Loading...
HomeMy WebLinkAboutS-4330040 N Q rr rr LLJ J O U) 460 455 0 445 0 435 SE 114 SEC TION 3, TO WNSHIP 23 N, RANGE 5 E, W.M. SOLERRA COR MH4544 48" +I STA. 10+16.99, 49.58' L RIM 436.43 p 00 8 /E IN 429.60 (SW) ° 00 8" JE IN 429.53 (W) _ 8" 1E OUT 429.50 (N) < 54 LF 8" PVC 0 1.32% _ ° C - 25 LF 12" LCPE 0 4.02% (P101) . Ln � (� SSMH 1 48" CB 101 TYPE 1 STA. 10+45.13, 6.67 L 714RU-CURB INLET RIM 438.41 / N 8" JE IN 430.41 (S) ° STA. 10+53.96, 12.88 Ro RIM 438.16 8 /E OUT 430.31 (NE) O CB 14 TYPE 2-48" 00 - 12" /E IN 435.17 (NW) i2" lE OUT 435.17 (E) O 434 STA. 10+41.88, 123.30' L LO (�J i RIM 433.88 !° 2" lE - OUT 4 1 /N 426.00 SW 27 LF 12" LCPE 0 .55% (P201) '} _ _ - - - - - VA 12" lE N _ _ CB 201, TYPE 1 o CB 1 TYPE 2-48" d1p 4-0 =N = _- STA. 10+24.86, 27. 08' R - � / THRU-CURB INLET = RIM 439.96 ` STA. 10+54.63, 11.76' L 436 -� ry I I 21+00 12" JE OUT 436.96 (SE) 22+ jam RIM 438.18 - ® CB 13 II mnP/� r-_- I ?� 12 IE IN 434.18W ----- - () STA. 10+58.99, 90.52' L Z 18 lE /N 430.40 (S) Q RIM 439.54 - 18" EOUT 450.40 (E) �ry 12" lE IN 427.10 (S) Z o - 12" 1E OUT 42Z 10 (NE) o 29 LF 18" LCPE 0 19.70% (P1)�8- v " o y 0 Z p O o � ° d II CENTERLINE OF ROAD f �9S Zoe E 167H ST �co ++ N O II YONS PL NE STA. 10+24.86, 27.08 RLJ RIM 439 96 12" JE OUT 436.96 ( ) 27 LF 12" LCPE 0 6.55X (P201) 0 430 CB 101, TYPE 1 7HRU-CURB INLET STA. 10+53.96, 12.88' R RIM 438.16 12" JE IN 435.17 (NW) 0 12" IE OUT 435.17 (E) 425 25 LF 12" LCP 0 4.02X (P10 CB 14 TYPE 2-48" STA. 10+41.88, 123.30' L CB 1 TYPE 2-48" THRU-CURB INLET - IE 124 12" IN N 426.00 (SW) STA. 10+54.63, 11.76' L p 12 /E OUT 426.00 (N) RIM 438.18 420 12" JE IN (W) 2" PVC 0 2.29% (P1 18" IE /N 430 40 (S) CB 13 E 2-48" 18" JE OUT 43 40 (E) STA. 10+ 8.99, 90.52' L 29 LF 18" LCPE 0 19.70% (P1) RIM 439.50 12" JE IN 427.10 (S) NE 16 -H S T + L YONS PL NE 12" JE OUT 42Z 10 (NE) 00 M 0� QO O m a0 N a0 . �o .� o M o p °j O 'n of � 1� 00 V QO �cj .� N nj o O 6 `O O n ^ ao N o 19+60 Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) 20+00 20+40 03/2025 20+80 21+20 D.R. STRONG 1 CONSUL TING ENGINEERS 2 ENGINEERS PLANNERS SURVEYORS 620 - 7th AVENUE KIRKLAND, WA 98033 O 425827.3063 F 425.827.2423 N0. 21+60 CITY COMMENTS (03.11 CITY COMMENTS (06.2, REVISION 22+00 22+40 22+80 BD 04.02.251 YLP SURVEYED: BD 07.03.25 YLP DESIGNED: BD DRAWN: PHB CHECKED: YLP BY DATE APPR APPROVED: YLP 23+20 SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM 23+60 24+00 460 OC TY OF OR RENTON Planning/Building/Public Works Dept. Ln L0 C) N �J t'J I�- C) O O i 4 N SEWER MANHOLE NOTES. SEWER MANHOLES PER COR STD PLAN 400.1 MANHOLE FRAME AND COVER PER COR STD PLAN 401 UTILI TY CROSSING LEGEND: rSEE TABLE ON SHEET C12 FOR UTILITY CROSSING TABLE AND DESIGN INFORMATION. ONLY SEWER UTILITY PLAN IS REVIEWED ON THIS PLAN SET, ALL OTHER ELEMENTS (E.G. ROAD, GRADING) SHOWN ON THE PLAN SET IS REVIEWED AND APPROVED UNDER SEPARATE PERMIT FROM KING COUNTY. NORTH GRAPHIC SCALE 0 10 20 40 1 INCH = 20 FT. HORIZONTAL 0 2.5 5 10 1 INCH = 5 FT VERTICAL S-433004 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING ASOOO&I IL yqi 08/07/2025 Q WASTEWATER UTILITY + LU jstowell 08/05/2025 J Cl)DATE: V SO LE R RA 09.16.2024 STORM PLAN & PROFILE PAGE: OOK: PAGE: DRAWING NO: 10823, 10815, 10824 145TH PL SE C5 RENTON, WASHINGTON 98059 SHEET: 5 OF:1 ^ DRS PROJECT NO. 23033