Loading...
HomeMy WebLinkAboutMFP25003080.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP25003080 IVR Number: 25003080 Permit Information Permit Name: JB0002151539 Address/Location:06/19/2025Application Date:3123059023Parcel Number: 5301 TALBOT RD S Permit Type:07/30/2025Issue Date:Franchise Permit Work Class:07/30/2026Expiration Date:Major Utility Job Number: JB0002151539Franchise Type:Cable Description: Comcast Construction to consist of placing new comcast aerial splice cases, replace existing comcast doghouse with new SPH2436 pedestal. Access existing comcast pedestal for maintenance. Access existing comcast vault for maintenance at proposed locations. Restoration per City of Renton standards. Contacts Name Address PhoneTypeBilling Leah Ihlenfeldt Cablecom LLC 1316 Bonneville Avenue Snohomish, WA 98290 B: (360) 670-4291ApplicantX CODY SHACKETT COMCAST H: (253) 341-9318Contact CABLECOM LLC 20021 120th Ave NE, #101 BOTHELL, WA 98011 B: (360) 668-1300Contractor Business License Number: 52252Construction Contractor: CABLEL*971DP SENTINEL REAL ESTATE 1251 6TH AVE 24TH FLOOR NEW YORK , NY 10020 Owner General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES -- --- -- MFP25003080 Scott Warlick CED 12/1/2025 Type text here CONSTRUCTION TO CONSIST OF PLACING NEW COMCAST AERIAL SPLICE CASES, REPLACE EXISTING COMCAST DOGHOUSE WITH NEW SPH2436 PEDESTAL, ACCESS EXISTING COMCAST PEDESTAL FOR MAINTENANCE, AND ACCESS EXISTING COMCAST VAULT FOR MAINTENANCE AT PROPOSED LOCATIONS. ALL CONSTRUCTION AND RESTORATION TO MEET OR EXCEED CITY OF RENTON STANDARDS. MFP25003080 Monday Friday 3:00pm Scott Warlick CED 12/1/2025 9:00am SPENCER KARINIEMITRAFFIC CONTROL SUPERVISOR360-722-2852NOTES:1. ALL SIGNS ARE 36"-48" ACROSS2. ASTERISK DENOTES X, L, OR B DISTANCES ARE NOT TO SCALE3. CONTRACTOR SHALL ALWAYS PROVIDE ACCESS TO DRIVEWAYS4. STANDARD ADVANCE WARNING SIGNS SHALL BE USED FOR PLATES OR ROUGH ROAD DURING AFTER-HOURS, INCLUDING "MOTORCYCLIST" SIGN5. FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302. UPO WILL BE REQUIRED IF A TRAFFIC SIGNAL COULD BE COUNTERMANDED6. IF ONLY ONE LANE IS OPEN IN A DIRECTION, THAT LANE SHALL BE A MINIMUM OF 11' WIDE, UNLESS SPOTTER/FLAGGERS ARE USED, IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'7. SIDEWALKS ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OF CURBRURAL ROADS & URBAN ARTERIALSRURAL ROADSRESIDENTIAL & BUSINESS DISTRICTSURBAN STREETSRURAL ROADS & URBAN ARTERIALS350'±500'±100'±200'±(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATEINTERCHANGE RAMPS, AT-GRADE INTERSECTIONS ANDDRIVEWAYS(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TOFIT ROADWAY CONDITIONSSIGN SPACING = X35/40 MPH45/55 MPH25 MPH OR LESS25/30 MPHCHANNELIZATION DEVICESPACING (FEET)35/4525/3050MPHTAPER403020406080TANGENT150251051151253530165180205225245402702953204545049554050500550600101112LANEWIDTH(FEET)MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED (MPH)TRAFFIC CONTROL PLANN O R T H253035404550556065645570495425360305250200155LENGTH (FEET)SPEED (MPH)LONGITUDINAL BUFFER SPACE = BBUFFER DATA20115TYPE OF TCP: WORK HOURSPHASE OF WORK: DOGHOUSEREPLACEMENT.HOURS OF TCP: 8AM-5PM24 HR CONTACT:KEVIN HARMONCABLECOM360.322.2805KEVIN.HARMON@CABLECOMLLC.NETJOB NUMBER: JB0002151539JOB ADDRESS: 435 S 51ST CT, RENTON.DESCRIPTION: REPLACE DOGHOUSE ATPROPOSED LOCATION.51SHEET NUMBEROFLEGENDTRAFFIC SAFETY DRUMSTEMP SIGN LOCATIONWORK VEHICLEFLAGGING STATIONWORK AREAR7-T39 NO PARKTRAFFIC CONTROL SUPERVISORES2 0002948/31/2027SPE N CERD.IMEINIRAKSTA TEOFNOTGNIHSAWSPEEDLIMIT255'5'PEDESTRIAN ESCORT: STOP WORK, SECUREPASSABLE ADA COMPLIANT PEDESTRIAN ACCESS ONEXISTING SIDEWALK (4' MIN.). CLEAR ZONE MUST BEFREE OF OVERHEAD HAZARDS WHEN PEDESTRIANSARE MOVING THROUGH THE WORK ZONE.5301401407415421427435441449455501442S 51ST CTTALBOT RD S13'13'26'ROADWORKAHEADW20-1ONE LANEROADAHEADW20-4W20-7X* X * X *50'ROADWORKAHEADW20-1ONE LANEROADAHEADW20-4W20-7X35'X35'X35'50'50'SPOTTER TO ASSISTVEHICLES LEAVINGDRIVEWAYSMFP25003080 SPENCER KARINIEMITRAFFIC CONTROL SUPERVISOR360-722-2852NOTES:1. ALL SIGNS ARE 36"-48" ACROSS2. ASTERISK DENOTES X, L, OR B DISTANCES ARE NOT TO SCALE3. CONTRACTOR SHALL ALWAYS PROVIDE ACCESS TO DRIVEWAYS4. STANDARD ADVANCE WARNING SIGNS SHALL BE USED FOR PLATES OR ROUGH ROAD DURING AFTER-HOURS, INCLUDING "MOTORCYCLIST" SIGN5. FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302. UPO WILL BE REQUIRED IF A TRAFFIC SIGNAL COULD BE COUNTERMANDED6. IF ONLY ONE LANE IS OPEN IN A DIRECTION, THAT LANE SHALL BE A MINIMUM OF 11' WIDE, UNLESS SPOTTER/FLAGGERS ARE USED, IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'7. SIDEWALKS ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OF CURBRURAL ROADS & URBAN ARTERIALSRURAL ROADSRESIDENTIAL & BUSINESS DISTRICTSURBAN STREETSRURAL ROADS & URBAN ARTERIALS350'±500'±100'±200'±(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATEINTERCHANGE RAMPS, AT-GRADE INTERSECTIONS ANDDRIVEWAYS(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TOFIT ROADWAY CONDITIONSSIGN SPACING = X35/40 MPH45/55 MPH25 MPH OR LESS25/30 MPHCHANNELIZATION DEVICESPACING (FEET)35/4525/3050MPHTAPER403020406080TANGENT150251051151253530165180205225245402702953204545049554050500550600101112LANEWIDTH(FEET)MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED (MPH)TRAFFIC CONTROL PLANN O R T H253035404550556065645570495425360305250200155LENGTH (FEET)SPEED (MPH)LONGITUDINAL BUFFER SPACE = BBUFFER DATA20115TYPE OF TCP: WORK HOURSPHASE OF WORK: SPLICE52SHEET NUMBEROFLEGENDTRAFFIC SAFETY DRUMSTEMP SIGN LOCATIONWORK VEHICLETRAFFIC CONTROL SUPERVISORES2 0002948/31/2027SPENCERD.IMEINIRAKSTATEOFNOTGNIHSAW HOURS OF TCP: 8AM-5PM24 HR CONTACT:KEVIN HARMONCABLECOM360.322.2805KEVIN.HARMON@CABLECOMLLC.NETJOB NUMBER: JB0002151539JOB ADDRESS: 4907 TALBOT RD S, RENTONDESCRIPTION: AERIAL SPLICE AT PROPOSEDLOCATION.PEDESTRIAN ESCORT: STOP WORK, SECUREPASSABLE ADA COMPLIANT PEDESTRIAN ACCESS ONEXISTING SIDEWALK (4' MIN.). CLEAR ZONE MUST BEFREE OF OVERHEAD HAZARDS WHEN PEDESTRIANSARE MOVING THROUGH THE WORK ZONE.SPEEDLIMIT35TALBOT RD S5'11'12'11'5'ROADWORKAHEADW20-1W1-4LW4-1BBIKESMERGE WITHTRAFFICX*X*L/2115'X*UTILITY POLESPLICE LOCATION491240047604907ROADWORKAHEADW20-1W20-5CCENTERLANECLOSEDAHEADL/2115'X*X*R3-2R3-216'12'11'MFP25003080 SPENCER KARINIEMITRAFFIC CONTROL SUPERVISOR360-722-2852NOTES:1. ALL SIGNS ARE 36"-48" ACROSS2. ASTERISK DENOTES X, L, OR B DISTANCES ARE NOT TO SCALE3. CONTRACTOR SHALL ALWAYS PROVIDE ACCESS TO DRIVEWAYS4. STANDARD ADVANCE WARNING SIGNS SHALL BE USED FOR PLATES OR ROUGH ROAD DURING AFTER-HOURS, INCLUDING "MOTORCYCLIST" SIGN5. FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302. UPO WILL BE REQUIRED IF A TRAFFIC SIGNAL COULD BE COUNTERMANDED6. IF ONLY ONE LANE IS OPEN IN A DIRECTION, THAT LANE SHALL BE A MINIMUM OF 11' WIDE, UNLESS SPOTTER/FLAGGERS ARE USED, IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'7. SIDEWALKS ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OF CURBRURAL ROADS & URBAN ARTERIALSRURAL ROADSRESIDENTIAL & BUSINESS DISTRICTSURBAN STREETSRURAL ROADS & URBAN ARTERIALS350'±500'±100'±200'±(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATEINTERCHANGE RAMPS, AT-GRADE INTERSECTIONS ANDDRIVEWAYS(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TOFIT ROADWAY CONDITIONSSIGN SPACING = X35/40 MPH45/55 MPH25 MPH OR LESS25/30 MPHCHANNELIZATION DEVICESPACING (FEET)35/4525/3050MPHTAPER403020406080TANGENT150251051151253530165180205225245402702953204545049554050500550600101112LANEWIDTH(FEET)MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED (MPH)TRAFFIC CONTROL PLANN O R T H253035404550556065645570495425360305250200155LENGTH (FEET)SPEED (MPH)LONGITUDINAL BUFFER SPACE = BBUFFER DATA20115TYPE OF TCP: WORK HOURSPHASE OF WORK:MAINTENANCE, SPLICE53SHEET NUMBEROFWORK AREALEGENDTRAFFIC SAFETY DRUMSTEMP SIGN LOCATIONWORK VEHICLETRAFFIC CONTROL SUPERVISORES2 0002948/31/2027SPENCERD.IMEINIRAKSTATEOFNOTGNIHSAW HOURS OF TCP: 8AM-5PM24 HR CONTACT:KEVIN HARMONCABLECOM360.322.2805KEVIN.HARMON@CABLECOMLLC.NETJOB NUMBER: JB0002151539JOB ADDRESS: 4600 TALBOT RD S, RENTONDESCRIPTION: AERIAL SPLICE AT PROPOSEDLOCATION. ACCESS PEDESTAL FORMAINTENANCE.PEDESTRIAN ESCORT: STOP WORK, SECUREPASSABLE ADA COMPLIANT PEDESTRIAN ACCESS ONEXISTING SIDEWALK (4' MIN.). CLEAR ZONE MUST BEFREE OF OVERHEAD HAZARDS WHEN PEDESTRIANSARE MOVING THROUGH THE WORK ZONE.SPEEDLIMIT35UTILITY POLESPLICE LOCATION47605'5'ROADWORKAHEADW20-1W20-5CCENTERLANECLOSEDAHEADL/2115'X*X*ROADWORKAHEADW20-1X*S 48TH CT R3-2R3-2R3-24600R3-25100ROADWORKAHEADW20-1W1-4LW4-1BBIKESMERGE WITHTRAFFICX*X*L/2115'X*5'11'12'11'5'TALBOT RD S32446004635463516'12'11'MFP25003080 SPENCER KARINIEMITRAFFIC CONTROL SUPERVISOR360-722-2852NOTES:1. ALL SIGNS ARE 36"-48" ACROSS2. ASTERISK DENOTES X, L, OR B DISTANCES ARE NOT TO SCALE3. CONTRACTOR SHALL ALWAYS PROVIDE ACCESS TO DRIVEWAYS4. STANDARD ADVANCE WARNING SIGNS SHALL BE USED FOR PLATES OR ROUGH ROAD DURING AFTER-HOURS, INCLUDING "MOTORCYCLIST" SIGN5. FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302. UPO WILL BE REQUIRED IF A TRAFFIC SIGNAL COULD BE COUNTERMANDED6. IF ONLY ONE LANE IS OPEN IN A DIRECTION, THAT LANE SHALL BE A MINIMUM OF 11' WIDE, UNLESS SPOTTER/FLAGGERS ARE USED, IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'7. SIDEWALKS ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OF CURBRURAL ROADS & URBAN ARTERIALSRURAL ROADSRESIDENTIAL & BUSINESS DISTRICTSURBAN STREETSRURAL ROADS & URBAN ARTERIALS350'±500'±100'±200'±(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATEINTERCHANGE RAMPS, AT-GRADE INTERSECTIONS ANDDRIVEWAYS(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TOFIT ROADWAY CONDITIONSSIGN SPACING = X35/40 MPH45/55 MPH25 MPH OR LESS25/30 MPHCHANNELIZATION DEVICESPACING (FEET)35/4525/3050MPHTAPER403020406080TANGENT150251051151253530165180205225245402702953204545049554050500550600101112LANEWIDTH(FEET)MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED (MPH)TRAFFIC CONTROL PLANN O R T H253035404550556065645570495425360305250200155LENGTH (FEET)SPEED (MPH)LONGITUDINAL BUFFER SPACE = BBUFFER DATA20115TYPE OF TCP: WORK HOURSPHASE OF WORK:MAINTENANCE54SHEET NUMBEROFLEGENDTRAFFIC SAFETY DRUMSTEMP SIGN LOCATIONWORK VEHICLEWORK AREATRAFFIC CONTROL SUPERVISORES2 0002948/31/2027SPENCERD.IMEINIRAKSTATEOFNOTGNIHSAW HOURS OF TCP: 8AM-5PM24 HR CONTACT:KEVIN HARMONCABLECOM360.322.2805KEVIN.HARMON@CABLECOMLLC.NETJOB NUMBER: JB0002151539JOB ADDRESS: 4635 MORRIS AVE S, RENTONDESCRIPTION: ACCESS PEDESTAL FORMAINTENANCE.PEDESTRIAN ESCORT: STOP WORK, SECUREPASSABLE ADA COMPLIANT PEDESTRIAN ACCESS ONEXISTING SIDEWALK (4' MIN.). CLEAR ZONE MUST BEFREE OF OVERHEAD HAZARDS WHEN PEDESTRIANSARE MOVING THROUGH THE WORK ZONE.SPEEDLIMIT35TALBOT RD S32446004635463511'12'16'5'5'ROADWORKAHEADW20-1W1-4LW4-1BBIKESMERGE WITHTRAFFICX*X*L/2115'X*ROADWORKAHEADW20-1W20-5CCENTERLANECLOSEDAHEADL/2115'X*X*5'11'12'11'5'R3-2R3-2MFP25003080 SPENCER KARINIEMITRAFFIC CONTROL SUPERVISOR360-722-2852NOTES:1. ALL SIGNS ARE 36"-48" ACROSS2. ASTERISK DENOTES X, L, OR B DISTANCES ARE NOT TO SCALE3. CONTRACTOR SHALL ALWAYS PROVIDE ACCESS TO DRIVEWAYS4. STANDARD ADVANCE WARNING SIGNS SHALL BE USED FOR PLATES OR ROUGH ROAD DURING AFTER-HOURS, INCLUDING "MOTORCYCLIST" SIGN5. FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-95-302. UPO WILL BE REQUIRED IF A TRAFFIC SIGNAL COULD BE COUNTERMANDED6. IF ONLY ONE LANE IS OPEN IN A DIRECTION, THAT LANE SHALL BE A MINIMUM OF 11' WIDE, UNLESS SPOTTER/FLAGGERS ARE USED, IN WHICH CASE THE LANE CAN BE A MINIMUM OF 10'7. SIDEWALKS ARE EITHER OPEN OR NOT OPEN. A SIDEWALK IS CLOSED IF A MINIMUM 4' PATH CANNOT BE MAINTAINED MEASURED FROM PROPERTY LINE, OR 5.5' IF CREATED FROM FACE OF CURBRURAL ROADS & URBAN ARTERIALSRURAL ROADSRESIDENTIAL & BUSINESS DISTRICTSURBAN STREETSRURAL ROADS & URBAN ARTERIALS350'±500'±100'±200'±(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATEINTERCHANGE RAMPS, AT-GRADE INTERSECTIONS ANDDRIVEWAYS(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TOFIT ROADWAY CONDITIONSSIGN SPACING = X35/40 MPH45/55 MPH25 MPH OR LESS25/30 MPHCHANNELIZATION DEVICESPACING (FEET)35/4525/3050MPHTAPER403020406080TANGENT150251051151253530165180205225245402702953204545049554050500550600101112LANEWIDTH(FEET)MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED (MPH)TRAFFIC CONTROL PLANN O R T H253035404550556065645570495425360305250200155LENGTH (FEET)SPEED (MPH)LONGITUDINAL BUFFER SPACE = BBUFFER DATA20115TYPE OF TCP: WORK HOURSPHASE OF WORK:MAINTENANCE55SHEET NUMBEROFLEGENDTRAFFIC SAFETY DRUMSTEMP SIGN LOCATIONWORK VEHICLEWORK AREATRAFFIC CONTROL SUPERVISORES2 0002948/31/2027SPE N CERD.IMEINIRAKSTA TE OFNOTGNIHSAWHOURS OF TCP: 8AM-5PM24 HR CONTACT:KEVIN HARMONCABLECOM360.322.2805KEVIN.HARMON@CABLECOMLLC.NETJOB NUMBER: JB0002151539JOB ADDRESS: 4509 TALBOT RD S, RENTONDESCRIPTION: ACCESS VAULT FORMAINTENANCE.PEDESTRIAN ESCORT: STOP WORK, SECUREPASSABLE ADA COMPLIANT PEDESTRIAN ACCESS ONEXISTING SIDEWALK (4' MIN.). CLEAR ZONE MUST BEFREE OF OVERHEAD HAZARDS WHEN PEDESTRIANSARE MOVING THROUGH THE WORK ZONE.SPEEDLIMIT355'5'45094361443045124550TALBOT RD SS 45TH PL R3-2R3-2ROADWORKAHEADW20-1L/2115'X*X*W20-5CCENTERLANECLOSEDAHEADROADWORKAHEADW20-1W1-4LX*L/2115'X*ROADWORKAHEADW20-1X*11'10'12'11'11'12'10'MFP25003080 © 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS © 2025 TMAP MOBILITY Earthstar Geographics SIO © 2025 TomTom © 2025 Zenrin ADDRESS: 5301 TALBOT RD S, RENTON, WA 98055PROJECT NAME: JB0002151539 - PRINTSDRAWING FILE LOCATION: Z:\SHARED\PROJECTS\CABLECOM\JB0002151539\JB0002151539_ROW\1 - CAD\PRINTS\JB0002151539_PRINTS.DWGSITE LOCATIONSHEET INDEX1 - COVER SHEET2 - GENERAL NOTES3 - LEGEND4/8 - DESIGN VIEW (1/5)9/10 - TYPICALS (1/2)SCOPE OF WORKCONSTRUCTION TO CONSIST OF PLACING NEWCOMCAST AERIAL SPLICE CASES, REPLACEEXISTING COMCAST DOGHOUSE WITH NEWSPH2436 PEDESTAL, ACCESS EXISTING COMCASTPEDESTAL FOR MAINTENANCE, AND ACCESSEXISTING COMCAST VAULT FOR MAINTENANCE ATPROPOSED LOCATIONS.ALL CONSTRUCTION AND RESTORATION TO MEETOR EXCEED CITY OF RENTON STANDARDS.AS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 5301 TALBOT RD S, RENTON, WA 98055PROJECT NUMBER: JB0002151539PERMIT NUMBER: ----CABLECOM ENGINEER: KEVIN HARMONCONFIDENTIAL/ PROPRIETARYSDKQHS06/11/25SDKTPK11/03/25------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.SDKGOR11/10/25BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852101SHEET NUMBEROFKnow what's below.Call before you dig.RVICINITY MAPCONTACTSN O R T HKEVIN HARMONCONSTRUCTION MANAGERCABLECOMKEVIN.HARMON@CABLECOMLLC.NET360.322.2805SPENCER KARINIEMIGENERAL MANAGERBOOKER ENGINEERINGSPENCER@BOOKERENG.COM360.722.2852SHEET 4SHEET 5SHEET 6SHEET 7SHEET 8This permit is for Major construction work in the ROW and will be billed at an additional$158/HR for inspections. After hours and weekend work will be billed at $175/HRMFP25003080RESTORATION PER CITY OF RENTON STANDARDS AS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 5301 TALBOT RD S, RENTON, WA 98055PROJECT NUMBER: JB0002151539PERMIT NUMBER: ----CABLECOM ENGINEER: KEVIN HARMONCONFIDENTIAL/ PROPRIETARYSDKQHS06/11/25SDKTPK11/03/25------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.SDKGOR11/10/25BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852102SHEET NUMBEROFKnow what's below.Call before you dig.RGENERAL NOTESGENERAL NOTES: The locations of utilities shown on these drawing are only approximate. BOOKER ENGINEERING LLC hereby disclaims any responsibility to third parties for theaccuracy of this information. Persons working in the area covered by this drawing must contact the statewide Call-Before-You-Dig System to ascertain the location of underground utilitiesprior to performing any excavation.1. ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORK STANDARDS AND THE STANDARDS ANDSPECIFICATIONS SET FORTH IN THE CITY OF RENTON REGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OREASEMENTS MAY REQUIRE INSPECTED AND APPROVED BY THE RENTON INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BE PROVIDED BYDESIGNEE OF PROJECT SPONSOR/OWNER.2. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ON THESE PLANS, IS BASED ONRECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUESTEXACT FIELD LOCATIONS OF EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITHTHE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THE CONTRACTOR SHALL NOTIFY THERENTON INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IFREQUIRED.4. THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF RENTON AND ALL UTILITY COMPANIES WITH REGARD TO RELOCATIONS ORADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5. THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDS AND SPECIFICATIONS, ANDONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION, TRENCHING, SHORING, TRAFFICCONTROL, AND SECURITY.7. IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, OR OTHER AFFECTED PARTIESWHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.8. ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESS SPECIFICALLY STATED OTHERWISE.9. FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE CITY OF RENTON, THE CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL AND PHASINGPLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTORSHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION APRECONSTRUCTION CONFERENCE SHALL BE HELD WITH THE CITY OF RENTON.10. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THE INTENDED IMPROVEMENTS SHOWNON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11. PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALL CONSTRUCTION DEBRIS AND DIRTTRACKED FROM THE SITE.12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT AT THE CONSTRUCTION SITE ANDAVAILABLE TO THE RENTON INSPECTOR AT ALL TIMES.13. DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATION CONTACT THE ENGINEER FORCLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14. ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY.ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARDSURFACE OR LANDSCAPING.15. ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE CITY OF RENTON ENGINEERING DEPARTMENT STANDARD DETAILS ANDSPECIFICATIONS.16. ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTH MOVING EQUIPMENT,CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE CITY OF RENTON.MFP25003080 AS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 5301 TALBOT RD S, RENTON, WA 98055PROJECT NUMBER: JB0002151539PERMIT NUMBER: ----CABLECOM ENGINEER: KEVIN HARMONCONFIDENTIAL/ PROPRIETARYSDKQHS06/11/25SDKTPK11/03/25------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.SDKGOR11/10/25BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852103SHEET NUMBEROFKnow what's below.Call before you dig.RLEGEND(XXX')N O R T H#F#F#FXXMFP25003080 5414 TALBOT RD SPARCEL# 3123059178401 S 53RD PLPARCEL# 27285000105301 TALBOT RD SPARCEL# 3123059023TALBOT RD SS 53RD PLAS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 5301 TALBOT RD S, RENTON, WA 98055PROJECT NUMBER: JB0002151539PERMIT NUMBER: ----CABLECOM ENGINEER: KEVIN HARMONCONFIDENTIAL/ PROPRIETARYSDKQHS06/11/25SDKTPK11/03/25------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.SDKGOR11/10/25BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852104SHEET NUMBEROFKnow what's below.Call before you dig.R#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION.CONSTRUCTION NOTES1PLACE NEW COMCAST AERIAL SPLICE CASE.PARCEL# 272850TRCTN O R T H 11PHOTO #1: FACING W ON THE E SIDE OF TALBOT RD S1MFP25003080 440 S 51ST CTPARCEL# 8083380000421 S 51ST CTPARCEL# 8083350040427 S 51ST CTPARCEL# 8083350050435 S 51ST CTPARCEL# 8083350060441 S 51ST CTPARCEL# 8083350070449 S 51ST CTPARCEL# 8083350080455 S 51ST CTPARCEL# 8083350090501 S 51ST CTPARCEL# 8083350100S 51ST CTAS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 5301 TALBOT RD S, RENTON, WA 98055PROJECT NUMBER: JB0002151539PERMIT NUMBER: ----CABLECOM ENGINEER: KEVIN HARMONCONFIDENTIAL/ PROPRIETARYSDKQHS06/11/25SDKTPK11/03/25------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.SDKGOR11/10/25BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852105SHEET NUMBEROFKnow what's below.Call before you dig.R#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION.CONSTRUCTION NOTES2REPLACE EXISTING COMCAST DOGHOUSE WITH NEWSPH2436 PEDESTAL.415 S 51ST CTPARCEL# 8083350030N O R T HRESTORATION NOTESARESTORE SOFT SURFACE TO PRIOR TO CONDITION.2A2PHOTO #2: FACING S ON THE S SIDE OF S 51ST CT2AMFP25003080 210 S 50TH STPARCEL# 02905000004907 TALBOT RD SPARCEL# 3123059091 4915 SHATTUCK PL SPARCEL# 1316000000400 S 50TH STPARCEL# 0942900000TALBOT RD SAS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 5301 TALBOT RD S, RENTON, WA 98055PROJECT NUMBER: JB0002151539PERMIT NUMBER: ----CABLECOM ENGINEER: KEVIN HARMONCONFIDENTIAL/ PROPRIETARYSDKQHS06/11/25SDKTPK11/03/25------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.SDKGOR11/10/25BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852106SHEET NUMBEROFKnow what's below.Call before you dig.R#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION.CONSTRUCTION NOTES1PLACE NEW COMCAST AERIAL SPLICE CASE.1N O R T HPHOTO #3: FACING W ON THE W SIDE OF TALBOT RD S13MFP25003080 4635 MORRIS AVE SPARCEL# 8559100000324 S 47TH STPARCEL# 79389000004702 DAVIS AVE SPARCEL# 31230591534915 SHATTUCK PL SPARCEL# 1316000000TALBOT RD SPRIVATE ROADS 47TH STAS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 5301 TALBOT RD S, RENTON, WA 98055PROJECT NUMBER: JB0002151539PERMIT NUMBER: ----CABLECOM ENGINEER: KEVIN HARMONCONFIDENTIAL/ PROPRIETARYSDKQHS06/11/25SDKTPK11/03/25------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.SDKGOR11/10/25BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852107SHEET NUMBEROFKnow what's below.Call before you dig.R#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION.CONSTRUCTION NOTES1PLACE NEW COMCAST AERIAL SPLICE CASE.N O R T H3ACCESS EXISTING COMCAST PEDESTAL FORMAINTENANCE.2UPGRADE EXISTING COMCAST PEDESTAL TO NEW SPH2436PEDESTAL.132PHOTO #4: FACING W ON THE W SIDE OF TALBOT RD SPHOTO #5: FACING W ON THE W SIDE OF TALBOT RD SPHOTO #6: FACING E ON THE E SIDE OF TALBOT RD S1RESTORATION NOTESARESTORE SOFT SURFACE TO PRIOR TO CONDITION.A2A6433MFP25003080 TALBOT RD S4445 TALBOT RD SPARCEL# 31230591264509 TALBOT RD SPARCEL# 3123059061AS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 5301 TALBOT RD S, RENTON, WA 98055PROJECT NUMBER: JB0002151539PERMIT NUMBER: ----CABLECOM ENGINEER: KEVIN HARMONCONFIDENTIAL/ PROPRIETARYSDKQHS06/11/25SDKTPK11/03/25------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.SDKGOR11/10/25BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852108SHEET NUMBEROFKnow what's below.Call before you dig.R#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION.CONSTRUCTION NOTESN O R T H4ACCESS EXISTING COMCAST VAULT FOR MAINTENANCE.4PHOTO #7: FACING W ON THE W SIDE OF TALBOT RD S411MFP25003080 TYPICALSAS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 5301 TALBOT RD S, RENTON, WA 98055PROJECT NUMBER: JB0002151539PERMIT NUMBER: ----CABLECOM ENGINEER: KEVIN HARMONCONFIDENTIAL/ PROPRIETARYSDKQHS06/11/25SDKTPK11/03/25------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.SDKGOR11/10/25BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852109SHEET NUMBEROFKnow what's below.Call before you dig.RMFP25003080 TYPICALSAS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 5301 TALBOT RD S, RENTON, WA 98055PROJECT NUMBER: JB0002151539PERMIT NUMBER: ----CABLECOM ENGINEER: KEVIN HARMONCONFIDENTIAL/ PROPRIETARYSDKQHS06/11/25SDKTPK11/03/25------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.SDKGOR11/10/25BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.28521010SHEET NUMBEROFKnow what's below.Call before you dig.RMFP25003080