HomeMy WebLinkAboutS-433007o, �, M, SE 1/4 SECTION 3, TOWNSHIP 23 N, RANGE 5 E, W.M. SOLE' RRA N' "SIR Q rr rr J O U7 Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) 03/ZQ25 2U UNAINAUL t5M I. REC. NO. 87092311741 UTILITY CROSSING TABLE CROSSING NO. F.G. UTILITY PIPE SIZE (IN) I.E. BOTTOM OF PIPE TOP OF PIPE CLEARANCE (FT) 1 438.43 12" SD 12 434.47 434.42 435.52 2.80 8" SS 8 430.90 430.85 431.62 2 438.38 12" SD 12 434.95 434.90 435.00 0.52 8" WA 8 433.66 433.61 434.38 3 450.63 12" SD 12 447.33 447.28 448.38 4.07 8" SS 8 442.49 442.44 443.21 4 450.62 12" SD 12 447.38 44733 448.43 0.51 8" WA 8 446.10 446.05 446.82 5 454.77 12" SD 12 451.45 451.40 452.50 4.09 8" SS 8 446.59 446.54 447.31 6 454.75 12" SD 12 451.50 451.45 452.55 0.50 8" WA 8 450.23 450.18 450.95 7 459.71 12" SD 12 456.38 455.33 457.43 4.26 8" SS 8 451.35 451.30 452.07 8 459.69 12" SD 12 456.43 456.38 457.48 0.59 8" WA 8 455.07 455.02 455.79 9 461.90 8" WA 8 457.68 457.63 458.40 2.90 8" SS 8 454.02 453.97 454.74 10 462.1 12" SD 12 458.75 458.70 459.80 3.65 8" SS 8 454.33 454.28 455.05 D'S, D.R. STRONG 1 CITY COMMENTS CONSUL TING ENGINEERS 2 CITY COMMENTS ENGINEERS PLANNERS SURVEYORS 620 - 71h AVENUE KIRKLAND, WA 98033 04258273063 F 425.827.2423 N0. 11 REVISION BD 04.02.251 YLP SURVEYED: JGR BD 07.03.25 YLP T==B;D DRAWN: PHB CHECKED: YLP BY DATE APPR APPROVED: YLP SCALE: VERTICAL: NAVD 1988 AS NOTED HORIZONTAL: NAD 1983/1991 ONE INCH DATUM AT FULL SCALE • v IF NOT ONE INCH SCALE ACCORDINGLY N UTILITY CROSSING NOTE: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 811 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT D.R. STRONG CONSULTING ENGINEERS, LLC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. UTILITY CROSSING LEGEND: n SEE TABLE ON THIS SHEET FOR UTILITY CROSSING TABLE AND DESIGN INFORMATION. CROSSING NO TES.- 1. EXISTING WATER ASSUMED DEPTH 3-3.5 FEET. 2. UTILITIES TO BE INSTALLED WITH LESS THAN 1' CLEARANCE, PROVIDE ETHAFOAM PAD. NORTH GRAPHIC SCALE 0 20 40 80 1 INCH - 40 FT. A00%k pj� C TY OF RENTON Planning/Building/Public Works Dept. S-433007 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Ar ` -�' IL yqi 08/07/2025 ' WASTEWATER UTILITY jstowell 08/05/2025 DATE: SO L E R RA 09.16.2024 COMPOSITE UTILITY PLAN FIELDBOOK: PAGE: 10823, 10815, 10824 145TH PL SE C 12 RENTON, WASHINGTON 98059 SHEET:12 OF: 12 DRS PROJECT NO. 23033 N LO co L0 0 0 N u Q rr Ir LU O U)