Loading...
HomeMy WebLinkAbout2525 Edmonds_Sewer Main Plans_APPROVEDDATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR FILEN AM E : SURVEYED: VERTICAL: NAVD 1988 IF NOT ONE INCH ONE INCH AT FULL SCALE HORIZONTAL: NAD 1983/1991 SCALE ACCORDINGLY DATUM Planning/Building/Public Works Dept. CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS SHEET NO. SHEET NO. SHEET NO. SHEET NO. SHEET NO. SHEET NO. SHEET NO. TITLESHEET NO. SCALE IN FEET 0 120 PROPOSED PROJECT AREA C-1.0 LEGAL DESCRIPTION R-8 3343900078 CITY OF RENTON RENTON, WA 98056 2525 EDMONDS AVE NE PHONE: 425-2984412 SAMMAMISH WA 98074 21923 NE 11TH ST SITE SURVEY INC PROJECT ENGINEER: SURVEYOR PARCEL ACREAGE: JURISDICTION: TAX PARCEL NUMBER: ZONING: 'PROJECT SITE: PROPERTY OWNER: VICINITY MAP SCOPE OF WORKS 1 10 7/10/2025 03/26/2023 PHONE: 206-795-5674 BOTHELL, WA 98011 8822 NE 178TH ST TANDEM ENGINEERING CONSULTANT LLC 8,067 S.F. (0.185 ACRES) AS SURVEYED ZHIFENG LIANG 60 30 60 E D M O N D S AV E N E D AYT O N AV E N E NE 25TH ST NE 25TH ST 3343900078 CONTRACTOR SHALL CONFIRM EARTHWORK VOLUMES TO THEIR SATISFACTION. QUANTITIES ARE FOR REFERENCE ONLY. EARTHWORK QUANTITIES STIE DISTURBACE AREA: 6,500 S.F CONSTRUCT A 115-FOOT SEWER MAIN WITH AN 8-INCH DIAMETER ON THE PRIVATE ACCESS ROAD BACK FILL : 138 CUBIC YARD FOR SEWER MAIN INSTALLATION EXCAVATION: 140. CUBIC YARD FOR SEWER MAIN INSTALLATION. SITE INFORMATION SEWER DETAILS SEWER NOTES TESC DETAILS SEWER MAIN PLAN GENERAL NOTES EXISTING SURVEY COVER SHEET ABBREVIATIONS W S E N IE ELE. D.I. CB CONC CDF SSCO STD. COR WEST SOUTH EAST NORTH INVERT ELEVATION ELEVATION DUCTILE IRON PIPE CATCH BASIN CONCRETE CONTROL DENSITY FILL SIDE SEWER CLEANOUT STANDARD CITY OF RENTON STA. CL. MIN. FL MJ NTS DIAM. PVC STATION CLASS MINIMUM FLANGE MECHANICAL JOINT NON TO SCALE DIAMETER POLYVINY CHLORIDE 2525 RESIDENT SEWER PLAN COVER SHEET 2525 RESIDENT SEWER PLAN W W P - 2 7 - 4 3 5 3 THAT PORTION OF THE NORTH HALF OF TRACT 205 OF C.D. HILLMANS LAKE WASHINGTON GARDEN OF EDEN DIVISION NO. 4, ACCORDING TO THE PLAT RECORDED IN VOLUME 11, OF PLATS, PAGE 82, IN KING COUNTY, WASHINGTON DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHEAST CORNER OF SAID TRACT 205; THENCE S 0 33/64 31'03" W ALONG THE EAST LINE OF SAID TRACT A DISTANCE OF 65.00 FEET; THENCE N 88 33/64 58'56" W PARALLEL TO THE NORTH LINE OF SAID TRACT A DISTANCE OF 113.00 FEET TO A POINT ON A CURVE THE CENTER OF WHICH BEARS S 61 33/64 35'51" W; THENCE ALONG SAID CURVE TO THE LEFT WITH A RADIUS OF 30.00 FEET, FOR A DISTANCE OF 76.28 FEET TO A POINT WHICH BEARS N 84 33/64 04'34" W FROM THE CENTER OF SAID CURVE, SAID POINT BEING THE TRUE POINT OF BEGINNING OF THE PARCEL HEREINAFTER DESCRIBED; THENCE N 84 33/64 04'34" W, A DISTANCE OF 83.85 FEET TO THE WEST LINE OF SAID TRACT 205; THENCE S 0 33/64 30'55" W ALONG SAID WEST LINE, A DISTANCE OF 129.48 FEET TO A POINT 100.00 FEET NORTH OF THE SOUTHWEST CORNER OF THE NORTH HALF OF SAID TRACT 205; THENCE S 89 33/64 55'54" E PARALLEL TO THE SOUTH LINE OF SAID NORTH HALF A DISTANCE OF 20.00 FEET; THENCE N 38 33/64 43'17" E, A DISTANCE OF 120.91 FEET TO A POINT ON SAID CURVE; THE CENTER OF WHICH BEARS N 38 33/64 43'17" E; THENCE ALONG SAID CURVE TO THE RIGHT WITH A RADIUS OF 30.00 FEET FOR A DISTANCE OF 29.95 FEET TO THE TRUE POINT OF BEGINNING; TOGETHER WITH AN UNDIVIDED 1/3 INTEREST AND TOGETHER WITH AN EASEMENT FOR INGRESS AND EGRESS OVER THE REMAINING 2/3 INTEREST IN THAT PORTION OF THE NORTH HALF OF TRACT 205 OF C. D. HILLMANS LAKE WASHINGTON GARDEN OF EDEN DIVISION NO. 4, AND TOGETHER WITH VACATED COUNTY ROAD NO. 174, ACCORDING TO THE PLAT RECORDED IN VOLUME 11, OF PLATS, PAGE 82, IN KING COUNTY, WASHINGTON DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHEAST CORNER OF SAID TRACT; THENCE S 0 33/64 31'03" W, ALONG THE EAST LINE OF SAID TRACT A DISTANCE OF 65.00 FEET TO THE TRUE POINT OF BEGINNING OF PARCEL HEREINAFTER DESCRIBED; THENCE N 88 33/64 58'56" W PARALLEL WITH THE NORTH LINE OF SAID TRACT A DISTANCE OF 113.00 FEET TO A POINT ON A CURVE, THE CENTER OF WHICH BEARS S 61 33/64 35'51" W; THENCE ALONG SAID CURVE TO THE LEFT WITH A RADIUS OF 30.00 FEET FOR A DISTANCE OF 166.68 FEET TO A POINT WHICH BEARS S 76 33/64 44'01" E FROM THE CENTER OF SAID CURVE; THENCE S89 33/64 55'54 E PARALLEL TO THE SOUTH LINE OF THE NORTH HALF OF SAID TRACT 205, A DISTANCE OF 110.00 FEET TO THE EAST LINE OF SAID TRACT; THENCE N 0 33/64 31'03" E ALONG SAID EAST LINE A DISTANCE OF 19.29 FEET TO THE TRUE POINT OF BEGINNING; SITUATE IN THE CITY OF RENTON, COUNTY OF KING, STATE OF WASHINGTON. S-435301 C 2 5 0 0 1 3 8 2 C8.0-C10.0 C 7.0 C 5.0-C6.0 C 4.0 C 3.0 C 2.0 C 1.0 DEVELOPMENT ENGINEERING HBray 12/08/2025 WASTEWATER UTILITY jstowell 12/09/2025 REGIONAL FIRE AUTHORITY cthomas 12/10/2025 APPROVED FOUND MONUMENT IN CASE 22.0' 24.1' 4.1' 4.1' 13.6' 18.7' 24.3' 54.2'315.1319.0323.2315.9315.8315.9315.7315.0315.5315.6315.5315.9315.5315.0314.9315.1315.0315.1315.4315.7315.6315.6315.6315.8315.3315.2315.2315.5315.6315.7315.5315.0315.0315.1315.5315.0315.6316.4317.1317.3318.3317.1318.3317.6317.6316.6317.1316.0318.2315.6318.1318.6315.9316.4318.3318.1318.2318.3318.3318.7318.8317.3318.3318.5317.3317.5317.6317.7318.1318.1318.6319.3319.7319.7319.7319.5319.4319.6319.4319.3319.3319.1318.9319.2319.5319.6319.7319.9320.2319.6321.6321.4321.3321.2321.4321.0321.0320.8321.0321.6321.5321.2320.7319.4 318.0318.3DS6*317.9DS6*31 7.9319.6318.5321.3318.4318.9319.2319.5320.7 320.4320.7320.7320.4320.9320.4321.0DF36321.5321.2321.7DF6320.2322.7DF10322.4322.7323.9324.9DS16323.3322.5322.7323.9324.2323.7322.2322.1323.8324.8325.1324.2322.7322.4322.4322.4321.5321.4321.5321.6321.6321.7321.3321.3321.3320.7321.2321.3320.9321.9319.7318.1 320 .9321.2319.0EVLTP R=30.00' A=166.67'D=318°18'35" R=30.00' A=60.44'D=115°25'40" R=30.00'A=76.28' D=145°41'03" S38°42'18"W 30.00' S84°05'50"E30.00' S 6 1 °3 5 '1 3 "W 3 0 .0 0' N88°59'34"W 110.00'S0°30'25"W 19.29' S0°30'25"W 286.68' S0°30'25"W 65.00' S84°05'12"E 83.85' N0 °30'17"E 129.48' N89°56'32"W 20.00' N38°42'39"E 120.93' R=30.00' A=29.95' D= 57°11'52" ONE STORY HOUSE 16.5' 26.0' 27.3' 6.9' 5.1' 29 .6' S HE D 2.0' SE SH ED 0.6' S E SHED R O OF 0.1' N W R O OF 1.1' N W 1.3' N W 3.0' 0.3' N 0.9' W 0.1' E 0.4' W 0.5' W 0.5' N 1.1' N 1.9' 3.5' 0.7' SE 0.6' SE 0.1' N W 1.0' N W RH = 334.6' FF = 322.7' FF = 322.6' FF = 321.4' HEDGE SET REBAR & CAP (38964) OFFSET 2.00' N SET REBAR & CAP (38964) SET REBAR & CAP (38964) SET REBAR & CAP (38964) FENCE 0.8' N & 1.0' W FENCE 0.2' S & 1.3' W ED MOND S AVE N UE NE CB RIM = 314.98' SDMH RIM = 315.54' IE (N) = 309.44' IE (S) = 309.59' SSMH RIM = 315.69' IE (N,S,W) CTR. CHN. = 309.92' CB RIM = 315.01' IE (W) 12" RCP = 313.19' S89°56'32"E 113.00'506.09' PA R C E L N O. 3 3 4 3 9 0 -0078 PA R C E L N O. 3 3 4 3 9 0 -0077 PA R C E L N O. 3 3 4 3 9 0 -0079 PA R C E L N O. 2 7 2 0 0 0 -0080 PA R C E L N O. 3 3 4 3 9 0 -0080 PA R C E L N O. 3 3 4 3 9 0 -0094 PA R C E L N O. 3 3 4 3 9 0 -0078 PA R C E L N O. 3 3 4 3 9 0 -0091 PA R C E L N O. 2 7 2 0 0 0 -0090 PA R C E L N O. 2 7 2 0 0 0 -0100 FF = 321.5' SET REBAR & CAP (38964) OFFSET 1.00' NE 324 3 2 2 322 324 320 3 18 3 1 8 316 318 318 318 GARAGE FF = 320.9' GARAGE FF = 317.6' INGRESS, EGRESS & UTILITIES EASEMENT NO AS-BUILT/RECORD DRAWING FOR EXISTING SEPTIC SYSTEM AVAILABLE FOUND MONUMENT IN CASE COR #1837 FOUND MONUMENT IN CASE COR #0794 N88°59'34"W 30.00' NE CORNER OF TRACT 205 SET 5/8" X 24" IRON ROD W/1" YELLOW PLASTIC CAP POWER METER GAS METER P CATCH BASIN STORM DRAIN MANHOLE SANITARY SEWER CLEANOUT MAILBOX SANITARY SEWER MANHOLE WATER VALVE FIRE HYDRANT WATER METER ELECTRICAL VAULT UTILITY HANDHOLE EVLT CABLE PEDESTAL GAS VALVE SS SD APPROXIMATE LOCATION SANITARY SEWER LINE APPROXIMATE LOCATION STORM DRAIN LINE UGE W G APPROXIMATE LOCATION UNDERGROUND GAS LINE APPROXIMATE LOCATION UNDERGROUND WATER LINE APPROXIMATE LOCATION UNDERGROUND POWER LINE UTILITY POLE OHP OVERHEAD POWER WOOD FENCE TIMBER WALL CONCRETE WALL ROCKERY ASPHALT SURFACE CONCRETE SURFACE GRAVEL SURFACE DF DS DOUGLAS FIR DECIDUOUS * INDICATES MULTI-TRUNK UGC APPROXIMATE LOCATION UNDERGROUND CABLE LINE GENERAL NOTES DATUM VERTICAL DATUM & CONTOUR INTERVAL Phone: 425.298.4412 BASIS OF BEARINGS www.sitesurveymapping.com DRNDATEREVISION A BEARING OF S0°30'25"W FOR THE CENTERLINE OF EDMONDS AVENUE NE BASED ON FOUND MONUMENTS. NE 1/4, NE 1/4, SEC 05, TWP 23N, RNG 5E, W.M. Site Surveying, Inc. 21923 NE 11th Street Sammamish, WA 98074 1. THIS SURVEY WAS COMPLETED WITHOUT BENEFIT OF A CURRENT TITLE REPORT. EASEMENTS AND OTHER ENCUMBRANCES MAY EXIST ON THIS PROPERTY THAT ARE NOT SHOWN HEREON. 2. INSTRUMENTATION FOR THIS SURVEY WAS A 3-SECOND SPECTRAPRECISION FOCUS 35 TOTAL STATION AND AN EMLID REACH RS2 GPS RECEIVER. PROCEDURES USED IN THIS SURVEY MEET OR EXCEED STANDARDS SET BY WAC 332-130-090. 3. THE INFORMATION ON THIS MAP REPRESENTS THE RESULTS OF A SURVEY MADE IN JANUARY 2025 AND CAN ONLY BE CONSIDERED AS INDICATING THE GENERAL CONDITIONS EXISTING AT THAT TIME. 4. UTILITIES SHOWN ON THIS SURVEY ARE BASED UPON ABOVE GROUND OBSERVATIONS AND AS-BUILT PLANS WHERE AVAILABLE. ACTUAL LOCATIONS OF UNDERGROUND UTILITIES MAY VARY AND UTILITIES NOT SHOWN ON THIS SURVEY MAY EXIST ON THIS SITE. 5. ALL MONUMENTS WERE LOCATED DURING THIS SURVEY UNLESS OTHERWISE NOTED. ELEVATIONS SHOWN ON THIS DRAWING WERE DERIVED FROM GPS OBSERVATION USING THE WSRN. DATUM - NAVD 88 2.0' CONTOUR INTERVAL - THE EXPECTED VERTICAL ACCURACY IS EQUAL TO 1/2 THE CONTOUR INTERVAL OR PLUS / MINUS 1.0' FOR THIS PROJECT. LEGAL DESCRIPTION PROJECT INFORMATION LEGEND C PROJECT NO.24-684 DRAWN BY: MTS CHECKED BY: TNW DATE: 1/7/25 SHEET 1 OF 1 THAT PORTION OF THE NORTH HALF OF TRACT 205 OF C.D. HILLMANS LAKE WASHINGTON GARDEN OF EDEN DIVISION NO. 4, ACCORDING TO THE PLAT RECORDED IN VOLUME 11, OF PLATS, PAGE 82, IN KING COUNTY, WASHINGTON DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHEAST CORNER OF SAID TRACT 205; THENCE S 0°31'03" W ALONG THE EAST LINE OF SAID TRACT A DISTANCE OF 65.00 FEET; THENCE N 88°58'56" W PARALLEL TO THE NORTH LINE OF SAID TRACT A DISTANCE OF 113.00 FEET TO A POINT ON A CURVE THE CENTER OF WHICH BEARS S 61°35'51" W; THENCE ALONG SAID CURVE TO THE LEFT WITH A RADIUS OF 30.00 FEET, FOR A DISTANCE OF 76.28 FEET TO A POINT WHICH BEARS N 84°04'34" W FROM THE CENTER OF SAID CURVE, SAID POINT BEING THE TRUE POINT OF BEGINNING OF THE PARCEL HEREINAFTER DESCRIBED; THENCE N 84°04'34" W, A DISTANCE OF 83.85 FEET TO THE WEST LINE OF SAID TRACT 205; THENCE S 0°30'55" W ALONG SAID WEST LINE, A DISTANCE OF 129.48 FEET TO A POINT 100.00 FEET NORTH OF THE SOUTHWEST CORNER OF THE NORTH HALF OF SAID TRACT 205; THENCE S 89°55'54" E PARALLEL TO THE SOUTH LINE OF SAID NORTH HALF A DISTANCE OF 20.00 FEET; THENCE N 38°43'17" E, A DISTANCE OF 120.91 FEET TO A POINT ON SAID CURVE; THE CENTER OF WHICH BEARS N 38°43'17" E; THENCE ALONG SAID CURVE TO THE RIGHT WITH A RADIUS OF 30.00 FEET FOR A DISTANCE OF 29.95 FEET TO THE TRUE POINT OF BEGINNING; TOGETHER WITH AN UNDIVIDED 13 INTEREST AND TOGETHER WITH AN EASEMENT FOR INGRESS AND EGRESS OVER THE REMAINING 23 INTEREST IN THAT PORTION OF THE NORTH HALF OF TRACT 205 OF C. D. HILLMANS LAKE WASHINGTON GARDEN OF EDEN DIVISION NO. 4, AND TOGETHER WITH VACATED COUNTY ROAD NO. 174, ACCORDING TO THE PLAT RECORDED IN VOLUME 11, OF PLATS, PAGE 82, IN KING COUNTY, WASHINGTON DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHEAST CORNER OF SAID TRACT; THENCE S 0°31'03" W, ALONG THE EAST LINE OF SAID TRACT A DISTANCE OF 65.00 FEET TO THE TRUE POINT OF BEGINNING OF PARCEL HEREINAFTER DESCRIBED; THENCE N 88°58'56" W PARALLEL WITH THE NORTH LINE OF SAID TRACT A DISTANCE OF 113.00 FEET TO A POINT ON A CURVE, THE CENTER OF WHICH BEARS S 61°35'51" W; THENCE ALONG SAID CURVE TO THE LEFT WITH A RADIUS OF 30.00 FEET FOR A DISTANCE OF 166.68 FEET TO A POINT WHICH BEARS S 76° 44'01" E FROM THE CENTER OF SAID CURVE; THENCE S89°55'54 E PARALLEL TO THE SOUTH LINE OF THE NORTH HALF OF SAID TRACT 205, A DISTANCE OF 110.00 FEET TO THE EAST LINE OF SAID TRACT; THENCE N 0°31'03" E ALONG SAID EAST LINE A DISTANCE OF 19.29 FEET TO THE TRUE POINT OF BEGINNING; SITUATE IN THE CITY OF RENTON, COUNTY OF KING, STATE OF WASHINGTON. PROPERTY OWNER: TAX PARCEL NUMBER: PROJECT ADDRESS: ZONING: JURISDICTION: PARCEL ACREAGE: ZHIFENG LIANG 2525 EDMONDS AVENUE NE RENTON, WA 98056 334390-0078 2525 EDMONDS AVENUE NE RENTON, WA 98056 R-8 CITY OF RENTON 8,067 S.F. (0.185 ACRES) AS SURVEYED ZHIFENG LIANG 2525 EDMONDS AVENUE NE RENTON, WA 98056 2025, SITE SURVEYING, INC., ALL RIGHTS RESERVED TOPOGRAPHIC SURVEY MTS6/10/25 UNDERGROUND UTILITIES MTS7/9/25 COR MON, SEWER IE S-435302 C2 5 0 0 1 8 2 WW P - 2 7 - 4 3 5 3 DEVELOPMENT ENGINEERING HBray 12/08/2025 DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR FILEN AM E : SURVEYED: VERTICAL: NAVD 1988 IF NOT ONE INCH ONE INCH AT FULL SCALE HORIZONTAL: NAD 1983/1991 SCALE ACCORDINGLY DATUM Planning/Building/Public Works Dept. CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS C-3.0 3 10 PR21-000214 B24001658 v1 GENERAL NOTES 2525 RESIDENT SEWER PLAN ROAD RIGHTS-OF-WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS-OF-WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS 22. WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST. DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM, ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON-SITE BMPS SHALL BE RESTORED TO THEIR FULLY PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT-LADEN WATER FROM LEAVING THE PROJECT SITE, 21. AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW. SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR 20. ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION. AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING STORMWATER FACILITIES OR ON-SITE BMPS (AMENDED SOILS, BIORETENTION, PERMEABLE PAVEMENT, 19. TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL 18. CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT-LADEN WATER INTO THE DOWNSTREAM SYSTEM. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE 17. CONDITION. TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM 16. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY. THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. 15. ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS.14. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY.13. ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST 12. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL.11. CHANNELS, OR STORMWATER FACILITIES. APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, 10. REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION 9. ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY8. MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT. CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON-SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION, SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON-SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF 7. WASHOUT AREAS. TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES. ON-SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF-SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE 6. WATERS OF THE STATE. BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING CLEAN AND TRACK-OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. 5. CONSTRUCTION. BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS 4. COMMENCEMENT TO POST-PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION 3. ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT. PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL 2. REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE-CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY 1. ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES. APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT CONTROL (ESC) PLAN SET. ALL THE NOTES ON THE EROSION AND SEDIMENT CONTROL (ESC) STANDARD NOTES: W W P - 2 7 - 4 3 5 3 C 2 5 0 0 1 3 8 2 S-435303 DEVELOPMENT ENGINEERING HBray 12/08/2025 DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR FILEN AM E : SURVEYED: VERTICAL: NAVD 1988 IF NOT ONE INCH ONE INCH AT FULL SCALE HORIZONTAL: NAD 1983/1991 SCALE ACCORDINGLY DATUM Planning/Building/Public Works Dept. CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 4 10 C-4.0 310 320 1+000+00 EXISTING SURFACE EXISTING 8" PVC SEWER MAIN SEWER MAIN PROFILE V: 1"=2' H: 1"=10' 1+80 SCALE IN FEET 0105 10 20 Know what'sbelow. before you dig.Call R NOTE: LEGEND GRAVEL AREA SEE COR STD. PLAN 216.30 FOR DETAILS INLET PROTECTION FOR TESC 6" TEMPORARY ROLLING CURB SEWER MAIN PLAN 2525 RESIDENT SEWER PLAN EXISTING 8" DIAM SEWER MAIN PROPOSED 8" DIAM. PVC SEWER MAIN SEE COR STD. PLAN 214.00 FOR DETAILS SILT FENCE 1 2 SEE WSDOT. SPEC 9-03.12(4) GRAVEL BACKFILL SEE WSDOT. SPEC 9-03.9(3) 95% COMPACTION 6" COMPACTED CSTC ROADWAY TRENCH RESTORATION DETAILS NTS SEE WSDOT. SPEC 9-03.9(3) 95% COMPACTION 1.5' COMPACTED CSBC (UNDER SEPARATE PERMIT) SEEE COR. STD. 406.2 PROPOSED 6" PVC SIDE SEWER MAIN 8" DIAM. PVC, L=115.0', S=0.4% IE=310.62 RIM=319.50 MANHOLE PROPOSED 48" RETORATION LIMIT RETORATION LIMIT RESIDENTS DURING CONSTRUCTION. CONTRACTOR SHALL MAINTAIN ACCESS FOR ALL EXISTING CO REMOVED THE UTILITIES PER RECORD ARE FOR REFERENCE ONLY THE EXISTING IE PRIOR TO CONSTRUCTION CONTRACTOR SHALL FIELD VERIFY CONNECT TO EXISTING 8" SEWER MAIN IE=310.16 RIM=317.52 (N:5374.7190, E: 5385.4971) EXISTING CO. STA.1+115.0 (0') EXISTING PIPE IE PRIOR TO CONSTRUCTION CONTRACTOR SHALL FIELD VERIFY THE SEE COR. STD. 400.1 & 401.1 IE=310.62 RIM=319.50 (N: 5375.0027, E: 5270.4968) PROPOSED 48" MANHOLE STA. 0+00, (0') NOTE 8 ON STD 400.1 2' CONCRETE RING PERW W P - 2 7 - 4 3 5 3 C 2 5 0 0 1 3 8 2 S-435304 MH MH IE=319.0 EXISTING HOUSE SEWER CONNECT WITH EXISTING HOUSE GARAGE FF=317.6 EXISTING HOUSE GARAGE FF=320.9 IE=309.92 RIM=315.69 MANHOLE EXISTING 56" SEE COR.STD. 406.1 IE=315.0 RIM=318.50 CLEAN OUT 6" PVC, L=81.0', S=10.4% IE (W,N,S)=309.92 RIM=315.69 EXISTING 56" MANHOLE 15' PROPOSED 15' EASEMENT RETORATION LIMIT PROPOSED EASEMENT LIMIT FOR TESC 6" TEMPORARY ROLLING CURB LOT LINE PROPOSED SIDE SEWER EXISTING SEWER MAIN EXISTING OVERHEAD POWER LINE EXISTING GAS LINE EXISTING UNDERGROUND POWER LINE EXISTING WATER MAIN 320 3 2 2 324 316 318 1+15 E X IS T IN G H O U S E HEDGE BLOCK WALL CL 0+00 1+00 FF=322.7 FF=320.9 DEVELOPMENT ENGINEERING HBray 12/08/2025 0.5% minimum match slope of existing sewer main. adjust invert as needed to match pipe slope. WASTEWATER UTILITY jstowell 12/09/2025 DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR FILEN AM E : SURVEYED: VERTICAL: NAVD 1988 IF NOT ONE INCH ONE INCH AT FULL SCALE HORIZONTAL: NAD 1983/1991 SCALE ACCORDINGLY DATUM Planning/Building/Public Works Dept. CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS C-5.0 5 9 3/28/2023 TESC DETAIL 2525 RESIDENT SEWER PLAN W W P - 2 7 - 4 3 5 3 C 2 5 0 0 1 3 8 2 S-435305 DEVELOPMENT ENGINEERING HBray 12/08/2025 DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR FILEN AM E : SURVEYED: VERTICAL: NAVD 1988 IF NOT ONE INCH ONE INCH AT FULL SCALE HORIZONTAL: NAD 1983/1991 SCALE ACCORDINGLY DATUM Planning/Building/Public Works Dept. CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS C-6.0 6 10 TESC DETAIL 2525 RESIDENT SEWER PLAN W W P - 2 7 - 4 3 5 3 C 2 5 0 0 1 3 8 2 S-435306 DEVELOPMENT ENGINEERING HBray 12/08/2025 DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR FILEN AM E : SURVEYED: VERTICAL: NAVD 1988 IF NOT ONE INCH ONE INCH AT FULL SCALE HORIZONTAL: NAD 1983/1991 SCALE ACCORDINGLY DATUM Planning/Building/Public Works Dept. CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS SANITARY SEWER NOTES AND SPECIFICATIONS C-7.0 7 10 SEWER MAIN NOTES 2525 RESIDENT SEWER PLAN W W P - 2 7 - 4 3 5 3 C 2 5 0 0 1 3 8 2 S-435307 DEVELOPMENT ENGINEERING HBray 12/08/2025 WASTEWATER UTILITY jstowell 12/09/2025 DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR FILEN AM E : SURVEYED: VERTICAL: NAVD 1988 IF NOT ONE INCH ONE INCH AT FULL SCALE HORIZONTAL: NAD 1983/1991 SCALE ACCORDINGLY DATUM Planning/Building/Public Works Dept. CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS C-8.0 8 10 PR21-000214 B24001658 v1 SEWER MAIN NOTES 2525 RESIDENT SEWER PLAN W W P - 2 7 - 4 3 5 3 C 2 5 0 0 1 3 8 2 S-435308 DEVELOPMENT ENGINEERING HBray 12/08/2025 WASTEWATER UTILITY jstowell 12/09/2025 DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR FILEN AM E : SURVEYED: VERTICAL: NAVD 1988 IF NOT ONE INCH ONE INCH AT FULL SCALE HORIZONTAL: NAD 1983/1991 SCALE ACCORDINGLY DATUM Planning/Building/Public Works Dept. CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS C-9.0 9 10 SEWER DETAILS 2525 RESIDENT SEWER PLAN W W P - 2 7 - 4 3 5 3 C 2 5 0 0 1 3 8 2 S-435309 DEVELOPMENT ENGINEERING HBray 12/08/2025 WASTEWATER UTILITY jstowell 12/09/2025 DATE: FIELDBOOK: DRAWING NO: PAGE: SHEET: OF: SCALE: DESIGNED: DRAWN: CHECKED: APPROVED:NO.REVISION BY DATE APPR FILEN AM E : SURVEYED: VERTICAL: NAVD 1988 IF NOT ONE INCH ONE INCH AT FULL SCALE HORIZONTAL: NAD 1983/1991 SCALE ACCORDINGLY DATUM Planning/Building/Public Works Dept. CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS C-10.0 10 10 TESC DETAIL 2525 RESIDENT SEWER PLAN W W P - 2 7 - 4 3 5 3 C 2 5 0 0 1 3 8 2 S-435310 DEVELOPMENT ENGINEERING HBray 12/08/2025 WASTEWATER UTILITY jstowell 12/09/2025