HomeMy WebLinkAboutT-4330010
CY)
C'M
T
O
rr
Q
w
I
O
U)
w
EX R/W EX
I
I
I 3
EX h
EX R/W
Call 2 Working Days Before You Dig
811
Utilities Underground Location Center
(ID,MT,ND,OR,WA)
o-
EX R/W
2
07-28 2025
I rE m
520 KIRKLAND WAY, SUITE 100, KIRKLAND, WA, 98033
STELLA OH 1 STELLA@TENW.COM 1 206-412-6743
\G]
SE 1/4 SECTION J. TOWNSHIP 23 N, RANGE 5 E, W.M.
SOLERRA
REVISION
de
ILLUMINA IIUN LLGLNU
EXIST. NEW
DESCRIPTION
m
JUNCTION BOX TYPE 1
0
JUNCTION BOX TYPE 2
ROADWAY LUMINAIRE POLE
PEDESTRIAN LUMINAIRE POLE
SURVEYED:
OTHERS
DESIGNED:
ARC
DRAWN:
ARC
CHECKED:
SSO/GMD
APPROVED:
GMD
UTILITY POLE
SERVICE CABINET
CONDUIT/CONDUCTOR
LUMINAIRE POLE NUMBER
CONSTRUCTION NOTE
WIRE NOTE
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
ILLUMINATION CONSTRUCTION NOTES
OCONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 116.1. FURNISH AND INSTALL NEW
NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER PEDESTRIAN
SCALE ILLUMINATION POLE SCHEDULE, SHEET IL-02, AND CITY OF RENTON STANDARD PLANS 116.1,
116.2, 119, 120 & J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE PEDESTRIAN SCALE
ILLUMINATION POLE SCHEDULE, SHEET IL-02, AND CITY OF RENTON STANDARD PLAN 121.
O2 CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.1A. FURNISH AND INSTALL NEW
ARTERIAL STREET DECORATIVE LUMINAIRE POLE, ROADWAY AND PEDESTRIAN SCALE LUMINAIRES, AND
JUNCTION BOX PER ROADWAY SCALE ILLUMINATION POLE SCHEDULE, SHEET IL-02, AND CITY OF RENTON
STANDARD PLANS 117.1, 117.3, 119, 120 & J013. APPLY DECAL NUMBERING WITH COR POLE ID PER
THE ROADWAY SCALE ILLUMINATION POLE SCHEDULE, SHEET IL-02, AND CITY OF RENTON STANDARD
PLAN 121.
O3 EXISTING PEDESTRIAN LUMINAIRE POLE TO REMAIN. PROTECT DURING CONSTRUCTION.
O4 THE POWER SOURCE LOCATION WAS NOT KNOWN AT THE TIME OF PLAN PREPARATION. THE CONTRACTOR
SHALL COORDINATE WITH PSE TO IDENTIFY FOR 1201240 VOLT SINGLE PHASE POWER SOURCE
CONNECTION. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR COMPLETION OF ALL
NECESSARY FORMS/APPLICATIONS ASSOCIATED WITH THE NEW POWER SOURCE. THE CONTRACTOR SHALL
INSTALL CONDUIT AND CONDUCTORS TO THE POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE
FOR SPECIFIC REQUIREMENTS. PSE SHALL MAKE FINAL CONNECTION TO THE POWER SOURCE. THE
CONTRACTOR SHALL ASSUME 500' OF TRENCHING TO CONNECT TO POWER SOURCE FOR BIDDING
PURPOSES.
5 CONSTRUCT SERVICE CABINET FOUNDATION PER CITY OF RENTON STANDARD PLANS 126.1 & 126.2.
FOUNDATION SHALL BE ADJACENT TO AND FLUSH WITH SIDEWALK. FURNISH AND INSTALL SERVICE
CABINET PER CITY OF RENTON STANDARD PLANS 122.1 & 122.2. LOCATION AND ORIENTATION OF
FOUNDATION AND CABINET SHALL BE VERIFIED BY CITY OF RENTON TRANSPORTATION MAINTENANCE
MANAGER PRIOR TO INSTALLATION OF CONDUITS.
OSPLI
BOX. CE NEW ILLUMINATION CONDUCTORS TO EXISTING ILLUMINATION CONDUCTORS IN EXISTING JUNCTION
OEXISTING SERVICE CABINET APPROXIMATELY 320 FEET WEST OF PROJECT IMPROVEMENTS ALONG NE 16TH
STREET TO REMAIN. PROTECT DURING CONSTRUCTION.
O8 CONSTRUCT FOUNDATION PER CITY OF RENTON STANDARD PLAN 117.2. FURNISH AND INSTALL NEW
ARTERIAL STREET DECORATIVE PEDESTRIAN LUMINAIRE POLE, LUMINAIRE, AND JUNCTION BOX PER
PEDESTRIAN SCALE ILLUMINATION POLE SCHEDULE, SHEET IL-02, AND CITY OF RENTON STANDARD PLANS
117.2, 117.3, 119, 120, & J013. APPLY DECAL NUMBERING WITH COR POLE ID PER THE PEDESTRIAN
SCALE ILLUMINATION POLE SCHEDULE, SHEET IL-02, AND CITY OF RENTON STANDARD PLAN 121.
ILLUMINATION WIRING SCHEDULE
RACEWAY
CONDUIT
SIZE
IL#6
POWER
EQUIP.
GRND.
NO.
EX.
NEW
EX.
NEW
EX.
NEW
1
2" SCH80 PVC NEW
2
1
2
2" SCH40 PVC EX
2
1
3
2" SCH80 PVC EX
2
1
4
3" SCH80 PVC NEW
3
* EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR
LARGER THAN THE LARGEST WIRE SIZE IN THE
CONDUIT (MIN. WIRE SIZE SHALL BE #8).
7k
0 10 20 40 60
!I
SCALE IN FEET
C TY OF
RENTON
Plan ning/Building/Public Works Dept.
T-433001
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TRANSPORTATION OPERATION
cbarnes 08/07/2025 %�)"
SOLERRA
DEVELOPMENT ENGINEERING
Uyqi 08/07/2025
ILLUMINATION PLAN
DATE:
07.28.2025
FIELDBOOK:
PAGE:
10823, 10815, 10824 145TH PL SE IL-05
RENTON, WASHINGTON 98059 SHEET:1 OF:5
TENW PROJECT NO. 2024-276
Lr)
C'7
Li)
O
O
N
,
u
C`7
O
O
O
C:)
N
rr
lei
Q
w
J
O
U)