Loading...
HomeMy WebLinkAboutS-4330030 SE 114 SEC TION 3 TOWNSHIP 23 N. RANGE 5 E, W.M. SOLERRA N „ Q a I\ � 4j 1CO 1 v, W J O � o STA. 14+40.16, 3.92' L RIM 456.49 8" IE IN 448.49 (S) 8" IE OUT 448.39 (N) SEE RIGHT NORTH GRAPHIC SCALE 0 10 20 40 1 INCH = 20 FT. HORIZONTAL 0 2.5 5 10 1 INCH = 5 FT. VERTICAL EXIS77NG GRADE 0 CEN7FRUNE OF ROAD 470 470 PROPOSED GRADE 0 CEN7ERUNE OF ROAD 465 465 460 460 2.50X _--- 12"PR p�p STORM --- --- - ------ 455 --- ---------- 227 LF 8" PVC 0 450 450 O O SSMH 5, 48" STA. 16+50.04, 38.97' L • 445 V co n RIM 461.67 8" IE IN 453.67 (W) 8" IE OUT 453.57 (N) Lu 445 SSMH 4, 48" W STA. 14 40.16, 3.92' L Q Z y CO 440 Z 8" IE IN R448.49 (S) 1U8" lE T 448.39 (N) 440 Uj 435 435 430 430 ROA D A N n Ln d- Ln Ln n Ln Ln N Ln O L Ln d W) c6 N O LO � L() h Ln O 00 h od Ln N o d M 14+00 Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) 14+40 14+80 111116— --...O�A 03/2025 15+20 15+60 D.R. STRONG 1 CONSUL TING ENGINEERS 2 ENGINEERS PLANNERS SURVEYORS 620 - 7th AVENUE KIRKLAND, WA 98033 04258273063 F 425.827.2423 N0. 16+00 CITY COMMENTS (03.11 CITY COMMENTS (06.2, REVISION 16+40 16+80 ONLY SEWER UTILITY PLAN IS REVIEWED ON THIS PLAN SET, ALL OTHER ELEMENTS (E.G. ROAD, GRADING) SHOWN ON THE PLAN SET IS REVIEWED AND APPROVED UNDER SEPARATE PERMIT FROM KING COUNTY. BD 04.02.25 YLP SURVEYED: BD 07.03.25 YLP DESIGNED: BD DRAWN: PHB rAPPROVED: ECKED: YLP BY DATE APPRYLP SEWER MANHOLE NOTES: SEWER MANHOLES PER COR STD PLAN 400.1 MANHOLE FRAME AND COVER PER COR STD PLAN 401 UTILITY CROSSING LEGEND: SEE TABLE ON SHEET C12 FOR UTILITY CROSSING TABLE AND DESIGN INFORMATION. SCALE: VERTICAL: NAVD 1988 AS NOTED HORIZONTAL: NAD 1983/1991 C T Y OF 11 RENTON (;R ONE INCH DATUM AT FULL SCALE ,Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY SEE LEFT EXIS77NG GRADE 0 CEN7FRL/NE OF ROAD 470 PROPOSED GRADE CEN7FRLINE OF ROAD -M5 465 R�O� gTOR 12" 0 460 I 460 " ATER ® 4 41 „p C LF 8 14`f 455 455 SSMH 6 48" STA. 17+36. 3, 75.91' R O RIM 468.11 6" IE IN 460.11 (SW) 450 I 8" IE OU 0.01 (E) 450 • . = SSMH 5, 48" QCa STA. 16+50.04, 38.9 L co CO- RIM 461.67 8 IE IN 453.67 (W) = 8" IE T 453.57 (N) 445 W c 445 ' Uj W Z ca 440 ROA D A W o o 0) � 16+40 16+80 17+20 17+60 S-433003 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NORTH 0 10 20 40 1 INCH = 20 FT. HORIZONTAL 0 2.5 5 10 1 INCH = 5 FT. VERTICAL Ln co C) O N AJ co I1*�- O O O O N DEVELOPMENT ENGINEERING AOM46` � � IL Q yqi 08/07/2025 Fw�jstowell STEWATER UTILITY J 08/05/2025 �0n DATE: V J SOLERRA 09.16.2024 SANITARY SEWER PLAN & PROFILE PAGE: OOK: PAGE: DRAWING NO: 10823, 10815, 10824 145TH PL SE C8 RENTON, WASHINGTON 98059 SHEET: 8 OF: 1 ^ DRS PROJECT NO. 23033