Loading...
HomeMy WebLinkAboutD_Jones_Short_Plat_South_FINALDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Project Location Map D_Admin Decision_Jones South SP_2511_FINAL A. ADMINISTRATIVE REPORT & DECISION Decision: APPROVED APPROVED SUBJECT TO CONDITIONS DENIED Report Date: November 7, 2025 Project File Number: PR25-000010 Project Name: Jones Renton Short Plat - South Land Use File Number: LUA25-000111, SHPL-A, MOD Project Manager: Alex Morganroth, Principal Planner Owner/Applicant: Park Ave 5 LLC, 4044 148th Ave NE, Redmond, WA 98052 Contact: Kevin Rech / 3412 210th Pl NE, Sammamish, WA 98074 / kevin@cadehillhomes.com Project Location: 3215 Park Ave N, Renton, WA 98056 (APN 3342103250) Project Summary: The applicant is requesting Preliminary Short Plat approval and a Street Modification to subdivide a vacant property into two (2) lots. The project site (APN 3342103250) is located at 3215 Park Ave N. The site totals approximately 17,722 square feet (0.41 acres), is zoned Residential-6 (R-6), and has a Comprehensive Plan Land Use Designation of Residential Medium Density (RMD). The applicant previously received preliminary approval for a five-lot Short Plat on the adjoining parcel to the north (LUA20-000237). As part of that approval, a 2,473-square-foot tract was proposed along the south side of the new public road, with the intent that this tract would later be incorporated into the subject property. Because both parcels are under the same ownership, the applicant proposes to complete a lot line adjustment prior to recording the earlier Short Plat in order to consolidate the area identified as Tract B into the new lots proposed under this application. The proposed lots would be approximately 8,933 square feet (Lot 1) and 8,656 square feet (Lot 2) in size after incorporating the land included in the lot line adjustment. One (1) new single- family residence would be constructed on each of the proposed lots. Access would be provided via individual driveways from the new public road currently under construction as part of the adjacent Short Plat (LUA20-000237). The applicant has proposed removal of the one (1) existing tree on the site. Critical areas mapped on the site include a moderate landslide hazard area and Wellhead Protection Area Zone 2. Supporting technical documents submitted with the application include a Preliminary Technical Information Report (TIR), Tree Assessment, and Geotechnical Evaluation. Site Area: 17,722 square feet (0.41 acres) Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 2 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL B. EXHIBITS: Exhibit 1: Administrative Decision Exhibit 2: Site Plan Exhibit 3: Boundary & Topographic Survey Exhibit 4: Preliminary Landscape Plans Exhibit 5: Grading, Storm Drainage, and Utility Plans Exhibit 6: Construction Mitigation Description Exhibit 7: Preliminary Tree Retention & Replacement Plan Exhibit 8: Tree Retention and Credit Worksheet Exhibit 9: Tree Assessment, dated September 26, 2023 Exhibit 10: Geotechnical Evaluation, prepared by Earth Solutions NW, LLC (ESNW), dated November 27, 2023 Exhibit 11: Preliminary Technical Information Report (TIR), prepared by CORE Design, Inc., dated October 16, 2024 Exhibit 12: Street Modification Request, dated August 24, 2024 Exhibit 13: Renton School District Letter Exhibit 14: Duwamish Tribe Comment, dated May 2, 2025 Exhibit 15: City Response to Duwamish Tribe Comment, dated May 6, 2025 Exhibit 16: Advisory Notes C. GENERAL INFORMATION: 1. Owner(s) of Record: Park Ave 5 LLC, 4044 148th Ave NE, Redmond, WA 98052 2. Zoning Classification: Residential-6 (R-6) 3. Comprehensive Plan Land Use Designation: Residential Medium Density (RMD) 4. Existing Site Use: Vacant 5. Critical Areas: Well 5A Wellhead Protection Area Zone 2 and Moderate Landslide Hazard Area 6. Neighborhood Characteristics: a. North: Future single-family residences. Residential-6 (R-6) zone and Residential Medium Density (RMD) land use designation. b. East: Jones Renton Short Plat and Fire Station #15. Residential-6 (R-6) zone and Residential Medium Density (RMD) land use designation. Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 3 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL c. South: Restaurant. Commercial Neighborhood (CN) zone and Residential High Density (RHD) land use designation. d. West: Single-family residences. Residential-8 (R-8) zone and Residential Medium Density (RMD) land use designation. 7. Site Area: 17,722 square feet (0.41 acres) D. HISTORICAL/BACKGROUND: Action Land Use File No. Ordinance No. Date Comprehensive Plan N/A 6153 12/09/2024 Zoning N/A 6154 12/09/2024 Kennydale Annexation A-69-002 2531 12/31/1969 E. PUBLIC SERVICES: 1. Existing Utilities a. Water: Water service will be provided by the City of Renton. There is an existing 12-inch (12”) water main located in Park Ave N that can deliver a maximum flowrate of 3,500 GPM. The City will be installing an eight-inch (8”) water main in Park Ave N as part of the Kennydale Reservoir Offsite Improvements project. The new main will be located near the centerline of the street and will run parallel to the existing 12-inch (12”) main. b. Sewer: Sanitary sewer service will be provided by the City of Renton. There is an existing eight- inch (8”) PVC gravity wastewater main located in Park Ave N. c. Surface/Storm Water: There are no formal storm drainage improvements located within the Park Ave N right-of-way (ROW) along the site’s frontage. 2. Streets: The proposed project fronts Park Ave N, which is classified as a Collector Arterial with an existing right-of-way (ROW) width of approximately 50 feet (50’). 3. Fire Protection: Renton Regional Fire Authority (RRFA) F. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE: 1. Chapter 2 Zoning Districts – Uses and Standards a. Section 4-2-020: Purpose and Intent of Zoning Districts b. Section 4-2-060: Zoning Use Table – Uses Allowed in Zoning Designations c. Section 4-2-110: Residential Development Standards d. Section 4-2-115: Residential Design and Open Space Standards 2. Chapter 3 Environmental Regulations and Overlay Districts a. Section 4-3-050: Critical Areas Regulations 3. Chapter 4 City-Wide Property Development Standards 4. Chapter 6 Street and Utility Standards Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 4 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL a. Section 4-6-060: Street Standards 5. Chapter 7 Subdivision Regulations a. Section 4-7-070: Detailed Procedures for Short Subdivisions 6. Chapter 9 Permits – Specific a. Section 4-9-250: Variances, Waivers, Modifications, and Alternates 7. Chapter 11 Definitions G. APPLICABLE SECTIONS OF THE COMPREHENSIVE PLAN: 1. Land Use Element H. FINDINGS OF FACT (FOF): 1. The Planning Division of the City of Renton accepted the above master application for review on April 24, 2025 and determined the application complete on May 1, 2025. 2. The project site is located at 3215 Park Ave N, Renton, WA 98056 (APN 3342103250). 3. The project site is currently vacant. 4. Access to both proposed lots would be provided via a new public access road off of Park Ave N, which is being constructed as part of LUA20-000237 under Civil Permit C24002370 (Exhibit 2). 5. The property is located within the Residential Medium Density (RMD) Comprehensive Plan land use designation. 6. The site is located within the Residential-6 (R-6) zoning classification. 7. There is one (1) landmark tree located on-site which the applicant is proposing to remove (Exhibit 7). 8. The site contains a moderate landslide hazard area and is within the Well 5A Wellhead Protection Area Zone 2. 9. The project site slopes downward from northeast to west-southwest, with a total vertical relief of about 10 feet (10’), from approximately 214 feet (214’) to approximately 204 feet (204’) (Exhibit 3). The applicant did not indicate the amount of cut or fill proposed. 10. The applicant is proposing to begin construction upon issuance of the land use decision (Exhibit 6). 11. Staff received one (1) public comment from the Duwamish Tribe requesting archaeological monitoring, the use of native vegetation, and the preservation of mature trees (Exhibit 14). Staff responded to the comment (Exhibit 15) and notified the applicant of the comment. No other public or agency comments were received during the 14-day public comment period. 12. Representatives from various city departments have reviewed the application materials to identify and address issues raised by the proposed development. These comments are contained in the official file, and the essence of the comments has been incorporated into the appropriate sections of this report and the Departmental Recommendation at the end of this report. 13. Comprehensive Plan Compliance: The site is designated Residential Medium Density (RMD) on the City’s Comprehensive Plan Map. The purpose of the RMD designation is to support high-quality, compact, urban development with access to urban services, transit, and infrastructure, whether through new development or through infill development. The proposal is compliant with the following Comprehensive Plan Goals and Policies if all conditions of approval are met: Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 5 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL Compliance Comprehensive Plan Analysis  Policy LU-3: Encourage infill development with a variety of housing types to meet growth targets and provide a greater variety of housing options.  Goal LU-I: Accommodate residential growth, by: • Supporting infill development on vacant and underutilized land in established low- moderate-density residential neighborhoods; and • Allowing development of new detached housing on large tracts of land outside the City Center.  Goal LU-BB: Ensure new development supports a high quality of life with design that is functional and attractive.  Goal LU-FF: Strengthen the visual identity of Renton and its Community Planning Areas and neighborhoods through quality design and development.  Policy LU-48: Consider scale and context for infill project design to preserve privacy and quality of life for residents. 14. Zoning Development Standard Compliance: The site is classified as Residential-6 (R-6) on the City’s Zoning Map. Development in the R-6 zone is established for single-family housing and allows middle housing where there is land suitable for infill and larger lot development at a moderate density. All development standards analyses for this proposal are based on the anticipated lot configuration and lot sizes following the lot line adjustment with the adjacent parcel to the north (LUA20-000237), as proposed by the applicant. A recommended condition of approval under FOF 17: Compliance with Subdivision Regulations would require completion of the lot line adjustment prior to recording of the Short Plat. The proposal is compliant with the following development standards, as outlined in RMC 4-2-110A, provided all conditions of approval are met: Compliance R-6 Zone Develop Standards and Analysis  Density: The allowed density in the R-6 zone is a minimum of 3.0 up to a maximum of 6.0 dwelling units per net acre. Net density is calculated after the deduction of sensitive areas, areas intended for public right-of-way, and private access easements. All fractions which result from net density calculations shall be truncated at two (2) numbers past the decimal (e.g., 4.5678 becomes 4.56). Calculations for minimum or maximum density which result in a fraction that is one-half (0.50) or greater shall be rounded up to the nearest whole number. Those density calculations resulting in a fraction that is less than one-half (0.50) shall be rounded down to the nearest whole number. Staff Comment: The project site has a gross area of 17,722 square feet (0.41 acres). The proposed lot line adjustment with the adjoining parcel to the north (LUA20-000237) would incorporate a planned tract (identified as Tract B on the approved Short Plat plan, but not yet recorded) of approximately 2,473 square feet into the subject site, resulting in a final combined gross area of 20,195 square feet (0.46 acres). For density purposes, no deductions are required for critical areas, as none are present on the site that affect net density. Approximately 530 square feet of right-of-way (ROW) dedication is proposed, resulting in a net site area (including land added after the proposed lot line adjustment) of 19,665 square feet (0.45 acres). The proposal for two (2) lots on the 0.45-net-acre site would result in a net density of 4.43 dwelling units per net Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 6 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL acre, which falls within the allowable density range of 3.0 to 6.0 dwelling units per net acre in the R-6 zone. A recommended condition of approval under FOF 17: Compliance with Subdivision Regulations would require completion of the lot line adjustment prior to recording of the Short Plat. Compliant if condition of approval is met Lot Dimensions: The minimum lot size permitted in the R-6 zone is 7,000 square feet. A minimum lot width of 60 feet is required (70 feet for corner lots) and a minimum lot depth of 90 feet is required. The following table identifies the proposed approximate dimensions for Lots 1-2 after the proposed lot line adjustment with the adjacent parcel is recorded: Proposed Lot Parcel Size (sq. ft.) Lot Width (ft.) Lot Depth (ft.) Lot 1 (corner lot) 8,933 90 100 Lot 2 (interior lot) 8,656 90 103 Staff Comment: As proposed, both lots would comply with the minimum width, depth, and size requirements of the R-6 zone. Lot 1 is classified as a corner lot, with frontage along Park Ave N to the west and along a new street (identified as Road A) to the north of the project site. The new street is being constructed as part of the adjacent Jones Short Plat (LUA20-000237). Accordingly, the future single-family home on Lot 1 would establish its primary front yard along Park Ave N and a secondary front yard along future Road A. Lot 2 is classified as an interior lot with frontage along future Road A. To satisfy the minimum lot width and depth standards, the applicant has oriented the lot so that the width is measured north to south and the depth is measured east to west. Under this configuration, a future home on Lot 2 would not naturally orient toward a public street. To ensure appropriate street orientation, staff recommends as a condition of approval, that the primary pedestrian entry of the future dwelling on Lot 1 face Park Ave N and the primary pedestrian entry of the future dwelling on Lot 2 face future Road A. The orientation requirement shall be noted on the face of the final Short Plat. With this condition, both lots would maintain their primary front yard orientation toward a public street, consistent with the intent of the R-6 standards. Compliant if condition of approval is met Setbacks: The required setbacks in the R-6 zone are as follows: front yard is 25 feet, side yard is combined 15 feet with not less than 5 feet on either side, secondary front yard (applies to corner lots) is 25 feet, and the rear yard is 25 feet. Staff Comment: As shown on the preliminary Short Plat (Exhibit 2), the proposed lots provide sufficient area to comply with the required setbacks and bulk standards of the R-6 zone. Lot 1, classified as a corner lot, has street frontage on Park Ave N and secondary frontage along the future Road A. Setbacks for Lot 1 would be applied in accordance with its corner lot designation. Lot 2 is classified as an interior lot. While the applicant has oriented the lot to measure width north to south and depth east to west, staff finds it appropriate that setback application be based on the lot’s relationship to surrounding development and public streets. For Lot 2, the north property line shall be considered the front yard setback, the south property line the rear yard setback, Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 7 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL and the east and west property lines the side yard setbacks. To ensure consistent application of setbacks and provide clarity for future permitting, staff recommends as a condition of approval that the setback designations applied to Lot 2 shall be the following: the north property line shall be considered the front yard setback, the south property line the rear yard setback, and the east and west property lines the side yard setbacks. The requirement shall be clearly noted on the face of the final Short Plat. Compliance with the setback requirements for the individual homes will be verified at the time of Building Permit review. Compliance not yet demonstrated Building Standards: The R-6 zone has a maximum building coverage of 40% and a maximum impervious surface coverage of 55%. In the R-6 zone, a maximum building height of 2 stories with a wall plate height of 24 feet is permitted. Roofs with a pitch equal to or greater than 4:12 may project an additional six (6) vertical feet from the maximum wall plate height. If the height of wall plates on a building are less than the states maximum the roof may project higher to account for the difference, yet the combined height of both features shall not exceed the combined maximums. Common rooftop features, such as chimneys, may project an additional four (4) vertical feet from the roof surface. Non-exempt vertical projections (e.g., roofs pitched less than 4:12, decks, railings, etc.) may extend up to six (6) vertical feet above the maximum wall plate height if the projection is stepped back one-and-a-half (1.5) horizontal feet from each minimum building setback line for each one (1) vertical foot above the maximum wall plate height. Wall plates supporting a primary roof surface that has only one (1) sloping plane (e.g., shed roof) may exceed the stated maximum if the average of wall plate heights is equal or less than the maximum wall plate height allowed. Staff Comment: Building height, building coverage, and impervious surface coverage for the new single-family residences would be verified at the time of Building Permit review. Compliant if condition of approval is met Landscaping: The City’s landscape regulations (RMC 4-4-070) require a 10-foot landscape strip along all public street frontages. Additional minimum planting strip widths between the curb and sidewalk are established according to the street development standards of RMC 4-6-060. Minimum planting strip widths between the curb and sidewalk are established according to the street development standards of RMC 4-6-060. Street trees and, at a minimum, groundcover shall be planted within planting strips pursuant to the following standards, provided there shall be a minimum of one street tree planted per lot. a. Trees shall be selected from the City’s Approved Street Tree List based on the width of the planting strip and the presence or lack of overhead power lines; provided, the Administrator and City arborist shall each retain the right to reject any proposed cultivar regardless of whether or not the cultivar is on the City’s Approved Street Tree List. b. Street trees shall have a minimum caliper of two inches (2"), and be planted pursuant to the standards promulgated by the City, which may require root barriers, structured soils, or other measures to help prevent tree roots from damaging infrastructure. Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 8 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL c. Street trees shall be planted in the center of the planting strip between the curb and the sidewalk at the following intervals; provided, that, where right-of- way is constrained, irregular intervals and slight increases or decreases may be permitted or required. Additionally, trees shall be planted in locations that meet required spacing distances from facilities located in the right-of-way including, but not limited to, underground utilities, streetlights, utility poles, traffic signs, fire hydrants, and driveways; such spacing standards are identified in the City’s Approved Tree List. Generally, the following spacing is required: i. Small-sized maturing trees: thirty feet (30') on center; ii. Medium-sized maturing trees: forty feet (40') on center; and iii. Large-sized maturing trees: fifty feet (50') on center. Any additional undeveloped right-of-way areas shall be landscaped unless otherwise determined by the Administrator. Where there is insufficient right-of-way space or no public frontage, street trees are required in the front yard subject to approval of the Administrator. A minimum of two trees are to be located in the front yard prior to final inspection for the new Single-Family Residence. Staff Comment: The applicant submitted Preliminary Landscape Plans (Exhibit 4) prepared by CORE Design, Inc. The landscape plan includes a planting strip between the curb and sidewalk along Park Ave N that would have a width of eight feet (8’). Two (2) Eastern redbud trees, an approved street tree species, are proposed in the planter strip along Park Ave N and adjacent to proposed Lot 1. Four (4) silver linden street trees will be installed in the planter strip along future Road A as part of the civil construction improvements approved under the Civil Permit for the adjacent Jones Short Plat (C24002370). The proposed ground cover within both street planting strips will consist of showy fleabane. In addition, the preliminary landscape plans included a ten-foot (10’) wide on- site landscape strip along Park Ave N and future Road A. The ten-foot (10’) landscape strip would be planted with trees and 483 unidentified shrubs and groundcover as shown on the Landscape Plan (Exhibit 5). Four (4) London plane trees are proposed within the ten-foot (10’) on-site landscape strip. In order to ensure compliance with the landscape standards prior to construction, staff recommends, as a condition of approval, that the applicant submit a detailed landscape plan at the time of Civil Construction Permit review. The detailed landscape plan shall identify individual plant species and quantities in all landscaped areas of the site, as well as the street planter strip, and shall be submitted to the Current Planning Project Manager for review and approval prior to the issuance of a Civil Construction Permit. Compliant if condition of approval is met Tree Retention: The City’s adopted Tree Retention and Land Clearing Regulations (4-4-130) require the retention of 30 percent of trees in a residential development. Tree credit requirements shall apply at a minimum rate of 30 credits per net acre. The tree density may consist of existing trees, replacement trees, trees required pursuant to RMC 4-4-070F.1, Street Frontage Landscaping Required, or a combination. Significant trees shall be retained in the following priority order: Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees on slopes greater than twenty percent (20%); significant trees Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 9 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL adjacent to critical areas and their associated buffers; and significant trees over sixty feet (60') in height or greater than eighteen inches (18") caliper. Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other significant native evergreen or deciduous trees; and other significant non- native trees. Priority Three: Alders and cottonwoods shall be retained when all other trees have been evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods are used as part of an approved enhancement project within a critical area or its buffer. Staff Comment: A Tree Retention Plan (Exhibit 7) and Tree Assessment (Exhibit 9) were included with the project application materials. According to the documents, one (1) tree was inventoried for the proposed project. The tree proposed for removal is a 32.1-inch DBH big leaf maple, classified as a landmark tree. Based on the 30 percent (30%) tree retention requirement, a total of 0.3 trees must be retained, rounded down to zero (0). The applicant is proposing to retain no trees (Exhibits 7 and 8). Therefore, the applicant’s proposal complies with the required retention rate in RMC 4-4-130. The project site has a net site area of 19,665 square feet (0.45 acres) after completion of the lot line adjustment and roadway dedication. Based on a net developable area of 0.45 acres, a total of 14 (rounded up from 13.5) tree credits would be required on the project site (0.45 acres x 30 tree credits/ac = 13.5 tree credits). The six (6) new large species trees, including two (2) Western red cedar and four (4) London plane trees, that the applicant is proposing to plant would result in a total of 12 tree credits on the project site, which would not comply with the minimum tree credit requirements for the site. Therefore, staff recommends as a condition of approval, the applicant shall submit a detailed landscape plan at the time of Civil Construction Permit that documents compliance with the tree credit requirements in RMC 4-4-130H.1.b. The detailed landscape plan shall be reviewed and approved by the Current Planning Project Manager prior to permit issuance.  Parking: Parking regulations require that a minimum of two parking spaces be provided for each detached dwelling. Driveway cuts are required to be a minimum of 5 feet from property lines and new driveways may be a maximum of 16 feet in width at the property line. Maximum driveway slopes shall not exceed fifteen percent (15%); provided, that driveways exceeding eight percent (8%) shall provide slotted drains at the lower end with positive drainage discharge to restrict runoff from entering the garage/residence or crossing any public sidewalk. Staff Comment: The proposed lots include adequate area to provide the required two (2) parking spaces per dwelling unit. See additional access and parking discussion below under FOF 17: Compliance with Subdivision Regulations. Compliance not yet demonstrated Fences and Retaining Walls: In any residential district, the maximum height of any fence, hedge or retaining wall shall be seventy two inches (72"). Except in the front yard and side yard along a street setback where the fence shall not exceed forty eight inches (48") in height. Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 10 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL There shall be a minimum three-foot (3') landscaped setback at the base of retaining walls abutting public rights-of-way. Staff Comment: Block walls are proposed within future Lot 1 and Lot 2. None of the wall heights exceed four feet (4’) in height. Compliance with the wall height and setback requirements would be verified at the time of formal Civil and Building Permit reviews. 15. Design Standards: Residential Design and Open Space Standards (RMC 4-2-115) are applicable in the R-6 zone. The Standards implement policies established in the Land Use Element of the Comprehensive Plan in order to enhance quality of life by encouraging new residential development to produce beautiful neighborhoods of well-designed homes, and to mitigate adverse impacts of density for the neighborhood and the surrounding community. Compliance with Site Design Standards must be demonstrated prior to approval of the subdivision. Compliance with Residential Design Standards would be verified prior to issuance of the building permit for the new single-family homes. The proposal is consistent with the following design standards, unless noted otherwise: Compliance Design Standards and Analysis N/A Lot Configuration: One of the following is required of preliminary plat applications: 1. One (1) out of every four (4) abutting lots on a street frontage shall provide a lot width variation of at least ten feet (10') minimum, or 2. Minimum of four (4) lot sizes (minimum of four hundred (400) gross square feet size difference) for street-fronting lots, or 3. A front yard setback variation of at least five feet (5’) minimum for at least every four (4) abutting street fronting lots. Staff Comment: Not applicable, as the proposal is a Short Plat.  Lots shall be configured to achieve both of the following: 1. The location of stormwater infiltration LID facilities is optimized, consistent with the Surface Water Design Manual. Building and property line setbacks are specified in the Surface Water Design Manual for infiltration facilities. 2. Soils with good infiltration potential for stormwater management are preserved to the maximum extent practicable as defined by the Surface Water Design Manual. Staff Comment: See drainage discussion below under FOF 19, Availability and Impact on Public Services. Compliance not yet demonstrated Garages: All of the following are required: 1. If an attached garage is wider than twenty-six feet (26'), at least one (1) garage door shall be recessed a minimum of four feet (4') from the other garage door; 2. For corner lots, attached garages shall not be located on the building corner that fronts two streets (public street, private street, or shared driveway); and 3. Garage doors shall contain a minimum of thirty percent (30%) glazing and/or architectural detailing (e.g., trim and hardware). Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 11 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL Additionally, one of the following is required: 1. The front porch projects in front of the garage a minimum of five feet (5’), and is a minimum of twelve feet (12’) wide, or 2. The roof extends at least five feet (5') (not including eaves) beyond the front of the garage for at least the width of the garage plus the porch/stoop area, or 3. The garage is alley accessed, or 4. The garage entry does not face a public and/or private street or an access easement, or 5. The garage width represents no greater than fifty percent (50%) of the width of the front facade at ground level, or 6. The garage is detached. Staff Comment: Compliance for this standard would be verified at the time of Building Permit review. Compliance not yet demonstrated Primary Entry: All of the following are required: 1. All ground-related dwelling units shall provide a covered porch entry with a minimum depth of five feet (5'), unless the dwelling units are accessed entirely from an internal common corridor, in which case the shared entry shall feature a covered porch with a minimum depth of five feet (5'); 2. Entries shall be a minimum height of twelve inches (12") above grade; 3. Entries shall take access from and face a street, park, common green, pocket park, pedestrian easement, or open space; and 4. Ground-related units that front two (2) streets shall engage both streets utilizing design features that wrap the corner of the building, such as a wraparound porch or pergola. Exception: in cases where accessibility (ADA) is a priority, an accessible route may be taken from a front driveway. Staff Comment: Compliance for this standard would be verified at the time of Building Permit review. However, it should be noted that the future home built on Lot 1 is classified as a corner lot and therefore “front” facade design elements would be expected on both the west and north facades. Compliance not yet demonstrated Facade Modulation: Building facades that front a shared driveway, public street, park, common green, pocket park, pedestrian easement, or open space shall provide at least one (1) articulation or change in plane of at least two feet (2') in depth, with a width no less than ten feet (10’). Staff Comment: Compliance for this standard would be verified at the time of Building Permit review. Compliance not yet demonstrated Windows and Doors: Windows and doors shall constitute twenty-five percent (25%) of all facades facing street frontage or public spaces. Windows and doors shall constitute a minimum of twenty percent (20%) of the secondary front facade when the home is located on a corner lot; and Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 12 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL Sliding glass doors are not permitted along a frontage elevation or an elevation facing a pedestrian easement. Staff Comment: Compliance for this standard would be verified at the time of Building Permit review. It should be noted that both the west and north facades of the new home on proposed Lot 1 would be required to incorporate windows and doors at a rate of 25 percent (25%) along Park Ave N and 20 percent (20%) along the future road to the north, or obtain an approved modification issued at the discretion of staff. Compliance not yet demonstrated Scale, Bulk, and Character: A variety of elevations and models that demonstrate a variety of floor plans, home sizes, and character shall be used. All of the following are required: 1. A variety of elevations and models that demonstrate a variety of home sizes, and character. 2. Abutting, adjacent, and diagonal dwelling shall have differing architectural elevations. 3. No more than two (2) of the same model and elevation shall be built on the same block frontage, or within the same cluster (when applicable). Staff Comment: Compliance for this standard would be verified at the time of Building Permit review. Compliance not yet demonstrated Roofs: Both of the follow are required: 1. A variety of roofing colors shall be used within a development and all roof material shall be fire retardant; 2. Single-family residential subdivisions and cottage housing developments shall use a variety of roof forms, appropriate to the style of the home. Staff Comment: Compliance for this standard would be verified at the time of Building Permit review. Compliance not yet demonstrated Eaves: Both of the following are required: 1. Eaves projecting from the roof of the entire building at least twelve inches (12") with horizontal fascia or fascia gutter at least five inches (5") deep on the face of all eaves, and 2. Rakes on gable ends must extend a minimum of two inches (2") from the surface of exterior siding materials. Staff Comment: Compliance for this standard would be verified at the time of Building Permit review. Compliance not yet demonstrated Architectural Detailing: Architectural detailing shall be provided in a manner appropriate to the architectural character of the home. All of the following is required: 1. Three and one-half inches (3 1/2") minimum trim surrounding all windows and detailing all doors; Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 13 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL 2. If only one (1) siding material is used on any building facade that is two stories or greater in height, a horizontal band that measures at least eight inches (8") is required between the first and second story; 3. At least one (1) of the following architectural details shall be provided on each home: dormers, shutters, knee braces, flower boxes, or columns; 4. Where siding is used, metal corner clips or corner boards shall be used and shall be at minimum two and one-half inches (2 1/2") in width and painted; and 5. If columns are used, they shall be round, fluted, or strongly related to the home’s architectural style. Posts (6" x 6") may be allowed if chamfered and/or banded. Exposed posts (6" x 6" or smaller) are prohibited. Staff Comment: Compliance for this standard would be verified at the time of Building Permit review. Compliance not yet demonstrated Color Palettes: For subdivisions and short plats, a diverse palette of colors shall be used on homes throughout the community to reduce monotony of color or tone. Additionally, all of the following are required: 1. Color palettes for all new buildings, coded to the building elevations, shall be submitted for approval; 2. For detached dwellings (excluding ADUs), abutting, adjacent, and diagonal homes shall be of differing color; 3. To differentiate same models and elevations within a development, different colors shall be used; 4. Multiple colors on buildings shall be provided; and 5. Gutters and downspouts shall be integrated into the color scheme of the building and be painted to match the trim color, or an integral color of the home. Staff Comment: Compliance for this standard would be verified at the time of Building Permit review. Compliance not yet demonstrated Building Materials: A diversity of building materials, appropriate to the architectural character of the home, shall be used to add visual interest and reduce monotony. All of the following are required: 1. Buildings shall incorporate a minimum of two (2) differing siding materials (horizontal siding and shingles, siding and masonry or masonry-like material, etc.) on street-facing facades. One (1) alternative siding material must comprise a minimum of thirty percent (30%) of the street-facing facade; 2. Material transitions or changes shall not occur at an exterior corner, but shall wrap the corner no less than twenty-four inches (24"). The material change shall occur at an internal corner or a logical transition, such as aligning with a window edge or chimney; 3. Acceptable exterior wall materials include: wood, cement fiberboard, stucco, stone, and standard sized brick ((3 1/2" x 7 1/2") or (3 5/8" x 7 5/8")); and Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 14 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL 4. Simulated stone, wood, or brick may be used only for detailing and not for the primary form of the building. Staff Comment: Compliance for this standard would be verified at the time of Building Permit review. 16. Critical Areas: Project sites which contain critical areas are required to comply with the Critical Areas Regulations (RMC 4-3-050). The proposal is consistent with the Critical Areas Regulations, if all conditions of approval are complied with: Compliance Critical Areas Analysis  Geologically Hazardous Areas: Based upon the results of a geotechnical report and/or independent review, conditions of approval for developments may include buffers and/or setbacks from buffers. A standard 15-foot building setback is required for all structures from Protected Slope areas. A 50-foot buffer and 15-foot building setback are required from Very High Landslide Hazard Areas. Staff Comment: A moderate landslide hazard is located on the site. Therefore, the applicant submitted a Geotechnical Evaluation, prepared by Earth Solutions NW, LLC (ESNW), dated November 27, 2023 (Exhibit 10), with the project application materials. The report documents subsurface exploration consisting of three (3) test pits excavated on-site. Subsurface conditions generally consisted of topsoil underlain by silt with sand and sandy silt consistent with Vashon recessional outwash deposits. Seasonal groundwater seepage was not observed at the time of exploration. The geotechnical report concludes that the site is suitable for development with conventional spread and continuous footing foundations bearing on competent native soils or new structural fill, with an allowable bearing capacity of 2,500 psf. Anticipated settlement is less than one inch (1”), with differential settlement of approximately one-half inch (1/2”). Infiltration is considered generally feasible, with a recommended preliminary long-term design rate of one inch (1”) per hour, provided that adequate separation from seasonal high groundwater and impermeable layers can be achieved. Liquefaction susceptibility is considered low due to soil density and absence of a shallow groundwater table. The report provides recommendations for structural fill, temporary and permanent slope design, slab-on-grade construction, retaining walls, seismic design parameters, and drainage measures including footing drains. Staff recommends that the applicant comply with all recommendations contained in the geotechnical report. Final review of infiltration feasibility, slope stability, and foundation subgrades would occur at the time of Civil Construction Permit review.  Wellhead Protection Areas: Staff Comment: The COR mapping system has identified the site as being located in the Wellhead Protection Area Zone 2 (Well 5A). The site’s proposed residential use is not indicative of a type of use that would potentially harm the City’s groundwater. No groundwater is proposed to be withdrawn, and no waste material would be discharged into the ground. If more than 100 cubic yards of fill are Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 15 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL imported, a fill material source statement is required that is certified by a professional engineer or geologist licensed by the State of Washington identifying each source location of the fill. 17. Compliance with Subdivision Regulations: RMC 4-7 Provides review criteria for the subdivisions. The proposal is consistent with the following subdivision regulations if all conditions of approval are complied with: Compliance Subdivision Regulations and Analysis Compliant if conditions of approval are met Access: Each lot must have access to a public street or road. Access may be by a shared driveway per the requirements of RMC 4-6-060 Street Standards. Alley access is the preferred street pattern for all new residential development. All new residential development in an area that has existing alley(s) shall utilize alley access. New residential development in areas without existing alleys shall utilize alley access for interior lots. If the developer or property owner demonstrates that alley access in not practical, the use of alley(s) may not be required. The City will consider the following factors in determining whether the use of alley(s) in not practical: a. Size: The new development is a short plat. b. Topography: The topography of the site proposed for development is not conducive for an alley configuration. c. Environmental Impacts: The use of alleys would have more of a negative impact on the environment than a street pattern without alleys. d. If site characteristics allow for the effective use of alleys. The maximum width of single loaded garage driveways shall not exceed nine feet (9') and double loaded garage driveways shall not exceed sixteen feet (16'). Staff Comment: Access for both proposed lots would be provided from future Road A, which is a new public street currently under construction as part of the adjoining Jones Short Plat (LUA20-000237) under construction permit C24002370. RMC 4- 6-060 requires that each lot within a Short Plat have access to a public street, either directly or via an approved shared access arrangement. Lot 1 would have direct frontage on both Park Ave N and future Road A, satisfying the minimum frontage requirement. Lot 2 would gain frontage and access solely from Road A, contingent on incorporation of the 2,473-square-foot tract located immediately south of Road A. This tract is to be consolidated into the subject property through a lot line adjustment with the adjoining parcel to the north prior to recording of the final plat. To ensure Lot 2 maintains compliant access to a public street, staff recommends as a condition of approval that the proposed lot line adjustment be recorded prior to final Short Plat approval. The lot line adjustment shall incorporate the 2,473-square-foot portion of APN 3342103215, identified as Tract B in the approved preliminary Jones Short Plat (LUA20-000237), into the subject property (APN 3342103250). Required frontage improvements along Park Ave N include pavement restoration, as needed to meet City standards, and the installation of curb, gutter, planter strip, Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 16 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL and sidewalk, consistent with RMC 4-6-060. Any necessary right-of-way dedication shall be provided to accommodate the full improvement section. To ensure circulation consistency and to reduce the number of driveway curb cuts onto Park Ave N, staff recommends, as a condition of approval, that Lots 1 and 2 shall take access exclusively from future Road A. The restriction shall be recorded on the face of the plat. N/A Blocks: Blocks shall be deep enough to allow two (2) tiers of lots. Staff Comment: Not applicable, as no blocks are proposed. Projects are exempt from block depth regulation when the location and extent of environmental constraints prevent a standard plat land configuration.  Lots: The size, shape, orientation, and arrangement of the proposed lots comply with the requirements of the Subdivision Regulations and the Development Standards of the R-6 zone and allow for reasonable infill of developable land. All of the proposed lots shall meet the requirements for minimum lot size, depth, and width. Width between side lot lines at their foremost points (i.e., the points where the side lot lines intersect with the street right-of-way line) shall not be less than eighty percent (80%) of the required lot width except in the cases of (1) pipestem lots (or flag lot), which shall have a minimum width of twenty feet (20') and (2) lots on a street curve or the turning circle of cul-de-sac (radial lots), which shall be a minimum of thirty five feet (35'). No residentially zoned lot shall have a depth-to-width ratio greater than four-to- one (4:1). Flag lots may be permitted for new plats to achieve the minimum density within the Zoning Code when there is no other feasible alternative to achieving the minimum density. Staff Comment: The proposed lots would comply with the minimum area and dimensional standards of the R-6 zone (see FOF 14, Zoning Development Standard Compliance). The lots are rectangular in shape. As previously conditioned above (see FOF 15: Design Standards), the primary entrance of the new residence to be constructed on proposed Lot 1 would be oriented west toward Park Ave N, but “front” facade design elements would be required on the north facade facing future Road A as well. Complaint if Modification approved under FOF 18 Streets: The proposed street system shall extend and create connections between existing streets per the Street Standards outlined in RMC 4-6-060 Street Standards. Staff Comment: Frontage improvements would be required along the site’s Park Ave N frontage. To meet the City’s complete street standards for Collector Arterial streets, the minimum ROW width would be 83 feet (83’) requiring a ROW dedication of up to 16.5 feet (16.5’). The applicant is proposing a modified street section for Park Ave N that includes a pavement width of 32 feet (32’) (measured from the existing west curb line in Park Ave N), an eight-foot (8’) wide planting strip, a five-foot (5’) wide sidewalk, and a one-half foot (0.5’) wide curb. The proposed improvements would result in a total ROW width of 57 feet (57’), requiring seven Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 17 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL feet (7’) of ROW dedication, pending final survey. On-street parking is provided along the development side of Park Ave N to include one (1) parking lane. The applicant submitted a request for a Street Modification to reduce the width of ROW dedication from 16.5 feet (16.5’) to seven feet (7’) (Exhibit 12). Staff is supportive of the modification request. See FOF 18, Modification Analysis for additional information. Each new lot is subject to a Transportation Impact Fee. The 2025 Transportation Impact Fee is $11,485.67 per single-family home. Assessed fees for the future home would be based on the City of Renton Fee Schedule at the time of Building Permit issuance. This fee is paid at the time of Building Permit issuance.  Relationship to Existing Uses: The proposed project is compatible with existing surrounding uses. Staff Comment: The proposed Short Plat is compatible with the surrounding land uses. The site is zoned Residential-6 (R-6) and is surrounded by existing single- family residential development to the north, east, and west. Park Ave N borders the site to the west, providing public access to the existing parcel. The proposed lot sizes are consistent with the character of the surrounding neighborhood and meet the minimum lot size requirements of the R-6 zone. The proposed density of 4.43 du/ac falls within the allowable range of this medium density zone. The proposed residential lots would maintain the mid-density residential character and are not anticipated to create any land use conflicts with abutting or adjacent properties in the Kennydale Community Planning Area. 18. Modification Analysis: The applicant is requesting a Street Modification from RMC 4-6-060F.2, Street Standards, for Park Ave N (Exhibit 12). Specifically, the applicant is proposing the following modification: modify the Collector Arterial Street standard along the subject property portion of Park Ave N. The alternative public street section includes a ROW width of 57 feet (57’) with a pavement width of 18 feet (18’) (measured from the right-of-way centerline), a ten-foot (10’) wide travel lane, an eight-foot (8’) wide parking lane, a one-half-foot (0.5’) wide curb, an eight-foot (8’) wide planting strip, a five-foot (5’) wide sidewalk and a one-half foot (0.5’) clear space behind the sidewalk. Dedication of approximately seven feet (7’) would be required pending final survey. The proposal is compliant with the following modification criteria, pursuant to RMC 4-9-250D.2, and all conditions of approval are met. Therefore, staff is recommending approval of the requested modification, subject to conditions as noted below: Compliance Modification Criteria and Analysis  a. Substantially implements the policy direction of the policies and objectives of the Comprehensive Plan Land Use Element and the Community Design Element and the proposed modification is the minimum adjustment necessary to implement these policies and objectives. Staff Comment: The Comprehensive Plan’s Land Use Element Goal LU-B is to “Support the development of Renton as a Regional Growth Center, consistent with VISION 2050, to foster compact, pedestrian-oriented, mixed-use development to meet the demands of population and employment growth while also increasing transportation efficiency and reducing negative environmental impacts.” Staff concurs the proposed Street Modification implements the policy direction of the Comprehensive Plan and is the minimum adjustment necessary. Community Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 18 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL design aspects of the Comprehensive Plan address walkable neighborhoods, safety, and shared uses. The intent of the policy is to promote new development with walkable places that support grid and flexible grid street and pathway patterns, and are visually attractive, safe, and healthy environments. The existing character of Park Ave N in the vicinity of the project is much more of a neighborhood street, with primarily existing single-family residences on both sides of the street and thus, it would be inappropriate to provide the standard Collector Arterial section in this area. Maintaining two (2) travel lanes instead of four (4) retains the more neighborhood character of the street (with many single-family properties with frontage on Park Ave N) instead of a technical arterial classification. Further, the modified street includes a planting strip and sidewalk consistent with residential street standards and therefore, the requested modification from the Collector Arterial standard is consistent with the policy guidelines noted above.  b. Will meet the objectives and safety, function, appearance, environmental protection and maintainability intended by the Code requirements, based upon sound engineering judgment. Staff Comment: City staff has reviewed Park Ave N and the surrounding area and have determined that a modified Residential Access Street section is suitable for this location on Park Ave N. Staff concurs the proposed Street Modification request achieves these standards as follows: • Safety: The proposed Street Modification does not have a negative impact on street safety. Although Park Ave N is classified as Collector Arterial, the volume of traffic is more consistent with the traffic volume of a Residential Access Street. Modifying the street section from Collector Arterial to Residential Access standard would not impact the safety function of the road. The applicant is still required to install safety elements like curbs, planters, sidewalks, and ADA ramps to provide a safety buffer for pedestrians and provide a continuous path of travel. These improvements are consistent with code requirements and provide a safer street section for both traffic and pedestrians. • Function/Appearance: The proposed Street Modification would provide an ADA accessible sidewalk and ADA ramps fronting the property, meeting the plan goals of providing a pedestrian oriented space. • Environmental Protection: The proposed modification reduces the street section, thus minimizing the overall disturbance in the ROW reducing the environmental impact associated with roadwork. Further, the modified street section would result in less impervious surface which reduces the surface water runoff and pollutant load associated with roadways. • Maintainability: The modified street section reduces overall paved surface area, thus reducing the City’s future maintenance costs.  c. Will not create substantial adverse impacts to other property(ies) in the vicinity. Staff Comment: Staff has not identified adverse impacts to other properties from the requested Street Modification. See also comments under criterion ‘b’.  d. Conforms to the intent and purpose of the Code; and. Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 19 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL Staff Comment: See comments under criterion ‘b’.  e. Can be shown to be justified and required for the use and situation intended. Staff Comment: See comments under criterion ‘b’. 19. Availability and Impact on Public Services: Compliance Availability and Impact on Public Services Analysis  Police and Fire: Police and Fire Prevention staff indicates that sufficient resources exist to furnish services to the proposed development; subject to the condition that the applicant provides Code required improvements and fees. The 2025 Fire Impact Fees are $421.98 per single-family unit. The fee in effect at the time of Building Permit issuance will be required.  Schools: It is anticipated that the Renton School District can accommodate any additional students generated by this proposal at the following schools: Kennydale Elementary, Risdon Middle School and Hazen High School (Exhibit 13). Any new students from the proposed development would be bussed to their respective schools. The bus stop is located approximately 0.5 miles from the project site at N 30th St and Park Ave N. The proposed project includes the installation of frontage improvements along the Park Ave N frontage, including sidewalks. Students would walk south along Park Ave N within the existing paved shoulder on the east side of the street until reaching the bus top at the intersection of Park Ave N and N 30th St. The intersection at Park Ave N and N 30th St is a four-way stop and provides crosswalks. A School Impact Fee, based on new single-family lots, will be required in order to mitigate the proposal’s potential impacts to the Renton School District. The fee is payable to the city as specified by the Renton Municipal Code. The 2025 School Impact Fee would be assessed at $1,003.00 (plus a 5% surcharge fee) per single- family residence, however the fee in effect at the time of Building Permit issuance would be required.  Parks: A Park Impact Fee would be required for the future houses. The current single-family Park Impact Fee is assessed at $3,276.44, however the Park Impact Fee in effect at the time of Building Permit issuance will be required.  Storm Water: An adequate drainage system shall be provided for the proper drainage of all surface water. Staff Comment: A Geotechnical Evaluation, prepared by Earth Solutions NW, LLC (ESNW), dated November 27, 2023 (Exhibit 10), was submitted with the application. The report describes soil and groundwater conditions on the site and provides recommendations for design and construction. The report concludes that infiltration is generally feasible, subject to compliance with the recommendations contained therein. A Preliminary Technical Information Report (TIR), prepared by CORE Design, Inc., dated October 16, 2024 (Exhibit 11), was also submitted. The site is located within the East Lake Washington drainage basin and is subject to the Peak Rate Flow Control Standard (matching existing conditions) under the 2022 City of Renton Surface Water Design Manual (RSWDM). The TIR identifies the project as subject to Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 20 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL a full drainage review addressing Core Requirements 1 through 9 and applicable Special Requirements. A Level 1 Downstream Analysis was included consistent with Core Requirement #2. With respect to Core Requirement #3 (Flow Control), the applicant claims an exemption from providing a flow control facility on the basis that the project would result in less than a 0.15 cfs increase in the 100-year peak flow over existing conditions. Staff concurs with the exemption at this stage based on the conceptual plan but notes that final confirmation will occur during Civil Construction Permit review. No conveyance system capacity analysis was provided with the preliminary submittal. A full backwater and conveyance system analysis consistent with Core Requirement #4 will be required at the time of Civil Construction Permit review. A Construction Stormwater Pollution Prevention Plan (CSWPP) (Core Requirement #5) and a Maintenance and Operations Manual (Core Requirement #6) must also be provided with the Civil Construction Permit application. For Core Requirement #8 (Water Quality), the TIR indicates that the project will result in less than 5,000 square feet of new plus replaced pollution-generating impervious surface and therefore qualifies for exemption from water quality treatment requirements. Staff concurs with this preliminary exemption but will re- evaluate compliance during construction permit review. Appropriate on-site Best Management Practices (BMPs) will be required under Core Requirement #9. The proposal has evaluated small lot BMPs as required by Section 1.2.9.2.1 of the RSWDM. Infiltration facilities, such as full infiltration drywells, must comply with Section C.2.2.2 of the 2022 RSWDM. Because the site is located within Aquifer Protection Area (APA) Zone 2, liners may be required in accordance with Sections 6.2.4 and 1.2.4.3 of the RSWDM. Infiltration devices are prohibited within 50 feet (50’) of steep slope, erosion hazard, or landslide hazard areas. The development is subject to stormwater system development charges (SDCs). As of 2025, the stormwater SDC rate is $0.94 per square foot of new impervious surface, with a minimum charge of $2,350, assessed on frontage, streets, parking, and sidewalks. In addition, each new single-family residence will be charged $2,350 per lot. Fees are payable at the time of Civil Construction Permit issuance and are not vested to the rates in effect at land use approval.  Water: There is an existing eight-inch (8”) ductile iron water main (Highlands 435 Pressure Zone) located in Park Ave N that can deliver a maximum flow rate of 2,500 gallons per minute (gpm). There is an existing 12-inch (12”) water main (Kennydale 308 Pressure Zone) located in Park Ave N (see City plan no. W-276809) that can deliver a maximum flowrate of 3,500 gpm. A dead-end eight-inch (8”) ductile iron water main (Highlands 435 Pressure Zone) shall be constructed under the Jones Short Plat project (C24002370) that will have a maximum flow capacity of 1,250 gpm along Road A, north of the proposed development. The site is located in a Zone 2 Aquifer Protection Area. The static water pressure is approximately 96 psi at ground elevation of 214 feet (214’). The 2025 Water System Development Charge (SDC) would be applicable for each proposed one-inch (1”) domestic water service at $5,025.00 per meter. Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 21 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL  Sanitary Sewer: Wastewater service is provided by the City of Renton. There is an existing eight-inch (8”) concrete pipe in Park Ave N (see city plan no. S-01790F). There is an existing six-inch (6”) sewer stub serving the parcel. The 2025 Water System Development Charge (SDC) would be applicable for each proposed one-inch (1”) domestic water service at $4,025.00 per meter. I. CONCLUSIONS: 1. The subject site is located in the Residential Medium Density (RMD) Comprehensive Plan designation and complies with the goals and policies established with this designation, see FOF 5 and FOF 13. 2. The subject site is in the Residential-6 (R-6) zoning designation and complies with the zoning and development standards established with this designation provided the applicant complies with City Code and conditions of approval, see FOF 6 and FOF 14. 3. Compliance with the Residential Design and Open Space Standards could not yet be demonstrated but would be verified at the time of formal Building Permit application review, see FOF 15. 4. The proposed Short Plat complies with the critical area regulations as established by City Code and state law provided all advisory notes and conditions are complied with, see FOF 16. 5. The proposed Short Plat complies with the subdivision regulations as established by City Code and state law provided all advisory notes and conditions are complied with, see FOF 17. 6. The proposed Short Plat complies with the street standards as established by City Code, provided the project complies with all advisory notes and conditions of approval contained herein, see FOF 17 and FOF 19. 7. The proposed Street Modification complies with the modification criteria as established by City Code, see FOF 18. 8. There are safe walking routes to the school bus stop, see FOF 19. 9. There are adequate public services and facilities to accommodate the proposed Short Plat, see FOF 19. 10. Key features integral to this project include the creation of two (2) new single-family residential lots in the R-6 zone; orienting the primary pedestrian entry of the future home on Lot 1 toward Park Ave N to reinforce neighborhood character and promote cohesive streetscape design; and prompt recording of the proposed lot line adjustment to ensure Lot 2 has access to a public street. J. DECISION: The Jones Renton Short Plat - South, File No. LUA25-000111, SHPL-A, MOD, as depicted in Exhibit 2, is approved and is subject to the following conditions: 1. The primary pedestrian entry of the future dwelling on Lot 1 shall face Park Ave N and the primary pedestrian entry of the future dwelling on Lot 2 shall face future Road A. The orientation requirement shall be noted on the face of the final Short Plat. 2. The setback designations applied to Lot 2 shall be the following: the north property line shall be considered the front yard setback, the south property line the rear yard setback, and the east and west property lines the side yard setbacks. Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 22 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL 3. The applicant shall submit a detailed landscape plan at the time of Civil Construction Permit review. The detailed landscape plan shall identify individual plant species and quantities in all landscaped areas of the site, as well as the street planter strip, and shall be submitted to the Current Planning Project Manager for review and approval prior to the issuance of a Civil Construction Permit. 4. The applicant shall submit a detailed landscape plan at the time of Civil Construction Permit that documents compliance with the tree credit requirements in RMC 4-4-130H.1.b. The detailed landscape plan shall be reviewed and approved by the Current Planning Project Manager prior to permit issuance. 5. The proposed lot line adjustment shall be recorded prior to final Short Plat approval. The lot line adjustment shall incorporate the 2,473-square-foot portion of APN 3342103215, identified as Tract B in the approved preliminary Jones Short Plat (LUA20-000237), into the subject property (APN 3342103250). 6. Future Lots 1 and 2 shall take access exclusively from future Road A. The restriction shall be recorded on the face of the plat. DATE OF DECISION ON LAND USE ACTION: SIGNATURE: Matthew Herrera, Planning Director Date TRANSMITTED on November 7, 2025 to the Owner/Applicant/Contact: TRANSMITTED on November 7, 2025 to the Parties of Record: Duwamish Tribe 4705 W Marginal Way SW Seattle, WA 98106 TRANSMITTED on November 7, 2025 to the following: Gina Estep, CED Administrator Justin Johnson, Acting Development Engineering Director Stephanie Rary, Property Services Specialist Clark Close, Current Planning Manager Nate Janders, Development Engineering Manager Anjela Barton, Fire Marshal Owner/Applicant: Contact: Park Ave 5 LLC 4044 148th Ave NE Redmond, WA 98052 Kevin Rech 3412 210th PL NE Sammamish, WA 98074 Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 11/7/2025 | 2:38 PM PST City of Renton Department of Community & Economic Development Jones Renton Short Plat - South Administrative Report & Decision LUA25-000111, SHPL-A, MOD Report of November 7, 2025 Page 23 of 23 D_Admin Decision_Jones Short Plat South_251104_v4_FINAL K. LAND USE ACTION APPEALS, REQUEST FOR RECONSIDERATION, & EXPIRATION: The administrative land use decision will become final if the decision is not appealed within 14 days of the decision date. APPEAL: This administrative land use decision will become final if not appealed in writing to the Hearing Examiner on or before 5:00 PM on November 21, 2025. An appeal of the decision must be filed within the 14-day appeal period (RCW 43.21.C.075(3); WAC 197-11-680). Appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov or delivered to City Hall 1st floor Lobby Hub Monday through Friday. The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date if your appeal is submitted electronically. The appeal submitted in person may be paid on the first floor in our Finance Department. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov. EXPIRATION: The Administrative Short Plat decision will expire five (5) years from the date of decision. A single one (1) year extension may be requested pursuant to RMC 4-7-070M. RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be reopened by the approval body. The approval body may modify his decision if material evidence not readily discoverable prior to the original decision is found or if he finds there was misrepresentation of fact. After review of the reconsideration request, if the approval body finds sufficient evidence to amend the original decision, there will be no further extension of the appeal period. Any person wishing to take further action must file a formal appeal within the 14-day appeal time frame. THE APPEARANCE OF FAIRNESS DOCTRINE: provides that no ex parte (private one-on-one) communications may occur concerning the land use decision. The Doctrine applies not only to the initial decision, but to Appeals to the Hearing Examiner as well. All communications after the decision/approval date must be made in writing through the Hearing Examiner. All communications are public record and this permits all interested parties to know the contents of the communication and would allow them to openly rebut the evidence in writing. Any violation of this doctrine could result in the invalidation of the appeal by the Court. Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99 CITY OF RENTON DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT ADMINISTRATIVE REPORT & DECISION EXHIBITS Project Name: Jones Renton Short Plat - South Land Use File Number: LUA25-000111, SHPL-A, MOD Date of Report November 7, 2025 Staff Contact Alex Morganroth Principal Planner Project Contact Kevin Rech 3412 210th Pl NE Sammamish, WA 98074 Project Location 3215 Park Ave N, Renton, WA 98056 (APN 3342103250) The following exhibits are included with the Administrative report: Exhibit 1: Administrative Decision Exhibit 2: Site Plan Exhibit 3: Boundary & Topographic Survey Exhibit 4: Preliminary Landscape Plans Exhibit 5: Grading, Storm Drainage, and Utility Plans Exhibit 6: Construction Mitigation Description Exhibit 7: Preliminary Tree Retention & Replacement Plan Exhibit 8: Tree Retention and Credit Worksheet Exhibit 9: Tree Assessment, dated September 26, 2023 Exhibit 10: Geotechnical Evaluation, prepared by Earth Solutions NW, LLC (ESNW), dated November 27, 2023 Exhibit 11: Preliminary Technical Information Report (TIR), prepared by CORE Design, Inc., dated October 16, 2024 Exhibit 12: Street Modification Request, dated August 24, 2024 Exhibit 13: Renton School District Letter Exhibit 14: Duwamish Tribe Comment, dated May 2, 2025 Exhibit 15: City Response to Duwamish Tribe Comment, dated May 6, 2025 Exhibit 16: Advisory Notes Docusign Envelope ID: FD5DD306-22FD-4B99-B71E-865ED9AD1A99