Loading...
HomeMy WebLinkAboutS-4330020 m SE 1/4 SECTION 3, TOWNSHIP 23 N, RANGE 5 E, W.M. SOLERRA N , ' o -t 8 " P VC ( ) " 2-9.5 ; W W ; ''� yr v �� TRACT C010N, CONNECT NEW 8-INCH 70 EXIS77NG MANHOLE. CONNECTION \ \ S - a ' / 27 20 %9 \ ,/ » foo 18 L SHALL BE MADE USING � 22 � KOR-N-SEAL BOOTS OR 1 72 LF 8" PVC ® .93x T / \\ APPROVED EQUAL. MANHOLE I \ `� MA Y NEED TO BE x 1 l T T RE -CHANNELED. LADDER MAY // y� T-------------\�------- T T \ ,' NEED TO BE RELOCATED. STA. 10+16.99, 49.58' L a \ ,° p a a p. v° a - Arc b a p p a p RIM 436.43 8" 1E IN 429.60 (SW)-- 8" IE IN 429.53 (W) 8" IE OUT 429.50 (N) 54 LF 8" PVC ® 1.323g 1 \ �i I . ° \ I 3 " 231 LF 8 PVC ® 2.62R' U- SSMH 2 48" a 4 ROAD SSMH 1 48" - - - ° STA. 11 + 15.1I J. 442. L 1 \ \ SSMH 3 48" 6 STA. 10+45.13, 6.67' L \ \ " RIM 44279 STA. 12+09.09, 3.40' L °� M RIM 4J8.41 8 /E IN 434.79 (SW) _ R/M 450.35 _ 1 / P o ° a Uj 8" 1E IN 430.41 (S) I a 8" 1E OUT 434.69 (N) , - - ' \ 8" IE IN 442 35 (S) 8" IE OUT 430.31 (NE) a I II _ _ - - ' \ ,8" 1E OUT 442.25 (NE) a '.- 4 a. -� I ® / -_ p 0 UTIE DRAINAGE ESMT. - - 3 T T 4 - 5 6 SSMH nq��' RE NO. 8709231174 -1I A A A A-7 -71 \'A i II I I II H.P. ELEV = 451.52 H.P. STA = 12+38.45 PW STA = 12+00.95 PW ELEV = 450.59 A.D. - 6.50.E 460 K 12 ' 460 75 VC PROPOSED GRADE CENTERLINE OF ROAD N 455 177 CENTERLINE OF ROAD m Wdi 455 H.P. V ?99 ----------------------------- ---- H.P. TA ???450 --------------450 ---------- Q- PW STA= 10+64.16 p PW V = 438.27 -------------- - W A.D. = 11.00% - ----------- -- 29S = 3 - it .00' VC -- ------------------- ----- LF PVC ® 2.62?d 8 " g 231 io (0 ,� 445 o°p + 9. - � Ln 0 W STORM 0 $EO mu 12•PR .00 440 93�F8 - - p PROP0 SSMH 3, 48cz STA. 12+09.09, 3.40' L 435 I R/M 35 8" lE IN 442. (S) V 435 8 /E OUT "2.2 (NE) , i 430 - _ 2, 48 SSMFT " ? �� 430 STA. 11+15.14, 3.82' L RIM 442.79 8" 1E IN 434.79 (SW) COR MH4544 48" SSMH 1, 48" 8" /E OUT 434.69 (N) Q STA. 10+16.99, 49.58' L STA. 10+45.13, 6.67' L 425 -fR/M 436.43 RIM41 425 8 /E /N 0.41 S 8" IE /N 429.60 (SW) 8" IE IN 429.53 (W) 8" lE OUP430.31 (NE) 8" 1E OUT 429.50 (N) 54 LF 8" PVC ® 1.32% CONNECT NEW 8-INCH TO EXIS77NG MANHOLE. CONNECTON 420 SHALL BE MADE USING 420 KOR-N-SEAL BOOTS OR APPROVED EQUAL. MANHOLE MA Y NEED TO BE RE -CHANNELED. LADDER MAY NEED TO BE RELOCATED. ROAD A 1A) . in O 1� O ^ co 1n O 1� O h O O . O Of N N o� ' of �n O to O -' O O O v- O o h O h r\ O O N h n Oj Of QO n op Ci � N � N- Di " O •� 00 N � N M � � � � L � h 9+60 4 At Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) 10+00 10+40 03/2025 10+80 11+20 11+60 12+00 12+40 12+80 13+20 1 CITY COMMENTS (03.11.2025) BD 04.02.25 YLP SURVEYED: SCALE: VERTICAL: NAD 1983/1991 D 1988 D.R. STRONG 2 CITY COMMENTS 06.27.2025 BD 07.03.25 YLP DESIGNED: AS NOTED HORIZONTAL: CONSUL TING ENGINEERS BD ENGINEERS PLANNERS SURVEYORS DRAWN: PHB ONE INCH DATUM 620 - 7th AVENUE KIRKLAND, WA 98033 CHECKED: YLP AT FULL SCALE 0425827.3063 F425.827.2423 IF NOT ONE INCH N 0. REVISION BY DATE AP P R I APPROVED: YLP SCALE ACCORDINGLY 13+60 14+00 VRC TY 0 E RENTON Planning/Building/Public Works Dept. NORTH GRAPHIC SCALE 0 10 20 40 1 INCH = 20 FT. HORIZONTAL 0 2.5 5 10 1 INCH = 5 FT VERTICAL SEWER MANHOLE NOTES: SEWER MANHOLES PER COR STD PLAN 400.1 MANHOLE FRAME AND COVER PER COR STD PLAN 401 UTILITY CROSSING LEGEND: SEE TABLE ON SHEET C12 FOR UTILITY CROSSING TABLE AND DESIGN INFORMATION. ONLY SEWER UTILITY PLAN IS REVIEWED ON THIS PLAN SET, ALL OTHER ELEMENTS (E.G. ROAD, GRADING) SHOWN ON THE PLAN SET IS REVIEWED AND APPROVED UNDER SEPARATE PERMIT FROM KING COUNTY. S-433002 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING ` %' IL yqi 08/07/2025 ' WASTEWATER UTILITY jstowell08/05/2025 ' DATE: SO LE R RA 09.16.2024 SANITARY SEWER PLAN & PROFILE PAGE: OOK: PAGE: 10823, 10815, 10824 145TH PL SE C7 RENTON, WASHINGTON 98059 SHEET:7 OF:12 DRS PROJECT NO. 23033 L J co C) N MJ co O O N Q LU J 0 Cl)