HomeMy WebLinkAboutT-433002O C) T O rr w SE 1/4 SECTION J. TOWNSHIP 23 N, RANGE 5 E, W.M. SOLERIM ROADWAY SCALE ILLUMINATION POLE SCHEDULE LUM. POLE ID STREET STATION * OFFSET * LATITUDE ** LONGITUDE ** POLE MOUNT. ARM VOLTAGE SERVICE/ WATTAGE/ INITIAL LUMINAIRE TYPE - BASE COMMENT **** POLE NO. NUMBER *** HEIGHT HEIGHT LENGTH CIRCUIT TYPE LUMENS DISTRIBUTION 35.5' 6.0' 120W LED 14,634 CYCLONE DOMIA A O SUNSET BLVD NE 41 +25.5 22.5' LT 40.0' 240 ILLUM A CY55P1B-FGC-T3-P80-40K FIXED NEW FOUNDATION AND POLE PER RENTON STANDARD 16.5' 4.0' 34W LED 4, 159 CYCLONE DOMIA PLANS 117.1 AND 117.1A. CY55P 1 B-FGC-T3-P20-40K 35.5' 6.0' 120W LED 14,634 CYCLONE DOMIA B O SUNSET BLVD NE 42+52.0 22.0' LT 40.0' 240 ILLUM A CY55P1B-FGC-T3-P80-40K FIXED NEW FOUNDATION AND POLE PER RENTON STANDARD 16.5' 4.0' 34W LED 4, 159 CYCLONE DOMIA PLANS 117.1 AND 117.1A. CY55P 1 B-FGC-T3-P20-40K * STATIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH CITY INSPECTOR PRIOR TO IMPLEMENTING. ** POLE LATITUDE AND LONGITUDE NUMBERS SHALL BE PROVIDED BY CONTRACTOR FOR INCORPORATION INTO AS -BUILT PLANS. *** POLE ID NUMBERS SHALL BE PROVIDED BY ERIC CUTSHALL (CITY OF RENTON, 425-430-7423) FOR INCORPORATION INTO AS -BUILT PLANS AND INSTALLED BY THE CONTRACTOR IN ACCORDANCE WITH CITY OF RENTON STANDARD PLAN 121. **** REFERENCE STRUCTURAL ANALYSIS LETTER FOR STREET LIGHT POLE FOUNDATION DESIGN, DATED 07-28-2025. PEDESTRIAN SCALE ILLUMINATION POLE SCHEDULE LUM. POLE ID STREET STATION *OFFSET * LATITUDE ** LONGITUDE ** POLE MOUNT. ARM VOLTAGE SERVICE/ WATTAGE/ INITIAL LUMINAIRE TYPE - BASE COMMENT **** POLE NO. NUMBER *** HEIGHT HEIGHT LENGTH CIRCUIT TYPE LUMENS DISTRIBUTION 0NE 16TH ST 20+55.5 24.5' RT 14.0' 15.0' N/A EX EX 44W LED 4,200 CYCLONE PRESTIGE FIXED NEW FOUNDATION AND POLE PER RENTON STANDARD CY18T4-VS3AR-T3-P30-4K PLAN 116.1. O NE 16TH ST 21 +25.5 24.5' RT 14.0' 15.0' N/A EX EX 44W LED 4,200 CYCLONE PRESTIGE FIXED NEW FOUNDATION AND POLE PER RENTON STANDARD CY18T4-VS3AR-T3-P30-4K PLAN 116.1. O NE 16TH ST 21 +90.0 26.5' RT 14.0' 15.0' N/A EX EX 44W LED 4,200 CYCLONE PRESTIGE FIXED NEW FOUNDATION AND POLE PER RENTON STANDARD CY18T4-VS3AR-T3-P30-4K PLAN 116.1. G NE 16TH ST 22+41.5 44.5' RT 14.0' 15.0' N/A EX EX 44W LED 4,200 CYCLONE PRESTIGE FIXED NEW FOUNDATION AND POLE PER RENTON STANDARD CY18T4-VS3AR-T3-P30-4K PLAN 116.1. OS SUNSET BLVD NE 41 +87.0 19.5' LT 20.0' 16.5' 4.0' 240 ILLUM A 34W LED 4,159 CYCLONE DOMIA FIXED NEW FOUNDATION AND POLE PER RENTON STANDARD CY55P 1 B-FGC-T3-P20-40K PLAN 117.2. * STATIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH CITY INSPECTOR PRIOR TO IMPLEMENTING. ** POLE LATITUDE AND LONGITUDE NUMBERS SHALL BE PROVIDED BY CONTRACTOR FOR INCORPORATION INTO AS -BUILT PLANS. *** POLE ID NUMBERS SHALL BE PROVIDED BY ERIC CUTSHALL (CITY OF RENTON, 425-430-7423) FOR INCORPORATION INTO AS -BUILT PLANS AND INSTALLED BY THE CONTRACTOR IN ACCORDANCE WITH CITY OF RENTON STANDARD PLAN 121. **** REFERENCE STRUCTURAL ANALYSIS LETTER FOR STREET LIGHT POLE FOUNDATION DESIGN, DATED 07-28-2025. ILLUMINATION GENERAL NOTES 1. THE LOCATION OF ALL CONDUIT, JUNCTION BOXES, AND CABINETS SHOWN ON THIS PLAN ARE APPROXIMATE ONLY. FINAL LOCATION SHALL BE DETERMINED BY THE CONTRACTOR AND CONFIRMED IN THE FIELD BY THE ENGINEER. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, CITY OF RENTON STANDARDS AND WSDOT STANDARDS AND SPECIFICATIONS, CURRENT EDITION. 3. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY. 4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. 5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE. 7. POLE FOUNDATIONS SHALL NOT BE EXCAVATED AND POURED BEFORE POLE LOCATIONS ARE APPROVED BY THE ENGINEER. 8. ELECTRICAL CONTRACTOR TO CONTACT CITY CONSTRUCTION INSPECTOR FOR INSPECTION OF POLE FOUNDATIONS, BASE BOLTS, AND CABINET FOUNDATION. 9. CONTRACTOR TO CONTACT CITY ELECTRICAL INSPECTOR FOR UNDERGROUND/ROUGH-IN INSPECTION. 10. CONTRACTOR TO CONTACT TRANSPORTATION MAINTENANCE MANAGER, ERIC CUTSHALL 425-430-7423, FOR STREET LIGHTING COMPLIANCE TO STANDARDS INSPECTION PRIOR TO ENERGIZING. 11. FOLLOWING THE TRANSPORTATION MAINTENANCE INSPECTION, THE CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR SERVICE INSPECTION. 12. FOLLOWING THE SERVICE INSPECTION FROM CITY ELECTRICAL INSPECTOR, ELECTRICAL CONTRACTOR SHALL SUBMIT APPLICATION TO PSE TO ENERGIZE THE STREET LIGHTING. 13. ELECTRICAL CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR FINAL INSPECTION AFTER STREET LIGHTING HAS BEEN ENERGIZED. 14. CONTRACTOR SHALL POTHOLE ALL POLE LOCATIONS TO CONFIRM THAT THERE ARE NO UNDERGROUND CONFLICTS. IF A CONFLICT IS DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO FOUNDATION INSTALLATION. 15. THE CONTRACTOR SHALL CONFIRM THAT THE APPROPRIATE MINIMUM CIRCUMFERENTIAL CLEARANCE IS PROVIDED BETWEEN LUMINAIRE POLES AND OVERHEAD POWER LINES. IF A CONFLICT IS DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO FOUNDATION INSTALLATION. 16. CITY OF RENTON REQUIRES STREET LIGHT POLE FOUNDATION DEPTH TO BE DETERMINED PER STRUCTURAL ANALYSIS. A STRUCTURAL ENGINEER AND/OR GEOTECHNICAL ENGINEER MAY BE REQUIRED TO PROVIDE THIS INFORMATION. Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) 07-28 2025 ILLUMINATION WIRING DIAGRAM EX SERVICE CABINET AT NE 16TH ST EX ILLUM B NEW SERVICE CABINET AT SUNSET BLVD NE ILLUM B ILLUM C SPAR NE 16TH ST SUNSET BLVD NE EX SERVICE BREAKER SCHEDULE AT NE 16TH ST CIRCUIT BREAKER CONTACTOR EX MAIN 2P-100 AMP --- EX ILLUM A 2P-20 AMP 30 AMP EX ILLUM B 2P-20 AMP 30 AMP NEW SERVICE BREAKER SCHEDULE AT SUNSET BLVD NE CIRCUIT BREAKER CONTACTOR MAIN 2P-200 AMP --- ILLUM A 2P-20 AMP 30 AMP ILLUM B 2P-20 AMP 30 AMP ILLUM C SPARE 2P-20 AMP 30 AMP Q O N NOT TO SCALE ` SURVEYED: SCALE: OTHERS VERTICAL: NAVD 1988 AS NOTED HORIZONTAL: NAD 1983/1991 DESIGNED: ARC ` DRAWN: A ARC ONE INCH DATUM CHECKED: AT FULL SCALE 520 KIRKLAND WAY, SUITE 100, KIRKLAND, WA, 98033 SSO�GMD IF NOT ONE INCH STELLA OH 1 STELLA@TENW.COM 1 206-412-6743 NO. REVISION BY DATE APPR APPROVED: GMD SCALE ACCORDINGLY SHUTLER CONSULTING ENGINEERS, INC. July 28, 2025 Stella Oh TEN W 520 Kirkland Way, Suite 100 Kirkland, WA 98033 Re: Solerra Renton, WA Stella, 12503 Bel-Rcd Road, Suite 100, Bellevue, WA 98005' (425) 450-4077 Job #25-01.43 I have reviewed the information provided for the concrete bases for the new light poles that will be installed for this project, as well as the plan review comments provided by ReidMiddleton. Light Poles A and B will be 40 feet tall with two lights. The base will be 36" diameter and 8'-0" deep. It shall be reinforced with 8 - #8 vertical bars and #4 hoops at 12" o.c. The concrete strength shall be 3500 psi minimum. The anchors are shown as four 1-1/4" diameter GR. 55 and shall be embedded a minimum of 36" into the foundation. bight Poles 1, 2, 3, and 4 will be a 14 foot tall pole with a 32" tall light at the top. The base will be 24" diameter and 4'-0" deep. They shall be reinforced with 8 - #5 vertical bars and #4 hoops at 12" o.c. The concrete strength shall be 3500 psi minimum. The anchors are shown as four I" diameter GR. 55 and shall be embedded a minimum of 24" into the foundation. Light Pole 5 will be 20 feet tall with a single light. The base will be 30" diameter and 5'-0" deep. It shall be reinforced with 8 - #6 vertical bars and #4 hoops at 12" o.c. The concrete strength shall be be 3500 psi minimum. The anchors are shown as four V diameter GR. 55 and shall be embedded a minimum of 24" into the foundation. I used the following soil values from IBC section 1806 for the design of the concrete bases -1500 psf bearing and 100 pcf passive. A copy of my revised calculations is attached. Give me a call if you have any questions or need additional information. Sincerel , J hA Headland, PE SE Pt' cipal c 1�Ega wasy�� o� aw h 31�757 :r T-433002 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TRANSPORTATION OPERATION I DEVELOPMENT ENGINEERING ` + cbUl arnes 08/07/2025 yqi 08/07/2025 ® DATE: C TY OF SOLERRA 07.28.2025 - FIELDBOOK: RENTON ILLUMINATION PLAN DETAILS PAGE: DRAWING N0: N LO co O N , u O O O O N rr '11 TENW PROJECT NO. 2024-276