Loading...
HomeMy WebLinkAboutT-433004SE 7/4 SECTION 3, TOWNSHIP 23 N, RANGE 5 E, W.M. SOLERRA in T I O rr z J U_ DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F INSTALL DECAL NUMBERS/LETTERS VERTICALLY. DECAL NUMBERS/LETTERS, SEE NUMBERING EXAMPLE, THIS SHEET. SHALL BE INSTALLED IN DRY WEATHER, 50F OR ABOVE 1 2 3 4 C 5 = 6 7 Z 0 NUMBERING EXAMPLE MOUNTING HEIGHT DETAIL 1-3/4" TO 2" 90, PEDESTRIAN SCALE CURB DECAL TRAFFIC FLOW DECALORENTATNIN FOR POLES SHOWN ON STD PLAN 11&1 90. PEDESTRIAN SCALE DECAL PEDESTRIAN SCALE �ZURB CURB DECAL TRAFFIC TRAFFIC FLOW FLOW DECAL ORIENTATION FOR POLES SHOWN ON STD PLAN 1172 /-PEDESTRIAN SCALE Y SCALE TRAFFIC FLOW DECAL ORIENTATION FOR POLES SHOWN ON STD PLAN 117.1 & 117.1A 0� ROADWAY SCALE DECAL PEDEFnVAN SCALE DECAL DECAL NOTES: 1. DECALS SHALL BE REFLECTORIZED, GOTHIC FONT, GOLD OR WHITE LEGEND ON BLACK BACKGROUND Y LUMINAIRE STANDARD DECAL STD. PLAN - 121 PUBLIC WORKS NUMBERING SYSTEM • . APPROVED: p DEPARTMENT Martin Pastucha 7/27/2022 N T DATE DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F CONDUIT ENTRANCE AREA, SEE NOTE 13, STD PLAN 126.2 a a O"0 g' .e SEE STD PLAN 126.2 FOR ADDITIONAL NOTES ,a PLAN VIEW SIZE TO FIT SIZE TO FIT CABINET CABINET 6" 6" 1'-0" 1,-On `-4 1 1L -GRADE LEVEL .aL ;lip' J. ... N .aQ n FRONT VIEW SIDE VIEW ELECTRICAL SERVICE CABINET FOUNDATION SEE STD PLAN 126.2 FOR ADDITIONAL NOTES SHIM TO PLUMB SEE NOTE 3 o #4 HOOPS IIT 4 BAR EEAC I CORNER - - - - ,. `6" MIN 1» TO 2" 3/8" DIAMETER PLASTIC DRAIN SIDE VIEW CABINET DEPTH V-6" + 2" V-6" - - - - - #4 BAR EACH UU I + i #4 CORNER z m _ _ _ �I+ _HOOPS IIII Liu PLAN VIEW CONDUIT ENTRANCE AREA, SEE NOTE 5, STD PLAN 126.2 CONTROLLER CABINET FOUNDATION Y o� CABINET FOUNDATION STD. PLAN - 126.1 • ° PUBLIC WORKS DETAILS APPROVED: DEPARTMENT 7/27/2022 1 'p Martin Pastucha N T �DATE r� Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,IMT,ND,OR,WA) 07-28-2025 DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E560AA1F5959 z O oGo ULU ) lV M z O Q W J w H- =LIU UJZCDU> LLjwpH J2 W W Z--Q<n DDH H Z UNQ� w OZOU w 2 Z 2 z �D wo2l-o w w m 2 H H LLF- WO W H- W=_jLL OwQ�W W J Y 10 <0 J Z( W ~ W U Q Q O (D 0Qm0- Z�Z U)-(DH W--LL W 2 H ¢o O 0 2W =z ILL.LC O � oa�z U)O O W=)-0 CO Www ofZa(D �Zw U)U)oZ W wow w w w _ O H 2 H J w LLIQZJ ED Q = w U J H Z Q Q m o = 8 C E0 tea) �o F- of ro� LU In ww zIII U) j OAF Wm 2 , �Qw 0 Q:LLUI U V Ix N N z a Q r}- 0- N D' Q 0 H Z z a. U Of O Uj O o w U) W H O z w o' m Lj In Q o_ w CD z J) CD N C) v o� SERVICE CABINET T.A.. PLAN - 122.1 + PUBLIC WORKS �pPgOV D: DEPARTMENT Marton PaStuCfY218/2021 4: F N - DATE DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFF1561D7F ELECTRICAL SERVICE/BBS CABINET CONTROLLER CABINET SHIM TO PLUMB SEE NOTE 3 - /4 REINFORCING BAR (EQUAL SPACES) SEE NOTE 5 - NOTES 1. WHERE FOUNDATION PAD IS LOCATED WITHIN A SIDEWALK, CONSTRUCT PAD TOP FLUSH WITH SIDEWALK GRADE, OMITTING CHAMFER WHERE TOP AND SIDEWALK ABUT. MOUNT TOP SHALL BE FINISHED BY A CONCRETE CONTRACTOR AND SHALL MEET THE REQUIREMENTS OF SECTION 8-14.3 IN THE WSDOT STANDARD SPECIFICATIONS. 2. PAD MOUNT DESIGN IS TYPICAL 3. PLACE A SILICONE SEAL BETWEEN THE FOUNDATION AND CABINET. 4. ANCHOR BOLTS AND THEIR SPACING TO BE SUPPLIED BY CABINET MANUFACTURER AND SUBMITTED TO THE ENGINEER FOR APPROVAL. 5. CONDUIT SIZES/QUANTITIES FOR CONTROLLER CABINETS SHALL BE INSTALLED PER THE CONTRACT PLANS, PLUS ONE 2" SPARE CAPPED OUT PAST THE FOUNDATION. 6. CONCRETE CLASS PER STD PLAN 135. 7. 2" CONDUIT SHALL BE PLACED FROM THE ELECTRICAL SERVICE/BBS CABINET TO THE CONTROLLER CABINET. B. EACH CABINET SHALL HAVE A %" DIAMETER PLASTIC DRAIN PIPE. 9. LOCATE CONDUITS CENTRALLY WITHIN THE CABINETS. 10. WHEN ALL THREE CABINETS ARE TO BE INSTALLED AND SPACE ALLOWS, A COMBINED FOUNDATION SHALL BE USED. 11. WOODEN SHIMS SHALL NOT BE USED 12. GROUNDING SHALL BE PER WSDOT STANDARD PLAN J-60.05, SHEET 3. - 13. CONDUIT SIZES/QUANTITIES FOR ELECTRICAL SERVICE CABINETS SHALL IB BE INSTALLED PER THE CONTRACT PLANS, PLUS ONE 2" SPARE CAPPED OUT PAST THE FOUNDATION. SHIM TO PLUMB ESE�SEE NOTE 3 2" FRONT VIEW Lj 3/8" DIAMETER PLASTIC DRAIN (ONE PER CABINET) SEE NOTE 7 3/8" DIAMETER PLASTIC DRAIN -SEE NOTE 13 3 - #4 REINFORCING BAR (EQUAL SPACES) N U -I F HORIZONTAL COMBINED FOUNDATION RE" BAR DIAGRAM 6 PIECES PLAN VIEW COMBINED CONTROLLER/ELECTRICAL SERVICE/BBS FOUNDATION Y CABINET FOUNDATION STD. PLAN - 126.2 PUBLIC WORKS DETAILS • ° APPROVED: DEPARTMENT °�°-•°� 7/27/2022 [ ;;r,;astucha DATE EML 17 400 520 KIRKLAND WAY, SUITE 100, KIRKLAND, WA, 98033 STELLA OH I STELLA@TENW.COM 1 206-412-6743 REVISION DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E56OAA1F5959 UOMPONIEN"1' SCHEDULE OMETERBASE: 200 AMP, 4 JAW, MANUAL BYPASS, B-LINE U264 W/ 5TH JAW AT 9:00 POSITION OPANELBOARD: 120/240 VAC, 125 AMP COPPER BUS, 1 PHASE, 3 WIRE, 18 CKT, I OK AIC MAIN BREAKER: 200 AMP FRAME, 200 AMP TRIP, 2 POLE, EATON ED2200 BOLT -ON BRANCH BREAKERS, EATON TYPE BAB: 2 - 20/2 ILLUMINATION A, B I - 20/1 ITS I - 20/1 GROUND FAULT RECEPTACLE I - 40/1 SIGNAL (IF PRESENT) I - 40/1 AUXILLIARY SIGNAL (IF PRESENT) 2 - 60/2 SMALL CELL BRANCH I - 1511 CONTROL 3 - 20/1 SPARE OCONTACTOR: NEMA LIGHTING RATED, 30 AMP 4 POLE, 120 VAC COIL, SQD 891ODPA34VO2 -I REQUIRED OPHOTO ELECTRIC CELL: 1800 WATT, 120 VAC, TWIST LOCK, ALR #SST-IES-UL MOUNTED INSIDE CABINET BEHIND WIREGLASS WINDOW OPHOTO -CELL BYPASS SWITCH: SPDT, 15 AMP, RATED (UP TO) 277 VAC (FED THROUGH TERMINAL BLOCK) GROUND FAULT RECEPTACLE: 20 AMP, 125 VAC, DUPLEX O CABINET: CONSTRUCTION: NEMA TYPE 3R, OUTDOOR PADMOUNT, 1/8" 5052-H32 ALUMINUM CONSTRUCTION, OPEN BOTTOM FRAMED WITH 2" ANGLE, 2 SCREENED AND GASKETED VENTS, REMOVABLE EQUIPMENT MOUNTING PAN, CABINET GROUND WITH MINIMUM BONDING WIRE TO NEUTRAL DOORS: HEAVY-DUTY CONCEALED HINGES (LIFT-OFF TYPE),STAINLESS STEEL VAULT HANDLES WITH ROLLER RODS THAT PROVIDE 3-POINT COMPRESSION ON CLOSED CELL NEOPRENE GASKET, "BEST" LOCK ON LOWER DISTRIBUTION DOOR WITH CARD HOLDER, PADLOCKABLE UPPER METER DOOR WITH POLISHED SAFETY GLASS WINDOW DEADFRONT: HINGED AND SECURED WITH QUARTER -TURN FASTENERS FINISH: MILL FINISH ALUMINUM 1 - REQUIRED UL LISTED PER STANDARD #508A "SUITABLE FOR USE AS SERVICE ENTRANCE" NOTE: 1. SIGNAL BREAKER(S) SHALL BE ADDED WHEN APPLICABLE SERVICE CABINET NOTES T PLAN - 122.2 PUBLIC WORKS .._L D: A DEPARTMENT Martin APPROV�aStLIClJl48/2021 4 DATE DocuSign Envelope ID: 894DB72E-3255-4A63-AOF1-38A20AAF74CA GENERAL NOTES: 1. ALL EXISTING TRANSPORTATION INFRASTRUCTURE FEATURES SHALL BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 2. ALL TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 3. ALL EXISTING OR PROPOSED TRANSPORTATION INFRASTRUCTURE FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT PROWAG ADA STANDARDS (I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). 4. ALL NEW TRAFFIC SIGNALS SHALL BE CONSTRUCTED WITH FIBER COMMUNICATION CONNECTION TO CITY OF RENTON TRANSPORTATION FIBER OPTIC NETWORK. 5. ALL TRANSPORTATION INFRASTRUCTURE FEATURES THAT ARE TO BE REMOVED AND REINSTALLED AT A LATER DATE SHALL BE RE -INSTALLED TO CURRENT STANDARDS. 6. ALL CONDUIT SHALL BE PVC SCHEDULE 80. 7. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 8. ALL PROPOSED SIGNAL POLE FOUNDATIONS AND EXISTING MODIFIED SIGNAL POLE FOUNDATIONS SHALL INCLUDE A CONCRETE PAD AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK SHALL BE CONSIDERED PART OF THE FOUNDATION PAD. FOUNDATION PAD SHALL BE AT LEAST 2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS OR UNLESS OTHERWISE APPROVED. 9. WHEN THE TRAFFIC SIGNAL IS OPERATIONAL, ALL DETECTION SHALL BE MAINTAINED AND REMAIN FUNCTIONAL FOR ALL SIGNAL PHASES. NEW PERMANENT/TEMPORARY VIDEO DETECTION SHALL BE INSTALLED AND OPERATIONAL PRIOR TO DESTROYING ANY EXISTING DETECTION. 10. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION MAINTENANCE PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION MAINTENANCE MANAGER OR OTHER TRANSPORTATION REPRESENTATIVE. 11. NEW PTZ CAMERA SHALL BE REQUIRED WHEN A NEW TRAFFIC SIGNAL SYSTEM IS INSTALLED, WHEN LANE CONFIGURATION IS MODIFIED WITH NEW SIGNAL PHASING, AND/OR WHEN EXISTING PTZ CAMERA(S) REQUIRE RELOCATION. 12. ARROW BOARDS SHALL BE REQUIRED TEMPORARY TRAFFIC CONTROL WHEN CLOSING A TRAVEL LANE AND SHALL BE MUTCD COMPLIANT. TRANSPORTATION NOTES STD. PLAN - 135 PUBLIC WORKS P, OVED: DEPARTMENT 5/2/2024 1 'fMartin Pastucha F N T DATE SURVEYED: OTHERS DESIGNED: DRAWN: ARC ARC CHECKED: SSO/GMD BY DATE A P P R APPROVED: GMD SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVE) 1988 HORIZONTAL: NAD 1983/1991 DATUM CITY OF 1;R] NbZVF RENTON Planning/Building/Public Works Dept. 11 1 1/4" LOAD LINE 1/4" FUSE I O CUTTING RINGS FUSE KIT VV T C 3r LII.0 SPLICE KIT FUSE KIT & SPLICE KIT DETAILS ADOPTED CITY OF RENTON ♦ + STANDARD PLANS 1ST DATE: 04/04 .... ., nwr MAXAF•..In l l Sp par;-- X)1 3 T-433004 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TRANSPORTATION OPERATION DEVELOPMENT ENGINEERING N M C) C) N U C) C) 0 0 N � - :0a cbarnes 08/07/2025 yqi 08/07/2025 W I �O DATE: V J SOLERRA 07.28.2025 FIELDBOOK: ILLUMINATION PLAN DETAILS PAGE: DRAWING NO: 10823, 10815, 10824 145TH PL SE IL-04 RENTON, WASHINGTON 98059 SHEET: 4 OF:5 TENW PROJECT NO. 2024-276