Loading...
HomeMy WebLinkAboutMFP25004310.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP25004310 IVR Number: 25004310 Permit Information Permit Name: JB0002269275 OSP DE RN18 Address/Location:08/25/2025Application Date:7221400485Parcel Number: 1500 BEACON WAY S Permit Type:11/06/2025Issue Date:Franchise Permit Work Class:11/06/2026Expiration Date:Major Utility Job Number: JB0002269275 OSP DEFranchise Type:Cable Description: JB0002269275 OSP DE; COMCAST PROPOSES TO PROOF/PULL THRU EXISTING CONDUIT WITH 48CT FIBER 1051LF OVERLASH 48CT FIBER TO EXISTING STRAND (9 POLES) 1339LF PLACE APPROPRIATE STORAGE 50LF REPLACE EQUIPMENT AT AERIAL LOCATION (10) AND UG LOCATION (6) REPLACE EXISTING PEDESTAL WITH NEW DOGHOUSE PEDESTAL (5) TIE IN TO EXISTING SPLICE CASE SP.WAKV.0203 REPLACE EXISTING PIGATIL WITH NEW 12CT PIGTAIL PLACE NEW SPLICE CASE SP0625.WAKV,SP0626.WAKV,SP0627.WAKV,SP0628.WAKV REPLACE EXISTING NODE WAKGRN018 TO NEW 1X2 RFDX NODE WAKVD0C700(1). RESTORATION PER CITY OF RENTON STANDARDS. Contacts Name Address PhoneTypeBilling Ashley Kiehn Mastec Communications 4610 Tacoma Avenue Sumner, WA 98390 ApplicantX Laurie Dietz Comcast - Finance Questions 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Contact Rena Watts Comcast 1575 75th St SW, #200 Everett, WA 98203 B: (425) 977-9120 C: (425) 977-9120 Contact Mastec North America Inc 800 S Douglas Road, 1200 Coral Gables, FL 33134 Contractor Business License Number: 51687Construction Contractor: MASTENA991KJ RENT IN RENTON LLC 2900 NE BLAKELEY ST SEATTLE , WA 98105 Owner Comcast - Billing 1701 John F Kennedy BLVD John F. Kennedy Blvd Philadelphia, PA 19103 B: (425) 918-1140Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES KRISTINE MARTINEZ 08.25.2025 JB0002269275 OSP DE 1500 BEACON WAY S 09.25.2025 10.25.2025 8 AM 3 PM MASTEC NORTH AMERICA DOMINIC MINNITI 253.736.4697 4610 TACOMA AVE SUMNER, WA 98390 COMCAST PROPOSES TO PROOF/PULL THRU EXISTING CONDUIT, OVER- LASH 48 CT FIBER, REPLACE AERIAL AND UNDERGROUND EQUIPMENT DOMINIC MINNITI 253.736.4697 MFP25004310 Monday Friday 8:00am 3:00pm Scott Warlick CED 11/6/2025 COMCAST2A DIGITAL (FDX) - WAKVD0C800 1X2 - WAKVD0C700 1X2 (RN18 3X3)1500 BEACON WY S, RENTON, WA 98057, USAJB0002269275PROPOSED AERIAL AND UG FIBER INSTALLATIONEQUIPMENT REPLACEMENT AT AERIAL AND UG LOCATIONSPEDESTAL REPLACEMENTMFP25004310This permit is for Major construction work in the ROW and will be billed at an additional$158/HR for inspections. After hours and weekend work will be billed at $175/HRRESTORATION PER CITY OF RENTON STANDARDS AARDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)VICINITY MAPCONTACTSPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5-15SITE-PLAN16-19TYPICAL DETAILS19N/AN/AVICINITY MAP2PERMITTINGASHLEY KIEHN4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 999-2271EMAIL: ASKIEHN@SEFNCO.COMCOMCASTSEFNCO OPEDOMINIC MINNITI4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 736-4697EMAIL: DMINNITI@SEFNCO.COMDESCRIPTION OF WORKTOTALPROOF/PULL THRU EXISTING CONDUIT WITH 48CT FIBER1051LFOVERLASH 48CT FIBER TO EXISTING STRAND (9 POLES)1339LFPLACE APPROPRIATE STORAGE50LFREPLACE EQUIPMENT AT AERIAL LOCATION (10) AND UG LOCATION (6)REPLACE EXISTING PEDESTAL WITH NEW DOGHOUSE PEDESTAL (5)TIE IN TO EXISTING SPLICE CASE SP.WAKV.0203REPLACE EXISTING PIGATIL WITH NEW 12CT PIGTAILPLACE NEW SPLICE CASESP0625.WAKV,SP0626.WAKV,SP0627.WAKV,SP0628.WAKVREPLACE EXISTING NODE WAKGRN018 TO NEW 1X2 RFDX NODE WAKVD0C700(1)TOTAL:2440LFJOSHUA ASHLEY11308 SW 68TH PKWYTIGARD, OR 97223PHONE: (503) 939-7931EMAIL: JOSHUA_ASHLEY@COMCAST.COMS1S3S4S51500 BEACON WY S,RENTON, WA 98057CUTOVER BEGIN1500 S 18TH ST,RENTON, WA 98055CUTOVER END1205 GRANT AVE S,RENTON, WA 98055CONSTRUCTION BEGIN630 HIGH AVE S,RENTON, WA 98055CONSTRUCTION ENDS6S7S8S9S11S10S2MFP25004310 RDIGALERTREVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19N/AN/AGENERAL NOTES3 THE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.RENTON1.ALL METHODS AND MATERIALS SPECIFICATION SHALL MEET ALL CITY OF RENTON STANDARDS.2.ALL RENTON STANDARD DETAIL DRAWINGS CAN BE FOUND AT THE FOLLOWING WEBSITE:https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=13637033.ALL ASPHALT REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL -SECTION F 110.0-110.2.4.ALL SIDEWALK REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL- SECTION F 102.0.5.ALL CURB AND GUTTER REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTONSTANDARD DETAIL - SECTION F 103.0.6.UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON DOCUMENT RESEARCH AND FIELD EVALUATION. THEINFORMATION MAY NOT BE ACCURATE OR COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PHYSICALLYLOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES WITHIN THE CONSTRUCTION PATH. ALLINSTALLATIONS MUST COMPLY WITH MINIMUM HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES.MFP25004310 RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19N/AN/ALEGEND 4LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERPOWERPARCEL LINERIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILSDSDWWSSSSGGTTLIPD/LEOPFOCRWRWBUILDING OUTLINEPFLFOG LINESIDEWALKSWSWTRENCHDIRECT BOREPROPOSED AERIAL STRAND PROOF/PULLPROPOSED OVERLASHMINOR ARTERIALCOLLECTOR ARTERIALINTERSTATE FREEWAYACCESS STREETPRINCIPAL ARTERIALBUILDINGR/WWARNING SIGN PLACEMENT (W/ PART #)TRAFFIC BARRELHYDRO-VAC TRENCHKEEPRIGHTREGULATORY SIGN (W/ PART #)LIMITSPEEDR2-125SPEED LIMIT CALLOUTSIGN PLACEMENT / DIRECTIONTRAFFIC CONEFLAGGER STATIONFLAGGER STATIONPATROL CARPOLICEOFFICERUNIFORMED POLICE OFFICERWORK VEHICLEFENCESTREET LIGHT HANDHOLETELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALSTREET LIGHT POLETRAFFIC SIGNAL HANDHOLECATV MANHOLECATV HANDHOLECATV PEDESTALTRAFFIC SIGNAL POLESTORM MANHOLEWATER VALVEWATER METERTELECOM PEDESTALSTORM INLETSTORM DRAIN UNKNOWN D?SISEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?STORM DRAIN VAULT SDSEWER CLEANOUTSEWER MANHOLESCSEWER CATCH BASIN SSSTORM ACCESS POINTBASE LAYERSEXISTING UTILITIESROAD HATCH CLASSIFICATIONROW WORK LINETYPECOMCAST UNDERGROUND SYMBOLSEXISTING UTILITY SYMBOLSTRAFFIC CONTROL SYMBOLSSTORM CATCH BASIN SDTRAFFIC SIGNAL VAULTGAS METERTEST VALVEPEDESTAL UNK UTILITYFIRE HYDRANTGAS VALVEGAS TEST POINTGAS MANHOLEWATER PUMPGGGWATER AIR CONTROL VALVEWATER WELLWATER SAMPLING STATIONPOWER HANDHOLEPOWER MANHOLEPOWER CABINETPOWER VAULTPOWER PEDESTALPPOWER UNKNOWN PPPPPP?SIGN POSTCULVERTTRANSIT STOPBUSSTOPDRIVEWAY (FOC OR EOP)SDSSANCHORSIDEWALK ANCHOR & GUY(P) FIBER & COUNTF48(P) .625 COAX(P) .875 COAXCOMCAST AERIAL SYMBOLSPROPOSEDEXISTINGWRECKOUTPOLE W/O RISERRISERARMVERTICAL GROUNDSLACK SPANOVERHEAD GUYTANGENT ATTACHMENTDEAD-ENDDOUBLE DEAD-END(E) FIBER & COUNTF48(E) .625 COAX(E) .875 COAXSLSLTSTSTSTSCCCTTTTTSTS?PUMPFWELLTREE TRIMLIGHT/MEDIUM/HEAVYLMH//WRECKOUTVAULTSPLICE CASEMANHOLEPEDESTALPPPAMINIBRIDGERTTTAATAPAMPLIFER POTHOLEBORE PIT / EXCAVATIONMMMPROPOSEDEXISTINGWRECKOUTNODEABCDSTORAGE LOOPX'X'LIT INTERSECTIONFASFLASHING ARROWSEQUENTIAL ARROWSEQUENTIAL CHEVRONFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONORFLASHING DIAMOND CAUTIONARROWBOARD PLACEMENT (SEE BELOW)CHANNELIZING DEVICES / MIN DIMENSIONSNOTE(S):1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE, LEGIBILITYDISTANCE, NUMBER OF ELEMENTS AND OTHERSPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OF ARROWHEADEQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVE SOLIDRECTANGULAR APPEARANCES. A TYPE D ARROW BOARDSHALL CONFORM TO THE SHAPE OF THE ARROW.ARROWBOARD TYPE MIN LEGIBILITYDISTANCEMIN SIZE MINIMUM# OFELEMENTSABCD48"×24"60"×30"96"×48"NONE12 MILE1 MILE34 MILE12 MILE121315125FT MIN4FT MIN8-12"45°TYPE 3 BARRICADE3FT MIN45°2FT MIN8-12"TYPE 1 BARRICADE3FT MIN8-12"2FT MIN45°TYPE 2 BARRICADE3-4"6"2"4"28'-36" MAXSPEED < 45MPHNIGHT AND/OR FREEWAYMORE THAN 36"4-6" TYPCONECONESPEED ≥ 45MPHDIRECTION INDICATOR BARRICADE12"8"36" MIN 24" MIN45°UNLIT INTERSECTIONDBTRENCHAVAC-TSPOTTER STATIONALL TRAFFIC CONTROL DEVICES / ANNOTATIONS PER MUTCDAMPLIFIER PICTURETAP PICTUREEquipmentMFP25004310 POLEPOLE POLE REPLACE 2-PAL WITH NEWFDXLE & DC-12 & SPLICEFOCFOCFOCFOCFOCSWSWSWSWSWEOPEOPEOPEOPSWSWSWSWSWSWEOP SWSWSWSWSWSWSWSWSWSWR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/W6276216151500142557515081502151215061415BEACON WY SHIGH AVE S HIGH AVE S S 6TH STR/W R/W R/WR/W R/W R/W R/W R/W R/W BEACON WY SEOPEOPEOPEOPEOPEOPEOP EOP SW SW SW SW HIGH AVE S SWFOCSWFOCSWFOCEOPSWSWSWSWSWSWSWSWSWSWATTALLEYWAY RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 1 5N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION111MFP25004310 R/WR/WR/WR/WR/WR/WR/WR/WR/W PP1205120012001205GRANT AVE SGRANT AVE SGRANT AVE SFOCFOCFOCSWSWSWSWR/WR/WR/WR/WFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCR/WR/WR/WR/WR/WR/WR/WFLFLFLFLFLFLFLFL359'RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 2 6N523TIE INTO EXISTING SPLICE CASESP.WAKV.0203.1SITE PLAN CONSTRUCTION NOTES234REPLACE EXISTING NODE PEDESTALWITH NEW NODE PEDESTAL.PLACE NEW STRAP AND SPLICE CASESP0625.WAKV.PLACE NEW SPLICE CASESP0626.WAKV .UPGRADE EXISTING NODE WAKGRN018TO NEW 1X2 RFDX WAKVD0C700.56PROOF/PULL THRU EXISTINGCONDUIT WITH 48CT FIBER.7469878EXISTING PEDESTAL.REPLACE EQUIPMENT AT UGLOCATION.MATCH TO SITE PLAN - 36GRANT AVE S(PRIVATE RD)9REPLACE EXISTING PIGATIL WITHNEW 12CT PIGTAIL.1MFP25004310 R/WR/W R/WR/WR/W R/W1017GRANT AVE SGRANT AVE S (PRIVATE RD)GRANT AVE S(PRIVATE RD)EOP EOP EOPEOPEOPR/WEOPEOPEOPEOPEOP 239'453'RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 3 7N11SITE PLAN CONSTRUCTION NOTES2PROOF/PULL THRU EXISTINGCONDUIT WITH 48CT FIBER.MATCH TO SITE PLAN - 221EXISTING VALUT.MATCH TO SITE PLAN - 4ALLEYWAY HIGH AVE S MFP25004310 R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WSPOLE A A A A A A A A A A A A A R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W903 14059049071316910912908100510021006GRANT AVE SGRANT AVE SGRANT AVE S S 10TH STHIGH AVE S HIGH AVE S HIGH AVE S SWSWSW 50'SWSWSWSWEOPEOPSWSWSWSWSWEOPEOPEOPEOPEOP EOP EOP SWEOP SW SW SWSWSWSW EOP EOP SW SW SW SW SW EOPEOPEOPEOPEOPEOPR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WEOPR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WAAALLEYWAY ALLEYWAYALLEYWAY POLE 9 POLE 8 149'217'1000910915907DISCONNECT & TERMINATE CABLE & SPLICERDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 4 8N1MATCH TO SITE PLAN - 5234531SITE PLAN CONSTRUCTION NOTES23456PROOF/PULL THRU EXISTINGCONDUIT WITH 48CT FIBER.7RISER UP.EXISTING POLE (9-8).PLACE APPROPRIATE STORAGE (50FT).PLACE NEW SPLICE CASESP0627.WAKV.OVERLASH 48CT FIBER TOEXISTING STRAND.REPLACE EQUIPMENT AT AERIALLOCATION.667MATCH TO SITE PLAN - 37MFP25004310 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W POLESDISCONNECT & TERMINATE CABLE & SPLICEPPLACE NEW POWER INSERTERA A A A A A A A A A A A A A A A A A A R/WR/WR/W801805807806808810802811812S 9TH STS 9TH STHIGH AVE S HIGH AVE S EOP SWSWSWSWSWSWSWSW SW GRANT AVE S EOP SW SWSW SWSW SW SW EOP EOPEOPEOPEOPEOPEOPEOP EOP EOPSWSW SWSWSWSW EOPSW SW SW SW SW SW EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOPSWSWSWSW EOP SW SWSWSW EOP SWSW SWSWSWSWSWSWSWSWR/WR/WSWSWAALLEYWAY ALLEYWAY ALLEYWAY ALLEYWAY S 9TH STS 9TH STS 9TH STPOLE 7 POLE 6 POLE 5153' 154'9011412RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 5 9NMATCH TO SITE PLAN - 62MATCH TO SITE PLAN - 413221111SITE PLAN CONSTRUCTION NOTES2EXISTING POLE (7-5).OVERLASH 48CT FIBER TOEXISTING STRAND.3REPLACE EQUIPMENT AT AERIALLOCATION.MFP25004310 R/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/W R/WR/WR/WR/WR/WPOLE EOPA A A A A A A A A A A A A A A A AAAAAAAAAAAAAAR/WR/WR/WR/W1400140113181321141014226307017097047127157141403712714715716721S 7TH STS 7TH STS 7TH STS 7TH STGRANT AVE SGRANT AVE SGRANT AVE S HIGH AVE S HIGH AVE SEOPSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWEOP SWSWR/W R/W R/W R/W R/WR/WR/W R/W HIGH AVE S FOCSWSW SWSWFOCSW SWSWSWFOC EOPSWSWSW SWSWSWEOPSWSWEOPEOPEOPEOPEOPEOP EOP EOPEOPSW SW SW SW SW SW SW SW SW SWEOP EOP EOP SWEOP SW SW SW SWSWSWSWSW EOP EOP EOPSW SW SW SW SWSWSW SWSW SW EOP SWSW EOPT TALLEYWAY ALLEYWAY ALLEYWAY POLE 4 POLE 3POLE 2POLE 1192'164'158'152'RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 6 10N12MATCH TO SITE PLAN - 51122311SITE PLAN CONSTRUCTION NOTES23EXISTING POLE (4-1).OVERLASH 48CT FIBER TOEXISTING STRAND.456REPLACE EQUIPMENT AT AERIALLOCATION.PLACE NEW 1X2 RFDX NODEWAKVD0C800.PLACE NEW SPLICE CASESP0628.WAKV.END OVERLASH AT NEW SPLICECASE SP0628.WAKV.45666MFP25004310 R/WR/W R/W R/W R/W R/W R/WPEOPFOCFO C FO CEOPEOPEOPEOPEOPFOCFOCFOCFOCFOCFOC EOP EOP EOP EOP FOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSW S W S WSWSW S W S W SW SWSWSWSWSWSWSWSWSWSWSWSW R/W R/W R/WR/WR/WR/WR/WR/WR/WR/W R/ W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/ W R/ WR/WR/WR/WR/WR/WR/W1513151817077111719S 7TH STJONES AVE S JONES AVE S BEACON WY SBEACON WY SSE 8TH STR/W R/W R/W R/W R/W R/W R/W FOCFOCFOCFOCSWFOC FOC FOC SWSWSWSWSE 7 T H C TSE 8TH STAEOP SW SW SW SWFOCSWSWRDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 7 11N12REPLACE EQUIPMENT AT UGLOCATION.12SITE PLAN CONSTRUCTION NOTESREPLACE EXISTING PEDESTAL WITHNEW DOGHOUSE PEDESTAL.MFP25004310 PPFOC FOCFOCFOCFOCFOCFOCFOCFOCSW SWSWSWSWSWSWSWSWSWSWFOCSWFOCFOCSWSWR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W18051811181718091815182118141820182618271800SE 8TH PLSE 8TH STLINCOIN AVE SE LINCOIN AVE SE FOCSWFOCSWSW FOC SWFOCSWFOCSWFOCFOCSWSW FOC SWSWFOCFOCSWSWFOCSWFOCSWSWFOCSWFOCSWSE 8TH STAAFOCFOCFOCFOCSWSWSWSWSWRDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 8 12N21REPLACE EQUIPMENT AT UGLOCATION.12SITE PLAN CONSTRUCTION NOTESREPLACE EXISTING PEDESTAL WITHNEW DOGHOUSE PEDESTAL.12MFP25004310 R/WR/WR/WR/WR/WR/W R/W R/W R/W POLE FOCEOPEOP SW R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/WR/WR/WR/WS 9TH STJONES AVE S JONES AVE S FOC FOC FOC FOC SWSWEOP15208119011511A RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 9 13N1REPLACE EQUIPMENT AT AERIALLOCATION.1SITE PLAN CONSTRUCTION NOTESMFP25004310 PFLFLFLFLFLFLFLFLFOCFOCFOC FO C FOC FOC FOC FOC FOC FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FLFOCFOCSWSWSWSWSWR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W GRANT AVE SGRANT AVE S FOC FOC FOC FOC FOCSW SW SW SW SW SW SW A1411RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 10 14N12REPLACE EQUIPMENT AT UGLOCATION.12SITE PLAN CONSTRUCTION NOTESREPLACE EXISTING PEDESTAL WITHNEW DOGHOUSE PEDESTAL.MFP25004310 R/W R/W R/W P FL FL FL FL FL FL FL FL FL FL FL FL FLFL FL FL FL FL FL FL FL FL FL FL FL FO C FO C FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCSWSWSW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW R/W R/W R/W R/W R/W R/W R/W R/W R/W GRANT AVE SFOC FOC FOC SW SW SW SW 150016261705ARDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 11 15N21REPLACE EQUIPMENT AT UGLOCATION.12SITE PLAN CONSTRUCTION NOTESREPLACE EXISTING PEDESTAL WITHNEW DOGHOUSE PEDESTAL.MFP25004310 19REVISIONSDATEDESCRIPTIONINITIALRDIGALERTREVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)NTS16TYPICAL DETAILS-1STARLINE SERIES: MB1001 GHz MINIBRIDGERFEATURES:·SIMPLIFY PLANT UPGRADES WITH MODULAR RFDESIGN AND 1.2 GHZ CAPABLE HOUSING·IMPROVE AMPLIFIER REACH WITH OPTIONAL GANTECHNOLOGY AND INCREASED STATION TILT·MAINTAIN CURRENT AMPLIFIER SPACING WITH HIGHOUTPUT GAAS TECHNOLOGY·EXPAND RETURN PATH BANDWIDTH WITH PLUG‐INDIPLEX FILTER SUPPORT TO 85 MHZ·MINIMIZE RF DRIFT OVER TEMPERATURE WITHOPTIONAL ANALOG OR QAM ADUHOUSING DIMENSIONS (L×W×D): 15.4" x 9.6" x 5.5"292 mm x 244 mm x140 mmWEIGHT:15 lb6.8kgFFT*-* Q SERIES·FFT2-*Q: 2 PORT TAPS·FFT4-*Q: 4 PORT TAPS·FFT8-*Q: 8 PORT TAPS·FFT*-PBA-V: 2 PORT TAPSFEATURES:·SUPPORT DOCSIS 3.1 EXPANDED BANDWIDTH UP TO1218 MHz.·IMPROVE NETWORK PERFORMANCE WITH SIGNALCONDITIONING PLUG-INS.·HIGH QUALITY RF CONNECTION WITH AUTO-SEIZEF-CONNECTORS.·MAINTAIN EXISTING INSTALLED BASE WITHCOMPATIBILITY BACK TO "F" SERIES FFT HOUSINGS.·STANDARD FACEPLATE ONLY OPTIONS FORCOST-EFFECTIVE UPGRADES TO EXISTING FFTDEPLOYMENTS.·HIGH LEVEL OF NETWORK RESILIENCE WITH 6 kVSURGE RESISTANCE ON FEEDERLINE AND F-PORTS.·BLANK TAP OPTION FFT*-PBA-V FOR FUTUREEXPANSION·MAINTAIN RF AND AC CONNECTIONS WITH FACEPLATEREMOVED WITH INTEGRATED BYPASS CAPABILITY.HOUSING DIMENSIONS (L×W×D): 4.0" x 2.9" x 5.6"10.2cm x 7.4cm x 14.2cmWEIGHT:1 lb0.45kgTAPSTARLINE SERIES: MB100AUX1 GHz AMPLIFIERFEATURES:·SIMPLIFY PLANT UPGRADES WITH MODULAR RF DESIGNAND 1.2 GHZ CAPABLE HOUSING·IMPROVE AMPLIFIER REACH WITH OPTIONAL GANTECHNOLOGY AND INCREASED STATION TILT·MAINTAIN CURRENT AMPLIFIER SPACING WITH HIGHOUTPUT GAAS TECHNOLOGY·EXPAND RETURN PATH BANDWIDTH WITH PLUG‐INDIPLEX FILTER SUPPORT TO 85 MHZ·MINIMIZE RF DRIFT OVER TEMPERATURE WITH OPTIONALANALOG OR QAM ADUHOUSING DIMENSIONS (L×W×D): 15.4" x 9.6" x 5.5"292 mm x 244 mm x140 mmWEIGHT:15 lb6.8kgAMPLIFIERHARDWARE REPLACEMENT DIMENSIONSMINIBRIDGERMFP25004310 19REVISIONSDATEDESCRIPTIONINITIALRDIGALERTREVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)NTS17TYPICAL DETAILS-2 AERIAL TYPICALSMFP25004310 19REVISIONSDATEDESCRIPTIONINITIALRDIGALERTREVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)NTS18TYPICAL DETAILS-3 TYPICAL FOR DOGHOUSE INSTALLATIONMFP25004310 19REVISIONSDATEDESCRIPTIONINITIALRDIGALERTREVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)NTS19TYPICAL DETAILS-4 TYPICAL FOR NODE PEDESTAL INSTALLATIONCOMCASTPIN W/ LARGE WASHER1 12"TOP VIEW1 / 4"1 / 4"DETAIL-D1 / 4" X 1 12" VENTS SLOTS ONUNDERSIDE EACH HOOD (7X)44"26"2 - 1 / 4"8 - 1 / 2"PIN W/ LARGE WASHERD42"44 - 7 / 8"COVER (FRONT VIEW)COVER ( END VIEW )1 - 1 / 2"VENTS ON UNDERSIDEALL AROUND RIB( 224 SQUARE INCHES )23 - 7 / 8"27 - 1 / 4"7"3"25 - 7 / 8"8 - 1 / 2"5 / 8"1 / 4"1 / 4"1 / 4"1 / 4"1"1 - 1 / 2"1 - 1 / 2"1 - 1 / 4"2 - 1 / 4"DETAIL - CBASE (TOP VIEW)45 - 3 / 8"44 - 3 / 8"27 - 1 / 8"28 - 1 / 8"25 - 1 / 2"24 - 1 / 4"26 - 1 / 2"23 - 1 / 4"41 - 1 / 8"41 - 7 / 8"43 - 1 / 8"44 - 1 / 8"BASE ( END VIEW )26 - 1 / 2"24 - 1 / 4"28 - 1 / 8"41"44 - 1 / 8"24"10 - 1 / 4"10 - 1 / 4"41 - 7 / 8"45 - 3 / 4"BASE ( FRONT VIEW )LARGEWASHERP6001260XXXB= BOLT TYPE PATTERN 1801H= BOLT TYPE SEMS BOLT (7 / 16" HEX)K= BOLT TYPE PATTERN 169 (P KEY)C= LAM LOCK (SELF LOCK)A= LIGHT GREEN COLORC= DARK GREEN COLORDRAWING NO.TOP COLORLIGHT GREENFOREST GREENBEIGEP6001260ACH-COMP6001260CCH-COMP6001260DCH-COMP6-1260XX-COMCASTFILE NAMEMFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 MFP25004310 ___________________________________________________________________________________ MasTec Network Solutions 4610 Tacoma Ave Sumner, WA 98390 ____________________________________________________________________________________________________________ MasTec Washington Locations Spokane ~ Puget Sound October 24, 2025 To whom it may concern: City of Renton 1055 South Grady Way Renton, WA 98057 RE: Aerial Variance Request for JB0002269275 OSP DE RN18 To whom it may concern, Mastec North America has been contracted to design and engineer this project on behalf of Comcast Cablevision. Comcast is applying for a variance request in order to upgrade their existing facilities. Comcast proposes to overlash 48 ct fiber to existing strand. Comcast is requesting that the City of Renton approve this variance request based on the fact that the requirements for undergrounding this proposed over-lash will not cause substantial adverse impacts to other person or entities in the immediate area and will cause undue hardship. 1. Installation of undergrounding facilities will increase the total cost of construction roughly 15-25 times the amount of an aerial over-lash on the existing Comcast strand. 2. Potential damage to underground facilities will be increased. 3. Over-lash will not cause substantial adverse impact to other persons or entities in the immediate area. Over-lashing the cable will be accomplished in a few days, and the residents will not notice any impact. Comcast will clean up the over-lashed spans as necessary and identify and remove any existing dead cables along this route. 4. The variance is necessary to prevent and undue hardship due to the increased construction costs if forced to install the proposed extension underground. 5. The granting of the variance will not be materially detrimental to the public welfare because Comcast does agree to underground the cable system, but they are waiving the obligation into the future when all other utilities are underground to prevent an undue hardship against Comcast currently. ___________________________________________________________________________________ MasTec Network Solutions 4610 Tacoma Ave Sumner, WA 98390 ____________________________________________________________________________________________________________ MasTec Washington Locations Spokane ~ Puget Sound Upon the granting of the Variance, Comcast will coordinate construction and traffic control as per your requirements. Comcast and their contractors want to cooperate at the highest level and agree to adhere to all provisions and requirements set forth by the City of Renton to ensure safe installation and maintenance of the proposed facilities. If you have any further questions regarding this project please contact Dominic Minitti at 253-736-4697. Thank you for your consideration in this matter. Ashley Kiehn Ashley Kiehn Director of Operations Support MasTec North America Cell (253)797-8118 | Ashley.Kiehn@mastec.com Attachments: 1. Application for ROW permit 2. 11” x 17” Site plan 3. 11” x 17” Design plan 4. Traffic Control Plan November 6, 2025 Ashley Kiehn Mastec North America 4610 Tacoma Avenue, Sumner WA 98390 Via Email: Ashley.Kiehn@mastec.com SUBJECT: Request for Undergrounding Exemption (JB#2259275, MFP25004310, 1500 Beacon Way S) Dear Ms. Kiehn: The City of Renton has reviewed your request to grant Comcast an exemption from Renton Municipal Code (RMC) 4-6-090(C) which states that all new electrical or communication facilities shall be required to be installed underground, pursuant to the standards of the section of RMC. Comcast proposes to have Mastec North America overlash new fiber for a total of approximately 1339 lineal feet to existing Puget Sound Energy (PSE) poles along Grant Ave S and S 7th St within the City. See the enclosed Site Plan showing the proposed overlashing limits. ANALYSIS: The City has considered the request for an exemption from RMC 4-6-090. Ordinance 5720 grants Comcast, the right to install fiber optic cable and related appurtenances under, along, over, below, through and across the streets, avenues and alleys of City of Renton within the right-of-way of Renton. Section 3.4 of the franchise ordinance states that if all of the distribution lines all the wireline service providers, such as telecommunications service providers, as defined in RCW 35.99.010, a utility service provider or a Cable Operator (collectively “Service Providers”) in any portion of the Franchise Area are underground, Grantee shall place its Cable System’s distribution cables underground within that area; provided that such underground locations are actually capable of accommodating Grantee’s cable and other equipment without technical degradation of the Cable Systems’ signal quality. The proposal would utilize existing poles with other attached franchisee communication facilities and overlash to the existing Comcast aerial path. As minimum vertical height clearance of 15’-6” would need to be provided for, any existing obsolete cable will need to be removed; staff recommends these as conditions of approval. Therefore, the City is granting an exemption with conditions, per the Comcast franchise agreement which allows new overhead facilities to be placed overhead provided there are other similar providers overhead as well. Comcast is required to obtain all necessary private utility easements for work on private property. DECISION: The requested exemption from underground utility installation requirements RMC4-6-090 (C) as requested by the applicant is approved with conditions subject to the conditions below as the request complies with the Comcast Franchise Agreement. Comcast Job JB#2259275 Page 2 of 2 November 6, 2025 Conditions of Approval: 1. Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15’-6”. 2. Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 3. A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 4. The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. This decision to approve the exemption with conditions is subject to a fourteen (14) day appeal period from the date of this letter per RMC 4-8-110. Any appeals of the administrative decision must be filed with the City Clerk, along with the required appeal fee, by 5:00 pm, November 20, 2025. Appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov or delivered to City Hall 1st floor Lobby Hub Monday through Friday.  The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date if your appeal is submitted electronically. The appeal submitted in person may be paid on the first floor in our Finance Department. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov.   Sincerely, Justin Johnson, PE Interim Development Engineering Director cc: Nathan Janders, Development Engineering Manager Scott Warlick, Engineering Specialist III Holly Powers, Engineering Specialist III Franchise Permits Enclosures: Site Plan Justin Johnson COMCAST2A DIGITAL (FDX) - WAKVD0C800 1X2 - WAKVD0C700 1X2 (RN18 3X3)1500 BEACON WY S, RENTON, WA 98057, USAJB0002269275PROPOSED AERIAL AND UG FIBER INSTALLATIONEQUIPMENT REPLACEMENT AT AERIAL AND UG LOCATIONSPEDESTAL REPLACEMENTMFP25004310This permit is for Major construction work in the ROW and will be billed at an additional$158/HR for inspections. After hours and weekend work will be billed at $175/HRRESTORATION PER CITY OF RENTON STANDARDS AARDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)VICINITY MAPCONTACTSPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5-15SITE-PLAN16-19TYPICAL DETAILS19N/AN/AVICINITY MAP2PERMITTINGASHLEY KIEHN4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 999-2271EMAIL: ASKIEHN@SEFNCO.COMCOMCASTSEFNCO OPEDOMINIC MINNITI4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 736-4697EMAIL: DMINNITI@SEFNCO.COMDESCRIPTION OF WORKTOTALPROOF/PULL THRU EXISTING CONDUIT WITH 48CT FIBER1051LFOVERLASH 48CT FIBER TO EXISTING STRAND (9 POLES)1339LFPLACE APPROPRIATE STORAGE50LFREPLACE EQUIPMENT AT AERIAL LOCATION (10) AND UG LOCATION (6)REPLACE EXISTING PEDESTAL WITH NEW DOGHOUSE PEDESTAL (5)TIE IN TO EXISTING SPLICE CASE SP.WAKV.0203REPLACE EXISTING PIGATIL WITH NEW 12CT PIGTAILPLACE NEW SPLICE CASESP0625.WAKV,SP0626.WAKV,SP0627.WAKV,SP0628.WAKVREPLACE EXISTING NODE WAKGRN018 TO NEW 1X2 RFDX NODE WAKVD0C700(1)TOTAL:2440LFJOSHUA ASHLEY11308 SW 68TH PKWYTIGARD, OR 97223PHONE: (503) 939-7931EMAIL: JOSHUA_ASHLEY@COMCAST.COMS1S3S4S51500 BEACON WY S,RENTON, WA 98057CUTOVER BEGIN1500 S 18TH ST,RENTON, WA 98055CUTOVER END1205 GRANT AVE S,RENTON, WA 98055CONSTRUCTION BEGIN630 HIGH AVE S,RENTON, WA 98055CONSTRUCTION ENDS6S7S8S9S11S10S2MFP25004310 RDIGALERTREVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19N/AN/AGENERAL NOTES3 THE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.RENTON1.ALL METHODS AND MATERIALS SPECIFICATION SHALL MEET ALL CITY OF RENTON STANDARDS.2.ALL RENTON STANDARD DETAIL DRAWINGS CAN BE FOUND AT THE FOLLOWING WEBSITE:https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=13637033.ALL ASPHALT REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL -SECTION F 110.0-110.2.4.ALL SIDEWALK REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL- SECTION F 102.0.5.ALL CURB AND GUTTER REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTONSTANDARD DETAIL - SECTION F 103.0.6.UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON DOCUMENT RESEARCH AND FIELD EVALUATION. THEINFORMATION MAY NOT BE ACCURATE OR COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PHYSICALLYLOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES WITHIN THE CONSTRUCTION PATH. ALLINSTALLATIONS MUST COMPLY WITH MINIMUM HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES.MFP25004310 RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19N/AN/ALEGEND 4LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERPOWERPARCEL LINERIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILSDSDWWSSSSGGTTLIPD/LEOPFOCRWRWBUILDING OUTLINEPFLFOG LINESIDEWALKSWSWTRENCHDIRECT BOREPROPOSED AERIAL STRAND PROOF/PULLPROPOSED OVERLASHMINOR ARTERIALCOLLECTOR ARTERIALINTERSTATE FREEWAYACCESS STREETPRINCIPAL ARTERIALBUILDINGR/WWARNING SIGN PLACEMENT (W/ PART #)TRAFFIC BARRELHYDRO-VAC TRENCHKEEPRIGHTREGULATORY SIGN (W/ PART #)LIMITSPEEDR2-125SPEED LIMIT CALLOUTSIGN PLACEMENT / DIRECTIONTRAFFIC CONEFLAGGER STATIONFLAGGER STATIONPATROL CARPOLICEOFFICERUNIFORMED POLICE OFFICERWORK VEHICLEFENCESTREET LIGHT HANDHOLETELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALSTREET LIGHT POLETRAFFIC SIGNAL HANDHOLECATV MANHOLECATV HANDHOLECATV PEDESTALTRAFFIC SIGNAL POLESTORM MANHOLEWATER VALVEWATER METERTELECOM PEDESTALSTORM INLETSTORM DRAIN UNKNOWN D?SISEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?STORM DRAIN VAULT SDSEWER CLEANOUTSEWER MANHOLESCSEWER CATCH BASIN SSSTORM ACCESS POINTBASE LAYERSEXISTING UTILITIESROAD HATCH CLASSIFICATIONROW WORK LINETYPECOMCAST UNDERGROUND SYMBOLSEXISTING UTILITY SYMBOLSTRAFFIC CONTROL SYMBOLSSTORM CATCH BASIN SDTRAFFIC SIGNAL VAULTGAS METERTEST VALVEPEDESTAL UNK UTILITYFIRE HYDRANTGAS VALVEGAS TEST POINTGAS MANHOLEWATER PUMPGGGWATER AIR CONTROL VALVEWATER WELLWATER SAMPLING STATIONPOWER HANDHOLEPOWER MANHOLEPOWER CABINETPOWER VAULTPOWER PEDESTALPPOWER UNKNOWN PPPPPP?SIGN POSTCULVERTTRANSIT STOPBUSSTOPDRIVEWAY (FOC OR EOP)SDSSANCHORSIDEWALK ANCHOR & GUY(P) FIBER & COUNTF48(P) .625 COAX(P) .875 COAXCOMCAST AERIAL SYMBOLSPROPOSEDEXISTINGWRECKOUTPOLE W/O RISERRISERARMVERTICAL GROUNDSLACK SPANOVERHEAD GUYTANGENT ATTACHMENTDEAD-ENDDOUBLE DEAD-END(E) FIBER & COUNTF48(E) .625 COAX(E) .875 COAXSLSLTSTSTSTSCCCTTTTTSTS?PUMPFWELLTREE TRIMLIGHT/MEDIUM/HEAVYLMH//WRECKOUTVAULTSPLICE CASEMANHOLEPEDESTALPPPAMINIBRIDGERTTTAATAPAMPLIFER POTHOLEBORE PIT / EXCAVATIONMMMPROPOSEDEXISTINGWRECKOUTNODEABCDSTORAGE LOOPX'X'LIT INTERSECTIONFASFLASHING ARROWSEQUENTIAL ARROWSEQUENTIAL CHEVRONFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONORFLASHING DIAMOND CAUTIONARROWBOARD PLACEMENT (SEE BELOW)CHANNELIZING DEVICES / MIN DIMENSIONSNOTE(S):1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE, LEGIBILITYDISTANCE, NUMBER OF ELEMENTS AND OTHERSPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OF ARROWHEADEQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVE SOLIDRECTANGULAR APPEARANCES. A TYPE D ARROW BOARDSHALL CONFORM TO THE SHAPE OF THE ARROW.ARROWBOARD TYPE MIN LEGIBILITYDISTANCEMIN SIZE MINIMUM# OFELEMENTSABCD48"×24"60"×30"96"×48"NONE12 MILE1 MILE34 MILE12 MILE121315125FT MIN4FT MIN8-12"45°TYPE 3 BARRICADE3FT MIN45°2FT MIN8-12"TYPE 1 BARRICADE3FT MIN8-12"2FT MIN45°TYPE 2 BARRICADE3-4"6"2"4"28'-36" MAXSPEED < 45MPHNIGHT AND/OR FREEWAYMORE THAN 36"4-6" TYPCONECONESPEED ≥ 45MPHDIRECTION INDICATOR BARRICADE12"8"36" MIN 24" MIN45°UNLIT INTERSECTIONDBTRENCHAVAC-TSPOTTER STATIONALL TRAFFIC CONTROL DEVICES / ANNOTATIONS PER MUTCDAMPLIFIER PICTURETAP PICTUREEquipmentMFP25004310 POLEPOLE POLE REPLACE 2-PAL WITH NEWFDXLE & DC-12 & SPLICEFOCFOCFOCFOCFOCSWSWSWSWSWEOPEOPEOPEOPSWSWSWSWSWSWEOP SWSWSWSWSWSWSWSWSWSWR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/W6276216151500142557515081502151215061415BEACON WY SHIGH AVE S HIGH AVE S S 6TH STR/W R/W R/WR/W R/W R/W R/W R/W R/W BEACON WY SEOPEOPEOPEOPEOPEOPEOP EOP SW SW SW SW HIGH AVE S SWFOCSWFOCSWFOCEOPSWSWSWSWSWSWSWSWSWSWATTALLEYWAY RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 1 5N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION111MFP25004310 R/WR/WR/WR/WR/WR/WR/WR/WR/W PP1205120012001205GRANT AVE SGRANT AVE SGRANT AVE SFOCFOCFOCSWSWSWSWR/WR/WR/WR/WFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCR/WR/WR/WR/WR/WR/WR/WFLFLFLFLFLFLFLFL359'RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 2 6N523TIE INTO EXISTING SPLICE CASESP.WAKV.0203.1SITE PLAN CONSTRUCTION NOTES234REPLACE EXISTING NODE PEDESTALWITH NEW NODE PEDESTAL.PLACE NEW STRAP AND SPLICE CASESP0625.WAKV.PLACE NEW SPLICE CASESP0626.WAKV .UPGRADE EXISTING NODE WAKGRN018TO NEW 1X2 RFDX WAKVD0C700.56PROOF/PULL THRU EXISTINGCONDUIT WITH 48CT FIBER.7469878EXISTING PEDESTAL.REPLACE EQUIPMENT AT UGLOCATION.MATCH TO SITE PLAN - 36GRANT AVE S(PRIVATE RD)9REPLACE EXISTING PIGATIL WITHNEW 12CT PIGTAIL.1MFP25004310 R/WR/W R/WR/WR/W R/W1017GRANT AVE SGRANT AVE S (PRIVATE RD)GRANT AVE S(PRIVATE RD)EOP EOP EOPEOPEOPR/WEOPEOPEOPEOPEOP 239'453'RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 3 7N11SITE PLAN CONSTRUCTION NOTES2PROOF/PULL THRU EXISTINGCONDUIT WITH 48CT FIBER.MATCH TO SITE PLAN - 221EXISTING VALUT.MATCH TO SITE PLAN - 4ALLEYWAY HIGH AVE S MFP25004310 R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WSPOLE A A A A A A A A A A A A A R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W903 14059049071316910912908100510021006GRANT AVE SGRANT AVE SGRANT AVE S S 10TH STHIGH AVE S HIGH AVE S HIGH AVE S SWSWSW 50'SWSWSWSWEOPEOPSWSWSWSWSWEOPEOPEOPEOPEOP EOP EOP SWEOP SW SW SWSWSWSW EOP EOP SW SW SW SW SW EOPEOPEOPEOPEOPEOPR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WEOPR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WAAALLEYWAY ALLEYWAYALLEYWAY POLE 9 POLE 8 149'217'1000910915907DISCONNECT & TERMINATE CABLE & SPLICERDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 4 8N1MATCH TO SITE PLAN - 5234531SITE PLAN CONSTRUCTION NOTES23456PROOF/PULL THRU EXISTINGCONDUIT WITH 48CT FIBER.7RISER UP.EXISTING POLE (9-8).PLACE APPROPRIATE STORAGE (50FT).PLACE NEW SPLICE CASESP0627.WAKV.OVERLASH 48CT FIBER TOEXISTING STRAND.REPLACE EQUIPMENT AT AERIALLOCATION.667MATCH TO SITE PLAN - 37MFP25004310 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W POLESDISCONNECT & TERMINATE CABLE & SPLICEPPLACE NEW POWER INSERTERA A A A A A A A A A A A A A A A A A A R/WR/WR/W801805807806808810802811812S 9TH STS 9TH STHIGH AVE S HIGH AVE S EOP SWSWSWSWSWSWSWSW SW GRANT AVE S EOP SW SWSW SWSW SW SW EOP EOPEOPEOPEOPEOPEOPEOP EOP EOPSWSW SWSWSWSW EOPSW SW SW SW SW SW EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOPSWSWSWSW EOP SW SWSWSW EOP SWSW SWSWSWSWSWSWSWSWR/WR/WSWSWAALLEYWAY ALLEYWAY ALLEYWAY ALLEYWAY S 9TH STS 9TH STS 9TH STPOLE 7 POLE 6 POLE 5153' 154'9011412RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 5 9NMATCH TO SITE PLAN - 62MATCH TO SITE PLAN - 413221111SITE PLAN CONSTRUCTION NOTES2EXISTING POLE (7-5).OVERLASH 48CT FIBER TOEXISTING STRAND.3REPLACE EQUIPMENT AT AERIALLOCATION.MFP25004310 R/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/W R/WR/WR/WR/WR/WPOLE EOPA A A A A A A A A A A A A A A A AAAAAAAAAAAAAAR/WR/WR/WR/W1400140113181321141014226307017097047127157141403712714715716721S 7TH STS 7TH STS 7TH STS 7TH STGRANT AVE SGRANT AVE SGRANT AVE S HIGH AVE S HIGH AVE SEOPSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWEOP SWSWR/W R/W R/W R/W R/WR/WR/W R/W HIGH AVE S FOCSWSW SWSWFOCSW SWSWSWFOC EOPSWSWSW SWSWSWEOPSWSWEOPEOPEOPEOPEOPEOP EOP EOPEOPSW SW SW SW SW SW SW SW SW SWEOP EOP EOP SWEOP SW SW SW SWSWSWSWSW EOP EOP EOPSW SW SW SW SWSWSW SWSW SW EOP SWSW EOPT TALLEYWAY ALLEYWAY ALLEYWAY POLE 4 POLE 3POLE 2POLE 1192'164'158'152'RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 6 10N12MATCH TO SITE PLAN - 51122311SITE PLAN CONSTRUCTION NOTES23EXISTING POLE (4-1).OVERLASH 48CT FIBER TOEXISTING STRAND.456REPLACE EQUIPMENT AT AERIALLOCATION.PLACE NEW 1X2 RFDX NODEWAKVD0C800.PLACE NEW SPLICE CASESP0628.WAKV.END OVERLASH AT NEW SPLICECASE SP0628.WAKV.45666MFP25004310 R/WR/W R/W R/W R/W R/W R/WPEOPFOCFO C FO CEOPEOPEOPEOPEOPFOCFOCFOCFOCFOCFOC EOP EOP EOP EOP FOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSW S W S WSWSW S W S W SW SWSWSWSWSWSWSWSWSWSWSWSW R/W R/W R/WR/WR/WR/WR/WR/WR/WR/W R/ W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/ W R/ WR/WR/WR/WR/WR/WR/W1513151817077111719S 7TH STJONES AVE S JONES AVE S BEACON WY SBEACON WY SSE 8TH STR/W R/W R/W R/W R/W R/W R/W FOCFOCFOCFOCSWFOC FOC FOC SWSWSWSWSE 7 T H C TSE 8TH STAEOP SW SW SW SWFOCSWSWRDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 7 11N12REPLACE EQUIPMENT AT UGLOCATION.12SITE PLAN CONSTRUCTION NOTESREPLACE EXISTING PEDESTAL WITHNEW DOGHOUSE PEDESTAL.MFP25004310 PPFOC FOCFOCFOCFOCFOCFOCFOCFOCSW SWSWSWSWSWSWSWSWSWSWFOCSWFOCFOCSWSWR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W18051811181718091815182118141820182618271800SE 8TH PLSE 8TH STLINCOIN AVE SE LINCOIN AVE SE FOCSWFOCSWSW FOC SWFOCSWFOCSWFOCFOCSWSW FOC SWSWFOCFOCSWSWFOCSWFOCSWSWFOCSWFOCSWSE 8TH STAAFOCFOCFOCFOCSWSWSWSWSWRDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 8 12N21REPLACE EQUIPMENT AT UGLOCATION.12SITE PLAN CONSTRUCTION NOTESREPLACE EXISTING PEDESTAL WITHNEW DOGHOUSE PEDESTAL.12MFP25004310 R/WR/WR/WR/WR/WR/W R/W R/W R/W POLE FOCEOPEOP SW R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/WR/WR/WR/WS 9TH STJONES AVE S JONES AVE S FOC FOC FOC FOC SWSWEOP15208119011511A RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 9 13N1REPLACE EQUIPMENT AT AERIALLOCATION.1SITE PLAN CONSTRUCTION NOTESMFP25004310 PFLFLFLFLFLFLFLFLFOCFOCFOC FO C FOC FOC FOC FOC FOC FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FLFOCFOCSWSWSWSWSWR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W GRANT AVE SGRANT AVE S FOC FOC FOC FOC FOCSW SW SW SW SW SW SW A1411RDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 10 14N12REPLACE EQUIPMENT AT UGLOCATION.12SITE PLAN CONSTRUCTION NOTESREPLACE EXISTING PEDESTAL WITHNEW DOGHOUSE PEDESTAL.MFP25004310 R/W R/W R/W P FL FL FL FL FL FL FL FL FL FL FL FL FLFL FL FL FL FL FL FL FL FL FL FL FL FO C FO C FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOCSWSWSW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW R/W R/W R/W R/W R/W R/W R/W R/W R/W GRANT AVE SFOC FOC FOC SW SW SW SW 150016261705ARDIGALERTREVISIONSDATEDESCRIPTIONINITIALCOMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)19SITE PLAN - 11 15N21REPLACE EQUIPMENT AT UGLOCATION.12SITE PLAN CONSTRUCTION NOTESREPLACE EXISTING PEDESTAL WITHNEW DOGHOUSE PEDESTAL.MFP25004310 19REVISIONSDATEDESCRIPTIONINITIALRDIGALERTREVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)NTS16TYPICAL DETAILS-1STARLINE SERIES: MB1001 GHz MINIBRIDGERFEATURES:·SIMPLIFY PLANT UPGRADES WITH MODULAR RFDESIGN AND 1.2 GHZ CAPABLE HOUSING·IMPROVE AMPLIFIER REACH WITH OPTIONAL GANTECHNOLOGY AND INCREASED STATION TILT·MAINTAIN CURRENT AMPLIFIER SPACING WITH HIGHOUTPUT GAAS TECHNOLOGY·EXPAND RETURN PATH BANDWIDTH WITH PLUG‐INDIPLEX FILTER SUPPORT TO 85 MHZ·MINIMIZE RF DRIFT OVER TEMPERATURE WITHOPTIONAL ANALOG OR QAM ADUHOUSING DIMENSIONS (L×W×D): 15.4" x 9.6" x 5.5"292 mm x 244 mm x140 mmWEIGHT:15 lb6.8kgFFT*-* Q SERIES·FFT2-*Q: 2 PORT TAPS·FFT4-*Q: 4 PORT TAPS·FFT8-*Q: 8 PORT TAPS·FFT*-PBA-V: 2 PORT TAPSFEATURES:·SUPPORT DOCSIS 3.1 EXPANDED BANDWIDTH UP TO1218 MHz.·IMPROVE NETWORK PERFORMANCE WITH SIGNALCONDITIONING PLUG-INS.·HIGH QUALITY RF CONNECTION WITH AUTO-SEIZEF-CONNECTORS.·MAINTAIN EXISTING INSTALLED BASE WITHCOMPATIBILITY BACK TO "F" SERIES FFT HOUSINGS.·STANDARD FACEPLATE ONLY OPTIONS FORCOST-EFFECTIVE UPGRADES TO EXISTING FFTDEPLOYMENTS.·HIGH LEVEL OF NETWORK RESILIENCE WITH 6 kVSURGE RESISTANCE ON FEEDERLINE AND F-PORTS.·BLANK TAP OPTION FFT*-PBA-V FOR FUTUREEXPANSION·MAINTAIN RF AND AC CONNECTIONS WITH FACEPLATEREMOVED WITH INTEGRATED BYPASS CAPABILITY.HOUSING DIMENSIONS (L×W×D): 4.0" x 2.9" x 5.6"10.2cm x 7.4cm x 14.2cmWEIGHT:1 lb0.45kgTAPSTARLINE SERIES: MB100AUX1 GHz AMPLIFIERFEATURES:·SIMPLIFY PLANT UPGRADES WITH MODULAR RF DESIGNAND 1.2 GHZ CAPABLE HOUSING·IMPROVE AMPLIFIER REACH WITH OPTIONAL GANTECHNOLOGY AND INCREASED STATION TILT·MAINTAIN CURRENT AMPLIFIER SPACING WITH HIGHOUTPUT GAAS TECHNOLOGY·EXPAND RETURN PATH BANDWIDTH WITH PLUG‐INDIPLEX FILTER SUPPORT TO 85 MHZ·MINIMIZE RF DRIFT OVER TEMPERATURE WITH OPTIONALANALOG OR QAM ADUHOUSING DIMENSIONS (L×W×D): 15.4" x 9.6" x 5.5"292 mm x 244 mm x140 mmWEIGHT:15 lb6.8kgAMPLIFIERHARDWARE REPLACEMENT DIMENSIONSMINIBRIDGERMFP25004310 19REVISIONSDATEDESCRIPTIONINITIALRDIGALERTREVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)NTS17TYPICAL DETAILS-2 AERIAL TYPICALSMFP25004310 19REVISIONSDATEDESCRIPTIONINITIALRDIGALERTREVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)NTS18TYPICAL DETAILS-3 TYPICAL FOR DOGHOUSE INSTALLATIONMFP25004310 19REVISIONSDATEDESCRIPTIONINITIALRDIGALERTREVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:BBS08/22/20252A DIGITAL (FDX) - WAKVD0C800 1X2 - 1500 BEACON WY S RENTON, WA 98057, USA JB0002269275 WAKVD0C700 1X2 (RN18 3X3)NTS19TYPICAL DETAILS-4 TYPICAL FOR NODE PEDESTAL INSTALLATIONCOMCASTPIN W/ LARGE WASHER1 12"TOP VIEW1 / 4"1 / 4"DETAIL-D1 / 4" X 1 12" VENTS SLOTS ONUNDERSIDE EACH HOOD (7X)44"26"2 - 1 / 4"8 - 1 / 2"PIN W/ LARGE WASHERD42"44 - 7 / 8"COVER (FRONT VIEW)COVER ( END VIEW )1 - 1 / 2"VENTS ON UNDERSIDEALL AROUND RIB( 224 SQUARE INCHES )23 - 7 / 8"27 - 1 / 4"7"3"25 - 7 / 8"8 - 1 / 2"5 / 8"1 / 4"1 / 4"1 / 4"1 / 4"1"1 - 1 / 2"1 - 1 / 2"1 - 1 / 4"2 - 1 / 4"DETAIL - CBASE (TOP VIEW)45 - 3 / 8"44 - 3 / 8"27 - 1 / 8"28 - 1 / 8"25 - 1 / 2"24 - 1 / 4"26 - 1 / 2"23 - 1 / 4"41 - 1 / 8"41 - 7 / 8"43 - 1 / 8"44 - 1 / 8"BASE ( END VIEW )26 - 1 / 2"24 - 1 / 4"28 - 1 / 8"41"44 - 1 / 8"24"10 - 1 / 4"10 - 1 / 4"41 - 7 / 8"45 - 3 / 4"BASE ( FRONT VIEW )LARGEWASHERP6001260XXXB= BOLT TYPE PATTERN 1801H= BOLT TYPE SEMS BOLT (7 / 16" HEX)K= BOLT TYPE PATTERN 169 (P KEY)C= LAM LOCK (SELF LOCK)A= LIGHT GREEN COLORC= DARK GREEN COLORDRAWING NO.TOP COLORLIGHT GREENFOREST GREENBEIGEP6001260ACH-COMP6001260CCH-COMP6001260DCH-COMP6-1260XX-COMCASTFILE NAMEMFP25004310 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Conditions for Permit MFP25004310 Engineering 1 A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 2 Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15'-6". 3 The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. 4 Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. Page 1 of 1