Loading...
HomeMy WebLinkAboutJ_Adjustment_parking_location_perimeter_landscaping_251126_v1 Western Washington Division Eastern Washington Division 165 NE Juniper St., Ste 201, Issaquah, WA 98027 407 Swiftwater Blvd., Cle Elum, WA 98922 Phone: (425) 392-0250 Phone: (509) 674-7433 www.EncompassES.net Date: November 26, 2025 To: Jill Ding, Senior Plan From: Encompass Engineering & Surveying Re: Site Plan Review – Adjustment/Modification of zoning requirements Tax Parcel 102305-9086 _____________________________________________________________________________________ Project Description This application proposes to construct a 3-story mixed-use building with below ground parking. The ground floor consists of a commercial use (daycare), staff offices, program space for tenants and a lobby for residents. The upper 2 floors propose 28-dwelling units of varying sizes from 1-3 bedrooms. Vision House is a non-profit organization that provides housing and other family services to mothers and their children in need of transitional housing and support. This proposed building is an expansion of their campus in Renton. Adjustment/Modifications for Site Plan Review This is a request for the city to review a modification to the parking location and perimeter landscaping required by the zoning or design guidelines for development in the CA zone. Vision House Adjustment/Modification Requests 11/26/2025 Page 2 #1: Argument for Departure from Parking Location Requirements Request for modification to surface parking being allowed between the building and front property line based on the fact that this is an internal lot with no public street frontage. Proposed Layout: The new mixed use building is located on a land locked parcel 102305 -9086 with no direct frontage on the public street (Bremerton Ave NE). The new building is located east of parcel 102305-9066 which does have street frontage and provides access drives in to the project site. Both parcels are owned and operated by the Vision House organization and this new building is an extension or new phase of their existing building campus. Parking for the ground floor business is being provided between the new building and the front property line, however, that parking is screened by the existing building to the west and is not visible from the public street. Code requirement: In code section 4-3-100, E2 Parking and Vehicular Access, it says in #1: Parking shall be located so that no surface parking is located between a building and the front property line or a building and the side property line (when a corner lot). #2 says: Parking shall be located so that it is screened from surrounding streets by buildings, landscaping, and/or gateway features as dictated by location. The intent of the Parking and Vehicular Access code is: to provide safe, convenient access; incorporate various modes of transportation, including public transit, in order to reduce traffic volumes and other impacts from vehicles; ensure sufficient parking is provided, while encouraging creativity in reducing the impacts of parking areas; allow an active pedestrian environment by maintaining contiguous street frontages, without parking lot siting along sidewalks and building facades; minimize the visual imp act of parking lots and use access streets and parking to maintain an urban edge to the district. We are requesting a modification from the code requirement to allow parking between the front property line and the building on parcel 102305-9086 for the following reasons: • Due to the new building being located on an internal lot with no street frontage, the front property line is not located on the City ROW. The code does not want parking between the street and the building and that is not being proposed. • The existing building to the west screens the proposed parking, minimizing the visual impact of the parking lot. • The daycare will be located on the ground floor of the building and access to the daycare will be through the front door on the west side of the building. The parking in front of the building provides safe and convenient access from the parent’s vehicles to the pedestrian walkway and directly into the building without having to walk through a parking lot. • Due to the nature of daycare businesses, the parents drop off and pickup will occur mostly in the morning and evening. There are 12 spots proposed at the front of the building, and this should provide convenient parking for quick in and out drop-offs and keep traffic moving through the site without causing any obstructions or impacting the residents or employees as they will be located behind or under the building. It also means that a good portion of the day these parking spots will likely be empty and convenient for people going in and out of the building quickly for short visits. • The remainder of the parking spaces for staff and residents of the mixed-use building will be provided behind the building and in structured parking below the building. This configuration allows us to provide a sufficient amount of parking for all of the uses in the proposed building and provides a higher level of screened parking for vehicles that will be onsite for longer periods of time. We request that modification of the code to allow parking between the building and the front property line be allowed as the intent of the code is still met with the proposed parking layout. We have provided a site plan to illustrate the proposed parking locations. Vision House Adjustment/Modification Requests 11/26/2025 Page 3 #2: Argument for Departure from Perimeter Landscaping Requirements Request for modification to the 10-foot perimeter landscaping required at the eastern property line based on Practical Difficulties and existing conditions. Proposed Layout: The new mixed-use building will be mostly centered on the parcel to allow for ingress/egress around the building and the preservation of the wetland buffer at the south property line and the open space/playground area at the north property line. We are proposing a 5-foot perimeter landscaping buffer at the east property line which is adjacent to another parking lot with approximately 5- feet of perimeter landscaping. In addition to the 5-feet of perimeter landscaping, we are proposing severa l additional landscape islands dispersed through the surface parking on our site, far more area than required in the code. In addition to that, large landscaping pads are proposed at the north and south ends of the building to provide additional green space and further enhance the green area bordering the access drive and pedestrian walkways around the building. Code Requirement: In code section 4-4-070, F6 Parking Lots, it says: Perimeter Landscaping-All parking lots shall have perimeter landscaping. See subsection H4 of this section, Perimeter Parking Lot Landscaping. H4 says: Such landscaping shall be at least ten feet in width as measured from the street right of way. We are requesting a reduction of the perimeter landscaping requirement from 10 feet to 5 feet with the understanding that we will propose additional interior parking lot landscaping in lieu of the 5 -foot shortage of perimeter landscaping. The following information explains the reasoning for our request and the alternatives we propose to counter the impact of less perimeter landscaping. Reasons for reduction: • The perimeter of this parking lot is not adjacent to a street as it abuts another parking lot for a commercial site, so we are not screening the parking from the street frontage and pedestrians, which appears to be the intent of the code. • The neighboring parcel parking lot has also provided some landscaping at their perimeter lot line which appears to be about 5 feet. In essence the perimeter landscaping from both parcels combined will provide 10-feet of perimeter landscaping. • We are providing a 2-way access road around the building that has a 24-foot width in front of all perpendicular parking. This provides greater mobility around the site for all types of vehicles and easy access parking along the east property line. It also keeps a consistent design layout to the earlier phases of the Vision House campus. Our original design had a 20-foot road access road as required by fire, but we increased it to 24-feet to meet the requirements of 2-way traffic and perpendicular parking. • We had to increase the access road width to 24-feet wide on the west side of the new building to meet the 2-way traffic and perpendicular parking that is existing and proposed. This further compressed the available width on the lot to fit the building and required parking spaces. • The building design has been maximized to provide as many units as possible so that Vision House can make the most of this investment into the community. Reducing the width of the building to provide 5 more feet of perimeter landscaping would be to the detriment of the project. Proposed Alternatives: • The project is to provide 31 surface parking stalls. The requirement for interior parking lot landscaping is 15/sf per parking space. That means we are required to provide 4 65sf of interior parking lot landscaping. We have proposed three 9’x20’ parking islands between parking spots 13-31 which adds up to 540sf of landscaping. There are also two 9’x16’ landscape islands provided between spots 1-12 which adds up to 288sf of landscaping. This exceeds the required interior landscaping requirement by 363sf. Vision House Adjustment/Modification Requests 11/26/2025 Page 4 • In addition to the landscape islands dispersed through the parking spots, we have proposed additional landscaping in front of the wetland buffer in the SE corner of the parcel which will be 2,790 SF. • At the north end of the building, we have proposed 1,297 SF of landscaping that wraps from the edge parking spot 1 to the NE corner of the building. This provides a nice buffer of landscaping between the building and the access road. • At the South end of the building there is an even larger landscaping pad of 2,356 SF that provides a nice buffer from the access road. We could have proposed additional parking there but would prefer to add the green space where we can. We request a reduction of the code requirement from a 10-foot perimeter landscaping requirement down to 5-feet so that we can maintain the existing building design, maintain a 24-foot drive aisle around the site for greater accessibility and perpendicular parking on the east property line. We believe that between our parking lot and the neighboring site to the east there will still be approximately a combined 10 -feet of landscaping between the sites which would meet the requirement. We also feel that the co de intent of 10- feet of perimeter landscaping was to provide a buffer of green space between parking lots and the street ROW way, but this is an interior building lot with no street frontage, so the requirement is unwarranted. We also believe the additional interior parking lot landscaping and landscaping blocks bordering the access drive are a much more beneficial alternative to the perimeter landscaping requirement. Please review our attached site plan which demonstrates the additional proposed interior landscaping and the limitations of the lot width. IN COMPLIANCE WITH CITY OF RENTON STANDARDS Know what's Call below. before you dig. R Encompass Eastern Washington Division 407 Swiftwater Blvd. ▪ Cle Elum, WA 98922 ▪ Phone: (509) 674-7433 Western Washington Division 165 NE Juniper Street, Suite 201 ▪ Issaquah, WA 98027 ▪ Phone: (425) 392-0250 ENGINEERING & SURVEYING XX X X X X X X BR E M E R T O N A V E N E 1 BR E M E R T O N A V E N E COVER SHEET, SITE & HORIZONTAL CONTROL PLAN VISION HOUSE VISION HOUSE PHASE IV BREMERTON AVE NE PROJECT TEAM: SITE DATA: LEGAL DESCRIPTION:INSTRUMENTATION: BENCHMARK: VERTICAL DATUM: BASIS OF BEARINGS: HORIZONTAL DATUM: UTILITY DISTRICT INFORMATION: CONTRACTOR RESPONSIBILITY: DISCREPANCIES: EXISTING UTILITY NOTE: EARTHWORK QUANTITIES: FIRE SPRINKLER NOTE: VICINITY MAP PARKING NOTE: NORTH CONTRACTOR NOTES: SETBACKS: PARKING REQUIREMENTS: PARKING PROPOSED DESCRIPTION SPOTS QTY ON-SITE PROPOSED IMPERVIOUS SURFACE: ON-SITE PROPOSED LANDSCAPE: OFF-SITE PROPOSED IMPERVIOUS SURFACE:SHEET INDEX NO.NAME 1 COVER SHEET, SITE & HORIZONTAL CONTROL PLAN 2 SURFACE WATER NOTES 3 WATER & SEWER NOTES 4 TOPOGRAPHIC SURVEY 5 DEMOLITION & TESC PLAN 6 TESC DETAILS 7 OVERALL GRADING PLAN 8 GRADING DETAILS I 9 GRADING DETAILS II 10 OVERALL DRAINAGE PLAN 11 VAULT PLAN 12 GRADING & DRAINAGE PROFILE 13 OVERALL SEWER PLAN 14 OVERALL WATER PLAN 15 SIGNAGE, MAILBOX & CHANNELIZATION PLAN 16 TREE RETENTION-LAND CLEARING (TREE INVENTORY) PLAN NO P A R K I N G F I R E L A N E NO P A R K I N G F I R E L A N E NO P A R K I N G F I R E L A N E N O P A RKING FIRE LANE NO P A R K I N G F I R E L A N E NO P A R K I N G F I R E L A N E NO P A R K I N G F I R E L A N E NO P A R K I N G F I R E L A N E IN COMPLIANCE WITH CITY OF RENTON STANDARDS Know what's Call below. before you dig. R Encompass Eastern Washington Division 407 Swiftwater Blvd. ▪ Cle Elum, WA 98922 ▪ Phone: (509) 674-7433 Western Washington Division 165 NE Juniper Street, Suite 201 ▪ Issaquah, WA 98027 ▪ Phone: (425) 392-0250 ENGINEERING & SURVEYING XX X X X X X X BR E M E R T O N A V E N E 15 BR E M E R T O N A V E N E SIGNAGE, MAILBOX & CHANNELIZATION PLAN VISION HOUSE VISION HOUSE PHASE IV BREMERTON AVE NE NORTH UP UP B B C C D D E E F F G G 2 2 3 3 4 4 H H A A 5 5 1 1 20'-7"30'-0"30'-0"30'-0"30'-0"30'-0"11'-9" 182'-4" 23 ' - 5 " 19 ' - 1 0 " 28 ' - 9 " 18 ' - 1 " 90 ' - 1 " 23 ' - 5 " 19 ' - 1 0 " 28 ' - 9 " 18 ' - 1 " 90 ' - 1 " 20'-7"30'-0"30'-0"30'-0"30'-0"30'-0"11'-9" 182'-4" 9' - 0 " X 2 0 ' - 0 " 9 ' - 0 " X 2 0 ' - 0 " 9 ' - 0 " X 2 0 ' - 0 " 9 ' - 0 " X 2 0' - 0 " 9 ' - 0 " X 2 0 ' - 0 " 9 ' - 0 " X 2 0 ' - 0 " 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9' - 0 " X 1 6 ' - 0 " 9 ' - 0 " X 1 6 ' - 0 " 9 ' - 0 " X 1 6 ' - 0 " 9 ' - 0 " X 1 6' - 0 " 9 ' - 0 " X 1 6 ' - 0 " 9'-0" X 20'-0"9'-0" X 20'-0"9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" 9'-0" X 20'-0" A-2A 1 A-2B 1 A-2A2 A-2B 2 8'-0" X 20'-0"9'-0" X 20'-0" VAN ACCESIBLE 2 A-9 1 A-9 BASEMENT PARKING LEVEL STAIR 1 ELEV. EQUIP. STAIR 2 HOT WATER ROOM MAIN ELECTRICAL ROOM TRASH ACCESS DRIVE AISLE 24'-0" MIN. DRIVE AISLE 24'-0" MIN. DR I V E A I S L E 24 ' - 0 " M I N . SI D E W A L K SI D E W A L K 6'-0" FI R E SP R I N K L E R RO O M STORAGE BICYCLE ROOM HB ELEV. A.1 A.1 B.1 B.1 B.2 B.2 C.1 C.1 D.1 D.1 E.2 E.2 F.1 F.1 F.2 F.2 G.1 G.1 0.1 0.1 2.1 2.1 3.1 3.1 3.2 3.2 5.1 5.1 2.2 2.2 STORAGE ROOM COM. S P1 RES. S EV P28 RES. S EV-C P29 COM. S P2 COM. S P3 RES. S P4 RES. S P5 RES. S P6 RES. S P8 RES. S P7 RES. S P10 RES. S P9 RES. S EV-R P11 RES. S P13 RES. S EV-R P12 RES. S EV-R P14 RES. S P16 RES. S EV-R P15 RES. S EV-R P17 RES. S P19 RES. S EV-R P18 RES. EV P21 RES. C P20 RES. C EV-R P23 RES. EV P22 RES. C P24 RES. S EV-C P30 RES. S EV-C P31 RES. S EV-C P33 RES. S EV-C P32 RES. S EV-C P34 RES. S EV-C P35 PROJECT ADA EV P27 PROJECT ADA P26 PROJECT ADA V P25 18 SECURE BIKE SPOTS (2' X 6') 6' - 0 " 2'-0" 1 4 8 16 SCALE: 1/8" = 1'-0" JOB NO. DATE 10900 NE 8th Street, Suite 1650 Bellevue, Washington 98004 425-453-5388 OVERALL BUILDING PLAN -BASEMENT/PARKING LEVEL VISION HOUSE CHILDREN'S VILLAGE PHASE IV 1779-001 11/20/25 A-4BREMERTON AVE NE, RENTON WA 98059 1/8" = 1'-0" 1 PLANNING FLOOR PLAN - PARKING TR U E NO R T H AREA SCHEDULE - GROSS BUILDING AREAS PARKING NAME LEVEL AREA CONDITIONED T.O. SLAB PARKING 680 SF NON-CONDITIONED T.O. SLAB PARKING 15,369 SF 16,049 SF Df Df Df Df W Df Df W W W W WW W W W Df Df Df Df Df Df Df W W W W W WWAZ AZ AZ AZ AZ AZ AZ AZ AZ Eg Eg Eg Eg RH RH N N N N La La La MG MG MG DV DV DV DV DV DV FG FG FG Df Full and Matching Full and Matching Full and Matching Full and Matching Full and Matching Full and Matching Full and Matching Full and Matching Full and Matching/Plant 30" o.c. Viburnum davidii* Nandina domestica* Azalea sp. 'Hino Crimson'* Miscanthus sinensis* Pennisetum alop. 'Hameln'* Euonymus fortunei 'Emerald n Gold'* Lavandula sp.* Rhododendron 'Purple Splendour'* Arctostaphyllos uva-ursi* David Viburnum Nandina Evergreen Azalea Maiden Grass Ft Grass Euonymus Lavender Rhodie Kinnikinnik 2 gallon 2 gallon 2 gallon 2 gallon 2 gallon 2 gallon 2 gallon 2 gallon 1 gallonAs req'd DV La *Considered drought tolerant in Pacific Northwest once established RH N FG AZ SHRUBS and GROUND COVER Eg BOTANICAL NAME COMMON NAME QTY SIZE REMARKS PLANT SCHEDULE Lawn Full and Matching/Plant 30" o.c.Gaultheria shallon*Salal 1 gallonAs req'd BOTANICAL NAME Pseudotsuga menziesii Thuja plicata Little Leaf Linden 'Chancellor' Zelkova serrata 'Green Vase' Ulmus 'Frontier' Styrax japonicus 'Snowcone' 26 34 8 3 8 0.5 79.5 W REPLACEMENT TREES QTY TREE CREDITS TREES 13 17 4 3 8 2 TREE SIZE 'Large' 'Large' 'Large' 'Medium' 'Medium' 'Small' CREDIT PER TREE 2 2 2 1 1 0.25 MG IN COMPLIANCE WITH CITY OF RENTON STANDARDS JEFF VARLEY landscape architect 19819 30th Dr SE Bothell Washington 98012 email varley_jeff@hotmail.com phone 425-466-9430 www.varleylandscape.com VARLEY VARLEY VARLEY 4 0 NORTH 1" = 20'-0"SHEET SIZE 22" x 34" LANDSCAPE PLAN L-1 802040 TR-1 TR-2 TREE DRIPLINE TREE PROTECTION FENCEPROPERTY BOUNDARY PROPERTY BOUNDARY PROPERTY BOUNDARYBUILDING SETBACK FROM CRITICAL AREA CRITICAL AREA BUFFER CRITICAL AREA EXISTING PLAY AREA NO TREE DUE TO UNDERGROUND STORM VAULT