Loading...
HomeMy WebLinkAboutR-427607co N LU 1 I— DocuSlgn Envelope ID 345B681D-914F-4F2D-AB59-7C192D3878A3 r� EX. SEWER MAIN i I I I i l PROPERTY LINE F��FWESR I I I IAS NEEDED) II II, 3'-0' MIN —1WER STUBFUTURE 4" SIDE SEWER 2"x 4" STUD MARKING POST PAINTED 6" CAP f WHITE WITH THE WORD "SEWER" STENCILED TEE X 6" TEE 1 I i i I IN 3" HIGH BLACK LETTERS AND #6 WIRE SIDEWALK i ? WRAPPED AROUND THE STUD AND I 1 1 I EXTENDED TO THE TOP OF THE STUD I 1 1 tag COUPUNG(TYP) L_J_L_________J a 13 6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER CI (EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR APPROVED EQUAL, SPECIFY -SEWER" ON LID), L5 CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD CONCRETE PAD TO BE 8" IN DEPTH r - ----------------------- BEND AS REQUIRED EXISTING SANITARY _ SEWER MAIN ., n.r u1N SLOPE -� N6" SEWER STUB `6"x6"X6" WYE `FUTURE 6"x 4" REDUCER `SEWER MAIN SIZE X 6" TEE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL) C PVC h C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) 0. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC ), CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). F HDPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL NOTES. i PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT 2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER 3 SIDE SEWERS SHALL HAVE A MINIMUM 2 S SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR 4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT THE APPOINTED TIME DO NOT BACKFlLL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR 5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102 6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405 7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON SIDE SEWER STUB STD. PLAN -406.1 • PUBLIC WORKS APP�8bP�a"� INSTALLATION � DEPARTMENT Martin PastuCh@Y26/202 (SEWER MAIN TO PROPERTY LINE) NB9aJJ D988449D OATS �� s 9 i CEMENT CONCRETE slDEwxx CEMENT CONCRETE .r-- CURB a GUTTER (SEE NOTE 3) ij DEPRESSED MONOLITHIC % CURB a GUTTER ETAIL (SEE DTHS SHE.ET) TYPE C28, - ISOMETRIC VIEW (COMMERCIA'., WITH BUFFER) NOTES 1. When a driveway width exceeds 15 fee; construct a full depth expansion Joint with 3/8' Joint filler sk)ng the driveway lane lines (see std. plan 102). Construct expansion Joints parallel with the centJsrilne as required at 15' maximum spacing when driveway widths exceed 30'. 2. See std. plan 102 for sidewalk details. 3. Curb and gutter shown, other curb designs may be specified. See std. plan 101 for curb details. 4. Not used. 5. The engineer Will design all driveways to Include eavatlons at all points marked with symbol "X". All elevations are at the back of curb top on uphill aide. 6 Not used 7 For Driveway W dths see DRIVEWAY STANDARDS (See NOTE 10). The expansion joints (see Vb plan 102) shall be spaced as shown In the corresponding isonneItllC New. FACE OF CURB BEE 9, BEE OEFREbSm G.'RH OETA! CONTRACTION JOINT e ur ON P"15 SHEET STO PLAN 102 i tom. r , b tltR TOAC _ RWCwAY ,I I a .• - A .. Iir I _ _ 1 r 11" NOTE. OfVVEWAYLOMITUDINALEVANSON JOIN78 SWUL BE FULL DEPTH DEPRESSED IMONOLfTHIC CURB A OUTER DETAIL 8. Slopes shell comply with sections RI I or R303.2.2 or - FACE OF ADJACENT CURB R3032.3 of the Revised Draft Guidelines for Accessible Public r 1! Rights -of -Way of November 23, 2005 (PROWAG). �' J�� i 9. Curb returns for any Type C-MAX Driveway may be approved on a case -by Case basis. ' 1�R GUTTER SURFACE 10, STREET STANDARDS = Renton Municipal Code (RMC) Tnle IV Development Regulations CHAPTER 6 STREET AN D UTILITY STANDARDS Section 4-"60STREETSTANDARDS DEPRESSED B DETAIL AT RESIDENTIAL OR COMAW4= DRIVEWAYS, AND ALLEYS DRIVEWAY STANDARDS = Renton Municipal Code (RMC) _ Driveway Example: TYPECIS Title IV Development Regulations CHAPTER 4 R-Redd d C-GomrerCal i CITY-WIDE PROPERTY DEVELOPMENT STANDARDS NMmbe of4nea. -- Section 4-4-M PARKING, LOADING AND DRIVEWAY (MI Lane C4I11R1reIB4 REGULATIONS a.&" rw " "I wa"iFftB — J CEMENT CONCRETE DRIVEWAY 3rPLAN - 1042 O` ° ENTRANCES - NOTES AND DETAILS ITFi. C l6 N _ I"""""""""TH0S C I V I L wEngineering Entitlement Project Management H o OL ethoscivil.com info@ethoscivil.com 253.414.1989 1 12: DocuSlgn Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3 ALL 90 TURNS SHALL BE ACCOMPLISHED BY MEANS OF A WYE WITH CLEANOUT AND 4" BEND AS REWIRED (NO GREATER 45 BEND TWO 45• SENDS SHALL NOT BE THAN 45• BEND) EVERY 2N0 CHANGE 4" CLEANOUT WYE WITH ACCEPTABLE (SEE NOTE 11) IN DIRECTION OR GRADE WILL REWIRE 45 BEND AND PLUG A CLEANOUT WYE (SEE NOTE 11) I (SEE NOTE 11) z z z HOUSE g I a HOUSE ill a HOUSE $I a HOUSE ' 3 -0" MIN 4" SEWER PIPE SURFACE CLEANOUT 4" SURFACE 'a (TYPICAL) 6"z 6"x6" WYE ~ CLEANOUT 4" SEWER PIPE, SEE NOTES 2 (SEE STD PLAN - 407) �'E �4„ � 4" TEST TEE WITH AND 3 MINIMUM LINE SIZE FOR WYE NTH PLUG FACE UP OTHER THAN SINGLE FAMILY IS 6" R 0 W LINE CLEANOUT (TYPICAL) ROW LINE 3' MIN 6"x 4" REDUCER N N N (TYPICAL) N MAIN SEWER LINE in x k NOTES z IF THE BUILDING SEWER SERVES ANY FIXTURE HAVING FLOOD LEVEL RIMS LOCATED BELOW THE ELEVATION < a<(4" 1 PRIOR TO INSTALLATION OF A SANITARY SEWER CONNECTION, A z oOF THE NEXT UPSTREAM MANHOLE COVER OF THE SIDE -SEWER PERMIT MUST BE PURCHASED FROM THE CITY OF vPUBLIC SEWER SYSTEM, A BACKFLOW PREVENTION RENTON PUBLIC WORKS DEPARTMENT. b z1 SUCH AS CLEAN CHECK EXTENDABLE aDEVICE toBACKWATER VALVE OR APPROVED EQUAL SHALL BE 2 FOR INSPECTION OF SIDE SEWER, CALL 24 HOURS IN ADVANCE mINSTALLED THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER PERMIT FLEXIBLE COUPLING (FERNCO OR EQUAL) SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE O4" ON SITE WHEN INSPECTOR ARRIVES AT APPOINTED TIME DO NOT o' BACKFlLL THE DITCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR 5 WSURFACE CLEANOUT m 4"x 4"z4" WYE 3 SIDE SEWER PIPE AND FITTINGS SHALL BE PVC SDR 35 WITH RUBBER PIPING GASKET JOINTS UNLESS OTHERWISE APPROVED BY THE PUBLIC PLAN WORKS DEPARTMENT BUILDING DRAIN FOR 4 A MINIMUM GRADE OF 2R (1/4" PER FOOT) MUST BE MAINTAINED LOW ELEVATION HOUSE WITH A 4" PIPE IN THE EVENT A 2X GRADE CANNOT BE MAINTAINED WITH THE APPROVAL OF THE PUBLIC WORKS INSPECTOR, THE MAIN TO CONTRACTOR MAY INSTALL A 6" DIAMETER SIDE SEWER AT NO LESS 5 FEET R 0 W LINE R 0 W. LINE TO CLEANOUT MAX THAN 1S. SIDE SEWER BUILDING SEWER BUILDING STUB RA DRAIN 5 INSTALL SIDE SEWER WITH 2' MINIMUM COVER 18" COVER IS ALLOWED 3 FEET MIN 1-- AT THE HOUSE IF OUTLET IS SHALLOW 6 ALL BUILDING SEWER AND SIDE SEWERS SHALL HAVE BEDDING IN / I�� ACCORDANCE WITH STANDARD PLAN 405 IL, JII�IQ, N �♦ A ��VI ;I m t c = x s = = A x ,y ° 7 WHENEVER FEASIBLE, THERE SHALL BE A MINIMUM 5 FOOT LA rmn s z'1 + Z n'+ :9 fTi s z m 4 a In HORIZONTAL SEPARATION BETWEEN SANITARY SIDE SEWERS AND ALL I m ^A, �: = 1 + � no x 8 o OTHER UTILITIES azi q� v m A i m v. n ♦ CT O1 $o c z m "' m 8 SIDE SEWER TESTING SHALL CONSIST OF PLACING A PLUG IN THE CZT m m"t os 0 om s TEST TEE AND INSTALLING A 4-FOOT RISER PIPE ON THE z o 08 CLEANOUT I o _ i g AT THE BUILDING. THE SIDE SEWER PIPE SHALL BE FILLED TO WITH m i y cT m .� 3 WATER TO THE TOP OF THE RISER PIPE NO LOSS OF WATER SHALL n OCCUR FOR A PERIOD OF 10 MINUTES. THE SIDE SEWER MAY BE z 0 CONNECTED TO THE BUILDING FOLLOWING THE SUCCESSFUL 0t a, COMPLETION OF THE LEAK TEST 9 THE CLEANOUT AT THE RICHT-OF-WAY SHALL BE INSTALLED PER m PLAN STANDARD PLAN 4061 THE CLEANOUT AT THE BUILDING SHALL BE BUILDING SEWER INSTALLED TO SURFACE GRADE ALL OTHER CLEANOUTS SHALL BE INSTALLATION INSTALLED TO WITHIN 12" OF THE SURFACE 10 IF SIDE SEWER STUB IS NOT AVAILABLE THE OWNER SHALL BE RESPONSIBLE FOR ITS INSTALLATION PER STANDARD PLAN 4061 ALL WORK '"THIN STREET RIGHT-OF-WAY SHALL BE DONE BY A LICENSED AND BONDED CONTRACTOR CALL 811 BEFORE YOU DIG 11 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC or go t0 RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102 www collbeforeyoud.g Org 12 ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT (WSHA) TYPICAL BUILDING SEWER {�..R STD. PLAN -406.2 PUBLIC WORKS APPROVED DEPARTMENT FROM PROPERTY LINE TO Martin PastUClJ§/26/202 BUILDING CONNECTION 869491FD98B4490 DATE aB)'TEu 1B6lU0E551DEWAlKiWW9i_ - _ a' Mw Y W E8 fBE! NOTE Tz s k1P (BEE NONE ai - — —_ - _' TSEE NOIEa pRM'WAY iiiiL NE0 110'EA►ANSONJOwi (TYP4 HBEE STp PIAN 13h CE [C SC z BEE MJT[S � 41 EW ICRETE :WALK u " SEE NOTE 1 CEMENT CplICRETE J RAs.V MTNLOPEIYPI B CVRBBGOTE31 SLOPE ITYP.1 SEE NOTE 31 la. CONTwAcrnxr xlrIT (TYP 1 I65 S1O PUN HIT1 PLAN VIEW VAPoEB TSEE NOTE 10 ■3%UU SEE NOR B ITYPI TIEWN1 CONCRETE a'AeN [meWill 31 BBGUTRR SIDEWALK 3e' ExPMS10H xx"i I}iP 1 16EE lore II _ SECTION O .BEE SID.PUN IOI ' ... 1R emn, _ 410EWAtx Y.IDM 1G\ DIFFERENCE N SLOPE r.MA -DRNEWAY W P'4rTVE SLOPE ISLOPE SNOYM EX4G ARATE01 1871 13% IWVBYGYT-.8.�,• ryz NEGATIVE S oGO RELAnVE SLOPE $TIED 6HOYM E%AGGE�TEO$ 1 � - i CEMENT C ONCRE E SIDEWALK TYPE R18 - ISOMETRIC VIEW (RESIDENTIAL WITH BUFFER) CEMENT CONCRETE CURS S GUTTER ISee NOTE 31 For NOTES STD PLAN 104.2 STD. PLAN - 104.3 + 4 PUBLIC WORKS CEMENT CONCRETE DRIVEWAY PPR F,D: >=„ DEPARTMENT ENTRANCE - TYPE RIB MeWn / Z fly 03/11/2024 NO. Gregg Z—L-rman, PUbIsc Works Administrator REVISION 12: MAIN FINISHED GRADE 9" TO 12" A 4 \ 24" TO 30" A /y 22 Y2 i LOOP DOWN TO CENTERLINE OF WATER MAIN TO PROVIDE SLACK IN SERVICE LINE TO METER w z w z } IN UNIMPROVED ROW, w INSTALL METER BOX w CITY PRIVATE p AT PROPERTY LINE WITH p a 1" COPPER TAILPIECE at PIPING PIPING SIDEWALK i/ u 12" 21" TO 30" 9 MATERIALS 1" BALL CORPORATION STOP WITH BALL VALVE, AWWA TAPERED THREAD (CC) INLET, QUICK JOINT OUTLET, OA CORPORATION STOP FORD FB1000-4-Q-NL OR A.Y. MCDONALD 74701BQ O TUBING 1" TYPE T' SOFT COPPER TUBING 1" SETTER, QUICK JOINT INLET AND OUTLET, PADLOCK WINGS ON INLET ANGLE BALL VALVE, SINGLE CHECK METER SETTER VALVE ON OUTLET, FORD VBH74-15W-44-44-Q-NL, A.Y. MCDONALD 721-415WCQQ 44, OR MUELLER B-24701-6AN, INSTALL CENTERED AND SQUARED IN METER BOX, PROVIDE ADAPTERS FOR 5/8"x3/4" METERS OD WATER METER AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BY THE CITY O METER BOX METER BOX, ARMORCAST A6001946PCX18, WITH METER BOX LID, ARMORCAST A6001969RCI-H7, TO READ "RENTON WATER" O COUPLER AND PLUG COUPLER (PACK JOINT x PACK JOINT), FORD C4#-4#-Q-NL, WITH 1" GALVANIZED PLUG IF SERVICE LINE TO PROPERTY IS TO BE INSTALLED IN THE FUTURE O GRAVEL 1 V4" WASHED GRAVEL PUBLIC WORKS DEPARTMENT 1" WATER SERVICE DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 UNDISTURBED NATIVE VEGETATION UNDISTURBED NATIVE SOIL 3"A" ARBORIST WOOD CHIP MULCH, SEE STD. PLAN 262.60 3" OF COMPOST INCORPORATED INTO 5" OF SITE SOIL (TOTAL AMENDED DEPTH OF 9.5", FOR A SETTLED DEPTH OF 8") SUBSOIL SCARIFIED 4" BELOW COMPOST AMENDED LAYER (12" BELOW SOIL SURFACE) 3"4" ARBORIST WOOD CHIP MULCH, SEE STD. PLAN 262.60 6" IMPORTED TOPSOIL MIX (COMPACTED DEPTH) SUBSOIL IS SCARIFIED 6" BELOW IMPORTED TOPSOIL MIX PLANTING BEDS/UNDISTURBED SEENOTE UN ISTURBED TURF (LAWN) AREAS, VEGETA I(Iil�lA1�IIII1�111�)�,I�I�)I��IIII NOTE 1 1GRASS: SEED OR SOD 0 OPTION 1 - NO DISTURBANCE PLANTING BEDS 0" 8" STD. PLAN - 320.1 OVED: 6/28/2023 Nscucna DATE hz Administrasm UNDISTURBED NATIVE SOIL TURF (LAWN) AREAS �1}� IIII ����III�II�I,ll�ll �l^��II!�II��I I GRASS: SEED OR SOD 1.75" OF COMPOST INCORPORATED INTO 6.25" OF SITE SOIL (TOTAL AMENDED DEPTH OF 9.5", FOR A SETTLED DEPTH OF 8") SUBSOIL SCARIFIED 4" BELOW COMPOST AMENDED LAYER (12" BELOW SOIL SURFACE) OPTIONS 2, 3, AND 4 - AMEND IN PLACE OR STOCKPILE AND AMEND PLANTING BEDS I TURF I(LAi,WIN)AREAS I GRASS: SEED OR SOD p• =m 1 #111=III=11 f NOTES: III i 1=1 I -III -I i�i—III III III "' 1. AREAS OF NO DISTURBANCE TO BE FENCED AND EXISTING VEGETATION AND SOIL TO BE �111 PROTECTED FROM CONSTRUCTION IMPACTS. I1 -1 I -I I� I � 6"IMPORTED LL 11 II —III II TOPSOIL MIX GENERAL NOTES: (COMPACTED 6„ DEPTH) 1. TO MEASURE SETTLED DEPTH, WATER SOIL SUFFICIENTLY TO FULLY SATURATE WITHOUT CAUSING EROSION SUBSOIL IS SCARIFIED 6" 2. COMPOST TO MEET STD. PLAN 262.60. BELOW IMPORTED 3. COMPACTION OF TOPSOIL (WHERE REQUIRED) TO TO OF STANDARD TOPSOIL MIX BE 85% PROCTOR. T SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. OPTION 5 -IMPORTED TOPSOIL UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 264.00 PUBLIC WORKS APPR ED: DEPARTMENT SOIL AMENDMENT SECTIONS GqZ 9/28/2018 1 P.b1,­,k,Ad.,­I­ SURVEYED: ENCOMPASS DESIGNED: AE DRAWN: AE/NB CHECKED. AE BY DATE APPR APPROVED. AE SCALE: NTS ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM FROM METER TO BUILDING NOTE: 1. WHERE THE PRV ASSEMBLY IS INSTALLED ON AN EXISTING SERVICE, THE EXISTING SERVICE SHALL BE CUT AND NEW COPPER TUBING AND BRASS FITTINGS SHALL BE INSTALLED AS REQUIRED. MATERIALS OPRESSURE REDUCING PRV ASSEMBLY WITH INTERNAL BYPASS AND STRAINER, ZURN WILKINS 600XL SERIES OR EQUAL (FNPT) VALVE ASSEMBLY B PIPE BRASS NIPPLE MNPT LENGTH TO FIT OC SHUTOFF VALVE BRONZE BALL VALVE, ZURN WILKINS 850XL SERIES OR EQUAL (FNPT) O BEND 90" BRASS BEND (FNPT x PACK JOINT) OE PIPE TYPE "K" SOFT COPPER TUBING, LENGTH TO FIT OBEND 90- BRASS BEND (PACK JOINT x PACK JOINT) OG BOX AND LID BN24" BOX AND LID, CONCRETE POLYMER OR HDPE OH GRAVEL 1 Y4" WASHED GRAVEL O PVC PIPE PVC NIPPLE, LENGTH TO FIT �•- ,� PUBLIC WORKS DEPARTMENT INDIVIDUAL PRESSURE REDUCING VALVE ASSEMBLY (RESIDENTIAL) STD. PLAN - 340.4 APPROVED: 6/28/2023 Martin Puwcne DATE P"Mk Works AtlminisHaror R-427607 r r O O N LJ IN COMPLIANCE WITH CITY OF RENTON STANDARDS :45 An O LL 0 o PR23000116 U) Z Know what's below. 0 call before you dig. B23004862 z LU DATE: AGUILAR RENTON SFR 03/11/2024 CITY OF OFFSITE IMPROVEMENTS PAGE: < RENTON e DRAWING NO: 1 Planning/Building/Public Works Dept. R2.03 ( STANDARD DETAILS SHEET ? OF Q a