Loading...
HomeMy WebLinkAboutT-4330030 M M SE 1/4 SECTION J. TOWNSHIP 23 N, RANGE 5 E, W.M. SOLERRA T I 0 rr rr LL LU J /0//� VJ w DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1 561 D7F PAINT SPECIFICATIONS: ALL ALUMINUM LUMINAIRE AND POLE RELATED PARTS SHALL BE FACTORY PRIMED AND POWDER COATED. FINISH COLOR: RAL 9005TX "JET BLACK", OR APPROVED EQUAL WITH PAINT CHIP 18-1/4" PRESTIGE SERIES (CY17T4) LED POST -TOP LUMINAIRE (WATTAGE PER PLANS, 4,000K CCT, 120-277V UNIVERSAL DRIVER, WITH VS3AR a ,k, RIBBED ACRYLIC LENS) BY CYCLONE n (� (OR APPROVED EQUAL). DRIVER I I SHALL BE INTEGRAL TO THE FIXTURE. 1" THICK BASE PLATE (4) 1 1/4" DIA, x 1 5/8" LG. SLOTTED HOLES R = 2° (TYP) 41t` O 0 BASE PLATE DETAIL 24" 8 - g5 BARS, 2" CONDUIT UNLES EVENLY SPACED STATED OTHERWISE ON PLANS CENTER CONDUIT IN FOUNDATION BOLT CIRCLE (DIA PER ANCHOR BOLT BASE PLATE DETAIL, THIS SHEET) #4 HOOPS 0 12" FOUNDATION SECTION 2" CONDUIT UNLESS GROUND POLE TO STATED OTHERWISE ON L FOUNDATION PER PLANS �w STDPLAN 119 MIN CONDUIT COVER FOR STREET LIGHT STANDARD DECAL EXTEND CONDUIT 6" MIN BEYOND NUMBERING DETAIL, FOUNDATION OR CONTROLLED a z REFER TO CITY OF DENSITY BACKFILL a RENTON STD PLAN 121 U w #4 HOOPS 0 12" m w0 14'-0" FLUTED SHAPE, 5" DIAMETER, g - ()5 BARS, STRAIGHT ALUMINUM POLE EVENLY SPACED w vasi (PD15-14-BD46-RAL9005TX-TN43) 2 1/2" CUR BY CYCLONE (OR APPROVED EQUAL) a W c U Z a o INSTALL GROUT AND PROVIDE 'i 1/2" DIA DRAIN TUBE THROUGH GROUT. LOCATE DRAIN TUBE WITH SURFACE DOWNWARD. SLOPE DIRECTION FOUNDATION DETAIL 1 1/8" DIA HOLE "T�.r•. (TYP) •%.. �, /--� 3/8" THICK STEEL PLATE BOLT CIRCLE (DIA PER BASE PLATE 2"x5" HANDHOLE POLE BASE DETAIL DETAIL, THIS SHEET) ANCHOR BOLT TEMPLATE DETAIL DECORATIVE ALUMINUM CLAMSHELL BASE COVER BD46 BY CYCLONE (OR APPROVED EQUAL) TOP OF FOUNDATION ANCHOR BOLT, 4 TOTAL, 1" DIA, STEEL n SEE POLE BASE F1554 OR GRADE 55 (TYP) DETAIL, THIS o SHEET 1° HEX NUTS, STEEL (6 REQ'D PER 16" DIAMETER ANCHOR BOLT), AND BASE COVER FLAT WASHERS, STEEL (6 REQ'D PER `r:Fri%•".''-`�"'1' - ., : •ri::Li='.;. ;X:•'�J ANCHOR BOLT) ANCHOR BOLT ASSEMBLY DETAIL FOR FOUNDATION DETAILS, SEE THIS SHEET. FOUNDATION NOTES: CONCRETE PAD OR EDGE OF FOUNDATION SHALL BE LOCATED 1. SONATUBE SHALL NOT BE ALLOWED SIDEWALK PER STD PLAN AT LEAST 5' FROM CITY UTIUTIES UNLESS 2. ALL FOUNDATION HARDWARE SHALL BE HOT -DIPPED GALVANIZED IN 120 OTHERWISE APPROVED BY THE CITY ACCORDANCE WITH THE LATEST WSDOT STANDARD SPECIFICATION SECTION POLE ELEVATION 9-29.6(5) FOUNDATION HARDWARE FOUNDATION DETAILS NEIGHBORHOOD STREET STD. PLAN - 116.1 PUBLIC WORKS PEDESTRIAN LUMINAIRE APPROVED: DEPARTMENT FIXTURE AND POLE DETAILS r 7/27/2022 rtinPastucha DATE DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F DIRECTION GENERAL NOTES: rAINi arVJHUAUUNa: ALL LUMINAIRE, POLE, CAST ALUMINUM STREET OF STREET OF 1. DOWNTOWN DECORATIVE PEDESTRIAN LUMINAIRES CURB AND-7h� tt�tt TRAFFIC CURB AND77�� }�} TRAFFIC SHALL BE EQUIPPED WITH ALL EQUIPMENT BASE PARTS, AND ANY ADDITIONAL SIDEWAL SIDEWAL SHOWN ON THIS SHEET EQUIPMENT MOUNTED ON THE POLE 2. ARTERIAL DECORATIVE PEDESTRIAN LUMINAIRES SHALL BE FACTORY PRIMED AND POWDER 210 me 90 SHALL NOT COME EQUIPPED WITH BANNERS AND COATED TO MATCH FINISH COLOR. FLOWER BASKET ARMS/BASKETS �. ��. DOWNTOWN LOCATION ARTERIAL LOCATION 3. ORIENTATION OF EQUIPMENT FOR DOWNTOWN ALL BANDING AND ALL OTHER MOUNTING LOCATIONS AND ARTERIAL LOCATIONS SHALL BE HARDWARE SHALL MATCH FINISH NI H COLOR. ORIENTATION NOTES - DOWNTOWN LOCATIONS ORIENTATION NOTES - ARTERIAL LOCATIONS PER ORIENTATION LOCATION DETAIL, THIS SHEET DECORATIVE PEDESTRIAN LUMINAIRES MOUNTED • DECORATIVE PEDESTRIAN LUMINAIRES FINISH COLOR: RAL 9005TX "JET BLACK", AT 0', UNLESS OTHERWISE NOTED ON PLANS MOUNTED AT 180', UNLESS OTHERWISE OR APPROVED EQUAL WITH PAINT CHIP. HANDHOLES MOUNTED AT 180' NOTED ON PLANS RECEPTACLE MOUNTED AT 180' HANDHOLES MOUNTED AT 0' DECORATIVE LUMINAIRE POLE NOTES CARFLEX CONDUIT AND IRRIGATION HOLE RECEPTACLE MOUNTED AT 0' 2'6° LOCATED AT 0' • ECONDUIT AND IRRIGATION HOLE g - L,5 BARS, O ROUND TUBULAR SECTION PLANT LOCATED SUPPORT BRACKETS MOUNTED AT 90' LOCATEDD AT 180' EVENLY SPACED (NO TAPER) & 270. (UNLESS OTHERWISE NOTED ON PLANS) ONE 2" CONDUIT, UNLESS • BANNER MOUNTED AT 180' STATED OTHERWISE ON THE CENTER ORIENTATION LOCATION DETAIL PLANS. STUBOUT 1' FROM CONDUIT DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, EDGE OF CONCRETE a IN TYPE 3 IES DISTRIBUTION 4000K CCT 120- 4" ALUMINUM POLE TOP CAP FOUNDATION AND CONNECT FOUNDATION UNIVERSAL DRIVER (750mA OR LOWER), WITH FLAT (3) SET SCREWS AT 120' APART TO CITY JUNCTION BOX PER (3 GLASS LENS) BY CYCLONE (OR APPROVED EQUAL) STD PLAN 119 #4 HOOPS 0 12" DRIVER SHALL BE INTEGRAL TO THE FIXTURE. FOR 0 ANCHOR BOLT D MOUNTING ARM ETAILS SEE STD PLAN 117.3. HIRING N PER STD PLAN 119. FOUNDATION SECTION , oa -1 W GROUND POLE O CONDUIT, SEE FOUNDATION TO FOUNDATION a "i 4" O.D. SECTION, THIS SHEET PER STD PLAN TOP OF CONCRETE 119 = PAD/SIDEWALK DOWNTOWN LOCATIONS ONLY. (2) DECORATIVE 18 BANNER BRACKETS WITH PRESSURE RELEASE SPRINGS WITH PROTECTIVE RUBBER COATING DOWNTOWN LOCATIONS ONLY. 1/2" DIA. HOLES FOR BANNER. SECURE TOP = _ _ _ _ _ - BANNER BRACKET WITH THROUGH BOLTS AND o SHIM TO LEVEL PER MANUFACTURER'S INST a DOWNTOWN LOCATIONS - ONLY. 2' x 4' z STREET LIGHT STANDARD DECAL DECORATIVE BANNER s` NUMBERING PER STD PLAN 121 EXTERNAL FESTOON CASTING WITH DOWNTOWN LOCATIONS R I2 LOCKABLE DIE CAST NEMA 3R ONLY. 2' DECORATIVE11 '^ m < LOCKING, PRINTABLE, WEATHERPROOF, BANNER ARM WITH FINIAL w a Y IN -USE COVER, MODEL WP101OMC BY p4 HOOPS ®12" z L-1 a INTERMATIC (OR APPROVED EQUAL) 3 MOUNTED TO GFCI RECEPTACLE. PAINT 0 8 -5 BARS, EVENLY o i TO MATCH POLE i SPACED z N 3" x 5" REINFORCED ALUMINUM DRIP 2-1/2" CUR F ACCESS HANDHOLE OPENING AND a DOWNTOWN LOCATIONS ONLY. FLUSH FITTING ALUMINUM DOOR 'NTH a z o o SECURE BOTTOM BANNER GASKET LOCATED AT 180' J o a o BRACKET WITH 3 ADJUSTABLE STAINLESS DOWNTOWN LOCATIONS ONLY. o STEEL BANDS AND SHIM TO DECORATIVE FLOWER BASKET AND LEVEL PER MANUFACTURER'S ARMS PER STD PLAN 117.4 I INSTRUCTIONS o _ 1" DIA. IRRIGATION TAPERED POLE SHAFT FABRICATED FROM 6063-T4 FOUNDATION DETAIL TUBING HOLE ALUMINUM TUBE (POLE " o - m ASSEMBLY HEAT TREATED TO 1n 3/8° STEEL PLATE T6 CONDITION AFTER WELDING) 1-1/8" DIA HOLE (TY ) / ASTM 356, SPLIT CAST i ALUMINUM BASE, 2'-0" 6" O.D. x .250" WALL 3" BOLT CIRCLE PER STD co TALL, WITH 4" x 8" TOP OF BASE ACCEPTING 6" PLAN 117.4 REMOVABLE ACCESS DOOR. STRAIGHT ROUND POLE z o SEE STD PLAN 117.4 FOR SECTION. INSTALL RUBBER ANCHOR BOLT TEMPLATE DETAIL ADDITIONAL DETAILS GASKET AT TOP OF BASE o .� 3" x 5" REINFORCED ALUMINUM � 1.5' MIN. HANDHOLE OPENING ON POLE WITH TOP OF FOUNDATION z TO 3.5' MAX FROM 3/6"-16 HOLE FOR A GROUND FACE OF CURB TO CONNECTOR AND FLUSH FITTING ANCHOR BOLT TEMPLATE, TOTAL, ALUMINUM DOOR WITH GASKET SEE ANCHOR BOLT TEMPLATE FACE OF BASE DETAIL, THIS SHEET (TYP) FABRICATED ALUMINUM BASE PLATE ASSEMBLY ANCHOR BOLT, 4 TOTAL, 1" DIA, PER SID PLAN 117.4 STEEL F1554 OR GRADE 55 (TYP) "i TOP OF SIDEWALK OR �i 1" HEX NUTS (6 REO'D PER ANCHOR CONCRETE PAD BOLT), AND FLAT WASHERS (6 REQ'D PER ANCHOR BOLT) FACE OF CURB • - - <: ANCHOR BOLT ASSEMBLY DETAIL CONCRETE PAD OR SIDEWALK FOUNDATION NOTES PER STD PLAN 120 1. SONOTUBES SHALL NOT BE ALLOWED IF SURFACE IS NOT LEVEL, INSTALL FOUNDATION, SEE THIS SHEET. EDGE OF 2. ALL FOUNDATION HARDWARE SHALL BE HOT -DIPPED GALVANIZED IN GROUT AT BASE OF POLE AND BASE FOUNDATION SHALL BE LOCATED AT ACCORDANCE WITH THE LATEST WSDOT STANDARD SPECIFICATION COVER, PROVIDE 1/2" DIA DRAIN TUBE SECTION 9-29.6(5) FOUNDATION HARDWARE LEAST 5' FROM CITY UTILITIES UNLESS THROUGH GROUT POLE ELEVATION OTHERWISE APPROVED BY THE CITY FOUNDATION DETAILS Y ARTERIAL S DOWNTOWN STREET - STD. PLAN 117.2 � PUBLIC WORKS ® DECORATIVE PEDESTRIAN APPROVED: DEPARTMENT LUMINAIRE POLE DETAILS 7/27/2022 Martin Pastucha DATE Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) y� sy 00 %P._ Ss�CNAL �a 07-28 2025 DocuSign Envelope ID: FFA9ADCA-DO50-445F-B750-15F9271FC791 LUMINAIRE COMPONENTS HEAD MODULE OPTIC MODULE TWIST -LOCK OPENING SYSTEM DRIVER MODULE 0❑ HEAD MODULE: ROUND SHAPE. A HEAVY SPUN ALUMINUM HOOD, WITH AN ALUMINUM DECORATIVE CUPOLA AND CAST ALUMINUM FINIAL, TOPS AN INJECTION -MOLDED CLEAR ACRYLIC RIBBED (VS3AR) VESSEL. UV POLYMER RESISTANT. THE VESSEL IS MECHANICALLY ASSEMBLED WITH AN ALUMINUM DIE-CAST RING ON THE LOCKING SYSTEM. OPENING SYSTEM: A QUARTER -TURN LOCKING MECHANISM WITH CONSISTENT PRESSURE POINTS. ALLOWS A TOOL -FREE ACCESS INSIDE THE LUMINAIRE, TO THE LEDS AND DRIVER. MADE WITH CAST ALUMINUM PARTS AND SEALED WITH A GASKET COMPRESSION SYSTEM. THE LUMINIARE OFFERS AN IP66 WEATHERPROOF PROTECTION. CONE MODULE: A SPUN ALUMINUM BALLAST HOUSING WITH STAINLESS STEEL CAPTIVE RETAINING LATCHES. CERTIFICATION, MAINTENANCE AND LUMINAIRE CODIFICATION STICKERS ARE LOCATED ON THE CONE. FITTER MODULE: CAST ALUMINUM ALLOY 356 FITTER COMPLETE WITH FOUR (4) ARMS AND ONE DECORATIVE RING. SECURED ON POLE WITH 3 SET SCREWS 5/16-18 UNC. SLIP -FITS ON A 4" OD BY 3" LONG TENON. OPTICAUELECTRICAL COMPONENTS LED BOARD: WATTAGE PER PLANS. 4000K (WHITE), SUPER HIGH FLUX OUTPUT AND HIGH LUMINANCE, DESIGN FOR HIGH CURRENT OPERATION. FAST TOOL -FREE MAINTENANCE THAT ALLOWS INDIVIDUAL REPLACEMENT OF A DEFECTIVE LED BY PULLING OUT THE PROPER UNIT. OPTIC: IES TYPE II (2L), III (3L), V (5L). THE OPTIC'S REFLECTOR IS MADE OF PRE -ANODIZED ALUMINUM REFLECTING SHEETS (86% MIN. REFLECTION), SEGMENTED IN MULTIPLE FACETS AND VENTILATED BY MULTIPLE PERFORATION AND BY HEAT SINK RADIATOR TO KEEP THE LAMPS TEMPERATURE DOWN AND INCREASE THEIR LONGEVITY. THE ORIENTATION OF EACH FACET HAS BEEN METICULOUSLY CALCULATED TO OPTIMIZE THE LIGHT DISTRIBUTION FOR EACH APPLICATION. DRIVER MODULE: WITH DRIVER, PRIMARY VOLTAGE 120 TO 277 VOLTS. 60 HZ. ASSEMBLED ON A TOOL -FREE REMOVABLE STAINLESS STEEL TRAY WITH QUICK -DISCONNECT CONNECTORS. HIGH POWER FACTOR OF 90%. MINIMUM STARTING TEMPERATURE -40'F. GENERALIOPTIONS WIRING/HARDWARE: TYPE TEW 14-7, 12" MINIMUM EXCEEDING FROM LUMINAIRE. ALL ELECTRICAL CONNECTIONS BETWEEN MODULES ARE MADE WITH QUICK -DISCONNECT CONNECTORS. ALL EXPOSED HARDWARE IS STAINLESS STEEL. EPDM AND/OR SILICON GASKETING ARE APPLIED. WIRE NUTS SHALL NOT BE ALLOWED. STRAIN RELIEF SHALL BE REQUIRED AND SHALL BE PER MANUFACTURER'S RECOMMENDATIONS. FITTER MODULE LUMINAIRE WIRING SHALL BE INSTALLED PER STD PLAN 119. COLOR: RAL9005TX (JET BLACK) FINISH: TEXTURED. H OF THE POLE FOUNDATION IS TO APPLICATION OF A POLYESTER POWDER COAT OF PAINT. (5 MILS/127 MICRONS). THE D P BE CONFIRMED BY STRUCTURE ANALYSIS, THE FINISH MEETS THE ASTM G7, B117 AND D1654 REQUIREMENTS RELATIVE TO WHICH IE CURRENTLY UNDER REVIEW OF SALT SPRAY AND HUDMIDITY RESISTANCE. REID t EIGHBORHOOD STREET STD. PLAN - 116.2 PUBLIC WORKS PEDESTRIAN LUMINAIRE FIXTURE APPROVED: �a DEPARTMENT DETAILS � o 4/4/2024 1 1" DATE DocuSign Envelope ID: FFA9ADCA-D050-445F-B750-15F9271FC791 06 5/8" ROADWAY SCALE POLE t- 04" PEDESTRIAN SCALE CL DIRECT ACCESS (LUMINAIRE ARM = TO THE SCREWS POLE 10'-0" 0L (LUMINAIRE ARM LENGTH) n 2" TANGENT BRACKET 45' R 38° 4LINITH,z � _ THISEADS SIDE 6" WIREWAY TOP VIEW 4" OD HOLE 3W X 5H 6061-T6 4"W X CH - 6061-T6 0.188" 0.188" RECTANGULAR 2 RECTANGULAR ALUMINUM TUBE TERMINAL ALUMINUM TUBE w BLOCK = 12'-0" CONNECTOR (LUMINAIRE ARM LENGTH) PO E 60' R 46" 1 1/2" 4,-0" MAX OPENING (LUMINAIRE ARM LENGTH) 1-11 FOR WIREWAY 2" TANGENTI3 5" 6" 7.5' R 4"0 HOLE 4"W X 6"H - 5061-T6 0.188" TOP LUMINAIRE HOUSING 5 RECTANGULAR ALUMINUM TUBE 3.5"� HOLE ALUMINUM FIN WELDED TO YW X 5"H 6061-T6 0.188" ARM AND POLE CLAMP O -- RECTANGULAR ALUMINUM TUBE ------------------------------------------------------------------------ - ---- - -- = WIREWAY SHALL BE SCH40 ALUMINUM PIPE WITH MINIMUM 1" z ID, AND MAXIMUM 1 1/2" OD. TYPICAL FOR ALL ARMS I 6'-0" (LUMINAIRE ARM LENGTH) ROUND CAP o = PIGTAIL FROM FIXTURE TO 16' R 22" ALUMINUM SHROUD = TERMINAL BLOCK SHALL BE (BY MANUFACTURER) PROVIDED BY 6„ MANUFACTURER. MANUFACTURER FOR TERMINAL BLOCK DETAIL, 4"0 HOLE SHALL WELD SHROUD SEE THIS SHEET ALL THE WAY /4"W AROUND X CH - 6061-T6 0.188"-------- ------ STRAIN RELIEF, = RECTANGULAR ALUMINUM TUBE SEE NOTE 7 cc LUMINAIRE ARM Z CLAMP -ON TO LUMINAIRE n (LUMINAIRE ARM LENGTH) LUMINAIRE c� I CONDUCTORS, o 30' R 30" SEE STD ¢ " DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, z } PLAN 119 TYPE 3 IES DISTRIBUTION, 4000K CCT, 120-277V 6" UNIVERSAL DRIVER (750mA OR LOWER), WITH FLAT GLASS LENS) BY CYCLONE (OR APPROVED EQUAL) 4"0 HOLE DRIVER SHALL BE INTEGRAL TO THE FIXTURE F THE POLE FOUN A4TWIPIS 5" THE DEP H BE CONF R 0 1 T6 0.188", 3 PRONG METAL ED BY STRUCTURE ARit�§]arl�,6'tt,6,ALU INUM TUBE BIRD SPIKES WHICH IS CURRENTLY UNDER REVIEW OF 4.75"f�f REID MID ETMNS: UV PROTECTED MINAIRE ARM LENGTH SHALL BE 10' OR LESS POLYCARBONATE BASE 2. STD PLAN 117.1/117.1A PEDESTRIAN SCALE LUMINAIRE ARM LENGTH SHALL BE 4' OR LESS 3. STD PLAN 117.2 LUMINAIRE ARM LENGTH SHALL BE 4' OR LESS FOR ARTERIAL LOCATIONS, AND 2' FOR DOWNTOWN LOCATIONS 4. LUMINAIRE ARM LENGTH SHALL BE 12' OR LESS FOR TYPE III TRAFFIC SIGNAL POLES 5. POLE AND BRACKET CABLE SHALL BE 10 AWG WITH O.D. LESS THAN 0.5 INCHES 6. BIRD SPIKES SHALL BE REQUIRED ON LUMINAIRE ARM, LUMINAIRE FIXTURE CAP, AND LUMINAIRE/SIGNAL POLE CAP (IF APPLICABLE), UNLESS OTHERWISE APPROVED BY THE CITY. PAINT TO MATCH LUMINAIRE POLE COLOR 7. ALL LUMINAIRE FIXTURES SHALL INCLUDE STRAIN RELIEF PER STD PLAN 118 �Y LUMINAIRE AND MOUNTING STD. PLAN- 117.3 PUBLIC WORKS BRACKET DETAIL APPROVED: DEPARTMENT �.0 4/4/2024 1 4 N DATE 520 KIRKLAND WAY, SUITE 100, KIRKLAND, WA, 98033 STELLA OH I STELLA@TENW.COM 1 206-412-6743 N0. REVISION DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F ROUND POLE CAP ALUMINIUM SHROUD (BY MANUFACTURER) DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, TYPE 3 IES LUMINAIRE ARM LENGTH DISTRIBUTION, 4000K OCT, 120-277V UNIVERSAL DRIVER (75OmA OR PER PLANS, 10' MAX LOWER), WITH FLAT GLASS LENS) BY CYCLONE (OR APPROVED EQUAL) •i O PAINT SPECIFICATIONS: ALL LUMINAIRE, POLE, CAST ALUMINUM BASE PARTS, AND ANY ADDITIONAL EQUIPMENT MOUNTED ON THE POLE SHALL BE FACTORY PRIMED AND POWDER COATED TO MATCH FINISH COLOR. ALL BANDING AND ALL OTHER MOUNTING HARDWARE SHALL MATCH FINISH COLOR. FINISH COLOR: RAL 9005TX "JET BLACK", OR APPROVED EQUAL WITH PAINT CHIP. DECORATIVE LUMINAIRE POLE NOTES .I (1 ROUND TUBULAR SECTION (NO TAPER) DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, TYPE 3 IES DISTRIBUTION, 4000K CCT, 120-277V w UNIVERSAL DRIVER (750mA OR LOWER), WITH FLAT GLASS LENS) BY a CYCLONE (OR APPROVED EQUAL) DRIVER SHALL BE INTEGRAL TO THE FIXTURE. FOR MOUNTING ARM DETAILS SEE STD PLAN 117.3. WIRING PER 4' 0" o STD PLAN 119. LUMINAIRE ARM i i® 18" FOR STREET LIGHT STANDARD DECAL NUMBERING DETAIL, REFER TO CITY OF RENTON STD PLAN 121 Y POLE SHAFT FABRICATED FROM 6063-T4 2 w ALUMINUM, HEAT TREATED TO T6 CONDITION AFTER WELDING. 10" O.D. x 0.250" WALL AT BOTTOM OF POLE SHAFT, 9.375" O.D. AT 27° F o UP FROM BUTT OF POLE. TAPERED BETWEEN z g LUMINAIRE CONNECTIONS � o DRIVER SHALL BE INTEGRAL TO THE FIXTURE. FOR MOUNTING ARM L DETAILS SEE STD PLAN 117.3. WIRING PER STD PLAN 119. (6)HOLES WITH 1 1/4' D A SLOTTEDNG "HX 27 $" HEAD CONNECTING BOLTS AND NUTS A36 STEEL, /-1 S THICK p' BASE PLATE 15"0 BOLT CIRCLE POLE BASE PLATE DETAIL FOUNDATION SHALL SUPPORT POLE SHOWN IN STANDARD PLAN 117.1A FOUNDATION, AND ANCHOR BOLT DETAILS PER STANDARD PLAN 90' � 180' o 0' v= a 217 s1-1 o • DECORATIVE ROADWAY LUMINAIRES IR ARE MOUNTED AT 0' z o • DECORATIVE PEDESTRIAN LUMINAIRES ARE MOUNTED AT 180' • HANDHOLES ARE MOUNTED AT 180' ', [Z ORIENTATION LOCATION i 9V OCTAGONAL SPLIT T0? I•D• CAST IRON BASE WITH REMOVABLE DECORATIVE BASE COVER PER ACCESS DOOR DETAIL, THIS SHEET i 4" X 8" REINFORCED ALUMINUM HANDHOLE OPENING WITH 18 HOLE FORA GROUND CONNECTOROR AND FLUSH FITTING CAST ALUMINUM ANCHOR BASE, ALUMINUM DOOR W/ GASKET INSTALL ANCHOR BOLT COVERS (PROVIDED BY POLE MANUFACTURER) 6" HIGH SIDEWALK 21" `i OR PLANTER STRIP DECORATIVE BASE COVER ROADWAY CONCRETE PAD/SIDEWALK PER STD PLAN 120 IF SURFACE IS NOT LEVEL, INSTALL GROUT AT BASE OF POLE AND FOUNDATION PER STRUCTURAL ANALYST BASE COVER, PROVIDE 1/2" DIA DRAIN TUBE THROUGH GROUT THE DEPTH OF THE POLE FOUNDATION I POLE ELEVATION BE CONFIRMED BY STRUCTURE ANALYSI WHICH IS CURRENTLY UNDER REVIEW OF REID MIDDLETON ARTERIAL STREET STD. PLAN - 117.1 ®� PUBLIC WORKS DECORATIVE LUMINAIRE POLE APPROVED: DEPARTMENT DETAILS 7/27/2022 1 A Martin Pastucha �� DATE DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F aCKET CABLE, #10 AWG. SPLICES BETWEEN FUSE HOLDER AND LUMINAIRE FIXTURE SHALL NOT BE ALLOWED FUSE KITS QUICK DISCONNECT 3 AMP IN LINE FUSE KITS S.E.C. OR EQUAL, ONE PER CURRENT CARRYING REFER TO WSDOT LOCKING CONDUCTOR. APPLIES TO LUMINAIRE LID STANDARD DUTY AND RECEPTACLE WIRING I JUNCTION BOX TYPES 1 & 2 STANDARD PLAN J-40.10 SPLICE KITS CLEAR EPDXY SPLICE KITS ON ALL THRU WIRE RUNS - CONCRETE PAD OR SIDEWALK PER STD PLAN 120 24"(MIN) COVER #8 BARE COPPER GROUND WIRE GROUND LUG LUMINAIRE TO RECEPTACLE -120VAC RECEPTACLE WIRING, IF APPLICABLE. WIRING SIZE PER CONTRACT TO LUMINAIRE -GREEN INSULATED WIRE, SIZED TO MATCH THE LARGEST CURRENT CARRYING CONDUCTOR. TERMINATE AT LUMINAIRE ,GROUND LUG \��\\ \�\ \� \ , II - GROUND II II CLAMP II II I I 1 - EQUIPMENT GROUND-` PVC CONDUIT II II WIRE W/GREEN INSULATION REBARO CONNEDCTIOTO FROM SERVICE CABINET, REBAR USING AN ACORN SEE NOTE 2, THIS SHEET 5/8"x8' COPPER CLAD CLAMP 2 -LIGHTING SYSTEM GROUND ROD CONCRETE FOUNDATION WIRES TO CONTACTOR (SIZED AS REQ'D.) 2 - 120VAC RECEPTACLE SYSTEM WIRES TO SERVICE CABINET, IF APPLICABLE (SIZED AS REQ'D.) NOTES: 1. THIS DETAIL DEPICTS THE BASIC LUMINAIRE ELECTRICAL WIRING SYSTEM. ADDITIONAL ELECTRICAL EQUIPMENT MAY VARY. 2. MINIMUM GROUND WIRE SIZE SHALL BE #8, AS SHOWN ABOVE. IF CURRENT CARRYING CONDUCTORS ARE LARGER THAN #8, THE MINIMUM GROUND WIRE SIZE SHALL MATCH THE LARGEST WIRE SIZE OF THE CURRENT CARRYING CONDUCTORS. 3. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE. 4. IF THE FIXTURE MANUFACTURER HAS MADE PROVISIONS FOR THE ATTACHMENT OF A GROUND WIRE, A GREEN INSULATED WIRE, SIZED TO MATCH THE LARGEST CURRENT CARRYING CONDUCTORS, SHALL BE RUN FROM THE FIXTURE TO THE POLE GROUND LUG. 5. ALL CONDUIT SHALL BE PVC SCHEDULE 80. LIFER GROUND, NON -INSULATED #4 AWG STRANDED COPPER, PROVIDE 3' MIN. SLACK. ROUTE FROM GROUNDING Y LUMINAIRE ELECTRICAL STD. PLAN - 119 PUBLIC WORKS WIRING SYSTEM • APPROVED: DEPARTMENT 7/27/2022 1 5 'p Martin Pastucha DATE SURVEYED: OTHERS DESIGNED: ARC DRAWN: ARC CHECKED: SSO/GMD BY DATE AP P R APPROVED: GMD SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F SMALL CELL SHROUD BY OTHERS. SHROUD SHALL BE SECURELY FASTENED TO THE TOP OF POLE VIA `IO 00". A36 STEEL, PAINT SPECIFICATIONS: � NUTS AND BOLTS, MOUNTING DETAILS PER POLE .�0 1 J¢" THICK ALL LUMINAIRE, POLE, CAST ALUMINUM MANUFACTURER. OTHERWISE PROVIDE POLE CAP 0 - y BASE PLATE BASE PARTS, AND ANY ADDITIONAL ALUMINUM SHROUD CO EQUIPMENT MOUNTED ON THE POLE4EN1N.S,, MANUFACTURER) SHALL BE FACTORY PRIMED AND POWDER 15"0 BOLT CIRCLE COATED TO MATCH FINISH COLOR.DOME STYLE LED LUMINAIRE (WATTAGE PER (6) 1.38" DIA. HOLES WITH 1 1/4° PLANS TYPE 3 IES DISTRIBUTION 4000K CCT DIA 4" HEX HEAD CONNECTING _ ( BOLTS AND NUTS ALL BANDING AND ALL OTHER MOUNTING ,�120-277V UNIVERSAL DRIVER 750mA OR HARDWARE SHALL MATCH FINISH COLOR. -� LOWER), WITH FLAT GLASS LENS) BY CYCLONE (OR APPROVED EQUAL) DRIVER SHALL BE POLE BASE PLATE DETAIL FINISH COLOR: RAL 9005TX "JET BLACK",INTEGRAL TO THE FIXTURE. FOR MOUNTING ARM 3'-0' OR APPROVED EQUAL WITH PAINT CHIPDETAILS SEE STD PLAN 117.3. WIRING PER STD DECORATIVE LUMINAIRE POLE NOTES `i PLAN 119. ONE 2" CONDUIT, UNLESS STATED OTHERWISE ON THE PLANS. STUBOUT V _ e OT ROUND TUBULAR SECTON FROM EDGE OF CONCRETE FOUNDATION (NO TAPER) AND CONNECT TO CITY JUNCTION BOX PER STD PLAN119 ONE 2° CONDUIT, STUBOUT 1' FROM EDGE OF CONCRETE FOUNDATION, 1 3 OF POLE SPACE FOR 90 E R CONNECT TO CARRIER JUNCTION BOX, CARRIER ORIENTED OR TYPE 1 OR TYPE 2 JUNCTION BOX 270' FOR LENGTH OF POLE FOUNDATION SECTION 0 GROUND POLE TO FOUNDATION CONDUITS, SEE FOUNDATION SECTION, PER STD PLAN 119 180' 0' F THIS SHEET 5 ANCHOR BOLTS, SEE ANCHOR BOLT' o ASSEMBLY DETAIL, THIS SHEET "' x TOP OF CONCRETE PAD/SIDEWALK 270' 2/3 OF POLE SPACE FOR INTERIOR WALL CITY/UTILITY POLE CHAMBER DETAIL DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, TYPE 3 IES DISTRIBUTION, 4000K OCT, 120-277V UNIVERSAL DRIVER (750mA OR LOWER), IWTH FLAT GLASS LENS) BY CYCLONE (OR APPROVED EQUAL) DRIVER SHALL BE INTEGRAL TO THE FIXTURE. 4'-0' FOR MOUNTING ARM DETAILS SEE LUMINAIRE STD PLAN 117.3. WIRING PER STD PLAN 119.- FOR STREET LIGHT STANDARD DECAL NUMBERING DETAIL, REFER TO CITY OF RENTON STD PLAN 121 i 3 A595 GR. A, 55KSI, 2 o TAPERED STEEL POLE SHAFT, 35.75' LONG, 0.209" THICK, 10.83" BOTTOM O.D., j 5.83' TOP O.D. � o z (2) STEEL 4" x 10" HAND 4o HOLE WITH COVER AND NUT HOLDER WITH FASTENERS FOR m GROUNDING ALUMINUM BASE COVER, SEE STANDARD DETAIL 117.1E " REBAR PER STRUCTURAL ANALYSIS ir 3 a .i a� is J o Ko� zu, 90. " 180' -0' 4,? I o� 270 FOUNDATION DETAIL m • DECORATIVE ROADWAY LUMINAIRES ARE MOUNTED AT 0' 1.38" DIA. HOLE (TYP) • DECORATIVE PEDESTRIAN LUMINAIRES 1" THICK STEEL PLATE ARE MOUNTED AT 180' • HANDHOLES ARE MOUNTED AT 180' BOLT CIRCLE PER \ PLESE ATHISPLATE I ORIENTATION LOCATION DE AIL,, SHEET ANCHOR BOLT TEMPLATE DETAIL TOP OF FOUNDATION ANCHOR BOLT TEMPLATE (TYP)- ANCHOR BOLT, 4 TOTAL, 1 Y." DIA., STEEL F1554 OR GRADE 55, a 6" HIGH SIDEWALK () a OR PLANTER STRIP 1 Y° HEX NUTS (6 REQ'D PER < ANCHOR BOLT), AND rl FLAT WASHERS (6 REQ'D PER ROADWAY ANCHOR BOLT) CONCRETE PAD/SIDEWALK PER STD PLAN 120J � • :.. �IF SURFACE IS NOT LEVEL, INSTALL GROUT AT ANCHOR BOLT ASSEMBLY DETAIL SEE FOUNDATION DETAIL, THIS SHEET. EDGE OF BASE OF POLE AND BASE COVER, PROVIDE 1/2" FOUNDATION NOTES FOUNDATION SHALL BE LOCATED AT LEAST 5' DIA. DRAIN TUBE THROUGH GROUT 1. SONOTUBES SHALL NOT BE ALLOWED AWAY FROM CITY TI TI N THERWISE O C U U ES UNLESS 0 ///AI�Y 2. ALL FOUNDATION HARDWARE SHALL BE HOT -DIPPED GALVANIZED IN APPROVED BY THE CITY- ACCORDANCE WITH THE LATEST WSDOT STANDARD SPECIFICATION POLE ELEVATION SECTION 9-29.6(5) FOUNDATION HARDWARE FOUNDATION DETAILS ARTERIAL STREET STD. PLAN - 117.1A PUBLIC WORKS SMALL CELL DECORATIVE .� . APPROVED: DEPARTMENT LUMINAIRE POLE DETAILS 7/27/2022 1 [Martinastucha DATE DocuSign Envelope l D: 9D980DAB-0385-4664-AE66-57BFF1561D7F T-O" LUMINAIRE POLE \ L JUNCTION BOX CONCRETE PAD, PLAN MEW BROOM FINISH LUMINAIRE POLE CONCRETE PAD 4- -JUNCTION BOX LUMINAIRE CONCRETE FOUNDATION SIDE VIEW LUMINAIRE CONCRETE PAD DETAIL GENERAL NOTES: 1. LUMINAIRE CONCRETE PAD SHALL BE USED IN AREAS OUTSIDE OF SIDEWALK 2. CONCRETE CLASS FOR LUMINAIRE CONCRETE PAD SHALL BE PER STD PLAN 135 3. TOP OF LUMINAIRE FOUNDATION ELEVATION SHALL BE LOCATED AT BOTTOM OF LUMINAIRE CONCRETE PAD ELEVATION OR BOTTOM OF SIDEWALK ELEVATION 4. LUMINAIRE POLE AND JUNCTION BOX TYPE PER PLAN 5. LUMINAIRE CONCRETE PAD ACCOMMODATES TYPE 1 AND TYPE 2 JUNCTION BOXES ONLY PLAN VIEW yPER STD PLAN102 LUMINAIRE POLE CONCRETE SIDEWALK PER STD PLAN 102 -JUNCTION BOX LUMINAIRE CONCRETE FOUNDATION SIDE VIEW LUMINAIRE WITH SIDEWALK DETAIL CONCRETE PAD JUNCTION BOX J/ PLAN MEW 4" CONCRETE PAD JUNCTION BOX SIDE MEW INDIVIDUAL JUNCTION BOX PAD DETAIL ° LUMINAIRE CONCRETE STD. PLAN - 120 PUBLIC WORKS PAD/SIDEWALK AND p ? DEPARTMENT JUNCTION BOX CONCRETE PAD APPROVED:Martin Pastucha 7/27/2022 DA� T-433003 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TRANSPORTATION OPERATION DEVELOPMENT ENGINEERING ` C TY OF RENTON Plan ning/Building/Public Works Dept. cbarnes 08/07/2025 yqi 08/07/2025 LOJ L O N U O 0 O I N rr LU J �0 DATE: V J SOLERRA 07.28.2025 FIELDBOOK: ILLUMINATION PLAN DETAILS PAGE: DRAWING NO: 10823, 10815, 10824 145TH PL SE IL-03 RENTON, WASHINGTON 98059 SHEE7:3 OF:5 TENW PROJECT NO. 2024-276