Loading...
HomeMy WebLinkAboutR-43782200 C'O I O I LL1 12" PVC OVERFLOW TO CB#35 LADDER RUNG LADDER RUNG 12" PVC INLET FROM 2" 90' ELBOW VAULT A 2" SCH. 80 THRUST BLOCKS DISCHARGE PIPES (TYP.) 2" TEE 2" DISCHARGE TO SINGLE CHECK VALVE PLAN VIEW 2" VENT PIPE '" OVERFLOW TO CB#34 3" SCH. 80 DISCHARGE PIPE 3" TEE AND REDUCER 4" SCH, 80 PIPE TO 4" SINGLE CHECK VALVE THRUST BLOCK (TYP) �12' PVC INLET FROM VAULT 62 PLAN VIEW 2" VENT PIPE CONTROL CABLE RIM ELEVATION = 478.5t CONTROL CABLE RIM ELEVATION = 475.5t MOUNTING BRACKET ACCESS HATCH, MODEL LW MOUNTING BRACKET ACCESS HATCH, MODEL LW HATCH, D-2, 48 x 60 HATCH, D-2, 48" x 60" CONDUIT TO JUNCTION BOX CONDUIT TO JUNCTION BOXES LIFTING CHAIN, BARNES °. •. �(. Igipl IN ACCORDANCE WITH IN ACCORDANCE WITH CHAIN, BARNES APPLICABLE ELECTRICAL - pll7 APPLICABLE ELECTRICAL Ig CODE REQUIREMENTS I CODE REQUIREMENTS (SEE NOTE 7) POWER SENSOR (SEE NOTE 7 AND 8) 12" PVC OVERFLOW CABLES IE=471.00 12" PVC OVERFLOW �- (TO CB#34) 1E=476.33 POWER SENSOR (TO CB#35) -► 2 SCH. 80 ,; 4" SCH. 80 GUIDE RAIL PIPE DISCHARGE PIPE CABLES DISCHARGE PIPE BARNES TO SINGLE CHECK GUIDE RAIL PIPE TO SINGLE CHECK (SEE NOTE 6) IE=475.50 BARNES IE=470.50 (SEE NOTE 5) (SEE NOTE 6) `,�x, (SEE NOTE 5 AND PLAN VIEW) �� fi 12" PVC INLET FROM HIGH WATER ALARM DETENTION VAULT B1 EL=468.00 -•-12" PVC INLET PIPE IE=461.60 FROM DETENTION SEE SEE NOTE 1 VAULT A IE=468.00 HIGH WATER NOTE 1 . ` ALARM 12" PVC INLET FROM PUMP ON ,� 2" DISCHARGE PIPE EL=460.85 DETENTTION VAULT B2 EL=467.25 2ND 3" DISCHARGE PIPES 1ST t PUMP ON PUMP ON BASIN BOTTOM EL=460.94 BASIN BOTTOM EL=466.75 EL=464.50 1ST EL=454.32 PUMPS OFF PUMP ON EL=465.70 EL=460.44 ALARM EL=465.50 °: PUMPS OFF e' °: , ° °' y. . EL=456.24 HOPPER BOTTOM T5PLATE E ALARM HOPPER BOTTOM T BASE PLA L=456.04 BASE E " ELBOW 4" DISCHARGE ELBOW PUMP CHAMBER ASSEMBLY&aowlocw�MP CHAMBER B ASSEMBLY M 72" CATCH BASIN, 2 HYDRAULIC SEALING FLANG N 72 ATCH BASIN, TYPE 2 HYDRAULIC SEALING FLANGE NOTES: Affvlowfo OTES: 1. DUPLEX SYSTEM, TWO 0. 2" SUBMERSIBLE, NON -CLOGGING PUMPS SINGLE 1. DUPLEX SYSTEM, TWO 1.5 " SUBMERSIBLE, NON -CLOGGING EXPLOSION PROOF PUMPS, PHASE; 23OV, MODEL 21, SINGLE PHASE, 23OV, B NES ODEL 3XSE1524EA. 2. TWO 2 BREAK AWAY FITTINGS. 2. TWO 3 BREAK AWAY FITTINGS, 3. PEDESTAL CONTROL PANEL: BARNES DUPLEX CONTROL PANEL, 0.4 HP PUMPS, 3. PEDESTAL CONTROL PANEL: BARNES DUPLEX CONTROL PANEL, 1.5 HP PUMPS (EXPLOSION PROOF) 230V, 1 PH WITH ALTERNATOR, RUN LIGHTS, H-O-A SWITCH, BI-METAL OVERLOAD 23OV, 1 PH WITH ALTERNATOR, RUN LIGHTS, H-O-A SWITCH, BI-METAL OVERLOAD RELAY CIRCUIT BREAKER FOR SHORT CIRCUIT PROTECTION. RELAY CIRCUIT BREAKER FOR SHORT CIRCUIT PROTECTION. NEMA 3R STEEL ENCLOSURE WITH ALARM LIGHT, BELL, LIGHTNING ARRESTER, NEMA 3R STEEL ENCLOSURE WITH ALARM LIGHT, BELL, LIGHTNING ARRESTER, MASTER CB, MOISTURE SENSORS AND TEST RELAYS, TEMPERATURE SENSORS, LAMASTER CB, MOISTURE SENSORS AND TEST RELAYS, TEMPERATURE SENSORS, PUMP SEQUENCE SELECTOR SWITCH. (INCLUDE INTRINSICALLY SAFE RELAYS IF Q PUMP SEQUENCE SELECTOR SWITCH AND 3 INTRINSICALLY SAFE RELAYS. REQUIRED BY APPLICABLE ELECTRICAL CODE). 9" 4. CONTROL PANEL PEDESTAL KIT: DUPLEX CONTROL PANEL PEDESTAL KIT: DUPLEX 5. 2" DISCHARGE SCH. 80 PIPE TO 2" SINGLE CHECK VALVE. SEE PLAN VIEW. 4" DISCHARGE SCH. 80 PIPE TO 4" SINGLE CHECK VALVE. SEE PLA N VIEW. 6. LISTING CHAINS AND INTERMEDIATE RAIL SUPPORTS PER MANUFACTURES' RECOMMENDATIONS. 6. LIFTING CHAIN AND INTERMEDIATE RAIL SUPPORTS PER MANUFACTURES' RECOMMENDATIONS. 7. PUMP/FLOAT JUNCTION BOX (PER APPLICABLE ELECTRICAL CODE REQUIREMENTS) 7. FLOAT JUNCTION BOX (PER APPLICABLE ELECTRICAL CODE REQUIREMENTS) 8. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS TO ENGINEER FOR APPROVAL. 8. EXPLOSION PROOF PUMP JUCTION BOX, NEMA 7 (PER APPLICABLE ELECTRICAL CODE REQUIREMENTS) 9. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS TO ENGINEER FOR APPROVAL, BLOCKING DETAIL �)THRUST NTS z� �z N 10 OVERFLOW ELEV. TO PROVIDE DETENTION & OIL SEPARATION PER PLANS PIPE SUPPORT(S): 3" X .090" 1'-0" MIN. OUTLET PIPE INVERT ELEVATION 469.00 RESTRICTOR PLATE ORIFICE 0.50" REMOVABLE WATER- TIGHT COUPLING 6" MAX. PLATE WITH ORIFICE AS SPECIFIED ELBOW DETAIL FLOW RESTRICTOR 'A' H. MAX. W.S. 477.00 r--4" ELBOW IIIIIII 46P on z?� c0 :. I ' N � OVERFLOW ELEV. TO PROVIDE DETENTION & OIL SEPARATION PER PLANS SEE NOTE 10. PIPE SUPPORT(S): 3" X .090" 1'-0„ MIN. OUTLET PIPE INVERT ELEVATION 463.00 RESTRICTOR PLATE ORIFICE 1.04" ROUND SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS, SEE DWG. NOS. 2-022 & 2-023. FRAME & LADDER OR STEPS OFFSET. SEE NOTE 8. FRAME & COVER ELEV. PER PLAN. ORIFICE=0.75" CLEANOUT GATE: SHEAR GATE. SEE DWG. NO. 2-026. STEPS OR LADDER. SEE DWG. NO. 2-006. PLAN ROUND SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS. SEE DWG. NOS. 2-022 & 2-023. FRAME & LADDER OR STEPS OFFSET. SEE MAX. W.S. 470.00 NOTE 8. FRAME & COVER ELEV. PER PLAN 4" ELBOW ELEV.=469.40 ORIFICE=2.79" 6 ELBOW ELEV.=466.65 ORIFICE=1.62" CLEANOUT GATE: SHEAR GATE. SEE DWG. NO. 2-026. STEPS OR LADDER. SEE DWG. NO. 2-006. I 4 .; .. CN :..7. 777 KING COUNTY D.D.E.S. REVIEW ENGINEER COMPLETION DATE SENIOR ENGINEER COMPLETION DATE JAMES H. SANDERS, P.E. APPROVAL DATE DEVELOPMENT ENGINEER COMMENTS: NOTES: 1. PIPE SIZES AND SLOPES: PER PLANS. 2. OUTLET CAPACITY: NOT LESS THAN COMBINED INLETS. 3. EXCEPT AS SHOWN OR NOTED, UNITS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE REQUIREMENTS FOR CATCH BASIN TYPE 2, 54" MIN. DIAM. 4. PIPE SUPPORTS AND RESTRICTOR/SEPARATOR SHALL BE OF SAME MATERIAL, AND BE ANCHORED AT 3' MAX. SPACING BY 5/8" DIAM. STAINLESS STEEL EXPANSION BOLTS OR EMBEDDED 2" IN WALL. 5. THE RESTRICTOR/SEPARATOR SHALL BE FABRICTED FROM .060" ALUMINUM, OR .064" ALUMINIZED STEEL, OR .064" GALVANIZED STEEL PIPE; IN ACCORDANCE WITH AASHTO M 36, M 196, M 197 AND M 274. GALVANIZED STEEL SHALL HAVE TREATMENT 1. 6. OUTLET SHALL BE CONNECTED TO CULVERT OR SEWER PIPE WITH A STANDARD COUPLING BAND FOR CORRUGATED METAL PIPE, OR GROUTED INTO THE BELL OF CONCRETE PIPE. 7. THE VERTICAL RISER STEM OF THE RESTRICTOR/SEPARATOR SHALL BE THE SAME DIAM. AS THE HORIZONTAL OUTLET PIPE, WITH AN 8" MIN. DIAM. 8. FRAME AND LADDER OR STEPS OFFSET SO THAT: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C. FRAME IS CLEAR OF CURB. 9. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO A CONCRETE PIPE I.D. LESS 1 /4". 10. MULTI -ORIFICE ELBOWS MAY BE LOCATED AS SHOWN OR ALL ON ONE SIDE OF RISER TO ASSURE LADDER CLEARANCE. z� `1' MAX. W.S. 470.00 OVERFLOW ELEV. TO PROVIDE DETENTION & OIL SEPARATION PER PLANS SEE NOTE 10. 4" ELBOW PIPE SUPPORT(S): 3" X .090" MIN. OUTLET PIPE 461.00 INVERT ELEVATION 461,00 18" RESTRICTOR PLATE ORIFICE 0.69" • ' 4MIN.KING COUNTY D.D.E.S. I BUILDING SERVICES D SION C0I�Ii E LCT . FIRR VAI Project No. Proj Name SITE FNNGINEERING/DRAI R®V - DA E ,/'A" SIGNED AT 'EI�AEi�. LA.NNING APPPOVfil, FLOW RESTRICTOR B1 DAXE SIGNS -fA-ANDSCAPE/ZONING/PA RMNG DATE -___._____-_SIGNED --'' ;APE 1AI, CONDITIONS: I. 4' MIN.• j ROUND SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS. SEE DWG. NOS. 2-022 & 2-023. FRAME & LADDER OR STEPS OFFSET. SEE NOTE 8. FRAME & COVER ELEV. PER PLAN. ELEV.=469.17 ORIFICE=1.55" ELEV.=466.60 ORIFICE=1.26" CLEANOUT GATE: SHEAR GATE. SEE DWG. NO. 2-026, STEPS OR LADDER. SEE DWG. NO. 2-006. 11N%►L CORRECTED PLAN DATE: 91e�-71eC_ APPROVED_ FLOW RESTRICTOR ' B2' DESIGNED JW DRAWN DP CHECKED 8 17 01 DATE _ SCALE NTS ENGINEERING, INC. ��o �sxl r� w ,. a b �03 9 a�WW 0NAL \�t4� OWNER/DEVELOPER: PDSK PROPERTIES, INC. 621 PACIFIC AVE. SUITE 300 98402 TACOMA, WA. ! TITLE: RESTRICTOR AND PUMP CHAMBER DETAILS 10836 SE 190TH ST. BELGROW AT UNTON KING COUNTY WASHINGTON SHEET 7 of 10 (253)565-4491 • Seattle (206)824-1205 • FAX (253)565-8563 Land Planning & Use . Engineering . Surveying 1910-64th Avenue West, a Tacoma, WA 98466 - J06 No. 01-065 1 3/10/03 JW CSDP REVISION EXPIRES: 05-24-All No. Date B A r. Revision R-437822