HomeMy WebLinkAboutD_Admin_Falcon_Falcon_Ridge_Special_Fence_Permit_180619.pdfDEPARTMENTOFCOMMUNITYANDECONOMICDEVELOPMENTPLANNINGDIVISIONADMINISTRATIVESPECIALFENCEPERMITDATE:PROJECTNUMBER:PROJECTNAME:PROJECTMANAGER:OWNER:June19,2018LUA18-000390FalconRidgeLiftStationSpecialFenceAngeleaWeihs,AssoicatePlannerMichaelBenoit,CityofRenton-Sewer1055SGradyWayRenton,WA98057PROJECTLOCATION:PARCELNUMBER:PROJECTDESCRIPTION&ANALYSIS:2123059003TheRentonWastewaterUtilityisproposingthereplacementoftheFalconRidgeLiftStationlocatedonTractB(247520TR-B)ofFalconRidge(AKACedarRidge)Development.ThenewreplacementliftstationwillbelocatedonabuttinglandcurrentlyownedbytheCityParksDepartment,eastoftheexistingliftstation(parcel2123059003).Aspartofthenewstationconstruction,RentonWastewaterUtilityisrequestingapprovalofaSpecialFencePermitfortheproposedinstallationofa6-foottall,blackvinylcoated,chainlinkfencelocatedwithinthefrontyardsetback,alongtheprivatestreetfrontage(SeeExhibit1).Thenewstationwillbebuiltonundeveloped,woodedCityparkspropertyattheendofaprivateroad(SE8thP1).Theproposednewliftstationwouldhavenopublicstreetfrontageandwouldaccessfromtheprivatestreet.Thefront(westerly)sideolthefencewillbealongthewestpropertyline.Thispropertylineisattheendofandperpendiculartotheprivateroadway.Therearenosidewalksinthevicinityandcitystaffdoesnotanticipateanyimpacttovehicularorpedestriantraffic.ThegoalofthEapplicantistoutilizeaslittleoftheparkpropertyaspossibleandtoleave/restorethesurroundingareaitsnaturalwoodedform.Theapplicantproposesadark-coatedchainlinkinorderto:increasesecurityofthefacilitybymakingthesitemorevisiblefromthestreet;andallowthefencetoblendintothewoodedbackground.Theapplicantstatesthattheproposedfencewouldnobeoutofplaceforthesurroundingarea.TheexistingstationhasachainlinkfencethatwillberemovedandtheadjacentpropertytothesouthwestisanRVstorageareabelongingtothehomeownersassociationthatisenclosedbyachainlinkfence.Pagelof2ofedlttoEast of SE 8th Pl and SE 8th DrDocuSign Envelope ID: 0BF93A18-6A60-4B72-B0FC-CF0D158C7244
CityofRentonDepartmentofCommunity&EconomicDevelopmentAdministrativeSpecialFencePermitFalconRidgeLiftStationSpecialFenceLUA18-000390FENCELOCATION:ElCleatVisionAreaF:FrontYardERearYardi:iRearYardAlongaStreetLISideYardESideYardAlongaStreetFENCEDESIGN:IncreasedSetbacksfromSidewalksModulationofFencenOrnamentalMaterialsorConstructionElPermanentLandscapingEQualityFenceMaterialsESimilartoDesign&MaterialofSurroundingFenceEVALUATIONCRITERIA:ImprovesPrivacy:AchievedLimitsBlankwallsAlongWalkway:AchievedInScalewithNeighborhood:AchievedDoesNotCreateaTrafficHazard:AchievedAestheticallyPleasing:AchievedDECISION:ApprovedSIGNATURE&DATEOFDECISION:JenniferHenning,PlanningDirectorDateADVISORYNOTE:TheapplicantshouldcontacttheUtilityNotificationCenter,bydialing800-424-5555,todeterminethelocationofundergroundutilities(telephone,streetlights,cable,electric),whichmaybelocatedbehindthesidewalk.Appealsofpermitissuancemustbefiledinwritingonorbefore5:00p.m.onJuly03,2018,togetherwiththerequiredfeewith:HearingExaminer,CityofRenton,1055SouthGradyWay,Renton,WA98057.AppealstotheExamineraregovernedbyRMC4-8-110andmoreinformationregardingtheappealprocessmaybeobtainedfromtheRentonCityClerk’sOffice,425-430-6510.Reconsideration:Within14daysofthedecisiondate,anypartymayrequestthatthedecisionbereopenedbytheapprovalbody.TheapprovalbodymaymodifyhisdecisionifmaterialevidencenotreadilydiscoverablepriortothEoriginaldecisionisfoundorifhefindstherewasmisrepresentationoffact.Afterreviewofthereconsiderationrequest,iftheapprovalbodyfindssufficientevidencetoamendtheoriginaldecision,therewillbenofurtherextensionoftheappealperiod.Anypersonwishingtotakefurtheractionmustfileaformalappealwithinthe14-dayappealtimeframe.Page2of2eDocuSign Envelope ID: 0BF93A18-6A60-4B72-B0FC-CF0D158C72446/19/2018 | 2:08 PM PDT
EXHIBIT 1DocuSign Envelope ID: 0BF93A18-6A60-4B72-B0FC-CF0D158C7244
AHFEHApr 9, 2018Apr 9, 2018REN117-038FCLS-D-CIV05.DWGSHOWN
C06 7 32
DWG NO.:DATEDESCRIPTIONREVISIONSBYREVIEWENGINEER:SAVE DATE:REVIEWED:PLOT DATE:CLIENT:FILENAME:SHEET NO.:JOB NO.:NO.0"1"2"
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
SCALE:PRELIMINARYwww.rh2.comRH2 ENGINEERING, INC.Bothell, Wa22722 29th Drive SE, Suite 2101.800.720.8052CIVIL DETAILS IICITY OF RENTONFALCON RIDGE LIFT STATIONCITY OF RENTONFALCON RIDGE LIFT STATIONTEMPORARY CHAIN-LINK FENCE
208
GROUND SURFACE
STABILIZER BRACKET, TYP.
6' TALL TEMPORARY
CHAIN-LINK FENCE PANEL, TYP.
CHAIN-LINK FENCE
LINE POST HOLE CONCRETE:
MIN. DEPTH = 48"
MIN. DIAMETER = 18"
MIN. POST EMBEDMENT = 24"
10' MAX.10' MAX.
6'-0"
CHAIN-LINK DOUBLE SWING GATE DETAIL
MAN ACCESS GATE DETAIL
12"
20'-0"
ALL CHAIN LINK FENCE
SHALL BE BLACK VINYL
COATED MIN. 3 MILS DFT.
6'-0"
GATE POST HOLE CONCRETE:
MIN. DEPTH = 54"
MIN. DIAMETER = 24"
MIN. POST EMBEDMENT = 24"
1-2/3" O.D. INTERMEDIATE
BRACE RAIL
6 GAGE BANDS, @ 14"
2 3/8" O.D. LINE POST
MAX. @ 10' O.C.
1 5/8" O.D. TOP AND
BOTTOM RAIL
3/8" TIE ROD
2-7/8" O.D. END POST
9 GAGE WIRE
CLIPS, @ 24"
3/8" TIE ROD, TYP.
CMU BUILDING
4" O.D. GATE POST
BOTTOM HINGE
180° SWING
ROD MUST SIT
4"-6" IN CONCRETE
TOP HINGE
180° SWING
4" O.D. GATE POST
210
209
WALL-MOUNT (FLAT BACK)
GATE LATCH WITH PADLOCK
3'-0"
211
DocuSign Envelope ID: 0BF93A18-6A60-4B72-B0FC-CF0D158C7244
April 24, 2018
City of Renton
Community Economic Development
1055 S Grady Way
Renton, WA 98057
RE: Proposed Fence Falcon Ridge Lift Station
The Renton Wastewater Utility is proposing the replacement of the Falcon Ridge Lift Station. As part of
the new station construction, we are proposing the installation of a 6-foot tall chain link fence. The
fence will be black vinyl coated.
The station is being built on undeveloped (wooded) City parks property at the end of a private road.
(There is not public right-of-way in the vicinity.) It is the goal of the project to utilize as little of the park
property as possible and to leave / restore the surrounding area in its natural wooded form.
We are proposing the dark coated chain link for two reasons. On e is to allow open view onto the sight
while providing security. The second is that the open mesh will allow the fence to blend into the
wooded background.
The fence would not be out of place for the surrounding area. The existing station has a chain li nk
fence that will be removed. The adjacent property to the south and west is an RV storage area
belonging to the homeowners association that is enclosed by a chain link fence.
The front (westerly) side of the fence will be along the property line. This property line is at the end of
and perpendicular to the private roadway. There are not any sidewalks in the vicinity. There is not any
impact to vehicular or pedestrian traffic.
Please contact me at 425-430-7206 or mbenoit@rentonwa.gov if you have any questions.
Sincerely,
Michael A. Benoit
Michael A. Benoit
Project Manager
Wastewater Utility
EXHIBIT 2
DocuSign Envelope ID: 0BF93A18-6A60-4B72-B0FC-CF0D158C7244