.1010 TAN312)
-INST 9' SGL ARM CUTOUT (6011.1000 ARD19C)
-TRANSFER (3) 75kVA 120/240v XFs W/ LB C/O FUSED AT 25T (3412400) EA
-TRANSFER OH SEC. SPLICE & EXTEND IF NECESSARY (_______/___')
-TRANSFER OH SVCs. SPLICE & EXTEND IF NECESSARY (_______/___')
-TOP POLE TO COMMS
N/A
N/A
PSE
No
No
No
Yes
Yes
Yes
No
YesDeveloper
"Flagging Required"
"Outages Required"
"Locates Required"
"Veg Management Required"
"Joint Trench Coord Required"
NoYes
NoYes X
X
X
X
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
SA
P
W
.
O
.
#
18
6
0
6
5
5
5
3
VICINITY MAP
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
OH CIRCUIT MAP: D2305E088
SCALE 6" = 1 MILE DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
M. COBBINAH 253-337-9804 04/03/24
M. COBBINAH 253-337-9804 04/03/24
N/A N/A N/A
A. FARAH N/A 04/03/24
N/A RENTON
ENGR1 COMCAST TK#5654735
REPLACE (1 ) DIST POLE
308 BURNETT AVE N RENTON, WA 98057
POTELCO
N/A N/A
N/A 186065553
AS NOTED 1/1
KING N/A N/A QCSOKE
T23, R05E, S17 N/A N/A
A2305E066 D2305E088 R2305E066NW PCR-14
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
JOB SITE
JOB SITE
NOT TO SCALE
ROW PROFILE: P01
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID #HEIGHT CLASS YEAR TOPPED RMVD
P01 318096-166058 45 3 1975 N/A
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P01 318096-166058 50 1
Installed at site:
Grid Number:
Bank Configuration
Foreman to redline the following information
TRANSFORMER BANK TRANSFER
A Phase Xfrmr MID #
Secondary Voltage:
KVA
B Phase Xfrmr MID #KVA
C Phase Xfrmr MID #KVA
Tested Secondary Voltage:
A Phase Xfrmr Company ID #
B Phase Xfrmr Company ID #
C Phase Xfrmr Company ID #
P01
318096-166058
Wye/Delta
UNITS OF PROPERTY
INSTALL ONLY
CROSSARMS
MATERIAL QTY
DIST. WOOD
DIST. FIBERGLASS
DIST. STEEL
DIST. OTHERS
TRANS. WOOD
TRANS. FIBERGLASS
TRANS. STEEL
TRANS. OTHERS
UNITS OF PROPERTY
INSTALL ONLY
LINE FIXTURES
MATERIAL QTY
DIST. ARRESTERS
DIST. CUTOUTS
DIST. INSULATORS
TRANS. ARRESTERS
TRANS. INSULATORS
SCALE: 1:100
SITE PLAN: P01