Loading...
HomeMy WebLinkAboutAPPROVED_SRTC IFB Design Drawings Book 2 of 3C ENTRAL PUGET SOUND REGIONAL TRANSIT AUTHORITY DRAWING No.: SHEET No.:REV: LOCATION ID: THE PREPARATION OF THIS DOCUMENT HAS BEEN FINANCED IN PART THROUGH A GRANT FROM THE U.S. DEPARTMENT OF TRANSPORTATION FEDERAL TRANSIT ADMINISTRATION UNDER THE URBAN MASS TRANSPORTATION ACT OF 1964, AS AMENDED, AND IN PART BY THE CENTRAL PUGET SOUND REGIONAL TRANSIT AUTHORITY DISTRICT OF WASHINGTON, AND THE STATE OF WASHINGTON REVIEWED BY: NAME: TITLE: DATE: 06 / 1 2 / 2 5 | 1 : 2 3 P M | Y S H E N C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S H E N Y \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z T 0 0 1 . D W G PREPARED BY: SUBMITTED BY: NAME: TITLE: DATE: STRIDE BUS RAPID TRANSIT RTA/CN 0205-24SOUTH RENTON TRANSIT CENTER ISSUED FOR BIDMAY 2025 RICARDO PARGAS PROJECT MANAGER JOEY ALTCHECH PROJECT MANAGER BT120-GZT001 BT120 S1-BT105 VOLUME 1 AND ROADWAY IMPROVEMENTS GENERAL ENGINEERING CONSULTANT SERVICES CONTRACT LOCATION MAP PROJECT LOCATION N 1 1 1 06/12/2025 06/12/2025 BOOK 1 OF 3 1 BT120-GZT001 0 GENERAL COVER SHEET 2 BT120-GZI001 0 GENERAL INDEX OF DRAWINGS 3 BT120-GZI002 0 GENERAL INDEX OF DRAWINGS 4 BT120-GZI003 0 GENERAL INDEX OF DRAWINGS 5 BT120-GZI004 0 GENERAL INDEX OF DRAWINGS 6 BT120-GZI005 0 GENERAL INDEX OF DRAWINGS 7 BT120-GZI006 0 GENERAL INDEX OF DRAWINGS 8 BT120-GZI701 0 GENERAL INDEX OF DRAWINGS SR 167 9 BT120-GZK000 0 GENERAL PROJECT LOCATION ID PLAN 10 BT120-GZK001 0 GENERAL KEY PLAN 11 BT120-GZN001 0 GENERAL ABBREVIATIONS 12 BT120-GZN002 0 GENERAL ABBREVIATIONS 13 BT120-GZN003 0 GENERAL ABBREVIATIONS 14 BT120-GZN004 0 GENERAL ABBREVIATIONS 15 BT120-GZN005 0 GENERAL ABBREVIATIONS 16 BT120-GZN006 0 GENERAL SYMBOLS AND LEGEND 17 BT120-GZN007 0 GENERAL SYMBOLS AND LEGEND 18 BT120-RMP501 0 RIGHT OF WAY MONUMENT PLAN 19 BT120-RPP101 0 RIGHT OF WAY PROPOSED PLAN RAINIER STA 200+00 TO RAINIER STA 204+00 20 BT120-RPP102 0 RIGHT OF WAY PROPOSED PLAN RAINIER STA 204+00 TO RAINIER STA 208+50 21 BT120-RPP103 0 RIGHT OF WAY PROPOSED PLAN RAINIER STA 208+50 TO RAINIER STA 214+00 22 BT120-RPP104 0 RIGHT OF WAY PROPOSED PLAN GRADY STA 151+00 TO GRADY STA 156+50 23 BT120-RPP105 0 RIGHT OF WAY PROPOSED PLAN GRADY STA 156+50 TO GRADY STA 160+46 24 BT120-RPP106 0 RIGHT OF WAY PROPOSED PLAN LAKE STA 401+50 TO LAKE STA 405+55 25 BT120-RPP201 0 RIGHT OF WAY PROPOSED PLAN 26 BT120-RPP202 0 RIGHT OF WAY PROPOSED PLAN 27 BT120-RPP203 0 RIGHT OF WAY PROPOSED PLAN 28 BT120-RPP204 0 RIGHT OF WAY PROPOSED PLAN 29 BT120-RPP205 0 RIGHT OF WAY PROPOSED PLAN 30 BT120-CAP100 0 CIVIL ALIGNMENT PLAN AREA PLAN 31 BT120-CAP101 0 CIVIL ALIGNMENT PLAN RAINIER STA 200+00 TO RAINIER STA 204+00 32 BT120-CAP102 0 CIVIL ALIGNMENT PLAN RAINIER STA 204+00 TO RAINIER STA 208+50 33 BT120-CAP103 0 CIVIL ALIGNMENT PLAN RAINIER STA 208+50 TO RAINIER STA 212+42.13 34 BT120-CAP104 0 CIVIL ALIGNMENT PLAN GRADY STA 151+00 TO GRADY STA 156+50 35 BT120-CAP105 0 CIVIL ALIGNMENT PLAN GRADY STA 156+50 TO GRADY STA 160+46.15 36 BT120-CAP106 0 CIVIL ALIGNMENT PLAN LAKE STA 401+50 TO LAKE STA 405+50 37 BT120-CAP107 0 CIVIL ALIGNMENT PLAN LAKE STA 405+50 TO LAKE STA 408+28.91 38 BT120-CAP201 0 CIVIL ALIGNMENT PLAN S RENTON TRANSIT CENTER 39 BT120-CAP202 0 CIVIL ALIGNMENT PLAN S RENTON TRANSIT CENTER 40 BT120-CAP203 0 CIVIL ALIGNMENT PLAN S RENTON TRANSIT CENTER 41 BT120-CAP204 0 CIVIL ALIGNMENT PLAN S RENTON TRANSIT CENTER 43 BT120-CRY101 0 CIVIL TYPICAL SECTIONS RAINIER AVE S 44 BT120-CRY102 0 CIVIL TYPICAL SECTIONS RAINIER AVE S AND HARDIE AVE SW 45 BT120-CRY103 0 CIVIL TYPICAL SECTIONS S RENTON TRANSIT CENTER 46 BT120-CRY104 0 CIVIL TYPICAL SECTIONS GRADY WAY 47 BT120-CRY105 0 CIVIL TYPICAL SECTIONS GRADY WAY AND PARKING LOTS 48 BT120-CRY106 0 CIVIL TYPICAL SECTIONS LAKE AVE S AND RAINIER AND LAKE DRIVEWAY 66 BT120-CSP100 0 CIVIL SITE PREPARATION PLAN AREA PLAN AND GENERAL NOTES 67 BT120-CSP101 0 CIVIL SITE PREPARATION PLAN RAINIER STA 200+00 TO RAINIER STA 204+00 68 BT120-CSP102 0 CIVIL SITE PREPARATION PLAN RAINIER STA 204+00 TO RAINIER STA 208+50 69 BT120-CSP103 0 CIVIL SITE PREPARATION PLAN RAINIER STA 208+50 TO RAINIER STA 212+42.13 70 BT120-CSP104 0 CIVIL SITE PREPARATION PLAN GRADY STA 151+00 TO GRADY STA 156+50 71 BT120-CSP105 0 CIVIL SITE PREPARATION PLAN GRADY STA 156+50 TO GRADY STA 160+46.15 72 BT120-CSP106 0 CIVIL SITE PREPARATION PLAN LAKE STA 401+50 TO LAKE STA 405+55.16 73 BT120-CSP107 0 CIVIL SITE PREPARATION PLAN LAKE STA 405+50 TO LAKE STA 408+28.91 74 BT120-CSP201 0 CIVIL SITE PREPARATION PLAN S RENTON TRANSIT CENTER 75 BT120-CSP202 0 CIVIL SITE PREPARATION PLAN S RENTON TRANSIT CENTER 76 BT120-CSP203 0 CIVIL SITE PREPARATION PLAN S RENTON TRANSIT CENTER 77 BT120-CSP204 0 CIVIL SITE PREPARATION PLAN S RENTON TRANSIT CENTER 78 BT120-CSP205 0 CIVIL SITE PREPARATION PLAN S RENTON TRANSIT CENTER 79 BT120-CSS101 0 CIVIL SITE PREP POINT TABLE 80 BT120-CSS102 0 CIVIL SITE PREP POINT TABLE 42 BT120-CHP101 0 CIVIL TRAFFIC HAUL PLAN SOUTH RENTON TRANSIT CENTTER 49 BT120-CTP100 0 CIVIL TESC PLAN AREA PLAN AND GENERAL NOTES 50 BT120-CTP101 0 CIVIL TESC PLAN RAINIER STA 200+00 TO RAINER STA 204+00 51 BT120-CTP102 0 CIVIL TESC PLAN RAINER STA 204+00 TO RAINIER STA 208+50 52 BT120-CTP103 0 CIVIL TESC PLAN RAINIER STA 208+50 TO RAINIER STA 212+42.13 53 BT120-CTP104 0 CIVIL TESC PLAN GRADY STA 151+00 TO GRADY STA 156+50 54 BT120-CTP105 0 CIVIL TESC PLAN GRADY STA 156+50 TO GRADY STA 160+46.15 55 BT120-CTP106 0 CIVIL TESC PLAN LAKE STA 401+50 TO LAKE STA 405+50 56 BT120-CTP201 0 CIVIL TESC PLAN S RENTON TRANSIT CENTER 57 BT120-CTP202 0 CIVIL TESC PLAN S RENTON TRANSIT CENTER 58 BT120-CTP203 0 CIVIL TESC PLAN S RENTON TRANSIT CENTER 59 BT120-CTP204 0 CIVIL TESC PLAN S RENTON TRANSIT CENTER 60 BT120-CTP205 0 CIVIL TESC PLAN S RENTON TRANSIT CENTER 61 BT120-CTN101 0 CIVIL STANDARD TESC NOTES 62 BT120-CTD101 0 CIVIL STANDARD TESC DETAILS 63 BT120-CTD102 0 CIVIL STANDARD TESC DETAILS 81 BT120-CPP100 0 CIVIL PAVING PLAN AREA PLAN AND GENERAL NOTES 82 BT120-CPP101 0 CIVIL PAVING PLAN RAINIER STA 200+00 TO RAINIER STA 204+00 83 BT120-CPP102 0 CIVIL PAVING PLAN RAINIER STA 504+00 TO RAINIER STA 208+50 84 BT120-CPP103 0 CIVIL PAVING PLAN RAINIER STA 208+50 TO RAINIER STA 212+42.13 85 BT120-CPP104 0 CIVIL PAVING PLAN GRADY STA 151+00 TO GRADY STA 156+50 86 BT120-CPP105 0 CIVIL PAVING PLAN GRADY STA 156+50 TO GRADY STA 160+46.15 87 BT120-CPP106 0 CIVIL PAVING PLAN LAKE STA 401+50 TO LAKE STA 405+55.16 88 BT120-CPP201 0 CIVIL PAVING PLAN S RENTON TRANSIT CENTER 89 BT120-CPP202 0 CIVIL PAVING PLAN S RENTON TRANSIT CENTER 90 BT120-CPP203 0 CIVIL PAVING PLAN S RENTON TRANSIT CENTER 91 BT120-CPP204 0 CIVIL PAVING PLAN S RENTON TRANSIT CENTER 92 BT120-CPP205 0 CIVIL PAVING PLAN S RENTON TRANSIT CENTER 93 BT120-CPS101 0 CIVIL PAVING PLAN POINT TABLES 94 BT120-CPS102 0 CIVIL PAVING PLAN POINT TABLES 95 BT120-CPS103 0 CIVIL PAVING PLAN POINT TABLES 96 BT120-CPS104 0 CIVIL PAVING PLAN POINT TABLES 97 BT120-CPS105 0 CIVIL PAVING PLAN POINT TABLES 98 BT120-CPS106 0 CIVIL PAVING PLAN POINT TABLES 99 BT120-CPS107 0 CIVIL PAVING PLAN POINT TABLES 100 BT120-CPS108 0 CIVIL PAVING PLANS POINT TABLES 101 BT120-CAV101 0 CIVIL VERTICAL ALIGNMENT N TRANSIT CENTER 102 BT120-CAV102 0 CIVIL VERTICAL ALIGNMENT S TRANSIT CENTER 103 BT120-CAV103 0 CIVIL VERTICAL ALIGNMENT RAINIER AND LAKE DRIVEWAY 104 BT120-CAV104 0 CIVIL VERTICAL ALIGNMENT LAKE AVE S 105 BT120-CRD101 0 CIVIL CURB RAMP PLAN AND DETAILS 106 BT120-CRD102 0 CIVIL CURB RAMP PLAN AND DETAILS 107 BT120-CRD103 0 CIVIL CURB RAMP PLAN AND DETAILS 108 BT120-CRD104 0 CIVIL CURB RAMP PLAN AND DETAILS 109 BT120-CRD105 0 CIVIL CURB RAMP PLAN AND DETAILS 110 BT120-CRD106 0 CIVIL CURB RAMP PLAN AND DETAILS 111 BT120-CRD107 0 CIVIL CURB RAMP PLAN AND DETAILS 112 BT120-CRD108 0 CIVIL CURB RAMP PLAN AND DETAILS 113 BT120-CRD109 0 CIVIL CURB RAMP PLAN AND DETAILS 114 BT120-CRD110 0 CIVIL CURB RAMP PLAN AND DETAILS 115 BT120-CRD111 0 CIVIL CURB RAMP PLAN AND DETAILS 116 BT120-CRD112 0 CIVIL CURB RAMP PLAN AND DETAILS 117 BT120-CRD113 0 CIVIL CURB RAMP PLAN AND DETAILS 118 BT120-CRD114 0 CIVIL CURB RAMP PLAN AND DETAILS 119 BT120-CRD115 0 CIVIL CURB RAMP PLAN AND DETAILS 120 BT120-CRD116 0 CIVIL CURB RAMP PLAN AND DETAILS 121 BT120-CRD117 0 CIVIL CURB RAMP PLAN AND DETAILS 122 BT120-CRD118 0 CIVIL CURB RAMP PLAN AND DETAILS 123 BT120-CRD119 0 CIVIL CURB RAMP PLAN AND DETAILS 124 BT120-CRD120 0 CIVIL PAVING DETAILS 125 BT120-CRD121 0 CIVIL PAVING DETAILS 126 BT120-CRD122 0 CIVIL PAVING DETAILS 127 BT120-CRD123 0 CIVIL PAVING DETAILS 128 BT120-CRD124 0 CIVIL PAVING DETAILS 64 BT120-CTD103 0 CIVIL STANDARD TESC DETAILS 65 BT120-CTD104 0 CIVIL STANDARD TESC DETAILS GENERAL RIGHT-OF-WAY SHT. No. DWG. No.TITLEREV SHT. No. DWG. No.TITLEREV CIVIL (CONT'D) CIVIL ALIGNMENT SOUTH RENTON TRANSIT CENTER - BOOK 1 OF 3 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL INDEX OF DRAWINGS BT120-GZI001 BT120 E. GOLLER E. GOLLER L. GILBERT J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS CONSTRUCTION STAGING ROADWAY No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 12 / 0 4 / 2 4 | 8 : 2 6 A M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z I 0 0 1 - 0 0 6 . D W G S1-BT120-GZI001-006 FACILITY ID: Xrefs: xBRT-CUD05-TB22x34 xS1-BT120-GZI001 GB-SEAL-JKH53550 TYPICAL SECTIONS EROISION AND SEDIMENT CONTROL SITE EROISION AND SEDIMENT CONTROL (CONT'D) 12/06/2024 0002 RTA/CN 0205-24 134 BT120-CMP100 0 CIVIL CHANNELIZATION AND SIGNING PLAN AREA PLAN AND GENERAL NOTES 135 BT120-CMP101 0 CIVIL CHANNELIZATION AND SIGNING PLAN RAINIER STA 200+00 TO RAINIER STA 204+00 136 BT120-CMP102 0 CIVIL CHANNELIZATION AND SIGNING PLAN RAINIER STA 204+00 TO RAINIER STA 208+50 137 BT120-CMP103 0 CIVIL CHANNELIZATION AND SIGNING PLAN RAINIER STA 208+50 TO RAINIER STA 212+42.13 138 BT120-CMP104 0 CIVIL CHANNELIZATION AND SIGNING PLAN GRADY STA 151+00 TO GRADY STA 156+50 139 BT120-CMP105 0 CIVIL CHANNELIZATION AND SIGNING PLAN GRADY STA 156+50 TO GRADY STA 160+46.15 140 BT120-CMP106 0 CIVIL CHANNELIZATION AND SIGNING PLAN LAKE STA 401+50 TO LAKE STA 405+50 141 BT120-CMP107 0 CIVIL CHANNELIZATION AND SIGNING PLAN LAKE STA 405+50 TO LAKE STA 408+28.91 142 BT120-CMP201 0 CIVIL CHANNELIZATION AND SIGNING PLAN S RENTON TRANSIT CENTER 143 BT120-CMP202 0 CIVIL CHANNELIZATION AND SIGNING PLAN S RENTON TRANSIT CENTER 144 BT120-CMP203 0 CIVIL CHANNELIZATION AND SIGNING PLAN S RENTON TRANSIT CENTER 145 BT120-CMP204 0 CIVIL CHANNELIZATION AND SIGNING PLAN S RENTON TRANSIT CENTER 146 BT120-CMP205 0 CIVIL CHANNELIZATION AND SIGNING PLAN S RENTON TRANSIT CENTER 147 BT120-CMS101 0 CIVIL SIGN SCHEDULE PROPOSED 148 BT120-CMS102 0 CIVIL SIGN SCHEDULE PROPOSED 149 BT120-CMS103 0 CIVIL SIGN SCHEDULE PROPOSED 150 BT120-CMS104 0 CIVIL CHANNELIZATION DETAILS 151 BT120-CMD101 0 CIVIL SIGN DETAILS 152 BT120-CMD102 0 CIVIL SIGN DETAILS 153 BT120-CMD103 0 CIVIL SIGN DETAILS 154 BT120-CMD104 0 CIVIL CHANNELIZATION DETAILS 155 BT120-CMD105 0 CIVIL CHANNELIZATION DETAILS 156 BT120-CMD106 0 CIVIL CHANNELIZATION DETAILS 157 BT120-CMD107 0 CIVIL CHANNELIZATION DETAILS 158 BT120-CGP101 0 CIVIL GRADING PLAN RAINIER/HARDIE INTERSECTION 159 BT120-CGP102 0 CIVIL GRADING PLAN BEB CHARGING, GENERATOR & DUMPSTER LOCATIONS 160 BT120-CGP103 0 CIVIL GRADING PLAN TRANSIT CENTER 161 BT120-CGS101 0 CIVIL GRADING PLAN POINT TABLES 162 BT120-CGS102 0 CIVIL GRADING PLAN POINT TABLES 163 BT120-CDP100 0 CIVIL DRAINAGE PLAN AREA PLAN AND GENERAL NOTES 164 BT120-CDP102 0 CIVIL DRAINAGE PLAN RAINIER STA 204+00 TO RAINIER STA 208+50 165 BT120-CDP104 0 CIVIL DRAINAGE PLAN GRADY STA 151+00 TO GRADY STA 156+50 166 BT120-CDP105 0 CIVIL DRAINAGE PLAN GRADY STA 156+50 TO GRADY STA 160+46.15 167 BT120-CDP106 0 CIVIL DRAINAGE PLAN LAKE STA 401+50 TO LAKE STA 405+50 168 BT120-CDP201 0 CIVIL DRAINAGE PLAN S RENTON TRANSIT CENTER 169 BT120-CDP202 0 CIVIL DRAINAGE PLAN S RENTON TRANSIT CENTER 170 BT120-CDP203 0 CIVIL DRAINAGE PLAN S RENTON TRANSIT CENTER 171 BT120-CDP204 0 CIVIL DRAINAGE PLAN S RENTON TRANSIT CENTER 172 BT120-CDP205 0 CIVIL DRAINAGE PLAN S RENTON TRANSIT CENTER 173 BT120-CDV201 0 CIVIL DRAINAGE PROFILE S RENTON TRANSIT CENTER 174 BT120-CDV202 0 CIVIL DRAINAGE PROFILE S RENTON TRANSIT CENTER 175 BT120-CDV203 0 CIVIL DRAINAGE PROFILE S RENTON TRANSIT CENTER 176 BT120-CDV204 0 CIVIL DRAINAGE PROFILE S RENTON TRANSIT CENTER 177 BT120-CDV205 0 CIVIL DRAINAGE PROFILE S RENTON TRANSIT CENTER 178 BT120-CDV206 0 CIVIL DRAINAGE PROFILE S RENTON TRANSIT CENTER 179 BT120-CDV207 0 CIVIL DRAINAGE PROFILE 180 BT120-CDD501 0 CIVIL DRAINAGE DETAILS 181 BT120-CDD502 0 CIVIL DRAINAGE DETAILS 182 BT120-CDD503 0 CIVIL DRAINAGE DETAILS 183 BT120-CDD504 0 CIVIL DRAINAGE DETAILS 184 BT120-CDD505 0 CIVIL DRAINAGE DETAILS 185 BT120-CDD506 0 CIVIL DRAINAGE DETAILS 186 BT120-CLN101 0 CIVIL ILLUMINATION PLAN LEGEND 187 BT120-CLP100 0 CIVIL ILLUMINATION PLAN AREA PLAN AND GENERAL NOTES 188 BT120-CLP102 0 CIVIL ILLUMINATION PLAN RAINIER STA 204+00 TO RAINIER STA 208+50 189 BT120-CLP104 0 CIVIL ILLUMINATION PLAN GRADY STA 151+00 TO GRADY STA 156+50 190 BT120-CLP105 0 CIVIL ILLUMINATION PLAN GRADY STA 156+50 TO GRADY STA 160+46.15 191 BT120-CLP106 0 CIVIL ILLUMINATION PLAN LAKE STA 401+50 TO LAKE STA 405+50 192 BT120-CLP201 0 CIVIL ILLUMINATION PLAN S RENTON TRANSIT CENTER 193 BT120-CLP202 0 CIVIL ILLUMINATION PLAN S RENTON TRANSIT CENTER 194 BT120-CLP203 0 CIVIL ILLUMINATION PLAN S RENTON TRANSIT CENTER 195 BT120-CLP204 0 CIVIL ILLUMINATION PLAN S RENTON TRANSIT CENTER 196 BT120-CLP205 0 CIVIL ILLUMINATION PLAN S RENTON TRANSIT CENTER 197 BT120-CLS101 0 CIVIL ILLUMINATION SCHEDULES 198 BT120-CLS102 0 CIVIL ILLUMINATION SCHEDULES 199 BT120-CLS103 0 CIVIL ILLUMINATION SCHEDULES 200 BT120-UCP100 0 UTILITIES DEMO PLAN AREA PLAN AND GENERAL NOTES 201 BT120-UCP102 0 UTILITIES DEMO PLAN RAINIER STA 204+00 TO RAINIER STA 208+50 202 BT120-UCP104 0 UTILITIES DEMO PLAN GRADY STA 151+00 TO GRADY STA 156+50 203 BT120-UCP105 0 UTILITIES DEMO PLAN GRADY STA 156+50 TO GRADY STA 160+46.15 204 BT120-UCP106 0 UTILITIES DEMO PLAN LAKE STA 401+50 TO LAKE STA 405+50 205 BT120-UCP201 0 UTILITIES DEMO PLAN S RENTON TRANSIT CENTER 206 BT120-UCP202 0 UTILITIES DEMO PLAN S RENTON TRANSIT CENTER 207 BT120-UCP203 0 UTILITIES DEMO PLAN S RENTON TRANSIT CENTER 208 BT120-UCP204 0 UTILITIES DEMO PLAN S RENTON TRANSIT CENTER 209 BT120-UCP205 0 UTILITIES DEMO PLAN S RENTON TRANSIT CENTER 210 BT120-UWP100 0 UTILITIES WATER PLANS AREA PLAN AND GENERAL NOTES 211 BT120-UWP101 0 UTILITIES WATER PLANS RAINIER STA 200+00 TO RAINIER STA 204+00 212 BT120-UWP102 0 UTILITIES WATER PLANS RAINIER STA 204+00 TO RAINIER STA 208+50 213 BT120-UWP104 0 UTILITIES WATER PLANS GRADY STA 151+00 TO GRADY STA 156+50 214 BT120-UWP105 0 UTILITIES WATER PLANS GRADY STA 156+50 TO GRADY STA 160+46.15 215 BT120-UWP106 0 UTILITIES WATER PLAN LAKE STA 401+50 TO LAKE STA 405+50 216 BT120-UWP201 0 UTILITIES WATER PLANS S RENTON TRANSIT CENTER 217 BT120-UWP202 0 UTILITIES WATER PLANS S RENTON TRANSIT CENTER 218 BT120-UWP203 0 UTILITIES WATER PLAN S RENTON TRANSIT CENTER 219 BT120-UWP204 0 UTILITIES WATER PLAN S RENTON TRANSIT CENTER 220 BT120-UWP205 0 UTILITIES WATER PLAN S RENTON TRANSIT CENTER 221 BT120-UWV101 0 UTILITIES WATER PROFILE S RENTON TRANSIT CENTER 222 BT120-UWV102 0 UTILITIES WATER PROFILE S RENTON TRANSIT CENTER 223 BT120-UWV103 0 UTILITIES WATER PROFILE S RENTON TRANSIT CENTER 224 BT120-UWV104 0 UTILITIES WATER PROFILE S RENTON TRANSIT CENTER 225 BT120-UWV105 0 UTILITIES WATER PROFILE S RENTON TRANSIT CENTER 226 BT120-UWD101 0 UTILITIES WATER DETAILS S RENTON TRANSIT CENTER 227 BT120-USP100 0 UTILITIES SEWER PLAN AREA PLAN AND GENERAL NOTES 228 BT120-USP102 0 UTILITIES SEWER PLAN RAINIER STA 204+00 TO RAINIER STA 208+50 229 BT120-USP104 0 UTILITIES SEWER PLAN GRADY STA 151+00 TO GRADY STA 156+50 230 BT120-USP105 0 UTILITIES SEWER PLAN GRADY STA 156+50 TO GRADY STA 160+46.15 231 BT120-USP201 0 UTILITIES SEWER PLAN S RENTON TRANSIT CENTER 232 BT120-USP202 0 UTILITIES SEWER PLAN S RENTON TRANSIT CENTER 233 BT120-USP203 0 UTILITIES SEWER PLAN S RENTON TRANSIT CENTER 234 BT120-USP204 0 UTILITIES SEWER PLAN S RENTON TRANSIT CENTER 235 BT120-USP205 0 UTILITIES SEWER PLAN S RENTON TRANSIT CENTER 236 BT120-USV101 0 UTILITIES SEWER PROFILE S RENTON TRANSIT CENTER 237 BT120-USV102 0 UTILITIES SEWER PROFILE S RENTON TRANSIT CENTER 129 BT120-CRD125 0 CIVIL FENCE DETAILS 130 BT120-CRD126 0 CIVIL FENCE GATE DETAIL 131 BT120-CRD127 0 CIVIL STEEL PICKET VEHICLE GATE DETAIL 132 BT120-CRD128 0 CIVIL WHEEL STOP DETAIL 133 BT120-CRD129 0 CIVIL ROADWAY BOLLARD TYPE 1 DETAIL SHT. No. DWG. No.TITLEREV SHT. No. DWG. No.TITLEREV CIVIL (CONT'D) STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL INDEX OF DRAWINGS BT120-GZI002 BT120 E. GOLLER E. GOLLER L. GILBERT J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS ILLUMINATION No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 12 / 0 4 / 2 4 | 8 : 2 6 A M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z I 0 0 1 - 0 0 6 . D W G S1-BT120-GZI001-006 FACILITY ID: Xrefs: xBRT-CUD05-TB22x34 xS1-BT120-GZI001 GB-SEAL-JKH53550 SOUTH RENTON TRANSIT CENTER - BOOK 1 OF 3 PAVEMENT MARKING GRADING DRAINAGE UTILITIES ROADWAY (CONT'D) CIVIL (CONT'D) 12/06/2024 0003 RTA/CN 0205-24 271 BT120-LHP100 0 LANDSCAPE HARDSCAPE PLAN AREA PLAN AND GENERAL NOTES 272 BT120-LHP102 0 LANDSCAPE HARDSCAPE PLAN BURIEN TC 273 BT120-LHP104 0 LANDSCAPE HARDSCAPE PLAN GRADY STA 151+00 TO GRADY STA 156+50 274 BT120-LHP105 0 LANDSCAPE HARDSCAPE PLAN GRADY STA 156+50 TO GRADY STA 160+46.15 275 BT120-LHP106 0 LANDSCAPE HARDSCAPE PLAN BURIEN TRANSIT CENTER 276 BT120-LHP201 0 LANDSCAPE HARDSCAPE PLAN S RENTON TRANSIT CENTER 277 BT120-LHP202 0 LANDSCAPE HARDSCAPE PLAN S RENTON TRANSIT CENTER 278 BT120-LHP203 0 LANDSCAPE HARDSCAPE PLAN S RENTON TRANSIT CENTER 279 BT120-LHP204 0 LANDSCAPE HARDSCAPE PLAN S RENTON TRANSIT CENTER 280 BT120-LHP205 0 LANDSCAPE HARDSCAPE PLAN S RENTON TRANSIT CENTER 281 BT120-LHS101 0 LANDSCAPE HARDSCAPE PLAN WALL POINT TABLES 282 BT120-LHS102 0 LANDSCAPE HARDSCAPE BOULDER AND COBBLE POINT TABLES 283 BT120-LHS103 0 LANDSCAPE HARDSCAPE BOULDER AND COBBLE POINT TABLES 284 BT120-LHS104 0 LANDSCAPE HARDSCAPE DETAILS CURVE TABLES 285 BT120-LHD101 0 LANDSCAPE HARDSCAPE DETAILS 286 BT120-LHD102 0 LANDSCAPE HARDSCAPE DETAILS 287 BT120-LHD103 0 LANDSCAPE HARDSCAPE DETAILS 288 BT120-LHD104 0 LANDSCAPE HARDSCAPE DETAILS 289 BT120-LHD105 0 LANDSCAPE HARDSCAPE DETAILS 290 BT120-LHD106 0 LANDSCAPE HARDSCAPE DETAILS 291 BT120-LHD107 0 LANDSCAPE HARDSCAPE DETAILS 292 BT120-LHD108 0 LANDSCAPE HARDSCAPE DETAILS 293 BT120-LHD109 0 LANDSCAPE HARDSCAPE DETAILS 329 BT120-JCN201 0 SYSTEMS COMMUNICATION - LEGEND 330 BT120-JCP100 0 SYSTEMS SITE COMMUNICATIONS AREA PLAN 331 BT120-JCP104 0 SYSTEMS SITE COMMUNICATIONS GRADY STA 151+00 TO GRADY STA 156+50 332 BT120-JCP105 0 SYSTEMS SITE COMMUNICATIONS GRADY STA 156+50 TO GRADY STA 160+46.15 333 BT120-JCP106 0 SYSTEMS SITE COMMUNICATIONS LAKE STA 401+50 TO LAKE STA 405+50 334 BT120-JCP201 0 SYSTEMS SITE COMMUNICATION PLAN S RENTON TRANSIT CENTER 335 BT120-JCP202 0 SYSTEMS SITE COMMUNICATION PLAN S RENTON TRANSIT CENTER 336 BT120-JCP203 0 SYSTEMS SITE COMMUNICATION PLAN S RENTON TRANSIT CENTER 337 BT120-JCP204 0 SYSTEMS SITE COMMUNICATION PLAN S RENTON TRANSIT CENTER 338 BT120-JCP205 0 SYSTEMS SITE COMMUNICATION PLAN S RENTON TRANSIT CENTER 339 BT120-JCD201 0 SYSTEMS COMMUNICATION DETAILS 340 BT120-JCD202 0 SYSTEMS COMMUNICATION DETAILS 341 BT120-JCD203 0 SYSTEMS COMMUNICATIONS DETAIL 342 BT120-JFS201 0 SYSTEMS COMMUNICATION ONELINE DIAGRAM 343 BT120-JFS202 0 SYSTEMS COMMUNICATION ONELINE DIAGRAM 344 BT120-JFS203 0 SYSTEMS COMMUNICATION ONELINE DIAGRAM 294 BT120-LPP100 0 LANDSCAPE PLANTING PLAN AREA PLAN AND GENERAL NOTES 295 BT120-LPP101 0 LANDSCAPE PLANTING PLAN RAINIER STA 200+00 TO RAINIER STA 204+00 296 BT120-LPP102 0 LANDSCAPE PLANTING PLAN RAINIER STA 204+00 TO RAINIER STA 208+50 297 BT120-LPP103 0 LANDSCAPE PLANTING PLAN RAINIER STA 208+50 TO RAINIER STA 212+42.13 298 BT120-LPP104 0 LANDSCAPE PLANTING PLAN GRADY STA 151+00 TO GRADY STA 156+50 299 BT120-LPP105 0 LANDSCAPE PLANTING PLAN GRADY STA 156+50 TO GRADY STA 160+46.15 300 BT120-LPP106 0 LANDSCAPE PLANTING PLAN LAKE STA 401+50 TO LAKE STA 405+50 301 BT120-LPP201 0 LANDSCAPE PLANTING PLAN S RENTON TRANSIT CENTER 302 BT120-LPP202 0 LANDSCAPE PLANTING PLAN S RENTON TRANSIT CENTER 303 BT120-LPP203 0 LANDSCAPE PLANTING PLAN S RENTON TRANSIT CENTER 304 BT120-LPP204 0 LANDSCAPE PLANTING PLAN S RENTON TRANSIT CENTER 305 BT120-LPP205 0 LANDSCAPE PLANTING PLAN S RENTON TRANSIT CENTER 306 BT120-LPS101 0 LANDSCAPE PLANTING SCHEDULE LEGEND, NOTES & ABBREVIATIONS 307 BT120-LPD101 0 LANDSCAPE PLANTING DETAILS 308 BT120-LRP100 0 LANDSCAPE IRRIGATION PLAN AREA PLAN AND GENERAL NOTES 309 BT120-LRN101 0 LANDSCAPE IRRIGATION NOTES S RENTON TRANSIT CENTER 310 BT120-LRP101 0 LANDSCAPE IRRIGATION PLAN RAINIER STA 200+00 TO RAINIER STA 204+00 311 BT120-LRP102 0 LANDSCAPE IRRIGATION PLAN RAINIER STA 204+00 TO RAINIER STA 208+50 312 BT120-LRP103 0 LANDSCAPE IRRIGATION PLAN RAINIER STA 208+50 TO RAINIER STA 212+42.13 313 BT120-LRP104 0 LANDSCAPE IRRIGATION PLAN GRADY STA 151+00 TO GRADY STA 156+50 314 BT120-LRP105 0 LANDSCAPE IRRIGATION PLAN GRADY STA 156+50 TO GRADY STA 160+46.15 315 BT120-LRP106 0 LANDSCAPE IRRIGATION PLAN LAKE STA 401+50 TO LAKE STA 405+50 316 BT120-LRP201 0 LANDSCAPE IRRIGATION PLAN S RENTON TRANSIT CENTER 317 BT120-LRP202 0 LANDSCAPE IRRIGATION PLAN S RENTON TRANSIT CENTER 318 BT120-LRP203 0 LANDSCAPE IRRIGATION PLAN S RENTON TRANSIT CENTER 319 BT120-LRP204 0 LANDSCAPE IRRIGATION PLAN S RENTON TRANSIT CENTER 320 BT120-LRP205 0 LANDSCAPE IRRIGATION PLAN S RENTON TRANSIT CENTER 321 BT120-LRD101 0 LANDSCAPE IRRIGATION PLAN S RENTON TRANSIT CENTER 322 BT120-LRD102 0 LANDSCAPE IRRIGATION DETAILS S RENTON TRANSIT CENTER 323 BT120-LRD103 0 LANDSCAPE IRRIGATION DETAILS S RENTON TRANSIT CENTER 324 BT120-LTS101 0 LANDSCAPE TREE INVENTORY TABLE 325 BT120-LTD101 0 LANDSCAPE TREE PROTECTION DETAILS 326 BT120-ESP204 0 ELECTRICAL SITE PLAN - YARD TO GANTRY S RENTON TRANSIT CENTER 327 BT120-ESV201 0 ELECTRICAL DUCT BANK PROFILES S. RENTON TRANSIT CENTER 328 BT120-EPD120 0 ELECTRICAL DETAILS S RENTON TRANSIT CENTER 238 BT120-TSN101 0 TRAFFIC SIGNAL LEGEND 239 BT120-TSD101 0 TRAFFIC SIGNALIZATION DETAILS HARDIE AVE SW & RAINIER AVE S 240 BT120-TSD102 0 TRAFFIC SIGNAL DETAILS HARDIE AVE SW & RAINIER AVE S 241 BT120-TSS101 0 TRAFFIC SIGNAL SCHEDULES HARDIE AVE SW & RAINIER AVE S 242 BT120-TSS102 0 TRAFFIC SIGNAL SCHEDULES HARDIE AVE SW & RAINIER AVE S 243 BT120-TSS103 0 TRAFFIC SIGNAL SCHEDULES HARDIE AVE SW & RAINIER AVE S 244 BT120-TSS104 0 TRAFFIC SIGNAL SCHEDULES HARDIE AVE SW & RAINIER AVE S 245 BT120-TSD103 0 TRAFFIC SIGNAL DETAILS S GRADY WAY & LAKE AVE S 246 BT120-TSS105 0 TRAFFIC SIGNAL SCHEDULES S GRADY WAY & LAKE AVE S 247 BT120-TSS106 0 TRAFFIC SIGNAL SCHEDULES S GRADY WAY & LAKE AVE S 248 BT120-TSD104 0 TRAFFIC SIGNALIZATION DETAILS RAINIER AVE S & S GRADY WAY 249 BT120-TMN101 0 TRAFFIC CONTROL NOTES 250 BT120-TMP101 0 TRAFFIC CONTROL PLAN RAINIER AVE S 251 BT120-TMP102 0 TRAFFIC CONTROL PLAN RAINIER AVE S 252 BT120-TMP103 0 TRAFFIC CONTROL PLAN RAINIER AVE S 253 BT120-TMP104 0 TRAFFIC CONTROL PLAN RAINIER AVE S 254 BT120-TMP105 0 TRAFFIC CONTROL PLAN LAKE AVE S 255 BT120-TMP106 0 TRAFFIC CONTROL PLAN LAKE AVE S 256 BT120-TMP107 0 TRAFFIC CONTROL PLAN S GRADY WAY 257 BT120-TMP108 0 TRAFFIC CONTROL PLAN S GRADY WAY 258 BT120-TMP109 0 TRAFFIC CONTROL PLAN S GRADY WAY 259 BT120-TMP110 0 TRAFFIC CONTROL PLAN S GRADY WAY 260 BT120-TMP111 0 TRAFFIC CONTROL PLAN S GRADY WAY 261 BT120-TMP112 0 TRAFFIC CONTROL PLAN S GRADY WAY 262 BT120-TMP113 0 TRAFFIC CONTROL PLAN S GRADY WAY 263 BT120-TMP114 0 TRAFFIC CONTROL PLAN S GRADY WAY 264 BT120-TMP115 0 TRAFFIC CONTROL PLAN S GRADY WAY 265 BT120-TDP101 0 TRAFFIC DETOUR PLAN S GRADY WAY 269 BT120-SWP101 0 STRUCTURAL RETAINING WALL PLAN AND PROFILE 270 BT120-SWP102 0 STRUCTURAL RETAINING WALL PLAN AND PROFILE 266 BT120-TIP101 0 TRAFFIC INTELLIGENT TRANSPORTATION SYSTEMS PLAN RAINIER AVE S & HARDIE AVE SW 267 BT120-TID101 0 TRAFFIC INTELLIGENT TRANSPORTATION SYSTEMS DETAILS RAINIER AVE S & HARDIE AVE SW 268 BT120-TID102 0 TRAFFIC INTELLIGENT TRANSPORTATION SYSTEMS DETAILS RAINIER AVE S & HARDIE AVE SW LANDSCAPE SHT. No. DWG. No.TITLEREV SHT. No. DWG. No.TITLEREV STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL INDEX OF DRAWINGS BT120-GZI003 BT120 E. GOLLER E. GOLLER L. GILBERT J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 12 / 0 4 / 2 4 | 8 : 2 6 A M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z I 0 0 1 - 0 0 6 . D W G S1-BT120-GZI001-006 FACILITY ID: Xrefs: xBRT-CUD05-TB22x34 xS1-BT120-GZI001 GB-SEAL-JKH53550 SOUTH RENTON TRANSIT CENTER - BOOK 1 OF 3 SYSTEMSHARDSCAPE PLANTING IRRIGATION TREE INVENTORY AND PROTECTION ELECTRICAL COMMUNICATION TRAFFIC SIGNALS MAINTENANCE OF TRAFFIC STRUCTURAL MAINTENANCE OF TRAFFIC SIGNALS TRAFFIC LANDSCAPE (CONT'D) ITS 12/06/2024 0004 RTA/CN 0205-24 345 BT120-SZN001 0 STRUCTURE GENERAL STRUCTURAL NOTES 346 BT120-SZN002 0 STRUCTURE GENERAL STRUCTURAL NOTES 347 BT120-SZN003 0 STRUCTURE GENERAL STRUCTURAL NOTES 348 BT120-SZP001 0 STRUCTURE LOAD MAPS, DIAGRAMS, AND SCHEDULES 349 BT120-SFP001 0 STRUCTURE OVERALL SITE PLAN 350 BT120-SFP212 0 STRUCTURE FOUNDATION PLAN CANOPY - SECTOR A 351 BT120-SFP213 0 STRUCTURE FOUNDATION PLAN CANOPY - SECTOR B 352 BT120-SFP214 0 STRUCTURE FOUNDATION PLAN CANOPY - SECTOR C 353 BT120-SFP215 0 STRUCTURE FOUNDATION PLAN CANOPY - SECTOR D 354 BT120-SFP221 0 STRUCTURE OVERALL FOUNDATION PLAN CORE FACILITY 355 BT120-SFP231 0 STRUCTURE OVERALL FOUNDATION PLAN CHARGING GANTRY 356 BT120-SFP241 0 STRUCTURE OVERALL FOUNDATION PLAN BEB EQUIPMENT YARD 357 BT120-SGP312 0 STRUCTURE LEVEL 2 FRAMING PLAN CANOPY - SECTOR A 358 BT120-SGP313 0 STRUCTURE LEVEL 2 FRAMING PLAN CANOPY - SECTOR B 359 BT120-SGP314 0 STRUCTURE LEVEL 2 FRAMING PLAN CANOPY - SECTOR C 360 BT120-SGP321 0 STRUCTURE MISCELLANEOUS STEEL OVERALL FRAMING PLAN CORE FACILITY 361 BT120-SGP331 0 STRUCTURE LEVEL 2 OVERALL FRAMING PLAN CHARGING GANTRY 362 BT120-SGP341 0 STRUCTURE ROOF OVERALL FRAMING PLAN BEB EQUIPMENT YARD 363 BT120-SGP421 0 STRUCTURE LOW ROOF OVERALL FRAMING PLAN CORE FACILITY 364 BT120-SGP431 0 STRUCTURE LEVEL 3 OVERALL FRAMING PLAN CHARGING GANTRY 365 BT120-SGP521 0 STRUCTURE HIGH ROOF OVERALL FRAMING PLAN CORE FACILITY 366 BT120-SGE111 0 STRUCTURE FRAMING ELEVATIONS CANOPY 367 BT120-SGE121 0 STRUCTURE FRAMING ELEVATIONS CORE FACILITY 368 BT120-SGE122 0 STRUCTURE FRAMING ELEVATIONS CORE FACILITY 369 BT120-SGE123 0 STRUCTURE FRAMING ELEVATIONS CORE FACILITY 370 BT120-SGE124 0 STRUCTURE FRAMING ELEVATIONS CORE FACILITY 371 BT120-SGE131 0 STRUCTURE FRAMING ELEVATIONS CHARGING GANTRY 372 BT120-SGE141 0 STRUCTURE FRAMING ELEVATIONS BEB EQUIPMENT YARD 373 BT120-SGY401 0 STRUCTURE TYPICAL FOUNDATION DETAILS 1 374 BT120-SGY402 0 STRUCTURE TYPICAL FOUNDATION DETAILS 2 375 BT120-SGY403 0 STRUCTURE TYPICAL FOUNDATION DETAILS 3 376 BT120-SGY404 0 STRUCTURE TYPICAL CONCRETE DETAILS 1 377 BT120-SGY405 0 STRUCTURE TYPICAL CONCRETE DETAILS 2 378 BT120-SGY406 0 STRUCTURE TYPICAL STEEL COLUMN DETAILS 379 BT120-SGY407 0 STRUCTURE TYPICAL STEEL BEAM DETAILS 1 380 BT120-SGY408 0 STRUCTURE TYPICAL STEEL BEAM DETAILS 2 381 BT120-SGY409 0 STRUCTURE TYPICAL STEEL BEAM DETAILS 3 382 BT120-SGY410 0 STRUCTURE TYPICAL ROOF DECK DETAILS 383 BT120-SGY411 0 STRUCTURE TYPICAL BRACED FRAME AND MOMENT FRAME DETAILS 1 384 BT120-SGY412 0 STRUCTURE TYPICAL BRACED FRAME AND MOMENT FRAME DETAILS 2 385 BT120-SGD111 0 STRUCTURE SECTIONS AND DETAILS CANOPY 386 BT120-SGD112 0 STRUCTURE SECTIONS AND DETAILS CANOPY 387 BT120-SGD113 0 STRUCTURE SECTIONS AND DETAILS CANOPY 388 BT120-SGD121 0 STRUCTURE SECTIONS AND DETAILS CORE FACILITY 389 BT120-SGD122 0 STRUCTURE SECTIONS AND DETAILS CORE FACILITY 390 BT120-SGD123 0 STRUCTURE SECTIONS AND DETAILS CORE FACILITY 391 BT120-SGD131 0 STRUCTURE SECTIONS AND DETAILS CHARGING GANTRY 392 BT120-SGD132 0 STRUCTURE SECTIONS AND DETAILS CHARGING GANTRY 393 BT120-SGD133 0 STRUCTURE SECTIONS AND DETAILS CHARGING GANTRY 394 BT120-SGD161 0 STRUCTURE SECTIONS AND DETAILS RETAINING WALL 395 BT120-SGD162 0 STRUCTURE SECTIONS AND DETAILS WINDSCREEN 1 BT120-GZT001 0 GENERAL COVER SHEET 2 BT120-GZI001 0 GENERAL INDEX OF DRAWINGS 3 BT120-GZI002 0 GENERAL INDEX OF DRAWINGS 4 BT120-GZI003 0 GENERAL INDEX OF DRAWINGS 5 BT120-GZI004 0 GENERAL INDEX OF DRAWINGS 6 BT120-GZI005 0 GENERAL INDEX OF DRAWINGS 7 BT120-GZI006 0 GENERAL INDEX OF DRAWINGS 8 BT120-GZI701 0 GENERAL INDEX OF DRAWINGS SR 167 9 BT120-GZK000 0 GENERAL PROJECT LOCATION ID PLAN 10 BT120-GZK001 0 GENERAL KEY PLAN 11 BT120-GZN001 0 GENERAL ABBREVIATIONS 12 BT120-GZN002 0 GENERAL ABBREVIATIONS 13 BT120-GZN003 0 GENERAL ABBREVIATIONS 14 BT120-GZN004 0 GENERAL ABBREVIATIONS 15 BT120-GZN005 0 GENERAL ABBREVIATIONS 16 BT120-GZN006 0 GENERAL SYMBOLS AND LEGEND 17 BT120-GZN007 0 GENERAL SYMBOLS AND LEGEND 396 BT120-SGD163 0 STRUCTURE PLANS AND ELEVATIONS PARATRANSIT SHELTER 1 397 BT120-SGD164 0 STRUCTURE SECTIONS AND DETAILS PARATRANSIT SHELTER 2 398 BT120-AZN001 0 ARCHITECTURE MATERIAL ABBREVIATIONS TRANSIT CENTER 399 BT120-ASP201 0 ARCHITECTURE SITE PLAN TRANSIT CENTER 400 BT120-ASZ201 0 ARCHITECTURE LIFE SAFETY PLAN AND CODE INFORMATION TRANSIT CENTER 401 BT120-APP211 0 ARCHITECTURE OVERALL PLAN PLATFORM 402 BT120-APP212 0 ARCHITECTURE PLATFORM PLAN PLATFORM - SECTOR A 403 BT120-APP213 0 ARCHITECTURE PLATFORM PLAN PLATFORM - SECTOR B 404 BT120-APP214 0 ARCHITECTURE PLATFORM PLAN PLATFORM - SECTOR C 405 BT120-APP215 0 ARCHITECTURE PLATFORM PLAN PLATFORM - SECTOR D 406 BT120-APP216 0 ARCHITECTURE ENLARGED SHELTER PLANS PLATFORM - SECTOR D 407 BT120-ARP311 0 ARCHITECTURE OVERALL ROOF PLAN PLATFORM 408 BT120-ARP312 0 ARCHITECTURE ENLARGED PLATFORM ROOF PLAN PLATFORM - SECTOR A 409 BT120-ARP313 0 ARCHITECTURE ENLARGED PLATFORM ROOF PLAN PLATFORM - SECTOR B 410 BT120-ARP314 0 ARCHITECTURE ENLARGED PLATFORM ROOF PLAN PLATFORM - SECTOR C 411 BT120-APD101 0 ARCHITECTURE ENLARGED PLATFORM PLANS & ELEVATION PLATFORM 412 BT120-ANP211 0 ARCHITECTURE OVERALL SIGNAGE PLAN PLATFORM 413 BT120-ANP212 0 ARCHITECTURE SIGNAGE PLAN PLATFORM - SECTOR A 414 BT120-ANP213 0 ARCHITECTURE SIGNAGE PLAN PLATFORM - SECTOR B 415 BT120-ANP214 0 ARCHITECTURE SIGNAGE PLAN PLATFORM - SECTOR C 416 BT120-ANP215 0 ARCHITECTURE SIGNAGE PLAN PLATFORM - SECTOR D 417 BT120-AEE811 0 ARCHITECTURE EXTERIOR ELEVATIONS PLATFORM - END 418 BT120-AEE812 0 ARCHITECTURE EXTERIOR ELEVATIONS PLATFORM - BUS BAY 1 419 BT120-AEE813 0 ARCHITECTURE EXTERIOR ELEVATIONS PLATFORM - BUS BAY 2 AND 8 420 BT120-AEE814 0 ARCHITECTURE EXTERIOR ELEVATIONS PLATFORM - BUS BAY 3 421 BT120-AEE815 0 ARCHITECTURE EXTERIOR ELEVATIONS PLATFORM - BUS BAY 6 AND 7 422 BT120-AEE816 0 ARCHITECTURE EXTERIOR ELEVATIONS PLATFORM - BUS BAY 4 423 BT120-AEX711 0 ARCHITECTURE CROSS SECTIONS PLATFORM 424 BT120-AEX712 0 ARCHITECTURE LONGITUDINAL SECTIONS PLATFORM 425 BT120-AEX713 0 ARCHITECTURE SECTIONS PLATFORM 426 BT120-AEX714 0 ARCHITECTURE SHELTER SECTION & DETAILS PLATFORM 427 BT120-AED900 0 ARCHITECTURE CANOPY DETAILS PLATFORM 428 BT120-AED901 0 ARCHITECTURE WINDSCREEN DETAILS PLATFORM 429 BT120-AED902 0 ARCHITECTURE WINDSCREEN DETAILS PLATFORM 430 BT120-AED903 0 ARCHITECTURE CONDUIT RACEWAY DETAILS PLATFORM 431 BT120-AED904 0 ARCHITECTURE CONDUIT RACEWAY DETAILS PLATFORM 432 BT120-AED912 0 ARCHITECTURE CLERESTORY DETAILS PLATFORM 433 BT120-AED914 0 ARCHITECTURE SIGNAGE DETAILS PLATFORM 434 BT120-AED915 0 ARCHITECTURE SIGNAGE DETAILS PLATFORM 435 BT120-AED916 0 ARCHITECTURE CANOPY DETAILS - PLATFORM PLATFORM 436 BT120-ACP211 0 ARCHITECTURE REFLECTED CEILING PLAN PLATFORM 437 BT120-ACP212 0 ARCHITECTURE REFLECTED CEILING PLAN PLATFORM - SECTOR A 438 BT120-ACP213 0 ARCHITECTURE REFLECTED CEILING PLAN PLATFORM - SECTOR B 439 BT120-ACP214 0 ARCHITECTURE REFLECTED CEILING PLAN PLATFORM - SECTOR C 440 BT120-APP221 0 ARCHITECTURE FLOOR PLAN CORE FACILITY 441 BT120-APD222 0 ARCHITECTURE ENLARGED FLOOR PLAN CORE FACILITY - SECTOR E 442 BT120-APD223 0 ARCHITECTURE ENLARGED FLOOR PLAN CORE FACILITY - SECTOR F 443 BT120-APD224 0 ARCHITECTURE ENLARGED FLOOR PLAN CORE FACILITY - SECTOR G 444 BT120-APD225 0 ARCHITECTURE ENLARGED FLOOR PLAN CORE FACILITY - SECTOR H 445 BT120-ARP321 0 ARCHITECTURE ROOF PLAN CORE FACILITY 446 BT120-AEE821 0 ARCHITECTURE EXTERIOR ELEVATIONS CORE FACILITY 447 BT120-AEE822 0 ARCHITECTURE EXTERIOR ELEVATIONS CORE FACILITY 448 BT120-AIX721 0 ARCHITECTURE BUILDING SECTIONS I CORE FACILITY 449 BT120-AIX722 0 ARCHITECTURE BUILDING SECTIONS II CORE FACILITY 450 BT120-AIX723 0 ARCHITECTURE BUILDING SECTIONS III CORE FACILITY 451 BT120-AIX724 0 ARCHITECTURE BUILDING SECTIONS IV CORE FACILITY 452 BT120-AIX725 0 ARCHITECTURE WALL SECTIONS I CORE FACILITY 453 BT120-AIE821 0 ARCHITECTURE INTERIOR ELEVATIONS CORE FACILITY - SECURITY ROOM 454 BT120-AIE822 0 ARCHITECTURE INTERIOR ELEVATIONS CORE FACILITY - LACTATION ROOM, JANITOR ROOM 455 BT120-AIE823 0 ARCHITECTURE INTERIOR ELEVATIONS CORE FACILITY - COMFORT STATIONS 456 BT120-AIE824 0 ARCHITECTURE INTERIOR ELEVATIONS CORE FACILITY - COMFORT STATIONS 457 BT120-ACP221 0 ARCHITECTURE OVERALL REFLECTED CEILING PLAN CORE FACILITY 458 BT120-ACP222 0 ARCHITECTURE REFLECTED CEILING PLAN CORE FACILITY - SECURITY ROOM 459 BT120-ACP223 0 ARCHITECTURE REFLECTED CEILING PLAN CORE FACILITY - PUBLIC FACILITY 460 BT120-AED905 0 ARCHITECTURE MISC DETAILS CORE FACILITY 461 BT120-AED906 0 ARCHITECTURE EXTERIOR DETAILS CORE FACILITY 462 BT120-AED907 0 ARCHITECTURE MISC DETAILS CORE FACILITY 463 BT120-AED908 0 ARCHITECTURE MISC DETAILS CORE FACILITY SHT. No. DWG. No.TITLEREV SHT. No. DWG. No.TITLEREV STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL INDEX OF DRAWINGS BT120-GZI004 BT120 E. GOLLER E. GOLLER L. GILBERT J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 12 / 0 4 / 2 4 | 8 : 2 6 A M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z I 0 0 1 - 0 0 6 . D W G S1-BT120-GZI001-006 FACILITY ID: Xrefs: xBRT-CUD05-TB22x34 xS1-BT120-GZI001 GB-SEAL-JKH53550 SOUTH RENTON TRANSIT CENTER - BOOK 2 OF 3 STRUCTURAL STRUCTURAL (CONT'D)GENERAL ARCHITECTURAL 12/06/2024 0005 RTA/CN 0205-24 464 BT120-AED909 0 ARCHITECTURE PLANTER BOX DETAIL, MISC CORE FACILITY 465 BT120-AES910 0 ARCHITECTURE PARTITION TYPES CORE FACILITY 466 BT120-AES911 0 ARCHITECTURE TRANSLUCENT WINDOW TYPES CORE FACILITY 467 BT120-AES912 0 ARCHITECTURE SCHEDULES CORE FACILITY 468 BT120-AID909 0 ARCHITECTURE DETAILS CORE FACILITY 469 BT120-APP231 0 ARCHITECTURE FLOOR PLAN GANTRY 470 BT120-AEE831 0 ARCHITECTURE OVERALL EXTERIOR ELEVATIONS GANTRY 471 BT120-AEE832 0 ARCHITECTURE EXTERIOR ELEVATIONS GANTRY 472 BT120-AEE833 0 ARCHITECTURE EXTERIOR ELEVATIONS GANTRY 473 BT120-AEE834 0 ARCHITECTURE EXTERIOR ELEVATIONS GANTRY 474 BT120-ACP231 0 ARCHITECTURE REFLECTED CEILING PLAN GANTRY 475 BT120-AED910 0 ARCHITECTURE GANTRY DETAILS GANTRY 476 BT120-APP241 0 ARCHITECTURE FLOOR PLAN BEB EQUIPMENT YARD 477 BT120-ARP341 0 ARCHITECTURE ROOF PLAN BEB EQUIPMENT YARD 478 BT120-AEE841 0 ARCHITECTURE EXTERIOR ELEVATIONS BEB EQUIPMENT YARD 479 BT120-ACP241 0 ARCHITECTURE REFLECTED CEILING PLAN BEB EQUIPMENT YARD 480 BT120-AED913 0 ARCHITECTURE MISC DETAILS BEB EQUIPMENT YARD 481 BT120-APP251 0 ARCHITECTURE FLOOR PLAN GENERATOR PAD 482 BT120-AEE851 0 ARCHITECTURE EXTERIOR ELEVATIONS GENERATOR PAD 483 BT120-APP261 0 ARCHITECTURE FLOOR PLAN REFUSE AND RECYCLING AREA 484 BT120-AEE861 0 ARCHITECTURE EXTERIOR ELEVATIONS REFUSE AND RECYCLING AREA 485 BT120-AID900 0 ARCHITECTURE DETAILS TRANSIT CENTER 486 BT120-AID901 0 ARCHITECTURE DETAILS TRANSIT CENTER 487 BT120-AID902 0 ARCHITECTURE DETAILS TRANSIT CENTER 488 BT120-AID903 0 ARCHITECTURE DETAILS TRANSIT CENTER 489 BT120-AID904 0 ARCHITECTURE DETAILS TRANSIT CENTER 490 BT120-AID905 0 ARCHITECTURE DETAILS TRANSIT CENTER 491 BT120-AID906 0 ARCHITECTURE DETAILS TRANSIT CENTER 492 BT120-AID907 0 ARCHITECTURE DETAILS TRANSIT CENTER 493 BT120-AID908 0 ARCHITECTURE DETAILS TRANSIT CENTER 494 BT120-AID910 0 ARCHITECTURE DETAILS TRANSIT CENTER 495 BT120-AID911 0 ARCHITECTURE DETAILS TRANSIT CENTER 496 BT120-AID912 0 ARCHITECTURE DETAILS TRANSIT CENTER 497 BT120-AID913 0 ARCHITECTURE DETAILS TRANSIT CENTER 498 BT120-MPN001 0 MECHANICAL GENERAL NOTES AND LEGEND 499 BT120-MPP121 0 MECHANICAL UNDERGROUND PLAN CORE FACILITY 500 BT120-MPP221 0 MECHANICAL FLOOR PLAN CORE FACILITY 501 BT120-MPP222 0 MECHANICAL ENLARGED FLOOR PLAN CORE FACILITY 502 BT120-MPP321 0 MECHANICAL ROOF PLAN CORE FACILITY 503 BT120-MPS001 0 MECHANICAL RISER DIAGRAMS WATER CORE FACILITY 504 BT120-MPS002 0 MECHANICAL RISER DIAGRAMS WASTE CORE FACILITY 505 BT120-MPS003 0 MECHANICAL SCHEDULES 506 BT120-MPD001 0 MECHANICAL DETAILS 507 BT120-MPD002 0 MECHANICAL DETAILS 508 BT120-MHN001 0 MECHANICAL LEGEND, ABBREVIATIONS AND ENERGY CODES CORE FACILITY 509 BT120-MHN002 0 MECHANICAL CONSTRUCTION, GENERAL AND KEY NOTES CORE FACILITY 510 BT120-MHP221 0 MECHANICAL FLOOR PLAN - BELOW 8' AFF CORE FACILITY 511 BT120-MHP222 0 MECHANICAL FLOOR PLAN - ABOVE 8' AFF CORE FACILITY 512 BT120-MHS001 0 MECHANICAL SCHEMATICS, DIAGRAMS CORE FACILITY 513 BT120-MHS002 0 MECHANICAL SCHEDULES CORE FACILITY 514 BT120-MHS003 0 MECHANICAL SCHEDULES CORE FACILITY 515 BT120-MHS005 0 MECHANICAL BMS POINTS LIST CORE FACILITY 516 BT120-MHS006 0 MECHANICAL BMS SYSTEM ARCHITECTURE CORE FACILITY 517 BT120-MHS007 0 MECHANICAL CONTROLS SCHEDULE CORE FACILITY 518 BT120-MHS010 0 MECHANICAL CONTROLS SCHEDULE CORE FACILITY 519 BT120-MHD001 0 MECHANICAL DETAILS CORE FACILITY 520 BT120-EPN001 0 ELECTRICAL SYMBOLS AND LEGEND 521 BT120-EPN002 0 ELECTRICAL SYMBOLS AND LEGEND 522 BT120-EPN003 0 ELECTRICAL GENERAL NOTES AND MOUNTING 523 BT120-EPN004 0 ELECTRICAL PROJECT KEYNOTE LIST 524 BT120-ESP101 0 ELECTRICAL SITE PLAN SOUTH RENTON TRANSIT CENTER 525 BT120-ESP401 0 ELECTRICAL SITE PLAN - ENLARGED SOUTH RENTON TRANSIT CENTER 526 BT120-ELP211 0 ELECTRICAL LIGHTING PLAN - OVERALL CANOPY 527 BT120-ELP212 0 ELECTRICAL LIGHTING PLAN - SECTOR A CANOPY 528 BT120-ELP213 0 ELECTRICAL LIGHTING PLAN - SECTOR B CANOPY 529 BT120-ELP214 0 ELECTRICAL LIGHTING PLAN - SECTOR C CANOPY 530 BT120-EPP211 0 ELECTRICAL POWER PLAN - CANOPY OVERALL CANOPY 531 BT120-EPP212 0 ELECTRICAL POWER PLAN - SECTOR A CANOPY 532 BT120-EPP213 0 ELECTRICAL POWER PLAN - SECTOR B CANOPY 533 BT120-EPP214 0 ELECTRICAL POWER PLAN - SECTOR C CANOPY 534 BT120-EPP215 0 ELECTRICAL POWER PLAN - SECTOR D CANOPY 535 BT120-EPE212 0 ELECTRICAL POWER ELEVATION - SECTOR A CANOPY 536 BT120-EPE213 0 ELECTRICAL POWER ELEVATION - SECTOR B CANOPY 537 BT120-EPE214 0 ELECTRICAL POWER ELEVATION - SECTOR C CANOPY 538 BT120-ELP221 0 ELECTRICAL LIGHTING PLAN - CORE FACILITY CORE FACILITY 539 BT120-EPP221 0 ELECTRICAL POWER PLAN - CORE FACILITY CORE FACILITY 540 BT120-EPP222 0 ELECTRICAL POWER PLAN - SECTOR F CORE FACILITY 541 BT120-EPP223 0 ELECTRICAL POWER PLAN - ENLARGED ELECTRICAL ROOM CORE FACILITY 542 BT120-EPE221 0 ELECTRICAL POWER ELEVATIONS - ELECTRICAL ROOM CORE FACILITY 543 BT120-ELP231 0 ELECTRICAL LIGHTING PLAN BEB CHARGING GANTRY 544 BT120-EPP231 0 ELECTRICAL POWER PLAN AND GROUNDING PLAN BEB CHARGING GANTRY 545 BT120-ELP241 0 ELECTRICAL LIGHTING PLAN BEB EQUIPMENT YARD 546 BT120-EPP241 0 ELECTRICAL POWER PLAN BEB EQUIPMENT YARD 547 BT120-EPP242 0 ELECTRICAL UNDERGROUND CONDUIT BEB EQUIPMENT YARD 548 BT120-EGS101 0 ELECTRICAL GROUNDING DIAGRAM - SECTOR A CANOPY 549 BT120-EGS102 0 ELECTRICAL GROUNDING DIAGRAM - CORE FACILITY CORE FACILITY 550 BT120-EGS103 0 ELECTRICAL GROUNDING PLAN BEB CHARGING GANTRY 551 BT120-EGS104 0 ELECTRICAL GROUNDING PLAN BEB EQUIPMENT YARD 552 BT120-EPD101 0 ELECTRICAL DETAILS SOUTH RENTON TRANSIT CENTER 553 BT120-EPD102 0 ELECTRICAL DETAILS SOUTH RENTON TRANSIT CENTER 554 BT120-EPD103 0 ELECTRICAL DETAILS SOUTH RENTON TRANSIT CENTER 555 BT120-EPD104 0 ELECTRICAL DETAILS SOUTH RENTON TRANSIT CENTER 556 BT120-EPD105 0 ELECTRICAL DETAILS SOUTH RENTON TRANSIT CENTER 557 BT120-EPD106 0 ELECTRICAL DETAILS SOUTH RENTON TRANSIT CENTER 558 BT120-EPD107 0 ELECTRICAL DETAILS SOUTH RENTON TRANSIT CENTER 559 BT120-EPD108 0 ELECTRICAL DETAILS SOUTH RENTON TRANSIT CENTER 560 BT120-EPD109 0 ELECTRICAL DETAILS SOUTH RENTON TRANSIT CENTER 561 BT120-EPD110 0 ELECTRICAL DETAILS SOUTH RENTON TRANSIT CENTER 562 BT120-EPD111 0 ELECTRICAL DETAILS SOUTH RENTON TRANSIT CENTER 563 BT120-EPD112 0 ELECTRICAL DETAILS SOUTH RENTON TRANSIT CENTER 564 BT120-EPS101 0 ELECTRICAL BEP ONE-LINE SOUTH RENTON TRANSIT CENTER 565 BT120-EPS102 0 ELECTRICAL CORE FACILITES ONE-LINE SOUTH RENTON TRANSIT CENTER 566 BT120-EPS103 0 ELECTRICAL BEB CHARGING BLOCK DIAGRAM SOUTH RENTON TRANSIT CENTER 567 BT120-EPS104 0 ELECTRICAL SITE LIGHTING WIRING DIAGRAM SOUTH RENTON TRANSIT CENTER 568 BT120-EPS110 0 ELECTRICAL KCM PANEL SCHEDULES SOUTH RENTON TRANSIT CENTER 569 BT120-EPS111 0 ELECTRICAL KCM PANEL SCHEDULES SOUTH RENTON TRANSIT CENTER 570 BT120-EPS112 0 ELECTRICAL ST PANEL SCHEDULES SOUTH RENTON TRANSIT CENTER 571 BT120-EPS113 0 ELECTRICAL ST PANEL SCHEDULES SOUTH RENTON TRANSIT CENTER 572 BT120-EPS114 0 ELECTRICAL ST PANEL SCHEDULES SOUTH RENTON TRANSIT CENTER 573 BT120-EPS115 0 ELECTRICAL ST PANEL SCHEDULES SOUTH RENTON TRANSIT CENTER 574 BT120-EPS116 0 ELECTRICAL ST PANEL SCHEDULES SOUTH RENTON TRANSIT CENTER 575 BT120-EPS117 0 ELECTRICAL ST PANEL SCHEDULES SOUTH RENTON TRANSIT CENTER 576 BT120-EPS120 0 ELECTRICAL CONNECTION SCHEDULE SOUTH RENTON TRANSIT CENTER 577 BT120-EPS121 0 ELECTRICAL CONDUIT AND CONDUCTOR SCHEDULE SOUTH RENTON TRANSIT CENTER 578 BT120-EPS122 0 ELECTRICAL CONDUIT AND CONDUCTOR SCHEDULE 2 SOUTH RENTON TRANSIT CENTER 579 BT120-EPS123 0 ELECTRICAL CONDUIT AND CONDUCTOR SCHEDULE 3 SOUTH RENTON TRANSIT CENTER 580 BT120-EPS130 0 ELECTRICAL EQUIPMENT MATRIX SOUTH RENTON TRANSIT CENTER 581 BT120-EPS131 0 ELECTRICAL EQUIPMENT MATRIX SOUTH RENTON TRANSIT CENTER 582 BT120-EPS132 0 ELECTRICAL EQUIPMENT MATRIX SOUTH RENTON TRANSIT CENTER 583 BT120-ELS101 0 ELECTRICAL LUMINAIRE SCHEDULE SOUTH RENTON TRANSIT CENTER 584 BT120-ELS102 0 ELECTRICAL LIGHTING CONTROL MATRIX SOUTH RENTON TRANSIT CENTER SHT. No. DWG. No.TITLEREV SHT. No. DWG. No.TITLEREV STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL INDEX OF DRAWINGS BT120-GZI005 BT120 E. GOLLER E. GOLLER L. GILBERT J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 12 / 0 4 / 2 4 | 8 : 2 6 A M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z I 0 0 1 - 0 0 6 . D W G S1-BT120-GZI001-006 FACILITY ID: Xrefs: xBRT-CUD05-TB22x34 xS1-BT120-GZI001 GB-SEAL-JKH53550 SOUTH RENTON TRANSIT CENTER - BOOK 2 OF 3 MECHANICAL ELECTRICALARCHITECTURAL (CONT'D) 12/06/2024 0006 RTA/CN 0205-24 585 BT120-JCN203 0 SYSTEMS COMMUNICATIONS NOTES 586 BT120-JCP206 0 SYSTEMS STRIDE BAY 1 COMMUNICATIONS PLAN 587 BT120-JCP207 0 SYSTEMS STRIDE BAY 2 AND 8 COMMUNICATIONS PLAN 588 BT120-JCP208 0 SYSTEMS KCM BAYS 3,6, AND 7 COMMUNICATIONS PLAN 589 BT120-JCP209 0 SYSTEMS KCM RAPID RIDE COMMUNICATIONS PLAN BAY 4 AND 5 590 BT120-JCP210 0 SYSTEMS STRIDE BAY 1 SHELTER COMMUNICATIONS RCP 591 BT120-JCP211 0 SYSTEMS KCM RAPID RIDE BAY 2 AND STRIDE BAY 8 592 BT120-JCP212 0 SYSTEMS KCM COMMUNICATIONS RCP BAYS 3,4,6, AND 7 593 BT120-JCE209 0 SYSTEMS STRIDE BAY AREA 1 COMMUNICATIONS ELEVATION 594 BT120-JCE210 0 SYSTEMS STRIDE LAYOVER COMMUNICATIONS ELEVATION 595 BT120-JCE211 0 SYSTEMS STRIDE BAY 8 COMMUNICATIONS ELEVATION 596 BT120-JCE212 0 SYSTEMS KCM BAY 2 COMMUNICATIONS ELEVATION 597 BT120-JCE213 0 SYSTEMS KCM BAY 7 COMMUNICATIONS ELEVATION 598 BT120-JCE214 0 SYSTEMS KCM BAY 6 COMMUNICATIONS ELEVATIONS 599 BT120-JCE215 0 SYSTEMS KCM BAYS 4 AND 5 COMMUNICATIONS ELEVATION 600 BT120-JCE216 0 SYSTEMS KCM BAY 3 COMMUNICATIONS ELEVATION 601 BT120-JCX210 0 SYSTEMS COMMUNICATIONS STRIDE BAY 1 SECTIONS 602 BT120-JCX211 0 SYSTEMS KCM COMMUNICATIONS SECTIONS 603 BT120-JCX212 0 SYSTEMS STRIDE BAY 2 AND 8 COMMUNICATIONS SECTIONS 604 BT120-JFS204 0 SYSTEMS SOUND TRANSIT BAY 1 RISER DIAGRAM 605 BT120-JFS205 0 SYSTEMS SOUND TRANSIT BAY 8 RISER DIAGRAM 606 BT120-JFS206 0 SYSTEMS SOUND TRANSIT OTHER BAYS RISER DIAGRAM 607 BT120-JFS207 0 SYSTEMS KCM BAY 2 RISER DIAGRAM 608 BT120-JFS208 0 SYSTEMS KCM OTHER BAYS RISER DIAGRAM 609 BT120-JCD204 0 SYSTEMS COMMUNICATIONS DETAILS 610 BT120-JCD205 0 SYSTEMS COMMUNICATIONS DETAILS 611 BT120-JCD206 0 SYSTEMS COMMUNICATIONS DETAILS 612 BT120-JCD207 0 SYSTEMS COMMUNICATIONS DETAILS 613 BT120-JCD208 0 SYSTEMS COMMUNICATIONS DETAILS 614 BT120-JCD209 0 SYSTEMS COMMUNICATIONS DETAILS 615 BT120-JCD210 0 SYSTEMS COMMUNICATIONS DETAILS 616 BT120-JCD211 0 SYSTEMS CCTV CAMERA DATA 617 BT120-JCN000 0 SYSTEMS SYMBOLS AND LEGEND TRANSIT CENTER 618 BT120-JCN001 0 SYSTEMS GENERAL NOTES TRANSIT CENTER 619 BT120-JCN002 0 SYSTEMS GENERAL NOTES TRANSIT CENTER 620 BT120-JCN003 0 SYSTEMS GENERAL NOTES TRANSIT CENTER 621 BT120-JCN004 0 SYSTEMS GENERAL NOTES TRANSIT CENTER 622 BT120-JCN005 0 SYSTEMS GENERAL NOTES TRANSIT CENTER 623 BT120-JCS006 0 SYSTEMS OUTLET AND MATRICES TRANSIT CENTER 624 BT120-JCP001 0 SYSTEMS SITE - OVERALL PLAN TRANSIT CENTER 625 BT120-JCP002 0 SYSTEMS SITE - ENLARGED PLAN TRANSIT CENTER 626 BT120-JCP220 0 SYSTEMS CORE FACILITY TELECOMMUNICATIONS PLAN TRANSIT CENTER 627 BT120-JCP221 0 SYSTEMS CORE FACILITY CONDUIT PLAN TRANSIT CENTER 628 BT120-JCP261 0 SYSTEMS TELECOM ROOM ENLARGED PLANS TRANSIT CENTER 629 BT120-JCE262 0 SYSTEMS TELECOM ROOM ST & KCM ELEVATIONS TRANSIT CENTER 630 BT120-JCE263 0 SYSTEMS TELECOM ROOM SERVICE PROVIDER ELEVATIONS TRANSIT CENTER 631 BT120-JCE264 0 SYSTEMS TELECOM ROOM OVERALL ELEVATIONS TRANSIT CENTER 632 BT120-JCE265 0 SYSTEMS TELECOM ROOM ISOMETRIC VIEW TRANSIT CENTER 633 BT120-JCD501 0 SYSTEMS INSTALLATION DETAILS TRANSIT CENTER 634 BT120-JCD502 0 SYSTEMS INSTALLATION DETAILS TRANSIT CENTER 635 BT120-JCD503 0 SYSTEMS INSTALLATION DETAILS TRANSIT CENTER 636 BT120-JCD504 0 SYSTEMS INSTALLATION DETAILS TRANSIT CENTER 637 BT120-JCD505 0 SYSTEMS INSTALLATION DETAILS TRANSIT CENTER 638 BT120-JCD506 0 SYSTEMS INSTALLATION DETAILS TRANSIT CENTER 639 BT120-JFS001 0 SYSTEMS BACKBONE SINGLE LINE TRANSIT CENTER 640 BT120-JCP003 0 SYSTEMS SITE - OVERALL PLAN TRANSIT CENTER 641 BT120-JCN051 0 SYSTEMS SYMBOLS AND LEGEND TRANSIT CENTER 642 BT120-JCP222 0 SYSTEMS FLOOR PLAN BUILDING PLAN 643 BT120-JCP223 0 SYSTEMS CONDUIT PLAN BUILDING PLAN 644 BT120-JCS051 0 SYSTEMS NETWORK RISER DIAGRAM 645 BT120-JCS052 0 SYSTEMS NETWORK RISER DIAGRAM 646 BT120-JCD551 0 SYSTEMS DETAILS 647 BT120-JCD552 0 SYSTEMS DETAILS 648 BT120-JCD553 0 SYSTEMS DETAILS 649 BT120-JCD554 0 SYSTEMS STANDARD DETAILS 650 BT120-JCD555 0 SYSTEMS STANDARD DETAILS SHT. No. DWG. No.TITLEREV SHT. No. DWG. No.TITLEREV STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL INDEX OF DRAWINGS BT120-GZI006 BT120 E. GOLLER E. GOLLER L. GILBERT J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 12 / 0 4 / 2 4 | 8 : 2 6 A M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z I 0 0 1 - 0 0 6 . D W G S1-BT120-GZI001-006 FACILITY ID: Xrefs: xBRT-CUD05-TB22x34 xS1-BT120-GZI001 GB-SEAL-JKH53550 SOUTH RENTON TRANSIT CENTER - BOOK 2 OF 3 SYSTEMS COMMUNICATION SECURITYSECURITY TELECOM 12/06/2024 0007 RTA/CN 0205-24 TE D - 4 0 - 4 3 3 2 C2 4 0 0 2 1 2 3 LU A 2 4 - 0 0 0 2 3 3 PR 2 1 - 0 0 0 0 9 5 DEVELOPMENT ENGINEERING msippo 11/25/2025 R-4332256 1 BT120-GZT001 0 GENERAL COVER SHEET 2 BT120-GZI001 0 GENERAL INDEX OF DRAWINGS 3 BT120-GZI002 0 GENERAL INDEX OF DRAWINGS 4 BT120-GZI003 0 GENERAL INDEX OF DRAWINGS 5 BT120-GZI004 0 GENERAL INDEX OF DRAWINGS 6 BT120-GZI005 0 GENERAL INDEX OF DRAWINGS 7 BT120-GZI006 0 GENERAL INDEX OF DRAWINGS 8 BT120-GZI701 0 GENERAL INDEX OF DRAWINGS SR 167 9 BT120-GZK000 0 GENERAL PROJECT LOCATION ID PLAN 10 BT120-GZK001 0 GENERAL KEY PLAN 11 BT120-GZN001 0 GENERAL ABBREVIATIONS 12 BT120-GZN002 0 GENERAL ABBREVIATIONS 13 BT120-GZN003 0 GENERAL ABBREVIATIONS 14 BT120-GZN004 0 GENERAL ABBREVIATIONS 15 BT120-GZN005 0 GENERAL ABBREVIATIONS 16 BT120-GZN006 0 GENERAL SYMBOLS AND LEGEND 17 BT120-GZN007 0 GENERAL SYMBOLS AND LEGEND RIGHT OF WAY MONUMENT PLAN 651 BT120-RMP701 0 RIGHT OF WAY MONUMENT PLAN 652 BT120-RPP701 0 RIGHT OF WAY PROPOSED PLAN CIVIL ALIGNMENT PLAN SR 167 STA. 997+00.00 TO STA. 1002+50.00 RIGHT OF WAY PROPOSED PLAN 653 BT120-CAP701 0 CIVIL ALIGNMENT PLAN SR 167 STA. 997+00.00 TO STA. 1002+50.00 654 BT120-CAP702 0 CIVIL ALIGNMENT PLAN SR 167 STA. 1002+50.00 TO STA. 1008+00.00 655 BT120-CAP703 0 CIVIL ALIGNMENT PLAN SR 167 STA. 1008+00.00 TO STA. 202+00.00 CIVIL CIVIL HAUL PLAN SR167CIVIL ALIGNMENT PLAN SR 167 STA. 1008+00.00 TO STA. 202+00.00 656 BT120-CHP701 0 CIVIL CIVIL HAUL PLAN SR167 CIVIL TYPICAL SECTIONS SR167CIVIL CIVIL HAUL PLAN SR167 657 BT120-CRY701 0 CIVIL TYPICAL SECTIONS SR167 658 BT120-CRY702 0 CIVIL TYPICAL SECTIONS SR167 CIVIL SITE PREPARATION PLAN SR 167 STA. 1002+50.00 TO STA. 1008+00.00CIVIL TYPICAL SECTIONS SR167 659 BT120-CSP702 0 CIVIL SITE PREPARATION PLAN SR 167 STA. 1002+50.00 TO STA. 1008+00.00 660 BT120-CSP703 0 CIVIL SITE PREPARATION PLAN SR 167 STA.1008+00.00 TO STA. 202+00.00 CIVIL EROSION AND SEDIMENT CONTROL PLAN SR167 STA. 1002+50.00 TO STA. 1008+00.00CIVIL SITE PREPARATION PLAN SR 167 STA.1008+00.00 TO STA. 202+00.00 661 BT120-CTP702 0 CIVIL EROSION AND SEDIMENT CONTROL PLAN SR167 STA. 1002+50.00 TO STA. 1008+00.00 662 BT120-CTD701 0 CIVIL TESC DETAILS 663 BT120-CTD702 0 CIVIL TESC DETAILS 664 BT120-CTD703 0 CIVIL TESC DETAILS CIVIL PAVING PLAN SR 167 STA. 1002+50.00 TO STA. 1008+00.00CIVIL TESC DETAILS 665 BT120-CPP702 0 CIVIL PAVING PLAN SR 167 STA. 1002+50.00 TO STA. 1008+00.00 666 BT120-CPP703 0 CIVIL PAVING PLAN SR 167 STA. 1008+00.00 TO STA. 202+00.00 CIVIL PAVEMENT MARKING PLAN SR 167 STA. 1002+50.00 TO STA. 1008+00.00 CIVIL PAVEMENT MARKING DETAILS 670 BT120-CLN701 0 CIVIL ILLUMINATION NOTES SR167 671 BT120-CLP701 0 CIVIL ILLUMINATION PLAN SR167 TRAFFIC SIGNAGE PLAN SR 167 STA. 997+00.00 TOP STA. 1002+50.00 CIVIL ILLUMINATION PLAN SR167 672 BT120-TNP701 0 TRAFFIC SIGNAGE PLAN SR 167 STA. 997+00.00 TOP STA. 1002+50.00 673 BT120-TNP702 0 TRAFFIC SIGNAGE PLAN SR 167 STA. 1002+50.00 TO STA. 1008+00.00 674 BT120-TND701 0 TRAFFIC SIGNAGE DETAILS SR 167 IN RENTON TRAFFIC MOTT NOTES SR167TRAFFIC SIGNAGE DETAILS SR 167 IN RENTON 675 BT120-TMN701 0 TRAFFIC MOTT NOTES SR167 676 BT120-TMP701 0 TRAFFIC MOTT PLAN SR167 677 BT120-TMP702 0 TRAFFIC MOTT PLAN SR167 678 BT120-TMP703 0 TRAFFIC MOTT PLAN SR167 679 BT120-TMP704 0 TRAFFIC MOTT PLAN SR167 680 BT120-TMP705 0 TRAFFIC MOTT PLAN SR167 681 BT120-TMP706 0 TRAFFIC MOTT PLAN SR167 682 BT120-TDP701 0 TRAFFIC DETOUR PLAN SR167 CIVIL PAVING PLAN SR 167 STA. 1008+00.00 TO STA. 202+00.00 667 BT120-CMP702 0 CIVIL PAVEMENT MARKING PLAN SR 167 STA. 1002+50.00 TO STA. 1008+00.00 668 BT120-CMP703 0 CIVIL PAVEMENT MARKING PLAN SR 167 STA. 1008+00.00 TO STA. 202+00.00 669 BT120-CMD701 0 CIVIL PAVEMENT MARKING DETAILS CIVIL ILLUMINATION NOTES SR167 GENERAL RIGHT-OF-WAY SHT. No. DWG. No.TITLEREV SHT. No. DWG. No.TITLEREV SOUTH RENTON TRANSIT CENTER / SR 167 ROADWAY IMPROVEMENTS - BOOK 3 OF 3 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL INDEX OF DRAWINGS BT120-GZI701 BT120 E. GOLLER E. GOLLER L. GILBERT J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 12 / 0 5 / 2 4 | 1 2 : 4 6 P M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z I 7 0 1 . D W G S1-BT120-GZI701 FACILITY ID: Xrefs: xBRT-CUD05-TB22x34 GB-SEAL-JKH53550 xS1-BT120-GZI701 xS1-BT120-GZI001-005 ROADWAY CIVIL ALIGNMENT CONSTRUCTION STAGING TYPICAL SECTIONS SITE PAVEMENT MARKING ILLUMINATION EROISION AND SEDIMENT CONTROL TRAFFIC SIGNAGE MAINTENANCE OF TRAFFIC 12/06/2024 0008 RTA/CN 0205-24 MountlakeTerrace Transit Center (L300) Downtown Redmond SE Redmond East Main (E335) E16 Midtown Everett SW Everett Industrial Center SR 526 & Evergreen Mariner Ash Way Northgate (N160) Roosevelt (N150)Redmond Technology Center (E360) (Overlake Transit Center) Overlake Village (E360) South KirklandUniversity of Washington (U250) Capitol Hill (U240) Bellevue Downtown (E335) (Bellevue Transit Center) B e l - R e d & 130th (E340) Spring District & 120th (E335)Wilburton (E335) (Hospital) Redmond South Bellevue(E320) Eastgate Richards Rd. IssaquahDelri d g e Mercer Island(E130) "Current" Sodo (C700) (Lander Street) Judkins Park (E130) (Rainier) West Alderwood Mount Baker (C710) (McClellan Street) Lynnwood Transit Center (L300) Columbia City (C735) (Edmonds/Columbia City) N11 Seattle Ballard Interbay Smith Cove Seattle Center South Lake Union Denny Westlake (C510) University St. (C510) Pioneer Square (C510) International District (C510) Av a l o n AlaskaJunction E09 Othello (C735) C23C19 Be a c o n H i l l ( C 7 1 0 ) C07 Issaquah C05 N03 B07 C04 B09 B11 N09 E01 N13 N15 220th Street (Provisional) N19 Mercer Island Lid (WSDOT) Q03 N21 N23 N25 N27 N29 N33 N35 N37 E19 E21 Q01 K01 W07 W05 Yard O&M Facility MOW Facility Link Control Center N36 Lynnwood N30 N28 N26 N24 N22 N20 N18 N16 N14 N12 N10 Bellevue N08 N06 N04 E30 E28 E26 E24E 2 2 E20 E10 E12 E08 C08 C02 C24 C06 C14 C12 I00 C26 C28 C2 0 C1 8 C2 2 N3 4 B16 B14 B12 B10 B08 B06 C1 6 West Seattle Ballard Y01 M01 M02 M03 E03E02E00 E04 E05 E06 Yard O&M Facility Y02 M04 M05 MOW Facility K00 Q02 W0 6 W04 N17 E27 E25 E11 Mount Baker Lid (WSDOT) "New" Sodo B03 W00 B02 B04 B15 B13 B17 E15 N31 N32 SR 99 & Airport Rd (Provisional) S Graham St. C40 Parking (L200) W03 Parking(L200) Parking (L200) Parking (Provisional) Parking (L200) Parking (L300) Parking (E320) Parking (E360)N07 U District (U140) (Brooklyn) C25 C125 C27 E31 E42 B00 N05 N00 N02 Pine St. Ventilation Facility C01Convention Place Facility E23 E18 E29 E14 C15W01 B01C09 B05C03 NP23 NP21 NP17 NP15 NP13 NP11 EP09 EP27 Q07 Q04 Q05Lakemont (Provisional) Q06 Stadium (C700) (Royal Brougham) Shoreline South (L200) (145th St.) Shoreline North (L200) (185th St.) NE 130th St. (L200) (Provisional) C13 W02 BT310 BT312 BT314 15 t h A v e . N E ( S 3 ) 30 t h A v e . N E ( S 3 ) BT320 BT322 BT324 BT330 BT332 BT334 BT340 BT342 BT344 BT346 BT260 BT350 N E 1 5 3 r d S t . ( S 3 ) N E 1 6 5 t h S t . ( S 3 ) 61 s t A v e . N E ( S 3 ) Lake Forest Park Town Center (S3) 68 t h A v e . N E ( S 3 ) Ke n m o r e Pa r k - n - R i d e ( S 3 ) 10 4 t h A v e . N E ( S 3 ) 98th Ave. NE (S3) Canyon Park (S2) BTP324 BTP340 BTP334 Beardslee Blvd. NE 195th St. (S2) UW Bothell/Cascadia College (S3) BT350 BT240 BT230 BT220 SR 522/I-405TRANSIT HUB (S2) BRICKYARD (S2) KINGSGATE / TOTEM LAKE (S2) BT210NE 85TH (S3) BTP101 BT100 BTP110 BT110 NE 44TH STREET (S1) NP37 NP29 NP27 New Westlake E07 EP29 BTM01 BTM02 BTM03 BTM04 Admin & Ops Parking & Service Guard Booth MOW Hilltop District (T100) Fi f e Ta c o m a D o m e Po r t l a n d A v e Union (C910) Tukwilla/ Intl Blvd. (C755) (S 154th Street) Convention Center (C910) "New" Theater District (C910) "Current" Theater District (C910) T01 T05 T07 T09 T11 T13 T17 T19 T21 T23 T25T27T29T31T33T35T37 Old City Hall (T100) S 4th Ave (T100) Tacoma General (T100) 6th Ave (T100) St J o s e p h ( T 1 0 0 ) Hil l T o p S S p r a g u e A v e S Un i o n A v e S S t e v e n s S t S P e a r l S t Tac o m a Com m u n i t y Co l l e g e T15 Stadium District (T100) S13 S11 S09 South Federal Way S07Federal Way Transit Center (F200) S05S 272nd Street (F200) (Star Lake) S03Kent/ Des Moines (F200) S01Angle Lake (S440) (S 200th Street) C37Airport Exit Loop (C430R)SeaTac Airport (C420) Tacoma C35 Rainier Beach (C735) (Henderson Street) C34 Y00 M00 Ya r d ( C 9 2 0 ) O& M ( C 9 2 0 ) C30 C32 C36 S00 S04 S02 S06 S08 S10 S12S14 T04 T06 T08 T10 T12 T14 T16 T18 T20 T22 T24 T36 T34 T32 T30 T28 T26 SeaTac S 133rd St. (C755) Boeing Access Road Parking Parking (S445) C29 C31 Federal Way Parking (F200) Parking (F200) CP31 C33 SP01 SP03 SP05 SP07 S15 Parking (F200) T03 T0 2 S 2 5 t h BTP120 BT120 SOUTH RENTON (S1) BT130 TUKWILA INTL BLVD (S1) BT140 BURIEN TRANSIT CENTER (S1) Yard O&M Facility MOW Facility LSW Storage Y03 M08 M09 M10 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL PROJECT LOCATION ID PLAN BT120-GZK000 BT120 E. GOLLER C. SAXE M. FOLWELL J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS N X##X## X## X## X## XX## LEGEND: At-Grade Station Grade Separated Station Tunnel Station Facility At-Grade Track Grade Separated Track Tunnel Track Linked Stations Tunnel Station SEE VIEW AT LEFT SEE VIEW AT RIGHT No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 11 / 1 8 / 2 4 | 1 0 : 2 6 A M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z K 0 0 0 . D W G S1-BT120-GZK000 FACILITY ID: Xrefs: xBRT-CUD05-TB22x34 GB-SEAL-JKH53550 12/04/2024 0009 RTA/CN 0205-24 SW GRADY W A Y SW 7TH ST / / / / / / / / / / / / / / / / / / //// / / / / / / / / ///////// // / / / / / / RAI N I E R AVE S HA R D I E AV E S W SR - 1 6 7 SW GRADY W A Y SW 7TH ST / / / / / / / / / / / / / / / / / / //// / / / / / / / / ///////// // / / / / / / RAI N I E R AVE S HA R D I E AV E S W SR - 1 6 7 S W G R A D Y W A Y SW 7 T H S T / / / / ////////////////////// //////////////////////// / / / / / / / / / / / / // /////// /// / / / / / / / / / / /// / / / / / ///////////////// / ////// /// / / / / / HARDIE AVE SWSR-167 I- 4 0 5 N SCALE IN FEET 0150 300300 600 (1" = 300') STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL KEY PLAN BT120-GZK001 BT120 E. GOLLER C. SAXE M. FOLWELL J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID 1"=300' No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 11 / 1 8 / 2 4 | 2 : 1 8 P M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z K 0 0 1 . D W G S1-BT120-GZK001 FACILITY ID: Xrefs: xS1-BT120-VRX001 xBRT-CUD05-TB22x34 xS1-BT120-GZK020 GB-SEAL-JKH53550 xS1-BT120-GZK701 LAKE AVE S CAP - ALIGNMENT CDP - DRAINAGE CMP - PAVEMENT MARKING CPP - PAVING CSP - SITE PREPARATION CLP - ILLUMINATION JCP - SITE COMMUNICATION LHP - HARDSCAPE LPP - PLANTING LRP - IRRIGATION RPP - PROPOSED RIGHT OF WAY TIP - INTELLIGENT TRAFFIC SYSTEM (ITS) UCP - UTILITY DEMO PLAN UWP - WATER UTILITY USP - SEWER UTILITY CROSS REFERENCING OF DRAWINGS BASE SHEET TITLE 1"=20' DRAWING SETS S1-BT120-**P101 S1-BT120-**P102 S1-BT120-**P103 S1-BT120-**P104 S1-BT120-**P105 S1-BT120-**P106 S1-BT120-**P107 01 **P = DESIGN ELEMENT PLAN VIEW DESIGNATION 01 SCALE: 1" = 300' KEY MAP - ROADWAY SHEETS 02 03 04 05 06 02 03 04 05 06 CAP - ALIGNMENT CDP - DRAINAGE CMP - PAVEMENT MARKING CPP - PAVING CSP - SITE PREPARATION CLP - ILLUMINATION JCP - ELECTRICAL AND COMMUNICATION LHP - HARDSCAPE LPP - PLANTING LRP - IRRIGATION RPP - PROPOSED RIGHT OF WAY TIP - INTELLIGENT TRAFFIC SYSTEM (ITS) UCP - COMPOSITE UTILITY UWP - WATER UTILITY USP - SEWER UTILITY CROSS REFERENCING OF DRAWINGS BASE SHEET TITLE 1"=20' DRAWING SETS S1-BT120-**P201 S1-BT120-**P202 S1-BT120-**P203 S1-BT120-**P204 S1-BT120-**P205 01 **P = DESIGN ELEMENT PLAN VIEW DESIGNATION 01 SCALE: 1" = 300' KEY MAP - SITE SHEETS 02 03 04 05 02 03 04 05 SOUTH RENTON TRANSIT CENTER STATION SOUTH RENTON TRANSIT CENTER STATION SCALE: 1" = 300' KEY MAP - SR-167 SHEETS N 07 CROSS REFERENCING OF DRAWINGS BASE SHEET TITLE 1"=20' DRAWING SETS S1-BT120-**P701 S1-BT120-**P702 S1-BT120-**703 01 02 03 CAP - ALIGNMENT CMP - PAVEMENT MARKING CPP - PAVING CTP - TESC CXP - DEMOLITION CLP - ILLUMINATION RMP - RIGHT OF WAY MONUMENTS RPP - PROPOSED RIGHT OF WAY TDP - TRAFFIC DETOUR TMP - TRAFFIC CONTROL TNP - SIGNING **P = DESIGN ELEMENT PLAN VIEW DESIGNATION 07 01 02 03 N N 10404 0010 RTA/CN 0205-24 #NUMBER, TYPE %PERCENT &AND *DIM REQ VERIFICATION BY OTHER DIM /OF @ AT +/-PLUS OR MINUS, DIM REQ FIELD VERIFY Δ TOTAL CENTRAL ANGLE OF SPIRAL AND CIRCULAR CURVES Δc CENTRAL ANGLE OF CIRCULAR CURVE EXTENDING FROM SC TO CS Δc1 SUFFIX (1) DENOTES DATA FOR THE FIRST CIRCULAR CURVE OF A COMPOUND CURVE Δc2 SUFFIX (2) SAME AS ABOVE - SECOND CIRCULAR CURVE OF A COMPOUND CURVE ϴs1 CENTRAL ANGLE OF SPIRAL SUFFIX (1) ϴs2 CENTRAL ANGLE OF SPIRAL SUFFIX (2) ϴs3 CENTRAL ANGLE OF SPIRAL SUFFIX (3) └SINGLE ANGLE ┘└ DOUBLE ANGLE Ø DIAMETER, PHASE (E)EXISTING (F)FUTURE (N)NEW A A AMPERE A/B AIR BRAKE A/C ASPHALTIC CONCRETE A/G AT-GRADE A/R AS REQUIRED A/S ACRYLIC-LATEX SEALANT A/T AUTO TENSION A/V AUDIO VISUAL AASHTO AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS AB ANCHOR BOLT ABD ABANDON(ED) ABDV AUTOMATIC BALL DRIP VALVE ABUT ABUTMENT ABV ABOVE AC ALTERNATING CURRENT, ABOVE COUNTER, AIR COMPRESSOR, ASBESTOS CEMENT, AIR CONDITIONING ACCP AIR CONDITIONING CONTROL PANEL ACD ASBESTOS CEMENT DUCT (CONDUIT) ACI AMERICAN CONCRETE INSTITUTE ACOUS ACOUSTICAL ACOUS PNL ACOUSTICAL PANEL ACP ASBESTOS CEMENT PIPE, ASPHALT CONCRETE PAVEMENT ACPL AUXILIARY CONTROL PANEL ACR ACRYLIC, ACCESS CARD READER ACS ACCESS ACSR ALUMINUM CONDUCTOR STEEL REINFORCED ACT ACOUSTICAL CEILING TILE ACT-# ACOUSTICAL CEILING TILE - TYPE ACU AIR CONDITIONING UNIT AD ACCESS DOOR, AREA DRAIN ADA AMERICAN WITH DISABILITIES ACT ADD ADDENDUM, ADDENDA ADDL ADDITIONAL ADJ ADJACENT, ADJUST(ABLE) AESS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL AF AMP FUSE, AMP FRAME AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AGG AGGREGATE AGG B AGGREGATE BASE AGG SB AGGREGATE SUB BASE AGHA ALTERATION OF GEOLOGICAL HAZARD AREA AHCP AIR HANDLING CONTROL PANEL AHCW AUTOMATIC HIGHWAY CROSSING WARNING AHD AHEAD AHJ AUTHORITIES HAVING JURISDICTION AHU AIR HANDLING UNIT AIC AMPERE INTERRUPTING CURRENT AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AL ALUMINUM ALIGN ALIGNMENT ALM ALARM ALT ALTERNATE ALUM ALUMINUM AMP AMPERE, AMPERAGE ANC ANCHOR(AGE) ANOD ANODIZE(D) ANS AMBIENT NOISE SENSOR ANSI AMERICAN NATIONAL STANDARDS INSTITUTE ANT ANTENNA AP ANGLE POINT, APPROACH APC-# ACOUSTICAL PANEL CEILING AP-# ACOUSTICAL PLASTER TYPE APPROX APPROXIMATELY APT AUXILIARY POWER TRANSFORMER AR ANCHOR ROD ARC ABRASION RESISTANT COATINGS ARCH ARCHITECT, ARCHITECTURAL AREMA AMERICAN RAILWAY ENGINEERING AND MAINTENANCE-OF-WAY ASSOCIATION ARV AIR RELIEF VALVE AS AIR SEPARATOR, AMPMETER SWITCH ASA AMERICAN STANDARDS ASSOCIATION ASL AIRSPACE LEASE ASPH ASPHALT ASSY ASSEMBLY ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS AT AMP TRIP ATB ASPHALT TREATED BASE ATCH ATTACH ATM ALONG TRACK MOVEMENT ATP AUTOMATIC TRAIN PROTECTION ATR ABOVE TOP RAIL ATS AUTOMATIC TRANSFER SWITCH AUTO AUTOMATIC AUX AUXILIARY AV ALARM VALVE, AUDIO VISUAL AVE AVENUE AWG AMERICAN WIRE GAUGE AWI ARCHITECTURAL WOODWORK INSTITUTE AWS AMERICAN WELDING SOCIETY AWWA AMERICAN WATER WORKS ASSOCIATION B B BRICK B&B BALLED AND BURLAPPED B-SPAN BODY SPAN B/BOTTOM/BACK OF B/B BACK TO BACK B/C BOTTOM OF CURB B/L BASE LINE B/W BALANCE WEIGHT, BACK OF WALK BAL BALANCE BAT BATTERY BCD-# BIRD CONTROL SYSTEM TYPE BCP BRANCH CIRCUIT PANEL BCR BIKE CARD READER BD BOARD, BYPASS DAMPER BDA BI-DIRECTIONAL AMPLIFIER BDD BACK DRAFT DAMPER BEG BEGINNING BF BACK FACE, BOTTOM FACE, BACKFILL BFA BY-PASS FEEDER ANCHOR BFF BELOW FINISHED FLOOR BFP BACKFLOW PREVENTER BH BORED HOLE BHP BRAKE HORSE POWER BIA BRICK INSTITUTE OF AMERICA BIJ BONDED INSULATED JOINT BIL BASIC IMPULSE LEVEL BIT BITUMINOUS BJF BITUMINOUS JOINT FILLER BK BACK BKF BACKFILL BKR BREAKER BL BASE LINE, BUILDING LINE, BOUNDARY LINE BLD BUILDING BLK BLOCK BLKG BLOCKING BLKR BICYCLE LOCKER BLST BALLAST BLVD BOULEVARD BM BEAM, BENCHMARK BMP BEST MANAGEMENT PRACTICE(S) BMS BUILDING MANAGEMENT SYSTEM BNSF BNSF RAILWAY BO BOTTOM OF, BREAK OUT, BLOCK OUT, BLOW OFF VALVE BOB BOTTOM OF BRICK BOC BACK OF CURB BOD BOTTOM OF DUCT BOF BOTTOM OF FOOTING BOH BACK OF HOUSE BOP BOTTOM OF PIPE BOS BOTTOM OF STRUCTURE BOT BOTTOM BOW BACK OF WALK BP BACKFLOW PREVENTER BPP BRANCH POWER PANEL BR BRIDGE, BARE ROOT BRD BAROMETRIC RELIEF DAMPER BRG BEARING BRG PL BEARING PLATE BRK-# BRICK MASONRY TYPE BRKT BRACKET BS BOTH SIDES, BIRD SCREEN BSMT BASEMENT BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNITS PER HOUR BV BALL VALVE BVL BEVELED BW BOTH WAYS, BOTTOM OF WALL BZ BRONZE C C CONDUIT, CELSIUS/CENTIGRADE, COMMUNICATIONS, CHANNEL, CLOSE C&C CUT AND COVER C&G CURB AND GUTTER C&S COMMUNICATION AND SIGNALS C/B COVE BASE C/C CENTER TO CENTER, CONCRETE CULVERT C/G CORNER GUARD C/L CURB LINE C/S COUNTERSUNK C-SPAN CROSS SPAN CAB CABINET CAL CALIPER CALC CALCULATED CANT CANTILEVER CAT CATEGORY, CATENARY CATV CABLE TELEVISION CB CATCH BASIN CBB CEMENTITIOUS BACKERBOARD CBL CABLE CC COOLING COIL, CENTER OF CIRCULAR CURVATURE, CIP INTEGRAL COLOR CC-# CCL CENTRAL CONTROL CCTB CORROSION CONTROL TEST BOX CCTV CLOSED-CIRCUIT TELEVISION CCW COUNTER CLOCKWISE CD COLD DRAWN, CONDENSATE DRAIN, CLEARANCE DISTANCE CDC COMMUNICATIONS DISTRIBUTION CABINET CDF CONTROLLED DENSITY FILL CE CONSTRUCTION EASEMENT, CLEARANCE ENVELOPE CED CONCRETE ENCASED DUCTBANK CEM CEMENT CEM BD CEMENT BOARD CEM PLAS CEMENT PLASTER CER CERAMIC CF-# CEMENTITIOUS FIREPROOFING TYPE CF CUBIC FOOT/FEET CFF CAP FOR FUTURE CFLG COUNTERFLASHING CFM CUBIC FEET PER MINUTE CG CENTER OF GRAVITY, CONCRETE GUTTER CG-# CORNER GUARD TYPE CHAM CHAMFER CHD CHORD CHGR CHARGER CHK CHECK CHWS CHILLED WATER SUPPLY CI CAST IRON CIP CAST-IN-PLACE, CAST IRON PIPE CIP-# CAST-IN-PLACE TYPE CIP-S# CONCRETE SEALER TYPE CIRC CIRCULAR CIT CIRCUIT CIV CIVIL CIW CAST IRON WATER CJ CONTROL/CONTRACTION/CONSTRUCTION JOINT CJP COMPLETE JOINT PENETRATION CK CREEK CKT CIRCUIT CL CENTERLINE, CLASS CLF, CLEF CHAIN LINK FENCE CLG CEILING CLG-# CEILING TYPE CLGH CEILING HANGAR CLGS CEILING SUPPORT CLO CLOSET CLP CONCRETE LIGHT POLE, CLAY PIPE CLR CLEAR(ANCE) CLSM CONTROLLED LOW-STRENGTH MATERIAL CM CONSTRUCTION MANAGEMENT CMH COMMUNICATIONS MANHOLE CMP CORRUGATED METAL PIPE CMT CEMENT TREATED BASE CMU-# CONCRETE MASONRY UNIT TYPE CND CONDUIT CNTR CENTER CNR BD CORNER BEAD CO CLEAN OUT, CARBON MONOXIDE CO2 CARBON DIOXIDE COB CITY OF BOTHELL COL COLUMN COMB COMBINATION COMI CITY OF MERCER ISLAND COMM COMMUNICATIONS COMPO COMPOSITION COMPT COMPARTMENT CON CONSOLE CONC CONCRETE CONC-S# CONCRETE SEALANT TYPE COND CONDUIT, CONDENSATE, CONDUCTOR CONN CONNECT(ION) CONST CONSTRUCT(ION) CONT CONTINUOUS/CONTINUATION, CONTAINER GROWN CONT'D CONTINUED STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL GENERAL ABBREVIATIONS BT120-GZN001 BT120 E. GOLLER C. SAXE M. FOLWELL J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS ABBREVIATIONS No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 11 / 1 8 / 2 4 | 1 0 : 2 6 A M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z N 0 0 1 - 0 0 5 . D W G S1-BT120-GZN001-005 FACILITY ID: 12/04/2024 0011 RTA/CN 0205-24 F F FLAG POLE, FAHRENHEIT, FIX F'c 28 DAY CONCRETE STRENGTH F/R FIRE RATED F/T FIXED TERMINATION F TO F FACE TO FACE FA FIRE ALARM, FIXED ANCHOR, FLOOR ASSEMBLY FAAP FIRE ALARM ANNUNCIATOR PANEL FABX FIRE ALARM BOX FAC FACILITY FACP FIRE ALARM CONTROL PANEL FAF FRESH AIR FAN FAI FRESH AIR INTAKE FB FLAT BAR, FORESTED BUFFER FBO FURNISHED BY OWNER FBRGLC FIBERGLASS CONDUIT FC FACE OF CURB, FLEXIBLE CONNECTION, FARE COLLECTION FC-# FLUOROPOLYMER COATING TYPE FCC FIRE COMMAND CENTER FCO FLOOR CLEANOUT FCS FIELD CONTROL SYSTEM FCU FAN COIL UNIT FD FIBER DUCT, FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FDCP FIRE DAMPER CONTROL PANEL FDN FOUNDATION FDP FIBER DISTRIBUTION PANEL FDR FEEDER FE-# FIRE EXTINGUISHER TYPE FEC-# FIRE EXTINGUISHER CABINET TYPE FF FINISHED FLOOR, FAR FACE FFJ FULL FEEDING JUMPER FG FINISH GRADE FH FIRE HYDRANT FHC FIRE HOSE CABINET CONTR CONTRACTOR CONTV CONTROL VALVE COR CITY OF REDMOND COORD COORDINATE CORP CORPORATION CORR CORRIDOR, CORRUGATED COV COVER(ED) CP CONCRETE PIPE, CONDUIT CPLG COUPLING CPP COMMUNICATIONS POWER PANEL CPT CONTROL POWER TRANSFORMER, CONTROL POINT CPW-# CEMENTITIOUS WALL PANEL - TYPE CR CURB RAMP, CONDUIT RISER CRL CANE RAIL CRS COLD ROLLED STEEL CS COMBINED SEWER, CURVE TO SPIRAL CSBC CRUSHED SURFACING BASE COURSE CSJ CONSTRUCTION JOINT, CLOSURE STRIP JOINT CSK CASEWORK CSL CROSSHOLE SONIC LOGGING CSM COMBINED SEWER MANHOLE CSMH COMBINED SEWER MANHOLE CSMT CASEMENT CSP CONCRETE SEWER PIPE CST CAST STONE CSTC CRUSHED SURFACING TOP COURSE CT CERAMIC TILE, CONICAL TEE, CURRENT TRANSFORMER CTB CEMENT TREATED BASE CTR CENTER(S) CTRL CONTROL CTRLR CONTROLLER CTY CABLE TRAY CU COPPER, CUBIC, CONDENSING UNIT CU YD CUBIC YARD CULV CULVERT CV CONTROL VALVE, CONSTANT VOLUME, CABLE VAULT CVLV CHECK VALVE CW CONCRETE WALK, CONTACT WIRE, CLOCKWISE, COLD WATER CWA COUNTERWEIGHT ANCHOR CWP CEMENTITIOUS WALL PANEL CWR CONTINUOUS WELDED RAIL CWT COUNTERWEIGHT CW-# CURTAIN WALL TYPE CY CUBIC YARD(S) D D DEEP, DEPTH, DUCT D/W DRIVEWAY DA DISABLED DB DRY BULB, DIRECT BURIED, DC BREAKER DB DUCT, CONDUIT, DEPTH, DUCTBANK DBA DEFORMED BAR ANCHOR DBH DIAMETER BREAST HEIGHT DBL DOUBLE Dc DEGREE OF CIRCULAR CURVE (ARC DEFINITION) DC DIRECT CURRENT, DISTRIBUTION CABINET DCDA DOUBLE CHECK DETECTOR ASSEMBLY DCM DESIGN CRITERIA MANUAL DCVA DOUBLE CHECK VALVE ASSEMBLY DCW DOMESTIC COLD WATER DDCA DOUBLE DETECTOR CHECK ASSEMBLY DEF DEFLECTION DEF JT DEFLECTION JOINT DEG DEGREE DEL DELETE DEMO DEMOLITION DESC DESCRIPTION DET, DTL, DETAIL(S) DTLS DF DIRECT FIXATION, DRINKING FOUNTAIN DGA DOWN GUY ANCHOR DH DUCT HEATER DHW DOMESTIC HOT WATER DHWC DOMESTIC HOT WATER CIRCULATION DI DROP INLET, DUCTILE IRON, DISCRETE INPUT DIA, DIAM DIAMETER DID DOOR INTRUSION DETECTOR DIFF DIFFUSER DIM DIMENSION DIP DUCTILE IRON PIPE DIR DIRECTION DISC DISCONNECT DISC SW DISCONNECT SWITCH DISCH DISCHARGE DISTR DISTRIBUTION DL DEAD LOAD DLN DRIPLINE DMP-# DECORATIVE METAL PANEL TYPE DN DOWN DO DITTO, DISCRETE OUTPUT DOC DEGREE OF CURVATURE DOE DEPARTMENT OF ECOLOGY DOIT DEPARTMENT OF INFORMATION TECHNOLOGY DOM DOMESTIC DP DAMPPROOFING, DEEP DPR DAMPER DR DRIVE, DOOR DRN DRAIN DS DOWNSPOUT, DOOR SWITCH DSP DRY STANDPIPE DWG(S) DRAWING(S) DWL DOWEL DWR DRAWER DWV DRAIN, WASTE, VENT DX DIRECT EXPANSION E E EAST/EASTING, ELECTRICAL E/P EDGE OF PAVEMENT E/S EDGE OF SHOULDER Ea ACTUAL TRACK SUPERELEVATION (INCHES) EA EACH, EXHAUST AIR EAT ENTERING AIR TEMPERATURE EB EASTBOUND EBC EMBEDDED CONDUIT EC ELECTRICAL CONTRACTOR, END CAP, ELECTRICAL CONDUIT, EPOXY-COATED, ELECTRICALLY COMMUTATED ECS ENVIRONMENTAL CONTROL SYSTEM ED ELECTRIC(AL) DUCT EDD EXHAUST DUCT DAMPER EER ENERGY EFFICIENCY RATING EF EACH FACE, EXHAUST FAN EFAN EXHAUST FAN EFC EXPOSED FINISH CONCRETE EPOXY FIBERGLASS CONDUIT EFD EXHAUST FAN DAMPER EFF EFFICIENCY EFW EFFECTIVE FLUID WEIGHT EG EXISTING GRADE EGR EMERGENCY GUARD RAIL EHC ELECTRIC HEATING COIL EHS EXTRA HIGH STRENGTH EI ELECTRICAL INTERLOCK EJ EXPANSION JOINT EJ-# / EJC-# EXPANSION JOINT COVER TYPE ELAST-# ELASTOMERIC COATING TYPE EL/ELEV ELEVATION, ELEVATOR ELAST ELASTOMERIC ELEC/ELECT ELECTRIC(AL) ELECPBD ELECTRIC PANEL BOARD ELP EMERGENCY LIGHTING PANEL EM ELECTROMAGNETIC MONITORING EMB EMBEDMENT, EMBEDDED PLATE/ITEM EMER EMERGENCY EMH ELECTRIC MANHOLE EMI ELECTROMAGNETIC INTERFERENCE EMP EMERGENCY MANAGEMENT PANEL EMR ELEVATOR MACHINE ROOM EMRF EMERGENCY REVERSIBLE FAN EMS EMERGENCY MANAGEMENT SYSTEM EMT ELECTRICAL METALLIC TUBING ENCL ENCLOSURE ENGR ENGINEER ENTR ENTRANCE EOP/EP EDGE OF PAVEMENT EPF ELEVATOR SHAFT PRESSURIZATION FAN EPO EMERGENCY POWER OFF EPP EMERGENCY POWER PANEL EQ EQUAL EQNBK STATION EQUATION BACK EQNAHD STATION EQUATION AHEAD EQPT EQUIPMENT EQUIV EQUIVALENT ERER EMERGENCY BACKPACK STORAGE ES EACH SIDE, EXTRA STRENGTH ESC ESCALATOR ESL ELECTRIC STREET LIGHT ESMT EASEMENT ESP EXTERNAL STATIC PRESSURE EST ESTIMATED ETC ET CETERA ETEL EMERGENCY TELEPHONE ETS EMERGENCY TRIP STATION ETT ELECTRIC TRANSMISSION TOWER ETW EDGE OF TRAVELED WAY Eu UNBALANCED TRACK SUPERELEVATION (INCHES) EUH ELECTRICAL UNIT HEATER EV ELECTRIC VAULT, ELECTRIC VEHICLES EVP EMERGENCY VEHICLE PREEMPTION EW EACH WAY, EASTBOUND TO WESTBOUND EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EWT ENTERING WATER TEMPERATURE EX/EXIST EXISTING EXC/EXCAV EXCAVATION EXF EXHAUST FAN EXH EXHAUST EXP EXPANSION EXPO EXPOSED EXT EXTERIOR, EXTINGUISHER, EXTERNAL FHMS FLAT HEAD MACHINE SCREW FHV FIRE HOSE VALVE FIN FINISH(ED) FIX FIXED FIXT FIXTURE FJ FEEDER JUMPER FL FLOW LINE, FLANGE FLA FULL LOAD AMPA FL-#FLOURPOLYMER COATING - TYPE FLEX FLEXIBLE FLG FLANGE FLH FLATHEAD FLR FLOOR FLSH FLASHING FLUOR FLUORESCENT FM FORCE MAIN FMP FIRE MANAGEMENT PANEL FN FENCE FND FOUNDATION, FAN DAMPER FNIC FUTURE NOT IN CONTRACT FO FACE OF, FIBER OPTIC FOB FACE OF BRICK FOC FACE OF CONCRETE, FACE OF CURB FOF FACE OF FINISH FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FOIO FURNISHED BY OWNER, INSTALLED BY OWNER FOP FACE OF POLE FOS FACE OF SLAB / STUD / STRUCTURE, FACTOR OF SAFETY FOT FIBER OPTIC TRANSMISSION SYSTEM FOW FACE OF WALL FP FIRE PROTECTION FPAP FALL PROTECTION ANCHOR POST FPM FEET PER MINUTE FPP FIBER OPTIC PATCH PANEL FPRF FIRE PROOF FR FROM FREQ FREQUENCY, FREQUENTLY FRP FIBERGLASS REINFORCED PLASTIC/POLYMER FRT FIRE RESISTANT TREATED FS FAR SIDE, FIRE SERVICE, FUSED SWITCH FSD FIRE SMOKE DAMPER FT FOOT/FEET FTB FLUIDIZED THERMAL BACKFILL FTC FIRE EXTINGUISHER/TELEPHONE CABINET FTG FOOTING FUR FURRING FURN FURNISH FUT FUTURE FVE FARE VENDING EQUIPMENT FVEC FIRE VALVE & EXTINGUISHER CABINET FVNR FULL VOLTAGE NON-REVERSING FW FIELD WELD FWD FORWARD FXTR FIXTURE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL GENERAL ABBREVIATIONS BT120-GZN002 BT120 E. GOLLER C. SAXE M. FOLWELL J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS ABBREVIATIONS (CONT'D) No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 11 / 1 8 / 2 4 | 1 0 : 2 6 A M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z N 0 0 1 - 0 0 5 . D W G S1-BT120-GZN001-005 FACILITY ID: 12/04/2024 0012 RTA/CN 0205-24 I J M K I/O INPUT/OUTPUT I/R IN-RUNNING (RIDING CONTACT WIRE) I INTERLOCK IA INTRUSION ALARM IB IMPEDANCE BONDS IBC INTERNATIONAL BUILDING CODE ICC INTERNATIONAL CODE COUNCIL ID INSIDE DIAMETER/DIMENSION IDENTIFICATION IE INVERT ELEVATION IF INSIDE FACE IJ INSULATING / ISOLATION JOINT ILLUM ILLUMINATED IM INFORMATION MONITOR IN INCH(ES) IN WC INCHES WATER COLUMN INC INCLUDE, INCOMING INCD INCANDESCENT INCL INCLUDE, INCLUDING IND INDICATE J JUMPER JAN JANITOR JB, J-BOX JUNCTION BOX JCT JUNCTION JS JANITOR SINK JST JOIST JT/JNT JOINT JT BKR JOINT BACKER K KIP (1000 POUNDS) KA KILOAMPERE KC KING COUNTY KCMIL THOUSAND CIRCULAR MILS KCWW KING COUNTY WASTE WATER KF KIP-FOOT KO KNOCK-OUT KLF KIPS PER LINEAR FOOT KSF KIPS PER SQUARE FOOT KSI KIPS PER SQUARE INCH KV KILOVOLT KVA KILOVOLT AMPERE KVAR KILOVOLT AMPERES REACTIVE KW KILOWATT KWHR KILOWATT-HOUR M METER, MOVEABLE M/L MAIN LINE M/N MODEL NUMBER M/O MOTOR OPERATED M/W MESSENGER WIRE MA MAST ARM MACH MACHINE MAINT MAINTENANCE MAS MASONRY MAT MIXED AIR TEMPERATURE MATL MATERIAL MAV MANUAL AIR VENT MAX MAXIMUM MBH 1000 BRITISH THERMAL UNITS PER HOUR MBR MEMBER G G1 GRADE SUFFIX (1) G2 GRADE SUFFIX (2) G GAS, GROUND, GRADE G/L GROUND/GRADE LINE G/R PL GUARD RAIL PLATE GA GAUGE GAL GALLON GALV GALVANIZED, HOT DIPPED GALVANIZED GALVS GALVANIZED STEEL GB GRAB BAR, GROUND BUS GB-# GLAZING BLOCK TYPE GC GENERAL CONTRACTOR GD GUIDEWAY DISPERSION, GARAGE DRAIN GDR-# GUARDRAIL SYSTEM TYPE GEN GENERATOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GFI GROUND FAULT INTERRUPTER GFRP GLASS FIBER REINFORCED PLASTIC GFRP-# GLASS FIBER REINFORCED PLASTIC - TYPE GH GROUND HYDRANT GI GROUND INLET GL GLAZING GL-# GLAZING TYPE GM GAS METER GND GROUND GP GAUGE PLATE GP-# GRAFITTI COATING TYPE GPM GALLONS PER MINUTE GR GRADE, GAS REGULATOR GALVANIZED GRAN GRANITE GRD GROUNDING DEVICE, GRILLE REGISTER DIFFUSER GRL GRILLE GRL-# OVERHEAD COILING GRILLE TYPE GRS GALVANIZED RIGID STEEL GRSC GALVANIZED RIGID STEEL CONDUIT GRTG-# GRATING TYPE GRX GRADE CROSSING GS GALVANIZED STEEL GSC GALVANIZED STEEL CONDUIT GSP GALVANIZED STEEL PIPE, CONDUIT (GSC) GUY GUY LINE GV GAS VALVE, GATE VALVE, GREASE VENT GVP GAS VENT PIPE GW GREASE WASTE GWB GYPSUM WALL BOARD GYP GYPSUM H H HIGH, HORIZONTAL, HEIGHT H-SPAN HEAD SPAN H/R HEAD ROOM H/W HOT WATER HAS HEADED ANCHOR STUD HB HOSE BIBB HC HEATING COIL, HOLLOW CORE HD HARD DRAWN HDPE HIGH DENSITY POLYETHYLENE (PIPE) HDR HEADER HDW HARDWARE HEX HEXAGONAL HH HAND HOLE HI TRACK HIGHPOINT HK HOOK HM HOLLOW METAL HMA HOT MIX ASPHALT HMD HOLLOW METAL DOOR HMF HOLLOW METAL FRAME HNDRL-# HAND RAIL TYPE HO HAND OPERATED HOF HEEL OF FROG HORIZ HORIZONTAL HP HORSE POWER, HIGH PRESSURE HPC HIGH PERFORMANCE COATING HPC-# HIGH PERFORMANCE COATING TYPE HPG HIGH PRESSURE GAS HPT HIGH POINT HR HANDRAIL HRC HEAT RECOVERY COIL HRL HIGH RAIL LEVEL HS HIGH STRENGTH, HEEL OF SWITCH HSB HIGH STRENGTH BOLT HSS HOLLOW STEEL/STRUCTURAL SECTION HIGH STRENGTH STEEL HT HEIGHT(H), HAND THROW (MANUAL) HTR HEATER HV HIGH VOLTAGE HVAC HEATING, VENTILATION & AIR CONDITIONING HW HEADWALL HWT HOT WATER TANK HYD HYDRANT HZ HERTZ INFO INFORMATION INSP INSPECTION, INSPECT INST INSTANTANEOUS INSUL-# INSULATION TYPE INT INTERIOR, INTERMEDIATE INV INVERT IP IRON PIPE, INTERMEDIATE PRESSURE IPS IRON PIPE SIZE IR INSIDE RADIUS, IN RUNNING IRG, IRR, IRRIGATION IRRIG ITC INTERFACE TERMINAL CABINET ITS INFORMATION TECHNOLOGY SYSTEM, INTELLIGENT TRANSPORTATION SYSTEMS IW INDIRECT WASTE L L LEFT, LENGTH, LINED, LINING, STRUCTURAL ANGLE, LONGITUDINAL L-L LINE TO LINE VOLTAGE L/T LEFT TRACK LA LIGHTNING ARRESTOR LAD LADDER LAM LAMINATE LAT LATERAL, LEAVING AIR TEMPERATURE LAV LAVATORY LB(S) POUND(S) LB/FT POUNDS PER FOOT LBF POUNDS FORCE Lc TOTAL LENGTH OF CIRCULAR CURVE LC LIGHTING CONTROL LCP LIGHTING CONTROL PANEL LOCAL CONTROL PANEL LED LIGHT EMITTING DIODE LF LINEAR FOOT/FEET LG LENGTH LH LEFT HAND LHR LEFT HAND REVERSE LID LOW IMPACT DRAINAGE ZONE LIN LINEAR LJ LEADED JOINT LJT LONGITUDINAL JOINT LL LIVE LOAD LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LNWD LYNNWOOD LO TRACK LOWPOINT LOC LIMITS OF CONSTRUCTION, LOCATION LONG LONGITUDINAL LOP LIMIT OF PAVEMENT LR-# LEAN RAIL TYPE LP LOW PRESSURE, LIGHTING PANEL LPT LOW POINT LR LOW RAIL LRT LIGHT RAIL TRANSIT LRV LIGHT RAIL VEHICLE Ls TOTAL LENGTH OF SPIRAL Ls1 SUFFIX (1) AT SYMBOL DENOTES DATA FOR FIRST SPIRAL IN UNSYMMETRICAL SPIRALIZED CURVE Ls2 SUFFIX (2) - SAME AS ABOVE, SECOND SPIRAL Ls3 SUFFIX (3) - SAME AS ABOVE, THIRD SPIRAL LS LUMP SUM, LINE SECTION LSL LONG SLOTTED HOLES LT LEFT, LEAK TESTING, LIGHT LTG LIGHTING LV LOW VOLTAGE, LAVATORY LVC LENGTH OF VERTICAL CURVE (PVC TO PVT) LVL LEVEL LVR-# LOUVER TYPE LWT LEAVING WATER TEMPERATURE MC MECHANICAL CONTRACTOR, MISCELLANEOUS CHANNEL, MAGNETIC CONTACT SWITCH MC-# METAL CEILING TYPE MCA MINIMUM CIRCUIT AMPPACITY MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MCD MULTIPLE CONCRETE DUCTS, CONDUITS MD-# STRUCTURAL METAL DECK MD MEASURE DOWN, MOTORIZED DAMPER MDE MAXIMUM DESIGN EARTHQUAKE MDF MEDIUM DENSITY FIBERBOARD MDG MOLDING MDP MAIN DISTRIBUTION PANEL MDPR MOTORIZED DAMPER MECH MECHANICAL MED MEDIUM MEMB MEMBRANE MEP MECHANICAL ELECTRICAL PLUMBING MEZZ MEZZANINE MFR MANUFACTURER MH MAINTENANCE HOLE, MANHOLE MIL EQUAL TO 1/1000TH OF AN INCH (0.001") MIN MINIMUM MISC MISCELLANEOUS MJ MECHANICAL JOINT, MOVEMENT JOINT MLT MOUNTLAKE TERRACE MLO MAIN LUGS ONLY MM MILLIMETER MO MASONRY OPENING MOD MODULAR, MOTOR OPERATED DAMPER, MODULATING, MODIFIED MON MONUMENT MOP MOTOR OPERATED MOT MAINTENANCE OF TRAFFIC MOV MOVABLE MP MILE POST, MEDIUM PRESSURE, MID-POINT, MORE PERMISSIVE SPEED MP-# METAL PANEL TYPE MPA MID-POINT ANCHOR MPB MAIN POWER SWITCHBOARD MPH MILES PER HOUR MR MOISTURE RESISTANT MRP-# METAL ROOF PANEL TYPE MRSS MOTOR RATED SNAP SWITCH MRT MORTAR MS MOTOR STARTER MSB MAIN SWITCHBOARD MSE MECHANICALLY STABILIZED EARTH MSFS METAL STRUT FRAMING SYSTEM MSL MEAN SEA LEVEL MSP MOTOR STARTER PANEL MT MAGNETIC TESTING, MISCELLANEOUS TEE MTB MAIN TERMINAL BOARD MTD MULTIPLE TILE DUCT/CONDUIT, MOUNTED MTG MOUNTING MTL METAL MTR METER MUTCD MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL GENERAL ABBREVIATIONS BT120-GZN003 BT120 E. GOLLER C. SAXE M. FOLWELL J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS ABBREVIATIONS (CONT'D)ABBREVIATIONS (CONT'D) No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 11 / 1 8 / 2 4 | 1 0 : 2 6 A M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z N 0 0 1 - 0 0 5 . D W G S1-BT120-GZN001-005 FACILITY ID: 12/04/2024 0013 RTA/CN 0205-24 mV MILLIVOLT MVA MEGAVOLT AMPERE MVSS MEDIUM VOLTAGE SUBSTATION MW MEGAWATT, MESSENGER WIRE N N NORTH/NORTHING, NEUTRAL N/A NOT APPLICABLE NB NORTHBOUND NBR NON-BRIDGING NC NORMALLY CLOSED NCWD NORTH CITY WATER DISTRICT NE NORTHEAST NEC NATIONAL ELECTRICAL CODE NEG NEGATIVE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NESC NATIONAL ELECTRIC SAFETY CODE NF NEAR FACE NFHB NON-FREEZE HOSE BIB NGPA/NGPE NATIVE GROWTH PROTECTION AREA/EASEMENT NIC NOT IN CONTRACT NL NIGHT LIGHT NMC NON-METALLIC CONDUIT NO NORMALLY OPEN NO./No. NUMBER NOM NOMINAL NPCW NON POTABLE COLD WATER NPDES NATIONAL POLLUTION DISCHARGE ELIMINATION SYSTEM NPS NOMINAL PIPE SIZE NPT NATIONAL PIPE THREAD NR NOT REGISTERED NRCP NON-REINFORCED CONCRETE PIPE NS NEAR SIDE, NOT SUPPORTED NSR NOT SUPPORTED OR REGISTERED NST NOT STEEPER THAN NTS NOT TO SCALE NUM NUMBER NW NORTHWEST, NOISE WALL O O OPEN, OIL O/L OVERLAP O/R OUT-OF-RUNNING (NON-RIDING CONTACT WIRE) O/S OFFSET OA OUTSIDE AIR, OVERALL OBD OPPOSED BLADE DAMPER OC ON CENTER OCS OVERHEAD CATENARY/CONTACT SYSTEM OD OUTSIDE DIAMETER/DIMENSION ODE OPERATIONAL DESIGN EARTHQUAKE OF OIL FILLED, OUTSIDE FACE OFCI OWNER FURNISHED CONTRACTOR INSTALLED OH OVERHEAD, OPPOSITE HAND OHB OVERHEAD BRIDGE OHE OVERHEAD ELECTRICAL OHP OVERHEAD POWER P P PANEL, PIPE, POLE, PAINT, PILASTER OFFSET FROM INITIAL TANGENT TO PC OF THE SHIFTED CIRCLE P/C PRECAST P/S PRE-STRESSED P/T POST TENSIONED, POCKET TRACK PA PUBLIC ADDRESS PADC PUBLIC ADDRESS DISTRIBUTION CABINET (REMOTE AMPLIFIER RACK) PAN PANTOGRAPH PB-# PAVER - WAYFINDING BRAID - TYPE PB PULLBOX, PUSHBUTTON PBX PRIVATE BRANCH EXCHANGE PC POINT OF CURVATURE, POINT OF CHANGE FROM TANGENT TO CIRCULAR CURVE PC CONC PRECAST CONCRETE PC-# PRECAST CONCRETE PAVER - TYPE PCC PORTLAND CEMENT CONCRETE, POINT OF COMPOUND CURVATURE PCCP PORTLAND CEMENT CONCRETE PAVEMENT PCF POUNDS PER CUBIC FOOT PCP PLANTING CONTROL POINT PCP-# PRECAST CONCRETE PANEL - TYPE PD PLASTIC DUCT/CONDUIT, PERFORATED PE PRELIMINARY ENGINEERING, POLYETHYLENE PED PEDESTRIAN PEF PLATFORM EXHAUST FAN PERF PERFORATED PERP PERPENDICULAR PET PUBLIC EMERGENCY TELEPHONE PF POINT OF FROG PG PERFORMANCE GRADE PGL PROPOSED/PROFILE GRADE LINE PGRS PVC COATED GRS PGRSC PVC COATED GRS CONDUIT PH PHASE, POTHOLE PI POINT OF INTERSECTION OF TWO TANGENTS PIS POINT OF INTERSECTION OF TANGENTS OF A SPIRAL PIP PROTECT IN PLACE PITO POINT OF INTERSECTION OF TURNOUT STRAIGHT AND DIVERGING SIDES PIV POST INDICATOR VALVE PJP PARTIAL JOINT PENETRATION PL PLATE, PROPERTY LINE, PLACE, PLASTIC PLAM PLASTIC LAMINATE PLAM-# PLASTIC LAMINATE - TYPE PLAS PLASTER PLAT PLATFORM PLBG PLUMBING PLC PLACE(S) PLF POUNDS PER LINEAL FOOT PLP PLASTIC PIPE PLUMB PLUMBING PLYWD PLYWOOD PM PARKING METER PMJF PRE-MOLDED JOINT FILLER PNL PANEL PNT POINT PNT-# PAINT COLOR PO PUSH-ON JOINT, POWER OPERATED POB POINT OF BEGINNING POC POINT ON CURVE, POINT OF CONNECTION POE POINT OF ENDING, POWER OVER ETHERNET POH POWER OVERHEAD POS POINT OF STATIONING, POSITIVE PP PETROLEUM PRODUCTS, POWER POLE POWER PANEL PPB PEDESTRIAN PUSH BUTTON PR PAIR, PROPOSED PRC POINT OF REVERSE CURVATURE PREFAB PREFABRICATED PREFIN PREFINISHED PRELIM PRELIMINARY PROJ PROJECTION PROP PROPOSED PRV PRESSURE REDUCING VALVE PRVT PRIVATE PS-#PRECAST CONCRETE STAIR, TREAD/LANDING PS POINT OF SWITCH, PRESTRESSING PSE PUGET SOUND ENERGY PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE PT POINT OF TANGENCY, POCKET TRACK, PRESSURE TREATED, POINT OF CHANGE FROM CIRCULAR CURVE TO TANGENT, POST TENSIONING PTZ PAN TILT ZOOM PT-# PORCELAIN TILE - TYPE, SURVEY POINT NUMBER PVC POLYVINYL CHLORIDE (PIPE), POINT OF VERTICAL CURVATURE PVCC POINT OF VERTICAL COMPOUND CURVE PVI POINT OF VERTICAL INTERSECTION PVMT PAVEMENT PVT POINT OF VERTICAL TANGENCY PWR POWER Q QT QUARRY TILE QTY QUANTITY QUAD QUADRANT R R - I/O REMOTE INPUT/OUTPUT R RADIUS, RISER, RANGE RESISTANCE, RIM, RELAY, RIGHT RC RADIUS OF CIRCULAR CURVE RS RADIUS OF SPIRAL R/T RIGHT TRACK RA RETURN AIR, RADIO ANTENNA RAD RADIUS, RADIAL RA-# ROOFING ASSEMBLY TYPE RAL-# ROOF ACCESS LADDER TYPE RAT RETURN AIR TEMPERATURE RB-# RESILIENT BASE - TYPE RB READER BOARD RC REINFORCED CONCRETE RCP REINFORCED CONCRETE PIPE, REFLECTED CEILING PLAN RCPR REINFORCED CONCRETE PIPE RUBBER GASKET RCPT RECEPTACLE RCV REMOTE CONTROL VALVE RCVR RECEIVER RD ROAD, ROOF DRAIN, RADIO DISTRIBUTION RDWY ROADWAY RE RIM ELEVATION, RESIDENT ENGINEER RUNNING EDGE OF RAIL RECON RECONNECT RECT RECTANGULAR, RECTIFIER REF REFERENCE REFRIG REFRIGERANT REG REGISTER REINF REINFORCE(D) (ING) (MENT) RELOC RELOCATE REQD REQUIRED RES RESERVOIR RESP-# EPOXY RESINOUS FLOORING RET RETAINING, RETURN(ED) REV REVISED/REVISION, REVERSE(IBLE) RFG ROOFING RFL-# RESILIENT FLOORING - TYPE RFLD REFLECTED RGS RIGID GALVANIZED STEEL RGSC RIGID GALVANIZED STEEL CONDUIT RH RIGHT HAND RHR RIGHT HAND REVERSE RJ RESTRAINED JOINT RLL RAIN WATER LEADER, REFRIGERANT LIQUID LINE RLUB RAIL LUBRICATOR RM ROOM RMV REMOVE RNLD RONALD WASTEWATER DISTRICT RO ROUGH OPENING ROT ROTATED VIEW ROW, R/W RIGHT-OF-WAY RP RADIUS POINT RPBP REDUCED PRESSURE BACKFLOW PREVENTER RPM REVOLUTIONS PER MINUTE RR RAILROAD RRX RAILROAD GRADE CROSSING RS-A RIPARIAN SHRUB BUFFER 'A' RS-B RIPARIAN SHRUB BUFFER 'B' RSC RIGID STEEL CONDUIT RSCL RAILROAD SIGNAL AND COMMUNICATIONS LINE RSD-# RESINOUS STATIC DISSIPATIVE FLOORING - TYPE RSL REFRIGERANT SUCTION LINE RT-# ROOF SYSTEM TYPE RT RIGHT RTD RESISTANCE TEMPERATURE DETECTOR RTU REMOTE TERMINAL UNIT RVS REVERSE RW RETAINING WALL S S SOUTH, SLOPE, SINK, S-SHAPE S-SPAN STEADY SPAN S-T SELF TAPPING S/C SIGNAL/COMMUNICATION S/DW SINK WITH ATTACHED DISHWASHER S/S SERVICE SINK S/W SIDEWALK SA SUPPLY AIR, SURGE ARRESTOR SAF SUPPLY AIR FAN SAFF SELF-ADHERED FLEXIBLE FLASHING SAFTP STAND-ALONE FARE TRANSACTION PROCESSOR SAN SANITARY SEWER SAP SUBSTATION ALARM PANEL SAT SUPPLY AIR TEMPERATURE, SPRAYED ACOUSTIC TREATMENT SB SOUTHBOUND, STRADDLE BENT SBR SEALANT AND BACKER ROD SC SPIRAL TO CURVE SIGNAL/COMMUNICATION SCADA SUPERVISORY CONTROL AND DATA ACQUISITION SCAT SIMPLE CATENARY AUTO TENSION SCFT SIMPLE CATENARY FIXED TERMINATION SCH/SCHED SCHEDULE SCL SEATTLE CITY LIGHT SCR SMART CARD READER, SCREW SCRN SCREEN SD STORM DRAIN, SMOKE DETECTOR SDD SUPPLY DUCT DAMPER SDMH STORM DRAIN MAINTENANCE HOLE, STORM DRAIN MANHOLE SDT SMOKE DETECTOR SE SOUTHEAST SEC SECOND, SECURITY, SECTION SECT SECTION SEER SEASONAL ENERGY EFFICIENCY RATIO SEG SEGMENT(AL) SEM SEQUENTIAL EXCAVATION METHOD SENS SENSIBLE SEQ SEQUENCE SERV SERVICE SF SQUARE FOOT/FEET, SUPPLY FAN SF-# STORE FRONT SYSTEM TYPE SFD SUPPLY FAN DAMPER OHWM ORDINARY HIGH WATER MARK OP, OPL OIL PIPELINE, OLYMPIC PIPELINE OPNG OPENING OPP OPPOSITE OR OUTSIDE RADIUS ORD OVERFLOW ROOF DRAIN ORL OVERFLOW RAINWATER LEADER OS OCCUPANCY SENSOR OSA OUTSIDE AIR OSD OVERHEAD STORM DRAIN OTC OVERLAKE TRANSIT CENTER OTM OTHER TRACK MATERIAL OTS OPEN TO STRUCTURE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL GENERAL ABBREVIATIONS BT120-GZN004 BT120 E. GOLLER C. SAXE M. FOLWELL J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS ABBREVIATIONS (CONT'D)ABBREVIATIONS (CONT'D) No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 11 / 1 8 / 2 4 | 1 0 : 2 6 A M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z N 0 0 1 - 0 0 5 . D W G S1-BT120-GZN001-005 FACILITY ID: 12/04/2024 0014 RTA/CN 0205-24 U X Y Z W V U/C UNDER CONSTRUCTION U/S UNDERSIDE UBC UNIFORM BUILDING CODE UD UNDERDRAIN UG UNDERGROUND, UNDERGRADE UGB UNDERGRADE BRIDGE UH UNIT HEATER UL UNDERWRITER LABORATORIES UNEX UNEXCAVATED UNK UNKNOWN UNO UNLESS NOTED OTHERWISE UP UTILITY POLE, UNION PACIFIC RR UPS UNINTERRUPTABLE POWER SUPPLY UST UNDERGROUND STORAGE TANK UTIL UTILITY UV ULTRAVIOLET, UTILITY VAULT V VALVE COVER/BOX, DESIGN VELOCITY IN MILES PER HOUR, VERTICAL, VOLT(S) VA VOLT AMPS VAC VACANT VAR VARIABLE/VARIES, VARIETY VAV VARIABLE AIR VOLUME VB VAPOR BARRIER VC VERTICAL CURVE VCD VITRIFIED CLAY DUCT, CONDUIT VCP VITRIFIED CLAY PIPE VCT VINYL COMPOSITION TILE VCZ VEGETATION CLEAR ZONE VD VOLUME DAMPER VE VENT VENT VENTILATE (ION) VERT VERTICAL VIF VERIFY IN FIELD, VERTICAL INSIDE FACE VLT VAULT VMS VARIABLE MESSAGING SYSTEMS/SIGN VP VAPOR PROOF VPF VEGETATION PROTECTION FENCING VPZ VEGETATION PROTECTION ZONE VOIP VOICE OVER IP VS VOLTMETER SWITCH VTR VENT THROUGH ROOF W WEST, WATT, WATER, WIRE, WASTE, WIDE, WIDTH, WIDE FLANGE SHAPE W.M. WILLAMETTE MERIDIAN W/WITH W/I WITHIN W/O WITHOUT WAB-# WATER AND AIR BARRIER TYPE WAT WATER WABO WASHINGTON ASSOCIATION OF BUILDING OFFICIALS WB WESTBOUND, WATER BOX, WET BULB WC WATER CLOSET, WATER COLUMN X BEARING TYPE CONN W/THREADS EXCLUDED FROM SHEAR PLANE XBM CROSSBEAM XFMR TRANSFORMER XMTR TRANSMITTER XS EXTRA STRONG X-ING CROSSING X-OVER CROSSOVER X-SPAN CROSS SPAN Y WYE, YARD, YELLOW YD YARD YL YARD LEADx Z IMPEDANCE SFRM SPRAY-APPLIED FIRE RESISTIVE MATERIAL SH SHOWER/TUB, STANDARD HYDROSEED, SYSTEM HEIGHT SHC SHOTCRETE SHT SHEET SHTHG SHEATHING SI SECTION INSULATOR SIG SIGNAL SIM SIMILAR SJO STANDARD JUNIOR OIL RESISTANT COMPOUND SJT SCORE JOINT SL STREET LIGHT, SHELTER LIGHT, SLOPE, SOUND LINED, SLEEVE SL-#SLOPED GLAZING - TYPE SLJ STREET LIGHT JUNCTION BOX SLNT SEALANT SLSM SOUND LINED SHEET METAL SM SHEET METAL SMFO SINGLE MODE FIBER OPTIC SMR SURFACE METAL RACEWAY SNS STREET NAME SIGN SOE SUPPORT OF EXCAVATION SOG SLAB ON GRADE SOP SET OUT POINT SOV SHUT OFF VALVE SP STEEL PIPE/DUCT/CONDUIT, STATIC PRESSURE, SUMP PUMP SPA, SPC SPACES, SPACING SPEB SOUTH PORTAL ELECTRICAL BUILDING SPEC SPECIFICATION(S) SPF STAIRWELL PRESSURIZATION FAN SPKR SPEAKER SPL SOLDIER PILE & LAGGING SPP SPECIES SPR SPRINKLER SPST SINGLE POLE SINGLE THROW SPU SEATTLE PUBLIC UTILITIES SQ SQUARE SQ FT SQUARE FOOT SQ IN SQUARE INCH SQHD SQUARE HEAD SREG SUPPLY REGISTER SS SANITARY SEWER, STANDARD SEED, SUBSTATION SSL SHORT SLOTTED HOLES SSMH SANITARY SEWER MANHOLE/MAINTENANCE HOLE SSS SANITARY SIDE SEWER SST STAINLESS STEEL ST-# METAL STAIRS TYPE ST STREET, SOUND TRANSIT, SPIRAL TO TANGENT STA STATION(ING) STD STANDARD, STANDARD TREE STE STEAM STIFF STIFFENER STIRR STIRRUP(S) STL STEEL, STREET LIGHT STMB STREAM BUFFER STN-# STONE PANEL TYPE STOR STORAGE STP STEEL PIPE, DUCT, CONDUIT STR STAIR STRUCT STRUCTURE(AL) STU SHOCK TRANSMISSION UNIT SU STUB UP SUB SUBSTATION SUPT SUPPORT SURF SURFACE SUSP SUSPENDED SVC,SVCS SERVICE(S) SW SHEARWALL, SIDEWALK, SOUTHWEST, SWITCH SWA SINGLE WIRE ANCHOR SWBD SWITCHBOARD SWFT SINGLE WIRE FIXED TERMINATION (OCS) SWGR SWITCH GEAR SWH SWITCH HEATER SWHT SWITCH HEATER TRANSFORMER SWPPP STORM WATER POLLUTION PREVENTION PLAN SWR SEWER SYM SYMBOL, SYMMETRICAL SYS SYSTEM T T TOP, TANGENT, TELEPHONE, TOWNSHIP, THERMOSTAT, TRANSVERSE, TRIP T&B TOP AND BOTTOM T/TOP OF T/C TRACK CENTERS, TOP OF CURB T/EMB TOP OF EMBEDMENT T/F TOE OF FROG, TOP OF FOUNDATION T/G TOP OF GROUND LINE T/L TAX LOT T/LR TOP OF LOW RAIL T/P TOP OF PAVEMENT T/R TOP OF RAIL TA-# TOILET ACCESSORY TYPE TAN TANGENT TB THRUST BLOCK, TAP BOX, TERMINAL BLOCK TBB TELECOMMUNICATIONS BACK BOARD TBD TO BE DETERMINED TBF TUNNEL BOOSTER FAN TBM TUNNEL BORING MACHINE TBR TO BE REMOVED TC-# TERRA COTTA RAINSCREEN SYSTEM Tc TANGENT DISTANCE FROM SC OR CS TO PI Tc1 SUFFIX (1) DENOTES DATA FOR FIRST TANGENT OF A COMPOUND CURVE Tc2 SUFFIX (2) - SAME AS ABOVE, SECOND TANGENT OF COMPOUND CURVE TC TOP OF CURB, TRAFFIC CONTROLLER BOX (UNDERGROUND), TRACK CIRCUIT TCAL TEMPORARY CONSTRUCTION AIRSPACE LEASE TCB TRAFFIC CONTROLLER BOX (ABOVE GROUND) TCE TEMPORARY CONSTRUCTION EASEMENT TCR TRAIN CONTROL ROOM TD TELEPHONE DUCT, TRENCH DRAIN, TRACK DAMPER TDD TELECOMMUNICATIONS DISPLAY DEVICE TDM TRANSPORTATION DESIGN MANUAL TYP TYPICAL, TYPICAL AT ALLTETRACTION ELECTRIFICATION TEL TELEPHONE TELECOMM TELECOMMUNICATION TEMP TEMPORARY, TEMPERATURE TERM TERMINAL TES TRACTION ELECTRIFICATION SYSTEM TESC TEMPORARY EROSION SEDIMENT CONTROL TF TOP FACE, TEMPERATURE FAHRENHEIT, TRACK FEET TFD TUNNEL FAN DAMPER TG TELEGRAPH, TOP OF GRADE, TRANSFER GRILLE, TOP OF GRATE TH THICKNESS, THRESHOLD THK THICK(NESS) THRD THREADED TI TENANT IMPROVEMENTS TJB TRAFFIC JUNCTION BOX TL TENSION LENGTH TMH TELEPHONE MANHOLE TO TURNOUT, TOP OF TOB TOP OF BEAM TOC TOP OF CONCRETE, TOP OF STRUCTURAL CONCRETE TOD TRANSIT ORIENTED DEVELOPMENT, TOP OF DUCT TOF TOP OF FOOTING TOG TOP OF GRADE TOP TOP OF PIPE TOR TOP OF RAIL TORW TOP OF RETAINING WALL TOS TOP OF SLAB, TOP OF STRUCTURE, TOP OF STEEL TOT TOTAL TOW TOP OF WALL TP TOTAL PRESSURE, TRAP PRIMER TPO-# THERMOPLASTIC POLYOLEFIN ROOFING TPSS TRACTION POWER SUBSTATION TR TRACK RELAY TRAC TRACTION TRANSF TRANSFORMER TRANSV TRANSVERSE TRD TREAD TRK TRACK Ts1 TANGENT DISTANCE FROM TS TO PI Ts2 TANGENT DISTANCE FROM ST TO PI TS TRAFFIC SIGNAL, TEST STATION, TANGENT TO SPIRAL, STRUCTURAL TUBING, TERMINAL STRIP TSH TOP OF SIGNAL HEAD TSOE TEMPORARY SUPPORT OF EXCAVATION TSP TOTAL STATIC PRESSURE TT TRANSFER TRIP, TRACK TRANSFORMER TTC TELEPHONE TERMINAL CABINET TV TELEVISION/CABLE TELEVISION TVF TUNNEL VENTILATION FAN TVM TICKET VENDING MACHINE TVOH TELEVISION OVERHEAD TVS TUNNEL VENTILATION SHAFT TW THERMITE WELDING, TOP OF WALL TW PR TWISTED PAIR TWA TIE WIRE ANCHOR TWC TRAIN TO WAYSIDE COMMUNICATION TWM TACTILE WARNING MATERIAL WCL WALL CONTROL LINE WCO WATER CLEANOUT, WALL CLEANOUT WE WESTBOUND TO EASTBOUND WD WOOD WF WIDE FLANGE (BEAM) WF-# WALL FINISH TYPE WG WATER GAUGE WGR-# WATER AND GRAFFITI REPELLANT - TYPE WH WATER HEATER WHDM WATT-HOUR DEMAND METER WHM WATT-HOUR METER WI WROUGHT IRON WID WIDTH WIN WINDOW WIP WROUGHT IRON PIPE WK WORK WL WORK LINE, WIND LOAD WLD WELDED WM WATER METER, WATER MAIN WMH WATER MANHOLE WOM WOMEN WP WORK POINT, WEATHERPROOF WPM WATERPROOFING MEMBRANE WP-# WATERPROOFING SYSTEM WQ WATER QUALITY WR WATER RESISTANT WRC-1 WATER REPELLANT COATING TYPE WS WATER STOP WSDOT WASHINGTON STATE DEPARTMENT OF TRANSPORTATION WSH WASH, WASHER WSP WELDED STEEL PIPE, WET STANDPIPE RESTORED SCRUB-SHRUB WETLAND WT WIDE FLANGE STEEL "T" SECTION, WEIGHT, WARNING TIME WT-# WALL TILE TYPE WUTC WASHINGTON UTILITIES AND TRANSPORTATION COMMISSION WV WATER VALVE WWF WELDED WIRE FABRIC STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL GENERAL ABBREVIATIONS BT120-GZN005 BT120 E. GOLLER C. SAXE M. FOLWELL J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS ABBREVIATIONS (CONT'D)ABBREVIATIONS (CONT'D) No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 11 / 1 8 / 2 4 | 1 0 : 2 6 A M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z N 0 0 1 - 0 0 5 . D W G S1-BT120-GZN001-005 FACILITY ID: 12/04/2024 0015 RTA/CN 0205-24 X - # - X - DATUM NAVD '88 ALL DIMENSIONS SHOWN IN FEET UNLESS OTHERWISE DESIGNATED. SCALE BAR (SCALE AS NOTED ON SHEET) NAVD 88 DATUM N NORTH ARROW SCALE IN FEET 0 (CUSTOM) # ### DETAIL TITLE SCALE: # XX ELEVATION TITLE SCALE: X XX ELEVATION TITLE SCALE: X - DETAIL TITLE SCALE: # - SECTION SCALE: X XX SECTION TITLE SCALE: X - SECTION DESIGNATION (LETTER) SECTION CUT ON THE SAME SHEET ONLY ELEVATION CUT ON THE SAME SHEET ONLY ELEVATION DESIGNATION (LETTER) ELEVATION DESIGNATION (LETTER) DRAWING NUMBER OF FIRST SHEET WHERE THE ELEVATION IS CUT FROM SECTION DESIGNATION (LETTER) # - SYMBOLS NB 000+00 27 5 . 2 32 0 . 1 2 PROPOSED ELEV OR PGL (T/LR)EXIST ELEV TYPICAL PROFILE ELEVATION DATA ELEVATION DESIGNATION (LETTER) DRAWING NUMBER OF SHEET WHERE THE ELEVATION IS SHOWN (DASH IF ON SAME SHEET ONLY) SECTION DESIGNATION (LETTER) DRAWING NUMBER OF SHEET WHERE THE SECTION IS SHOWN (DASH IF ON SAME SHEET ONLY) DETAIL DESIGNATION (NUMBER) DRAWING NUMBER OF SHEET WHERE THE DETAIL IS SHOWN (DASH IF ON SAME SHEET ONLY) DETAIL DESIGNATION (NUMBER) DETAIL DESIGNATION (NUMBER) DASH IF FROMSAME SHEET ONLY LEGEND NOTE: HATCH PATTERNS AND SYMBOLS MAY BE SHOWN AT DIFFERENT ORIENTATIONS AND/OR OVERLAP ON DRAWINGS. PERMANENT EASEMENT CONCRETE SIDEWALK / CONCRETE PAVEMENT GRAVEL SURFACING TEMP CONSTRUCTION EASEMENT (TCE) TEMP CONSTRUCTION AIRSPACE LEASE (TCAL) GUIDEWAY EASEMENT OVERLAY FEE ACQUISITION ACCESS EASEMENT REMOVE EXISTING STRUCTURE REMOVE CONCRETE PAVEMENT TIEBACK/SOILNAIL EASEMENT HMA PAVEMENT PERMANENT WSDOT AIRSPACE LEASE (ASL)REMOVE BY OTHERS TEMP ENVIRONMENTAL MONITORING EASEMENT AREA IMPACTED BY EXISTING EXCAVATION SUPPORT SYSTEM CONSERVATION EASEMENT WETLAND TEMPORARY CRANE SWING EASEMENT PROPOSED RESOURCE CONSERVATION AREA DRAWING NUMBER OF FIRST SHEET WHERE THE SECTION IS CUT FROM DRAWING NUMBER OF FIRST SHEET WHERE THE DETAIL IS SHOWN REMOVE ASPHALT PAVEMENT EMBANKMENT BALLAST SUBBALLAST POROUS CONCRETE NOT IN CONTRACT EXISTING CONCRETE SIDEWALK / EXISTING CONCRETE PAVEMENT EXISTING WETLAND R STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL GENERAL SYMBOLS AND LEGEND BT120-GZN006 BT120 E. GOLLER C. SAXE M. FOLWELL J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 11 / 1 8 / 2 4 | 1 0 : 2 6 A M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z N 0 0 6 . D W G S1-BT120-GZN006 FACILITY ID: Xrefs: xBRT-CUD05-TB22x34 GB-SEAL-JKH53550 12/04/2024 0016 RTA/CN 0205-24 SYMBOLS UNK FACILITY TO ABANDON FACILITY TO REMOVE TRAFFIC SIGNAL POLE TRAFFIC SIGNAL POLE WITH LUMINAIRE CAMERA CABLE VAULT\INFORMATION TECHNOLOGY SERVICES DOUBLE LUMINAIRE STANDPIPE WITH HOSE VALVE WATER METER WATER MANHOLE THRUST BLOCK FIRE HYDRANT FIRE DEPARTMENT CONNECTION BUTTERFLY VALVE, M.J. GATE VALVE IRRIGATION CONTROL VALVE GAS VALVE ELECTRIC VAULT ELECTRIC MANHOLE ELECTRIC METER UTILITY POLE UTILITY POLE ANCHOR UTILITY POLE W/ LIGHT TELEPHONE RISER UTILITY VAULT UNKNOWN VAULT TELEPHONE MANHOLE CABLE TV MANHOLE FIBER OPTIC MANHOLE TELEPHONE VAULT FIBER OPTIC VAULT CABLE TV VAULT TRAFFIC CABINET SAN. SEWER CLEAN OUT SAN. SEWER MANHOLE WSDOT SYMBOLS VMS CH CV B PB T VMS/LED CABINET VARIABLE MESSAGE SIGN ADVANCED WARNING SIGN CCTV CONTROLLER CABINET COMMUNICATIONS HUB ITS CABLE VAULT INDUCTION LOOP VEHICLE DETECTOR (TYPE R1) TRAFFIC CONTROLL GATE TYPE 1 JUNCTION BOX TYPE 3 JUNCTION BOX NEMA 4X JUNCTION BOX TYPE 6 JUNCTION BOX NEMA 7 JUNCTION BOX JUNCTION BOX TYPE A JUNCTION BOX TYPE B ELECTRIC SERVICE SERVICE CABINET (SUA) MOTORIST AID TELEPHONE LIGHT STANDARD, 2-ARM, METAL LIGHT STANDARD, SINGLE ARM, METAL HIGH MAST LIGHT STANDARD, 4 ARMS, METAL HIGH MAST LIGHT STANDARD, 3 ARMS, METAL ITS PULL BOX ELECTRONIC SIGN TRANSFORMER CABINET UNDERDECK LUMINAIRE HARS CONTROLLER CABINET GUY POLE W/ ANCHOR TYPE 2 INDUCTION LOOP VEHICLE DETECTOR OVERHEAD CHANGEABLE MESSAGE SIGN (CMS) TYPE 2 JUNCTION BOX TYPE 1 SIGNAL STANDARD WITH SIGNAL HEADS CCTV CAMERA TYPE 2 SIGNAL POLE WITH 2 SIGNALS OR FO OE OE E C OC OET OETC EFO OEC OEFO TC TC OETFO CABLE TV UNDERGROUND CABLE TV OVERHEAD ELECTRIC UNDERGROUND ELECTRIC/FIBER OPTIC UNDERGROUND ELECTRIC OVERHEAD ELECTRIC/CABLE TV OVERHEAD ELECTRIC/TELEPHONE OVERHEAD ELECTRIC/TELEPHONE/CABLE OVERHEAD ELECTRIC/FIBER OPTIC OVERHEAD FIBER OPTIC TELEPHONE/CABLE/FIBER OPTIC TELEPHONE/CABLE TV ET ET ELECTRIC/TELEPHONE G GAS W SD OT OT T UD SS UTILITY LINE SANITARY SEWER STORM DRAIN TELEPHONE TELEPHONE OVERHEAD WATER TELEPHONE/FIBER OPTIC DUCT BANK WATER STORM DRAIN SANITARY SEWER ELECTRIC DUCT BANK 24" W 24" SD 24" E CONCRETE CULVERT24" CC 24" G GAS TELEPHONE DUCT BANKT (2' W X 2' D DB) T&FO (2' W X 2' D DB) 24" SS PEDESTRIAN SIGNAL HEAD SIGNAL CONTROLLER CABINET SERVICE CABINET COUPLING AIR RELEASE VALVE PROPOSED W OR OR EFO OEC OEFO TC TCFO EXISTING E (2'W X 2'D DB) 24" SS 24" SD 24" W T&FO (2'W X 2'D DB) OC C E OE FO G T OT SD W 24" G OET 24" CC OEC T (2'W X 2'D DB) ET SS X FENCE X X C F XXX SAW CUT MAJOR CONTOUR TOP OF CUT MINOR CONTOUR GUARD RAIL TOE OF FILL CONTRACTOR WORKING LIMITS CLEARING AND GRUBBING LIMITS CONCRETE BARRIER XXX EXISTING PROPOSED EXISTING PROPOSED STORM DRAIN CASING CONSTRUCTION FENCE GRADE LINE TYPE 1, PS, OR PEDESTRIAN PUSHBUTTON POLE MODIFIED TYPE 2 INDUCTION LOOP VEHICLE DETECTOR CONTROLLER CABINET (RAMP METER OR DATA STATION) EXISTING PROPOSED WALL RAILING OCS POLE FOUNDATION OCS DOWN GUY FOUNDATION UNDERDRAIN UD IMPACT AREA LIMIT UNDERGROUND UTILITIES W/ A DIAMETER OR WIDTH 24" & GREATER ACOUSTIC PANELS NOISE WALLS AP AP NW ^^^ GUY WIRE ////// ///////// )()( || l l l NW NW UTILITY SETTLEMENT POINT SURFACE SETTLEMENT POINT USP SSP DITCH LINE ESTIMATED STREAMES MECHANICAL FIRE PIPE DSP CVITS W ICVICV EVEV E E EMEM UTUT T C FOFO C T T FOFO C C TCBTCB CO CO JUNCTION BOX TYPE I RAILROAD CROSSING GATE TCBTCB STORM DRAIN CULVERT STORM DRAIN CLEAN OUT ROCK PROTECTION OUTFALL STORM DRAIN CATCH BASIN STORM FACILITY ACCESS LID CO STORM DRAIN GRATE INLET MAINTENANCE HOLE STORM TRENCH DRAIN STORM AERIAL DRAIN STORM DOWNSPOUT CURB CUT INLET > BALLAST WALL RETAINING WALL ALIGNMENT (REVERSIBLE CUT/FILL) ((( FDC CONNECTION MONITORING WELL OHWM Axx Axx ///////////////////////////// MISCELLANEOUS LINETYPES LANDSCAPE PROTECTION FENCING No. ST ROW NUMBER PARCEL NUMBER (TAX ACCOUNT NO.) No. SURVEY MONUMENT TREE INVENTORY NUMBER R/W NO. 123 44 John Doe MISCELLANEOUS SYMBOLS WCL WCL /////////BUILDING OUTLINE ///////// STMB STMB COS INLET PIPE LABEL FLOW ARROW < //////// //////////// PERMANENT EASEMENT LINE TEMPORARY EASEMENT LINE PROPOSED RIGHT-OF-WAY/PROPERTY LINE LIGHT RAIL TRANSIT WAY FUTURE NOT-IN-CONTRACT EXISTING RIGHT-OF-WAY LINE EXISTING PROPERTY/LOT LINE SECTION LINE EXISTING CENTERLINE EXISTING EASEMENT LINE WSDOT LIMITED ACCESS LINE EXISTING ORDINARY HIGH WATER MARK EXISTING WETLAND BOUNDARY EXISTING WETLAND BUFFER WSDOT COMPATIBILITY LINE STREAM BUFFER STORM DRAIN - PIPE CASING STORM DRAIN - PROPOSED CROSSING STORM DRAIN - DITCH TOE BOUNDS STORM DRAIN - DITCH CL ABANDON UTILITY REMOVE UTILITY STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 GENERAL GENERAL SYMBOLS AND LEGEND BT120-GZN007 BT120 E. GOLLER C. SAXE M. FOLWELL J. HARPER 0 12/10/2024 EDG LDG JKH ISSUED FOR BID NTS No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 11 / 1 8 / 2 4 | 1 0 : 2 6 A M | C S A X E C: \ P W W O R K I N G \ J A C O B S _ B & I \ J E G _ E X - S A X E C \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - G Z N 0 0 7 . D W G S1-BT120-GZN007 FACILITY ID: Xrefs: xBRT-CUD05-TB22x34 GB-SEAL-JKH53550 12/04/2024 0017 RTA/CN 0205-24 1. SNOW LOAD DATA GROUND SNOW LOAD , Pg: 20 PSF SNOW EXPOSURE FACTOR, Ce: 1.0 SNOW LOAD IMPORTANCE FACTOR, Is: 1.0 THERMAL FACTOR, Ct : 1.2 RAIN ON SNOW: 5 PSF MIN ROOF SNOW LOAD: 25 PSF 2.WIND DESIGN DATA ULTIMATE DESIGN WIND SPEED, Vult:110 MPH RISK CATEGORY: II WIND EXPOSURE CATEGORY: B INTERNAL PRESSURE COEFFICIENT (ENCLOSED): ±0.18 1.THE FOUNDATION DESIGN IS BASED UPON THE "SUPPLEMENTAL GEOTECHNICAL AND PAVEMENT RECOMMENDATIONS" GEOTECHNICAL REPORT PREPARED BY THE GENERAL ENGINEERING CONSULTANT. REPORT NUMBER D3458632 DATED DECEMBER 2024. 2.ALLOWABLE NET BEARING CAPACITY:2,000 PSF 3.ALLOWABLE NET POST-LIQUEFACTION BEARING CAPACITY:800 PSF 4.FROST DEPTH:1'-0" 5.ALLOWABLE VERTICAL PILE CAPACITY:80,000 LB 6.ALLOWABLE LATERAL PILE CAPACITY:15,000 LB APPLICABLE CODES AND STANDARDS 1.ALL LOCAL, STATE, AND FEDERAL AGENCIES HAVING JURISDICTION OVER THIS PROJECT a.CITY OF RENTON STRUCTURAL DESIGN CRITERIA 2.2021 INTERNATIONAL BUILDING CODE (2021 IBC) 3.AMERICAN CONCRETE INSTITUTE (ACI): a.ACI 318-19 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE 4.AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC): a.AISC 360-16 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS b.AISC 341-16 SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS c.2014 RCSC SPECIFICATION FOR HIGH-STRENGTH BOLTS 5.AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE): a.ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES 6.ASTM INTERNATIONAL (ASTM): a.ALL MATERIAL STANDARDS NOTED 7.AMERICAN WELDING SOCIETY (AWS): a.AWS D1.1-2015 STRUCTURAL WELDING CODE -STEEL b.AWS D1.3-2008 STRUCTURAL WELDING CODE -SHEET STEEL c.AWS D1.4-2011 STRUCTURAL WELDING CODE -REINFORCING STEEL d.AWS D1.8-2016 STRUCTURAL WELDING CODE -SEISMIC SUPPLEMENT 8.STEEL DECK INSTITUTE (SDI): a.SDI CRD-2017 STANDARD FOR STEEL ROOF DECK DESIGN LOADS FOUNDATION DESIGN MATERIALS OF CONSTRUCTION 1.NORMAL WEIGHT CONCRETE GENERAL STRUCTURAL CONCRETE f'c = 4,500 psi 2.REINFORCING STEEL ASTM A615 GR 60 Fy = 60 ksi 3.WELDABLE REINFORCING STEEL ASTM A706 GR 60 Fy = 60 ksi 4.WELDED WIRE REINFORCING ASTM A1064 Fy = 70 ksi 1.ALL EARTHWORK AND SITE PREPARATION SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE SPECIFICATIONS AND THE GEOTECHNICAL REPORT. ALL FOUNDATION EXCAVATIONS SHALL BE OBSERVED AND APPROVED BY THE GEOTECH. 2.ANY EXISTING FILLS OR UNSUITABLE SOILS AS DETERMINED BY THE GEOTECH SHALL BE EXCAVATED AND REPLACED WITH PROPERLY COMPACTED FILL. EARTHWORK AND FOUNDATIONS 1.STRUCTURAL DRAWINGS SHALL NOT BE SCALED. PRINTED DIMENSIONS HAVE PRECEDENCE OVER SCALED DRAWINGS AND LARGE SCALE OVER SMALL. 2.ALL DRAWINGS AND SPECIFICATIONS ARE CONSIDERED TO BE A PART OF THE CONTRACT DOCUMENTS. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR LOCATION AND SIZE OF OPENINGS, BLOCKOUTS, FLOOR DEPRESSIONS, CURBS, DIMENSIONS, ETC. NOT INDICATED ON THE STRUCTURAL DRAWINGS. THE LOCATION AND SIZE OF MECHANICAL AND ELECTRICAL OPENINGS IN SLABS, WALLS AND DECKS SHALL BE COORDINATED BY THE CONTRACTOR. PROVIDE ALL ADDITIONAL FRAMING OR REINFORCING TO ACCOMMODATE OPENINGS AS REQUIRED BY THE APPLICABLE STANDARD DETAILS SHOWN ON THE STRUCTURAL DRAWINGS. NO HOLES, NOTCHES, BLOCKOUTS, ETC. ARE ALLOWED IN STRUCTURAL MEMBERS UNLESS DETAILED ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER. 3.WHERE DIMENSIONS ARE PROVIDED FOR OPENINGS, BLOCKOUTS, FLOOR DEPRESSIONS, CURBS, ETC., BUT MAY BE AFFECTED BY THE EQUIPMENT PURCHASED, THE CONTRACTOR SHALL VERIFY THE INFORMATION PROVIDED PRIOR TO CONSTRUCTION. 4.PROVIDE CONCRETE EQUIPMENT PADS AND INERTIAL BASES FOR MECHANICAL AND ELECTRICAL INSTALLATIONS. CONSTRUCT PADS AND BASES IN ACCORDANCE WITH THE TYPICAL DETAILS. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LIMITS AND LOCATIONS. 5.THE CONTRACTOR SHALL VISIT THE SITE AND GET FAMILIAR WITH EXISTING CONDITIONS, CHECK AND VERIFY EXISTING DIMENSIONS AND TAKE ADDITIONAL MEASUREMENTS AS NEEDED. NOTIFY THE ARCHITECT OF ANY DISCREPANCY BETWEEN ACTUAL CONDITIONS AND INDICATED CONDITIONS. MODIFICATION OF DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL OF THE ARCHITECT OR STRUCTURAL ENGINEER. 6.CONTRACTOR SHALL PROVIDE AND BE RESPONSIBLE FOR THE PROTECTION AND REPAIR OF ADJACENT EXISTING SURFACES AND AREAS WHICH MAY BE DAMAGED BY NEW WORK. 7.ALL COLUMNS AND FOUNDATIONS, UNLESS NOTED OTHERWISE, SHALL BE CENTERED ON GRIDLINES IN EACH DIRECTION. BEAMS SHALL BE EQUALLY SPACED BETWEEN COLUMN CENTERLINES UNLESS NOTED OTHERWISE. 8.TYPICAL DETAILS SHALL APPLY IN GENERAL CONSTRUCTION UNLESS SPECIFICALLY DETAILED. WHERE NO DETAILS ARE GIVEN, CONSTRUCTION SHALL BE AS SHOWN FOR SIMILAR WORK. GENERAL CONSTRUCTION NOTES 3. EARTHQUAKE DESIGN DATA RISK CATEGORY II SEISMIC IMPORTANCE FACTOR, Ie 1.0 MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS Ss 1.530 g S1 0.417 g SITE CLASS E DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS Sds 1.224 g Sd1 0.658 g SEISMIC DESIGN CATEGORY D 3.1 SHELTER CANOPY BASIC FORCE RESISTING SYSTEM: STEEL SPECIAL CANTILEVER COLUMN RESPONSE MODIFICATION COEFFICIENT, R: 2.50 OVERSTRENGTH FACTOR, ΩO :1.25 DEFLECTION AMPLIFICATION FACTOR, Cd: 2.50 SEISMIC RESPONSE COEFFICIENT, Cs: 0.263 DESIGN BASE SHEAR PER COLUMN, V: 5 KIPS ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE 3.2 CORE FACILITIES BASIC FORCE RESISTING SYSTEM: STEEL ORDINARY CONCENTRICALLY BRACED FRAMES STEEL ORDINARY MOMENT FRAMES RESPONSE MODIFICATION COEFFICIENT, R: 3.25 OVERSTRENGTH FACTOR, Ωo:3.00 DEFLECTION AMPLIFICATION FACTOR, Cd: 3.25 SEISMIC RESPONSE COEFFICIENT, Cs: 0.377 DESIGN BASE SHEAR, V: 104 KIPS ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE 3.EXTREME CARE SHALL BE EXERCISED WHEN EXCAVATING OR GRADING ADJACENT TO EXISTING STRUCTURES OR IMPROVEMENTS SO AS NOT TO DAMAGE OR UNDERMINE FOUNDATIONS, WALLS, SLABS, UTILITIES, ETC. 4.DO NOT EXCAVATE BELOW THE BEARING ELEVATION OF ANY COMPLETED FOOTING NOR ANY CLOSER TO THE FOOTING THAN A SLOPE OF TWO HORIZONTAL (MEASURED FROM EDGE OF FOOTING TO NEAREST POINT IN EXCAVATION) TO ONE VERTICAL. 5.HORIZONTAL CONSTRUCTION JOINTS IN COLUMN FOOTINGS, SLABS ON GRADE AND MAT FOUNDATIONS ARE NOT PERMITTED. 6.PROVIDE DOWELS FOR ALL WALLS EMBEDDED INTO COLUMN FOOTINGS, MAT FOUNDATIONS AND GRADE BEAMS. DOWELS SHALL BE THE SAME SIZE AND SPACING AS VERTICAL WALL REINFORCEMENT. 7.BOTTOM OF ALL FOOTINGS SUBJECT TO FROST SHALL BE PLACED AT OR BELOW FROST DEPTH. 11.CONTINUOUS REINFORCEMENT IN WALLS AND FOOTINGS MAY BE SPLICED AS REQUIRED, PROVIDED THAT BARS ARE OF THE LONGEST PRACTICAL LENGTH AND ALL SPLICES ARE SHOWN ON THE REINFORCING BAR SHOP DRAWINGS. SPLICES ARE TO BE STAGGERED WHEN POSSIBLE. PROVIDE LAP SPLICES AND DEVELOPMENT LENGTHS IN ACCORDANCE WITH THE DEVELOPMENT LENGTH AND LAP SPLICE SCHEDULE. USE CLASS B LAP SPLICES UNLESS NOTED OTHERWISE. 12.CORING OF SLABS, BEAMS, COLUMNS, OR WALLS IS NOT PERMITTED. PROVIDE SLEEVES FOR ALL PENETRATIONS PRIOR TO PLACING CONCRETE. 1.LOCATION OF CONSTRUCTION JOINTS OR POUR JOINTS SHALL BE AS INDICATED ON APPROVED SHOP DRAWINGS. 2.ALL CONCRETE SHALL BE VIBRATED DURING PLACEMENT. 3.PROVIDE 3/4" CHAMFER ON ALL EXPOSED CONCRETE CORNERS. 4.NO STAKES, STEEL OR WOOD, SHALL BE PERMITTED IN ANY CONCRETE POUR. SUSPEND FORMS FROM ABOVE GRADE. 5.ANCHOR RODS, DOWELS, REINFORCING STEEL, INSERTS, ETC, SHALL BE SECURELY TIED IN PLACE PRIOR TO POURING CONCRETE. CONCRETE BLOCKS ONLY SHALL BE USED TO SUPPORT REINFORCING OFF GRADE. 6.ALL REINFORCEMENT SHALL BE DETAILED, FABRICATED AND PLACED IN ACCORDANCE WITH ACI 315. 7.PROVIDE MINIMUM CONCRETE COVERING FOR REINFORCEMENT AS FOLLOWS: A.CONCRETE DEPOSITED AGAINST EARTH:3" B.FORMED SURFACES EXPOSED TO WEATHER OR IN CONTACT WITH EARTH: REINFORCING #6 OR LARGER 2" REINFORCING LESS THAN #6 1 1/2" C.FORMED SURFACES IN BUILDING INTERIOR: BEAMS, GIRDERS, AND COLUMNS 1 1/2" D.SLABS, WALLS AND JOISTS: REINFORCING #11 OR SMALLER 3/4" REINFORCING #14 AND #18 1 1/2" CONCRETE AND REINFORCING STEEL ROOF DECK 1.PROVIDE STEEL ROOF DECKS THAT CONFORM TO THE REQUIREMENTS OF THE BUILDING CODE, SECTION 2210. 2.CUTTING AND FRAMING OF OPENINGS FOR OTHER TRADES SHALL BE THE RESPONSIBILITY OF THE TRADES INVOLVED. HOLES THAT ARE LOCATED AND DIMENSIONS ON THE DRAWINGS SHALL BE THE RESPONSIBILITY OF THE DECK ERECTOR. 3.ALL DECK SHALL HAVE A MINIMUM GAUGE OF 20, UNLESS INDICATED OTHERWISE ON THE STRUCTURAL DRAWINGS. STEEL DECK SHALL BE VERCO TYPE HSB-36, ASC TYPE B, OR APPROVED EQUAL. ALL DECK SHALL BE GRADE 50 STEEL. 4.DECK SHALL BE PLACED IN A TWO OR THREE SPAN CONDITION IN ALL LOCATIONS UNLESS NOT POSSIBLE DUE TO GEOMETRY. 5.DECKS SHALL HAVE MINIMUM 2" BEARING AT SUPPORTS. 6.SEE ARCHITECTURAL AND LIFE-SAFETY DRAWINGS FOR THE EXTENT OF FIREPROOFING. STEEL DECK TO BE SPRAY FIREPROOFED SHALL BE GALVANIZED, CLEANED, AND DEGREASED BEFORE SHIPPING. 7. CONTRACTOR SHALL DESIGN AND SUPPLY ALL ADDITIONAL MISCELLANEOUS METALS AND SYSTEM SUPPORT COMPONENTS THAT ARE REQUIRED TO SUPPORT ALL MECHANICAL, ELECTRICAL, AND PLUMBING/FIRE-PROTECTION SYSTEMS. SUCH SUPPORT COMPONENTS AND THEIR CONNECTIONS SHALL BE PROVIDED TO DIRECTLY AND CONCENTRICALLY IMPOSE LOADS ON THE PRIMARY STRUCTURE. A MAXIMUM LOAD OF 50 POUNDS MAY HANG FROM STEEL ROOF DECK. CONCRETE AND REINFORCING (CONT'D) 8.PROVIDE DOWELS OF SAME SIZE AND NUMBER FROM ADJACENT POUR, BOTH VERTICALLY AND HORIZONTALLY, TO MATCH TYPICAL REINFORCING SHOWN. LAPS TO BE IN ACCORDANCE WITH THE DEVELOPMENT LENGTH AND LAP SPLICE SCHEDULE. DOWELS SHALL BE CLEANED AFTER POUR. 9.FIELD WELDING OR BENDING OF REINFORCING IS NOT PERMITTED EXCEPT AS INDICATED ON THE DRAWINGS OR AS APPROVED BY THE STRUCTURAL ENGINEER. USE LOW HYDROGEN ELECTRODES GRADE E70 OR E90 AS REQUIRED. 10.APPROVED ELECTRICAL CONDUIT MATERIAL CAST WITHIN STRUCTURAL CONCRETE MEMBERS SHALL CONFORM TO ACI 318 UNLESS NOTED OTHERWISE AND TO THE FOLLOWING: A.PERMITTED CONDUIT SHALL BE PLACED INSIDE THE REINFORCING CAGE IN COLUMNS, WALLS, AND SLABS, AND BELOW REINFORCING IN SLABS ON GRADE. B. CONDUIT IN SLAB ON GRADE: DIAMETER OF A SINGLE CONDUIT OR TWO OR MORE VERTICALLY STACKED CONDUITS (INCLUDING CROSSOVERS) SHALL NOT EXCEED 1/3 THE THICKNESS OF THE SLAB. THE OUTSIDE DIMENSION OF TWO OR MORE ADJACENT CONDUITS SHALL NOT EXCEED TWICE THE DEPTH OF THE SLAB AND THE SEPARATION BETWEEN GROUPS OF CONDUITS SHALL NOT BE LESS THAN THE THICKNESS OF THE SLAB. C.DO NOT INSTALL CONDUIT IN PARKING GARAGE SLABS. D.DO NOT INSTALL CONDUIT IN BEAMS. 9.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE DESIGN AND CONSTRUCTION OF ALL FORMS, SHORING AND TEMPORARY BRACING. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE AND SAFETY OF WORKERS DURING CONSTRUCTION. A.DO NOT PLACE CONSTRUCTION MATERIALS OR OTHER CONSTRUCTION LOADS ON THE STRUCTURE SUCH THAT THE LOADS PLACED EXCEED THE CAPACITY OF THE STRUCTURE. B.TAKE INTO CONSIDERATION THAT FULL STRUCTURAL CAPACITY OF MANY STRUCTURAL MEMBERS IS NOT REALIZED UNTIL STRUCTURAL ASSEMBLY IS COMPLETE; THAT IS, UNTIL SLABS, DECKS, DIAGONAL BRACING AND SHEAR WALLS ARE INSTALLED. C.PROVIDE TEMPORARY BRACING AND GUYING TO PROVIDE STABILITY AND RESIST ALL LOADS TO WHICH THE PARTIALLY COMPLETED STRUCTURE MAY BE SUBJECTED INCLUDING ERECTION EQUIPMENT AND ITS OPERATION. ADEQUACY OF TEMPORARY BRACING AND GUYING FOR THIS PURPOSE IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. D.DO NOT BACKFILL AGAINST BASEMENT WALLS UNTIL FRAMED SLAB AND SLAB ON GRADE LOCATED TOP AND BOTTOM OF BASEMENT WALL HAVE BEEN PLACED AND HAVE REACHED THEIR 28-DAY DESIGN STRENGTH. 5.STRUCTURAL STEEL WIDE FLANGE & TEE SHAPES ASTM A992 Fy = 50 ksi ANGLES AND CHANNELS ASTM A36 Fy = 36 ksi PLATES ASTM A572 Fy = 50 ksi HSS RECTANGULAR & SQUARE ASTM A500 GR C Fy = 50 ksi HSS ROUND ASTM A500 GR C Fy = 45 ksi BOLTS ASTM A325 Fu = 120 ksi ANCHOR RODS ASTM F1554 GR 36 Fy = 36 ksi ANCHOR RODS ASTM F1554 GR 55 WELDABLE Fy = 55 ksi HIGH STRENGTH ANCHOR ROD ASSEMBLY: ANCHOR RODS ASTM F1554 GR 105 Fy = 105 ksi NUTS ASTM A563 GR D HEADED STUDS ASTM A108, TYPE B Fu = 65 ksi DEFORMED BAR ANCHORS ASTM F1554 GR 55 Fy = 55 ksi WELDING ELECTRODES E70XX STEEL ROOF DECKING (GALVANIZED) ASTM A653 G60 (Z180) ZINC COATING Fy = 50 ksi WEATHERED STEEL PLATES ASTM A242 Fy = 42 ksi 6.NON-SHRINK AND NON-METALLIC GROUT AT BASE/BRG PLATES AT 7 DAYS f'c = 4,000 psi AT 28 DAYS f'c = 8,000 psi STORY DRIFT 1.THE PRIMARY STRUCTURE WILL EXPERIENCE LATERAL MOVEMENTS BETWEEN ADJACENT FLOORS. THE STORY DRIFTS PERPENDICULAR AND/OR PARALLEL TO THE PRIMARY STRUCTURE ARE AS FOLLOWS: SHELTER CANOPY SERVICE LEVEL DESIGN STORY DRIFT STORY DRIFT ROOF 3/4"3 1/2" CORE FACILITIES SERVICE LEVEL DESIGN STORY DRIFT STORY DRIFT ROOF 3/4"3" STORY DRIFT (CONT'D) 2. BUILDING COMPONENTS SUCH AS EXTERIOR CLADDING, STAIRS, MISCELLANEOUS METALS, MEP SYSTEM SUPPORTS, INTERIOR METAL STUD FRAMING, AND ANY OTHER ELEMENT REQUIRED BY THE BUILDING CODE SHALL BE DESIGNED TO ACCOMMODATE THE PRIMARY STRUCTURE STORY DRIFTS WITH ANY APPLICABLE COMPONENT-SPECIFIC MODIFICATION PER CHAPTER 13 OF ASCE 7. SPECIAL INSPECTIONS 1.STRUCTURAL STEEL, WELDING, HIGH STRENGTH BOLTS, CONCRETE, ANCHORS CAST IN CONCRETE, ANCHORS POST- INSTALLED IN HARDENED CONCRETE, AND REINFORCING STEEL REQUIRE SPECIAL INSPECTIONS AND TESTING PER THE INTERNATIONAL BUILDING CODE SECTION 1705. 2.THIS WORK SHALL BE PERFORMED BY A SPECIAL INSPECTOR CERTIFIED BY THE AUTHORITY HAVING JURISDICTION TO PERFORM THE TYPES OF INSPECTIONS AND TESTS SPECIFIED. 3.THE TIMING AND FREQUENCY OF THE INSPECTIONS AND TESTING SHALL BE AS DESCRIBED IN THE CORRESPONDING TABLE OF THE INTERNATIONAL BUILDING CODE FOR EACH ELEMENT. 1.ANCHOR RODS SHALL BE AS NOTED IN THE MATERIALS OF CONSTRUCTION SECTION OF THE GENERAL NOTES, UNLESS NOTED OTHERWISE. PROVIDE ANCHOR RODS PREFABRICATED WITH CORRESPONDING DOUBLE HEAVY HEX NUTS ADDED AT EMBEDDED IN CONCRETE END. INSTALL PLATE WASHERS AND CORRESPONDING HEAVY HEX NUTS THAT SECURE THE BASE PLATE ASSEMBLY TO THE ANCHOR RODS. RIGID STEEL TEMPLATES SHALL BE USED TO LOCATE ANCHOR RODS WHILE PLACING CONCRETE. AT LEAST ONE TEMPLATE SHALL BE TOWARDS THE BOTTOM OF THE ANCHOR RODS. 2.LENGTH OF ANCHOR RODS SHALL BE ENOUGH TO PROVIDE THE MINIMUM EMBEDMENT SHOWN ON THE DRAWINGS, WHICH IS MEASURED FROM THE FACE OF CONCRETE TO THE NEAREST FACE OF THE NOTED DOUBLE NUT. ADDITIONALLY, ADEQUATE EXTENSION TO RECEIVE THE BASE PLATE WITH ADEQUATE THREAD PROJECTION FOR FULL NUT ENGAGEMENT SHALL BE PROVIDED. ANCHOR ROD INSTALLATION SHALL BE COORDINATED WITH REINFORCING, FORMWORK, AND CONDUIT WHERE APPLICABLE. LEVELING NUTS SHALL NOT BE USED EXCEPT AFTER EVALUATION BY THE CONTRACTOR'S ERECTION ENGINEER. 3.ANCHOR ROD NUTS SHALL BE INSTALLED TO A SNUG-TIGHT CONDITION. HEATING OR BENDING OF THE ANCHOR RODS OR BASE PLATE IS NOT ALLOWED. ANCHOR RODS R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 4 5 A M BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A.FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SZN001 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL GENERAL STRUCTURAL NOTESLPDDJPAE LPD AJF AE 12/10/2024 345ISSUED FOR BID 1 1 1 06/13/2025 ADDENDUM #1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 EXPANSION ANCHORS 1.EXPANSION ANCHORS SHALL HAVE A CURRENT EVALUATION REPORT ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH ACI 355.2. IN SEISMIC DESIGN CATEGORY C AND GREATER, THE EVALUATION REPORT SHALL INDICATE THE ANCHORS ARE QUALIFIED FOR EARTHQUAKE LOADING. ANCHORS SHALL BE HILTI KWIK BOLT TZ (ICC ES REPORTS ESR-1917) OR APPROVED EQUAL. 2.ANCHORS SHALL BE ZINC PLATED UNLESS SPECIFICALLY NOTED AS STAINLESS STEEL ON THE PLAN DETAILS. USE STAINLESS STEEL FOR ANCHORS EXPOSED TO WEATHER. 3.WHEN DETAILS OF SECTIONS INDICATE EXPANSION ANCHORS BUT NO SIZE, PROVIDE ANCHORS WITH 3/4" DIAMETER. 4.INSTALL ANCHORS IN ACCORDANCE WITH THE EVALUATION REPORT AND MANUFACTURER'S RECOMMENDATIONS. PROVIDE THE MINIMUM EMBEDMENT DEPTHS, SPACING, AND EDGE DISTANCE INDICATED IN THE SCHEDULE BELOW UNLESS NOTED OTHERWISE IN DOCUMENTS. CONSULT STRUCTURAL ENGINEER FOR DIRECTION WHEN SCHEDULE CANNOT BE MET. 5.WHEN INSTALLING DRILLED-IN-ANCHORS, USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE EXISTING REINFORCING BARS. WHEN INSTALLING THEM INTO CONCRETE WITH STRESSING TENDONS (POST-TENSIONED OR PRE- TENSIONED), LOCATE THE TENDONS BY USING A NON- DESTRUCTIVE METHOD PRIOR TO INSTALLATION. EXERCISE EXTREME CARE AND CAUTION AND MAINTAIN AT LEAST 1 INCH CLEAR BETWEEN THE TENDON AND THE ANCHOR. CUTTING A TENDON CAN CAUSE COLLAPSE. EXPANSION ANCHOR SCHEDULE KWIK BOLT TZ ANCHOR SCHEDULE ANCHORS INSTALLED IN CONCRETE F'c = 2,500 psi MIN ANCHOR MIN EFFECTIVE MIN EDGE MIN TEST DIAMETER EMBEDMENT DISTANCE SPACING TORQUE 3/8" 2"4 3/8"6" 25 LB-FT 1/2" 3 1/4"7 1/2"9 3/4" 40 LB-FT 5/8" 4"8 3/8"12" 60 LB-FT 3/4" 4 3/4"10"14 1/4" 110 LB-FT NOTE:CONSULT STRUCTURAL ENGINEER OF RECORD FOR DIRECTION WHEN MINIMUM EDGE DISTANCE AND SPACING CANNOT BE OBTAINED 6.TEST INSTALLED ANCHORS IN ACCORDANCE WITH THE ANCHOR SCHEDULE AND AS FOLLOWS: A.EXPANSION ANCHORS SHALL BE TESTED WITH A CALIBRATED TORQUE WRENCH THE TORQUE LISTED BELOW SHALL BE OBTAINED WITHIN HALF TURN OF THE NUT. B.TESTING SHALL BE DONE IN THE PRESENCE OF THE SPECIAL INSPECTOR. ANCHORS TESTED SHALL BE SELECTED AT RANDOM BY THE SPECIAL INSPECTOR. THE TESTING FREQUENCY SHALL BE AS FOLLOWS: a.100% OF ALL ANCHORS USED FOR STRUCTURAL APPLICATIONS. b.50% OF ANCHORS OR ALTERNATE BOLTS IN A GROUP USED FOR NON-STRUCTURAL APPLICATIONS SUCH AS EQUIPMENT ANCHORAGE. INCLUDE AT LEAST ONE-HALF THE ANCHORS IN EACH GROUP. c.10% OF ANCHORS USED FOR SILL PLATE ANCHORING. d.10% OF ANCHORS WHERE THE FACTORED DESIGN TENSION LOAD IS LESS THAN 100 LBS AND IS CLEARLY IDENTIFIED ON THE PLANS OR DETAIL C.TEST EQUIPMENT SHALL BE CALIBRATED BY AN APPROVED TESTING LABORATORY IN ACCORDANCE WITH STANDARD RECOGNIZED PROCEDURES. 11. E70XX ELECTRODES SHALL BE USED FOR ALL WELDING. THE WELDING OF E7018 OVER E70TG-K2 IS NOT ALLOWED. THE MIXING OF ANY OTHER PROCESSES AND WIRES MUST BE SUBMITTED TO THE STRUCTURAL ENGINEER OF RECORD FOR APPROVAL. THE USE OF E70-T4 IS NOT ALLOWED. IN GROOVE WELDS, FCAW FILLER METAL WIRE SHALL BE LIMITED TO 5/64" DIAMETER. SMAW WELDING ELECTRODES SHALL BE LIMITED TO 5/32" DIAMETER. 12.ALL SHOP AND FIELD WELDS SHALL BE PREQUALIFIED WELDS. ANY WELDS BEYOND THE RANGE OR TOLERANCE OR REQUIREMENTS FOR PREQUALIFICATION SHALL BE QUALIFIED BY TEST PER AWS D1.1 CLAUSE 4 PART B. WELDS AT BASE METALS OVER 2" IN THICKNESS ARE NOT ALLOWED AS PREQUALIFIED WELD JOINTS WITHOUT TESTING. 13.A WELDING PROCEDURE SPECIFICATION (WPS) PER AWS D1.1 SHALL BE DEVELOPED BY THE FABRICATOR/ERECTOR AND APPROVED BY THE STRUCTURAL ENGINEER OR HIS DESIGNEE. THE WPS SHALL INCLUDE THE WELDING PARAMETERS RECOMMENDED BY THE ELECTRODE MANUFACTURER. THE WPS MUST BE SUBMITTED AND APPROVED BEFORE ANY WELDING MAY BEGIN. ALLOW A MINIMUM OF FOUR WEEKS FOR THE REVIEW PROCESS 14.A PRE-CONSTRUCTION MEETING BETWEEN THE STRUCTURAL ENGINEER, THE FABRICATOR, THE ERECTOR, THE CONTRACTOR, AND THE INSPECTORS SHALL TAKE PLACE TO DISCUSS THE WELDING PROCEDURE SPECIFICATIONS (WPS) TO INSURE THE QUALITY OF WORK THAT THE DESIGNER OF RECORD HAS SPECIFIED. THE WELDING ELECTRODE MANUFACTURER'S SPECIFICATIONS SHOULD BE ATTACHED TO THE WPS ON ALL JOBS. ALL WELDERS AND INSPECTORS SHALL BE INSTRUCTED IN THE PROPER USE OF THE WPS AND SHALL ALSO BE INSTRUCTED TO RETAIN A COPY OF THE WPS. 15.TO ASSURE THE PROPER AMPERAGE AND VOLTAGE OF THE WELDING PROCESS, THE USE OF A HAND HELD CALIBRATED AMP AND VOLT METER SHALL BE USED. THIS EQUIPMENT SHALL BE USED BY THE FABRICATOR, ERECTOR AND THE INSPECTORS. AMPERAGE AND VOLTAGE SHALL BE MEASURED NEAR THE ARC. TRAVEL SPEED AND ELECTRODE STICK OUT SHALL BE VERIFIED TO BE IN COMPLIANCE WITH THE APPROVED WPS. 16.PREHEAT AND INTERPASS TEMPERATURES FOR THE SEISMIC FORCE-RESISTING SYSTEM: A.THE PREHEAT TEMPERATURES AND CONDITIONS GIVEN IN AWS D1.1-6, ANNEX I, TABLE I.2, SHOULD BE STRICTLY OBSERVED USING A MEDIUM RESTRAINT LEVEL AND A MINIMUM SUSCEPTIBILITY INDEX OF "D". EXCEPTION: PLATES 2" AND THICKER AND GROUP 4 AND 5 SHAPES SHALL BE PREHEATED TO 300 DEG F. B.PREHEAT TEMPERATURES SHOULD BE MEASURED AT A DISTANCE FROM THE WELD EQUAL TO THE THICKNESS OF THE PART BEING WELDED, BUT NOT LESS THAN THREE INCHES, IN ANY DIRECTION INCLUDING THE THROUGH THICKNESS OF THE PIECE UNO IN THE CONTRACT DOCUMENTS. WHERE PLATES ARE OF DIFFERENT THICKNESS, THE PRE-HEAT REQUIREMENT FOR THE THICKER PLATE SHALL GOVERN. MAINTENANCE OF THESE TEMPERATURES THROUGH THE EXECUTION OF THE WELD (I.E. THE INTERPASS TEMPERATURE) IS ESSENTIAL. MAXIMUM INTERPASS TEMPERATURES SHOULD BE LIMITED TO 550 DEGREES F FOR PRE-QUALIFIED WPS, FOR FRACTURE-CRITICAL APPLICATIONS. HIGHER INTERPASS TEMPERATURES COULD BE EMPLOYED IF THOSE HIGHER TEMPERATURE LIMITS ARE QUALIFIED BY TEST. 17.A WELDING SEQUENCE SHALL BE DEVELOPED BY THE FABRICATOR/ERECTOR AND APPROVED BY THE STRUCTURAL ENGINEER OR HIS DESIGNEE FOR ALL WELDING TO BE DONE FOR THE SEISMIC FORCE-RESISTING SYSTEM. 18.NON-DESTRUCTIVE TESTING OF WELDED CONNECTIONS SHALL BE PERFORMED AT BRACING CONNECTION FILLET WELDS AND AT ALL COMPLETE OR PARTIAL JOINT PENETRATION GROOVE WELDS DESIGNATED TO BE A PART OF THE SEISMIC FORCE-RESISTING SYSTEM: A.WELDED CONNECTIONS SHALL BE TESTED BY NON-DESTRUCTIVE METHODS FOR COMPLIANCE WITH AISC 341, CHAPTER J. ULTRASONIC TESTING SHALL BE IN ACCORDANCE WITH AWS D1.1 AND D1.8. THIS TESTING SHALL BE PERFORMED BY AN APPROVED TESTING LABORATORY. B.ANY MATERIAL DISCONTINUITIES SHALL BE ACCEPTED OR REJECTED ON THE BASIS OF DEFECTIVE RATING IN ACCORDANCE WITH THE (LARGER REFLECTOR) CRITERIA OF AWS D1.1, CLAUSE 6.13. C.INSPECTORS SHALL BE QUALIFIED IN ACCORDANCE WITH AWS D1.1 CHAPTER 6. D.IN ADDITION TO THE REGULAR INSPECTIONS, A RE-INSPECTION SHALL BE DONE A MINIMUM OF 48 HOURS AFTER COMPLETE JOINT PENETRATION WELDING ON COLUMN FLANGES WITH A THICKNESS OF 3" OR GREATER. STRUCTURAL STEEL (CONT'D) ADHESIVE ANCHORS AND DOWELS 1.REINFORCING BAR DOWELS, REINFORCING BARS, THREADED RODS, BOLTS, ETC WHICH ARE INDICATED AS ADHESIVE ANCHOR OR ADHESIVE DOWELS SHALL BE ACCOMPLISHED USING HILTI HIT-RE 500 V3 INTO CONCRETE OR HIT-HY 70 FOR SOLID MASONRY (ICC ESR-4688 OR ESR-4143, RESPECTIVELY) OR APPROVED EQUAL. 2.DRILL, BRUSH, AND CLEAN ALL HOLES, AND INSTALL ALL ANCHORS IN COMPLETE ACCORDANCE WITH MANUFACTURER'S PUBLISHED RECOMMENDATIONS, AS WELL AS ALL APPLICABLE BUILDING CODES OR ENGINEERING REPORTS. 3.ADHESIVE ANCHORS AND DOWELS SHALL BE INSTALLED BY ACI CERTIFIED INSTALLERS. 1.STEEL FRAMING DESIGNATIONS AND SYMBOLS ARE DEFINED IN THE STRUCTURAL LEGEND. 2.UNLESS SPECIFICALLY INDICATED AS SLIP CRITICAL OR PRETENSIONED, ALL JOINTS SHALL BE DESIGNATED AS SNUG TIGHT. ROUTINE OBSERVATION TO VERIFY THE SPLINED ENDS ARE PROPERLY SEVERED DURING INSTALLATION IS REQUIRED FOR ALL BOLTS. 3.CANTILEVER BEAM SIZE MATCHES MAIN SPAN BEAM SIZE UNLESS NOTED OTHERWISE. 4.PLACE NON-SHRINK GROUT UNDER ALL COLUMN BASE PLATES BEFORE PLACING ANY ELEVATED CONCRETE LEVELS. 5.WHERE THE WORK OF OTHER TRADES REQUIRES CUTS OR OPENINGS TO BE MADE IN STRUCTURAL STEEL MEMBERS, APPROVAL SHALL BE OBTAINED FROM THE ENGINEER. SUCH OPENINGS SHALL BE MADE IN THE SHOP AND CLEARLY INDICATED ON THE SHOP DRAWING. 6.ALL HSS AND PIPE WITH OPEN ENDS SHALL BE CAPPED WITH A 1/4" THICK PLATE OF THE SAME CROSS SECTION WHICH COMPLETELY COVERS THE OPEN END, FULLY WELDED AND GROUND SMOOTH, UNLESS NOTED OTHERWISE. 7.ALL WELDERS MUST BE QUALIFIED IN THE PROCESS USED AND AWS CERTIFIED. 8.WELD LENGTHS CALLED FOR ON THE PLANS ARE THE NET EFFECTIVE LENGTH REQUIRED. WHERE FILLET WELD SYMBOL IS GIVEN WITHOUT INDICATION OF SIZE, USE MINIMUM SIZE WELDS AS SPECIFIED BY AISC OR 3/16", WHICH EVER IS GREATER. 9.ALL GROOVE WELDS INDICATED ON PLANS AND SECTIONS SHALL BE COMPLETE JOINT PENETRATION (CJP) WELDS UNLESS SPECIFICALLY INDICATED TO BE PARTIAL JOINT PENETRATION (PJP) WELDS. 10. ALL COMPLETE JOINT PENETRATION GROOVE WELDS AND FILLET WELDS AT BRACING CONNECTIONS SHALL HAVE A FILLER METAL WITH A MINIMUM NOTCH TOUGHNESS OF 20 FOOT-POUNDS AVERAGE AT MINUS 20 DEGREES FAHRENHEIT. STRUCTURAL STEEL ADHESIVE ANCHOR TEST SCHEDULE ANCHORS INSTALLED IN HARDROCK CONCRETE F'c = 2,000 psi MIN BOLTS OR THREADED RODS Fy = 36 ksi ANCHOR MIN TENSION TEST DIAMETER EMBEDMENT LOAD 3/8" 5"3,380 LB 1/2" 7"5,400 LB 5/8" 8"9,390 LB 3/4" 10"13,500 LB 7/8" 12"18,400 LB 1" 13"24,100 LB 1 1/4" 15"37,600 LB NOTE: ALLOWABLE LOADS EQUAL 1/2 TEST LOAD VALUE. TEST VALUES ONLY VALID WHEN MINIMUM SPACING AND EDGE DISTANCE IS MET. 19.THE FOLLOWING SPECIAL REQUIREMENTS SHALL APPLY TO BEAM TO COLUMN CONNECTIONS WITH WELDED BEAM FLANGES DESIGNATED AS A PART OF THE SEISMIC FORCE-RESISTING SYSTEM: A.NO WELD DAMS ARE ALLOWED. B.BEAM FLANGE TO COLUMN WELDS SHALL BE MADE BEFORE BOLTS ARE TENSIONED. C.WELDING SEQUENCE: BOTH FLANGES SHALL BE WELDED PRIOR TO ANY SUPPLEMENTAL WELDING TO THE SHEAR TAB. D.RUN-OFF TABS PER AWS D1.1 ARE REQUIRED FOR THE COMPLETE JOINT PENETRATION (CJP) FLANGE GROVE WELDS. ALL WELDS ARE TO BE STARTED AND COMPLETED ON THE RUN-OFF TABS AS MUCH AS PRACTICABLE. E.RUN-OFF TABS SHALL BE REMOVED AND THE ENDS GROUND SMOOTH (I.E. NO PITS OR GOUGES, SUITABLE FOR MAGNETIC PARTICLE TESTING). BACK-UP BARS, IF USED, SHALL BE REMOVED AT ALL BEAM BOTTOM FLANGES, BACK-GOUGED AND BACK-WELDED. BACK-UP BARS AT TOP FLANGES MAY REMAIN. RUN OFF TABS ARE ALSO REQUIRED TO BE REMOVED ON COLUMN SPLICES IN ACCORDANCE WITH AISC 341. WELD TABS SHALL BE REMOVED AND GROUND FLUSH TO THE BEAM FLANGE. F.THE WELD ROOT SHALL BE INSPECTED AND TESTED PER AWS REQUIREMENTS GIVEN IN CHAPTER 6. IF REJECTABLE INDICATIONS ARE FOUND, REMOVE BY BACK-GOUGING TO SOUND METAL. G.A FILLET WELD SHALL BE APPLIED TO REINFORCE THE JOINT. THE SIZE OF THE REINFORCING WELD SHALL BE EQUAL TO ONE QUARTER OF THE BEAM FLANGE THICKNESS (T), BUT NOT LESS THAN 1/4" NOR MORE THAN 3/8" PER NOTE J OF FIGURE 3.4 OF D1.1. H.ALL WELD TABS (RUNOFF TABS) ON ALL CJP WELDS OF SMRF COLUMNS SHALL BE REMOVED AND GROUND SMOOTH. I.FOR THE WELD OF THE BOTTOM BEAM FLANGE TO THE COLUMN FLANGE, FOLLOW STEPS 1. THROUGH 7 BELOW: a.THE ROOT PASS SHOULD NOT EXCEED A 1/4”IN LAYER THICKNESS. b.THE WELD SHALL BE INITIATED ON THE WELD TAB, WITH TRAVEL PROGRESSING TOWARD THE CENTER OF THE GIRDER FLANGE WIDTH. STOP WELD APPROXIMATELY 1” BEFORE THE BEAM WEB AND MOVE TO THE OTHER SIDE OF THE BEAM WEB TO RESTART WELD. DO NOT LEAVE WELD CRATER DIRECTLY IN THE CENTER OF THE BEAM FLANGE WIDTH. c.THE HALF LENGTH ROOT PASS SHALL BE THOROUGHLY CLEANED OF ALL SLAG. d.THE END OF THE HALF LENGTH ROOT PASS THAT IS NEAR THE CENTER OF THE BEAM FLANGE SHOULD BE VISUALLY INSPECTED TO ENSURE FUSION, SOUNDNESS, FREEDOM FROM SLAG INCLUSIONS AND EXCESSIVE POROSITY. THE RESULTING BEAD PROFILE SHOULD BE SUITABLE FOR OBTAINING FUSION BY THE SUBSEQUENT PASS TO BE INITIATED ON THE OPPOSITE SIDE OF THE GIRDER WEB. IF THE PROFILE IS NOT CONDUCIVE TO GOOD FUSION, THE START OF THE FIRST ROOT PASS SHOULD BE GROUND GOUGED, CHIPPED OR OTHERWISE PREPARED TO ENSURE ADEQUATE FUSION. e.THE SECOND HALF OF THE WELD JOINT SHALL HAVE THE ROOT PASS APPLIED BEFORE ANY OTHER WELD PASSES ARE PERFORMED. THE ARC SHOULD BE INITIATED AT THE END OF THE HALF LENGTH ROOT PASS THAT IS NEAR THE CENTER OF THE BEAM FLANGE, AND TRAVEL SHOULD PROGRESS TO THE OUTBOARD END OF THE JOINT, TERMINATING ON THE WELD TAB. f.EACH WELD LAYER SHALL BE COMPLETED ON BOTH SIDES OF THE JOINT BEFORE A NEW LAYER IS DEPOSITED. g.WELD TABS SHALL BE REMOVED AND GROUND FLUSH TO THE BEAM FLANGE. 20. INSPECTORS ARE TO BE DEPUTY INSPECTORS AND AWS QC-1 CERTIFIED. 21.ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIPPED GALVANIZED. STRUCTURAL STEEL (CONT'D)ADHESIVE ANCHORS AND DOWELS (CONT'D) 4.ADHESIVE ANCHORS SHALL BE INSTALLED AND TESTED IN ACCORDANCE WITH THE ADHESIVE ANCHOR TEST SCHEDULE AND AS FOLLOWS: A.25% OF THE FIRST 40 ANCHORS INSTALLED AND 10% OF ALL ANCHORS THEREAFTER. B.FOR OVERHEAD AND HORIZONTAL APPLICATIONS TEST 100% OF ALL ANCHORS. C.IF ANY FAILURES OCCUR, THE PREVIOUS 10 ANCHORS INSTALLED SHALL BE TESTED AS WELL AS THE NEXT 5 ANCHORS INSTALLED. D.ANCHORS SHALL BE ALLOWED TO CURE 48 HRS PRIOR TO TESTING. E.TENSION TEST SHALL BE IN ACCORDANCE WITH ASTM E1512. 1.HEADED STUDS AND DEFORMED BAR ANCHORS SHALL BE ELECTRIC-ARC STUD WELDED PER MANUFACTURERS RECOMMENDATIONS AND THE AWS CODE. FILLET WELDING SHALL NOT BE ALLOWED WITHOUT APPROVAL OF THE STRUCTURAL ENGINEER. WELDMENT SHALL BE IN SUCH A MANNER AS TO PROVIDE COMPLETE FUSION BETWEEN THE END OF THE STUD AND THE PLATE. THERE SHOULD NO POROSITY OR EVIDENCE OF LACK OF FUSION BETWEEN THE WELDED END OF THE STUD AND THE PLATE. THE STUD WILL DECREASE IN LENGTH DURING WELDING APPROXIMATELY 1/8”FOR 5/8”DIAMETER STUDS AND SMALLER, 3/16”FOR LARGER THAN 5/8”DIAMETER. HEADED STUDS AND DEFORMED BAR ANCHORS HEADED STUDS AND DEFORMED BAR ANCHORS (CONT'D) 2.HEADED STUDS SHALL BE TYPE B PER AWS CODE WITH MINIMUM ULTIMATE STRENGTH OF 65 KSI (450 MPa). NELSON GRANULAR FLUX FILLED OR APPROVED EQUAL. STUDS SHALL BE MANUFACTURED WITH COLD DRAWN BAR STOCK CONFORMING TO ASTM A108. 3.DEFORMED BAR ANCHORS SHALL COMPLY WITH ASTM A970 WITH MINIMUM YIELD STRENGTH OF 70 KSI (485 MPa). 4.DEFORMED BAR ANCHOR LENGTHS SHALL BE AS FOLLOWS, UNLESS NOTED OTHERWISE: BAR DIAMETER EMBEDMENT LENGTH 3/8" 24" 1/2" 24" 5/8" 30" SEISMIC BRACING OF NON-STRUCTURAL SYSTEMS 1.BRACING AND SUPPORT OF ALL CONDUITS, DUCTS, FIRE SPRINKLERS, PIPES, AND SYSTEMS SHALL MEET THE CURRENT BUILDING CODE. THE DESIGN OF THE SUPPORT AND BRACING SYSTEMS IS THE RESPONSIBILITY OF THE CONTRACTOR WITH THE CONTRACTOR USING ANY PRE-APPROVED SYSTEM. 2.PRE-APPROVED SYSTEMS SUCH AS MASON, TOLCO, UNISTRUT, OR ISAT MAY BE USED. 3.FIRE SPRINKLERS SHALL MEET THE CURRENT VERSION OF NFPA 13. BRACES SHALL BE LOCATED WITHIN 6”OF THE HANGER AND ROD STIFFENERS SHALL BE ADDED AT BRACE LOCATIONS WHEN THE LENGTH OF THE ROD EXCEEDS 50 TIMES ITS DIAMETER. 4.THE CONTRACTOR IS REQUIRED TO PROVIDE THE ARCHITECT WITH SHOP DRAWINGS AND CALCULATIONS SHOWING ALL BRACING AND SUPPORT LOCATIONS AND DETAILS OF CONNECTION FOR ALL SYSTEMS INCLUDING SMACNA, FIRE SPRINKLERS, AND OTHER PRE-APPROVED SYSTEMS. THE SPECIFIC DETAIL FOR EACH TYPE OF CONNECTION MUST BE REFERENCED ON THE SHOP DRAWING PLANS. SUPPLYING A BOOK OF DETAILS WITHOUT REFERENCING THE PROPER DETAIL TO A SPECIFIC LOCATION ON THE PLANS IS NOT ACCEPTABLE. THIS SUBMITTAL SHALL BE REVIEWED BY THE STRUCTURAL ENGINEER. 5.WHERE PRE-APPROVED SYSTEMS DO NOT ADDRESS THE GIVEN CONDITION, THE CONTRACTOR IS RESPONSIBLE FOR AN INDEPENDENTLY ENGINEERED SYSTEM. THIS SYSTEM SHALL BE DESIGNED BY A LICENSED PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF CONSTRUCTION WITH CALCULATIONS AND DETAILS PROVIDED FOR REVIEW BY THE STRUCTURAL ENGINEER. DEFERRED STRUCTURAL SUBMITTALS 1.SOME STRUCTURAL SYSTEMS ARE DEFINED AS VENDOR COMPONENTS PER THE STRUCTURAL DOCUMENTS. THESE ELEMENTS OF THE DESIGN ARE DEFERRED SUBMITTAL COMPONENTS AND HAVE NOT BEEN PERMITTED UNDER THE BASE BUILDING APPLICATION. THE CONTRACTOR WILL BE REQUIRED TO SUBMIT THE STAMPED COMPONENT SYSTEM DOCUMENTS TO THE BUILDING OFFICIAL FOR APPROVAL. 2.DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT, WHO SHALL REVIEW THEM FOR GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. THE CONTRACTOR SHALL SUBMIT THESE REVIEWED DEFERRED SUBMITTAL DOCUMENTS TO THE BUILDING OFFICIAL. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. 3.THE FOLLOWING LIST INCLUDES THE ITEMS THAT ARE DEFINED AS DEFERRED STRUCTURAL SUBMITTAL COMPONENTS. REFER TO THE OTHER DISCIPLINES FOR ADDITIONAL DEFERRED SUBMITTAL COMPONENTS. EXTERIOR CLADDING FENESTRATION / CLERESTORY DESIGN METAL STUD SYSTEM METAL STAIRS AND LANDINGS FUTURE EXPANSION 1.THE STRUCTURES AND FOUNDATIONS IN THIS PROJECT HAVE NOT BEEN DESIGNED FOR FUTURE EXPANSION. R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 9 : 1 8 A M BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SZN002 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL GENERAL STRUCTURAL NOTESLPDDJPAEISSUED FOR BID12/10/2024 E XPANSAI OIP CSS N H R A P ENNPCRPN I H D SU C 11AOY1Y.L T RPNTRE S A L OR I A E F R PN S A E I O ALE C(P N P R N NE G F N GFR 15/Nov/2024 0346 RTA/CN 0205-24 STRUCTURAL LEGEND F-XX (XXX'-X") TOP OF FOOTING ELEVATION FOOTING MARK 1i (XX) c=X" CAMBER NO. OF STUDS FRAMING MEMBER NOTE DIRECTION OF SPAN FRAMING MEMBER MOMENT CONNECTION COLUMN FRAMING MEMBER BEAM SPLICE LOCATION FRAMING MEMBER FOOTING TAG: FRAMING TAG: SPAN SYMBOL: MOMENT FRAME: BEAM SPLICE: FRAMING MEMBER MOMENT CONNECTION COLUMN MOMENT CONNECTION: WEB PENETRATION MARK WEB PENETRATION LOCATION FRAMING MEMBER BEAM WEB PENETRATION: X N"DIMENSION FROM TOP OF STEEL TO CENTER OF WEB PENETRATION TOP OF TOP OF CONCRETE TOP OF FOOTING TOP OF SLAB, TOP OF STEEL, TOP OF WALL TYPICAL UNLESS NOTED OTHERWISE VERTICAL WITH WITHOUT WIND LOAD WELDED WEIGHT WELDED WIRE FABRIC TO TOC TOF TOS TOW TYP UNO VERT W/ W/O W WLD WT WWF RADIUS ROOF DRAIN RIGHT END REFER TO REINFORCING REQUIRED SCHEDULE STRUCTURAL ENGINEER OF RECORD SQUARE FOOT SEPARATION SIMILAR SHEET METAL SCREW SLAB ON GRADE SLAB ON METAL DECK SPACING SPECIFICATION SQUARE STAINLESS STEEL STANDARD STIFFENER STRUCTURAL SYMBOL TOP AND BOTTOM TEMPORARY, TEMPERATURE R RD RE REF REINF REQD SCHED SEOR SF SPN SIM SMS SOG SOMD SPA SPEC SQ SST STD STIF STRUCT SYM T&B TEMP NOMINAL NEAR SIDE NOT TO SCALE NORMAL WEIGHT ON CENTER OUTSIDE DIAMETER OUTSIDE FACE OPENING OPPOSITE OUTSTANDING LEG POWER ACTUATED FASTENER PARTIAL JOINT PENETRATION PLATE PLUMBING POUNDS PER LINEAR FOOT PAIR PREFABRICATED PARALLEL POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PAVEMENT NOM NS NTS NWT OC OD OF OPNG OPP OSL PAF PJP PL PLBG PLF PR PREFAB PRL PSF PSI PVMT ID IF IN IF INSTR INT JT K KSF L LE LF LLH LLV LOC LONG LWT MATL MAX MECH MEP MFR MIN MISC MO MTL INSIDE DIAMETER INSIDE FACE INCH INSIDE FACE INSTRUMENTATION INTERIOR, INTERSECTION JOINT KIPS KIPS PER SQUARE FOOT LIVE LOAD LEFT END LINEAR FOOT LONG LEG HORIZONTAL LONG LEG VERTICAL LOCATION LONGITUDINAL LIGHTWEIGHT MATERIAL MAXIMUM MECHANICAL MECHANICAL, ELECTRICAL, PLUMBING MANUFACTURER MINIMUM MISCELLANEOUS MASONRY OPENING METAL FD FDN FLR FN FS FT FTG FUT FV GA GALV GC GR GRTG HK HORIZ HSB HS HSS HT FLOOR DRAIN FOUNDATION FLOOR FIELD NAILING FAR SIDE FEET, FOOT FOOTING FUTURE FIELD VERIFY GAGE, GAUGE GALVANIZED GENERAL CONTRACTOR GRADE GRATING HOOK HORIZONTAL HIGH STRENGTH BOLT HEADED STUD, HIGH STRENGTH HOLLOW STRUCTURAL SHAPE HEIGHT CLR CMU COL CONC CONN CONST CONT CONTR C TO C DBA DBL DET DIA DIAG DIM DL DO DWG DWL EA EE EF EFF EJ ELEV ELEC EMB EOS EQ ES EW EXP EXIST EXT CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CONTRACTOR CENTER TO CENTER DEFORMED BAR ANCHOR DOUBLE DETAIL DIAMETER DIAGONAL, DIAGRAM DIMENSION DEAD LOAD DITTO DRAWING DOWEL EACH EACH END EACH FACE EFFECTIVE EXPANSION JOINT ELEVATION ELECTRICAL EMBEDDED, EMBEDMENT EDGE OF SLAB EQUAL EACH SIDE, EQUAL SPACE, EACH WAY EXPANSION EXISTING EXTERIOR AB ADDL AFF AFG AGGR ARCH BL BM BOT BP BRG CANT CIP CJ CL ANCHOR BOLT ADDITIONAL ABOVE FINISH FLOOR ABOVE FINISH GRADE AGGREGATE ARCHITECTURAL BASE LINE BENCHMARK, BEAM BOTTOM BASE PLATE BEARING CANTILEVER CAST-IN-PLACE CONSTRUCTION OR CONTROL JOINT CENTERLINE, CLASS, CLOSE BKT BRACKET BN BOUNDARY NAILING BOF BOTTOM OF FOOTING BSMT BASEMENT BTWN BETWEEN CG CENTER OF GRAVITY CJP COMPLETE JOINT PENETRATION SECTIONSECT ABBREVIATIONS SUPERIMPOSED DEADLOADSDL BF BRACKET CTR CENTER MF MOMENT FRAME PERIMETERPRMT STEELSTL THICKNESSTHK BRACED FRAME R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 9 : 2 0 A M BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SZN003 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL GENERAL STRUCTURAL NOTESLPDDJPAE ISSUED FOR BID12/10/2024 GENERAL NOTES: 1.REFER TO GEN-GZN006 & GEN-GZN007 FOR ADDITIONAL SYMBOLS AND LEGEND. S TRUCAUL LREGAA C N E D U E R SCCRGDRC LENBAV G FF"PKFK-I O T OP TF C N R ET I N F G T O P A U S L UI S GPR C R D C CS S G P SGT 15/Nov/2024 0347 RTA/CN 0205-24 SLAB CLADDING DEAD LOAD PER LOAD MAPS, SEE NOTE 1.MAX HORIZONTAL CLADDING DEAD LOAD 500 LBS, SEE NOTE 2. MOMENT DUE TO CLADDING DEAD LOAD, SEE NOTE 3. BEAM AS OCCURS, SEE NOTE 4. NOTES: 1.STRUCTURE IS DESIGNED FOR THE EQUIVALENT UNIFORM LOAD CORRESPONDING TO THE ANTICIPATED WEIGHT OF THE CLADDING SYSTEM AS NOTED IN THE LOAD MAPS. 2.ANY HORIZONTAL CLADDING ATTACHMENT TO PRIMARY STRUCTURE SHALL NOT EXCEED THE NOTE MAGNITUDE. SPACING BETWEEN ATTACHMENTS SHALL BE NO GREATER THAN 2'-0". 3.THERE SHALL BE NO MOMENT IMPOSED TO THE PRIMARY STRUCTURE DUE TO THE CLADDING DEAD LOAD. 4.CLADDING CONNECTIONS SHALL NOT APPLY LATERAL OR TORSIONAL LOADS TO THE PERIMETER BEAMS OR COLUMNS. 5.CLADDING ATTACHMENTS WILL APPLY CONCENTRATED LOADS TO THE PRIMARY STRUCTURE. CONTRACTOR SHALL SUBMIT TYPICAL CLADDING ATTACHMENT DETAILS FOR REVIEW AND COMMENT PRIOR TO PREPARATION OF A DETAILED CLADDING SUBMITTAL. 1.B 1.E 1.1 1.7 1.8 1.15 2.1 2.J 2.11 2.A A1 A1 B2 A2 B2 D1 C1 50 7'-6" 15 7'-6" 50 7'-6" D1 CABINET 0.70k TVM 0.41k TVM 0.41k CABINET 0.70k CABINET 0.70k C1SWITCHBOARD 3.4k TRANSFORMER 0.4k TRANSFORMER 0.7k TRANSFORMER 1.2k UPS 1.2k UPS 0.5k A1 1.B 1.E 1.1 1.4 1.5 1.7 1.8 1.15 2.1 2.J 2.11 2.A E4 10 3'-9" E4 10 3'-9" 10 3'-9" E4 E5 E5 E515 7'-6" 50 7'-6" 50 7'-6" C1 HEAT PUMP 0.1k HEAT PUMP 0.3k HEAT PUMP 0.2k E4E4 LIVE LOAD SCHEDULE MARK OCCUPANCY OR USE LIVE LOAD (PSF) A LOBBY/CORRIDOR 100 SUPER IMPOSED DEAD LOAD SCHEDULE MARK DESCRIPTION TOTAL (PSF) 1 PLATFORM 5 CEILING & MEPF (PSF) - FLOOR FINISH (PSF) 5 EXTRA LOAD (PSF) - NOTES - NOTES: 1. INDICATES LIVE LOAD AND SUPERIMPOSED DEAD LOAD MARK, RESPECTIVELY. 2. INDICATES CLADDING DEAD LOAD IN POUNDS PER SQUARE FOOT AND HEIGHT OF CLADDING ASSUMED, RESPECTIVELY. 3. LIVE LOADS MARKED (RED) ARE REDUCIBLE IN ACCORDANCE WITH THE GOVERNING BUILDING CODE. 4. SUPERIMPOSED DEAD LOADS ARE IN ADDITION TO THE SELF-WEIGHT OF THE STRUCTURE. 5. INDICATES CONCRETE PAD OCCURANCE. REFER TO TYPICAL CONCRETE PAD DETAIL FOR ADDITIONAL INFORMATION. ##' B OFFICE 65 D MECH/ELEC/STORAGE 250* E ROOF 20 (RED) 2 CORE FACILITIES 15 -15 -- 3 LIGHT ROOF 15 5 10 -- 4 HEAVY ROOF 25 15 10 -- X# C LIGHT MECH/ELEC 125* *OR EQUIPMENT LOADS COMPONANT AND CLADDING WIND PRESSURES, PSF (POSITIVE PRESSURE, NEGATIVE SUCTION) ZONE 1 +16 -20 MAX PRESSURE MAX SUCTION ZONE 2 +16 -23 ZONE 3 +16 -30 ZONE 4 +16 -18 ZONE 5 +16 -22 3 3 3 3 2 2 2 1 a a a a a a a a 5 4 5 5 4 5 NOTES: 1."a" REFERS TO 10% OF THE LEAST HORIZONTAL DIMENSION OF 40% OF THE STRUCTURE HEIGHT "h" WHICH EVER IS SMALLER. "a" MAY NOT BE LESS THAN EITHER 4% OF THE L EAST HORIZONTAL DIMENSION OR 3'-0". 2.PRESSURES GIVEN ARE FOR AN EFFECTIVE WIND AREA LESS THAN 10 SQUARE FEET. LOAD REDUCTION FOR GREATER EFFECTIVE WIND AREAS IS ALLOWED BY CODE. 3.WIND PRESSURES ARE ULTIMATE WIND PRESSURES. MULTIPLY VALUES BY 0.6 TO OBTAIN ALLOWABLE WIND PRESSURES. 4.CLADDING AT ANY SOFFIT SHALL BE DESIGNED FOR A NET 30 PSF WIND LOAD. COMPONENT/CLADDING WIND ZONES: ROOFS COMPONENT/CLADDING WIND ZONES: WALLS R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 1 1 / 2 0 2 5 3 : 2 1 : 5 8 P M BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SZP001 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL LOAD MAPS, DIAGRAMS, AND SCHEDULESLPDDJPAE LPD AJF AE 12/10/2024 348ISSUED FOR BID SCALE: NTS CLADDING DEAD LOAD DIAGRAM 3 - SCALE: 1" = 50'-0" LOAD MAP - GROUND FLOOR SCALE: 1" = 50'-0" LOAD MAP - ROOF SCALE: NTS LOAD MAP SCHEDULES AND NOTES 1 -SCALE: NTS WIND PRESSURE DIAGRAM 2 - 1 1 1 1 1 06/13/2025 ADDENDUM #1 1 1.B 1.E 1.1 1.4 1.5 1.7 1.8 1.151 BT120-SFP212 1 BT120-SGP312 1 BT120-SFP213 1 BT120-SGP313 1 BT120-SFP214 1 BT120-SGP314 2.1 2.J 2.11 2.A 1 BT120-SFP241 1.16 1.17 1 BT120-SFP215 1 BT120-SFP221 1 BT120-SGP521 1 BT120-SGP421 1 BT120-SGD161 1 BT120-SGP321 5.25.1 5.B 5.A 1 BT120-SGD163 2 BT120-SGD163 C BT120-SGD161 REFERENCE DRAWINGS: BT120-SZN__GENERAL NOTES BT120-SZP__LOAD MAPS BT120-SFP__FOUNDATION PLANS BT120-SGP__PLANS BT120-SGE__ELEVATIONS BT120-SGY__TYPICAL DETAILS AND SCHEDULES BT120-SGD__SECTIONS AND DETAILS REFERENCE DRAWINGS: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 7 : 4 9 A M BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SFP001 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL OVERALL SITE PLANLPDDJPAE LPD AJF AE 1" = 30' 12/10/2024 349ISSUED FOR BID SCALE IN FEET 15 3030 600 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 1 1 06/13/2025 ADDENDUM #1 1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 1.B 1.C 1.1 1.2 1.3 1.4 24' - 0"24' - 0"24' - 0" 14 ' - 0 " 14 ' - 0 " MA T C H L I N E : SE E D W G B T 1 2 0 -SF P 2 1 3HSS10X10X3/4A BT120-SGE111 TYPTYPPC2PC2PC2 PC2 1 BT120-SGD162 2 BT120-SGD162 SIM GB12x12 GB12x12 GB12x12 TVM PYLON ADA TACTILE STRIP RECESS CONC CURB PER CIVIL, TYP TACTILE STRIP RECESS, TYP D BT120-SGD113 E BT120-SGD113 TYP SL SL SL SL SOG PLATFORM, SLOPES PER CIVIL RAMP PER CIVIL, TYP 1.A 14 ' - 6 " 3" 8" THICKENED SOG, 3'-0" X 3'-0", CTR ON POST NOTES: 1.LEVEL 01 -CANOPY SECTOR A REFERENCE ELEVATION IS 22'-4". REFER TO CIVIL DRAWINGS FOR ELEVATION AND SLOPE OF SLAB ON GRADE. 2.SLAB ON GRADE IS 6-INCHES THICK MINIMUM. REFER TO CIVIL AND ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. REINFORCE PER TYPICAL DETAILS. SLAB ON GRADE SHALL BE PLACED ATOP COMPACTED STRUCTURAL FILL IN ACCORDANCE WITH GEOTECHNICAL REPORT. 3.( ) INDICATES TOP OF PILE CAP ELEVATION. ALL PILE CAPS AND PILES SHALL BEAR ON SUBGRADE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. TOP OF PILE CAP ELEVATION IS AT REFERENCE ELEVATION UNLESS NOTED OTHERWISE. 4."PC#" INDICATES PILE CAP MARK. SEE TYPICAL PILE AND PILE CAP DETAILS AND SCHEDULES FOR SIZE, REINFORCING, AND ADDITIONAL INFORMATION. 5."GB#" INDICATES GRADE BEAM MARK. SEE TYPICAL GRADE BEAM DETAILS AND SCHEDULES FOR SIZE, REINFORCING, AND ADDITIONAL INFORMATION. 6.COLUMNS SHOWN IN THE VIEW ARE PART OF THE MAIN LATERAL FORCE RESISTING SYSTEM. 7.REFERENCE ALL CONSTRUCTION DOCUMENTS FOR SIZE, EXTENT, AND LOCATION OF CONCRETE CURBS, HOUSEKEEPING PADS, CMU WALLS, PLANTER WALLS, BOLLARDS, EDGE ANGLES, AND SLAB PENETRATIONS. REINFORCE PER TYPICAL DETAILS. GENERAL NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 2 : 4 5 : 0 7 P M BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SFP212 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL FOUNDATION PLAN CANOPY - SECTOR A LPD DJP AE LPD AJF AE 1/8" = 1'-0" 12/10/2024 350ISSUED FOR BID SCALE IN FEET 4 0 88 16 SCALE: 1/8" = 1'-0" FOUNDATION PLAN - CANOPY - SECTOR A 1 BT120-SGP100 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 1.B 1.C 1.5 1.6 1.7 MA T C H L I N E : SE E D W G B T 1 2 0 -SF P 2 1 2 M A T C H L I N E : S E E D W G B T 1 2 0 - S F P 2 1 4 24' - 0"24' - 0"HSS10X10X3/4TYP14 ' - 0 " 14 ' - 0 " A BT120-SGE111TYPPC2PC2PC2 2 BT120-SGD162 2 BT120-SGD162 SIM GB12x12 GB12x12 PYLON ADA TACTILE STRIP RECESS ADA TACTILE STRIP RECESS TACTILE STRIP RECESS, TYP CONC CURB PER CIVIL, TYP D BT120-SGD113 E BT120-SGD113 TYP TYP SL SL S L SOG PLATFORM, SLOPES PER CIVIL 1.A RAMP PER CIVIL, TYP 6" 3" 8" THICKENED SOG, 3'-0" X 3'-0", CTR ON POST 14 ' - 6 " 3" 8" THICKENED SOG, 3'-0" X 3'-0", CTR ON POST NOTES: 1.LEVEL 01 -CANOPY SECTOR B REFERENCE ELEVATION IS 25'-1". REFER TO CIVIL DRAWINGS FOR ELEVATION AND SLOPE OF SLAB ON GRADE. 2.SLAB ON GRADE IS 6-INCHES THICK MINIMUM. REFER TO CIVIL AND ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. REINFORCE PER TYPICAL DETAILS. SLAB ON GRADE SHALL BE PLACED ATOP COMPACTED STRUCTURAL FILL IN ACCORDANCE WITH GEOTECHNICAL REPORT. 3.( ) INDICATES TOP OF PILE CAP ELEVATION. ALL PILE CAPS AND PILES SHALL BEAR ON SUBGRADE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. TOP OF PILE CAP ELEVATION IS AT REFERENCE ELEVATION UNLESS NOTED OTHERWISE. 4."PC#" INDICATES PILE CAP MARK. SEE TYPICAL PILE AND PILE CAP DETAILS AND SCHEDULES FOR SIZE, REINFORCING, AND ADDITIONAL INFORMATION. 5."GB#" INDICATES GRADE BEAM MARK. SEE TYPICAL GRADE BEAM DETAILS AND SCHEDULES FOR SIZE, REINFORCING, AND ADDITIONAL INFORMATION 6.COLUMNS SHOWN IN THE VIEW ARE PART OF THE MAIN LATERAL FORCE RESISTING SYSTEM. 7.REFERENCE ALL CONSTRUCTION DOCUMENTS FOR SIZE, EXTENT, AND LOCATION OF CONCRETE CURBS, HOUSEKEEPING PADS, CMU WALLS, PLANTER WALLS, BOLLARDS, EDGE ANGLES, AND SLAB PENETRATIONS. REINFORCE PER TYPICAL DETAILS. GENERAL NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 7 : 5 1 A M BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SFP213 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL FOUNDATION PLAN CANOPY - SECTOR B LPD DJP AE LPD AJF AE 1/8" = 1'-0" 12/10/2024 351ISSUED FOR BID SCALE IN FEET 4 0 88 16 SCALE: 1/8" = 1'-0" FOUNDATION PLAN - CANOPY - SECTOR B 1 BT120-SGP100 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 1.E 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.15 24' - 0"24' - 0"24' - 0"24' - 0"24' - 0"24' - 0"24' - 0" MATCH LINE: SEE DWG BT120-SFP213HSS10X10X3/4TYPA BT120-SGE111TYP2 BT120-SGD162 1 BT120-SGD162 GB12x12 GB12x12 GB12x12 GB12x12 GB12x12 GB12x12 GB12x12 2 BT120-SGD162 SIM 2 BT120-SGD162 PC2 PC2 PC2 PC2 PC2 PC2 PC2 PC2 ADA TACTILE STRIP RECESS MA T C H L I N E : SE E D W G B T 1 2 0 -SF P 2 1 5 ADA TACTILE STRIP RECESS ADA TACTILE STRIP RECESS E BT120-SGD113 TYP D BT120-SGD113 TYP TACTILE STRIP RECESS, TYP CONC CURB PER CIVIL, TYP SL RAMP PER CIVIL SOG PLATFORM, SLOPES PER CIVIL 1.F 1.D 14 ' - 0 " 14 ' - 0 " 6" 3" 14 ' - 6 " 7' - 9"8" THICKENED SOG, 3'-0" X 3'-0", CTR ON POST 8" THICKENED SOG, 3'-0" X 3'-0", CTR ON POST 8" THICKENED SOG, 3'-0" X 3'-0", CTR ON POST 7' - 9" 14 ' - 6 " NOTES: 1.LEVEL 01 -CANOPY SECTOR C REFERENCE ELEVATION IS 26'-4". REFER TO CIVIL DRAWINGS FOR ELEVATION AND SLOPE OF SLAB ON GRADE. 2.SLAB ON GRADE IS 6-INCHES THICK MINIMUM. REFER TO CIVIL AND ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. REINFORCE PER TYPICAL DETAILS. SLAB ON GRADE SHALL BE PLACED ATOP COMPACTED STRUCTURAL FILL IN ACCORDANCE WITH GEOTECHNICAL REPORT. 3.( ) INDICATES TOP OF PILE CAP ELEVATION. ALL PILE CAPS AND PILES SHALL BEAR ON SUBGRADE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. TOP OF PILE CAP ELEVATION IS AT REFERENCE ELEVATION UNLESS NOTED OTHERWISE. 4."PC#" INDICATES PILE CAP MARK. SEE TYPICAL PILE AND PILE CAP DETAILS AND SCHEDULES FOR SIZE, REINFORCING, AND ADDITIONAL INFORMATION. 5."GB#" INDICATES GRADE BEAM MARK. SEE TYPICAL GRADE BEAM DETAILS AND SCHEDULES FOR SIZE, REINFORCING, AND ADDITIONAL INFORMATION 6.COLUMNS SHOWN IN THE VIEW ARE PART OF THE MAIN LATERAL FORCE RESISTING SYSTEM. 7.REFERENCE ALL CONSTRUCTION DOCUMENTS FOR SIZE, EXTENT, AND LOCATION OF CONCRETE CURBS, HOUSEKEEPING PADS, CMU WALLS, PLANTER WALLS, BOLLARDS, EDGE ANGLES, AND SLAB PENETRATIONS. REINFORCE PER TYPICAL DETAILS. GENERAL NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 7 : 5 2 A M BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SFP214 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL FOUNDATION PLAN CANOPY - SECTOR C LPD DJP AE LPD AJF AE 1/8" = 1'-0" 12/10/2024 352ISSUED FOR BID SCALE IN FEET 4 0 88 16 SCALE: 1/8" = 1'-0" FOUNDATION PLAN - CANOPY - SECTOR C 1 BT120-SGP100 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 1.E 1.15 1.16 1.17 63' - 8"16' - 8" MA T C H L I N E : SE E D W G B T 1 2 0 -SF P 2 1 4 ADA TACTILE STRIP RECESS E BT120-SGD113 TYPD BT120-SGD113 TYP TACTILE STRIP RECESS, TYP CONC CURB PER CIVIL, TYP ADA TACTILE STRIP RECESS SL SLAB ON GRADE, SLOPES PER CIVIL RAMP PER CIVIL 1 BT120-SGD163 2 BT120-SGD163 1.F 1.D 14 ' - 0 " 14 ' - 0 " 8" THICKENED SOG, 4'-0" X 4'-0", CTR ON POST 12' - 0" 23' - 5" 14 ' - 6 " 8" THICKENED SOG, 3'-0" X 3'-0", CTR ON POST 36' - 0"54' - 0" 8" THICKENED SOG, 4'-0" X 4'-0", CTR ON POST 8" THICKENED SOG, 3'-0" X 3'-0", CTR ON POST 1" 14 ' - 6 " 8" THICKENED SOG, 3'-0" X 3'-0", CTR ON POST KCM SHELTER NOTES: 1.LEVEL 01 -CANOPY SECTOR D REFERENCE ELEVATION IS 27'-8". REFER TO CIVIL DRAWINGS FOR ELEVATION AND SLOPE OF SLAB ON GRADE. 2.SLAB ON GRADE IS 6-INCHES THICK MINIMUM. REFER TO CIVIL AND ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. REINFORCE PER TYPICAL DETAILS. SLAB ON GRADE SHALL BE PLACED ATOP COMPACTED STRUCTURAL FILL IN ACCORDANCE WITH GEOTECHNICAL REPORT. 3.REFERENCE ALL CONSTRUCTION DOCUMENTS FOR SIZE, EXTENT, AND LOCATION OF CONCRETE CURBS, HOUSEKEEPING PADS, CMU WALLS, PLANTER WALLS, BOLLARDS, EDGE ANGLES, AND SLAB PENETRATIONS. REINFORCE PER TYPICAL DETAILS. GENERAL NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 7 : 5 3 A M BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SFP215 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL FOUNDATION PLAN CANOPY - SECTOR D LPD DJP AE LPD AJF AE 1/8" = 1'-0" 12/10/2024 353ISSUED FOR BID SCALE: 1/8" = 1'-0"BT120-SFP001 FOUNDATION PLAN - CANOPY - SECTOR D 1 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE IN FEET 4 0 88 16 1 06/13/2025 ADDENDUM #1 1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 2.F 2.B 2.72.62.52.42.32.1 2.J 2.D 2.E 2.E 2.112.102.92.8 2.A 2.A 8' - 1"6' - 0"21' - 4"24' - 9"17' - 3"17' - 4"27' - 9"8' - 11"14' - 1"1' - 4" 2' - 0 " 10 ' - 9 " 2' - 8 " 2.C 2.2 4' - 0 " 11 ' - 5 " 6' - 0 " B F -2 .J 2.G 2.H 15 ' - 5 " 10 ' - 0 " 12 ' - 0 " 12 ' - 0 " B F-2.2 B F-2.2 B F-2.2 B F-2.2 B F -2.E B F-2.4 B F-2.4 B F -2.A B F -2.7 B F-2.7 B F -2.B M F -2.9 M F-2.9 M F -2.1 1 M F -2.1 1 H S S 6 X 6 X 1/4 T Y P , U N O PC1 TYP, UNO 1' - 3 1/2" TYP, UNO 1' - 3 1/2" REINFORCE SOG W/ #6 @ 12" OC BOT EW 2' - 3" 3' - 3" T1 T1 T1 T1 T1 T3 T1 T3 T1 T3 T1 T1 T3 T5 B1 T3 T3 T4T7 T2 T2T2 T1 T3 T3 T1 T1 T5 T1 T1 T1 T1 T8 T3 B1 B1 T1 T5 T3 T1 T1 T10 T1 T10 T9 T9 T9 T9 TYP, UNO 11 1/2"TYP, UNO 11 1/2" 1' - 3 1/2" REF 1' - 3 1/2" REF T3 T3 TYP, UNO 4' - 6" TYP, UNO 4' - 6" TYP 3' - 6 1/2" 5' - 6 1/2" 7' - 8 1/2" NOTES: 1.LEVEL 01 -CORE FACILITY REFERENCE ELEVATION IS 28'-2". TOP OF SLAB IS AT REFERENCE LEVEL. 2.SLAB ON GRADE IS 10-INCHES THICK. REINFORCE AS INDICATED ON PLAN. SLAB ON GRADE SHALL BE PLACED ATOP COMPACTED STRUCTURAL FILL IN ACCORDANCE WITH GEOTECHNICAL REPORT. 3.( ) INDICATES TOP OF PILE CAP ELEVATION. ALL PILE CAPS AND PILES SHALL BEAR ON SUBGRADE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. TOP OF PILE CAP ELEVATION IS AT REFERENCE ELEVATION UNLESS NOTED OTHERWISE. 4."PC#" INDICATES PILE CAP MARK. SEE TYPICAL PILE AND PILE CAP DETAILS AND SCHEDULES FOR SIZE, REINFORCING, AND ADDITIONAL INFORMATION. 5.SEE FRAMING ELEVATIONS FOR INFORMATION ON MAIN LATERAL FORCE-RESISTING SYSTEM. 6.REFERENCE ALL CONSTRUCTION DOCUMENTS FOR SIZE, EXTENT, AND LOCATION OF CONC CURBS, HOUSEKEEPING PADS, CMU WALLS, PLANTER WALLS, BOLLARDS, EDGE ANGLES, AND SLAB PENETRATIONS. REINFORCE PER TYP DETAILS. GENERAL NOTES: TOP BAR REINFORCING SCHEDULE MARK DETAILS NOTE T1 T2 (5) #5 @ 12" OC X 9'-2" W/ STD HOOK AT BOTH ENDS T3 T4 T5 T6 T7 T8 W/ STD HOOK (5) #5 @ 12" OC X 15'-0" (5) #5 @ 12" OC X 10'-0"- (5) #5 @ 12" OC X 12'-4"W/ STD HOOK AT BOTH ENDS (6) #5 @ 12" OC X 10'-0"- (7) #5 @ 12" OC X 15'-0"W/ STD HOOK AT BOTH ENDS - W/ STD HOOK (20) #5 @ 6" OC X 40'-0" (10) #5 @ 12" OC X 19'-2" BOTTOM BAR REINFORCING SCHEDULE MARK DETAILS NOTE B1 (3) #5 @ 12" OC X 4'-6"W/ STD HOOK AT BOTH ENDS T9 T10 W/ STD HOOK (7) #5 @ 12" OC X 14'-2" (5) #5 @ 12" OC X 14'-2" W/ STD HOOK R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-S-v2020.rvt 6/2/2025 11:27:54 AM BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SFP221 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL OVERALL FOUNDATION PLAN CORE FACILITYLPDDJP AE LPD AJF AE 3/16" = 1'-0" 12/10/2024 354ISSUED FOR BID SCALE: 3/16" = 1'-0"BT120-SFP001 CORE FACILITY OVERALL FOUNDATION PLAN 1 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE IN FEET 4 0 88 16 1 06/13/2025 ADDENDUM #1 1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 3.A 3.B 3.3 3.43.2 97' - 0"6' - 0"97' - 0" 7' - 7 " C BT120-SGE131 D BT120-SGE131TYP, UNOHSS6X6X3/8PC8 PC2A PC2A TYP (2) PLC TYP (4) PLC 3.1 (25'-6")(26'-0") 6" CONC WALL AROUND PILASTERS W/ #4 @ 12" EW, TYP 6" CONC WALL W/ #4 @ 12" EW 6" CONC WALL W/ #4 @ 12" EW - 1TYP NOTES: 1.LEVEL 01 -GANTRY REFERENCE ELEVATION IS 27'-0". 2.RIGID PAVEMENT OVER PILE CAPS IS PER CIVIL AND IS NOT SHOWN. RIGID PAVEMENT SHALL BE PLACED ATOP COMPACTED STRUCTURAL FILL IN ACCORDANCE WITH GEOTECHNICAL REPORT. 3.( ) INDICATES TOP OF PILE CAP ELEVATION. ALL PILE CAPS AND PILES SHALL BEAR ON SUBGRADE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. TOP OF PILE CAP ELEVATION IS AT REFERENCE ELEVATION UNLESS NOTED OTHERWISE. 4."PC#" INDICATES PILE CAP MARK. SEE TYPICAL PILE AND PILE CAP DETAILS AND SCHEDULES FOR SIZE, REINFORCING, AND ADDITIONAL INFORMATION. 5.COLUMNS SHOWN IN THE VIEW ARE PART OF THE MAIN LATERAL FORCE RESISTING SYSTEM. 6.REFERENCE ALL CONSTRUCTION DOCUMENTS FOR SIZE, EXTENT, AND LOCATION OF CONCRETE CURBS, HOUSEKEEPING PADS, CMU WALLS, PLANTER WALLS, BOLLARDS, EDGE ANGLES, AND SLAB PENETRATIONS. REINFORCE PER TYPICAL DETAILS. GENERAL NOTES: #4 @ 12" OC CONC PILASTER REINF NOT SHOWN CONC WALL REINF NOT SHOWN CL WALL CONC WALL CONTINUES WHERE OCCURS N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 7 : 5 5 A M BT120 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SFP231 12/10/2024R. PARGAS J. ALTCHECH OBSOLETE OVERALL FOUNDATION PLAN CHARGING GANTRYLPDDJPAE LPD AJF AE 1/8" = 1'-0" 12/10/2024 355ISSUED FOR BID SCALE IN FEET 4 0 88 16 SCALE: 1/8" = 1'-0" BT120 - OVERALL FOUNDATION PLAN - GANTRY 2 BT120-SGP100 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE: 1" = 1'-0" WALL/PILASTER REINFORCING DETAIL 1 - DELETED 1 06/13/2025 ADDENDUM #1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 10" SOG W/ #4 @ 12" T&B EW, SEE NOTE 4 6" SOG 5.25.1 5.B 5.A 16' - 10" 28 ' - 6 " 5' - 0"6' - 10"5' - 0" 5' - 0 " 18 ' - 6 " 5' - 0 " 2% SLOPE TO EDGE, TYP TOC EL 29'-6" NOTES: 1.LEVEL 01 - GENERATOR PAD REFERENCE ELEVATION IS PER CIVIL. REFER TO CIVIL DRAWINGS FOR ELEVATION, EXTENTS, AND SLOPE. 2.SLAB ON GRADE IS 6-INCHES THICK. REINFORCE PER TYPICAL DETAILS. SLAB ON GRADE SHALL BE PLACED ATOP COMPACTED STRUCTURAL FILL IN ACCORDANCE WITH GEOTECHNICAL REPORT. 3.REFERENCE ALL CONSTRUCTION DOCUMENTS FOR SIZE, EXTENT, AND LOCATION OF CONCRETE CURBS, HOUSEKEEPING PADS, CMU WALLS, PLANTER WALLS, BOLLARDS, EDGE ANGLES, AND SLAB PENETRATIONS. REINFORCE PER TYPICAL DETAILS. 4.INSTALL EQUIPMENT ANCHORAGE PER THE GENERATOR MANUFACTURER'S INSTRUCTIONS. GENERAL NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 7 : 5 6 A M BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SFP241 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL OVERALL FOUNDATION PLAN GENERATOR PADLPDDJPAE LPD AJF AE 1/8" = 1'-0" 12/10/2024 356ISSUED FOR BID SCALE: 1/8" = 1'-0"BT120-SFP001 FOUNDATION PLAN - GENERATOR PAD 1 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 1 1 11 06/13/2025 ADDENDUM #1 1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 1 0" SO G WG"/#OO S 4 / @ / " 1SS"#@"S G/4 2 OT # STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 1.B 1.C 1.1 1.2 1.3 1.4 14 ' - 0 " 5' - 8"24' - 0"24' - 0"24' - 0"5' - 8" MA T C H L I N E : SE E D W G B T 1 2 0 -SG P 3 1 3 A BT120-SGE111 B BT120-SGE111 TYP TYP 1 1/2" MTL DECK TY P , U N O TY P , U N O 2" 2" 3" HS S 8 X 4 X 1 / 4 HS S 8 X 4 X 1 / 4 HSS12X6X1/4 HSS12X6X1/4 HSS12X6X1/4, TYP UNO , TYP UNO , TYP UNO REFER TO ARCH DWGS FOR COLD FORMED FRAMING AROUND LIGHTS FALL ARREST ANCHOR, TYP C10X15.3 A 3' - 1 0 " 7' - 8 " 3' - 1 0 " 7' - 8 " 4" TYP B 2" TYP A B B BT120-SGD113 C BT120-SGD113 TYP (2) PLC 2" TYP 4" TYP HSS12X6X1/4, TYP UNO 1.A 14 ' - 0 " 3" A BT120-SGD112 SIM, TYP 3' - 6 " 3' - 6 " NOTES: 1.LEVEL 02 -CANOPY SECTOR A REFERENCE ELEVATION IS 37'-0". TOP OF STEEL ELEVATIONS IS AT REFERENCE ELEVATION. BOTTOM OF SLAB IS AT TOP OF STEEL ELEVATION. 2.THE STRUCTURAL SLAB IS A 1 1/2-INCH STEEL DECK. SEE THE TYPICAL ROOF DECK DETAILS. 3.CONTRACTOR SHALL COORDINATE ALL OPENINGS AND DEPRESSIONS PRIOR TO CONSTRUCTION. GENERAL NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 2 3 A M BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGP312 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL LEVEL 2 FRAMING PLAN CANOPY - SECTOR A LPD DJP AE LPD AJF AE 1/8" = 1'-0" 12/10/2024 357ISSUED FOR BID SCALE IN FEET 4 0 88 16 SCALE: 1/8" = 1'-0" FRAMING PLAN - CANOPY - SECTOR A 1 BT120-SGP100 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE IN FEET 4 0 88 16 1 06/13/2025 ADDENDUM #1 1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 1.B 1.C 1.5 1.6 1.7 MA T C H L I N E : SE E D W G B T 1 2 0 -SG P 3 1 2 M A T C H L I N E : S E E D W G B T 1 2 0 - S G P 3 1 4 5' - 8"24' - 0"24' - 0"5' - 8" A BT120-SGE111 B BT120-SGE111 TYP TYP 1 1/2" METAL DECK 14 ' - 0 " 14 ' - 0 " TY P , U N O TY P , U N O HS S 8 X 4 X 1 / 4 HS S 8 X 4 X 1 / 4 2" 2" REFER TO ARCH DWGS FOR COLD FORMED FRAMING AROUND LIGHTS FALL ARREST ANCHOR, TYP C10X15.3 A 4" TYP B 2" TYP 3' - 1 0 " 3' - 1 0 " 7' - 8 " 7' - 8 " A B 2" TYP 4" TYP C BT120-SGD113 1.A 3" 3 " HSS12X6X1/4, TYP UNO HSS12X6X1/4, TYP UNO A BT120-SGD112 SIM, TYP HSS12X6X1/4 HSS12X6X1/4 , TYP UNO , TYP UNO 3' - 6 " 3' - 6 " NOTES: 1.LEVEL 02 -CANOPY SECTOR B REFERENCE ELEVATION IS 39'-6". TOP OF STEEL ELEVATIONS IS AT REFERENCE ELEVATION. BOTTOM OF SLAB IS AT TOP OF STEEL ELEVATION. 2.THE STRUCTURAL SLAB IS A 1 1/2-INCH STEEL DECK. SEE THE TYPICAL ROOF DECK DETAILS. 3.CONTRACTOR SHALL COORDINATE ALL OPENINGS AND DEPRESSIONS PRIOR TO CONSTRUCTION. GENERAL NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 2 4 A M BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGP313 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL LEVEL 2 FRAMING PLAN CANOPY - SECTOR B LPD DJP AE LPD AJF AE 1/8" = 1'-0" 12/10/2024 358ISSUED FOR BID SCALE IN FEET 4 0 88 16 SCALE: 1/8" = 1'-0" FRAMING PLAN - CANOPY - SECTOR B 1 BT120-SGP100 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 1.E 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.15 5' - 8"24' - 0"24' - 0"24' - 0"24' - 0"24' - 0"24' - 0"24' - 0"5' - 8" MATCH LINE: SEE DWG BT120-SGP313 A BT120-SGE111 B BT120-SGE111 TYP TYP 1 1/2" METAL DECK TY P , U N O TY P , U N O HS S 8 X 4 X 1 / 4 HS S 8 X 4 X 1 / 4 HSS12X6X1/4 HSS12X6X1/4 2" 2" , TYP UNO , TYP UNO REFER TO ARCH DWGS FOR COLD FORMED FRAMING AROUND LIGHTS FALL ARREST ANCHOR, TYP C10X15.3 A B 2" TYP 4" TYP A B 2" TYP 4" TYP 3' - 1 0 " 3' - 1 0 " 7' - 8 " 7' - 8 " C BT120-SGD113 TYP, (5) PLC B 2" TYP B 2" TYP 1.F 1.D 14 ' - 0 " 14 ' - 0 " 3" 3" 2 ' - 0 " 2' - 0 " HSS12X6X1/4, TYP UNO HSS12X6X1/4, TYP UNO A BT120-SGD112 SIM, TYP 3' - 6 " 3' - 6 " NOTES: 1.LEVEL 02 -CANOPY SECTOR C REFERENCE ELEVATION IS 42'-0". TOP OF STEEL ELEVATIONS IS AT REFERENCE ELEVATION. BOTTOM OF SLAB IS AT TOP OF STEEL ELEVATION. 2.THE STRUCTURAL SLAB IS A 1 1/2-INCH STEEL DECK. SEE THE TYPICAL ROOF DECK DETAILS. 3.CONTRACTOR SHALL COORDINATE ALL OPENINGS AND DEPRESSIONS PRIOR TO CONSTRUCTION. GENERAL NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 2 5 A M BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGP314 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL LEVEL 2 FRAMING PLAN CANOPY - SECTOR C LPD DJP AE LPD AJF AE 1/8" = 1'-0" 12/10/2024 359ISSUED FOR BID SCALE IN FEET 4 0 88 16 SCALE: 1/8" = 1'-0" FRAMING PLAN - CANOPY - SECTOR C 1 BT120-SGP100 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 2.F 2.B 2.72.62.52.42.32.1 2.J 2.D 2.E2.E 2.112.102.92.8 2.A 2.A 2.C 2.2 2.G 2.H HSS6X4X5/16 HSS6X4X5/16 HSS6X4X5/16 HSS6X4X5/16 HSS4X4X1/4, TYP (8) PLC HSS6X4X5/16 HSS6X4X5/16 HS S 6 X 4 X 5 / 1 6 HSS6X4X5/16 FLAT HSS6X4X5/16 HS S 6 X 4 X 5 / 1 6 TOS EL 36'-0 1/2" TOS EL 36'-6", TYP AT HSS4X4 TOS EL 36'-0 1/2" TOS EL 36'-2" PL 1/2 PL 1/2 PL 1/2C5X6.7, SEE NOTE 1 6" TYP (4) EQ SPC (4) EQ SPC 6" (2 ) E Q S P C (3) EQ SPC 6" (2 ) E Q S P C PL1/2 X 4 1/2" X 3'-0", TYP UNO 6"(2) EQ SPC 6" (2 ) E Q S P C HSS6X4X5/16 TOS EL 36'-0 1/2" B BT120-SGD121 TYPA BT120-SGD121 TYP PL1/2 X 5" X 3'-8",TYP AT CORNERS C BT120-SGD121 C BT120-SGD121 SIM C BT120-SGD121 SIM A BT120-SGE124B BT120-SGE124 4 1 / 2 " 1' - 8 " FLAT 2' - 0" B BT120-SGD123 A BT120-SGD123 TYP (2) PLC R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 2 6 A M BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGP321 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL MISCELLANEOUS STEEL OVERALL FRAMING PLAN CORE FACILITYLPD DJP AE LPD AJF AE 3/16" = 1'-0" 12/10/2024 360ISSUED FOR BID SCALE: 3/16" = 1'-0"BT120-SFP001 MISCELLANEOUS STEEL FRAMING PLAN - CORE FACILITY 1 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N GENERAL NOTES: 1. CONTRACTOR TO PROVIDE SUPPORT FOR MECHANICAL, ELECTRICAL, AND PLUMBING EQUIPMENT. ATTACH TO PRIMARY STRUCTURE PER MANUFACTURER'S REQUIREMENTS. COORDINATE LOCATION OF EQUIPMENT SUPPORTS WITH MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. GENERAL NOTES: 1 06/13/2025 ADDENDUM #1 1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 NOTES: 1.LEVEL 02 -GANTRY REFERENCE ELEVATION IS 48'-0". REFERENCE CENTER OF STEEL ELEVATION IS AT REFERENCE ELEVATION. GENERAL NOTES: 3.A 3.B 3.3 3.43.2 97' - 0"6' - 0"97' - 0" 7' - 7 " HSS6X6X1/4 CHORD, TYP HSS4X4X1/4 DIAG, TYP UNO HSS4X4X1/4, TYP 3.1 - 1 TYP (12) PLC HSS4X4X5/16 DIAG HSS4X4X5/16 DIAG 3 BT120-SGD132 TYP, UNO 1 BT120-SGD133 TYP4 BT120-SGD132 OPP1 BT120-SGD131 4 BT120-SGD132A BT120-SGE131 3.A 3.B NOTES: 1.DIMENSIONS DENOTE PANTOGRAPH MOUNTING AREA LIMITS. PANTOGRAPH MOUNTING CONNECTION POINTS SHALL BE AT FOUR CORNERS OF THIS AREA, REFER TO ELECTRICAL DRAWINGS FOR LOCATION OF MOUNTING POINTS. VERIFY WITH PANTOGRAPH MANUFACTURER. 2.DIMENSIONS DENOTE PANTOGRAPH EXTENTS AREA LIMITS. VERIFY WITH PANTOGRAPH MANUFACTURER. 3.COORDINATE WITH ELECTRICAL AND CIVIL DRAWINGS FOR THE IN-PLAN DIMENSIONS AND ROTATION OF THE PANTOGRAPH, AS WELL AS THE MOUNTING ELEVATIONS, BEFORE INSTALLING THE PANTOGRAPH SUPPORTS. NOTES: PANTOGRAPH EXTENTS AREA LIMITS *SEE NOTES 1 & 3 **SEE NOTES 2 & 3 ***SEE NOTE 3 UNISTRUT, TYP (5) PLC HSS 4X4X1/4 HANGER, TYP (4) PLC PANTOGRAPH CONNECTION POINT, TYP *35.43 " *57.09" ** 49.21" ** 88.40" *** 6' - 2" A - HSS DIAG CENTERLINE HSS HANGERS AND PANTOGRAPGH MOUNTING AREA LIMITS 3' - 1" 3' - 1" 8 1/4" LEVEL 02 -GANTRY 48'-0" 27 " M A X 3" MOUNTING ELEV VARIES PER ELEC HSS BOTTOM CHORD HSS DIAG HSS HANGER, TYP CAP PL, TYP REF 35.43" 1/4 TYP 3-12 3-12 TYP P1000 P1001AWB - P2626 T&B, TYP P1726 T&B, TYP 1/ 4 " T Y P CL CHORD & HANGER CL CHORD & HANGER NOTES: 1. USE P1010 CHANNEL NUT WITH SPRING AND HEX HEAD CAP SCREWS AT ALL UNISTRUT CONNECTIONS. NOTES: HSS HANGER CL BT M C H OR D P1000, AT TOP ONLY P2079, AT TOP ONLY P1001AW PANTOGRAPH CONNECTION POINT AT BTM NOTES: 1. USE P1010 CHANNEL NUT WITH SPRING AND HEX HEAD CAP SCREWS AT ALL UNISTRUT CONNECTIONS. NOTES: NS & FS T & B N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 2 7 A M BT120 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGP331 12/10/2024R. PARGAS J. ALTCHECH OBSOLETE LEVEL 2 OVERALL FRAMING PLAN CHARGING GANTRYLPDDJPAE LPD AJF AE AS NOTED 12/10/2024 361ISSUED FOR BID SCALE IN FEET 4 0 88 16 SCALE: 1/8" = 1'-0" LEVEL 2 OVERALL FRAMING PLAN - GANTRY 2 BT120-SGP100 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE: 3/8" = 1'-0" PANTOGRAPH SUPPORT PLAN 1 -SCALE: 3/4" = 1'-0" PANTOGRAPH CONNECTION DETAIL A -SCALE: 1 1/2" = 1'-0" PANTOGRAPH CONNECTION DETAIL B - DELETED 1 06/13/2025 ADDENDUM #1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 N OTES: E1 .1TLV:: S L 0 E L T NSSTV0TS 1L 2 :- V STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 4.1 4.2 4.3 4.4 4.5 4.A 4.B 1 ' - 6 " 15 ' - 0 " 2' - 9 " 2'-6"18'-0"18'-0"18'-0"18'-0"2'-6" TYP, UNO TOS 42'-2" AT GRID 4.B HSS6X6X3/8 1' - 5"1' - 5" 2' - 0 " 4' - 6 1 / 2 " MF-3 MF-3 MF-3 MF-3 MF-3 MF-3 MF-3 MF - 1 MF - 1 MF - 1 MF - 1 MF - 2 MF-42' - 4 " HSS6X4X3/8 1' - 1 1 " HSS6X4X3/8 HSS6X4X3/8 HSS6X4X3/8 NOTES: 1.LEVEL 02 -BEB EQUIPMENT YARD REFERENCE ELEVATION IS 42'-9 1/2". TOP OF STEEL ELEVATIONS IS AT REFERENCE ELEVATION. BOTTOM OF SLAB IS AT TOP OF STEEL ELEVATION. 2.STEEL SLOPES UNIFORMLY BETWEEN GIVEN TOP OF STEEL ELEVATIONS SHOWN IN PLAN. WHERE BEAMS OF COLUMNS INTERSECT, MATCH THE TOP OF STEEL, UNLESS NOTED OTHERWISE. 3.THE STRUCTURAL SLAB IS A 1 1/2-INCH STEEL DECK. SEE THE TYPICAL ROOF DECK DETAILS. 4.CONTRACTOR SHALL COORDINATE ALL OPENINGS AND DEPRESSIONS PRIOR TO CONSTRUCTION. 5.SEE FRAMING ELEVATIONS FOR INFORMATION ON MAIN LATERAL FORCE-RESISTING SYSTEM. GENERAL NOTES: N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 2 8 A M BT120 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGP341 12/10/2024R. PARGAS J. ALTCHECH OBSOLETE ROOF OVERALL FRAMING PLAN BEB EQUIPMENT YARDLPDDJPAE LPD AJF AE 1/8" = 1'-0" 12/10/2024 362ISSUED FOR BID SCALE: 1/8" = 1'-0" ROOF FRAMING PLAN - BEB EQUIPMENT YARD 1 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE IN FEET 4 0 88 16 DELETED 1 06/13/2025 ADDENDUM #1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 2.F 2.B 2.72.62.52.42.32.1 2.J 2.D 2.E2.E 8' - 1"6' - 0"21' - 4"24' - 9"17' - 3"17' - 4"27' - 9"8' - 11"14' - 1"1' - 4" 2.112.102.92.8 2.A 2.A 2' - 8 " 10 ' - 9 " 2' - 0 " 2.C 2.2 2 1 / 2 " 4' - 0 " 11 ' - 5 " 6' - 0 " 2 1 / 2 " W12X14 W1 4 X 2 2 W12X14 W1 2 X 1 4 W1 2 X 1 4 W1 2 X 1 4 W1 4 X 2 2 W1 4 X 2 2 W1 4 X 2 2 BF -2. 2 MF -2. 1 1 MF -2. 9 BF-2.J MF-2.C MF-2.F TOS EL 39'-3 1/2 TOS EL 39'-6"TOS EL 38'-11 2.G 2.H 15 ' - 5 " 10 ' - 0 " 12 ' - 0 " 12 ' - 0 " 2 1 / 2 " BF -2. 2 W1 4 X 2 2 W1 4 X 2 2 W1 4 X 2 2 BF-2.E 7"7" 7"7" 7" W14X22 A BT120-SGE124B BT120-SGE124 7"HSS4X3X1/4 TOS EL 40'-2", TYPHSS4X4X3/8W14X22 1' - 7 1 / 2 " TOS EL 38'-8 1/2" NOTES: 1.LEVEL 02 -CORE FACILITY LOW ROOF REFERENCE ELEVATION IS 38'-8 1/2". TOP OF STEEL ELEVATIONS IS AT REFERENCE ELEVATION, UNLESS NOTED OTHERWISE. BOTTOM OF SLAB IS AT TOP OF STEEL ELEVATION. 2.STEEL SLOPES UNIFORMLY BETWEEN GIVEN TOP OF STEEL ELEVATIONS SHOWN IN PLAN. WHERE BEAMS OR COLUMNS INTERSECT, MATCH THE TOP OF STEEL, UNLESS NOTED OTHERWISE. 3.THE STRUCTURAL SLAB IS A 1 1/2-INCH STEEL DECK. SEE THE TYPICAL ROOF DECK DETAILS. 4.CONTRACTOR SHALL COORDINATE ALL OPENINGS AND DEPRESSIONS PRIOR TO CONSTRUCTION. 5.SEE FRAMING ELEVATIONS FOR INFORMATION ON THE MAIN LATERAL FORCE-RESISTING SYSTEM 6.REFER TO HIGH ROOF FRAMING PLAN FOR ADDITIONAL INFORMATION ON CORE FACILITY ROOF. GENERAL NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 2 9 A M BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGP421 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL LOW ROOF OVERALL FRAMING PLAN CORE FACILITYLPDDJPAE LPD AJF AE 3/16" = 1'-0" 12/10/2024 363ISSUED FOR BID SCALE: 3/16" = 1'-0"BT120-SFP001 LOW ROOF FRAMING PLAN - CORE FACILITY 1 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 NOTES: 1.LEVEL 03 -GANTRY REFERENCE ELEVATION IS 56'-6". REFERENCE CENTER OF STEEL ELEVATION IS AT REFERENCE ELEVATION. GENERAL NOTES: 3.A 3.B 3.3 3.43.2 C BT120-SGE131 D BT120-SGE131 TYP, (4) PLCS 8' - 1" 97' - 0"6' - 0"97' - 0" 7' - 7 " HSS6X6X1/4 CHORD, TYP DIAG, TYP HSS4X4X1/4, TYP HSS4X4X1/4 3.1 3 BT120-SGD132 TYP, UNO 1 BT120-SGD131 3 BT120-SGD132 SIM 1 BT120-SGD133 TYP A BT120-SGE131 N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 3 0 A M BT120 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGP431 12/10/2024R. PARGAS J. ALTCHECH OBSOLETE LEVEL 3 OVERALL FRAMING PLAN CHARGING GANTRYLPDDJPAE LPD AJF AE 1/8" = 1'-0" 12/10/2024 364ISSUED FOR BID SCALE IN FEET 4 0 88 16 SCALE: 1/8" = 1'-0"BT120-SGE131 LEVEL 3 OVERALL FRAMING PLAN - GANTRY 1 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N DELETED 1 06/13/2025 ADDENDUM #1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 N OTES: E1 .1TLV:: S L 0 E L T NSSTV0TS 1L 3 :- V STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 2.B 2.72.62.52.42.32.1 2.D 2.E2.E 2.112.102.92.8 2.A 8' - 1"6' - 0"21' - 4"24' - 9"17' - 3"17' - 4"27' - 9"8' - 11"14' - 1"1' - 4" 2.C 2.2 2' - 8 " 8' - 9 " 2' - 0 " 2' - 1 1 1 / 2 " 1 ' - 8 " 15 ' - 5 " 1 ' - 8 " TYP AT PERIMETER HSS6X4X1/4 BF -2. 4 BF -2. 7 BF-2.A BF-B BF-2.E FLAT, TY P , U N O W18X46 W18X46 W14X22 W14X22 W14X22 W14X22 W18X46 W12X35 W12X35 W10X26 W10X26 W10X12 W10X12 W10X12 W10X12 W14X22 W1 0 X 2 6 7"3" A BT120-SGE123 B BT120-SGE123 D BT120-SGE123 E BT120-SGE123 11 1 / 2 " 1' - 1 1 " 2' - 11" 3' - 2" TA P E R E D BELOW BELOW TOS EL 41'-3" AT GRID 2.A BELOW BELOW BELOW BELOW 7" BELOW 10' - 11 1/2" 9' - 1 1/2"1' - 7" HSS6X4X1/4 HSS6X4X1/4 3 BT120-SGD121 TYP (4) PLC D BT120-SGD121 TYP (4) PLC C BT120-SGE123 TYP @ TAPERED BEAM TOS EL 41'-10 1/2" NOTES: 1.LEVEL 03 -CORE FACILITY HIGH ROOF REFERENCE ELEVATION IS 41'-10 1/2". TOP OF STEEL ELEVATIONS IS AT REFERENCE ELEVATION, UNLESS NOTED OTHERWISE. BOTTOM OF SLAB IS AT TOP OF STEEL ELEVATION. 2.STEEL SLOPES UNIFORMLY BETWEEN GIVEN TOP OF STEEL ELEVATIONS SHOWN IN PLAN. WHERE BEAMS OR COLUMNS INTERSECT, MATCH THE TOP OF STEEL, UNLESS NOTED OTHERWISE. 3."BELOW" INDICATES BEAM IS LOCATED UNDERNEATH THE PERPENDICULAR BEAM FRAMING INTO IT. SEE TYPICAL STEEL DETAILS. 4.THE STRUCTURAL SLAB IS A 1 1/2-INCH STEEL DECK. SEE THE TYPICAL ROOF DECK DETAILS. 5.CONTRACTOR SHALL COORDINATE ALL OPENINGS AND DEPRESSIONS PRIOR TO CONSTRUCTION. 6.SEE FRAMING ELEVATIONS FOR INFORMATION ON THE MAIN LATERAL FORCE RESISTING SYSTEM. 7.REFER TO LOW ROOF FRAMING PLAN FOR ADDITIONAL INFORMATION ON CORE FACILITY ROOF. GENERAL NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 3 1 A M BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGP521 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL HIGH ROOF OVERALL FRAMING PLAN CORE FACILITYLPDDJPAE LPD AJF AE 3/16" = 1'-0" 12/10/2024 365ISSUED FOR BID SCALE: 3/16" = 1'-0"BT120-SFP001 HIGH ROOF FRAMING PLAN - CORE FACILITY 1 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 TOC PER PLAN TOS PER PLAN TOS PER PLAN GRIDGRID NOTES: 1.LOCATION OF MOUNTING PER ARCHITECT. CONTRACTOR TO COORDINATE. RTIS MOUNTING HANGERS, SEE NOTE 1 14' - 0"14' - 0" 1' - 3 " 2 BT120-SGD111 5 BT120-SGD111 SIM 3 BT120-SGD111 3 BT120-SGD111 1 BT120-SGD111 A BT120-SGD113 4 BT120-SGD111 5' - 1 0 " 11 1 / 2 " 3' - 9 " GRID WP GRIDGRID GRID 14' - 0"14' - 0" 3' - 9 " 11 1 / 2 " 1' - 3 " A BT120-SGD112 1 BT120-SGD112 A BT120-SGD112 SIM 2 BT120-SGD112 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 8 : 4 1 A M BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGE111 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL FRAMING ELEVATIONS CANOPYLPDDJPAE 3/8" = 1'-0" ISSUED FOR BID12/10/2024 SCALE: 3/8" = 1'-0"BT120-SFP212 SECTION AT CANOPY COLUMN A SCALE: 3/8" = 1'-0"BT120-SGP312 SECTION AT CANOPY B T OCPERP L CANRR E S A : P A C TEECN:CE A S 1 R. N GG54CGCRI F RPNTRE S A L OR I A E F R PN R P T L PI T NMC E C: E ET G F N GFR 15/Nov/2024 0366 RTA/CN 0205-24 CORE FACILITY - LEVEL 01 28' -2" 2.J 2.E HS S 6 X 6 X 1 / 4 HS S 6 X 6 X 1 / 4 HS S 6 X 6 X 1 / 4 W14X22 W14X22 H S S 4 X 4 X 1/ 4HSS4X4X1/4 2.G2.H HS S 6 X 6 X 1 / 4 TC1 BC2 TC3 BC13 CORE FACILITY - LEVEL 02 - LOW ROOF 38'-8 1/2" CORE FACILITY - LEVEL 01 28' -2" 2.E 2.A HS S 6 X 6 X 3 / 8 W10X22 H S S 4 X 4 X 1/4 HS S 6 X 6 X 3 / 8 H S S 4 X 4 X 1 /4 TC7 TC7 BC8 BC14 CORE FACILITY - LEVEL 02 - LOW ROOF 38'-8 1/2" CORE FACILITY - LEVEL 03 - HIGH ROOF 41'-10 1/2" CORE FACILITY - LEVEL 01 28' -2" 2.B2.E HS S 6 X 6 X 3 / 8 HS S 6 X 6 X 3 / 8 W10X26 H S S 5 X 5 X 5/1 6 H S S 5 X 5 X 5/1 6 TC9 TC9 BC10 BC14 CORE FACILITY - LEVEL 02 - LOW ROOF 38'-8 1/2" CORE FACILITY - LEVEL 03 - HIGH ROOF 41'-10 1/2" CORE FACILITY - LEVEL 01 28' -2" 2.F 2.C HS S 6 X 6 X 5 / 8 HS S 6 X 6 X 5 / 8 HSS4X4X3/8 W14X22 HSS3X3X1/4 1 BT120-SGD121 OPP 2 BT120-SGD121 OPP CORE FACILITY - LEVEL 02 - LOW ROOF 38'-8 1/2" CORE FACILITY - LEVEL 03 - HIGH ROOF 41'-10 1/2" 7 BT120-SGD123 TYP CORE FACILITY - LEVEL 01 28' -2" 2.F 2.C HS S 6 X 6 X 5 / 8 HS S 6 X 6 X 5 / 8 W14X22 CORE FACILITY - LEVEL 02 - LOW ROOF 38'-8 1/2" 7 BT120-SGD123 TYP GENERAL NOTES: 1. SINGLE LINE DIAGRAMS INDICATE CENTROIDIAL AXIS OF THE MEMBER UNLESS NOTED OTHERWISE. DIMENSIONS NOTED ARE TO THE CENTERLINE OF ALL ELEMENTS SHOWN. 2. ALL WORK POINTS AND DIMENSIONS SHOWN ARE THEORETICAL AND BASED ON THE ASSUMED FINAL AS-BUILT GEOMETRY. THE CONTRACTOR SHALL VERIFY ALL GEOMETRY BASED ON CONNECTIONS, FABRICATION/ERECTION TOLERANCES, AND THEIR MEANS AND METHODS OF CONSTRUCTION. 3. SEE PLANS FOR BEAM ELEVATIONS UNLESS NOTED OTHERWISE. 4. BRACED FRAME CONNECTION CONFIGURATIONS SHALL BE COORDINATED WITH DOORWAYS, CEILINGS, AND MECHANICAL/ELECTRICAL SYSTEMS. 5. INDICATES COLUMN BASE PER THE BRACED FRAME AND MOMENT FRAME TYPICAL DETAILS. 6. ALL MEMBERS ON THIS SHEET ARE PART OF THE MAIN LATERAL FORCE RESISTING SYSTEM. 7. SEE TYPICAL BRACED FRAME AND MOMENTS FRAME TYPICAL DETAILS FOR ADDITIONAL NOTES AND CONNECTION INFORMATION. R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 8 : 4 3 A M BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGE121 09/06/2024R. PARGAS J. ALTCHECH STRUCTURAL FRAMING ELEVATIONS CORE FACILITYLPDDJPAE 3/16" = 1'-0" ISSUED FOR BID12/10/2024 SCALE: 3/16" = 1'-0" BF-2.2 BRACED FRAME ELEVATION A BT120-SGP321 SCALE: 3/16" = 1'-0" BF-2.4 BRACED FRAME ELEVATION B BT120-SGP421 SCALE: 3/16" = 1'-0" BF-2.7 BRACED FRAME ELEVATION C BT120-SGP421 SCALE: 3/16" = 1'-0" MF-2.9 MOMENT FRAME ELEVATION E BT120-SGP321SCALE: 3/16" = 1'-0" MF-2.11 MOMENT FRAME ELEVATION D BT120-SGP321 C ORE FEA IARLTFF Y L - E L R C RT-R ALYVF0 T 22HCI2I.1 2 RPNTRE S A L OR I A E F R PN F E C AI E1C T8R R - C G F N GFR 15/Nov/2024 0367 RTA/CN 0205-24 CORE FACILITY - LEVEL 01 28' -2" 2.112.9 PE R M F -2. 9 PE R M F -2. 1 1 W14X22 CORE FACILITY - LEVEL 02 - LOW ROOF 38'-8 1/2" 7 BT120-SGD123 TYP CORE FACILITY - LEVEL 01 28' -2" 2.32.2 H S S 4 X 4 X 1/4 HS S 6 X 6 X 1 / 4 W14X22 PE R B F -2. 2 TC5 BC6 CORE FACILITY - LEVEL 02 - LOW ROOF 38'-8 1/2" CORE FACILITY - LEVEL 01 28' -2" 2.32.2 HS S 6 X 6 X 1 / 4 W14X22 PE R B F -2. 2 TC5 TC5 BC13 BC6 E BT120-SGD121 CORE FACILITY - LEVEL 02 - LOW ROOF 38'-8 1/2" CORE FACILITY - LEVEL 03 - HIGH ROOF 41'-10 1/2"W14X22 H S S 4 X 4 X 1/4HSS4X4X1/4 CORE FACILITY - LEVEL 01 28' -2" 2.52.4 H S S 5 X 5 X 1/4 H S S 5 X 5 X 1/4 HS S 6 X 6 X 3 / 8 W18X46 PE R B F -2. 4 TC11 BC14 BC12 CORE FACILITY - LEVEL 02 - LOW ROOF 38'-8 1/2" CORE FACILITY - LEVEL 03 - HIGH ROOF 41'-10 1/2" CORE FACILITY - LEVEL 01 28' -2" 2.7 2.8 HS S 6 X 6 X 3 / 8 H S S 5 X 5 X 1/4HSS5X5X1/4 W18X46 PE R B F -2. 7 TC11 BC14 BC12 CORE FACILITY - LEVEL 02 - LOW ROOF 38'-8 1/2" CORE FACILITY - LEVEL 03 - HIGH ROOF 41'-10 1/2" CORE FACILITY - LEVEL 01 28' -2" 2.112.9 PE R M F 2 . 9 PE R M F 2 . 1 1 H S S 3 X 3 X 1 /4 HSS4X4X3/8 W14X22 2 BT120-SGD121 1 BT120-SGD121 CORE FACILITY - LEVEL 02 - LOW ROOF 38'-8 1/2" CORE FACILITY - LEVEL 03 - HIGH ROOF 41'-10 1/2" 7 BT120-SGD123 TYP GENERAL NOTES: 1. SINGLE LINE DIAGRAMS INDICATE CENTROIDIAL AXIS OF THE MEMBER UNLESS NOTED OTHERWISE. DIMENSIONS NOTED ARE TO THE CENTERLINE OF ALL ELEMENTS SHOWN. 2. ALL WORK POINTS AND DIMENSIONS SHOWN ARE THEORETICAL AND BASED ON THE ASSUMED FINAL AS-BUILT GEOMETRY. THE CONTRACTOR SHALL VERIFY ALL GEOMETRY BASED ON CONNECTIONS, FABRICATION/ERECTION TOLERANCES, AND THEIR MEANS AND METHODS OF CONSTRUCTION. 3. SEE PLANS FOR BEAM ELEVATIONS UNLESS NOTED OTHERWISE. 4. BRACED FRAME CONNECTION CONFIGURATIONS SHALL BE COORDINATED WITH DOORWAYS, CEILINGS, AND MECHANICAL/ELECTRICAL SYSTEMS. 5. INDICATES COLUMN BASE PER THE BRACED FRAME AND MOMENT FRAME TYPICAL DETAILS. 6. ALL MEMBERS ON THIS SHEET ARE PART OF THE MAIN LATERAL FORCE RESISTING SYSTEM. 7. SEE TYPICAL BRACED FRAME AND MOMENTS FRAME TYPICAL DETAILS FOR ADDITIONAL NOTES AND CONNECTION INFORMATION. R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 8 : 4 5 A M BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGE122 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL FRAMING ELEVATIONS CORE FACILITYLPDDJPAE 3/16" = 1'-0" ISSUED FOR BID12/10/2024 SCALE: 3/16" = 1'-0" MF-2.F MOMENT FRAME ELEVATION E BT120-SGP421SCALE: 3/16" = 1'-0" BF-2.J BRACED FRAME ELEVATION D BT120-SGP321 SCALE: 3/16" = 1'-0" BF-2.E BRACED FRAME ELEVATION C BT120-SGP421SCALE: 3/16" = 1'-0" BF-2.A BRACED FRAME ELEVATION A BT120-SGP421 SCALE: 3/16" = 1'-0" BF-2.B BRACED FRAME ELEVATION B BT120-SGP421 SCALE: 3/16" = 1'-0" MF-2.C MOMENT FRAME ELEVATION F BT120-SGP421 C ORE FEA IARLTFF Y L - E L R C RT-R ALYVF0 T 2238I2I.1 2 RPNTRE S A L OR I A E F R PN F E C AI E1C T8R R - C G F N GFR 15/Nov/2024 0368 RTA/CN 0205-24 CORE FACILITY - LEVEL 01 28' -2" 2.E 2.A NOTES: 1.VIEW FOR INFORMATION ONLY. NOTES: CORE FACILITY - LEVEL 02 - LOW ROOF 38'-8 1/2" CORE FACILITY - LEVEL 03 - HIGH ROOF 41'-10 1/2" CORE FACILITY - LEVEL 01 28' -2" 2.B2.D NOTES: 1.VIEW FOR INFORMATION ONLY. NOTES: CORE FACILITY - LEVEL 03 - HIGH ROOF 41'-10 1/2" CORE FACILITY - LEVEL 01 28' -2" 2.B2.E NOTES: 1.VIEW FOR INFORMATION ONLY. NOTES: CORE FACILITY - LEVEL 03 - HIGH ROOF 41'-10 1/2" CORE FACILITY - LEVEL 01 28' -2" 2.E 2.C NOTES: 1.VIEW FOR INFORMATION ONLY. NOTES: CORE FACILITY - LEVEL 03 - HIGH ROOF 41'-10 1/2" 2.E 2.A PER PLAN PER PLAN 4"4"TAPERED BEAM SUPPORT NOT SHOWN, SEE NOTE 1 TAPERED BEAM L4X4X1/4X0'-3" ES, TYP 1/4 (3) SIDES, TYP 1/2" TYP CL TAPERED BEAM1' - 6" PL1/4X3X0'-6" T&B 3/16 (3) SIDES, TYP NS& FS 1. TAPERED BEAM MAY BE SUPPORTED BY GIRDER BELOW, COLUMN BELOW, OR CANTILEVER THROUGH IN-PLANE GIRDER. REFER TO THE PLAN FOR THE APPLICABLE CONDITION. 2. SPLICE PERIMETER HSS AS INDICATED WHERE REQUIRED. NOTES: FLAT HSS AT PRMT, SEE NOTE 2 4" TYP R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 8 : 4 6 A M BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGE123 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL FRAMING ELEVATIONS CORE FACILITYLPDDJPAEISSUED FOR BID12/10/2024 SCALE: 1/4" = 1'-0"BT120-SGP521 SECTION @ GRID 2.3 A SCALE: 1/4" = 1'-0" SECTION @ GRID 2.6 B SCALE: 1/4" = 1'-0" SECTION NEAR GRID 2.7 D SCALE: 1/4" = 1'-0" SECTION NEAR GRID 2.8 E BT120-SGP521 BT120-SGP521 BT120-SGP521BT120-SGP521 SCALE: 1 1/2" = 1'-0"BT120-SGP521 HIGH ROOF TAPERED BEAM DETAIL C C ORE FEA IARLTFF Y L - E L R C RT-R ALYVF0 T 22OB-2-.1 2 RPNTRE S A L OR I A E F R PN F E C AI E1C T8R R - C G F N GFR 15/Nov/2024 0369 RTA/CN 0205-24 2.72.62.5 2.8 TOS HVAC CAGE 36' -6"HS S 4 X 4 X 1 / 4 17' - 4"17' - 3"24' - 9" TY P HSS4X3X1/4 HSS4X4X1/4 HSS4X3X1/4 HSS4X3X1/4 HSS4X3X1/4 HSS4X4X1/4 HSS4X3X1/4 HSS4X3X1/4 HSS4X3X1/4 HSS4X4X1/4 EDGE BEAM BEYOND A BT120-SGD122 TYP (3) PLC @ GRID TYP UNOB BT120-SGD122 1 BT120-SGD123 4 BT120-SGD123 SIM 2.72.62.5 2.8 TOS HVAC CAGE 36' -6" 17' - 4"17' - 3"24' - 9" HSS COL HSS4X4X1/4 HSS4X4X1/4 HSS4X4X1/4 HSS2X2X1/4 HS S 4 X 4 X 1 / 4 TY P A BT120-SGD122 TYP (3) PLC @ GRID TYP UNOB BT120-SGD122 2 BT120-SGD123 5 BT120-SGD123 6 BT120-SGD123 4 BT120-SGD123 3 BT120-SGD123 H S S 2 X 2 X 1 /4 4 BT120-SGD123 SIM5 BT120-SGD123 SIM R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 8 : 4 7 A M 1/4" = 1'-0" BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGE124 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL FRAMING ELEVATIONS CORE FACILITYLPDDJPAEISSUED FOR BID12/10/2024 SCALE: 1/4" = 1'-0"BT120-SGP321 WEST ELEVATION AT MECH CAGE A SCALE: 1/4" = 1'-0"BT120-SGP321 WEST ELEVATION AT MECH CAGE B 2 .76586A BA714885 3 1 S 6 1 7 25574S75 A13T8R 4 TTVE2T2OI D RPNTRE S A L OR I A E F R PN 8 6 2 AB 6I 2 4 E7 5 7 S 552 G F N GFR 15/Nov/2024 0370 RTA/CN 0205-24 3.3 3.43.2 97' - 0"6' - 0"97' - 0" HSS4X4X1/4 DIAG, TYP 3.1 CONC WALL TOC EL 30'-6", TYP PILES, TYP PILE CAP, TYP TOC EL PER PLAN SPLICE, SEE NOTE 4 3 BT120-SGD131 TYP 1 BT120-SGD131 SIM 1 BT120-SGD132 2 BT120-SGD132 4 BT120-SGD131 OPP HSS4X4X1/4, TYP 2 BT120-SGD131 SIM 1 BT120-SGD132 SIM PANTOGRAPH MOUNTING STRUCTURE NOT SHOWN FOR CLARITY 24" X 24" CONC PEDESTAL TOC EL 30'-6", TYP TYP 3.A 3.B LEVEL 03 - GANTRY 56' -6" LEVEL 02 - GANTRY 48' -0" HSS4X4X1/4 HSS4X4X1/4 HSS4X4X1/4 TYP, UNO PER PLAN TOC 4 BT120-SGD131 TYP 1 BT120-SGD131 TYP 2 BT120-SGD131 TYP 7' - 7" LEVEL 03 - GANTRY 56' -6" LEVEL 02 - GANTRY 48' -0" HSS4x4x1/4, TYP 2' - 7 " 4' - 1 1 " TYP 1' - 8" 1' - 0 " CHORD AND DIAG BEYOND, TYP 3.A 3.B LEVEL 03 - GANTRY 56' -6" LEVEL 02 - GANTRY 48' -0" B - 2' - 4" HSS4X4X1/4 HSS4X4X1/4 HS S 4 X 4 X 1 / 4 CHORD, TYP ACM MODULE EXTENTS 3 BT120-SGD133 2 BT120-SGD133 A BT120-SGD133 TYP 3 BT120-SGD133 TYP NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR ACM MODULE LOCATION. VERIFY ACM MODULE SUPPORT WITH ACM MODULE MANUFACTURER. 2. PANTOGRAPH SUPPORT NOT SHOWN FOR CLARITY. NOTES: OPP DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 2 1 A M BT120 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGE131 12/10/2024R. PARGAS J. ALTCHECH OBSOLETE FRAMING ELEVATIONS CHARGING GANTRYLPDDJPAE LPD AJF AE 12/10/2024 371ISSUED FOR BID SCALE: 1/8" = 1'-0"BT120-SFP231 SOUTH GANTRY FRAMING ELEVATION C SCALE: 1/8" = 1'-0"BT120-SFP231 WEST GANTRY FRAMING ELEVATION D NOTES: 1.FOR QUANTITY TAKEOFF PURPOSES, INCREASE THE TONNAGE OF STEEL BY 10%. 2.ALL GUSSETS AND STIFFENERS SHALL MATCH THE GRADE OF THE INCOMING BEAM. 3.REFERENCE ELEVATIONS AT TRUSS ARE TO THE CENTERLINE OF THE TRUSS CORNERS. 4.SPLICE EXISTENCE AND LOCATION IS PER THE CONTRACTOR. PROVIDED DETAIL IS OPTIONAL. CONSTRUCTION OF GANTRY, INCLUDING ANY SEQUENCING AND TEMPORARY BRACING, IS PER THE CONTRACTOR. 5.AN ERECTION SEQUENCING PLAN SHALL BE SUBMITTED PRIOR TO CONSTRUCTION. THERE SHALL BE AT LEAST TWO PICK POINTS PER TRUSS SEGMENT. PICK POINTS SHALL BE AT THE NODES OF THE TRUSS. GENERAL NOTES: SCALE: 3/8" = 1'-0" ACM MODULE SUPPORT ELEVATION B -SCALE: 3/8" = 1'-0"BT120-SGP331 ACM MODULE SUPPORT SIDE ELEVATION A DELETED 1 06/13/2025 ADDENDUM #1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 LEVEL 01 -BEB EQUIPMENT YARD 29' -6" 4.A4.B LEVEL 02 -BEB EQUIPMENT YARD 42' -9 1/2"HSS6X6X3/8 HS S 8 X 8 X 3 / 8 HS S 8 X 8 X 3 / 8 1 BT120-SGD111 TYP LEVEL 01 -BEB EQUIPMENT YARD 29' -6" 4.A 4.B LEVEL 02 -BEB EQUIPMENT YARD 42' -9 1/2" 1 BT120-SGD111 TYP HS S 8 X 8 X 3 / 8 HS S 8 X 8 X 3 / 8 LEVEL 01 -BEB EQUIPMENT YARD 29' -6" LEVEL 02 -BEB EQUIPMENT YARD 42' -9 1/2" 1 BT120-SGD111 TYP HSS6X6X3/8 GRID GRID PE R M F - 1 PE R M F - 1 LEVEL 01 -BEB EQUIPMENT YARD 29' -6" LEVEL 02 -BEB EQUIPMENT YARD 42' -9 1/2" 1 BT120-SGD111 TYP HSS6X6X3/8 PE R M F - 1 PE R M F - 2 GENERAL NOTES: 1. SINGLE LINE DIAGRAMS INDICATE CENTROIDIAL AXIS OF THE MEMBER UNLESS NOTED OTHERWISE. DIMENSIONS NOTED ARE TO THE CENTERLINE OF ALL ELEMENTS SHOWN. 2. ALL WORK POINTS AND DIMENSIONS SHOWN ARE THEORETICAL AND BASED ON THE ASSUMED FINAL AS-BUILT GEOMETRY. THE CONTRACTOR SHALL VERIFY ALL GEOMETRY BASED ON CONNECTIONS, FABRICATION/ERECTION TOLERANCES, AND THEIR MEANS AND METHODS OF CONSTRUCTION. 3. SEE PLANS FOR BEAM ELEVATIONS UNLESS NOTED OTHERWISE. 4. INDICATES COLUMN BASE PER THE BRACED FRAME AND MOMENT FRAME TYPICAL DETAILS. 5. ALL MEMBERS ON THIS SHEET ARE PART OF THE MAIN LATERAL FORCE RESISTING SYSTEM. 6. SEE TYPICAL BRACED FRAME AND MOMENTS FRAME TYPICAL DETAILS FOR ADDITIONAL NOTES AND CONNECTION INFORMATION. DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 2 2 A M BT120 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 M. BUNIYA R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGE141 12/10/2024R. PARGAS J. ALTCHECH OBSOLETE FRAMING ELEVATIONS BEB EQUIPMENT YARDMKBDJPAE MKB AJF AE 1/4" = 1'-0" 12/10/2024 372ISSUED FOR BID SCALE: 1/4" = 1'-0" MF-1 MOMENT FRAME ELEVATION A BT120-SGP341 SCALE: 1/4" = 1'-0" MF-2 MOMENT FRAME ELEVATION B BT120-SGP341 SCALE: 1/4" = 1'-0" MF-3 MOMENT FRAME ELEVATION C BT120-SGP341 SCALE: 1/4" = 1'-0" MF-4 MOMENT FRAME ELEVATION D BT120-SGP341 DELETED 1 06/13/2025 ADDENDUM #1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 L EV 01 - B-VQU11 0 I Q P Q V L00VUPV0 -Q I M 1N U STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 SLAB REINF VAPOR RETARDER NOTE 8 GRANULAR FILL 6 " SO G T H K NO T E 1 NOTES: 1. SEE PLANS FOR SLAB ON GRADE THICKNESS. SLAB ON GRADE IS 6-INCH THICK UNLESS NOTED OTHERWISE. 2.REINFORCE UP TO 4-INCH THICK SLAB ON GRADE WITH #4 @ 18" EACH WAY, UP TO 6-INCH THICK SLAB ON GRADE WITH #4 @ 16" EACH WAY, UP TO 9-INCH THICK SLAB ON GRADE WITH #4 @ 16" EACH WAY TOP AND BOTTOM. 3.LOCATE CONSTRUCTION JOINTS UNDER PARTITIONS OR ON COLUMN LINES. 4.PROVIDE CONTROL JOINTS AT A MAXIMUM SPACING OF 20-FEET EACH WAY IN BETWEEN. PROVIDE CONTROL JOINTS AT ALL RE- ENTRANT CORNERS. 5.SUBMIT A JOINTING PLAN TO ARCHITECT FOR REVIEW. 6.AT STRUCTURAL SLAB, EXTEND ADDED BAR 24-INCHES INTO SLAB. AT CONTRACTOR'S OPTION, FORMSAVER IS ACCEPTABLE. 7.OVEREXCAVATE TO A DEPTH OF 12 INCHES BELOW BOTTOM OF FOUNDATION, MOISTURE-CONDITION, PROCESS, AND RECOMPACT TO 90 PERCENT PER GEOTECHNICAL RECOMMENDATIONS FOR SHALLOW FOUNDATIONS. THIS NOTE APPLIES TO NON PILE SUPPORTED SLABS ON GRADE ONLY. 8.VAPOR RETARDER IS REQUIRED ONLY AT INTERIOR SLABS ON GRADE. CLEAR 1 1/2" ISOLATION JOINT (IJ)AT COLUMN TOOLED ISOLATION JOINT TERMINATE REINF AT JOINT BOND BREAKER FILL IN W/ CONC AFTER FORMS ARE REMOVEDIJ2" TYP CJ CJ CJIJIJIJCONSTRUCTION JOINT (CJ) SAWCUT QUARTER OF SOG THK TERMINATE REINF AT JOINT 3/4" Ø X 2'-0" SMOOTH DOWEL, CENTER IN SLAB, MATCH SOG REINF SPCG SLAB ON GRADE JOINTS, DISCONTINUOUS AT INTERSECTION WITH PERPENDICULAR JOINT (2) #4 X 4'-0" AT MID- DEPTH SOG RE-ENTRANT CORNER CJ CJ CJ 4" 2" CLR (2) #4 X 4'-0" AT MID-DEPTH SOG CONTROL JOINT (CJ) SAWCUT QUARTER OF SOG THK SOG CJ INTERSECTION RE-ENTRANT CORNER AT PILASTER FILL IN W/ CONC AFTER FORMS ARE REMOVED CJIJIJSTRUC SLAB STRUC WALL 2'-0" SOG, REINF NOT SHOWN MATCH SIZE AND SPCG OF SOG, SEE NOTE 6 WATERSTOP PER ARCH 3/4"x3 1/2"x0'-6" KEYED JT SLAB/WALL INTERSECTION 4 " C L R , T Y P #4 X 2'-0" WHERE NO CJ OCCURS #4 EDGE BAR, TYP NOTES: 9" MAX.(2) #5 CONT, LAP 2'-6" #4 @ 12" 3/4" CHAMFER CONC SLAB, SEE NOTE 2 12" MAX. #5 CONT, LAP 2'-6"NOTES: 1. SEE ARCHITECTURAL DRAWINGS FOR CURB DIMENSIONS AND LOCATIONS. 2.MINIMUM THICKNESS OF CONCRETE ELEMENT WHERE THIS DETAIL APPLIES IS 4 INCHES. 3.FOR CURBS ON SLAB ON METAL DECK, PLACE HOOK AND CONTINUOUS BOTTOM BAR AT BOTTOM OF FLUTE. 4.INFORM THE STRUCTURAL ENGINEER WHERE CURB IS SHOWN THAT FALLS OUTSIDE OF THE LIMITS OF THIS DETAIL. NOTES: (2) #4 CONT, LAP 2'-6", HOOK AT ENDS 2'-6" SOG 1' - 3" 1' - 0" #4 @ 16" 1 1 L , SEE NOTE 2 S S SOG EDGE L S MIN 1" 3" 2" 6" 4" 9" 6"18" NOTES: 1. DO NOT MOVE OR CUT REINFORCING BARS. 2. REQUIRED SPACING BETWEEN PENETRATIONS SHALL BE CHOSEN USING THE LARGER PENETRATION. 3. FOR LARGER SLAB ON GRADE PENETRATIONS OR FOR PENETRATIONS SPACED TOO CLOSE TO EACH OTHER, REINFORCE PER 'TYPICAL CONCRETE WALL OR SLAB OPENING DETAIL'. NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-S-v2020.rvt 11/14/2024 11:09:00 AM BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGY401 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL TYPICAL FOUNDATION DETAILS 1LPDDJPAEISSUED FOR BID12/10/2024 SCALE: NTS TYPICAL - SLAB ON GRADE DETAILS 1 -SCALE: NTS TYPICAL CONCRETE CURB DETAILS 2 - SCALE: NTS TYPICAL SLAB ON GRADE EDGE 3 -SCALE: NTS TYPICAL SLAB ON GRADE OPENING DETAIL 4 S LAB RBE IEANFRR V N P B N A S AFPA ENVORT F D 8 I SOLIA T N JI ( N A ) I S O R B S EI BDS FGA A P S C ) O C)I 15/Nov/2024 0373 RTA/CN 0205-24 CL PILE CAP TERMINATOR, TYP EXTEND PILE REINF TO TOP OF PILE CAP (6)#5 VERT #3 SPIRAL W/ 3" PITCH, TYP (1) #10 VERT, TYP TOP OF PILE CAP EL. 18" DIA CIP AUGER CAST PILE, TYP 3" TYP 2" CLR 4" C L R SE E S C H E D TH I C K N E S S SEE SCHED 6" TY P 2" C L R 66 ' - 0 " 3" CLR TYPICAL PILE CAP SECTION 5 2 ' - 0 " CL PILE CAP SEE SCHED PILE CAP THK, CLR 4" PILE CAP, SEE PLANS AND SCHED FOR DIMS, SEE NOTE 4 SOG REINF PILE, REINF PER TYP SECTION #6 @ 12" EW PC1 SECTION NOTES: 1.REFER TO TYPICAL BASE PLATE RECESS AT CORE FACILITY DETAIL. 2.REFER TO THE GEOTECHNICAL REPORT FOR INFORMATION ON PILE INSTALLATION AND SOIL PREPARATION. PROVIDE A TEMPORARY CASING TO A DEPTH OF 10 FEET, REMOVE THE SOIL INSIDE OF THE CASING, PROPERLY DISPOSE OF IT, AND SEAL BOTTOM TWO FEET OF CASING WITH BENTONITE GROUT PRIOR TO AUGERING BELOW CASING. REMOVE TEMPORARY CASING AFTER COMPLETION OF PILE GROUTING. 3.AT CONTRACTOR'S OPTION, SLOPE SUBGRADE AT 1:1 IN LIEU OF STEPPED BOTTOM OF FOUNDATION. 4.WHERE A COLUMN LANDS ON A PILE CAP AND THE BASE PLATE EXTENDS BEYOND THE EDGE OF THE PILE CAP, LOCALLY INCREASE DIMENSION OF PILE CAP SUCH THAT IT ENDS 3- INCHES BEYOND THE BASE PLATE EDGE. NOTES: PILE CAP SCHEDULE MARK THICKNESS BOTTOM REINFORCING PC2 24"(5) #7 LONG DIRECTION SHORT DIRECTION TOP REINFORCING LONG DIRECTION SHORT DIRECTION (10) #7 (5) #7 (10) #7 PC2A 24"(5) #7 (11) #7 (5) #7 (11) #7 PC8 24"(12) #8 (22) #8 (12) #8 (22) #8 PC1 22"SEE PC1 SECTION SEE PC1 SECTION SEE SOG REINF SEE SOG REINF SEE NOTE 3 PC2A PILE CAP PLAN 2' - 3"2' - 3" 2' - 3" 3' - 0" 3' - 0" 2' - 3" 2' - 3"2' - 3"2' - 3"2' - 3" PC2 PILE CAP PLAN 2' - 3"2' - 3" 2' - 3" 2' - 3" 2' - 3" 2' - 3" PC8 PILE CAP PLAN 2' - 3" 6' - 0" 3' - 0" 3' - 0" 6' - 0" 2' - 3" LONG DIRECTION REINF, TYP SHORT DIRECTION REINF, TYP NOTES: 1. EXTEND REINFORCING INTO FOOTING 3'-0" OR PROVIDE Ldh AND HOOK. SPLICE BARS AS REQUIRED. 2.TOP OF GRADE BEAM ELEVATION TO MATCH TOP OF FOOTINGS, UNLESS NOTED OTHERWISE. 3.LOCATE CJ WITHIN MIDDLE THIRD OF SPAN. ONE CJ PER GRADE BEAM. PROVIDE FULL WIDTH SHEAR KEY AT CJ. 4.WHERE LONGITUDINAL REINFORCING IS IN CONFLICT WITH FOOTING, ACCEPTABLE TO LOCALLY BEND GRADE BEAM BARS. GRADE BEAM SCHEDULE MARK SIZE LONGITUDINAL REINF SHEAR REINF GB12X12 12" 12" (4) #6 (4) #6 #3 12" 'W''D'TOP REINF BOT REINF SIZE SPACING WIDTH 'W' DEPTH 'D' TOP REINF, SEE NOTE 1 TIES TO START 2" CLR FROM FACE OF FOOTING BOT REINF, SEE NOTE 1 NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-S-v2020.rvt 6/2/2025 11:28:32 AM BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGY402 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL TYPICAL FOUNDATION DETAILS 2LPDDJPAE LPD AJF AE 12/10/2024 374ISSUED FOR BID SCALE: NTS TYPICAL CONCRETE PILE CAP PLANS AND SECTIONS 3 - SCALE: NTS TYPICAL GRADE BEAM DETAIL AND SCHEDULE 2 - 1 1 06/13/2025 ADDENDUM #1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 C LPIE I A TAPRM E N R O I R P CEEPMOPE ARN, Y M STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 6' - 0" 2' - 0 " A - NOTES: 1. REFER TO ARCHITECTURAL DRAWINGS FOR PYLON LOCATIONS. 2. REFER TO SYSTEM AND ELECTRICAL DRAWINGS FOR CONDUIT INFORMATION. NOTES: 5' - 0 " CL CL 1' - 8 1/2" TYP 3 1/4" TYP 4 1/2" 1' - 6" 1' - 6" (4) 3/4" DIA AR W/ 1'-4" EMBED, TYP CONDUIT WHERE OCCURS #5 @ 12" EW 1' - 0" 1' - 6" #5 @ 12" T&B EW HOOK INWARD WHERE REQUIRED SOG PLATFORM (3) #4 @ 3" JOINT FILLER AT PRMT 4" TYP 1' - 0" B - NOTES: 1. REFER TO ARCHITECTURAL DRAWINGS FOR ELECTRICAL CABINET LOCATIONS. 2. REFER TO SYSTEM AND ELECTRICAL DRAWINGS FOR CONDUIT INFORMATION. 3. WHERE TWO CABINETS ARE WITHIN 1'-6" OF EACH OTHER, COMBINE THEIR PERIMETER AND PLACE THEM ON THE SAME FOUNDATION. NOTES: CONDUIT WHERE OCCURS CABINET(S) PRMT, SEE NOTE 3 4" TYP #4 @ 12" EW #4 @ 12" T&B EWHOOK INWARD WHERE REQUIRED SOG PLATFORM 6" 1' - 0" JOINT FILLER AT PRMT CHAMFER PRMT 4" SPIRAL PITCH PITCH 9" SPIRAL MAX 3' - 0" 5'-0" FOR 25FT POLES 4' - 0" FOR 15FT POLES 2' - 0" POLE NOTE 1 BASE PLATE AND ANCHOR ROD NOTE 1 SOG WHERE OCCURS ABOVE GRADE POLE FOUNDATION NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR POLE INFORMATION. POLE AND BASE CONNECTION PER POLE MANUFACTURER. 2. AT CONTRACTOR'S OPTION, SUBSTITUTE SPIRALS WITH TIES. 3. REFER TO GEOTECHNICAL REPORT FOR SOIL PREPARATION FOR LIGHT POLE FOUNDATIONS. NOTES: DRILLED PIER 18" DIA FOR 15FT POLES 24" DIA FOR 25FT POLES JOINT FILLER AT PRMT (4) #7 @ 24" DIA, (5) #5 @ 18" DIA CHAMFER AT PRMT PITCH 9" SPIRAL 5'-0' FOR 25FT POLES 4'-0" FOR 15FT POLES 2' - 0" POLE NOTE 1 SOG WHERE OCCURS TYPICAL AT GRADE POLE FOUNDATION DRILLED PIER 18" DIA FOR 15FT POLES 24" DIA FOR 25FT POLES JOINT FILLER AT PRMT #3 SPIRALS @ 18" DIA, #4 SPIRALS @ 24" DIA (4) #7 @ 24" DIA, (5) #5 @ 18" DIA PITCH 4" SPIRAL BASE PLATE AND ANCHOR ROD NOTE 1 #3 SPIRALS @ 18" DIA, #4 SPIRALS @ 24" DIA FINISHED GRADE FINISHED GRADE NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR POLE INFORMATION AND LOCATION. 2. POLE AND BASE CONNECTION PER POLE MANUFACTURER. 3. CAST PIER DIRECTLY AGAINST UNDISTURBED EARTH. PROVIDE TEMPORARY CASING PER GEOTECHNICAL REPORT WHERE REQUIRED. 4. TOP OF FOUNDATION SHALL BE LEVEL WITH SLAB ON GRADE OR SOIL SURFACE. NOTES: 18'-0" FOR POLE #3 15'-0" FOR POLE #1 & #2 POLE, SEE NOTE 1 SOG WHERE OCCURS, SEE NOTE 4 JOINT FILLER AT PRMT AT SOG BASE PLATE AND ANCHOR BOLTS, SEE NOTES 1 & 2 1 2MAX GRADE, SEE NOTE 4 MAX 7 " (8) #9 #5 HOOPS @ 12" 48" DIA DRILLED PIER 2 1/2" MAX GROUT PAD W/ 3/8" DIA DRAIN HOLE SOG WHERE OCCURS JOINT FILLER AT PRMT AT SOG CES 4" DIA HOLE THROUGH PILE FOR CONDUIT 9" PITCH 4" PITCH 1' - 6" SEE NOTE 1 3' - 0" MIN #4 SPIRAL (4) #7NOTES: 1. PER MANUFACTURER WHERE MANUFACTURER REQUIREMENTS INDICATE A LARGER FOUNDATION. 2. CONNECTION OF CES TO FOUNDATION PER MANUFACTURER. INSTALL PER MANUFACTURER'S INSTRUCTIONS. NOTES: SEE NOTE 1 24" DIA PILE MIN R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-S-v2020.rvt 11/14/2024 11:09:03 AM BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGY403 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL TYPICAL FOUNDATION DETAILS 3LPDDJPAEISSUED FOR BID12/10/2024 SCALE: NTS TYPICAL PYLON FOUNDATION PLAN 1 - SCALE: NTS TYPICAL PYLON FOUNDATION SECTION A - SCALE: NTS TYPICAL CABINET FOUNDATION PLAN 2 - SCALE: NTS TYPICAL CABINET FOUNDATION SECTION B -SCALE: NTS TYPICAL LIGHT POLE FOUNDATION 5 - SCALE: NTS TYPICAL MAST ARM POLE FOUNDATION 3 - SCALE: NTS TYPICAL CES POLE FOUNDATION 4 - 6 ' -0" - 2 N2 OT""0 E O S - O 600 TS 0 2OE:"1 T AAS HAHN. R " - 6 2 N -.6 TF 0 S 006 15/Nov/2024 0375 RTA/CN 0205-24 HORIZONTAL JOINT AT WALLS VERTICAL JOINT VERTICAL JOINT AT AT STRUCTURAL SLABS BEAMS OR WALLS 3/4" NOTES: 1. CONSTRUCTION JOINTS ARE INTENDED TO BE MADE ROUGH EVEN THOUGH SHOWN SMOOTH IN ALL DETAILS 2. REINFORCING NOT SHOWN FOR CLARITY. HOWEVER CONTINUE ALL REINF THRU CONSTRUCTION JOINTS EXCEPT AT SLABS ON GRADE. 3. CONSTRUCTION JOINTS IN SLABS ON GRADE ARE DETAILED ELSEWHERE. .5W OR 6" MAX INTERMITTANT KEYWAY 6" LONG, 12" OC OR USE EXPANDED METAL (SEE VERTICAL JOINT AT BEAMS OR WALLS) INTERMITTENT KEYWAY 6" LONG, 12" OC W/ TAPERED SIDES SEE WALL SECTIONS AND DETAILS FOR OTHER CONDITION, WHERE INDICATED BLOCKING, THICKNESS TO SUIT COVER ON REINF. REMOVE FOR SECOND POUR EXPANDED METAL LATH, POKE REINF. THRU LATH. FORMWORK FIRST SECOND CONTINUOUS KEYWAY WITH TAPERED SIDES ALL REINF TO RUN THRU UNINTERRUPTED #4 X 3'-4" @ 16" ADDL. DELETE IF SLAB TOP BARS OCCUR CONT THRU JOINT VERTICAL JOINT AT WALLSD D/ 3 D/ 3 D/ 3 POUR POUR NOTES: DOUBLE CURTAIN AT CORNER SINGLE CURTAIN AT INTERSECTIONSINGLE CURTAIN AT CORNER TERMINATE AT 3" CLR SAME SIZE AND SPACING AS HORIZ BARS 1'-0" MIN NOTE: 1.BAR INTERSECTIONS SHOWN APPLY TO ALL SINGLE AND DOUBLE CURTAIN INTERSECTIONS AND TO ALL VARIATIONS OF VERTICAL AND HORIZONTAL REBAR POSITIONS 2.HORIZONTAL AND VERTICAL BARS PER SCHEDULE TYP. SAME SIZE AND SPACING AS HORIZ BARS 1'-6" MIN SINGLE CURTAIN AT END / ALTERNATE AT END STD 180 DEGREE HOOK 2' - 0" MIN LAP 2' - 0" MIN LAP 2' - 0" MIN LAP 2' - 0" MIN LAP (0 " ) T Y P 2' - 0 " M I N L A P 2' - 0 " M I N . L A P 2' - 0" MIN LAP STD 90 DEGREE HOOK DOUBLE CURTAIN AT INTERSECTION DOUBLE CURTAIN AT END / ALTERNATE AT END NOTES: OPEN SEE NOTE 2 SEE NOTE 1 2-#4 x 4'-0" EACH CORNER TOP AND BOTTOM IN SLAB AND EACH FACE IN WALLS NOTES : 1. HOOK ALL INTERRUPTED BARS AT FACE OF OPENING. 2. ADDITIONAL BARS EQUAL TO 1/2 REINF AREA INTERRUPTED BY OPENING SHALL BE PROVIDED EACH SIDE OF OPENING, TOP AND BOTTOM OF SLABS, MINIMUM 2 - #4 EACH FACE, OR TOP AND BOTTOM, EACH SIDE. SPACE BARS AT 3" OC. 3. FOR OPENINGS LESS THAN OR EQUAL TO 12" SQUARE IN SLABS LESS THAN 6" THICK, OR 14" SQUARE IN SLABS AND WALLS 6" OR MORE IN THICKNESS, OFFSET REINF TO CLEAR OPENING, NO ADDITIONAL REINFORCEMENT REQUIRED. 4. IF EDGE OF CONC OCCURS BEFORE INDICATED BAR EXTENSION PAST OPENING IS OBTAINED, EXTEND BAR FULL AVAILABLE LENGTH AND HOOK. 5. INDICATES SCHEDULED BARS. NOTES: LAP SPLICE AND EMBEDMENT LENGTHS BAR BARS SPACED GREATER THAN 4" BARS SPACED LESS THAN OR EQUAL TO 4" #3 14"20" #4 19"32" #5 29"46" #6 39"62" #7 55"87" #8 69"107" #9 76"116" #10 97"140" #11 120"146" NOTES: 1.PROVIDE MINIMUM LAP SPLICE LENGTHS AND EMBEDMENTS PER TABLE UNLESS NOTED OTHERWISE. EMBEDMENT LENGTH EQUALS THE LAP SPLICE LENGTH UNLESS NOTED OTHERWISE. 2.BAR SPACING AT LAP SPLICE IS THE MINIMUM CLAEAR DISTANCE BETWEEN LAPPED BARS PLUS ONE BAR DIAMETER. 3.ALL SPLICES TO BE CONTACT SPLICES AND WIRED TOGETHER UNLESS OTHERWISE APPROVED BY THE ENGINEER. NOTES: 180 DEG STD HOOK90 DEG STD HOOK CONCRETE JOINT TL 3" 5" 4 1/2" HW 4" 5" 3" 7" 8" 1'-1" 11 3/4" 8" 7" 1'-2 3/4" 1'-1 1/4" 11 1/2" 10 1/2" 6"6" HL * 8" 6" 10" Ldh BAR SIZE GRADE 60 #3 #5 #4 7" 9" 6" 1'-2" 1'-7" 1'-4" 1'-10" 2'-0" #7 #9 #8 #10 #11 15" 17" 19" 14" 12" #6 10"1'-0" * f'c = 4.5 KSID 2 1/4" 3 3/4" 3" 5 1/4" 6" 12" 10 3/4" 9 1/2" 4 1/2" COMPLYING WITH MINIMUM COVER REQUIREMENTS OF ACI 318, 12.5.3.2. OTHERWISE Ldh MUST BE RE-CALCULATED. LE N G T H Ld h DE V E L O P M E N T D T Y P * MIN COVER HL= HOOK LENGTH MI N CO V E R HW= HOOK LENGTH TL = TA I L L E N G T H R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 9 : 0 4 A M BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGY404 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL TYPICAL CONCRETE DETAILS 1LPDDJPAEISSUED FOR BID12/10/2024 SCALE: NTS TYPICAL CONSTRUCTION JOINTS 1 - SCALE: NTS TYP CONC REINFORCING AT WALL INTERSECTION/END PLANS 3 -SCALE: NTS TYPICAL CONCRETE WALL OR SLAB OPENING DETAIL 4 -SCALE: NTS CONC REINFORCING LAP AND EMBED SCHEDULE 5 - SCALE: NTS REINFORCING HOOK SCHEDULE 2 - NOTES: 1.UNLESS NOTED OTHERWISE, WALLS UP TO 10" THICK SHALL BE REINFORCED WITH A SINGLE LAYER OF #5 @ 12" EACH WAY AND WALLS UP TO 14" THICK SHALL BE REINFORCED WITH TWO LAYERS OF #4 AT 12" EACH WAY. 2.WALL DETAILS APPLY TO FOUNDATIONS AND MISCELLANIUOS CONCRETE WALLS. 3.LAP WALLS AS INDICATED IN THE SECTIONS AND DETAILS. 4.ALL VERTICAL REINFORCING IN WALLS SHALL BE CONTINUOUS FROM STRUCTURAL FOOTING/FLOOR TO STRUCTURAL FLOOR. H ORIZNI T ATRL NN Z J L W I L R HZZR WRZ TLJSNV 33O:B3B/E C O PENO O O P E N I H T A IEH UR Z R W Z ZH E O 15/Nov/2024 0376 RTA/CN 0205-24 PE R A R C H PER ARCH 4" CONC SLAB W/ #4 @ 12" EW 6" CONC WALL, ALL AROUND, W/ #4 @ 12" EW POLYSTYRENE, SEE NOTE 1 STRUC SLAB NOTES: 1.RIGID CELLULAR POLYSTYRENE WITH MINIMUM COMPRESSIVE RESISTANCE OF 7.3 PSI AT 1% DEFORMATION CONFORMING TO ASTM D6817 OR ASTM C578. 2.TYPICAL DETAIL APPLIES TO SLABS ON GRADE, TIMBER SLABS, AND SLABS ON METAL DECK. 3.PROVIDE 3/4" SAWCUT CONTROL JOINTS AT MAXIMUM SPACING OF 20 TIMES THE PAD HEIGHT EACH WAY. 4.COORDINATE WITH ARCHITECTURAL AND MECHANICAL DRAWINGS FOR BUILT-UP SLAB DIMENSIONS AND LOCATIONS. NOTIFY ENGINEER WHERE A BUILT-UP SLAB NOT INDICATED IN THE STRUCTURAL DRAWINGS IS SHOWN ELSEWHERE. NOTES: 6" MIN SLAB STRUCPAD HT AR AS REQ'D PER EQUIPMENT SUPPLIER #3 @ 12" EW FOR PAD HT UP TO 5", #4 @ 12" EW FOR PAD HT UP TO 10" NOTES: 1.TYPICAL DETAIL APPLIES TO SLABS ON GRADE, TIMBER SLABS, AND SLABS ON METAL DECK. 2.PROVIDE 3/4" SAWCUT CONTROL JOINTS AT MAXIMUM SPACING OF 20 TIMES THE PAD HEIGHT EACH WAY. 3.COORDINATE WITH ARCHITECTURAL AND MECHANICAL DRAWINGS FOR HOUSEKEEPING PAD DIMENSIONS AND LOCATIONS. NOTIFY ENGINEER WHERE A PAD NOT INDICATED IN THE STRUCTURAL DRAWINGS IS SHOWN ELSEWHERE. NOTES: "D ""D ""D " 'D ' "d" BAR DIAMETER 1 6 MAX SLOPE "D" = BAR BEND DIAMETER 6d FOR #3 THRU #8 8d FOR #9, #10, AND #11 NOTE: CAP STIRRUPS MAY BE USED IN BEAMS UNO 135 DEG BEND "d" BAR DIAMETER ALTERNATE CAP DIRECTION IF SLAB OCCURS BOTH SIDES OF BEAM OR LOCATE 90 DEG BEND TYP ON SLAB SIDE WHERE SLAB OCCURS ONLY ONE SIDE. IF NO SLAB OCCURS EITHER SIDE PROVIDE 135 DEG. BEND ON EACH SIDE. 90 DEG BEND 135 DEG BEND, TYP CAP STIRRUP WIRE REINFORCING TOGETHER -TYP SPLICE PER SCHEDULE NOTE: ALL HOOKS, BENDS, AND LAPS SHALL BE AS INDICATED UNO 2 1/2" MIN 4d 6" MIN 12d 3" MIN 6d . R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-S-v2020.rvt 11/14/2024 11:09:05 AM BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGY405 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL TYPICAL CONCRETE DETAILS 2LPDDJPAEISSUED FOR BID12/10/2024 SCALE: NTS TYPICAL BUILT-UP SLAB ON POLYSTYRENE DETAIL 1 - SCALE: NTS TYPICAL HOUSEKEEPING PAD 3 - SCALE: NTS TYP CONC REINFORCING DETAILS 2 - P ER AC H 4HR"OCC A N " S " R PAAROSRA H"N L CB O NN: GNGOW/ RPNTRE S A L OR I A E F R PN C P H4 WP O#R A R S A AP G F N GFR 15/Nov/2024 0377 RTA/CN 0205-24 PLAN ELEVATION NOTES: 1.TIGHTEN ANCHOR RODS SNUG TIGHT AND SCORE ANCHOR ROD THREADS TO PREVENT LOOSENING. 2.CONTRACTOR SHALL HOLD BASE PLATE RIGIDLY IN PLACE WHILE GROUTING. 3.FINISH COLUMN END AND BASE PLATE PER AISC REQUIREMENTS. 1/4 10" 10 " 1" TYP 1" T Y P 1/2" DIA ANCHOR RODS W/ 4" EMBED AND STD PL WASHERS BASE PL 5/16 ASTM F1554 GR 36 ANCHOR ROD W/ STD PL WASHER AND NUTS BOTH ENDS STL COL GR O U T 1 1 / 2 " N O N - S H R I N K OVERSIZED HOLE IN BASE PL, TYP NOTES: 1 1/2" TYP 2" TYP BM GAGE WORKABLE 1/4 (4) 7/8" DIA BOLTS HSS POST SUPPORT BEAMSTIFF PL 3/8 ES FIT TO BEAR 3/16 3/16 (3) SIDES, TYP PLAN ELEVATION NOTES: 1. REFER TO BASE PLATE DETAILS FOR MORE INFORMATION. 2. HOOK REINFORCING WHERE IT CANNOT CONTINUE DUE TO PILE CAP EDGE. 3. WHEN THE EDGE OF THE RECESS IS WITHIN 6 INCHES OR LESS TO THE PILE CAP EDGE, ACCEPTABLE TO EXTEND RECESS TO PILE CAP EDGE. NOTES: COL INFILL AFTER COL ERECTION WHERE TOP REINF IS INTERRUPTED AT RECESS, MATCH SIZE AND QUANTITY OF INTERRUPTED BARS EACH WAY BELOW RECESS, SEE NOTE 2 GROUT ANCHOR 4" BASE PL 1 1/2" TYP GUSSET PL AS OCCURS SECTIONPLAN #4 TYP 2'-0" MIN HOOK REINF WHERE INTERRUPTED PC1 AS OCCURS 1 2 " T Y P SOG R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-S-v2020.rvt 11/14/2024 11:09:06 AM BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGY406 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL TYPICAL STEEL COLUMN DETAILSLPDDJPAE ISSUED FOR BID12/10/2024 SCALE: NTS TYPICAL GRAVITY BASE PLATE DETAIL 1 -SCALE: NTS TYPICAL HSS POST ON WF BEAM DETAIL 2 - SCALE: NTS TYPICAL BASE PLATE RECESS AT CORE FACILITY 3 - P LANEVNT ITAOSVV E : O C N O A PEEASCAE TO:R VD S NN:G2N2O B V N P T I N P SUA E A C E EP 15/Nov/2024 0378 RTA/CN 0205-24 SEE SCHEDULE A FOR QUANTITY, SIZE AND TYPE OF BOLTS SHEAR PLATE, SEE SCHEDULE A FOR PLATE THICKNESS COLUMN FLANGE, NEAR SIDE CUT AWAY FOR CLARITY A A SEE SCHEDULE A FOR PLATE THICKNESS AND WELD SIZE BEAM, SEE PLAN 1/2" NOTES: 1. USE AISC STD HOLES OR SHORT HORIZ. SLOTTED HOLES IN SHEAR PLATE (HARDENED WASHERS REQD WITH SLOTTED HOLES). NOTE:PROVIDE 1/2" CAP PLATE (NOT SHOWN) AT TOP OF COLUMN 5/16 PL TO COLUMN FLANGE PL 1/2", TYP (OMIT TOP PLATE WHERE CAP PLATE OCCURS AT ROOF 2"1 1/2" 1 1 / 2 " N @ 3 " 1 1 / 2 " NOTES: BEAM, SEE PLAN FITTED STIFFENER, SEE BEAM CONNECTION SCHEDULE 1/2" COLUMN CAP PLATE WITH 4-7/8" DIA. BOLTS COLUMN 1/4 1/2" COLUMN CAP PLATE WITH 4-7/8" DIA. BOLTS BEAM, SEE PLAN COLUMN 1/4 TRANSVERSE BEAM, SEE NOTE 1 TRANSVERSE BEAM, SEE NOTE 1 COLUMN ALIGNED WITH BEAM COLUMN TRANSVERSE WITH BEAM 1 1/2" NOTES: 1.WHERE TRANSVERSE BEAM IS NOT SHOWN ON PLAN, ADD A W12X35. NOTES:SEE SCHEDULE A FOR QUANTITY, SIZE AND TYPE OF BOLTS NOTES: 1. THIS DIMENSION SHALL BE FOR STD SIZED HOLES. WHERE SHORT SLOTTED HOLES ARE USED, INCREASE DIMENSION TO 1-3/4". 2. MINIMUM DISTANCE FROM TOP BOLT TO TOP OF COPE SHALL BE 1-1/2". 3. USE AISC STD. HOLES OR SHORT HORIZ. SLOTTED HOLES IN SHEAR PLATE (HARDENED WASHERS REQD WITH SLOTTED HOLES). 4. PROVIDE FITTED SHEAR PLATE AS SHOWN AT ALL ONE-SIDED CONNECTIONS, PERIMETER BEAMS AND ALL CONNECTIONS WITH BEAMS AND GIRDER OF SAME NOMINAL DEPTH. 5. AT PERIMETER SPANDREL BEAMS, PROVIDE FITTED SHEAR PLATES ON BOTH SIDES OF GIRDER. SHEAR PLATES SHALL EXTEND TO GIRDER BOTTOM FLANGE AS SHOWN. 6. CONNECTION AT SKEWED BEAMS SIMILAR. 2"(NOTE 1) 1 1/2" 1/2" FITTED SHEAR PLATE (SEE NOTES 4 & 5)SHEAR PLATE, SEE SCHEDULE A FOR THICKNESS A A SEE SCHEDULE A FOR PLATE THICKNESS AND WELD SIZE 3/16" MAX. G A+G WHERE G EXCEEDS 3/16", BEVEL PL END PL THK THK-1/8 A PJP SKEWED BEAM CONNECTIONSLESS THAN 30° 30°-60° BM, SEE PLAN 1 1/2"2" BEAM WEB FOR ANY SKEW ANGLE BEAM WEB BEAM WEB 1 1/2" N @ 3" NOTE 2 1 1/2" NOTES: 1/2" A A SEE SCHEDULE A FOR PLATE THICKNESS AND WELD SIZE SEE SCHEDULE A FOR QUANTITY, SIZE AND TYPE OF BOLTS NOTES: 1. USE AISC STD HOLES OR SHORT HORIZ. SLOTTED HOLES IN SHEAR PLATE (HARDENED WASHERS REQD WITH SLOTTED HOLES). 2. DETAIL APPLIES TO HSS COLUMNS AS WELL. 1/4 1/2" CAP PLATE AT TOP OF COLUMN BEAM, SEE PLAN COLUMN SHEAR PLATE, SEE SCHEDULE A FOR THICKNESS 2" 1 1/2" 1 1/2" N @ 3" 1 1/2" NOTES: SEE SCHEDULE A FOR QUANTITY, SIZE AND TYPE OF BOLTS SHEAR PLATE, SEE SCHEDULE A FOR PLATE THICKNESS COLUMN FLANGE, NEAR SIDE CUT AWAY FOR CLARITY COPE BEAM FOR CLEARANCE IF REQD A A SEE SCHEDULE A FOR PLATE THICKNESS AND WELD SIZE COLUMN BEAM, SEE PLAN 1/2" NOTES: 1. USE AISC STD HOLES OR SHORT HORIZ. SLOTTED HOLES IN SHEAR PLATE (HARDENED WASHERS REQD WITH SLOTTED HOLES). 2"1 1/2" 1 1/2" N @ 3" 1 1/2" NOTES: CJP TOP & BOT FLANGE, TYP SEE SCHEDULE C FOR PLATE THICKNESS AND WELD SIZE BEAM, SEE PLAN COLUMN FITTED COLUMN STIFFENERS, TOP & BOTTOM, ALIGN WITH FLANGES OF BEAMS SHEAR PL TO TOP & BOT PL, COL WEB SEE SCHEDULE C FOR NUMBER, SIZE AND TYPE OF BOLTS SHEAR PLATE SEE SCHEDULE C 3/4"1 1/2" 3" R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-S-v2020.rvt 11/14/2024 11:09:08 AM NTS BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGY407 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL TYPICAL STEEL BEAM DETAILS 1LPDDJPAEISSUED FOR BID12/10/2024 SCALE: NTS BEAM TO COLUMN WEB CONNECTION (EXTENDED SHEAR PLATE)1 - SCALE: 1" = 1'-0" BEAM OVER COLUMN CONNECTION 6 -SCALE: NTS BEAM TO GIRDER CONNECTION 5 - SCALE: NTS BEAM TO COLUMN FLANGE CONNECTION (SHEAR PLATE)2 -SCALE: NTS BEAM TO COLUMN WEB CONNECTION (SHEAR PLATE)3 - SCALE: NTS BEAM TO COLUMN WEB MOMENT CONNECTION 4 - S E CHDCU LU AFDD H O A R C A SHH FR H UAOQDN F NNSMKNKOTI 1 / 2 " " 1 / D C S UL CTS FY H R H HS / 15/Nov/2024 0379 RTA/CN 0205-24 GIRDER SIZE VARIES, SEE PLAN BEAM DEPTH LESS THAN GIRDER DEPTH BEAM DEPTH EQUALS GIRDER DEPTH TYP BM TO GIRDER CONNECTION N:1 N:1 SEE WELD NOTE 1 WELD NOTES: 1. WELD SIZE = 1/2 PLATE THICKNESS (MIN 5/16" FOR GRADE 50 STEEL) 2. PLATE THICKNESS = BEAM FLANGE THICKNESS + 1/4" PLATE WIDTH = BEAM FLANGE WIDTH -1" GRADE SHALL MATCH BEAM NOTE 1 WELD NOTE 2 1/4 2/3 BEAM DEPTH FOR W18 AND LARGER. BEAM DEPTH FOR W16 AND SMALLER (12" MINIMUM) CJP . BM MAY SLOPE PER PLAN NOTES: 1.WHERE BEAM SLOPES, IN LIEU OF PROVIDING TOP PLATE, PROVIDE PLATES PER DETAIL "AT SLOPING BEAM". NOTES: SEE WELD NOTE 1 ADDL PLS TO MATCH BM FLG WIDTH AND THK + 1/4" CJP TYP AT SLOPING BEAM GIRDER FITTED COLUMN STIFFENERS, TOP & BOTTOM, ALIGN WITH FLANGES OF BEAMS. PLATE THICKNESS = BEAM FLANGE PLUS 1/4", TYP CJP TOP & BOT FLANGE, TYP NOTE: 1.WHERE FRAMING MEMBERS ARE DIFFERENT NOMINAL SIZES, FITTED STIFFENER SHALL BE SLOPED TO ALIGN WITH FLANGES. SEE SCHEDULE C FOR NUMBER, SIZE AND TYPE OF BOLTS C C SEE SCHEDULE C FOR PLATE THICKNESS AND WELD SIZE BEAM, SEE PLAN COLUMN SHEAR PLATE SEE SCHEDULE C NOTE: 1. ALL FIELD BOLTED CONNECTIONS SHALL BE MADE WITH 7/8" DIAMETER BOLTS, UNO. 2. BOLT SIZE AND NUMBER SHALL BE TYPICAL FOR ALL CONDITIONS, UNLESS DETAILED OTHERWISE. ALL BOLTS SHALL BE A325 BOLTS. 3. ALL BEAM TO COLUMN, CANTILEVER BEAM AND COLLECTOR BEAM CONNECTIONS SHALL BE SLIP-CRITICAL (SC) BOLTS. SEE STRUCTURAL NOTES. 4. PLATES SHALL HAVE Fy = 50 KSI MINIMUM. SCHEDULE A BEAM SIZE PLATE THICKNESS WELD SIZE "A"NUMBER OF BOLTS W8 5/16"1/4"2 W10 5/16"1/4"2 W12 3/8"5/16"3 W14 W16 W18 W21 W24 W27 W30 W33 W36 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 7/16" 7/16" 1/2" 5/16" 5/16" 5/16" 5/16" 5/16" 5/16" 3/8" 3/8" 7/16" 3 4 5 6 6 7 8 9 10 SCHEDULE C -SHEAR PLATES AT MOMENT CONNECTIONS BEAM SIZE PLATE THICKNESS WELD SIZE "C"NUMBER OF BOLTS W12 3/8"5/16"3 W14 W16 W18 W21 W24 W27 W30 3/8" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 5/16" 5/16" 5/16" 5/16" 5/16" 3/8" 3/8" 3 4 5 6 7 14 (2 VERT ROWS) 16 (2 VERT ROWS) W10 5/16"3/16"2 BEAM, SEE PLAN BEAM, SEE PLAN BRACE, L3X3X1/4 TYP (FOR LENGTHS GREATER THAN 10' USE L4X4X1/4 UNO) SEE PLAN FOR LOCATION PL 3/8 LENGTH 3/16 TYP INDICATES DIRECTION OF BRACE CONNECTION TO THE BOTTOM OF BEAM BEAM, SEE PLAN 3/16 (3) SIDES TYP EE PL 3/8 PL DETAIL NOTES: 1. PROVIDE A 3/16" CAP PLATE AT ALL BEAMS UNLESS NOTED OTHERWISE. NOTES: 1/ 4 " A L L A R O U N D 1 1 / 2 " 2" 1 1 / 2 " 1"1 1/2" 5" 2 1/2"(2) 5/8" DIA BOLT 3/16 3/16 3/16 BM BM BM END WHERE OCCURS BM WHERE OCCURS (2) PL 1/4, SEE DET'L PL 1/4 NOTES: 1.FOR RECTANGULAR OPENINGS, THE RADIUS OF THE CORNER SHALL BE THE LARGER OF AT LEAST TWICE THE WEB THICKNESS OR 1/2-INCH. 2.FOR FIELD CUT PENETRATIONS REQUIRING REINFORCING, INSTALL REINFORCING PLATES PRIOR TO CUTTING BEAM WEB PENETRATION. 3.CONTRACTOR TO DETAIL CONDUIT IN CONJUNCTION WITH BEAM WEB PENETRATIONS AND ARCHITECTURAL ITEMS. L-A CL PEN CL P E N L-B BM D E P T H PLAN SEE PL 'A', NS & FS PL 'B' WF OR HSS BM D I A OPNG BXH OR DIA, SEE NOTE 1 TYP BEAM WEB PENETRATION SCHEDULE OPNG PLATES 'A'PLATE 'B' REMARKSTxBxL-A TxBxL-BWELD WELD 4.5" X 2" NOTES: H B MARK A 3" X 2"B BARE OPENING BARE OPENING R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-S-v2020.rvt 11/14/2024 11:09:10 AM BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGY408 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL TYPICAL STEEL BEAM DETAILS 2LPDDJPAEISSUED FOR BID12/10/2024 SCALE: NTS CANTILEVER BEAM MOMENT CONNECTION 1 -SCALE: NTS BEAM TO COLUMN FLANGE MOMENT CONNECTION 2 - SCALE: NTS STANDARD BEAM CONNECTION SCHEDULES 4 -SCALE: NTS STANDARD BEAM CONNECTION SCHEDULES 5 -SCALE: NTS TYPICAL BOTTOM FLANGE BRACE CONNECTION 6 - SCALE: NTS TYPICAL HSS BEAM TO HSS BEAM SHEAR CONNECTION 3 - SCALE: NTS TYPICAL BEAM WEB PENETRATION 7 - G IRDE DS ZSRVA E , V P D V R GEERAPRE SV,L N A .. . B M NOTENS : A LN P A S I N OT D G SZ DBG ATR E R P E EG G I T GIN 15/Nov/2024 0380 RTA/CN 0205-24 PL1/2 1/4 1/4 1 1 / 2 " 3" 3" 2" MAX 6" CONN PER TYP DTS SEE TABLE A PL3/4X4 CJP 1/4 1/4TYP STIFF PL5/16 ES 1" SHIM AS REQD 1/4 1/4 (3) SIDES TYP MIN 1/4" (4) 78" DIA A325 BOLTS @ BM GAGE PL3/8 ES SLOPING BM GIRDER PL3/8 ES NOTE 1 1/4 1/4 (3) SIDES TYP 1/4 CAP PL1 NOTE 2 HSS COL MIN 2"TYP 2" NOTES: 1.WHERE BEAM FRAMES INTO PLATE, PROVIDE A FULL HEIGHT PLATE. 2.CAP PLATE WIDTH TO EXTEND HALF AN INCH EITHER SIDE OF COLUMN OR BEAM FLANGE. WHICHEVER IS GREATER. NOTES: PL3/8 ES NOTE 1 1/4 1/4 (3) SIDES TYP 1/4 CAP PL1 NOTE 2 HSS COL AT TAPERED BEAM TYP 1" 5/16 NS,FS 1/4 1/4 3" TYP 1/2" TYP ROOF DECK SUPT BM, WHERE OCCURS BM, WHERE OCCURS 6" @ W18 OR LARGER 4" @ W16 OR SMALLER MATCH WEB THK TO LOWERED BM STIFF PL1/4 ES @ 3'-0" LOWERED BM CL WT & WFWT, TRIM TO FIT (3) SIDES TYP NOTES: 1. DECK MAY SPAN EITHER DIRECTION. 2. DO NOT CONNECT WT TO ANYTHING OTHER THAN LOWERED BEAM AND ROOF DECK. NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-S-v2020.rvt 11/14/2024 11:09:11 AM 1" = 1'-0" BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGY409 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL TYPICAL STEEL BEAM DETAILS 3LPDDJPAE ISSUED FOR BID12/10/2024 SCALE: 1" = 1'-0" TYPICAL CONNECTION DETAIL AT LOWERED BEAM 3 -SCALE: 1" = 1'-0" TYPICAL BEAM OVER BELOW GIRDER 2 -SCALE: 1" = 1'-0" WIDE FLANGE OVER HSS COLUMN DETAIL 1 - SCALE: 1" = 1'-0" TYPICAL DECK SUPPORT AT LOWERED BEAM 4 - (4) 7/8" DIA A325 BOLTS @ BM GAGE P L1/24/ " 13M442 A 3 X / 3 1 P221MX12 3 A 6 4C M O N NOTENS : A PN R A S D N OT 4 / P " /OP ME1 2 1 X 22P B D T BDN 15/Nov/2024 0381 RTA/CN 0205-24 36/7 ATTACH WITH 5/8" DIA PUDDLE WELDS AT 8" OC MIN ALONG PERIMETER STEEL SUPPORTS PARALLEL TO DECK SPAN DECK LEN G TH -3 SPA NS MIN ATTACH WITH 5/8" DIA PUDDLE WELDS AT 8" OC TO PERIMETER STEEL SUPPORT PERPENDICULAR TO DECK SPAN SIDE LAP CONNECTIONS EQUALLY SPACED, SEE PLAN FOR CONNECTION PATTERN 36/4 ATTACH TO INTERMEDIATE SUPPORTS NOTES: 1. PROVIDE WELDS AT DECK END LAPS THAT SUFFICIENTLY PENETRATE BOTH LAYERS OF DECK. 2. DECK FASTENING REQUIREMENTS SHALL NOT BE LESS THAN AS SHOWN ON PLANS AND DETAILS OR PER MANUFACTURER'S RECOMMENDATIONS END LAP PER MANUFACTURER'S REQUIREMENTS BUT NOT LESS THAN 2" DECK WHERE OCCURS AT INTERIOR INTERIOR OR PERIMETER BEAM CONNECTION PARALLEL TO FLUTES CONNECTION PERPENDICULAR TO FLUTES INTERIOR OR PERIMETER BEAM 2" MIN LAP DECK WHERE OCCURS AT INTERIOR TOP SEAM WELD (TSW) DETAIL 1 1/2" LONG TSW SHALL ENGAGE TOP OF INNER LEG @ 8" OC CRIMP LEGS TOGETHER PRIOR TO WELDING ALTERNATE SEAM CONN DETAIL DELTA GRIP (ESR-1414) DELTA GRIP @ 18" OC DECK THK MIN OFFSET ≤ 20 GA 0.19" >20 GA 0.16" PER SCHED MIN OFFSET NOTES:NOTES: BEAM STEEL ROOF DECK SEE PLAN FOR ORIENTATIONMIN 2" CONT BENT PL 1/4, SEE NOTE 1CLADDING WHERE OCCURS SEE ARCH EXTERIOR WALL CONNECTION DESIGNED, PROVIDED AND INSTALLED BY EXTERIOR WALL SUPPLIER NOTES: 1.WHERE EXTERIOR WALL CONNECTION DOES NOT EXIST, ACCEPTABLE TO REDUCE BENT PLATE TO 3/16" 3/16 3-12 3/16 3-12 CL BM AS R E Q D 4" MA X MAX 18" NOTES: COVERED BY FLAT SHEET (2) MIN UNINTERRUPTED RIBS TO BE MI N 1' - 0 " MA X 1' - 0 " MI N 1' - 0 " DE C K S P A N MAX 12" 1/8 1 1/8 1-8 ONE PIECE 16 GAGE FLAT METAL REINF AROUND OPENING PLACED ON BOT OF DECK THEN WELDED TO BOTH INTERRUPTED AND UNINTERRUPTED RIBS. DECK AT EA RIB NS & FS (3) WELDS MIN NS & FS NOTES: 1.DETAIL DOES NOT APPLY WHEN SUPPORT BEAM IS ANY OTHER PROFILE THAN HSS. 2. LOAD MAY OCCUR IN ANY DIRECTION. CONNECTION HAS BEEN DESIGNED FOR AN ALLOWABLE 3,000 POUND LOAD. NOTES: CL BM 2' - 0 " M A X PE R A R C H PL1/2 X 4 W/ 2" DIA HOLE CENTERED ON PL AND PERP TO DIRECTION OF FALL ARREST CABLE ROOF DECK CAP PL3/4X4X4 HSS3X3X3/8 1/4T&B HSS SUPPORT BM 1/4 1/4 LOAD NOTE 2 NOTES: 1.METAL DECK WELDING PER STANDARD DETAILS. NOTES: CL BM 3/16 4-12 3/16 4-12 METAL ROOF DECK BENT PL 1/4" CONT 2" M A X TOS ELEV 1" TYP R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 9 : 1 2 A M BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGY410 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL TYPICAL ROOF DECK DETAILS 1LPDDJPAEISSUED FOR BID12/10/2024 SCALE: NTS ROOF DECK CONNECTION DETAIL 1 -SCALE: NTS EXTERIOR SLAB EDGE DETAIL AT ROOF DECK 2 - SCALE: NTS ROOF DECK OPENING DETAIL 3 -SCALE: NTS TYPICAL FALL ARREST POST 4 -SCALE: NTS TYPICAL METAL DECK CONNECTION DETAIL 5 - 3 6/7 A7T CT/HWAA I H 5 7 H / 3 /W5/ THI8A" W CCIR-C-OD P A 7 3 T C 7D3 WU/ /5 3 15/Nov/2024 0382 RTA/CN 0205-24 WP CL COL CL BM STL BM PER ELEV, BM TO COL CONNECTION PER STD DETAILS STL COL PER ELEV PL 1/4 CAP SEAL WELD ALL AROUND 1 " T Y P1 1 / 2 " 3" 1 1 / 2 " 2"1 1/2" 1" MIN 1/4 1/4GUSSET PL THK PER SCHED PL 3/8 W/ (2) 7/8" DIA BOLTS CAP PL 5/8 1/4 1/4 1/4 PL 5/16 W/ (2) 7/8" DIA BOLTS STL BRACE PER ELEV FULL DEPTH PJP, T&B 1 " 1 1/2" 4" 1 1/2" 1" M I N 1/2" PER SCHED LA PER SCHED LB CL COLCL HSSWP STL COL PER ELEV 1/4 1/4 GUSSET PL THK PER SCHED PL 3/8 W/ (2) 7/8" DIA BOLTS PL 5/8 1/4 1/4 1/4 PL 5/16 W/ (2) 7/8" DIA BOLTS STL BRACE PER ELEV PER SCHED LB 1" 1 1/2" 3" 1 1/2" 1" T Y P 1 1/2" 3" 1 1/2" 1 1/2" BASE PL 3/4 X 13 W/ (6) 3/4" DIA ANCHORS @ 9 1/2" W/ 9" EMBED 1/2 " T YP PER SCHED LA 1/2" (2) EQ SPCS 1 3/4" TYP MATCH WASHER SIZE, TYP 3/16 TYP @ WASHER 6 1/2" 1" MIN 1/4 WP MIDSPAN OF BM CL BM 1" M I N 1" T Y P PER SCHED LB PER SCHED LA 1 1/2" 4 " 1 1/2 "1" 1 1/2" 3" 1 1/2" CL SYM STL BM PER ELEV STL BRACE PER ELEV 1/4 CAP PL 1 PL 5/8 W/ (4) 1" DIA BOLTS PL 1/2 STIFF, NS & FS 1/4 1/4 NS,FS 1/2" TYP CL COLCL HSSWP STL COL PER ELEV 1/4 1/4 GUSSET PL THK PER SCHED PL 7/8 W/ (4) 7/8" DIA BOLTS PL 7/8 1/4 1/4 1/4 PL 7/8 W/ (3) 7/8" DIA BOLTS STL BRACE PER ELEV PER SCHED LA 1/2" 1" 1 1/2" 3" 1 1/2" 1 1/2"3" 3" 1 1/2" 1 1/2" 1 1/2 " 3 " 1 1/2 " PER SCHED LB BASE PL 3/4 X 13 W/ (10) 7/8" DIA ANCHORS @ 9 1/2" W/ 9" EMBED (4) #4 x (4) #4 x T Y P1/2 " 3'-0" 3'-0" 2'-6"2'-6" MATCH WASHER SIZE, TYP 3/16 TYP @ WASHER (4) EQ SPCS 1 3/4" TYP 6 1/2" 1" MIN 1/2 1" T Y P CONNECTION SCHEDULE CONNECTION TC1 LA (IN)LB (IN)GUSSET PLATE THICKNESS (IN) APPLICABLE DETAIL 14.5 9.5 1/2 1/BT120-SGY411 BC2 12 14.5 1/2 4/BT120-SGY411 TC3 12.5 10.5 1/2 1/BT120-SGY411 TC5 17 10 1/2 1/BT120-SGY411 BC6 12 13.5 1/2 4/BT120-SGY411 TC7 16 11 1 2/BT120-SGY411 BC8 13 14.5 1 5/BT120-SGY411 TC9 14 12 1 2/BT120-SGY411 BC10 13 17 1 5/BT120-SGY411 TC11 21 11 1 3/BT120-SGY411 BC12 13 17 1 5/BT120-SGY411 BC13 12 16.5 1/2 4/BT120-SGY412 BC14 13 17 1 5/BT120-SGY412 1/4 1/4 1/2" PER SCHED LA PER SCHED LB 1 1/2" 3" 3" 1 1/2" 1" 2" 1 1/2" MIN 1" 1" 1 1/2" 4" 1 1/2" PL 5/16 W/ (3) 7/8" DIA BOLTS STL COL STL BM SLOPE PER PLAN STL BRACE PL 7/8 W/ (4) 7/8" DIA BOLTS PL 3/4 CAP PL1/2 GUSSET PL PER SCHED 1/4 1/4 1/4 1/4 1/4 1/4 TAPER WHERE OCCURS T Y P1 1/2" 3" WP 1/2" MIN1" 1" T Y P CL BM R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-S-v2020.rvt 11/14/2024 11:09:15 AM BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGY411 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL TYPICAL BRACED AND MOMENT FRAME DETAILS 1LPDDJPAEISSUED FOR BID12/10/2024 SCALE: NTS BRACE FRAME TOP DETAIL 1 - SCALE: NTS BRACE FRAME BOTTOM DETAIL 4 - SCALE: NTS BRACE FRAME CENTRAL DETAIL 3 - SCALE: NTS BRACE FRAME BOTTOM DETAIL 5 -SCALE: NTS STEEL BRACE FRAME CONNECTION SCHEDULE 6 - SCALE: NTS BRACE FRAME DETAIL 2 - W PCL OLB MBCSTOO E S R L S C W CTRC BSEVO, T NI WP W W W P O L W BM LNW TDC C R W W 15/Nov/2024 0383 RTA/CN 0205-24 1/4 1/4 TYP HSS MF COL ELEVATION PLAN 1/4 (3) SIDES, TYP WT8X50X0'-4 1/2" 2" 1/4 1/2" TYP STL MF BM PL 7/8 7" T Y P 4" TYP (2) BOLT CONN PER TYP DTS NOTES: 1. WHERE BEAM SLOPES, SLOPE TOP CONNECTION PLATE TO MATCH AND SUBSTITUTE WT WITH TWO PLATES THAT MATCH THICKNESS AND WIDTHS OF FLANGE AND WEB. WELD WEB PLATE TO FLANGE PLATE WITH A DOUBLE SIDED 5/16-INCH FILLET WELD. NOTES: BF BM ADDITIONAL BOLTS TO MATCH TABLE A FOR BF BM BF COL FULL HT CONN PER TYP DTS, NUMBER OF BOLTS PER TABLE A FOR CORNER BM STIFF PL PER TYP DTS INCOMING BM NOT SHOWN FOR CLARITY CORNER BM FULL DEPTH PJP, T&B CL COLCL HSSWP STL COL PER ELEV 1/4 1/4 GUSSET PL THK PER SCHED PL 3/8 W/ (2) 7/8" DIA BOLTS CAP PL 5/8 1/4 1/4 1/4 PL 5/16 W/ (2) 7/8" DIA BOLTS STL BRACE PER ELEV PER SCHED LA 1/2" 1" 1 1/2" 3" 1 1/2" 1 1 / 2 " 3" 1 1 / 2 " MIN 1" 1 1/2" BASE PL 3/4 W/ (8) 3/4" DIA ANCHORS W/ 9" EMBED 1/2" TY P 6 1/2" 1' - 1" CL COL 6 1 / 2 " 1' - 1 " CL C O L 1 3/4" TYP 1 3 / 4 " T Y P MATCH WASHER SIZE, TYP 3/16 TYP @ WASHER 1" TYP PER SCHED LB 1/4 CL COLCL HSSWP STL COL PER ELEV 1/4 1/4 GUSSET PL THK PER SCHED PL 7/8 W/ (4) 7/8" DIA BOLTS CAP PL 5/8 1/4 1/4 1/4 PL 7/8 W/ (3) 7/8" DIA BOLTS STL BRACE PER ELEV PER SCHED LA 1/2" 1" 1 1/2" 3" 1 1/2" 1 1/2" 3" 3" MIN 1" 1 1/2" BASE PL 3/4 W/ (14) 7/8" DIA ANCHORS W/ 9" EMBED 6 1/2" 1' - 1" CL COL 6 1/2"1' - 1" CL C O L 1 3/4" TYP 1 3/4" TYP (2) EQ SPACES (2) EQ SPACES (4) #4 3'-0" 3'-0" (4) #4 2'-6" 2'-6" MATCH WASHER SIZE, TYP 3/16 TYP @ WASHER 1 1/2 " 3 " 1 1/2"T Y P1/2" PER SCHED LB 1 1/2"3/8 EA GUSSET EA GUSSET 1" T Y P R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-S-v2020.rvt 6/2/2025 11:28:44 AM BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGY412 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL TYPICAL BRACED AND MOMENT FRAME DETAILS 2LPDDJPAE LPD AJF AE 12/10/2024 384ISSUED FOR BID SCALE: NTS MOMENT FRAME DETAIL 1 -SCALE: 1" = 1'-0" BRACED FRAME BEAM CONNECTION 3 - SCALE: NTS BRACE FRAME BOTTOM DETAIL 4 -SCALE: NTS BRACE FRAME BOTTOM DETAIL 5 - 1 1 06/13/2025 ADDENDUM #1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 1 /4TYPTH SH4 MPP Y F C T 4 1YY4MC4Y H F O PL M STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 1' - 8" 1' - 8 " COL BASE PL 1 1/2 (t-1/8)PJP COL 1 1 / 2 " N O N - S H R I N K G R O U T ELEVATION PLAN 2 1/2"5"5"5"2 1/2" 2 1 / 2 " 5" 5" 5" 2 1 / 2 " (12) 1 1/4" DIA AR @ CANOPY W/ 12" EMBED t MATCH WASHER SIZE, TYP 3/16 TYP AT WASHER NOTES: 1.TOP AND BOTTOM PLATES AND THEIR WELDS FOR MOMENT CONNECTION ARE TO BE INSTALLED AT CANTILEVER CONDITION ONLY. 2.METAL DECK AND CHANNEL NOT SHOWN FOR CLARITY. SEE DETAIL 4/ BT120 SGD112 FOR METAL DECK AND CHANNEL AT BOTTOM INTERIOR BEAM. 8 " 1 1 / 2 " 3" 1 1 / 2 " 1/4" GAP 1 1/2" 1 1 / 2 " 4" 3 1 / 2 " 1/2" GAP 1 1/2" 1 1/2" CL SYM, UNO PL3/8X4X0'-6" T&B SEE NOTE 1 PL1/2X9X1'-5" W/ (4) 5/8" DIA BOLTS L3X3X1/4 ES OF COL L3X3X1/4 W/ (2) 5/8" DIA BOLTS 1/4 1/4 TYP 1/4 (3) SIDES, TYP 1/4 (3) SIDES, TYP 1/4 (3) SIDES, TYP WP CO L BM BM CL BM CL BM SEE NOTE 1 CO L NOTES:5/16 5/16COL T PL CL SYM, UNO CL BM 1 1/2"3 1/2"1 1/2" 1 1 / 2 " 4" 1 1 / 2 " 9 1/4" 1/2" GAP CL GAP & PL PL1/4 ES (4) 5/8" DIA BOLTS PL1/4X7X1'-0" 1/4 (3) SIDES 1/4 1/4 1" 1 1 / 2 " PL1/2 W/ HOLE FOR 1 1/2" DIA CLEVIS PIN 9" 2 3/4" PL5/16X4X0'-10" T&B ES, SEE NOTE 1 NOTES: 1.TOP AND BOTTOM PLATES AND THEIR WELDS FOR MOMENT CONNECTION ARE TO BE INSTALLED AT CANTILEVER CONDITION ONLY. 2.METAL DECK NOT SHOWN FOR CLARITY. SEE DETAIL 4/ BT120-SGD112 FOR METAL DECK AT EDGE BEAM. 1/4 1/4 (3) SIDES, TYP 1/4 1/4 NS & FS BM BM (1/4) SEE NOTE 1 NOTES: SEE NOTE 1 #5 CLEVIS PIN HSS12X6X1/4 GRID NOTES: 1.TOP AND BOTTOM PLATES AND THEIR WELDS FOR MOMENT CONNECTION ARE TO BE INSTALLED AT CANTILEVER CONDITION ONLY. PL3/8X4X0'-6" T&B SEE NOTE 1 1/4 1/4 TYP 1/4 (3) SIDES, TYP CL SYM, UNO CL BM WP 3 1 / 2 " 1 1 / 2 " 3" 1 1 / 2 " 1/4" GAP 1 1/2" SEE NOTE 1 L2 1/2X2 1/2X1/4 ES OF COL 1/4 (3) SIDES, TYP CL BM BM 1 1/2" 1 1/2" 1/2" GAP 1 1 / 2 " 4" 3 1 / 2 " PL1/2X9X1'-5" W/ (4) 5/8" DIA BOLTS L3X3X1/4 W/ (2) 5/8" DIA BOLTS 1/4(3) SIDES CO L BM CO L NOTES: 5/16 5/16 COL TO PL 2' - 4 1 / 2 " 3 1 / 2 " 3" TYP T Y P2 1/2" PL 1/2 W/ HOLE FOR 1 1/2" DIA CLEVIS PIN, TYP 1" T Y P CL COL CL COL PL1/2X 6 1/2X 0'-11", TYP 1/4TYP 1/4 1/4 TYP WP PL3/8 CAP, SEAL WELD ALL AROUND CO L CO L #5 CLEVIS, TYP 4 5 ° R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 2 : 4 4 : 3 3 P M 1 1/2" = 1'-0" BT120 1 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGD111 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL SECTIONS AND DETAILS CANOPYLPDDJPAE LPD AJF AE 12/10/2024 385ISSUED FOR BID SCALE: 1 1/2" = 1'-0"BT120-SGE111 CANOPY BASE PLATE DETAIL 1 SCALE: 1 1/2" = 1'-0"BT120-SGE111 BOTTOM BEAM TO COLUMN CONNECTION DETAIL 2 SCALE: 1 1/2" = 1'-0"BT120-SGE111 BEAM TO EDGE CONNECTION AND SPLICE DETAIL 3 SCALE: 1 1/2" = 1'-0"BT120-SGE111 TOP BEAM TO COLUMN CONNECTION DETAIL 4 SCALE: 1 1/2" = 1'-0"BT120-SGE111 TOP OF COLUMN DETAIL 5 1 1 1 06/13/2025 ADDENDUM #1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 1 ' -8" - C OC LB"" 8 A L S - L 188 BS 8 CLAE"P B STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 WP 8" 1 1 / 2 " 3" 1 1 / 2 " 1 1/2" CL BM CL BM BM CL SYM, UNO BM L3X3X1/4 W/ (2) 5/8" DIA BOLTS 1/4 (3) SIDES 1/4" GAP SEE NOTE 1 NOTES: 1.FOR INTERIOR BEAM AT CANOPY END CONNECTION, SEE DETAIL 3/ THIS SHEET. 2.METAL DECK AND CHANNEL NOT SHOWN FOR CLARITY. SEE DETAIL 4/ THIS SHEET FOR METAL DECK AND CHANNEL AT BOTTOM INTERIOR BEAM. NOTES: REVERSE POSITION OF ANGLE AS SHOWN NOTES: 1.FOR INFORMATION NOT SHOWN, SEE DETAIL 1&4/ THIS SHEET. 1/4 (3) SIDES, TYP NOTES: DECK WP 3 1 / 2 " 1 1 / 2 " 3" 1 1 / 2 " 1 1/2" 1/4" GAP CL BM BM CL BM BM CL SYM, UNOL3X3X1/4 W/ (2) 5/8" DIA BOLTS 1/4(3) SIDES NOTES: 1. METAL DECK NOT SHOWN FOR CLARITY. NOTES: WP CL BM 7 3 / 4 " 1 1 / 2 " 3" 1 1 / 2 " 1 1/2" 1/4" GAP BM CL BM BM CL SYM, UNOL3X3X1/4 W/ (2) 5/8" DIA BOLTS 1/4(3) SIDES SEE NOTE 1 NOTES: 1.FOR EDGE BEAM AT CANOPY END CONNECTION, SEE DETAIL 3/ THIS SHEET. 2.METAL DECK NOT SHOWN FOR CLARITY. SEE DETAIL 4/ THIS SHEET FOR METAL DECK AT EDGE BEAM. 3.SUPPORT BEAM MATCHES SIZE OF FRAMING BEAM AT SIMILAR. NOTES: NOTES: 1.ANGLE SHALL START AND STOP A MAXIMUM OF 1-INCH FROM THE PERPENDICULAR FRAMING OR CONNECTION PLATES. NOTES: 1.ANGLE AND CHANNEL SHALL BEAR A MINIMUM OF 1 1/2-INCH AT ENDS OVER SUPPORTING ELEMENT. AT CONTRACTOR'S OPTION, PLATE AND CHANNEL TO BE CONTINUOUS OVER MORE THAN ONE SUPPORTING ELEMENT. WELD CHANNEL TO SUPPORTING ELEMENT WITH A FLARE BEVEL WELD AT EACH SIDE. C10 PER PLAN L3X2X3/16 LLH BENT PL3/16 X 2 X 3 LLV, SEE NOTE 1 METAL DECK AND CHANNEL AT INTERIOR BEAM METAL DECK AT EXTERIOR BEAM NOTES: NOTES: DECK HSS COL HSS BM 3/16 1" RETURN, SEE NOTE 1 3-12 3/16 3-12 HSS BM R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 8 : 2 4 A M 1 1/2" = 1'-0" BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGD112 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL SECTIONS AND DETAILS CANOPYLPDDJPAEISSUED FOR BID12/10/2024 SCALE: 1 1/2" = 1'-0"BT120-SGE111 BOTTOM INTERIOR BEAM CONNECTION DETAIL 1 SCALE: 1 1/2" = 1'-0" EDGE OR INTERIOR BEAM AT CANOPY END CONNECTION DETAIL 3 -SCALE: 1 1/2" = 1'-0"BT120-SGE111 TOP INTERIOR BEAM CONNECTION DETAIL 2 SCALE: 1 1/2" = 1'-0"BT120-SGE111 EDGE BEAM CONNECTION DETAIL A SCALE: 1 1/2" = 1'-0" METAL DECK CONNECTION DETAILS 4 BT120-SGD111 W P8"1 " / 2/83C 1 L 3 B " 3 8 W118CB81 /3 L M S C NN: 1N1OY, " W /2 "YW CU8 1 8 B 11W 15/Nov/2024 0386 RTA/CN 0205-24 CONC CURB PER CIVIL 2' - 0"1' - 0" 3" NOTES: 1.REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION ON THE TACTILE STRIP. NOTES: PAVEMENT PER CIVIL SOG TACTILE STRIP PER ARCH 2' - 0" 6'-0" 4" 1' - 0"1' - 0" 1" NOTES: 1.REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION ON THE TACTILE STRIP. NOTES: CONC CURB PER CIVIL PAVEMENT PER CIVIL SOG TACTILE STRIP PER ARCH ADA TACTILE STRIP PER ARCH HSS BM HSS3 1/2X1/4 HANGER 3' - 0 " M A X 2" M I N SLEEVE AND BM BY OTHERS BOLT BY OTHERS, SEE NOTE 1 3/16 NOTES: 1.CONTRACTOR TO COORDINATE HANGER'S BOLT HOLE LOCATION AND DIMENSIONS. 2.CONTRACTOR TO COORDINATE PLATE'S BOLT HOLE DIMENSIONS. NOTES: KCM RTIS 3/16 3/16 TYP 1/2" (2) PL1/4X2 @ 4" MAX 4" (3/16)NS,FS PL3/8X5x0'-9" W/ 2" DIA HOLE ON HANGER CTR HSS BM HSS2 1/2X1/4 HANGER 3' - 0 " M A X 3/16 SOUNDTRANSIT VMS 3/16 3/16 TYP 1/2" (2) PL1/4X2 @ 4" MAX 4" (3/16)NS,FS PL3/8X5x0'-9" W/ 2" DIA HOLE ON HANGER CTR 2 3/4" PL3/8X4X0'-7 1/2" W/ 1 3/4" DIA HOLE CTR ON HSS W/ (4) 5/16" DIA BOLTS @ 6 1/4" NOTE 2BM BY OTHERS NOTES: 1.SIGNAGE LOCATION PER ARCHITECT. CONTRACTOR TO COORDINATE. 2.PROVIDE INSULATION BETWEEN CARBON STEEL AND STAINLESS STEEL TO AVOID GALVANIC CORROSION. NOTES: HSS BM SIGNAGE 3/16T&B 3/16 3/16 PL1/4 CTR ON BENT PL 7" SIGNAGE SUPPORT NOTE 2BENT PL1/4X6" SECTION NOTES: 1.SIGNAGE LOCATION PER ARCHITECT. CONTRACTOR TO COORDINATE. 2.PROVIDE INSULATION BETWEEN CARBON STEEL AND STAINLESS STEEL TO AVOID GALVANIC CORROSION. NOTES: HSS GIRDER HSS6X2X3/16X0'-7", TYP SECTION NS & FS SIGNAGE SUPPORT NOTE 2 R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 8 : 2 5 A M BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGD113 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL SECTIONS AND DETAILS CANOPYLPDDJPAE ISSUED FOR BID12/10/2024 SCALE: NTS BT120-SFP212 SLAB ON GRADE AT TACTILE STRIP D SCALE: NTS BT120-SFP212 SLAB ON GRADE AT ADA TACTILE STRIP E SCALE: NTS BT120-SGE111 SCREEN MOUNT DETAIL A SCALE: NTS BT120-SGP312 SIGNAGE AT BEAM DETAIL B SCALE: NTS BT120-SGP312 SIGNAGE AT GIRDER DETAIL C C ON UR B PBNEIRR U V E L E N CUUNILNU BEV2R'I NN: 2N2O- 0 R C BP -C I"N U N L U UC 15/Nov/2024 0387 RTA/CN 0205-24 1/4 1/4 HSS MF COL ELEVATION WT8X50X0'-4 1/2" STL BM 2" 10" 5/16 5/16 CAP PL 5/8 PL 1/2 W/(2) 7/8" DIA BOLTSPL5/8 X 4 1/2 1 1 /2 "3 " 1 1 /2 " 1 " 1 " T Y P 1" WP WP PL 1/2 1/4 5/16 5/16 5/16 (3) SIDES (2) BOLT CONN PER TYP DTS 1/4 (3) SIDES 1. WHERE BEAM SLOPES, SLOPE TOP CONNECTION PLATE TO MATCH AND SUBSTITUTE WT WITH TWO PLATES THAT MATCH THICKNESS AND WIDTHS OF FLANGE AND WEB. WELD WEB PLATE TO FLANGE PLATE WITH A DOUBLE SIDED 5/16-INCH FILLET WELD. NOTES: ELEVATION STL BM MAY EXTEND BEYOND HSS COL PER PLAN PL 1/2 CAP PL 5/8 PL 3/8 W/(2) HOLES FOR 7/8" DIA BOLTS 5/16 5/16 1 " T Y P WP 1" 1/4 CONN PER TYP DTS HSS COL 1/4 NOTES: 1.PROVIDE AN ALL AROUND 1/4 INCH FILLET WELD FROM HSS TO BOTTOM FLANGE. NOTES: 1 1 /2 "4 " 1 1 /2 " 1 " ELEVATION STL BM TYP 1/4 1/4 PL 1/2 3" 1/4 1/4 WF TO PL 1/4 1/4 PL 1/4X7X7 1/2" 1 1/2" 1 1/2" HSS6X6X1/4 1 1 / 2 " 3" 3" 1 1 / 2 " ROOF DECK ROOF DECK 1/4T&B CAP PL 1/4 PL 1/4 X VARIES L3X3X31/4 3/16 2-8 PL TO WF FLG & L TO PL 3/16 2/8 1/2" TYP 1" SECTION HSS BM, NOTE 1 STL PL 1/4 1/4 1/4 3-12 1/4 4-12 1/4 4-12 4'-0" MAX PER ARCH 1' - 0" 1/4 3-12 STL PL TO HSS SLOPE PER ARCH NOTES: 1.HSS BEAM MAY BE AN HSS COLUMN, SEE PLAN. NOTES: 3/4" 1/4 (3) SIDES, TYP CAP PL HSS BM, TYP 1/ 2 " 1" PL3/8x2 1/2x0'-9" T&B PL3/8X4 1/2X0'-6" ES1/4 1/4TYP HSS BM 1/4 HSS COL PLS AT SIM, SEE NOTE 1 NOTES: 1.REFER TO "CORE FACILITY CANOPY SECTION" FOR INFORMATION NOT SHOWN. NOTES: HSS BM MITER CJP 1/4 (3) SIDES 1/4 (3) SIDES, TYP1" PL 5/16 X 2 X 0'-8" INCOMING BEAM AS OCCURS HSS BM 1/4 1/4 (3) SIDES, TYPSTIFF PL3/8 ES R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 8 : 2 7 A M BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGD121 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL SECTIONS AND DETAILS CORE FACILITYLPDDJPAEISSUED FOR BID12/10/2024 SCALE: 1 1/2" = 1'-0"BT120-SGE121 BRACE FRAME ABOVE BEAM 1 SCALE: 1" = 1'-0"BT120-SGE121 BRACE FRAME BELOW BEAM 2 SCALE: 1" = 1'-0"BT120-SGE122 FRAMING CONNECTION E SCALE: 1 1/2" = 1'-0"BT120-SGP321 CORE FACILITY CANOPY SECTION B SCALE: 1 1/2" = 1'-0"BT120-SGP321 HSS BEAM TO HSS BEAM A SCALE: 1 1/2" = 1'-0"BT120-SGP321 HSS BEAM TO HSS COLUMN C SCALE: 1 1/2" = 1'-0"BT120-SGP521 HSS CORNER DETAIL 3 SCALE: 1 1/2" = 1'-0"BT120-SGP521 CANTILEVER HSS DETAIL D 1 /4HS HM FM4CO S L C W H C 4 1SS4OW4S MCLT 8 O EEI:0E0LX 5 RPNTRE S A L OR I A E F R PN H 1 MF HX1 O04 S 4 W S S1 G F N GFR 15/Nov/2024 0388 RTA/CN 0205-24 HSS2X2X1/4 WP WP WP WP 1/4 1/4TYP 1/4 TYP 1/4NS&FS, TYP NS&FS, TYP HSS BM 1/4 1/4 TYP HSS HANGER, TYP GUSSET PL3/8, TYP TAPERED BM 1/4 PL1/2X5-3/4X0'-9" W/ (4) 1/2" DIA BOLTS @ BM GAGE 1" 3" 1/ 2 " 1"2"1" TYP 1" 1/4 1/4 CAP PL3/8, TYP STEM PL3/8, TYP (2) 1/2" DIA BOLTS, TYP 1/4 1/4 TYP 1/4 TYP GUSSET PL1/4 CJP (2) 1/2" DIA BOLTS KNIFE PL1/4 1/2" TYP TYP 1" 1" 1" HSS PRMT BM 1/2" 1" 1 1/2" 1" TYP 1/2" 1" 1 1/2" 1" 1/2" 6" 1/2" TYP TOS EL 36'-6" TOS EL 40'-2" WP WP WP WP 1/4NS&FS, TYP NS&FS, TYP HSS BM HSS HANGER, TYP TAPERED BM 1/4 PL1/2X5-3/4X0'-9" W/ (4) 1/2" DIA BOLTS @ BM GAGE 3" 1/ 2 " 1"2"1" 1/4 1/4 TYP 1/4 TYP GUSSET PL1/4 CJP (2) 1/2" DIA BOLTS KNIFE PL1/4 1/2" TYP 1" 1" HSS PRMT BM 6" TOS EL 36'-6" TOS EL 40'-2" R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 8 : 2 9 A M 3" = 1'-0" BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGD122 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL SECTIONS AND DETAILS CORE FACILITYLPDDJPAE ISSUED FOR BID12/10/2024 SCALE: 3" = 1'-0"BT120-SGE124 MEP CAGE SECTION AT BRACE A SCALE: 3" = 1'-0"BT120-SGE124 MEP CAGE SECTION B H S2X1/ X4 W42PT//1 Y P N X P 2 H112TN21 4PY&/F T , RPNTRE S A L OR I A E F R PN / X H 4 W X,H TB2 1 2 N 11H G F N GFR 15/Nov/2024 0389 RTA/CN 0205-24 HSS BEAM, TYP HSS POST 1/4 TYP WP HSS HANGER HSS BEAM WP 1/4NS & FS NS & FS HSS HANGER HSS BEAM, TYP NOTE 1 WP 1/4NS & FS, TYP NS & FS, TYP NOTES: 1.ONLY ONE BEAM FRAMING INTO HANGER AT SIMILAR. HSS HANGER WP STEM PL3/8 (2) 1/2" DIA BOLTS CAP PL3/8 1/4 1/4 1/4 GUSSET PL3/8 HSS BRACE HSS BM 1 " T Y P 1 "1 1 /2 " 1 " 1/4 1/4 1 /2 " 1 / 2 " T Y P NOTES: 1.REFER TO "MEP CAGE BOTTOM DETAIL B" FOR INFORMATION NOT SHOWN. NOTES: WP 1/4 1/4 TYP STEM PL3/8, TYP (2) 1/2" DIA BOLTS, TYP T Y P 1 " 1/ 2 " 1 "T Y P1 1 /2 "1 " 1 /2 " CAP PL3/8, TYP HSS BRACE, TYP 1/4 1/4 TYP 1/4 TYP TAPERED BM GUSSET PL3/8, TYP HSS HANGER 1 / 2 " T Y P NOTES: 1.REFER TO "MEP CAGE SECTION AT BRACE" FOR INFORMATION NOT SHOWN. NOTES: HSS BM HSS COL 1/4 (3) SIDES, TYP 1"2"1" (2) 1/2" DIA THRU BOLTS L3X3X5/16, TYP 1/4" TYP 1 1/2" HSS COL 1/4 NS,FS HSS BM, TYP HSS BM NOTE 1 HSS COL 1"2"1" (2) 1/2" DIA THRU BOLTS L3X3X5/16, TYP 1/4 (3) SIDES, TYP 1/2" NOTES: 1.COPE SIDE OF HSS BEAM TO ALLOW CONNECTION INTO HSS COLUMN. MAXIMUM COPE OF 3/4 INCHES. EXTEND STIFFENER PLATE 1-INCH BEFORE COPE. NOTES: 1/4" 3/16 TYP STIFF PL1/4 1' - 4" 1' - 4 " COL BASE PL 1 1/2 (t-1/8)PJP COL 1 1 / 2 " N O N - S H R I N K G R O U T ELEVATION PLAN 1 3/4"6 1/4"6 1/4" 1 3 / 4 " 6 1 / 4 " 6 1 / 4 " (8) 7/8" DIA AR W/ 12" EMBED 1 3/4" 1 3 / 4 " t MATCH WASHER SIZE, TYP R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 8 : 3 0 A M 1 1/2" = 1'-0" BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGD123 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL SECTIONS AND DETAILS CORE FACILITYLPDDJPAEISSUED FOR BID12/10/2024 SCALE: 1 1/2" = 1'-0"BT120-SGE124 MEP CAGE CORNER DETAIL 1 SCALE: 1 1/2" = 1'-0"BT120-SGE124 MEP CAGE BOTTOM DETAIL B 3 SCALE: 1 1/2" = 1'-0"BT120-SGE124 MEP CAGE BOTTOM DETAIL A 4 SCALE: 1 1/2" = 1'-0"BT120-SGE124 MEP CAGE BRACE BOTTOM DETAIL 5 SCALE: 1 1/2" = 1'-0"BT120-SGE124 MEP CAGE BRACE TOP DETAIL 6 SCALE: 1 1/2" = 1'-0"BT120-SGP321 SLOTTED WALL AT COLUMN DETAIL A SCALE: 1 1/2" = 1'-0"BT120-SGP321 SLOTTED WALL AT BEAM DETAIL B SCALE: 1 1/2" = 1'-0"BT120-SGE124 MEP CAGE COLUMN DETAIL 2 SCALE: 1 1/2" = 1'-0"BT120-SGE121 CORE FACILITY BASE PLATE DETAIL 7 H S BEABM ,M TYAA E P T O B T HEE YO E MTP1A/ Y 4 W NOTENS : L VAN I L S P N OT A B H M, B4H YN E O E EH R P T RPN 15/Nov/2024 0390 RTA/CN 0205-24 1' - 8" 1 1/2" 2 1/2" 2 1/2"2" 1/2" 2 1/4" 2 1/2" 2 1/4" DIAG BRACE CAP PL 5/8 STEM PL 1 1/4 W/ HOLES FOR (6) 7/8" DIA BOLTS GUSSET PL 1 WP 3/8 3/8 3/8 COL GUSSET PL AT SIM 3/8 3/8 BASE PL 1 1/2 1 1/2 NON-SHRINK GROUT 1 1/2" TY P ELEVATION 2"4"4"4"2" 1' - 4" 2" 4" 4" 4" 2" 1' - 4 " (12) 1 1/4" DIA CAST IN PLACE ANCHORS W/ 18" EMBED PLAN HSS TO BASE PL, FULL DEPTH PJP PILASTER, SEE ELEV (6 ) S T I R R U P S @ 3 " (12) #8 VERT PILE CAP REINF NOT SHOWN 3" 3" #5 STIRRUPS @ 6", UNO MATCH WASHER SIZE 3/16 TYP AT WASHER 1 1/2" 2" 2" 2"SYMCL1 1/2 " 2"1 1/2 " 9 1/2" 1/ 2" G AP 1/2 " T Y P 1/4 1/4 1/4 TYP 1/4 STEM PL TO CAP PL, TYP DIAG BRACE, TYP GUSSET PL 1/2 THRU 9/16" SLOTTED HOLES IN HSS AS SHOWN STEM PL 7/8, TYP (6) 5/8" DIA BOLTS, TYP CAP PL 3/8, TYP WP 1 1/2" 2"2"2" 1 1/2" 2" 1 1/2" 1/2" T Y P 1/2 " SYMLC 1/2" T Y P 1/4 1/4 1/4 1/4 1/4 DIAG BRACE CAP PL 3/8 STEM PL 7/8 GUSSET PL 1/2 (6) 5/8" DIA BOLTS COL 1/2" GUSSET PL AT SIM 5/16 WP DIAG BRACE GUSSET PL CHORD 4'-6" MAX 3'-6" MIN 1" 2" 4" 2" 1" 1"8"1" 10" 10 " (2) SPLICE PL 1/2 W/ (8) 5/8" DIA BOLTS DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 0 6 A M 1 1/2" = 1'-0" BT120 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGD131 12/10/2024R. PARGAS J. ALTCHECH OBSOLETE SECTIONS AND DETAILS CHARGING GANTRYLPDDJPAE LPD AJF AE 12/10/2024 391ISSUED FOR BID SCALE: 1 1/2" = 1'-0"BT120-SGE131 GANTRY FRAMING CONNECTION AT BASEPLATE DETAIL 4 SCALE: 1 1/2" = 1'-0"BT120-SGE131 GANTRY CROSS BRACE DETAIL 1 SCALE: 1 1/2" = 1'-0"BT120-SGE131 GANTRY LOWER TOWER K-BRACE DETAIL 2 SCALE: 1 1/2" = 1'-0"BT120-SGE131 GANTRY CHORD SPLICE DETAIL 3 DELETED 1 06/13/2025 ADDENDUM #1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 1 ' -8" - / 2/ 4D"" 8 I 4 A - 4 188 DA 8 /4 I G "B D STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 WP 1/4 TYP 1/4 1/4 TYP 1/4 1/4 COL 1/2" TYP STEM PL 'a' STEM PL 'a' STEM PL 'a' 1 1/2"2"2"2" 1 1 / 2 " 2" 1 1 / 2 " PL 7/8 W/ (6) 5/8" DIA BOLTS 1 1/2"2"2"2" 2 1 / 2 " 2" 2 1 / 2 " STEM PL 'b' PL 7/8 W/ (6) 5/8" DIA BOLTS STEM PL 'b' STEM PL 'c' STEM PL 'b' STEM PL 'c' PL 5/8 W/ (4) 5/8" DIA BOLTS 1 1/2"2"2" 1 1 / 2 " 2" 1 1 / 2 " GUSSET PL 1/2 X 9 X 2'-8" GUSSET PL 1/2 X 8 1/2 4 1 / 2 " CHORD, TYP 1/2" TYP DIAG BRACE, TYP WP 1/4 TYP 1/4 1/4 TYP 1/4 1/4 COL 1/2" TYP STEM PL 'a' STEM PL 'a' STEM PL 'a' GUSSET PL 1/2 X 9 X 2'-8" HORIZ 1/2" T Y P CAP PL 3/8, TYP CAP PL 3/8, TYP SIDE PL 1/2 X 4 X 1'-4" 1/4 SIDE PL @ FS STEM PL 'd' 1/ 2 " T Y P 1/ 2 " T Y P 1 1/2" 1/2" GAP 6 1/2" CAP PL 3/8 1/4 GUSSET PL 5/8 1/4 1/4 (1/2) COL STEM PL 'd' PL 5/8 W/ (4) 7/8" DIA BOLTS 1 1/2"2"2" 1 1 / 2 " 2" 1 1 / 2 " (2) STEM PL 'e' 1/ 2 " T Y P 1/ 2 " T Y P 1 1/2" 1/2" 6 1/2" CAP PL 3/8 1/4 GUSSET PL 5/8 1/4 1/4 (1/2) COL STEM PL 'e' PL 3/8 W/ (4) 7/8" DIA BOLTS 1 1/2"2"2" 1 1 / 2 " 2" 1 1 / 2 " SIDE PLWP COLSIDE PL CHORD, TYP DIAG BRACE, TYP GUSSET PL, TYP CAP PL, TYP STEM PL, TYP A A SECTION A BB SECTION B C C SECTION C D D SECTION D 5/16 AT HSS W/ WALL THK OF 5/16" TY P 1/2" 1/ 2 " STOP GUSSET AT SIM WHERE APPLICABLE 1 /2 " T Y P WP 1 1/2" 2 " 1 1/2" 1/2" SYMLC 1/2 " T Y P1/4 1/4 1/4 DIAG BRACE CAP PL 3/8 STEM PL 5/8 GUSSET PL 1/2 (4) 5/8" DIA BOLTS CHORD 1 / 2 " 1/2 " T Y P 1 1/2" 2" 2" WP 1 1/2" 2" 1 1/2" 1/2" SYMLC 1/2" TYP 1/4TYP 1/4 1/4TYP CAP PL 3/8 STEM PL 5/8 GUSSET PL 1/2 (4) 5/8" DIA BOLTS CHORD 1/2" TYP 1 1/2" 2"2"1/ 2 " 2" 2" 1 1 / 2 " STEM PL 5/8 W/ (2) 5/8" DIA BOLTS WP 1 1/2" 2" 1 1/2" 1/2" SYMLC 1/2" TYP 1/4TYP 1/4 1/4TYP, NOTE 1 CAP PL 3/8 STEM PL 5/8, EACH SIDE OF GUSSET GUSSET PL 1/2 (4) 5/8" DIA BOLTS CHORD 1/2" TYP 1 1/2" 2"2"1/ 2 " 2" 2" 1 1 / 2 " STEM PL 5/8 W/ (2) 5/8" DIA BOLTS NOTES: 1.OMIT ONE INTERNAL FILLET WELD WHERE THERE ARE (2) STEM PLATES. NOTES: DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 0 8 A M 1 1/2" = 1'-0" BT120 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGD132 12/10/2024R. PARGAS J. ALTCHECH OBSOLETE SECTIONS AND DETAILS CHARGING GANTRYLPD DJP AE LPD AJF AE 12/10/2024 392ISSUED FOR BID SCALE: 1 1/2" = 1'-0"BT120-SGE131 GANTRY UPPER TOWER K-BRACE DETAIL 1 SCALE: 1 1/2" = 1'-0"BT120-SGE131 GANTRY VERTICAL BRACING DETAIL 2 SCALE: 1 1/2" = 1'-0"BT120-SGP331 GANTRY HORIZONTAL BRACING DETAIL 3 SCALE: 1 1/2" = 1'-0"BT120-SGP331 GANTRY HORIZONTAL BRACING DETAIL 4 DELETED 1 06/13/2025 ADDENDUM #1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 W P1/4T/ Y CY1OLTT 4 2 O " / O 1 W441L"14 YO2 TS L STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 WP LC 1/4 1/4 1/4 CAP PL 3/8 GUSSET PL 1/2 X 8" X 8" CHORD 1/ 2 " 2" 2" 1 1 / 2 " STEM PL 5/8 W/ (2) 5/8" DIA BOLTS 1/2" TYP BRACE HSS BM 4" CHORD 3/16NS,FS 3/16 (4) FLAT SIDES HSS BM ELEVATION HSS POST 3/16 (3) SIDES, TYP PL1/4X3 ES HSS BM HSS POST SECTION 1/2" DIA THRU BOLT1 1 / 2 " 3" 2 1 / 2 " DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 1 1 : 2 8 : 0 9 A M 1 1/2" = 1'-0" BT120 S1-BT120-S-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 L. DOWELL R. MUNRO A. FORTNER A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGD133 12/10/2024R. PARGAS J. ALTCHECH OBSOLETE SECTIONS AND DETAILS CHARGING GANTRYLPDDJPAE LPD AJF AE 12/10/2024 393ISSUED FOR BID SCALE: 1 1/2" = 1'-0"BT120-SGP331 GANTRY HORIZONTAL SINGLE BRACE DETAIL 1 SCALE: 1 1/2" = 1'-0"BT120-SGE131 ACM SUPPORT BOTTOM CONNECTION DETAIL A SCALE: 1 1/2" = 1'-0"BT120-SGE131 ACM SUPPORT MID CONNECTION DETAIL 2 SCALE: 1 1/2" = 1'-0"BT120-SGE131 ACM SUPPORT POST CONNECTION DETAIL 3 DELETED 1 06/13/2025 ADDENDUM #1 1 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 W PLC1/ C4 A4L 3// 1 8 G C L W11L3GL1 4 8 U /S 3 STAT E O F WASHING T O N S T R U CTURAL E N GINEER P R O FESSIONAL E N G INEER ALEJAND R O E SPARZA G O N Z A LEZ 22016264 2/June/2025 A - NOTES: 1.REFER TO CIVIL DRAWINGS FOR LOCATION OF RETAINING WALL, DIMENSIONS NOT SHOWN IN THIS SET, AND WALL PROFILE. 2.RETAINING WALL SHALL BE PLACED ATOP COMPACTED STRUCTURAL FILL IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. BACKFILL OF RETAINING WALL SHALL ALSO BE PER THE GEOTECHNICAL REPORT. REFER TO GEOTECHNICAL REPORT FOR ADDITIONAL REQUIREMENTS. 3.COMPACTION WITHIN 3'-0" HORIZONTALLY TO THE RETAINING WALL SHALL BE PERFORMED WITH LIGHTWEIGHT, HAND-OPERATED EQUIPMENT. 4.ADEQUATE DRAINAGE BEHIND RETAINING WALL SHALL BE PROVIDED. REFER TO CIVIL DRAWINGS FOR MORE INFORMATION. 5.NOTIFY THE STRUCTURAL ENGINEER WHERE LIMITATIONS NOTED IN THE STRUCTURAL DRAWINGS CANNOT BE MET. RETAINING WALL NOTES: B - STEP LOCATIONS AND DIMENSIONS PER CIVIL ST BT BW 12" MAX 4" MIN 12" MAX 6" MIN TRANSIT CENTER FINISH GRADE EL PER CIVIL SLR #5@12" BLR#4@12" T&B #4@16" EMBED PL1/2 X12 W/ (4) 1/2" DIA STUDS @ 9", 6" MIN EMBED NOTE 3, 4 WH 4' -0" M A X ADDL (1) #4 CONT AT HOOK 4" (2) ADDL #5 CONT BARS AT STUD EDGES FENCE PER CIVIL SEE NOTE 4CONDUIT, 1 1/2" OD MAX 1 3/4" MAX HOLE TOF TOW CL WALL STRC ALIGNMENT RETAINING WALL SCHEDULE WH ST BT BW SLR BLR ≤2'-0"10"18"#5@12" ≤3'-0"10"18" ≤4'-0"10"18" 4'-8" 5'-2" 6'-0" #5@12" #6@12" #5@8" #5@8" #5@8" NOTES: 1.REFER TO "RETAINING WALL PLAN AND NOTES" FOR ADDITIONAL INFORMATION. 2.HOOK REINFORCING AT ENDS. PROVIDE A 2'-0" SPLICE WHERE REQUIRED. 3.EMBED PLATE IS PROVIDED TO CONNECT THE METAL FENCE TO THE RETAINING WALL. CONTRACTOR TO COORDINATE THE EXACT LOCATION OF PLATES WITH FENCE SYSTEM CHOSEN. CONTRACTOR TO COORDINATE RETAINING WALL REINFORCING WITH EMBED PLATES. THE CONNECTION HAS BEEN DESIGNED WITH THE ASSUMPTIONS: a. 6'-0" TALL FENCE b. 8'-0" MAXIMUM SPACING BETWEEN POSTS c. 50% POROSITY OF FENCE d. 8'-0" TALL POST WHERE CAMERA IS MOUNTED. 4.REFER TO ELECTRICAL DRAWINGS FOR CONDUIT SIZE AND LOCATION. CONDUIT SHALL NOT PENETRATE RETAINING WALL WITHIN 12" FROM TOP OF FOOTING. PLACE HOLE IN EMBED PLATE AT CENTER, ALIGNED WITH CENTER OF POST. NOTES: <=1'-0"10"18"#4@12"4'-3"#5@8" WALL STEM STEP LOCATION WALL FTG STEP LOCATION HOOK STEM HORIZ REINFORCE WHERE INTERRUPTED, TYP SPLICE STEM HORIZ REINF, NOTE 2 AT THICKENED FTG, EXTEND STEM VERT REINF TO BOT OF FTGHOOK FTG HORIZ REINF WHERE INTERRUPTED, TYP MATCH SIZE AND SPCG OF FTG HORIZ REINF, TYP NOTES: 1.STEP LOCATION PER CIVIL. FOOTING AND STEM STEPS MAY BE AT THE SAME LOCATION. 2.AT CONTRACTOR'S OPTION, STEM HORIZONTAL REINFORCING MAY BE CONTINUOUS THROUGH STEP. 3.ONLY REINFORCING AT WALL AND FOOTING STEP CONDITIONS SHOWN THIS DETAIL. 4.AT CONTRACTOR'S OPTION, SLOPE SUBGRADE AT 1:1 IN LIEU OF STEPPED BOTTOM OF FOUNDATION. NOTES: TYP 2' - 0" TYP 1' - 0" TYP 2' - 0" SEE NOTE 4 10" MAX 2' - 0" MAX 1' - 6" 2' - 0" DECORATIVE WALL (3)#4 #4@12" FINISH GRADE PER CIVIL MIN6" 1' - 0" 1 3" TYP 1 1" TYP #4@12" #4@12" 3/16 3/16NOTE 5 A242 EMBED PL1/2X12 @ 36" W/ (4) 1/2" DIA STUDS 6" MIN EMBED, NOTES 3 & 6 RETAINING WALL NOTE 2 A242 PL1/4 NOTE 1 NOTES: 1.REFER TO LANDSCAPING DRAWINGS FOR PLATE PROFILE, PANELING, AND POROSITY. ROUND TOP EDGE OF PLATE. 2.REFER TO LANDSCAPING DRAWINGS FOR RETAINING WALLS PROFILE AND LOCATION. RETAINING WALLS MAY SLOPE PER CIVIL DRAWINGS. BEND LONGITUDINAL REINFORCING TO MATCH SLOPE. 3.PLACE THE CENTER OF THE FIRST EMBED PLATE 18 INCHES FROM THE VERTICAL PLATE PANEL END, RETAINING WALL END, AND RETAINING WALL BEND. CONTRACTOR TO ENSURE THERE IS A 2-INCH CLEAR COVER BETWEEN ANY PORTION OF THE EMBEDDED PLATE ASSEMBLY AND WALL REINFORCING. 4.REFER TO "RETAINING WALL PLAN AND NOTES" FOR GEOTECHNICAL INFORMATION. 5. USE WEATHERING STEEL ELECTRODES. 6. PAINT FACES OF EMBEDDED PLATE THAT WILL BE EMBEDDED IN CONCRETE. NOTES: 2' - 6" SEAT WALL FINISH GRADE PER CIVIL MIN6" 2' - 0" 10" MAX 2' - 0" SITTING WALL NOTE 2 #4@12" EF #4@12" CHAMFER PER LANDSCAPING DRAWINGS (3)#4 #4@12" 6" 4" TYP (3) #4 POLYSTYRENE PER TYP DTS DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-S-v2020.rvt 1/23/2025 5:58:27 AM BT120 0 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGD161 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL SECTIONS AND DETAILS RETAINING WALLLPDDJPAEISSUED FOR BID12/10/2024 SCALE: 1/4" = 1'-0"BT120-SFP001 RETAINING WALL PLAN AND NOTES 1 SCALE: 3/4" = 1'-0" RETAINING WALL SECTION DETAIL A - SCALE: 3/4" = 1'-0" RETAINING WALL AT STEP DETAIL B -SCALE: 3/4" = 1'-0"BT120-SFP001 ARCHITECTURAL RETAINING WALLS C A N OTE ST: B:ORISS E G R T R O AEEOI OE :R G W SLI 22016264C H ALEJA N D O S PA G O N Z A L E S T A :B TCA I DO E O E EA R Z E RZA 17/Jan/2025 394 RTA/CN 0205-24 A - B - SIM 6' - 8" 2' - 6 " NOTES: 1.REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF WINDSCREENS. NOTES: HSS4X2X1/4 HS S 4 X 4 X 1 / 4 HS S 4 X 4 X 1 / 4 HSS4X2X1/4 HSS4X2X1/4 SOG PLATFORM PER CIVIL 2' - 4 " 4' - 0 " PE R A R C H 7' - 0 " MA X NS & FS, TYP 1/4TYP PL1/4 CAP, TACK WELD ALL AROUND, TYP C - HS S 4 X 2 X 1 / 4 3' - 10" 1/4 TYP NS & FS, TYP HSS4X2X1/4 HSS4X2X1/4 HSS4X2X1/4 C - NOTES: 1.REFER TO "WINDSCREEN MAIN ELEVATION" FOR MISSING INFORMATION. NOTES: A - 7' - 8" NOTES: 1.REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF WINDSCREENS. NOTES: 1/4 1"4" 3" EMBED PL1/2 W/ (2) 1/2" DIA STUDS, 4" MIN EMBED NOTES: 1.PROVIDE 1/2" DIA WEEP HOLE 1" ABOVE BASE PLATE, TYP AT POSTS NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 8 : 3 8 A M BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 L. DOWELL R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGD162 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL SECTIONS AND DETAILS WINDSCREENLPDDJPAEISSUED FOR BID12/10/2024 SCALE: 1" = 1'-0" WINDSCREEN PLAN - ANGLED 2 BT120-SFP213 SCALE: 1" = 1'-0" WINDSCREEN MAIN ELEVATION A -SCALE: 1" = 1'-0" WINDSCREEN ANGLED ELEVATION B - SCALE: 1" = 1'-0"BT120-SFP212 WINDSCREEN PLAN - STRAIGHT 1 SCALE: 1 1/2" = 1'-0" WINDSCREEN BASE PLATE C - TYP TYP A BNOTEOS :SNCREE T I C D OC N ATTNRDNT SCI EU R --'2C-CSP H RPNTRE S A L OR I A E F R PN E O A S: OPA R1N T N D T TA G F N GFR 15/Nov/2024 0395 RTA/CN 0205-24 PLATFORM OR CURB B - B - 8" SOG UNDER SHELTER W/ #6 @ 16" OC EWHSS4X4X1/4TYPTYP 1' - 0 " 3' - 0 " A - A - TYP 2 PLACES TYP 3 PLACES 1.LAP SHELTER FOUNDATION REINFORCING WITH PLATFORM REINFORCING WHERE OCCURS. 2.NOTED GRIDS APPLY TO KCM SHELTER ONLY. TY P 2' - 0 " REBAR NOTE 1 2 1 NOTES: GRID GRID GRID 16' - 8" TYP 1' - 0"8' - 4"8' - 4" B - B - A - A - 1' - 0 " 3' - 0 " 2' - 3 " 1' - 0"16' - 8"1' - 0" 8' - 4"8' - 4" NOTE: 1.ALL SEAMS ARE TO BE CONCEALED OR GROUND FLUSH AND SANDED SMOOTH. 2.ALL EXPOSED SURFACES ARE TO BE FINISHED SMOOTH. 3.ALL EXPOSED WELDS TO BE GROUND FLUSH AND SMOOTH. FINISH RADIUS TO MATCH STRUCTURAL TUBE. 4.NOTED GRIDS APPLY TO KCM SHELTER ONLY. HSS4X4X1/4 TYP NOTES: 2 BT120-SGD164 3 BT120-SGD164 TYP A BT120-SGD164 GRID GRID GRID 1. REFER TO CIVIL DRAWINGS FOR TOP OF CONCRETE ELEVATION. NOTES: GRID GRID TOS EL 37'-4" AT KCM SHELTER 34'-2" AT PARATRANSIT SHELTER TOS EL 37'-1" AT KCM SHELTER 33'-11" AT PARATRANSIT SHELTER 1 BT120-SGD164 TYP GRID R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 8 : 3 9 A M 1/2" = 1'-0" BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 M. BUNIYA R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGD163 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL PLANS AND ELEVATIONS PARATRANSIT SHELTER 1MKBDJPAE ISSUED FOR BID12/10/2024 SCALE: 1/2" = 1'-0"BT120-SFP001 FOUNDATION PLAN - PARATRANSIT AND KCM SHELTERS 1 BT120-SFP215 SCALE: 1/2" = 1'-0"BT120-SFP001 ROOF PLAN - PARATRANSIT AND KCM SHELTERS 2 BT120-SFP215 SCALE: 1/2" = 1'-0" SHELTER ELEVATION - FRONT A -SCALE: 1/2" = 1'-0" SHELTER ELEVATION - SIDE B - P LATFOTR MRA COO F U B T A PFFACBAF R U -O8 C BBE3-B-A" S T YP T T T Y P O T P RM T"P CGA F A B F FP P T 15/Nov/2024 0396 RTA/CN 0205-24 SECTION 1/4 (3) SIDES, TYP 5/8" DIA ANCHOR BOLT W/ 5" EMBEDMENT, NOTE 3 1/4" DIA WEEP HOLE PL1/2 REF MIN 1 1 / 2 " 1 1 / 2 " HOLE FOR THRU BOLT PL1/2 CL 3/4" DIA THRU BOLT NOTE 1 & 2HSS COL HSS3 1/2X3 1/2X3/16 SHOE HSS WALL CUTOUT NOTES: 1.DRILL HOLES PARALLEL TO FRAME WIDTH. 2.USE A STAINLESS STEEL HEXBOLT WITH WASHER AND SPANNER HEAD. PROVIDE INSULATION BETWEEN CARBON STEEL AND STAINLESS STEEL TO AVOID GALVANIC CORROSION. 3.BEARING SHOE SHALL BE ANCHORED TO CONCRETE THROUGH THE PLATE. 1' - 0 " 3" 2 3/4" NOTES: TOC NOTES: 1.PLACE A 1/4 INCH DIAMETER WEEP HOLE AT EITHER EDGE OF THE BOTTOM OF THE SLOPE OF THE ROOF BEAM. HSS BM TYP BUTT WELD ALL AROUND 1/8" ROOT GRIND FLUSH SAND SMOOTH NOTES: 1/4NS & FS NOTES: 1.PLACE A 1/4 INCH DIAMETER WEEP HOLE AT LOW SIDE OF TRANSVERSAL BEAMS. HSS BM TYP T & B NOTES: T&B ES 1/4NS & FS NOTES: 1.PLACE A 1/4 INCH DIAMETER WEEP HOLE AT LOW SIDE OF TRANSVERSAL BEAMS. HSS BM TYP HSS COL 1/4NS & FS NOTES: R PNTESTA LANOISS E F O G T O N REENIGNE AOFWSHI 22016264U C A LEJAN D O SPA G O N Z A L E S T R AL TUR I N E N G E ER R Z E RZA DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - S - v 2 0 2 0 . r v t 11 / 1 4 / 2 0 2 4 1 1 : 0 8 : 4 0 A M 1 1/2" = 1'-0" BT120 S1-BT120-S-v2020 12/10/2024 12/10/2024 M. BUNIYA R. MUNRO D. PRINDLE A. ESPARZA STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-SGD164 12/10/2024R. PARGAS J. ALTCHECH STRUCTURAL SECTIONS AND DETAILS PARATRANSIT SHELTER 2MKBDJPAE ISSUED FOR BID12/10/2024 SCALE: 1 1/2" = 1'-0"BT120-SGD163 BASE PLATE DETAIL 1 SCALE: 1 1/2" = 1'-0"BT120-SGD163 CORNER DETAIL 2 SCALE: 1 1/2" = 1'-0"BT120-SGD163 HSS BEAM TO HSS BEAM CONNECTION DETAIL 3 SCALE: 1 1/2" = 1'-0"BT120-SGD163 TOP OF BEAM DETAIL A S ECTIOTN :NCRDO O I R B T R C SIICDBCI NR U OA D 11)DC1C/P H RPNTRE S A L OR I A E F R PN O T S N: TPS D1C I C B IIS G F N GFR 15/Nov/2024 0397 RTA/CN 0205-24 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - A - v 2 0 2 0 . r v t 1/ 2 0 / 2 0 2 5 1 1 : 0 0 : 3 9 A M BT120 0 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AZN001 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE MATERIAL ABBREVIATIONS TRANSIT CENTER12/10/2024 J.C.D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID OVERLFOW NOZZLE PREFINISHED NOZZLE WITH INSECT SCREEN AT OVERFLOW DRAIN AT COLUMNS. METAL COLUMN COVER CONCEALED- FASTENER METAL COLUMN COVERS AT BUS PLATFORM CANOPY. 07 62 00 SHEET METAL FLASHING AND TRIM METAL COPING SYSTEM COPING SYSTEM AT LOWER ROOF OF CORE FACILITY SECURITY OFFICE & STORAGE. METAL SOFFIT PANELS METAL SOFFIT SYSTEM AT CANOPY, CORE FACILITY AND BEB EQUIPMENT YARD METAL ROOF METAL ROOF SYSTEM AT CANOPY, CORE FACILITY AND BEB EQUIPMENT YARD 07 41 13 METAL ROOF PANELS UNDERSLAB VAPOR RETARDER THROUGHOUT CONCRETE SLAB FOR CORE FACILITY 07 26 16 UNDERSLAB VAPOR RETARDER R## INSULATION INSUL-1: FILL VOID BETWEEN STRUCTURAL MEMBERS AT CONDITIONED SPACE. INSUL-3: AT CAVITY WALL OUTSIDE OF SHEATHING & ABOVE ROOF DECK. INSUL-4: AT CEILING AND WITHIN STUD WALLS. INSUL-7: UNDERSLAB AND PERIMETER OF FOUNDATION. INSUL-9: AT EXPOSED STRUCTURE CEILING. 07 21 00 THERMAL INSULATION FORMED METAL WALL PANELS FLUSH PROFILE, CONCEALED-FASTENER WALL PANEL AT THE CORE FACILITY BLDG 07 42 13.13 FORMED METAL WALL PANELS 07 THERMAL & MOISTURE PROTECTION SHEATHING 5/8" GYPSUM SHEATHING FOR CAVITY WALL ASSEMBLIES AT CMU 06 16 43 GYPSUM SHEATHING AIR BARRIER AIR BARRIER 06 10 53 MISCELLANEOUS ROUGH CARPENTRY 06 WOOD, PLASTICS AND COMPOSITES WMP-6 STEEL GRATING WMP-5 ALUMINUM PERFORATED PLATE WALL PANEL WMP-4 ALUMINUM PERFORATED PLATE WALL PANEL WITH CUSTOM GRAPHIC 05 75 00 DECORATIVE FORMED METAL GDR-9 STAINLESS STEEL RAILING 05 73 00 DECORATIVE METAL RAILINGS 05 METALS ACCENT CMU CMU 4: GROUND FACE FINISH, COLOR TO BE SELECTED FIELD CMU CMU 3: GROUND FACE FINISH, COLOR TO BE SELECTED 04 22 00 CONCRETE UNIT MASONRY 04 MASONRY WSDOT SPEC SECTION 5-05.2 OPT1.GR5 CIP-A PIGMENT COLOR FOR "BRICK RED" CEMENT CONCRETE, SAE AMS-STD-595 COLOR #32169 CIP-3 FORMED FINISH W/ FORMLINERS, ALSO REFERENCE WSDOT SPECIFICATION CIP-1 CAST-IN-PLACE CONRETE FINISH TYPE 1, TYPICAL PLATFORM FINISH 03 35 00 CONCRETE FINISHING 03 CONCRETE SPECIFICATION TITLE AND DIVISION NUMBER DRAWING / SPECIFICATION NOMENCLATURE DESCRIPTION MATERIAL ABBREVIATIONS ON DRAWINGS AND SPECIFICATIONS LR-1 LEAN RAIL BENCH-2 STAINLESS STEEL BENCH WITH BACK BENCH-1 STANLESS STEEL BENCH TRASH & RECYCLING RECEPTACLES 12 93 00 SITE FURNISHINGS SSCT COUNTERTOP ABOVE CASEWORK AT SECURITY OFFICE AND LACTATION ROOM 12 36 61 SOLID SURFACING COUNTERTOPS PLDC PLASTIC-LAMINATE DESKTOP COUNTER AT SECURITY OFFICE 12 32 16 MANUFACTURERED PLASTIC-LAMINATE-CLAD CASEWORK 12 FURNISHINGS C-5 HI-LITE YELLOW, CMYK 0/32/95/0 C-4 KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U C-3 WAVE TEAL, CMYK 92/23/22/32 C-2 LAND GRAY, CMYK 0/0/0/6 C-1 RAILWAY GRAY, CMYK 0/0/0/80 COLOR HPC-3 FOR EXPOSED GALV STRUCT STEEL HPC-2 HIGH-PERFORMANCE COATING FOR EXPOSED PRIMED STEEL HPC-1 ON CONCRETE AND CMU 09 96 00 HIGH-PERFORMANCE COATINGS PC-2 PRECAST CONCRETE PAVERS 09 32 19 MORTAR BED PAVER TILING PT-3 PORCELAIN TILES (O-T-1D) PT-2 TRUNCATED DOME WARNING TILES CT CERAMIC TILES 09 30 00 TILING 09 FINISHES GL-5 SECURITY GLAZING AT THE SECURITY OFFICE AND DOOR VISION GLAZING 08 88 53 SECURITY GLAZING PP-2 HORIZONTAL TRANSLUCENT OVERHEAD PANELS PP-1 CLEAR ACRYLIC VERTICAL PANELS 08 84 00 PLASTIC GLAZING APA-1 ART PANEL ASSEMBLY TYPE 1 GL-4 LAMINATED TEMPERED GLASS GL-2 GL-1 W/ GRAFFITI-RESISTANT FILM GL-1 TEMPERED SAFETY GLASS 08 80 00 GLAZING TRANSLUCENT PANEL TYPE I TRANSLUCENT PANELS W/ PREFINISHED ALUMINUM FRAME TRANSLUCENT PANEL SYSTEM INSULATED TRANSLUCENT PANELS W/ PREFINISHED THERMALLY BROKEN ALUMINUM FRAME 08 45 00 TRANSLUCENT PANELS SYSTEMS ALUMINUM STOREFRONT FRAME, SF-2 (SF-2) SECURITY OFFICE WINDOWS ALUMINUM STOREFRONT FRAME, SF-1 (SF-1) ART INSTALLATION AT WINDSCREENS AND CLERESTORIES AT CANOPY 08 44 10 GLAZED ALUMINUM FRAMED STOREFRONT AND CURTAIN WALLS METAL OVERHEAD DOOR ELECTRICALLY OPERATED SECTIONAL DOOR AT CORE FACILITY STORAGE 08 36 13 SECTIONAL DOORS 08 OPENINGS SPECIFICATION TITLE AND DIVISION NUMBER DRAWING / SPECIFICATION NOMENCLATURE DESCRIPTION MATERIAL ABBREVIATIONS ON DRAWINGS AND SPECIFICATIONS 98 RTA/CN 0205-24 5.0' edge to edge R879.8024 R890.8024 CV DETV DETV DETV DETV PTZ DETV PTZ ND ND ND ND ND ND ND ND ND NDND ND ND RGRGRGRG RG RG RG RG RGRG CGCG RG CG CSCS CS VDVDVDVDVDVD CS SFSF SFSF SFSFSF SF VD VDVD VDVD CG CG CG CGCG CG CG SF SF SF CG CG CG SF SFSF SF CGCG CG CG CG CGCG VD VD VD SFSFSFSF SFSF VD VD VD VD VD VD VD VD VD VDVD VD VDVD VD VD VD VD VD MR MRMR MRMRMRMR MR VM CS CS CS SFSFMRMR SF MR SF SF SF SFSF SFSF SF CG MR MR VM VM VM VM VM VM VM VMVM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VMVM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM VM SFSFSF SF SFSFSF SF RG RG RG RG RG RG RGRG RGRGRGRGRGRGRGRGRGRGRGRGRGRG RGRGRGRGRGRGRGRGRGRG RG RG RGRGRGRGRGRG RG RG RG RG RG RGRG RG RGRGRGRGRGRGRGRG RGRGRGRGRG RG RG RGRGRGRGRGRG RG CS CS CS CS CS CS CS CS CS CS CSCSCSCSCSCSCSCSCSCS CSCSCSCSCSCSCSCSCSCSCSCS CS CS CS CSCSCSCSCSCS CSCS CS CS CS CS CS CS CSCS CS CS CS CGCGCGCG CG CGCG CGCG CG CG CG CGCG CGCGCG CGCGCGCGCGCGCGCGCG CGCGCG CG CG CG CGCGCG CS CS CS CS CS CSCS CS CS CSCSCS CSCSCSCS CSCSCS CS CSCSCSRG RG PAPAPAPAPAPAPAPAPAPAPAPAPAPA PAPAPAPAPAPAPAPAPAPAPAPAPAPAPAPA PA PAPAPA PAPAPAPA PAPAPAPARG PAPAPAPAPAPAPAPAPAPAPA CS CS CSCS CGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCG CG CG CG CGCG CG CG CGCG CGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCG CGCGCGCGCGCGCGCGCGCGCGCGCGCGCG CG CGCGCGCGCGCGCGCGCGCGCGCGCGCGCG CGCGCGCG CG CG CG CGCG CG CG CGCGCGCGCG CGCG CG CG CGCGCGCGCG CGCGCGCGCG CGCG CGCG CGCG CGCG CG KG KG KG KG KG KG KG KGKG SF SF SFSF SF SF SF SFSF SF SF SFSFSFSFSFSF SF VDVDVDVDVDVDVDVDVDVDVD VD VD VD VD VD VD VDVDVD VD VD VD VD VDVD VD VD SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSF SF SF SFSFSFSF SF SFSFSFSF SFSFSFSF KG KG KG KG KG KG KG KG KGKGKGKGKGKGKG KGKG KG KG KG KG KG KG KG KG KG KG KG KG KGKGKGKGKG KG KG KG CSCSCS CS CS CS CS CS CS CS CS CS CS CSCSCS CS CS CS CS CS CS CS CS CS CS CS CSCSCS CS CS CS CSCS CS CSCS CS CS CS CS CS CS CS CS CS CS CS CS CS CSCS CS CSCS CS CS CS CSCSCSCS CS CS CS CSCSCS CS CS CS CS CS RG RG RG RG RG RG MR MR MR MR MRMRMRMRMRMR MR MR MRMRMRMR MRMRMRMRMRMRMR ND ND ND ND ND ND ND NDND NDNDNDNDNDNDNDNDNDNDND NDND ND ND ND ND NDNDNDND ND ND NDND NDNDND NDNDNDNDND NDND ND NDNDND NDNDNDND ND ND ND NDND ND ND ND ND NDNDNDND VD VD VD VD VD VD VDVDVD VD VDVD VD VD RGRGRG RG RG RG RGRG RGRG RGRGRGRGRG RG RGRG RGRG RGRG RGRG RG CS CS CS CS CSCSCS CSCSCS CS CS CSCSCSCS CS CS CS CS CS CS CSCSCSCS CSCSCS CS CS CSCS CS CS CSCSCSCS CSCS CS CSCSCSCSCSCSCSCSCSCSCS CSCS CSCS CS CS CS CS CSCS CS CS CS CS CS CS CS CGCGCGCGCG CG CG CGCGCGCGCG CG CG CS CS VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VDVD VDVDVD VDVDVD VDVDVDVDVD KGKGKGKG KGKGKGKGKGKG KGKGKGKGKGKGKGKGKGKGKGKGKGKGKG SF SF SF SF SFSFSFSFSFSFSF SF SFSFSFSFSF SFSFSF SFSFSFSFSF SFSFSF SF SFSF SFSFSFSF VM VM VM VM VM VM VD VD VDCG VDVDVDVDVD VD VD VDVD VD CGCGCGCGCGCG CG CG CGCGCS CS MP MP MP MP MP MP MP MP MPMP MP MP MP MP MP MP MP MP MPMP MP MP MP MP MP MP MP SF SF SF SFSFSF SF MR MR MR MR MRMRMRMRMRMRMRMRMRMRMRMRMR MR MR MRMR MR MR MR MR MRMR MR MR MR MR MR MR MR MR MR MR MR MR MRMRMRMRMRMRMR MR MRMRMR MRMRMRMRMRMR MR MR MR MR MR MR MRMR MR MR CS CS CS CS CS CS CS CS CSCSCS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS WR WR WR WR WR WR WR WR WR WR WR WR WR WR WR WRWR WR WRWRWRWR WRWR WR WR WR WRWRWR WRWRWR WR WR WR WR WRWR WR WR WR WR WR WRWR WR WR WR WR WR CS CS CS CS CS CS CS CSCSCSCS CS CS CS CS CS CS CSCSCSCS CS CS CS CS CS CS CS CS CS CS CS CSCS CS WR WR WR WR WR WR WR WR WR WR WRWRWRWRWRWRWR WR WR WR WR WR WR WR WR WR WRWRWR WR WR WR WR WR WR WR WRWR WR WRWR WR WR WR WR WR WR WR WR WR WR WR CGCGCG CG CG CG CG CG CG CG CG CG CG CG CGCG CG CG CG CG CG CG CG CG CG CG CG CGCG CG CG CG CG CG CG CG RG RGRG RG RG RG RG RG RG RG RG RGRG RGRGRGRGRGRG RGRG RG RGRG RG RG RGRG RG RG RG RG RG RG RG RG RGRG RG RG RG RG RGRG RG RG KGKGKG KGCSCSCSCS CS CSCSCSCS CS CS CSCSCS CG CGCGCGCGCG PAPAPAPA PA PAPAPA PA PA PA PA PA PA PAPAPA PA PA PA PA PAPAPA PA PAPAPA PA PA PA CS CS CS CS CSCS CS CSCS CS CS CSCSCS CS CS CS CS CSCS CS CSCSCS CSCSCS CS CS CS CS CGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCG CG CGCGCGCGCGCGCGCGCGCGCGCGCGCG CG CGCG CGCGCGCG CGCGCGCGCGCGCGCGCGCG CG CGCGCGCGCGCGCGCGCGCGCGCGCGCG CG CG CGCGCGCGCGCGCGCG CGCGCGCG CGCGCGCGCGCGCGCGCGCGCGCG KG KG KG KG KG KG KG KGKG KG KG KG KGKGKG KG KG KG KG KG KG KG KG KG KG KG KG KG KG KG KG KGKGKGKGKG KG KGKG KG KG KG KG KG KGKG KGKG KGKG KGKG KGKGKGKG KGKG KGKG KGKG KG KG KGKG RGRGRGRGRG RGRG RGRG RGRGRGRGRGRGRGRGRG RGRG RGRG RG RGRGRG RG RGRG RG RGRGRGRGRGRGRGRGRGRG RG RG RG RG RG RG RGRG RGRG RG RG SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SFSFSFSF SF SFSFSFSFSF SFSFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SF SF KG SF SF SF SF SF SFSFSFSF SF SF SF SFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SFSF SF SFSF SF SF SF SF WR WR WR WR WR WR WR WR WR WR WR WR WRWR WR WR WR WR WR WR WR WR WRWRWRWRWRWR WRWR WRWR WR WR WR WR WR WR WR WR CS CS CS CSCS CSCSCS CS CSCS CS CS CS CS CS CS CSCS CS CSCS CSCS CS CS CS CS CS CS CSCSCS CS CS CSCS CS CSCS CSCS CS CS CS CS CS CSCS CS CS CSCSCSCSCS CSCSCSCSCS CS CSCSCSCSCS CS CSCSCSCSCSCSCSCSCS CSCS CSCSCSCSCSCSCS CS CS CS CSCS CS CS CS CS CS VM RGRGRGRG RGRG RGRGRGRGRG RGRGRGRGRGRGRGRG RGRGRGRGRGRGRGRG RGRGRGRG RG RGRG RGRG RGRG RGRGRGRGRG RGRG RG CGCGCGWRWRWR WR WRWR WRWRWRWR WR WR WR WRWR MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP VMVM RG RG RG RG RGRGRGRGRGRGRGRGRGRGRG RGRG RGRGRGRGRGRGRGRGRGRGRGRGRG RG RGRGRG RGRGRGRGRGRGRG RGRGRGRGRG RG RGRGRGRG RG RG RG RG RG RG RG RG RGRGRG RGRGRGRGRG RG RG RG RG RG RG RG RG RGRG RG RG RG RG RG RG RG RG RGRG RG RG RG RG RG RGRG RGRG VDVDVD VD VD VD VD VD VD VD VD VD VD VD VM VM VD VD VD VD VD VD VDVDVD VD VD VD VD VD VM VM VM VM CS CS CSCS CS CS CS CS CS CSCS CSCSCSCSCS CS CS CS CS CS CSCSCS CS CS VM VM VM VM ND ND ND ND ND ND ND ND ND ND ND NDND NDNDNDND ND ND ND ND ND ND ND ND ND ND ND NDND ND NDND WR WR WR WR WR WR WR WR WR WR WRWR CGCG CG CG CG CG CG CG CG CG CG CG CG CG VDVDVD VD VD VD VDVD VD VDVDVDVDVDVDVD VDVDVD MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MP MPMP MP KG KG KG KGKGKG KG KG KG KGKGKGKGKGKG KG KGKG KGKGKGKGKGKGKG MRMRMRMRMRMRMRMRMRMRMRMRMRMRMRMR MR MR MRMRMR MRMRMRMRMRMRMRMR MRMRMRMRMRMRMRMRMRMRMRMR MRMR MR MRMR NDNDNDND ND ND ND NDNDND NDNDNDND NDND ND ND NDNDNDNDNDND NDNDNDNDNDND NDND NDNDNDND ND ND CSCSCSCSCS CS CS CS CSCSCS CGCGCGCGCG RG VD VDVD VD VD VD VD VD VD VDVDVD VD VDVDVDVDVDVDVD RG RG RG RGRG RG RGRG VDVDVDVD VDVDVDVDVD VDVD VD VD PAPAPAPAPAPAPAPAPAPA PA PA PAPAPAPAPAPA PA PAPAPA CS CS CS CS CS CS CSCSCSCS CS CS CS CS CS CS CSCSCS CS CS CS CS CS CS CS CSCSCS RG RG RGRGRG RG RG RG RG RG RG RG RG RG RG RG RG RG RG RG RG RG RG RGRG WRWRWRWRWRWRWRWR WRWRWRWR WR WRWR WR WR WRWRWR WR WR WR WRWRWR WR WRWRWRWRWRWRWR WRWRWRWRWRWR WR WRWR WRWRWRWRWRWRWRWRWR WRWR KG KG KGKGKGKGKG KGKGKG KG KG KG KG KG KGKGKGKGKG KGKGKGKGKGKG KG KG KG KG KGKG KG KG KG WR WR WR WR WR WR WR WR WR WR ND ND ND ND ND ND ND ND NDNDNDND ND NDNDNDNDND NDNDNDNDND ND ND ND ND NDNDND NDND ND NDNDNDNDNDNDNDNDNDNDND ND ND ND ND ND ND NDNDND ND NDNDND ND NDND CG CG CGCGCGCGCGCGCGCG CG CG CGCGCGCGCG CGCGCGCGCGCGCGCG CGCGCGCGCG CGCGCGCGCGCGCGCGCGCG CGCG CGCG CGCG CG CG CGCGCGCGCGCG CGCGCGCGCGCG CGCG CG CGCGCG CG SFSF SFSFSFSFSF SF SF SFSF SFSFSFSFSF SF SFSFSFSF SF SF SF SF SFSF SF SF MR MR MR MR MR MR MR MR MRMRMRMRMRMR MR MR MRMR MR MR MR MR MR MRMR MR MR SFSFSFSF SFSF SFSFSF SF WR WR SF VD MRMR MRMR MR MR ND ND NDND ND ND ND ND ND ND ND ND ND RG RGRG RG RG RG RG RG CS CS CS CS CGCGCG CGCGCGCGCGCGCGCGCG CGCGCG CS RG CS CS CS CS CGCGCG CGCGCG CGCG CG RG RG RG RGRG RGRG RGRG CS CS CS CSCS CS CS CS CS MP MPMP MP MP MP MPMPMP MPMP MP MP MP ND ND NDVD VD VD NDND ND MRMR MR MR MR MR VD VD CGCG CGCG CGCG CGCG CGCGCGCG SF SFSF SFSFSF VDVD VDND VD VD MR MRMR MRMR MR NDND NDVD VD CGCGCG CGCGCG SFSFSF SFSFSFVD VDNDND NDVDVD VDMR MRMR MRMR MR CGCGCG CGCGCG NDND NDVD VD VD ND ND CGCGCG CGCGCG SFSFSF SFSFSF VD VDVD VDNDMR MRMR MRMR MR NDND NDVDVD VD VD VD VDND ND CGCGCG CGCG CGCGCG CGCGCGNDND ND VDCGCGCG CGCGCG VD VDND ND VDSFSFSF SFSFSF NDND ND VD VDVDNDND NDVDVD VDNDND ND CS WRWRWRWRWRWRWR ND ND NDND ND ND NDND ND ND CG CGCG CGCG CG CG CG CG CGCGCGCGCGCG CGCG CG RG RG RG RG RG RGRG RGRG RG CS CS CSCSCSCS CS CSCS CS CS CS RGRG RGRG RGCGCG CG CGCG CGCG CS CS CS CS CS CS CGCG CGCG CG CGND NDNDND ND ND CG CG CG CGCG CG CGCGCGCG RG CS RG RGRG RG CS CSCS ND CGCG CG CG NDND CG CGCGCG CS CS RGRG RG CGCG CG CG CG CG CGCGCG CG CGNDND ND ND ND ND ND ND ND ND ND ND ND NDND ND ND ND SF SF SFSFSF SF SFSFSF SFSF SFSF SFSF SFSF CS CS CS CS CS CS CSCSCS CSCS CS CS ND PA MR MR MRMR MR MRMRMR MRMRMRMR MRMRMRMRMR MRMR MR MRMR MR MR RGRGRG RG RG RG RG RGRG RG RG RGRG RGRGRG NDND ND ND ND ND NDND ND ND SF SFSFSFSF SFSF SF SF SFSF SF SF SF SF SF SFSF SF SF SFSF SFSFSF SF SFSFCSCSCS CSCSCS CS CSCSCS CSCS CS CSCS MR RGRG RG RGRGRG RG RG RG RG RG MRMRMR MR MR MR MRMR MR MR CGCG CGCGCG CG CG CGND ND ND NDND ND CG CGCG CGCG CGCG CS CSCS RG RGRG CG CG CGCGCG CGCG ND ND NDNDND CGCGCG CGCGCG CG CSCS CSCS CSCS RG RGRG RGCGCGCG CGCGCG CGCGCG CG CSCS CS CS CS CSCS RG RG RG RG CGCG CGCG CG CG NDND ND ND CG CGCG CG RG RG RG CS CS CS CG CG CG CG CG CG CGCG CGCG CG ND ND ND ND ND ND CG CG CG CGCG CG CSCS CSCS RG RG RG CG CGCG ND NDCGCGCGCG CS CS RG RG CG CGCGCG CGCG CSCS CS NDND NDND ND CG CGCG CG CGCGCGCGCGCG CG CG CGCGCGCGCG CGCGCGCGCGCGCGCGCG CGCG CG CGCG CGCGCGCGCGCGCG CGCGCG CGCGCS CS CS CS CS CSCS CSCS RGRG RGRG RG RGRG CGCGCGCGCGCGCGCG CG CGCG NDND ND ND NDNDND ND ND CG CGCG CGCGCG ND WR ND NDND ND WR WR WR WR CS CS CS CS CS CGCGCGCGCGCGCGCGCGCG ND ND ND ND ND ND WR WR WR WR WR CS CS CS CS CS CG CG CG ND ND WR CS CS CS CS CSCS CSCS CS CSCS WR WRWR WR WR NDND NDNDNDNDND NDNDNDNDNDND CGCGCG CGCGCGCGCGCGCGCGCGCGCGCG CSCS CSCSCS CSCS CG CG CG WRWRWRWR WRWRWR CS CS CS CS CG CGCGCGCGCGCGCGCGCGCGCGCG CGCGCG ND ND ND ND ND WR WR WR WR CS CS CS CSCSCSCS CGCGCG CGCG CGCGCG CG CGCGCGCGCGCG ND ND NDNDNDNDNDNDND WR WR WR WR WR WR WR CS CSCSCS CS CS CSCSCSCS CS CS CS CS CSCSCSCSCS CGCGCGCGCGCGCG CGCGCG CGCG CGCGCGCGCGCG CGCGCGCGCGCGCG CGCGCGCG CG CGCGCGCGCG CGCGCGCGCGCGCG CGCGCGCG CGCGCGCGCG CG CGCGCGCG CG CGCG CGCGCGCG WR WR WR WRWR WR WR WR WRWR WR WRWR WR WR WR WRWR WR WR WR WR WR WR NDND NDNDNDND CS CS CS CS CS CS CS CS CS CS CS CG CG CG CG CG CG CG CG CG CG CGCG ND ND ND ND ND ND ND ND NDND WR WR WR WR WR WR WR WR WR WR WR WR CSCS CSCS CSCS CS CS CS RG CGCGCG CGCGCG RG MRMRMRMR MRMRMR MRMRMR CSCSCSCS CS CSCSCS CS CSCSCGCGCGCGCGCG CGCGCGCGCGCGCGCG SFSFSF SFSFSFSFSFSFSF RG RG RGRG RG RGRGRG MRMRMRMRMRMRMRMRMR CS CS CS CS CS CSCS CS CGCGCGCG CGCGCGCGCGCGCG CG MR MRMR WR WR WR WR CG ND ND ND CS CS CS CS CS CS ND ND ND WR WR WR WR CS CS CS SFSF SFSFSFSFSF SF RG RG RGRG RGRG RG MRMR MRMRMRMRMR CS CSCS CS CSCS CS CGCGCGCG CG CG CGCG CGCGCG SFSFSFSFSFSFSFSFSFSFSFSF RG RGRGRG RGRGRGRG MRMRMR MRMRMR MRMRMRMR CSCS CS CSCSCS CGCG CG CGCG CGCG CGCG CG CG CG CG CG SFSFSFSF SFSFSF SFSF RG RGRGRG RG RGRG MRMR MRMRMR CSMRMR MRMR CS CSCS CSCS CGCGCGCGCG CG CG SFSFSF SFSFSF RG RG RGRGRGRGSF MRMRMR MRMRMR CS CS CS CS CS CS CS CGCGCG SFSFSFSFSFSFSF SF SF SFSF SF SFSF RG RG RGRGRG MP MP VD VDVD MP VD VDVD MP VD VDVD MP VDVD VD VD MRMRMRMR MRMR SFSF SF SFSFSFCSCSCSCSCSCSMRCGCGCGCGCGCGCGCGCG SF SF RG RGRGRGRGRGRGMRMRMRMR MRMRMRMRCS CS CS CSCSCS CGCGCGCGCGCGCGCGCGSFSF SF SFSFSF SF SF SF SF RGRG RGRGRGRG RGMRMRMR MRMRMRMR CS CS CSCS CSCS CGCGCGCGCGCGCG SFSFSFSFSFSFSF SF SFSFRG RG RGRGRGRGRGMRMR MRMRCSCSCSCSCS MP CGCGCG CG CS CS CS CSCSCSCS CS CS CS VD VD SFSFSFSFSF CG CGCG CG SF SF SF CG CG SF SF SF SF SFSF RG RG RG RG KG CG SF SFSF CG CGCG ND WR WR CG CG CG ND NDND WRWR WRWR CS CS CSCSCSCS ND NDNDNDNDND ND WR CS CS CS CS CGCGCGCGCGCG CGCGCG CG CGCGCGCGCGCGCG CG ND NDNDNDND ND ND ND WR WR WR WRWR WR WR WR CS CS CS CS CSCSCS CS CSCGCGCGCG CGCG CGCGCGCGCG NDNDND ND ND ND ND ND WR WRWRWR WR WR WR CG CGCG NDNDND ND CS CSCSCSCSCSCSCSCS ND NDNDND NDNDNDNDND WR WR WR WR WR WR WR WR WR WRCSCSCSCSCSCSCSCSCSCS WR WR WR WR CGCG CGCG ND ND ND ND NDNDNDND CG CGCG WR CS CS CS CSCSCSCSCSCS CGCGCGCGCGCGCGCG CGCGCGCGCGCGCGCGCG CGND NDND CG CGCG CS CS CS CS CS SF CG CG CG ND ND ND ND WRWR WRWR WRCS CSCS CS CS CSCG CG CG CGCG CG CSCS CS CS HS HSHS HS HSHS HS HS HS HSHS HS HS HS HSHS HS HS HSHSHSHSHS HS HSHSHSHS HSHS HSHS HSHS HSHSHS HS HS HSHSHSHSHSHSHS HSHS HSHSHSHS HSHS HSHSHSHSHSHS HSHSHSHSHS HSHSHSHSHSHSHS HS HSHSHSHSHSHSHSHSHSHSHSHSHSHSHSHSHS HSHSHSHSHSHSHSHSHSHS HSHSHSHSHSHSHSHSHSHSHS HSHS HSHS HSHSHSHSHS MP MP MP MP MP MP MP MPCSCSCS CS CS CSCSCS CG CG CG CGCGCGSFSFSF SFSFSF SFSFSF CG CGCG CGCG CGCG CG CG CG CG CG CG CG CG VD VD VD CS CSCS SF SF SFSFSF SFSFSFSF SFSF SFSFSF SFSF SF CS SF VM CS CS CSCSCS CS VDVDVD VD VDVDVDVD VDSFSFSF VD VD VDVD VDKG KGKGKG KG KG KG KG KG KG KG MR MR MR MRMR MRMR MR MR MR MR MRMR MRMRMR MR MR MR CS CS CSCS CS CS CS CS CSPA PAPA PA PAPA PAPA CS VM CSCS CS CS CGCGCGCGCGRGRGRGRG RGRGRG VD VD VD VD VD VDVDVDVD VD VDVD KG VM KGKGKG KG KG KG KGKG KG CSCS CSCS CSWR WRWRWR WR WR WR WR WR WR WRWRWRWRWRCGCGCGCGCGCGCGCGCGCGCGCGCG CGCGCGCGCG VDVD VDVD VDSF SF SFSFSFSFSFSFSF SFSF SFSF SFSF SF SF SF SF CS CS CSCS CS CS CS CS CS CSCS CS RGRG RGRG RGRG RG RG RGRG RGRG RGRG RG RG RGRG RGRG RGRGRG RGRG RG WR WR WRWRWR WRWR WRWRWR WR WR WRWR WR WR WR WR WR WR WR WR WR WR WR WR WRWR WR WR WR WR WRWR WR WR WR WR WR WRWR WR CG CGCG CGCG CG CG CG CGCG CG CGCG CG CGCG CS SF HS HS SF SFHS HS CB CB CBCB CB CB CBCS CSCB CB CB CBCB CBCB CBCBCB CB CBCB CB CB CB CB CBCB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CBCB CB SF CB CBCB CB CBCB CB CB CB CBCB CBCB CB CB CB CB CB CB CB CBCS KG CB CB CB CB CB CB CB CB CB CB CBCB CB CB CB CB CB CB CBSF CBCBCBCB CB CB CB CB CB CBCB CB CB CB CB CB CB CB CB CB FGFGFGFGFGFG FG FG FGFGFGFGFGFG FG FGFG FGFGFGFGFGFGFG FGFGFGFG FG SFSFSF SF VDVD VDVD VD CGCG CGCG CGND NDND NDND SFSFSF SFSF VD VDVD VDVD CGCG NDND ND CGCGCG PAPA ND PH PH PH PH MR MR MRMR MRMR MR MRMRMR MRMR MR MRMR MR MR MRMR MR MR MR MR MR MR MR MR MR MR MR MRMR MR MR MR MR MR MR MR MR MRMR MR MRMR MRMRMR MR MRMRMRMRMR MR MR MRMR MR MR MR MR MRMR MR MR MR MRMRMRMR MRMRMR MR MRMRMRMRMRMR MRMR MRMR MR MRMRMR MRMRMRMRMRMR MR MRMRMR MR MR MRMR MR MR MRMR MR MRMRMR MRMRMRMRMR MR MRMRMR MR MR MR MR MR MR MR MR MR MR MR SFSF SF SFSF KGKG KG KG KGKG ND ND ND NDND ND ND NDNDND ND ND ND CS CS CS RG CSCS CS CS CS CS CS CS NDNDNDND ND NDNDND ND ND NDNDND ND CSCS RGRGRG RG RG RGRGRG RG RG RG RGRGRG RG RG RGCS CS CS CSCS CS CS CSCSCS CS CS CS CS CSCSRG RG VD VDVDVD CS VD VD VDVDVD VD VD VDVDVD VM VM VM VM VM VMCSCS CS CS CS CS CS KGKGKG KG KG KG KG KG KG KG KG KG KGKG KG KG KG KG KG KG KGKG VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSFSF SFSFSFSFSFSFSFSF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSF SFSFSFSFSF SFSFSFSF SFSFSF SFSF SF WRWRWRWRWR WR WR WR WR WR WR WR WRWRWR WRWRWRWRWR WR RGRG RG RG RG RG RG RG RG RG RG RGRGRG RG RG RG RG RG RG RG RG RG RG RG RG RGRGRG RGRG RG RG CG MP MP MP MP MP MP MP MP MP MP MP MP MP MP CS CS CS CS CS CS CS CS CS CS CS CS CS CSCS CS CS CS CS CS CS CS CSCS CS CG CGCGCGCGCGCGCGCGCG CGCGCG CG CG MP MP MP MP CGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCG CG CG CG CG CG CG CG CG CG CG CGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCGCG CG CG CGCGCGCGCG CGCGCGCGCGCG CGCG NDNDNDNDNDNDNDNDNDNDND ND ND ND ND ND NDNDND ND ND NDND NDNDNDNDNDNDNDND ND ND ND ND VD VDVD VDVD VD VD VD VD VDVDVD VD VD VDVD VDVD VD VD VD VD VD RG RG BUS BAY 5 BUS BAY 2 BUS BAY 4 BUS BAY 1 BUS BAY 2 BUS BAY 8 BUS BAY 7 BUS BAY 3 BUS BAY 6 BUS BAY 4 BUS BAY 5 CORE FACILITY SECURITY GENERATOR HIGH POWER LINE TOWERSBUS LAYOVER REFUSE AND RECYCLING AREA PARATRANSIT SHELTER KCM SHELTER 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - A - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 4 : 4 6 : 0 9 P M 1" = 40'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ASP201 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE SITE PLAN TRANSIT CENTERJCDH CC JC DH CC 12/10/2024 399ISSUED FOR BID12/10/2024 SCALE IN FEET 40 20 0 40 80 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 1 1 1 06/13/2025 ADDENDUM #1 1 1 1 AT S APPLICABLE CODES AND STANDARDS REMARKS: CONSTRUCTION TYPE: VB CODE REVIEW 1. THE TRANSIT CENTER CONSISTS OF A CENTER BOARDING PLATFORM THAT HAS 8 BUS BAYS. BENCHES, WINDSCREENS ARE PROVIDED. THREE CANOPIES ARE PROVIDED FOR WEATHER PROTECTION. THE EAST CANOPY IS DESIGNED TO BE CLEAR FROM OVERHEAD POWER LINE EASEMENT. WINDSCREEN WALLS ARE 8 FT HIGH IN BETWEEN OPEN CANOPY COLUMNS. 2. CORE FACILITY IS COMPOSED OF SECURITY, STORAGE, COMFORT STATIONS, JANITOR ROOMS, LACTATION ROOM, TELECOM ROOM AND ELECTRICAL ROOM. IT IS A STEEL FRAMED STRUCTURE WITH CMU VENEER. INSULATED PER SEATTLE ENERGY CODE. PROPERTY INFORMATION OWNERS CONTACT INFORMATION AUTHORITY HAVING JURISDICTION: SOUND TRANSIT 401 S. JACKSON STREET, SEATTLE WASHINGTON 98104 BUILDING DESCRIPTIONS ADDRESS: 780 RAINIER AVENUE SOUTH,RENTON, WA 98055 ZONE CODE: PUBLIC TRANSIT CENTER LAND USE CODE: 8862 -MISCELLANEOUS -GOVERNMENT OWNED PROPERTY -TRANSPORTATION - GENERAL PARCEL NUMBERS 1923059035, 1923059063, 1923059068, 1923059074 LEGAL DESCRIPTION FOR PARCEL No. 1923059035: LOT 2 LESS HWY PER DEED #20110812001717 OF RENTON LLA #LUA-02-025-LLA REC 20020515900009 LOCATED IN NW 1/4 OF NE 1/4 FOR PARCEL No. 1923059063: POR OF NW QTR OF NE QTR STR 19-23-05 DAF: BEG AT NE COR SD SEC 19 TH N 89-50-24 W ALG N LN SD NE QTR 2179.38 FT TH S 00-09-36 W AT R/A TO SD N LN 510.35 FT TO TPOB TH CONTG S 00-09-36 W 260.0 FT TO NLY MGN OF BN RR R/W (FORMERLY NP RR R/W) TH N 77-20-05 E ALG SD MGN 414.00 FT TO ORIGINAL C/L OF BONNEVILLE POWER TRANSMISSION LINE R/W TH N 00-29-24 W ALG SD C/L 168.13 FT TO PT FROM WCH TPOB BEARS N 89-50-24 W TH N 89-50-24 W TO TPOB LESS W 0.98 FT THOF FOR PARCEL No. 1923059068: POR OF ABANDONED BN RR R/W (FORMERLY NP RR) LY WLY OF FOLG DESC LN: BEG AT NXN OF ORIGINAL C/L OF BONNEVILLE POWER TRANSMISSION LINE R/W WITH N LN OF NE QTR STR 19-23-05 SD PT BEING 1783.40 FT W OF NE COR SD SEC 19 LESS HWY PER DEED #20110812001717 FOR PARCEL No. 1923059074: POR OF PUGET SOUND POWER & LIGHT CO R/W IN NE QTR STR 19-23-05 LY NORTH OF NLY MGN OF S GRADY WAY & WLY OF FOLG DESC LN -BEG AT NXN OF ORIGINAL C/L OF BONNEVILLE POWER TRANSMISSION LINE R/W SD PT BEING 1783.40 FT W OF NE COR SD SEC 19 TH S 00-29-24 W ALG SD C/L TO NLY LN SD S GRADY WAY LESS POR LY WLY OF ELY LN OF RAINIER AVE S (STATE RD NO 167) & LESS POR CONDEMNED BY STATE OF WASHINGTON IN SCC NO 861445 LESS HWY PER DEED #20110812001717 ZONING DISTRICT COMMERCIAL ARTERIAL (CA) LAND USE DESIGNATION: MIXED USE (CMU) OVERLAY DISTRICT: URBAN DESIGN DISTRICT D DEVELOPMENT STANDARDS: RENTON MUNICIPAL CODE ( RMC) TITLE IV -DEVELOPMENT REGULATIONS ALLOWABLE BLDG HT: 50 FT PROPOSED STRUCTURES: 28 FT (TRANSIT CENTER), 15 FT (CORE FACILITY), AND 8 FT (GENERATOR) THE 15 FT INCREASE IS ALLOWED FOR BUILDINGS WITH PITCH ROOF FOR 60% OR MORE OF THE STRUCTURE. GIVEN THE FUNCTION OF THE TRANSIT CENTER AND ITS SUPPORT FACILITIES, THE INTENT IS TO MEET THE CODE REQUIREMENTS THROUGH FACADE DESIGN AND ARTICULATION. CITY OF RENTON ZONING AND LAND USE: 2021 IBC (WAC 51-50) 2021 IMC (WAC 51-50) 2021 UPC (WAC 51-56 & 51-57) 2020 NEC (NFPA 70) 2021 WASHINGTON STATE ENERGY CODE (WAC 51-51C) OPEN STRUCTURES BUS PLATFORM (SECTOR A, B, C):9,396 SF GENERATOR: 470 SF CORE FACILITY BUILDING:2,651 SF BUILDING/ STRUCTURE AREA: VB SINGLE OCCUPANCY MINIMUM CONSTRUCTION TYPE PER IBC 2021 & WAC 51-50, SECTION 602, PER TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS: BUILDING ELEMENTS FOR TYPE VB: PRIMARY STRUCTURAL FRAME 0 HR NON-BEARING WALLS AND PARTITION INTERIOR 0 HR FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS 0 HR ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS 0 HR TABLE 602, FIRE SEPARATION BY DISTANCE EXTERIOR WALLS TYPE VB, 0 HR, DISTANCE EQUAL OR LARGER THAN 10 FT. FIRE ALARM SYSTEM: ALLOWABLE HEIGHT (TABLE 504.3):40 FEET ALLOWABLE STORIES (TABLE 504.4):2 STORIES TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE, TYPE V-B CONSTRUCTION (NON SPRINKLERED) OCCUPANCY B:2 STORIES ALLOWABLE BUILDING STORY: 1 STORY PROPOSED BUILDING AREA: 2,651 SF < 9,000 SF (IBC TABLE 506.2) ALLOWABLE BUILDING AREA, NS, Aa=At + (NS x If). FRONTAGE INCREASE IS NOT NEEDED FOR THIS ALLOWABLE AREA CALCULATION. NOT PROVIDED AUTOMATIC SPRINKLER SYSTEM IS NOT PROVIDED PER RMC TITLE IV SECTION 903.2.4 FOR BUILDING NOT OVER 5,000 SQUARE FEET. ALLOWABLE HEIGHT AND AREA (TABLE 504 & 506) 1. FIRE EXTINGUISHERS ARE LOCATED PER NFPA10 2. PORTABLE FIRE EXTINGUISHERS LOCATED AT ANCILLARY SPACES -PROVIDE CARBON DIOXIDE FIRE EXTINGUISHERS AT ALL ELECTRICAL ROOMS. 3. INTERIOR FINISH MATERIALS ARE IN COMPLIANCE WITH FLAME SPREAD RATING PER CHAPTER 8 2017 MATERIAL FLAME SPREAD RATING FIRE RETARDANT TREATED WOOD CLASS A GYP BOARD CLASS A METAL PANEL CLASS A CONCRETE CLASS A CONCRETE MASONRY UNITS CLASS A -# OF OCCUPANTS EXIT TOTAL ALLOWABLE BUILDING AREA (506.2) ALLOWABLE: 6,000 SF, OCC A-3, TYPE VB CONSTRUCTION (NON SPRINKLERED) 9,000 SF, OCC B TYPE VB CONSTRUCTION (NON SPRINKLERED) 5,000 SF, OCC U TYPE VB CONSTRUCTION (NON SPRINKLERED) CORE FACILITY BUILDINGOPEN STRUCTURES TABLE 1006.2.1 SPACE WITH ONE EXIT ALLOWABLE DISTANCE:100 FEET, OCCUPANT LOAD <30, NS. PROVIDED:27 FEET TABLE 1017.2. EXIT ACCESS TRAVEL DISTANCE ALLOWABLE DISTANCE:200 FT, A-3 OCCUPANCY, NS. 300 FT, U OCCPANCY, NS. PROVIDED: N/A AT BUS PLATFORM, OPEN STRUCTURE. 37 FT < 300 (GENERATOR ENCLOSURE), U OCC PER SECTION 1006.2.1 EXCEPTION 3, UNOCCUPIED MECHANICAL ROOMS AND PENTHOUSES ARE NOT REQUIRED TO COMPLY WITH COMMON PATH OF EGRESS TRAVEL DISTANCE MEASUREMENT OCCUPANCY (IBC SECTION 3) BUS PLATFORM:A-3 (303.4 ASSEMBLY GROUP) WAITING AREAS IN TRANSPORATION TERMINAL GENERATOR:U (312.1 UTILITY AND MISCELLANEOUS GROUP) ALLOWABLE HEIGHT ABOVE GRADE PLANE (TABLE 504.3) ALLOWABLE:40 FT, OCCUPANCY A, B, U PROVIDED:23 FT (BUS PLATFORM) 11 FT APPROX. (GENERATOR) PROVIDED: BUS PLATFORM -2,436 SF (SECTOR A), 1,740 SF (B), 5,220 SF (C)< 6,000 GENERATOR -470 SF < 5,000 907.2.2 GROUP B CORE FACILITY PLATFORM WEST (SECTOR A) PLATFORM CENTER WEST (SECTOR B) PLATFORM EAST PLATFORM CENTER EAST (SECTOR C) GENERATOR PAD REFUSE AND RECYCLING AREA KCM SHELTER PARATRANSIT SHELTER 31 221111 554 5 27' 14' 23' 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - A - v 2 0 2 0 . r v t 6/ 3 / 2 0 2 5 5 : 2 7 : 4 0 P M BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ASZ201 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE LIFE SAFETY PLAN AND CODE INFORMATION TRANSIT CENTERJCDH CC JC DH CC 12/10/2024 400ISSUED FOR BID12/10/2024 SCALE: 1" = 80'-0" LIFE SAFETY SITE PLAN CORE FACILITY OCCUPANT LOAD TABLE NO.NAME AREA TYPE OCC. # BT120L1200 SECURITY BLDG 257 SF B 3 BT120L1201 SEC STORAGE 69 SF B 1 BT120L1202 LACTATION ROOM 112 SF B 2 BT120L1203 JANITOR 113 SF B 2 BT120L1204 OPERATOR RESTROOM 74 SF B 1 BT120L1205 OPERATOR RESTROOM 74 SF B 1 BT120L1206 OPERATOR RESTROOM 75 SF B 1 BT120L1207 OPERATOR RESTROOM 74 SF B 1 BT120L1208 TELECOM 409 SF B 5 BT120L1209 ELECTRICAL 351 SF B 4 BT120L1210 STORAGE 1 450 SF B 5 BT120L1500 GENERATOR Not Enclose d TOTAL:26 SCALE IN FEET 80 16004080 N SCALE IN FEET 8 1616 320 N SCALE: 1/16" = 1'-0" CORE FACILITY PLAN N SCALE: 1/16" = 1'-0" GENERATOR PAD 1 1 1 1 1 1 1 1 1 1 1 1 06/13/2025 ADDENDUM #1 1 1 1 1.A 1.B 1.C 1.E 1.D 1.F 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.15 1 BT120-APP212 1 BT120-APP213 1 BT120-APP214 1 BT120-APP215 BUS BAY 1 BUS BAY 2 BUS BAY 3 BUS BAY 8 BUS BAY 4 BUS BAY 7 BUS BAY 6 BUS BAY 5 STRIDE PYLON STRIDE PYLON 1.16 1.17 STRIDE BUS BAY STRIDE BUS BAY 25.040 26.554 PARATRANSIT SHELTER N:175416.72 E:1298223.62 N:175386.95 E:1298289.18 N:175311.72 E:1298310.88 N:175299.42 E:1298325.79 N:175336.21 E:1298400.93 N:175316.37 E:1298444.64 N:175307.10 E:1298658.85 N:175307.96 E:1298490.85 N:175306.68 E:1298739.18 N:175306.77 E:1298722.51 TRASH RECEPTACLES, TYP.TRASH RECEPTACLES, TYP. CL( OF COLUMN) CL( OF COLUMN) CL( OF COLUMN)CL( OF COLUMN) CL( OF COLUMN) CL( OF COLUMN)CL( OF COLUMN) CL( OF COLUMN) CL( OF COLUMN) CL( OF COLUMN) 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - A - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 4 : 4 6 : 1 3 P M 1" = 30'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APP211 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE OVERALL PLAN PLATFORMJC DH CC JC DH CC 12/10/2024 401ISSUED FOR BID12/10/2024 SCALE IN FEET 15 3030 600 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 1 1.A 1.B 1.C A BT120-AEX712 1.1 1.2 1.3 1.4 A BT120-AEX711 B BT120-AEE812 A BT120-AEE812 4' - 0 " 14 ' - 0 " 14 ' - 0 " 4' - 0 " 24'-0"24'-0"24'-0" 36 ' - 0 " 4' - 0 " 11 ' - 0 " 6' - 0 " 11 ' - 0 " 4' - 0 " A BT120-AEE811 MA T C H L I N E : SE E D W G BT 1 2 0 -AP P 2 1 3 3' - 9 " 1' - 2 " DRAINAGE DOWNSPOUT OVERFLOW DOWNSPOUT 1 BT120-AED903 10'-0"6'-0" 10'-0"6'-0" 5' - 0 " TICKET VENDING MACHINE WINDSCREEN BENCH-2, TYP. WINDSCREEN STRIDE PYLON BUS BAY FLAG POLE WARNING TILE, PT-2, TYP. SIGN. CENTER ON GRID LINE 1.B 9' - 0 " 9' - 0 " 19'-0" TYP. 8'-0" METAL COLUMN COVER, ON BOTH SIDES OF COLUMN, C-1, TYP. 5'-0"CL 1 BT120-AED901 1 BT120-AED901 CL 3'-7" 1'-8" 5'-0"2'-9" LEAN RAIL, LR-1 TYP. BOLLARD, TYP. 1' WIDE EXTERIOR CONCRETE FINISH. MEDIUM ETCHED, INTEGRAL COLOR, CIP-3, TYP. ACCESSIBLE BOARDING AREA, PC-2 1 BT120-AID906 TRASH/ RECYCLING RECEPTACLES . . .. RAILING, GDR-9 . .. . . . BUS BAY 1 HYDRANT BOX 12'-8 1/2" 10 ' - 6 " 2'-6" 2'-6" 2'- 6 " HYDRANT BOX 39' - 8" 1' - 6" 7' - 0 " 3' - 6"9' - 6" 7' - 0 " SMART CARD READER PUSH BUTTON AUDIO SMART CARD READER CIP-1, TYP. 34'-0"CL 7'-0"12'-0" CL CL CL CL CL 8' - 4 " 2' - 6 " 2' - 6 " CL 3'-9" 1' - 0 " 6' - 3 " CL CABINET, TYP JUNCTION BOX, TYP CL CL 10'-6" 7' - 0 " CL CL 13'-6" 5" CL CL CL CL CL CL 2' - 6 " ADA PAVER, (PC-2) STRIDE PYLON (BY OTHERS) BENCH -2, TYP. UNO ELECTRICAL CABINET TVM -TICKET VENDING MACHINE (BY OTHERS) TRASH/ RECYCLING RECEPTACLES ORCA/SMART CARD READER (BY OTHERS) TACTILE WARNING (PT-2) BUS FLAG POLE TYP (BY OTHERS) LEGEND LIGHT POLE GUARDRAIL (GDR-9) ELECTRICAL MANHOLE LEAN RAIL (LR-1) EXTERIOR CONCRETE FINISH. MEDIUM ETCHED, INTEGRAL COLOR, CIP-A BOLLARD CLEARANCE ZONE PUSH BUTTON AUDIO (BY OTHERS) 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - A - v 2 0 2 0 . r v t 6/ 2 / 2 0 2 5 4 : 4 6 : 1 5 P M 1/8" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APP212 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE PLATFORM PLAN PLATFORM - SECTOR A JC DH CC JC DH CC 12/10/2024 402ISSUED FOR BID12/10/2024 SCALE IN FEET 4 0 88 16 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 1 1.A 1.B1.B 1.C 1.5 1.6 1.7 MA T C H L I N E : SE E D W G BT 1 2 0 -AP P 2 1 2 M A T C H L I N E : S E E D W G B T 1 2 0 - A P P 2 1 4 BUS BAY 2 BUS BAY 8 A BT120-AEE813 24'-0"24'-0" TYP 9'-0" TYP 9'-0" 11'-0" 3'-6" WINDSCREEN BENCH-2, TYP. STRIDE PYLON BUS BAY FLAG POLE, TYP. WARNING TILE, PT-2, TYP. LEAN RAIL, LR-1, TYP. TVM TRASH/ RECYCLING RECEPTACLES, TYP. METAL COLUMN COVER, ON BOTH SIDES OF COLUMN, C-1, TYP. 6'-0" 1 BT120-AED901 CL 4'-6"1'-6" 1 BT120-AED901 CL 1'-6" 4'-6" 1' WIDE EXTERIOR CONCRETE FINISH. MEDIUM ETCHED, INTEGRAL COLOR, CIP-3, TYP. ACCESSIBLE BOARDING AREA, PC-2, TYP. 1 BT120-AID907 . . . . .. B BT120-AEE813 4'-0" 14'-0" 14'-0" 4'-0" V.I.P. 10'-9" 10'-6" 7'-6" PARATRANSIT SHELTER HYDRANT BOX 2 BT120-AID907 1 BT120-AID903 A BT120-AEE816 B BT120-AEE816 C BT120-AEE816 MIRROR MIRROR MIRROR 2 BT120-APP216 CIP-1, TYP. 7'-9" 5'-0" 5'-0" 1'-9" 1'-9" 8'-7" 14'-0"3'-4" CL CL CL CL CL CL CL 6'-0"7'-6" CL CL CL 1'-2" 4'-6" 12'-0" CL CL JUNCTION BOX, TYP CABINET, TYP CL CL 2'-8" 3'-8" CL CL 1'-3" 2'-2" 1'-6" CL2'-9" ADA PAVER, (PC-2) STRIDE PYLON (BY OTHERS) BENCH -2, TYP. UNO ELECTRICAL CABINET TVM -TICKET VENDING MACHINE (BY OTHERS) TRASH/ RECYCLING RECEPTACLES ORCA/SMART CARD READER (BY OTHERS) TACTILE WARNING (PT-2) BUS FLAG POLE TYP (BY OTHERS) LEGEND LIGHT POLE GUARDRAIL (GDR-9) ELECTRICAL MANHOLE LEAN RAIL (LR-1) EXTERIOR CONCRETE FINISH. MEDIUM ETCHED, INTEGRAL COLOR, CIP-A BOLLARD CLEARANCE ZONE PUSH BUTTON AUDIO (BY OTHERS) 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:16 PM 1/8" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APP213 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE PLATFORM PLAN PLATFORM - SECTOR B JC DH CC JC DH CC 12/10/2024 403ISSUED FOR BID12/10/2024 SCALE IN FEET 4 0 88 16 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 1 1 1.E 1.D 1.F 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.15 MATCH LINE: SEE DWG BT120-APP213 MA T C H L I N E : SE E D W G BT 1 2 0 -AP P 2 1 5 BUS BAY 7 BUS BAY 3 BUS BAY 6 A BT120-AEE814 A BT120-AEE815 B BT120-AEE814 B BT120-AEE815 24'-0"24'-0"24'-0"24'-0"24'-0"24'-0"24'-0" 9'-0" 9'-0" 9'-0" 9'-0" 1 BT120-AED901 4'-0" 14'-0" 14'-0" 4'-0" 3'-6" 3'-6" METAL COLUMN COVER, ON BOTH SIDES OF COLUMN, C-1, TYP. TYP. 8'-0" TRASH/ RECYCLING RECEPTACLES, TYP. WINDSCREEN BENCH-2, TYP. BUS BAY FLAG POLE, TYP. WARNING TILE, PT-2, TYP. LEAN RAIL, LR-1, TYP. BUS BAY FLAG POLE CL 5'-0"1'-6" 1 BT120-AED901 CL 5'-0" CL 5'-0" CL 7"5'-0" 1'-9" CL 1 BT120-AED901 5'-0"1'-6" CL 1'-6"5'-0" CL ACCESSIBLE BOARDING AREA, PC-2, TYP. . .. WARNING TILE, PT-2, TYP. 12' - 6" 1'-9" BENCH-1 1' WIDE EXTERIOR CONCRETE FINISH. MEDIUM ETCHED, INTEGRAL COLOR, CIP-3, TYP. HYDRANT BOX 6' - 6" 8' - 0" 4'-7"3'-9"6'-0" 3'-9"9'-9" 6'-6" 3'-10" 6'-4" 3'-0" 3'-6" CL CL CL CL CL CL JUNCTION BOX, TYP CL CL CL CL 5'-9" 11" CL CL CL CL 11'-6" 11" 5'-4" 2'-8" 5'-8" 6"CL 6"CL CL CL ADA PAVER, (PC-2) STRIDE PYLON (BY OTHERS) BENCH -2, TYP. UNO ELECTRICAL CABINET TVM -TICKET VENDING MACHINE (BY OTHERS) TRASH/ RECYCLING RECEPTACLES ORCA/SMART CARD READER (BY OTHERS) TACTILE WARNING (PT-2) BUS FLAG POLE TYP (BY OTHERS) LEGEND LIGHT POLE GUARDRAIL (GDR-9) ELECTRICAL MANHOLE LEAN RAIL (LR-1) EXTERIOR CONCRETE FINISH. MEDIUM ETCHED, INTEGRAL COLOR, CIP-A BOLLARD CLEARANCE ZONE PUSH BUTTON AUDIO (BY OTHERS) 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:17 PM 1/8" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APP214 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE PLATFORM PLAN PLATFORM - SECTOR C JC DH CC JC DH CC 12/10/2024 404ISSUED FOR BID12/10/2024 SCALE IN FEET 4 0 88 16 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 1 ADA PAVER, (PC-2) STRIDE PYLON (BY OTHERS) BENCH -2, TYP. UNO ELECTRICAL CABINET TVM -TICKET VENDING MACHINE (BY OTHERS) TRASH/ RECYCLING RECEPTACLES ORCA/SMART CARD READER (BY OTHERS) TACTILE WARNING (PT-2) BUS FLAG POLE TYP (BY OTHERS) LEGEND LIGHT POLE GUARDRAIL (GDR-9) ELECTRICAL MANHOLE LEAN RAIL (LR-1) EXTERIOR CONCRETE FINISH. MEDIUM ETCHED, INTEGRAL COLOR, CIP-A BOLLARD CLEARANCE ZONE PUSH BUTTON AUDIO (BY OTHERS) 1.E 1.D 1.F 1.15 MA T C H L I N E : SE E D W G BT 1 2 0 -AP P 2 1 4 BUS BAY 5 BUS BAY 4 9'-0" 9'-0" 9'-0" 9'-0" BUS BAY 6 1.16 1.17 63'-8"16'-8" 3'-6" BUS BAY FLAG POLE WARNING TILE, PT-2, TYP. METAL COLUMN COVER, ON BOTH SIDES OF COLUMN, C-1, TYP. TYP. 8'-0" 1 BT120-APP216 DROP OFF BUS BAY ACCESSIBLE BOARDING AREA, PC-2 . . . 4'-0" 14'-0" 14'-0" 4'-0" ST BIKE LOCKERS, FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR TRASH/ RECYCLING RECEPTACLES, TYP. HYDRANT BOX HYDRANT BOX 1' WIDE EXTERIOR CONCRETE FINISH. MEDIUM ETCHED, INTEGRAL COLOR, CIP-3, TYP. 6' - 6" 6' - 0" 3' - 0" 15' - 6" 6' - 6" 50' - 4"2' - 2"7' - 1" CL CL CL CL CL 11'-8" 3'-3" 5'-0" 3'-0" CL CL CL CL CL 1'-9" 5'-2" 4'-0" 7'-7" 12'-0"3'-0"5'-0" CL CL CL JUNCTION BOX, TYP CL CL CL CL 4'-10" 3'-0" 4'-6" 4'-10" HANDHOLES, TYP LIGHT POLE, TYP LIGHT POLE, TYP CES 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:18 PM 1/8" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APP215 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE PLATFORM PLAN PLATFORM - SECTOR D JC DH CC JC DH CC 12/10/2024 405ISSUED FOR BID12/10/2024 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE IN FEET 4 0 88 16 1 06/13/2025 ADDENDUM #1 1 1 1 1 1 ADA PAVER, (PC-2) STRIDE PYLON (BY OTHERS) BENCH -2, TYP. UNO ELECTRICAL CABINET TVM -TICKET VENDING MACHINE (BY OTHERS) TRASH/ RECYCLING RECEPTACLES ORCA/SMART CARD READER (BY OTHERS) TACTILE WARNING (PT-2) BUS FLAG POLE TYP (BY OTHERS) LEGEND LIGHT POLE GUARDRAIL (GDR-9) ELECTRICAL MANHOLE LEAN RAIL (LR-1) EXTERIOR CONCRETE FINISH. MEDIUM ETCHED, INTEGRAL COLOR, CIP-A BOLLARD CLEARANCE ZONE PUSH BUTTON AUDIO (BY OTHERS) 1.E 1.16 1.17 A BT120-AEE816 B BT120-AEE816 C BT120-AEE816 16'-8" TYP. 8'-0" BENCH-2, TYP. LEAN RAIL, LR-1, TYP. 4'-2"8'-4" 2'-8" E BT120-AEX714 CL CL 8'-4" 3'-0" CL ROOF OUTLINE ABOVE, PP-2 CL CL A BT120-AEE816 B BT120-AEE816 C BT120-AEE816 MIRROR MIRROR SEE BT120-APP211 FOR NORTHING AND EASTING TRASH RECEPTACLES, TYP. 16'-8" 8'-4"8'-4" CL ROOF OUTLINE ABOVE, PP-2 CL CL 3'-0" BENCH-2, TYP. LEAN RAIL, LR-1, TYP. 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:20 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APP216 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE ENLARGED SHELTER PLANS PLATFORM - SECTOR D JC DH CC JC DH CC 1/2" = 1' -0" 12/10/2024 406ISSUED FOR BID12/10/2024 SCALE IN FEET 1 02 2 4 SCALE: 1/2" = 1'-0" BT120-APP215 ENLARGED KCM SHELTER 1 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE: 1/2" = 1'-0" BT120-APP213 ENLARGED PARATRANSIT SHELTER 2 1 06/13/2025 ADDENDUM #1 1 1 1 1 1 P 1.A 1.B 1.C 1.E 1.D 1.F 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.15 1 BT120-ARP312 1 BT120-ARP313 1 BT120-ARP314 APPROX. ROOF AREA: 84' x 15' = 1260SF -UPPER 84' x 14' = 1176SF -LOWER APPROX. ROOF AREA: 60' x 15' = 900SF -UPPER 60' x 14' = 840SF -LOWER APPROX. ROOF AREA: 180' x 15' = 2700SF -UPPER 180' x 14' = 2520SF -LOWER 1.16 1.17 2 BT120-ARP314 STRIDE PYLON CANOPY COLUMN, TYP.SHELTER BUS BAY FLAG POLE, TYP. BUS BAY, TYP. BIKE LOCKERS PARATRANSIT SHELTER 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:21 PM 1" = 30'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ARP311 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE OVERALL ROOF PLAN PLATFORMJC DH CC JC DH CC 12/10/2024 407ISSUED FOR BID12/10/2024 SCALE IN FEET 15 3030 600 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 1 1 1.A 1.B 1.C A BT120-AEX712 1.1 1.2 1.3 1.4 A BT120-AEX711 2 BT120-APD101 1/ 2 " / 1 2 " 3'-6" 3'-6" HORIZONTAL LIFE LINE FALL RESTRAINT SYSTEM, TYP. PORTABLE LADDER TIE-OFF 14'-0" 14'-0" 24'-0"24'-0"24'-0" A BT120-AED916 HORIZONTAL LIFE LINE FALL RESTRAINT SYSTEM ANCHOR ATTACHED TO ROOF STRUCTURE BELOW, TYP. TYP. 6'-0" 4'-6" 3/ 4 " / 1 2 " PROVIDE BIRD CONTROL DEVICE BCD-1 ALONG THE CANOPY EDGES, TYP. 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:22 PM 1/8" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ARP312 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE PLATFORM ROOF PLAN PLATFORM - SECTOR A JC DH CC JC DH CC 12/10/2024 408ISSUED FOR BID12/10/2024 SCALE IN FEET 4 0 88 16 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 1 06/13/2025 ADDENDUM #1 1 1 1 1.A 1.B 1.C 1.5 1.6 1.7 CL 4'-6" 3'-6" 3'-6" HORIZONTAL LIFE LINE FALL RESTRAINT SYSTEM, TYP. PORTABLE LADDER TIE-OFF STRIDE PYLON A BT120-AED916 HORIZONTAL LIFE LINE FALL RESTRAINT SYSTEM ANCHOR ATTACHED TO ROOF STRUCTURE BELOW, TYP. TYP. 6'-0" PROVIDE BIRD CONTROL DEVICE BCD-1 ALONG THE CANOPY EDGES, TYP. 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:23 PM 1/8" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ARP313 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE PLATFORM ROOF PLAN PLATFORM - SECTOR B JC DH CC JC DH CC 12/10/2024 409ISSUED FOR BID12/10/2024 SCALE IN FEET 4 0 88 16 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 1 06/13/2025 ADDENDUM #1 1 1 1 1.E 1.D 1.F 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.15 3'-6" 3'-6" PORTABLE LADDER TIE-OFF A BT120-AED916 4'-6" HORIZONTAL LIFE LINE FALL RESTRAINT SYSTEM ANCHOR ATTACHED TO ROOF STRUCTURE BELOW, TYP. TYP. 6'-0" PROVIDE BIRD CONTROL DEVICE BCD-1 ALONG THE CANOPY EDGES, TYP. 1.E 1.D 1.F 1.16 1.17 1/ 2 " / 1 2 " TYPICAL FOR STAND ALONE KCM SHELTER AND PARATRANSIT SHELTER 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:24 PM 1/8" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ARP314 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE PLATFORM ROOF PLAN PLATFORM - SECTOR C JC DH CC JC DH CC 12/10/2024 410ISSUED FOR BID12/10/2024 SCALE IN FEET 4 0 88 16 SCALE: 1/8" = 1'-0" ENLARGED PLATFORM ROOF - SECTOR C 1 BT120-ARP311 SCALE: 1/8" = 1'-0" ENLARGED PLATFORM ROOF SECTOR D - SHELTER 2 BT120-ARP311 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 1 1 1 P P 1.A 1.B 1.C 1.1 1.2A BT120-AEX711 ACCESS PANEL, TYP. J BT120-AED902 SYSTEM CAMERA, TYP. LIGHTING, TYP. ST SIGN, TYP. 1.A 1.B 1.C 1.1 1.2A BT120-AEX711 HORIZONTAL LIFE LINE FALL RESTRAINT SYSTEM, TYP. PORTABLE LADDER TIE-OFF A BT120-AED916 1.31.4 BUS FLAG AT FOREGROUND TICKET VENDING MACHINE PUSH BUTTON AUDIO SMART CARD READER ST SIGNAGE, TYP. CLERESTORY FOR ART GLASS INSTALLATION APA-1, ALUMINUM STOREFRONT FRAME, SF-1, TYP. METAL COLUMN COVER, C-1, TYP A BT120-AID903 1 ST SIGN 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:26 PM 1/4" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN C. CHEANG C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APD101 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE ENLARGED PLATFORM PLANS & ELEVATION PLATFORMJC DH CC JC DH CC 12/10/2024 411ISSUED FOR BID12/10/2024 SCALE: 1/4" = 1'-0" BT120-ACP212 PARTIAL REFLECTED CEILING PLAN - WEST 1 SCALE: 1/4" = 1'-0" PARTIAL ENLARGED PLATFORM ROOF - WEST 2 BT120-ARP312 SCALE: 1/4" = 1'-0"BT120-AEE812 PARTIAL ELEVATION AT CANOPY - BUS BAY 1 A SCALE IN FEET 2 44 80 1 06/13/2025 ADDENDUM #1 11 1.A 1.B 1.C 1.E 1.D 1.F 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.15 BUS BAY 1 BUS BAY 2 BUS BAY 3 BUS BAY 8 BUS BAY 4 BUS BAY 7 BUS BAY 6 BUS BAY 5 1 BT120-ANP212 1 BT120-ANP213 1 BT120-ANP214 1 BT120-ANP215 1.16 1.17 FACILITY TYPE A7 STATION IDENTIFICATION TYPE B2 / TYPE D2 PLATFORM IDENTIFICATION TYPE C6 CUSTOMER INFORMATION TYPE F3 SIGNATE TYPES (NTS): 7'-11" 3'-0"3'-0" CL CL 1'-0" 4'-0" 2'-0" 3'-10" 3'-10" 2'-0" 3'-9" COLUMN WINDSCREEN FRAME SEE B/ BT120-AED915 FOR MOUNTING DETAIL SEE A/ BT120-AED914 FOR MOUNTING DETAIL SEE A/ BT120-AED914 FOR MOUNTING DETAIL SEE D/ BT120-AED914 FOR MOUNTING DETAIL TYPE C3 CUSTOMER INFORMATION SEE C/ BT120-AED914 FOR MOUNTING DETAIL 2'-0" 3'-10" 3'-9" TYPE B6 CUSTOMER INFORMATION SEE C/ BT120-AED914 FOR MOUNTING DETAIL 1'-2" 28 1/2"28 1/2" 6'-4" 6'-4" 1'-2" CL 10'-2" 9'-0" MIN (D2) 8'-2" MIN, TYP 9'-0" 1'-4" 4'-0" DIRECTIONAL TYPE D14 2'-4" 1'-5" C1 - DUAL SIGNS FACILITY TYPE E1/E6 SEE E/ BT120-AED914 FOR MOUNTING DETAIL TYPE R3 STAINLESS STEEL RAILINGS, GDR-9 REGULATORY EQ EQ 2'-6" MOUNTING DETAIL PROVIDE BY SOUND TRANSIT 10'-0" TYPE F1 8'-0" FACILITY SEE C/ BT120-AED915 FOR MOUNTING DETAIL 1. SEE CIVIL DRAWINGS BT120-CMP100 TO BT120-CMP205 FOR SITE SIGNAGE, AND TYPE R SIGNS THAT ARE OUTSIDE OF BUS PLATFORM AREA. 2. BUILDING INFORMATION SIGNAGE IS INCLUDED IN THIS CONTRACT. FOR BUILDING INFORMATION SIGNAGE REFER TO SPECIFICATION SECTION 10 14 13 -BUILDING INFORMATION SIGNAGE. ALL OTHER SIGNAGE, INCLUDING SIGNAGE PANELS, INTEGRAL PENDANTS, INTEGRAL POLES, INTEGRAL MOUNTING BRACKETS, AND FASTENERS SHALL BE PROVIDED AND INSTALLED BY SIGNAGE INSTALLER UNDER A SEPARATE CONTRACT. 3. FOR PLATFORM SIGNAGE MOUNTING HEIGHTS ARE PROVIDED ON BT120-ANP211 TO 215, TYP. SEE ADDITIONAL INFORMATION ON BT120-AEE ELEVATION DRAWING SERIES. 4. NO MOUNTING DETAIL IN CALLOUT INDICATES ADHESION INSTALLATION. SIGNS WITH (*) TO INDICATE MOUNTING BRACKET BY SOUND TRANSIT. 5. COORDINATE WITH EXTERIOR AND INTERIOR ELEVATIONS FOR LOCATION OF WALL-MOUNTED SIGNS. 6. SIGNS AND ACCESSORIES ARE IN SEPARATE SIGNAGE CONTRACT. THEY ARE GRAPHICALLY SHOWN IN HALF TONE. 7. SIGNS REQUIRING BLOCKING OR ATTACHMENT SUPPORTS OR FOOTINGS UNDER THIS CONTRACT ARE IDENTIFIED BY SIGNAGE MOUNTING DETAILS PROVIDED IN THIS CONTRACT. NOTES: SIGNAGE GRAPHIC LEGEND: SIGNAGE TAG = STA = STA -F2.A -XXX A/BT120-AED9XX SOUND TRANSIT STATION CODE BT120 (SOUTH RENTON TRANSIT CENTER) F2.A =SIGN TYPE . LAYOUT TYPE A/BT120-AED9XX =MOUNTING DETAIL =INDICATION OF PRIMARY SIGN FACE =INDICATION OF SECONDARY SIGN FACE XXX =UNIQUE LOCATION # 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:27 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ANP211 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE OVERALL SIGNAGE PLAN PLATFORMJC DH CC JC DH CC 1"=30'-0" 12/10/2024 412ISSUED FOR BID12/10/2024 SCALE IN FEET 15 3030 600 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 1 1 06/13/2025 ADDENDUM #1 1 1 1 1 1 1.A 1.B 1.C 1.1 1.2 1.3 1.4 MA T C H L I N E : SE E D W G BT 1 2 0 -AP P 2 1 3 BUS BAY 1 MA T C H L I N E : SE E D W G BT 1 2 0 -AN P 2 1 3 CANOPY ABOVE OUTLINE STRIDE PYLON STRIDE DIGITAL SIGN CL 6'-0" 34'-0" 5'-0" 19'-0" 1'-2" PBA (BY OTHERS) SMART CARD, TYP (BY OTHERS) BT120-C3-202 C/BT120-AED914 BT120-C6-203 D/BT120-AED914 BT120-C6-204 D/BT120-AED914 BT120-D2-307 A/BT120-AED914 BT120-A7-001 A/BT120-AED914 BT120-B2-101 A/BT120-AED914 BT120-B2-102 A/BT120-AED914 BT120-E1-401 E/BT120-AED914 BT120-E6-409 E/BT120-AED914 BT120-B2-106 A/BT120-AED914 BT120-C6-205 D/BT120-AED914 BT120-C6-206 D/BT120-AED914 BT120-F3.A-501 B/BT120-AED915 BT120-R3-702 A/BT120-AED915 (*) BT120-R3-701 A/BT120-AED915 (*) BT120-C6-215 D/BT120-AED914 BT120-C6-216 D/BT120-AED914 1. SEE CIVIL DRAWINGS BT120-CMP100 TO BT120-CMP205 FOR SITE SIGNAGE, AND TYPE R SIGNS THAT ARE OUTSIDE OF BUS PLATFORM AREA. 2. BUILDING INFORMATION SIGNAGE IS INCLUDED IN THIS CONTRACT. FOR BUILDING INFORMATION SIGNAGE REFER TO SPECIFICATION SECTION 10 14 13 -BUILDING INFORMATION SIGNAGE. ALL OTHER SIGNAGE, INCLUDING SIGNAGE PANELS, INTEGRAL PENDANTS, INTEGRAL POLES, INTEGRAL MOUNTING BRACKETS, AND FASTENERS SHALL BE PROVIDED AND INSTALLED BY SIGNAGE INSTALLER UNDER A SEPARATE CONTRACT. 3. FOR PLATFORM SIGNAGE MOUNTING HEIGHTS ARE PROVIDED ON BT120-ANP211 TO 215, TYP. SEE ADDITIONAL INFORMATION ON BT120-AEE ELEVATION DRAWING SERIES. 4. NO MOUNTING DETAIL IN CALLOUT INDICATES ADHESION INSTALLATION. SIGNS WITH (*) TO INDICATE MOUNTING BRACKET BY SOUND TRANSIT. 5. COORDINATE WITH EXTERIOR AND INTERIOR ELEVATIONS FOR LOCATION OF WALL-MOUNTED SIGNS. 6. SIGNS AND ACCESSORIES ARE IN SEPARATE SIGNAGE CONTRACT. THEY ARE GRAPHICALLY SHOWN IN HALF TONE. 7. SIGNS REQUIRING BLOCKING OR ATTACHMENT SUPPORTS OR FOOTINGS UNDER THIS CONTRACT ARE IDENTIFIED BY SIGNAGE MOUNTING DETAILS PROVIDED IN THIS CONTRACT. NOTES: SIGNAGE GRAPHIC LEGEND: SIGNAGE TAG = STA = STA -F2.A -XXX A/BT120-AED9XX SOUND TRANSIT STATION CODE BT120 (SOUTH RENTON TRANSIT CENTER) F2.A =SIGN TYPE . LAYOUT TYPE A/BT120-AED9XX =MOUNTING DETAIL =INDICATION OF PRIMARY SIGN FACE =INDICATION OF SECONDARY SIGN FACE XXX =UNIQUE LOCATION # FACILITY TYPE A7 STATION IDENTIFICATION TYPE B2 / TYPE D2 PLATFORM IDENTIFICATION TYPE C6 CUSTOMER INFORMATION TYPE F3 SIGNATE TYPES (NTS): 7'-11" 3'-0"3'-0" CL CL 1'-0" 4'-0" 2'-0" 3'-10" 3'-10" 2'-0" 3'-9" COLUMN WINDSCREEN FRAME SEE B/ BT120-AED915 FOR MOUNTING DETAIL SEE A/ BT120-AED914 FOR MOUNTING DETAIL SEE A/ BT120-AED914 FOR MOUNTING DETAIL SEE D/ BT120-AED914 FOR MOUNTING DETAIL TYPE C3 CUSTOMER INFORMATION SEE C/ BT120-AED914 FOR MOUNTING DETAIL 2'-0" 3'-10" 3'-9" TYPE B6 CUSTOMER INFORMATION SEE C/ BT120-AED914 FOR MOUNTING DETAIL 1'-2" 28 1/2"28 1/2" 6'-4" 6'-4" 1'-2" CL 10'-2" 9'-0" MIN (D2) 8'-2" MIN, TYP 9'-0" 1'-4" 4'-0" DIRECTIONAL TYPE D14 2'-4" 1'-5" C1 - DUAL SIGNS FACILITY TYPE E1/E6 SEE E/ BT120-AED914 FOR MOUNTING DETAIL TYPE R3 STAINLESS STEEL RAILINGS, GDR-9 REGULATORY EQ EQ 2'-6" MOUNTING DETAIL PROVIDE BY SOUND TRANSIT 10'-0" TYPE F1 8'-0" FACILITY SEE C/ BT120-AED915 FOR MOUNTING DETAIL 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:28 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ANP212 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE PLATFORM SIGNAGE PLAN PLATFORM - SECTOR A JC DH CC JC DH CC 1/8" = 1'-0" 12/10/2024 413ISSUED FOR BID12/10/2024 SCALE IN FEET 4 0 88 16 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 1 1 1 1 06/13/2025 ADDENDUM #1 1 1 1 1 1.A 1.B 1.C 1.5 1.6 1.7 MA T C H L I N E : SE E D W G BT 1 2 0 -AN P 2 1 2 M A T C H L I N E : S E E D W G B T 1 2 0 - A N P 2 1 4 BUS BAY 2 BUS BAY 8 CANOPY ABOVE STRIDE DIGITAL SIGNS, TYP. STRIDE PYLON KCM RTIS BT120-TVM DECALS, TYP. 1'-2" 11'-0" 19'-6 1/2" SMARTCARD (BY OTHERS), TYP. PBA (BY OTHERS), TYP. BT120-C6-209 D/BT120-AED914 BT120-C6-207 D/BT120-AED914 BT120-B2-103 A/BT120-AED914 BT120-F3.A-502 B/BT120-AED915 BT120-E1-408 E/BT120-AED914 BT120-E6-411 E/BT120-AED914 BT120-C6-208 D/BT120-AED914 BT120-C6-213 D/BT120-AED914 BT120-B2-107 A/BT120-AED914 BT120-D2-304 A/BT120-AED914 BT120-C3-212 C/BT120-AED914 BT120-E6-410 E/BT120-AED914 BT120-E1-402 E/BT120-AED914 BT120-F3.A-508 E/BT120-AED914 BT120-E6-417 E/BT120-AED914 1. SEE CIVIL DRAWINGS BT120-CMP100 TO BT120-CMP205 FOR SITE SIGNAGE, AND TYPE R SIGNS THAT ARE OUTSIDE OF BUS PLATFORM AREA. 2. BUILDING INFORMATION SIGNAGE IS INCLUDED IN THIS CONTRACT. FOR BUILDING INFORMATION SIGNAGE REFER TO SPECIFICATION SECTION 10 14 13 -BUILDING INFORMATION SIGNAGE. ALL OTHER SIGNAGE, INCLUDING SIGNAGE PANELS, INTEGRAL PENDANTS, INTEGRAL POLES, INTEGRAL MOUNTING BRACKETS, AND FASTENERS SHALL BE PROVIDED AND INSTALLED BY SIGNAGE INSTALLER UNDER A SEPARATE CONTRACT. 3. FOR PLATFORM SIGNAGE MOUNTING HEIGHTS ARE PROVIDED ON BT120-ANP211 TO 215, TYP. SEE ADDITIONAL INFORMATION ON BT120-AEE ELEVATION DRAWING SERIES. 4. NO MOUNTING DETAIL IN CALLOUT INDICATES ADHESION INSTALLATION. SIGNS WITH (*) TO INDICATE MOUNTING BRACKET BY SOUND TRANSIT. 5. COORDINATE WITH EXTERIOR AND INTERIOR ELEVATIONS FOR LOCATION OF WALL-MOUNTED SIGNS. 6. SIGNS AND ACCESSORIES ARE IN SEPARATE SIGNAGE CONTRACT. THEY ARE GRAPHICALLY SHOWN IN HALF TONE. 7. SIGNS REQUIRING BLOCKING OR ATTACHMENT SUPPORTS OR FOOTINGS UNDER THIS CONTRACT ARE IDENTIFIED BY SIGNAGE MOUNTING DETAILS PROVIDED IN THIS CONTRACT. NOTES: SIGNAGE GRAPHIC LEGEND: SIGNAGE TAG = STA = STA -F2.A -XXX A/BT120-AED9XX SOUND TRANSIT STATION CODE BT120 (SOUTH RENTON TRANSIT CENTER) F2.A =SIGN TYPE . LAYOUT TYPE A/BT120-AED9XX =MOUNTING DETAIL =INDICATION OF PRIMARY SIGN FACE =INDICATION OF SECONDARY SIGN FACE XXX =UNIQUE LOCATION # FACILITY TYPE A7 STATION IDENTIFICATION TYPE B2 / TYPE D2 PLATFORM IDENTIFICATION TYPE C6 CUSTOMER INFORMATION TYPE F3 SIGNATE TYPES (NTS): 7'-11" 3'-0"3'-0" CL CL 1'-0" 4'-0" 2'-0" 3'-10" 3'-10" 2'-0" 3'-9" COLUMN WINDSCREEN FRAME SEE B/ BT120-AED915 FOR MOUNTING DETAIL SEE A/ BT120-AED914 FOR MOUNTING DETAIL SEE A/ BT120-AED914 FOR MOUNTING DETAIL SEE D/ BT120-AED914 FOR MOUNTING DETAIL TYPE C3 CUSTOMER INFORMATION SEE C/ BT120-AED914 FOR MOUNTING DETAIL 2'-0" 3'-10" 3'-9" TYPE B6 CUSTOMER INFORMATION SEE C/ BT120-AED914 FOR MOUNTING DETAIL 1'-2" 28 1/2"28 1/2" 6'-4" 6'-4" 1'-2" CL 10'-2" 9'-0" MIN (D2) 8'-2" MIN, TYP 9'-0" 1'-4" 4'-0" DIRECTIONAL TYPE D14 2'-4" 1'-5" C1 - DUAL SIGNS FACILITY TYPE E1/E6 SEE E/ BT120-AED914 FOR MOUNTING DETAIL TYPE R3 STAINLESS STEEL RAILINGS, GDR-9 REGULATORY EQ EQ 2'-6" MOUNTING DETAIL PROVIDE BY SOUND TRANSIT 10'-0" TYPE F1 8'-0" FACILITY SEE C/ BT120-AED915 FOR MOUNTING DETAIL 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:29 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ANP213 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE PLATFORM SIGNAGE PLAN PLATFORM - SECTOR B JC DH CC JC DH CC 1/8" = 1'-0" 12/10/2024 414ISSUED FOR BID12/10/2024 SCALE IN FEET 4 0 88 16 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 1 1 1 1 1 06/13/2025 ADDENDUM #1 1 11 1 1 1.E 1.D 1.F 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.15 MATCH LINE: SEE DWG BT120-ANP213 MA T C H L I N E : SE E D W G BT 1 2 0 -AN P 2 1 5 BUS BAY 7 BUS BAY 3 BUS BAY 6 KCM RTIS KCM RTIS EDGE OF CANOPY ABOVE EDGE OF CANOPY ABOVE KCM RTIS KCM RTIS CL BT120-E6-412 E/BT120-AED914 BT120-E1-407 E/BT120-AED914 BT120-D2-305 A/BT120-AED914 BT120-B2-104 A/BT120-AED914 BT120-C6-210 D/BT120-AED914 BT120-C6-211 D/BT120-AED914 BT120-D2-306 A/BT120-AED914 BT120-B2-105 A/BT120-AED914 BT120-C6-201 D/BT120-AED914 BT120-C6-214 D/BT120-AED914 BT120-E6-413 E/BT120-AED914 BT120-E1-403 E/BT120-AED914 BT120-E1-406 E/BT120-AED914 BT120-E6-414 E/BT120-AED914 BT120-B2-110 C/BT120-AED914 5'-1" NOTES: 1. SEE CIVIL DRAWINGS BT120-CMP100 TO BT120-CMP205 FOR SITE SIGNAGE, AND TYPE R SIGNS THAT ARE OUTSIDE OF BUS PLATFORM AREA. 2. BUILDING INFORMATION SIGNAGE IS INCLUDED IN THIS CONTRACT. FOR BUILDING INFORMATION SIGNAGE REFER TO SPECIFICATION SECTION 10 14 13 -BUILDING INFORMATION SIGNAGE. ALL OTHER SIGNAGE, INCLUDING SIGNAGE PANELS, PENDANTS, POLES, INTEGRAL MOUNTING BRACKETS, AND FASTENERS SHALL BE PROVIDED AND INSTALLED BY SIGNAGE INSTALLER UNDER A SEPARATE CONTRACT. 3. FOR PLATFORM SIGNAGE MOUNTING HEIGHTS ARE PROVIDED ON BT120-ANP211 TO 215, TYP. SEE ADDITIONAL INFORMATION ON BT120-AEE ELEVATION DRAWING SERIES. 4. NO MOUNTING DETAIL IN CALLOUT INDICATES ADHESION INSTALLATION. SIGNS WITH (*) TO INDICATE MOUNTING BRACKET BY SOUND TRANSIT. 5. COORDINATE WITH EXTERIOR AND INTERIOR ELEVATIONS FOR LOCATION OF WALL-MOUNTED SIGNS. 6. SIGNS AND ACCESSORIES ARE IN SEPARATE SIGNAGE CONTRACT. THEY ARE GRAPHICALLY SHOWN IN HALF TONE. 7. SIGNS REQUIRING BLOCKING OR ATTACHMENT SUPPORTS OR FOOTINGS UNDER THIS CONTRACT ARE IDENTIFIED BY SIGNAGE MOUNTING DETAILS PROVIDED IN THIS CONTRACT. SIGNAGE GRAPHIC LEGEND: SIGNAGE TAG = STA = STA -F2.A -XXX A/BT120-AED9XX SOUND TRANSIT STATION CODE BT120 (SOUTH RENTON TRANSIT CENTER) F2.A =SIGN TYPE . LAYOUT TYPE A/BT120-AED9XX =MOUNTING DETAIL =INDICATION OF PRIMARY SIGN FACE =INDICATION OF SECONDARY SIGN FACE XXX =UNIQUE LOCATION # FACILITY TYPE A7 STATION IDENTIFICATION TYPE B2 / TYPE D2 PLATFORM IDENTIFICATION TYPE C6 CUSTOMER INFORMATION TYPE F3 SIGNATE TYPES (NTS): 7'-11" 3'-0"3'-0" CL CL 1'-0" 4'-0" 2'-0" 3'-10" 3'-10" 2'-0" 3'-9" COLUMN WINDSCREEN FRAME SEE B/ BT120-AED915 FOR MOUNTING DETAIL SEE A/ BT120-AED914 FOR MOUNTING DETAIL SEE A/ BT120-AED914 FOR MOUNTING DETAIL SEE D/ BT120-AED914 FOR MOUNTING DETAIL TYPE C3 CUSTOMER INFORMATION SEE C/ BT120-AED914 FOR MOUNTING DETAIL 2'-0" 3'-10" 3'-9" TYPE B6 CUSTOMER INFORMATION SEE C/ BT120-AED914 FOR MOUNTING DETAIL 1'-2" 28 1/2"28 1/2" 6'-4" 6'-4" 1'-2" CL 10'-2" 9'-0" MIN (D2) 8'-2" MIN, TYP 9'-0" 1'-4" 4'-0" DIRECTIONAL TYPE D14 2'-4" 1'-5" C1 - DUAL SIGNS FACILITY TYPE E1/E6 SEE E/ BT120-AED914 FOR MOUNTING DETAIL TYPE R3 STAINLESS STEEL RAILINGS, GDR-9 REGULATORY EQ EQ 2'-6" MOUNTING DETAIL PROVIDE BY SOUND TRANSIT 10'-0" TYPE F1 8'-0" FACILITY SEE C/ BT120-AED915 FOR MOUNTING DETAIL 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:30 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ANP214 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE PLATFORM SIGNAGE PLAN PLATFORM - SECTOR C JC DH CC JC DH CC 1/8" = 1'-0" 12/10/2024 415ISSUED FOR BID12/10/2024 SCALE IN FEET 4 0 88 16 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 1 1 1 1 06/13/2025 ADDENDUM #1 1 1 1 1 1.E 1.D 1.F 1.15 MA T C H L I N E : SE E D W G BT 1 2 0 -AN P 2 1 4 BUS BAY 5 BUS BAY 4 1.16 1.17 12'-0"3'-6"2'-0" 36'-0"54'-0"CL CL BT120-F1.K-509 C/BT120-AED915 BT120-B6-109 C/BT120-AED914 BT120-E1-404 E/BT120-AED914 BT120-E6-415 E/BT120-AED914 BT120-E6-416 E/BT120-AED914 BT120-E1-405 E/BT120-AED914 BT120-B6-108 C/BT120-AED914 BT120-D14-309 C/BT120-AED914 BT120-D14-308 C/BT120-AED914 CES LIGHT POLE, TYP. CL CL CL CL CL NOTES: 1. SEE CIVIL DRAWINGS BT120-CMP100 TO BT120-CMP205 FOR SITE SIGNAGE, AND TYPE R SIGNS THAT ARE OUTSIDE OF BUS PLATFORM AREA. 2. BUILDING INFORMATION SIGNAGE IS INCLUDED IN THIS CONTRACT. FOR BUILDING INFORMATION SIGNAGE REFER TO SPECIFICATION SECTION 10 14 13 -BUILDING INFORMATION SIGNAGE. ALL OTHER SIGNAGE, INCLUDING SIGNAGE PANELS, PENDANTS, POLES, INTEGRAL MOUNTING BRACKETS, AND FASTENERS SHALL BE PROVIDED AND INSTALLED BY SIGNAGE INSTALLER UNDER A SEPARATE CONTRACT. 3. FOR PLATFORM SIGNAGE MOUNTING HEIGHTS ARE PROVIDED ON BT120-ANP211 TO 215, TYP. SEE ADDITIONAL INFORMATION ON BT120-AEE ELEVATION DRAWING SERIES. 4. NO MOUNTING DETAIL IN CALLOUT INDICATES ADHESION INSTALLATION. SIGNS WITH (*) TO INDICATE MOUNTING BRACKET BY SOUND TRANSIT. 5. COORDINATE WITH EXTERIOR AND INTERIOR ELEVATIONS FOR LOCATION OF WALL-MOUNTED SIGNS. 6. SIGNS AND ACCESSORIES ARE IN SEPARATE SIGNAGE CONTRACT. THEY ARE GRAPHICALLY SHOWN IN HALF TONE. 7. SIGNS REQUIRING BLOCKING OR ATTACHMENT SUPPORTS OR FOOTINGS UNDER THIS CONTRACT ARE IDENTIFIED BY SIGNAGE MOUNTING DETAILS PROVIDED IN THIS CONTRACT. SIGNAGE GRAPHIC LEGEND: SIGNAGE TAG = STA = STA -F2.A -XXX A/BT120-AED9XX SOUND TRANSIT STATION CODE BT120 (SOUTH RENTON TRANSIT CENTER) F2.A =SIGN TYPE . LAYOUT TYPE A/BT120-AED9XX =MOUNTING DETAIL =INDICATION OF PRIMARY SIGN FACE =INDICATION OF SECONDARY SIGN FACE XXX =UNIQUE LOCATION # FACILITY TYPE A7 STATION IDENTIFICATION TYPE B2 / TYPE D2 PLATFORM IDENTIFICATION TYPE C6 CUSTOMER INFORMATION TYPE F3 SIGNATE TYPES (NTS): 7'-11" 3'-0"3'-0" CL CL 1'-0" 4'-0" 2'-0" 3'-10" 3'-10" 2'-0" 3'-9" COLUMN WINDSCREEN FRAME SEE B/ BT120-AED915 FOR MOUNTING DETAIL SEE A/ BT120-AED914 FOR MOUNTING DETAIL SEE A/ BT120-AED914 FOR MOUNTING DETAIL SEE D/ BT120-AED914 FOR MOUNTING DETAIL TYPE C3 CUSTOMER INFORMATION SEE C/ BT120-AED914 FOR MOUNTING DETAIL 2'-0" 3'-10" 3'-9" TYPE B6 CUSTOMER INFORMATION SEE C/ BT120-AED914 FOR MOUNTING DETAIL 1'-2" 28 1/2"28 1/2" 6'-4" 6'-4" 1'-2" CL 10'-2" 9'-0" MIN (D2) 8'-2" MIN, TYP 9'-0" 1'-4" 4'-0" DIRECTIONAL TYPE D14 2'-4" 1'-5" C1 - DUAL SIGNS FACILITY TYPE E1/E6 SEE E/ BT120-AED914 FOR MOUNTING DETAIL TYPE R3 STAINLESS STEEL RAILINGS, GDR-9 REGULATORY EQ EQ 2'-6" MOUNTING DETAIL PROVIDE BY SOUND TRANSIT 10'-0" TYPE F1 8'-0" FACILITY SEE C/ BT120-AED915 FOR MOUNTING DETAIL 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:31 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ANP215 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE PLATFORM SIGNAGE PLAN PLATFORM - SECTOR D JC DH CC JC DH CC 1/8" = 1'-0" 12/10/2024 416ISSUED FOR BID12/10/2024 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE IN FEET 4 0 88 16 1 1 1 06/13/2025 ADDENDUM #1 1 1 1 1 1 1 1.A1.B1.C A BT120-AEX712 BUS BAY FLAG POLE WINDSCREEN DOWSPOUT, C-1, TYP. GUTTER, C-1, TYP. PLATFORM 3' - 9 " V.I.F. 9'-4" V.I.F. 13'-11 1/2" V.I.F. 10'-7" 21'-4" LAMINATED SAFETY GLASS FOR ART WORK, APA-1 PLASTIC GLAZING, PP-1 9" PLATFORM HORIZONTAL LIFE LINE FALL RESTRAINT SYSTEM, TYP. FACE OF CLERESTORY NO ART GLASS PANEL BEYOND END COLUMN, TYP. NOTE: FOR SIGNAGE LOCATIONS, SEE SIGNAGE SHEETS V.I.F. 11'-9 1/2" V.I.F. 15'-2 1/2" 1 / 48 SLOPE 1/2" / 12" 3'-6"3'-6" STEEL COLUMN, C-1, TYP. METAL COLUMN COVER, C-1, TYP. J BT120-AED900 FASCIA, C-2, TYP. 14' - 0"14' - 0" A BT120-AED916 A BT120-AED916 SMART CARD READER PUSH BUTTON AUDIO 3/4" / 12" C-1: RAILWAY GRAY, CMYK 0/0/0/80 C-2: LAND GRAY, CMYK 0/0/0/6 C-3: WAVE TEAL, CMYK 92/23/22/32 C-4: KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U 1. ALL BENCHES ON PLATFORM ARE BENCH-1 TYPE, TYP, UNO. 2. ALL LEAN RAILS ARE LR-1, TYP. 3. ART GLASS UNIT, APA-1 SHALL BE PROVIDED BY OTHERS AT CLERESTORIES AND UPPER PORTION OF WINDSCREEN. CONTRACTOR TO COORDINATE WITH SUPPLIER TO ASSEMBLY UNIT TO ALUMINUM STOREFRONT SYSTEM SF-1 FOR INSTALLATION. 4. ACCENT STRIPS ON COLUMN CLADDINGS ARE PAINTED C-3, TYP, UNO. 5. ACCENT STRIP ON COLUMN CLADDING AT BAY 2 AND BAY 7 TO BE PAINTED C-4. 6. LOCATE DRAIN CLEANOUT AT COLUMN SIDE CLEAR FROM WINDSCREEN, TVM, OR ANY OBJECTS ON THE PLATFORM FOR ACCESS. EXTERIOR COLOR NOTES: GENERAL NOTES: 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/5/2025 2:21:45 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEE811 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR ELEVATIONS PLATFORM - END JC DH CC JC DH CC 1/2" = 1'-0" 12/10/2024 417ISSUED FOR BID12/10/2024 SCALE IN FEET 1 02 2 4 SCALE: 1/2" = 1'-0" WEST ELEVATION FACING RAINIER AVENUE S. - SECTOR D A 1 06/13/2025 ADDENDUM #1 1 1 1 1.11.21.31.4 A BT120-AEX711 24'-0"24'-0"24'-0" BENCH-1, TYP. DIGITAL SIGN -STRIDECLOSED CIRCUIT TELEVISION CAMERA, TYP. METAL FASCIA, C-2, TYP. METAL SOFFIT PANEL, TYP. METAL FASCIA, C-2, TYP. TOP OF BUS BAY PLATFORM, TYP. A BT120-APD101 RECESS LIGHT FIXTURE, TYP. ACCESS HATCH, TYP. LIGHT FIXTURE, TYP. TICKET VENDING MACHINE WINDSCREEN STRIDE PYLON 8'-3" 3'-10" V.I.F. 9'-3" PUSH BUTTON AUDIO SMART CARD READER CLERESTORY FOR ART GLASS INSTALLATION APA-1, ALUMINUM STOREFRONT FRAME, SF-1, TYP. CONTINUOUS CANOPY FASICA, C-2, TYP. METAL COLUMN COVER, C-1, TYP CL STEEL CLADDING, C-2, TYP. SMART CARD READER D BT120-AID908 5'-10"ST SIGNAGE, TYP. CL TYP 5'-10"5'-10" CLPLASTIC GLAZING, PP-1, TYP. BENCH-2 TRASH/ RECYCLING RECEPTACLES TYP 2'-8" LR-1, TYP CL 1.1 1.2 1.3 1.4 A BT120-AEX711 24'-0"24'-0"24'-0" WINDSCREEN STRIDE PYLON LINEAR LIGHT FIXTURES AT CANOPY METAL SOFFIT, TYP. TRANSIT CENTER CANOPY STEEL COLUMN, TYP. STRUCTURAL STEEL ROD, TYP. CANOPY FASCIA, C-2, TYP. TRASH/RECYCLING RECEPTACLES, TYP. RECESS LIGHT FIXTURE, TYP. METAL ROOFING METAL SOFFIT PANEL TOP OF BUS BAY PLATFORM, TYP. ACCESS PANEL, TYP. TICKET VENDING MACHINE HORIZONTAL LIFE LINE FALL RESTRAINT SYSTEM, TYP. 8'-3" 3'-10" V.I.F. 10'-4" D BT120-AED900 CL ST SIGNAGE, TYP.6'-0"5'-10"CL 5'-10" CL LR-1, TYP. LAMINATED SAFETY GLASS FOR ART WORK, APA-1, TYP C-1: RAILWAY GRAY, CMYK 0/0/0/80 C-2: LAND GRAY, CMYK 0/0/0/6 C-3: WAVE TEAL, CMYK 92/23/22/32 C-4: KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U 1. ALL BENCHES ON PLATFORM ARE BENCH-1 TYPE, TYP, UNO. 2. ALL LEAN RAILS ARE LR-1, TYP. 3. ART GLASS UNIT, APA-1 SHALL BE PROVIDED BY OTHERS AT CLERESTORIES AND UPPER PORTION OF WINDSCREEN. CONTRACTOR TO COORDINATE WITH SUPPLIER TO ASSEMBLY UNIT TO ALUMINUM STOREFRONT SYSTEM SF-1 FOR INSTALLATION. 4. ACCENT STRIPS ON COLUMN CLADDINGS ARE PAINTED C-3, TYP, UNO. 5. ACCENT STRIP ON COLUMN CLADDING AT BAY 2 AND BAY 7 TO BE PAINTED C-4. 6. LOCATE DRAIN CLEANOUT AT COLUMN SIDE CLEAR FROM WINDSCREEN, TVM, OR ANY OBJECTS ON THE PLATFORM FOR ACCESS. EXTERIOR COLOR NOTES: GENERAL NOTES: 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 1/20/2025 11:01:14 AM 1/4" = 1'-0" BT120 0 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEE812 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR ELEVATIONS PLATFORM - BUS BAY 1 12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1/4" = 1'-0" BT120-APP212 NORTH ELEVATION AT CANOPY - BUS BAY 1 A SCALE: 1/4" = 1'-0" BT120-APP212 SOUTH ELEVATION AT CANOPY - BUS BAY B SCALE IN FEET 2 44 80 4 84 8 RTA/CN 0205-24 1.51.61.7 24'-0"24'-0" STRIDE PYLON, TYP. KCM RTIS SMART CARD READER, TYP. BENCH-2, TYP.ELECTRICAL CABINET TRASH RECEPTACLE, TYP. ART INSTALLATION APA-1 AT ALUMINUM STOREFRONT FRAME, SF-1, TYP CLOSED CIRCUIT TELEVISION CAMERA, TYP. CLOSED CIRCUIT TELEVISION CAMERA, TYP. METAL SOFFIT PANEL, TYP. METAL FASCIA, C-2, TYP. METAL ROOFING BUS FLAG AT FOREGROUND LIGHT FIXTURE, TYP. CLERESTORIES, TYP. SMART CARD READER TYP. 7'-0" A.F.F. KCM RTIS LIGHT FIXTURE, TYP. SIGNAGE, SEE SIGNAGE PLAN ST SIGNAGE, TYP. V.I.F. 9'-6" 3'-10" 8'-3" ACCESS HATCH, TYP. 8'-3" 3'-10" V.I.F. 10'-3" CLCL J BT120-AED900 5'-10"4'-6" TYP 2'-8" LR-1 @ FOREGROUND CL 1.5 1.6 1.7 V.I.F. 9'-6" 3'-10" 8'-3" 8'-3" 3'-10" V.I.F. 10'-3" SMART CARD READER, TYP. LR-1 ELECTRICAL CABINETTRASH RECEPTACLE, TYP. ART INSTALLATION, APA-1, TYP CLOSED CIRCUIT TELEVISION CAMERA, TYP. METAL SOFFIT PANEL, TYP. METAL FASCIA, C-2, TYP. METAL ROOFING BUS FLAG AT FOREGROUND LIGHT FIXTURE, TYP. CLERESTORIES, TYP. PUSH BUTTON AUDIO STRIDE DIGITAL SIGNS LIGHT FIXTURE, TYP. ST SIGNAGE, TYP. ACCESS HATCH, TYP. TVM STRIDE PYLON CL CL CL PLASTIC GLAZING, TYP. 5'-10"4'-6" BENCH -2 C-1: RAILWAY GRAY, CMYK 0/0/0/80 C-2: LAND GRAY, CMYK 0/0/0/6 C-3: WAVE TEAL, CMYK 92/23/22/32 C-4: KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U 1. ALL BENCHES ON PLATFORM ARE BENCH-1 TYPE, TYP, UNO. 2. ALL LEAN RAILS ARE LR-1, TYP. 3. ART GLASS UNIT, APA-1 SHALL BE PROVIDED BY OTHERS AT CLERESTORIES AND UPPER PORTION OF WINDSCREEN. CONTRACTOR TO COORDINATE WITH SUPPLIER TO ASSEMBLY UNIT TO ALUMINUM STOREFRONT SYSTEM SF-1 FOR INSTALLATION. 4. ACCENT STRIPS ON COLUMN CLADDINGS ARE PAINTED C-3, TYP, UNO. 5. ACCENT STRIP ON COLUMN CLADDING AT BAY 2 AND BAY 7 TO BE PAINTED C-4. 6. LOCATE DRAIN CLEANOUT AT COLUMN SIDE CLEAR FROM WINDSCREEN, TVM, OR ANY OBJECTS ON THE PLATFORM FOR ACCESS. EXTERIOR COLOR NOTES: GENERAL NOTES: 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:34 PM 1/4" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEE813 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR ELEVATIONS PLATFORM - BUS BAY 2 AND 8 JC DH CC JC DH CC 12/10/2024 419ISSUED FOR BID12/10/2024 SCALE: 1/4" = 1'-0" BT120-APP213 NORTH ELEVATION CANOPY - BUS BAY 2 A SCALE IN FEET 2 44 80 SCALE: 1/4" = 1'-0" BT120-APP213 SOUTH ELEVATION CANOPY - BUS BAY 8 B 1 1 1 06/13/2025 ADDENDUM #1 11 1.121.131.141.15 24'-0"24'-0"24'-0"6'-0" TYP. TRANSIT CENTER CANOPY STEEL COLUMN, TYP. STRUCTURAL STEEL ROD, TYP. CANOPY FASCIA, C-2, TYP. TRASH RECEPTACLE, TYP. ART INSTALLATION, APA-1, TYP BUS FLAG AT FOREGROUND PUSH BUTTON AUDIO LIGHT FIXTURE, TYP. CLOSED CIRCUIT TELEVISION CAMERA, TYP. BUS FLAG AT BACKGROUND BENCH-2, TYP. TOP OF BUS BAY PLATFORM, TYP. WINDSCREEN, TYP. ST SIGNAGE, TYP. 8'-3" 3'-10" V.I.F. 9'-11" KCM RTIS LEAN RAIL, LR-1, TYP. B BT120-AED901 CONTINUOUS STEEL FASCIA, C-2 STEEL CLADDING, C-2, TYP. METAL COLUMN COVER, C-1, TYP. STEEL COLUMN, C-1, TYP. ALUMINUM FRAMED STOREFRONTS, SF-1, TYP. CL 1 BT120-AED904 SIM 5'-10"5'-10" CL 1 1.81.91.101.111.12 6'-0" TYP24'-0"24'-0"24'-0"24'-0" TOP OF BUS BAY PLATFORM, TYP. KCM RTIS V.I.F. 11'-5" 3'-10" 8'-3" 6'-0"2'-0"6'-0"2'-0" CL CL ST SIGNAGE, TYP. ACCESS HATCH, TYP. 4'-10" 5'-10" 5'-10"13'-1" BENCH-1 CL LEAN RAIL, LR-1, TYP TYP 2'-8" CL CL C-1: RAILWAY GRAY, CMYK 0/0/0/80 C-2: LAND GRAY, CMYK 0/0/0/6 C-3: WAVE TEAL, CMYK 92/23/22/32 C-4: KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U 1. ALL BENCHES ON PLATFORM ARE BENCH-1 TYPE, TYP, UNO. 2. ALL LEAN RAILS ARE LR-1, TYP. 3. ART GLASS UNIT, APA-1 SHALL BE PROVIDED BY OTHERS AT CLERESTORIES AND UPPER PORTION OF WINDSCREEN. CONTRACTOR TO COORDINATE WITH SUPPLIER TO ASSEMBLY UNIT TO ALUMINUM STOREFRONT SYSTEM SF-1 FOR INSTALLATION. 4. ACCENT STRIPS ON COLUMN CLADDINGS ARE PAINTED C-3, TYP, UNO. 5. ACCENT STRIP ON COLUMN CLADDING AT BAY 2 AND BAY 7 TO BE PAINTED C-4. 6. LOCATE DRAIN CLEANOUT AT COLUMN SIDE CLEAR FROM WINDSCREEN, TVM, OR ANY OBJECTS ON THE PLATFORM FOR ACCESS. EXTERIOR COLOR NOTES: GENERAL NOTES: 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:35 PM 1/4" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEE814 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR ELEVATIONS PLATFORM - BUS BAY 3 JC DH CC JC DH CC 12/10/2024 420ISSUED FOR BID12/10/2024 SCALE: 1/4" = 1'-0" BT120-APP214 NORTH ELEVATION - BUS BAY 3 - WEST A SCALE: 1/4" = 1'-0" BT120-APP214 NORTH ELEVATION - BUS BAY 3 - EAST B SCALE IN FEET 2 44 80 NOTE: SEE DWG BT120-AEE811 & BT120-AEE812 FOR SIMILAR INFORMATION 1 11 1 06/13/2025 ADDENDUM #1 11 1.11 1.12 1.13 1.14 1.15 24'-0"24'-0"24'-0"24'-0"6'-0" BUS FLAG, TYP. CLOSED CIRCUIT TELEVISION CAMERA, TYP. PUSH BUTTON AUDIO TOP OF BUS BAY PLATFORM, TYP. ST SIGNAGE, TYP. KCM RTIS 8'-3" 3'-10" 9'-11" CONTINUOUS STEEL FASCIA, C-2, TYP. STEEL COLUMN, C-1, TYP. CLCL METAL COLUMN COVER, C-1, TYP. 6'-0"2'-0" 5'-10" CL ACCESS HATCH, TYP. BENCH-2 5'-10"5'-10"13'-1" 1 1.8 1.9 1.10 1.11 TYP. 6'-0"24'-0"24'-0"24'-0" ELECTRICAL CABINET PUSH BUTTON AUDIO BUS FLAG BENCH-2, TYP. TRANSIT CENTER CANOPY STEEL COLUMN, TYP. STRUCTURAL STEEL ROD, TYP. CANOPY FASCIA, C-2, TYP. LINEAR LT. FIXTURES, TYP. WINDSCREEN, TYP. KCM RTIS CLOSED CIRCUIT TELEVISION CAMERA, TYP. ART INSTALLATION, APA-1 TOP OF BUS BAY PLATFORM, TYP. ST SIGNAGE, TYP. HORIZONTAL LIFE LINE FALL RESTRAIN SYSTEM, TYP. 11'-4" 3'-10" 8'-3" F BT120-AED900 H BT120-AED900 ST SIGNAGE, TYP. CONTINUOUS STEEL FASCIA, C-2, TYP. CL CL H BT120-AED900 LR-1, TYP.LR-1, TYP. 6'-0"2'-0" 5'-10" 4'-10" A BT120-AID908 ART GLASS APA-1 INSTALLATION AT WITH ALUMINUM STOREFRONT FRAME SF-1, TYP. TYP 2'-8" CL C-1: RAILWAY GRAY, CMYK 0/0/0/80 C-2: LAND GRAY, CMYK 0/0/0/6 C-3: WAVE TEAL, CMYK 92/23/22/32 C-4: KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U 1. ALL BENCHES ON PLATFORM ARE BENCH-1 TYPE, TYP, UNO. 2. ALL LEAN RAILS ARE LR-1, TYP. 3. ART GLASS UNIT, APA-1 SHALL BE PROVIDED BY OTHERS AT CLERESTORIES AND UPPER PORTION OF WINDSCREEN. CONTRACTOR TO COORDINATE WITH SUPPLIER TO ASSEMBLY UNIT TO ALUMINUM STOREFRONT SYSTEM SF-1 FOR INSTALLATION. 4. ACCENT STRIPS ON COLUMN CLADDINGS ARE PAINTED C-3, TYP, UNO. 5. ACCENT STRIP ON COLUMN CLADDING AT BAY 2 AND BAY 7 TO BE PAINTED C-4. 6. LOCATE DRAIN CLEANOUT AT COLUMN SIDE CLEAR FROM WINDSCREEN, TVM, OR ANY OBJECTS ON THE PLATFORM FOR ACCESS. EXTERIOR COLOR NOTES: GENERAL NOTES: 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:37 PM 1/4" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEE815 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR ELEVATIONS PLATFORM - BUS BAY 6 AND 7 JC DH CC JC DH CC 12/10/2024 421ISSUED FOR BID12/10/2024 SCALE: 1/4" = 1'-0" BT120-APP214 SOUTH ELEVATION - BUS BAY 6 B SCALE: 1/4" = 1'-0" BT120-APP214 SOUTH ELEVATION - BUS BAY 7 A SCALE IN FEET 2 44 80 NOTE: SEE DWG BT120-AEE811 & BT120-AEE812 FOR SIMILAR INFORMATION 1 06/13/2025 ADDENDUM #1 1 1 1 1.E STEEL MEMBERS OF SHELTER TO BE PAINTED, C-2, TYP. PLASTIC GLAZING, PP-1, TYP. ROOF PANEL, PP-2, TYP. 1.161.17 BENCH-2 PAINTED STEEL, C-2, TYP. PLASTIC GLAZING, PP-1, TYP. E BT120-AEX714 C BT120-AEX714 D BT120-AEX714 D BT120-AEX714 OPP. LR-1 1.16 1.17 C-2, TYP. E BT120-AEX714 C-2, TYP. C-1: RAILWAY GRAY, CMYK 0/0/0/80 C-2: LAND GRAY, CMYK 0/0/0/6 C-3: WAVE TEAL, CMYK 92/23/22/32 C-4: KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U 1. ALL BENCHES ON PLATFORM ARE BENCH-1 TYPE, TYP, UNO. 2. ALL LEAN RAILS ARE LR-1, TYP. 3. ART GLASS UNIT, APA-1 SHALL BE PROVIDED BY OTHERS AT CLERESTORIES AND UPPER PORTION OF WINDSCREEN. CONTRACTOR TO COORDINATE WITH SUPPLIER TO ASSEMBLY UNIT TO ALUMINUM STOREFRONT SYSTEM SF-1 FOR INSTALLATION. 4. ACCENT STRIPS ON COLUMN CLADDINGS ARE PAINTED C-3, TYP, UNO. 5. ACCENT STRIP ON COLUMN CLADDING AT BAY 2 AND BAY 7 TO BE PAINTED C-4. 6. LOCATE DRAIN CLEANOUT AT COLUMN SIDE CLEAR FROM WINDSCREEN, TVM, OR ANY OBJECTS ON THE PLATFORM FOR ACCESS. EXTERIOR COLOR NOTES: GENERAL NOTES: PARATRANSIT SHELTER HAS SIMILAR ELEVATIONS ELEVATIONS NOTE: 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 1/20/2025 11:01:21 AM BT120 0 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEE816 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR ELEVATIONS PLATFORM - BUS BAY 4 12/10/2024 J.C. D.H. C.C. 1/2" = 1'-0 ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE IN FEET 2 44 80 SCALE: 1/2" = 1'-0" BT120-APP213 EAST ELEVATION - KCM SHELTER / PARATRANSIT SHELTER B SCALE: 1/2" = 1'-0" BT120-APP213 NORTH ELEVATION - KCM SHELTER / PARATRANSIT SHELTER A SCALE: 1/2" = 1'-0" BT120-APP213 SOUTH ELEVATION - KCM SHELTER / PARATRANSIT SHELTER C 4 4 RTA/CN 0205-24 1.A1.B1.C A BT120-AEX712 14'-0"14'-0" TRANSIT CENTER CANOPY STEEL COLUMN, C-1, TYP. CANOPY FASCIA, C-2, TYP. METAL ROOFING METAL SOFFIT PANEL, TYP. GUTTER, C-1, TYP. ST SIGNAGE TOP OF BUS BAY PLATFORM., TYP. A BT120-AED900 A BT120-AED900 B BT120-AED900 E BT120-AED900 3' - 9 " 10 ' - 3 " V. I . F . 14 ' - 1 0 " V. I . F . 11 ' - 6 " TRASH/ RECYCLING RECEPTACLES, TYP. RAILING, GDR-9 SMART CARD READER HORIZONTAL LIFELINE FALL RESTRAINT SYSTEM, TYP. PLATFORMPLATFORM 3' - 6"3' - 6" 1 BT120-AED904 V. I . F . 16 ' - 1 " V. I . F . 12 ' - 8 1 / 2 " A BT120-AID906 ST SIGNAGE OPP 5'-6"CLCLCL 3/4" / 12" 1/2" / 12" C-1: RAILWAY GRAY, CMYK 0/0/0/80 C-2: LAND GRAY, CMYK 0/0/0/6 C-3: WAVE TEAL, CMYK 92/23/22/32 C-4: KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U 1. ALL BENCHES ON PLATFORM ARE BENCH-1 TYPE, TYP, UNO. 2. ALL LEAN RAILS ARE LR-1, TYP. 3. ART GLASS UNIT, APA-1 SHALL BE PROVIDED BY OTHERS AT CLERESTORIES AND UPPER PORTION OF WINDSCREEN. CONTRACTOR TO COORDINATE WITH SUPPLIER TO ASSEMBLY UNIT TO ALUMINUM STOREFRONT SYSTEM SF-1 FOR INSTALLATION. 4. ACCENT STRIPS ON COLUMN CLADDINGS ARE PAINTED C-3, TYP, UNO. 5. ACCENT STRIP ON COLUMN CLADDING AT BAY 2 AND BAY 7 TO BE PAINTED C-4. 6. LOCATE DRAIN CLEANOUT AT COLUMN SIDE CLEAR FROM WINDSCREEN, TVM, OR ANY OBJECTS ON THE PLATFORM FOR ACCESS. EXTERIOR COLOR NOTES: GENERAL NOTES: 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - A - v 2 0 2 0 . r v t 6/ 5 / 2 0 2 5 2 : 0 0 : 3 0 P M BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEX711 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE CROSS SECTIONS PLATFORMJCDH CC JC DH CC 12/10/2024 423ISSUED FOR BID12/10/2024 NOTE: SEE SHEET BT120-AEE811 & BT120-AEE812 FOR SIMILAR INFORMATION SCALE IN FEET 1 02 2 4SCALE: 1/2" = 1'-0"BT120-ACP212 TRANSVERSE SECTION AT CANOPY COLUMN A 1 06/13/2025 ADDENDUM #1 1 1 1 1 1 1.1 1.2 1.3 1.4 A BT120-AEX711 V.I.F 9'-5" MIN. TRASH/ RECYCLING RECEPTACLES, TYP. ST SIGN, SEE SIGNAGE PLAN, TYP. WINDSCREEN, TYP.TICKET VENDING MACHINE STRIDE PYLON LIGHT FIXTURE, TYP. 1 BT120-AED912 H BT120-AED900 G BT120-AED900 C BT120-AED900 STEEL COLUMN, C-1, TYP ALUMINUM-FRAMED STOREFRONT, SF-1, TYP METAL COLUMN COVER, C-1, TYP HORIZONTAL LIFELINE FALL RESTRAINT SYSTEM C-1: RAILWAY GRAY, CMYK 0/0/0/80 C-2: LAND GRAY, CMYK 0/0/0/6 C-3: WAVE TEAL, CMYK 92/23/22/32 C-4: KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U 1. ALL BENCHES ON PLATFORM ARE BENCH-1 TYPE, TYP, UNO. 2. ALL LEAN RAILS ARE LR-1, TYP. 3. ART GLASS UNIT, APA-1 SHALL BE PROVIDED BY OTHERS AT CLERESTORIES AND UPPER PORTION OF WINDSCREEN. CONTRACTOR TO COORDINATE WITH SUPPLIER TO ASSEMBLY UNIT TO ALUMINUM STOREFRONT SYSTEM SF-1 FOR INSTALLATION. 4. ACCENT STRIPS ON COLUMN CLADDINGS ARE PAINTED C-3, TYP, UNO. 5. ACCENT STRIP ON COLUMN CLADDING AT BAY 2 AND BAY 7 TO BE PAINTED C-4. 6. LOCATE DRAIN CLEANOUT AT COLUMN SIDE CLEAR FROM WINDSCREEN, TVM, OR ANY OBJECTS ON THE PLATFORM FOR ACCESS. EXTERIOR COLOR NOTES: GENERAL NOTES: 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 1/20/2025 11:01:23 AM 1/4" = 1'-0" BT120 0 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEX712 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE LONGITUDINAL SECTIONS PLATFORM12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1/4" = 1'-0"BT120-APP212 TYPICAL LONGITUDINAL SECTION AT CANOPY A SCALE IN FEET 2 44 80 4 4 RTA/CN 0205-24 1.2 METAL COLUMN COVER, C-1, TYP. DOWNSPOUT GUTTERS A BT120-AED904 OVERFLOW 1.B METAL COLUMN COVER, C-1, TYP. DOWNSPOUT B BT120-AED904 OVERFLOW C-1: RAILWAY GRAY, CMYK 0/0/0/80 C-2: LAND GRAY, CMYK 0/0/0/6 C-3: WAVE TEAL, CMYK 92/23/22/32 C-4: KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U 1. ALL BENCHES ON PLATFORM ARE BENCH-1 TYPE, TYP, UNO. 2. ALL LEAN RAILS ARE LR-1, TYP. 3. ART GLASS UNIT, APA-1 SHALL BE PROVIDED BY OTHERS AT CLERESTORIES AND UPPER PORTION OF WINDSCREEN. CONTRACTOR TO COORDINATE WITH SUPPLIER TO ASSEMBLY UNIT TO ALUMINUM STOREFRONT SYSTEM SF-1 FOR INSTALLATION. 4. ACCENT STRIPS ON COLUMN CLADDINGS ARE PAINTED C-3, TYP, UNO. 5. ACCENT STRIP ON COLUMN CLADDING AT BAY 2 AND BAY 7 TO BE PAINTED C-4. 6. LOCATE DRAIN CLEANOUT AT COLUMN SIDE CLEAR FROM WINDSCREEN, TVM, OR ANY OBJECTS ON THE PLATFORM FOR ACCESS. EXTERIOR COLOR NOTES: GENERAL NOTES: 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:30:42 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEX713 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE SECTIONS PLATFORM12/10/2024 J.C. D.H. C.C. 1/2" = 1'-0" ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1/2" = 1'-0" BT120-AED903 SECTION @ CABLE RACEWAY I A SCALE: 1/2" = 1'-0" BT120-AED903 SECTION @ CABLE RACEWAY II B SCALE IN FEET 1 02 2 4 4 RTA/CN 0205-24 PAINTED STEEL OUTSIDE BEAM, C-2 - (2) SST, SELF-TAPING SCREWS #10-24, 12" OC CONT ISOLATION MATERIAL CONT EXTRUDED ALUM MULLION BAR AND CAP ACRYLIC ROOF PANEL, PP-2, TYP. EA SIDE AS INDICATED SST CAP SCREW BY MULLION MFR T SHAPE STRUCTURAL SUPPORT BEAM PAINTED STEEL OUTSIDE BEAM, C-2 CONT EXTRUDED ALUM MULLION BAR AND CAP W/ END CAP FILLER, CENTER ON HSS AS INDICATED ACRYLIC ROOF PANEL, PP-2 SST CAP SCREW BY MULLION MFR - 1.E - A - B ROOF PANEL, PP-2, TYP. C-2 LR-1 1/2" / 12" D BT120-AEX714 CONT EXTRUDED ALUM MULLION BAR AND CAP ACRYLIC ROOF PANEL, PP-2, TYP. EA SIDE AS INDICATED STRUCTURAL BEAM METAL CLIP METAL FLASING STEEL FASCIA, C-2, TYP. SEE C/ BT120-AEX714 FOR ACRYLIC ROOF PANEL SUPPORT D BT120-AEX714 CONT EXTRUDED ALUM MULLION BAR AND CAP ACRYLIC ROOF PANEL, PP-2, TYP. EA SIDE AS INDICATED STRUCTURAL BEAM METAL CLIP STEEL FASCIA, C-2, TYP. 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:38 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEX714 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE SHELTER SECTION & DETAILS PLATFORMJC DH CC JC DH CC 12/10/2024 426ISSUED FOR BID12/10/2024 SCALE: 3" = 1'-0"BT120-AEE816 ROOF CONNECTION @ MIDDLE BEAM C SCALE: 3" = 1'-0"BT120-AEE816 ROOM CONNECTION @ END BEAM D SCALE: 1/2" = 1'-0"BT120-AEE816 SECTION AT SHELTER E SCALE: 3" = 1'-0" SHELTER FASCIA AT LOWER ROOF A -SCALE: 3" = 1'-0" SHELTER FASCIA AT HIGHER ROOF B - 1 06/13/2025 ADDENDUM #1 1 1 1 STANDING SEAM METAL ROOFING 20 GA. - 1.5" METAL DECK 3" DIA. DOWNSPOUT BEYOND STRUCTURAL BEAM STEEL CLADDING, C-2, TYP. SEE STOREFRONT SCHEDULE STRUCTURAL COLUMN BEYOND GUTTER, C-1, TYP. 5"6" ROOF SHEATHING STRUCTURAL COLUMN 2X WOOD FRAME STANDING SEAM METAL ROOFING GUTTER, C-1, TYP. 3" DIA. DOWNSPOUT BEYOND SEE STRUCT. METAL FLASHING METAL SOFFIT PANEL 4" 20 GA. - 1.5" METAL DECK ROOF SHEATHING STEEL CLADDING, C-2 METAL FLASHING STANDING SEAM ROOFING METAL STRUCTURAL DECK STRUCTURAL BEAM & METAL BRACKET SOFFIT PANEL ROOF SHEATHING METAL CLIP, TYP. STRUCTURAL COLUMN BEYOND 3" DIA. DOWNSPOUT 3" DIA. OVER FLOW DOWNSPOUT 2" 3" DIA. UPPER DOWNSPOUT UPPER GUTTER LOWER GUTTER DOWNSPOUT DAYLIGHT BELOW METAL SOFFIT OUTRIGGER, SEE STRUCTURAL DWG STRUCTURAL ROD AND CONNECTING PLATE, SEE STRUCTURAL DRAWING STEEL FASCIA, C-2, TYP. STANDING SEAM ROOFING 20 GA. - 1.5" METAL DECK STRUCTURAL MEMBER SOFFIT PANEL METAL GIRT ROOF SHEATHING - TO EDGE OF FASCIA 1'-0" STANDING SEAM METAL ROOFING 20 GA. - 1.5" METAL DECK GUTTER, C-1, TYP. 3" DIA. DOWNSPOUT BEYOND SEE STRUCT. METAL FLASHING METAL SOFFIT PANEL 8" 4" STEEL CLADDING, C-2 3" DIA. DOWNSPOUT INSIDE CONDUITE RACEWAY 5" DIA. CLEANOUT COVER CUT HOLE IN COLUMN COVER FOR 4" DIA. CLEANOUT CONCRETE PLATFORM 3" DIA. OVERFLOW INSIDE CONDUITE RACEWAY CL METAL COLUMN COVER, C-1, TYP. DAYLIGHTED OVERFLOW DRAIN WITH METAL INSECT SCREEN 8" V.I.F. NOTE: LOCATE DRAIN CLEANOUT AT COLUMN SIDE CLEAR FROM WINDSCREEN, TVM, OR ANY OBJECTS ON THE PLATFORM FOR ACCESS NOTES: 1. ROOF PENETRATIONS SHALL HAVE A MIN. 12" CLEARANCE ON ALL SIDES FROM WALLS, CURBS AND OTHER ROOF PENETRATIONS. 2. PENETRATIONS SHALL BE RIGID, ROUND OR SQUARE TUBE AND EXTEND PERPENDICULAR FROM THE ROOF STRUCTURE. 3. TIE-BACK ANCHORS SHALL BE COMPLETELY WATER TIGHT ABOVE ROOF MEMBRANE FLASHING. 4. REFER TO STRUCTURAL DRAWINGS FOR ATTACHMENT AND LOCATION OF TIE-BACK ANCHORS. FALL PROTECTION ANCHOR SYSTEM, SEE ROOF PLAN FOR LOCATIONS. INSTALL IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. SEAMLESS SPUN ALUMINUM FLASHING RUBBER COLLAR FLASHING ROOFING SYSTEM AS SPECIFIED TIE-BACK ANCHORED TO CONCRETE STRUCTURE PER MANUFACTURER INSTRUCTIONS WEATHER RESISTIVE BARRIER AND AIR BARRIER 1.5" METAL DECK STRUCTURAL COLUMN CUSTOMIZED CRICKET SHEET METAL FLASHING CUSTOMIZED CRICKET OUTLINE UNDER ROOFING EDGES OF STANDING SEAM ROOFING COLUMN METAL CLADDING FASTENER, BY METAL CLADDING MNF. BRAKE METAL TO SUPPORT LIGHT FIXTURE LIGHT FIXTURE FASTENER COLUMN METAL CLADDING LOCKABLE LID FLUSH WITH ADJACENT CONCRETE SURFACE METAL HYDRANT BOX OUTER CASING PIPE CONCRETE GRAVELS 0' - 6 1/2" 0' - 6 1/2" 6 1/2". 2 1/2". 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:30:47 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED900 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE CANOPY DETAILS PLATFORM12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1 1/2" = 1'-0" BT120-AEX711 UPPER GUTTER B SCALE: 1 1/2" = 1'-0" BT120-AEX711 LOWER GUTTER @ WINDOW E SCALE: 3" = 1'-0" BT120-AEX712 CANOPY DETAILS - RAKE CONDITION C SCALE: 1 1/2" = 1'-0" BT120-AEE815 UPPER/ LOWER GUTTER ELEVATION F SCALE: 3" = 1'-0" BT120-AEX711 FASCIA DETAIL A SCALE: 1 1/2" = 1'-0" BT120-AEX712 LOWER GUTTER @ END CANOPY G SCALE: 1 1/2" = 1'-0" BT120-AEE815 DOWNSPOUT CLEANOUT H SCALE: 1 1/2" = 1'-0" BT120-AEE812 LIFE LINE FALL RESTRAINT ANCHOR D SCALE: 1 1/2" = 1'-0" CRICKET DETAIL AROUND COLUMN 1 SCALE: 1 1/2" = 1'-0" BT120-AEE811 LIGHTING FIXTURE MOUNTING DETAIL J SCALE: 3" = 1'-0" GROUND HYDRANT BOX (NON-FREEZE)K 4 RTA/CN 0205-24 1.E 1.13B BT120-AED901 - A LR-1: LEAN RAIL, LR-1, TYP. WINDSCREEN FRAME CANOPY COLUMN EXPANSION JOINT, TYP. - C CL 5'-0" 1'-6" 6' - 0" TYP. 7'-8" BENCH-2, TYP @ ADA WAITING AREA 3'-10" LR-1, C-2, TYP. LAMINATED SAFETY GLASS FOR ART WORK, APA-1 METAL COLUMN COVER, C-1, TYP. 8'-0" 2'-2" PLASTIC GLAZING, PP-1 PAINTED STEEL, C-2, TYP. A.F.F. 7'-0" HIGH POINTLOW POINT 1'-0" WINDSCREEN METAL COLUMN COVER, C-1, TYP. D BT120-AED902 A BT120-AED902 E BT120-AED902 B BT120-AED902 C BT120-AED902 F BT120-AED902 G BT120-AED902 LAMINATED SAFETY GLASS FOR ART WORK, APA-1 PLASTIC GLAZING, PP-1 BENCH-2 AT ADA WAITING AREA 1.E WINDSCREEN LEAN RAIL CANOPY COLUMN LAMINATED SAFETY GLASS FOR ART WORK, APA-1 PLASTIC GLAZING, PP-1 C-1: RAILWAY GRAY, CMYK 0/0/0/80 C-2: LAND GRAY, CMYK 0/0/0/6 C-3: WAVE TEAL, CMYK 92/23/22/32 C-4: KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U 1. ALL BENCHES ON PLATFORM ARE BENCH-1 TYPE, TYP. 2. ALL LEAN RAILS ARE LR-1 TYPE, TYP. 3. ART GLASS INSTALLATION SHALL BE PROVIDED FOR THE UPPER PORTION OF THE WINDSCREEN. GENERAL NOTES: EXTERIOR COLOR NOTES: 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 1/20/2025 11:01:27 AM BT120 0 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED901 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE WINDSCREEN DETAILS PLATFORM12/10/2024 J.C. D.H. C.C. 1/2" = 1'-0" ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1/2" = 1'-0" BT120-APP212 ENLARGED PLAN - WINDSCREEN 1 SCALE: 1/2" = 1'-0" TYP WINDSCREEN ELEVATION - BACK C -SCALE: 1/2" = 1'-0" TYP WINDSCREEN ELEVATION - FRONT B - SCALE: 1/2" = 1'-0" TYP WINDSCREEN ELEVATION - RIGHT A - SCALE IN FEET 1 02 2 4 4 84 8 RTA/CN 0205-24 AL I G N ART GLASS INSTALLATION APA-1, ALUMINUM STOREFRONT FRAME, SF-1, TYP. PAINTED WINDSCREEN FRAME FASTENER AL I G N ART GLASS INSTALLATION APA-1, ALUMINUM STOREFRONT FRAME, SF-1, TYP. PAINTED WINDSCREEN FRAME SST ANGLE FASTENED TO HSS OR STL WELDED TO HSS EPDM GASKET PLASTIC GLAZING, PP-1 THROUGH BOLT WITH REMOVABLE TAMPER- RESISTANT FASTENER FASTENER PAINTED WINDSCREEN FRAME EPDM GASKET PLASTIC GLAZING, PP-1 SST GLASS STOP CHANNEL W/ REMOVABLE TAMPER- RESISTANT FASTENER VARIES (6" MIN AFF) ART GLASS INSTALLATION APA-1, ALUMINUM STOREFRONT FRAME, SF-1, TYP. PAINTED WINDSCREEN POST/ FRAME AL I G N ART GLASS INSTALLATION APA-1, ALUMINUM STOREFRONT FRAME, SF-1, TYP. PAINTED WINDSCREEN POST FASTENER PAINTED WINDSCREEN POST/ FRAME SEE 3/BT120-SGD136 PLASTIC GLAZING, PP-1 CONCRETE PLATFORM ART GLASS INSTALLATION APA-1, ALUMINUM STOREFRONT FRAME, SF-1, TYP. PAINTED WINDSCREEN POST/ FRAME PLASTIC GLAZING, PP-1 1.2 DOUBLE SIDED VMS/RTIS HSS STRUCTURAL MEMBER CANOPY 3'-0" TYP 1'-8" @ BAY 1 CL CL W/ ST & KCM EQUIPMENT REQ VERIFY ATTACHMENT SPACING STL PLATE, PER STRUCTURAL VMS/RTIS SUPPORT, TYP. CONT HSS STRUCTURAL MEMBER H - 1.A VMS/RTIS BY OTHERS, RTIS BRACEKT ENCLOSURE BY OTHERS STL MOUNTING PL @ VMS/RTIS LOCATIONS PER STRUCTURAL A / BT120-SGD113 CANOPY SOFFIT HSS STRUCTURAL MEMBER HSS STRUCTURAL MEMBER 3'-0" TYP 1'-8" @ BAY 1 PROVIDE METAL ESCUTCHEON TRIM, FINISH TO MATCH CANOPY SOFFIT PANEL, TYP. SUPPORT MOUNTING ARM/ HANGING PIPE, TYP. 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 1/20/2025 11:01:28 AM BT120 0 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED902 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE WINDSCREEN DETAILS PLATFORM12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3" = 1'-0" BT120-AED901 WINDSCREEN - TOP_DOC A SCALE: 3" = 1'-0" BT120-AED901 WINDSCREEN - MIDDLE B SCALE: 3" = 1'-0" BT120-AED901 WINDSCREEN - BOTTOM C SCALE: 3" = 1'-0" BT120-AED901 WINDSCREEN - TOP CORNER D SCALE: 3" = 1'-0" BT120-AED901 WINDSCREEN - SIDE E SCALE: 3" = 1'-0" BT120-AED901 WINDSCREEN - BOTTOM CONNECTION F SCALE: 3" = 1'-0" BT120-AED901 WINDSCREEN - MIDDLE CONNECTION G SCALE: 1" = 1'-0" BT120-APD101 RCP @ VMS & RTIS DETAIL J SCALE: 1 1/2" = 1'-0" BT120-AED902 VMS & RTIS DETAIL H 4 94 9 RTA/CN 0205-24 1.B 1.2 A BT120-AEX713 B BT120-AEX713 METAL COLUMN COVER, C-1, TYP. DOWNSPOUT DAYLIGHTED OVERFLOW DRAIN METAL COLUMN COVER, C-1, TYP. ABOVE GUTTER ABOVE OUTRIGGER ABOVE OUTRIGGER 4" 4" CONDUIT, TYP. FASTENER, TYP. UNDER CONCRETE SLAB DRAIN PIPE, TYP. CATCH BASIN, TYP. DRAIN, CONNECT TO DRAIN PIPE, TYP. 1.B 1.2 A BT120-AEX713 METAL COLUMN COVER, C-1, TYP. EDGE OF STRUCTURAL BEAM, OVERFLOW DRAIN HOLE UPPER DOWNSPOUT DOWNSPOUT DRAIN HOLE STRUCTURAL COLUMN EDGE OF GUTTERBELOW OUTRIGGER ABOVE OUTRIGGER FASTENER, TYP. 1.B 1.2 A BT120-AEX713 METAL COLUMN COVER, C-1, TYP. ART INSTALLATION , APA-1 & FRAME UPPER DOWNSPOUT DOWNSPOUT DRAIN HOLE OVERFLOW DRAIN HOLE CANOPY COLUMN BELOW OUTRIGGER ABOVE OUTRIGGER EDGE OF ROOFING EDGE OF BEAM, SEE STRUCTURAL FASTENER, TYP. 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:30:55 PM 3" = 1'-0" BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED903 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE CONDUIT RACEWAY DETAILS PLATFORM12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3" = 1'-0" BT120-APP212 ENLARGED COLUMN - LOWER 1 SCALE: 3" = 1'-0" ENLARGED COLUMN - HIGHER 3 SCALE: 3" = 1'-0" ENLARGED COLUMN - MIDDLE 2 SCALE IN FEET 01/41/2 1/2 4 RTA/CN 0205-24 1.2 B BT120-AEX713 METAL COLUMN COVER, C-1, TYP. DOWNSPOUT GUTTERS DOWNSPOUT SOFFIT 2" CONDUIT OVERFLOW 1" CONDUIT 1.B A BT120-AEX713 METAL COLUMN COVER, C-1, TYP. DOWNSPOUT STRUCT. BEAM SOFFIT SOFFIT GLAZING & FRAME STRUCT. BEAM OVERFLOW GUTTER GUTTER ART INSTALLATION , APA-1 WOOD BLOCKING, TYPICAL OR ACCESS PANEL @ LIGHT FIXTURE SUPPORTING PIPES FOR VMS AND RTIS BY OTHERS 6" SEE STRUCTRUAL DRAWING A/BT120-SGD113 FOR ATTACHMENT TO STRUCTURE 12"L REMOVABLE SHEET METAL PANEL W/ TAMPER PROOFED FASTENER WHERE ATTACHMENT OCCURS, MATCH SOFFIT FINISH GIRTS FOR SOFFIT SUPPORT, TYP METAL SOFFIT, TYP C-1: RAILWAY GRAY, CMYK 0/0/0/80 C-2: LAND GRAY, CMYK 0/0/0/6 C-3: WAVE TEAL, CMYK 92/23/22/32 C-4: KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U 1. ALL BENCHES ON PLATFORM ARE BENCH-1 TYPE, TYP, UNO. 2. ALL LEAN RAILS ARE LR-1, TYP. 3. ART GLASS UNIT, APA-1 SHALL BE PROVIDED BY OTHERS AT CLERESTORIES AND UPPER PORTION OF WINDSCREEN. CONTRACTOR TO COORDINATE WITH SUPPLIER TO ASSEMBLY UNIT TO ALUMINUM STOREFRONT SYSTEM SF-1 FOR INSTALLATION. 4. ACCENT STRIPS ON COLUMN CLADDINGS ARE PAINTED C-3, TYP, UNO. 5. ACCENT STRIP ON COLUMN CLADDING AT BAY 2 AND BAY 7 TO BE PAINTED C-4. 6. LOCATE DRAIN CLEANOUT AT COLUMN SIDE CLEAR FROM WINDSCREEN, TVM, OR ANY OBJECTS ON THE PLATFORM FOR ACCESS. EXTERIOR COLOR NOTES: GENERAL NOTES: 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 1/20/2025 11:01:31 AM BT120 0 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED904 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE CONDUIT RACEWAY DETAILS PLATFORM12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1 1/2" = 1'-0" BT120-AEX713 CONDUIT RACEWAY @ LOWER SOFIT A SCALE: 1 1/2" = 1'-0" CONDUIT RACEWAY ENLARGED DETAIL B BT120-AEX713 SCALE: 3" = 1'-0" BT120-AEE814 OPENING DETAIL @ SOFFIT 1 4 4 RTA/CN 0205-24 GUTTER METAL COLUMN COVER, C-1, TYP. CLERESTORY ALUMINUM STOREFRONT FRAME SF-1 & ART GLASS APA-1, TYP STRUCTURAL COLUMN STRUCTURAL BEAM OVERFLOW2" BRAKE SHAPED ALUMINUM TO MATCH SF-1 FINISH JOINT SEALANT AND PROVIDE DISSIMILAR METAL PROTECTION, TYP STEEL TRIM TO MATCH COLUMN COVER FINISH, TYP 4" JOINT SEALANT AND PROVIDE DISSIMILAR METAL PROTECTION, TYP 1.1 1.2 7"22'-10"7" EQ EQ EQ EQ EQ A - B - 2 -V.I.F. 2' - 5" STANDING SEAM METAL ROOFING METAL DECK UPPER STRUCTURAL BEAM GUTTER 3" ROOF SHEATHING STRUCTURAL COLUMN AT BACKGROUND METAL ANGLE, TYP 3" DIA. DOWNSPOUT BEYOND CLERESTORY ALUMINUM STOREFRONT FRAME SF-1 & ART GLAZING APA-1 STEEL CLADDING & FLASHING, FINISH TO MATCH FASCIA, C-2, PROVIDE DISSIMILAR METAL PROTECTION, TYP METAL ROOFING METAL FLASHING METAL DECK ROOF SHEATHING ALUMINUM STOREFRONT FRAME SF-1 FOR APA-1 LOWER STRUCTURAL BEAM STRUCTURAL COLUMN AT BACKGROUND 4" STEEL CLADDING, C-1, TYP 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:30:58 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED912 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE CLERESTORY DETAILS PLATFORM12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3" = 1'-0" CLERESTORY - JAMB 2 - SCALE: 3/4" = 1'-0" BT120-AEX712 CLERESTORY 1 SCALE: 3" = 1'-0" CLERESTORY - HEAD A -SCALE: 3" = 1'-0" CLERESTORY - SILL B - 4 RTA/CN 0205-24 PAINTED STEEL MOUNTING PLATE & SUPPORT ROD PROVIDED BY CONTRACTOR, TYP 6" 1"4"1" CLCL 7" 6" SEE 2/BT120-SGD113 METAL SOFFIT 6" 6"X 12" REMOVABLE SHEET METAL TRIM FOR ANCHOR ACCESS WHERE BRACKET OCCURS, TYP SOFFIT PANEL TRIM 1 3/4"1/4" VERTICAL STEEL CHANNEL BAR WELDED TO COLUMN FOR HORIZONTAL ANGLE MOUNTING METAL COLUMN COVER BOTTOM OF SIGN ST SIGNAGE (NOT SHOWN ON ELEVATION VIEW FOR CLARITY) ADJUST HORIZONTAL ANGLE LENGTH TO ACCOMODATE DUAL SIGNS MOUNTING AS NEEDED, TYP. ADJUST HORIZONTAL ANGLE LENGTH TO ACCOMODATE DUAL SIGNS MOUNTING AS NEEDED, TYP. FACE OF STRUCTRUAL COLUMN 2'-0" TYP TOP OF PLATFORM OVERFLOW DRAIN ROOF DOWNSPOUT SECTION ELEVATION COORDINATE WITH SIGNAGE WIDTH 1'-7" 3'-10" COORD WITH SIGN HEIGHT 6" 1'-3"1'-1" 1 1/2" 1/2" 3'-0" 1'-2 1/4" DOUBLE NUTS ST SIGNAGE BASE FOUR (4) 1/2" DIA. x 4 1/2" MIN. EMBEDED STAINLESS STEEL ANCHOR BOLTS AND PENTA- NUT SET WITH ST PROVIDED TEMPLATE MIN. 4 1/2" REBAR (3) #4 EACH WAY CLEARANCE 3" MIN CL EQ EQ 8" 1'-3"1'-1" 1 1/2" 1/2" 1'-4 1/4" DOUBLE NUTS FOUR (4) 5/8" DIA. x 6" MIN. EMBEDED STAINLESS STEEL ANCHOR BOLTS AND PENTA- NUT SET WITH ST PROVIDED TEMPLATE ST SIGNAGE BASE 4'-0". EMBED. 6" MIN REBAR (3) #4 EACH WAY CLEARANCE 3" MIN CL EQ EQ 8" 1" 1" 1/2" 3'-0" 1'-2 1/4" DOUBLE NUTS ST SIGN POLE AND MOUNTING ACESSORY EMBED 6" MIN REBAR (3) #4 EACH WAY CLEARANCE 3" MIN CL EQ EQ STAINLESS STEEL ANCHOR BOLTS AND NUTS SET WITH ST PROVIDED TEMPLATE 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:39 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED914 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE SIGNAGE DETAILS PLATFORMJC DH CC JC DH CC 3" = 1' -0" 12/10/2024 433ISSUED FOR BID12/10/2024 SCALE: 3" = 1'-0" HANGING SIGNAGE A SCALE: 3" = 1'-0" SIGNAGE AT COLUMN D SCALE: 3" = 1'-0" SIGNAGE (C3) AT FREESTANDING POLE C SCALE: 3" = 1'-0" SIGNAGE (B6) AT FREESTANDING POLE B SCALE: 3" = 1'-0" SIGNAGE (E1) AT FREESTANDING POLE E 1 06/13/2025 ADDENDUM #1 1 1 1 1 1 1 8" 1'-0" 1" 1" PT 1X2X3 TAB TO MATCH WINDSCREEN FRAME, PROVIDE DISSIMILAR METAL PROTECTION, TYP LINE OF WINDSCREEN, NOT SHOWN FOR CLARITY 4" x 4" STRUCTURAL FRAME NIC 3D VIEW ELEVATION VIEW 2'-0 "2'- 0 " 3/4' x 0.02" STAINLESS STEEL STRAP WITH TIGHTENING CLIP AND FLARED LEG BRACKET EQ EQ CL 3'-6" ST SIGNAGE SIGN POST, 4x4 SQUARE STEEL TUBE, PAINTED C-1 12" x 12" x 3/8" METAL PLATE, PAINTED C-1 6" 10" FOUR (4) 1/2" DIA. x 4 1/2" MIN. EMBEDED STAINLESS STEEL ANCHOR BOLTS AND PENTA-NUT SET REBAR (3) #4 EACH WAY CLEARANCE 3" MIN CL 10'-0". 8'-0". 5"5" 3/16 SIGN AND MOUNTING BRACKET TO THE POST BY SOUND TRANSIT 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:39 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED915 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE SIGNAGE DETAILS PLATFORMJC DH CC JC DH CC 12/10/2024 434ISSUED FOR BID12/10/2024 SCALE: 3" = 1'-0" F3 MOUNTING DETAILS B SCALE: 3" = 1'-0" SIGNAGE AT RAILING A SCALE: 1 1/2" = 1'-0" SIGNAGE - BREAKAWAY POST C 1 1 06/13/2025 ADDENDUM #1 1 1 1 1 45° 2" 3"4" 7 5 ° 11" 2" LADDER SECURE POINT 1" SQUARE BENT BAR FILLET WELDS ON BOTH SIDES TO BE DESIGNED FOR 300 LBS PROVIDE SEALANT WHERE STEEL BARS PENETRATE METAL FASCIA 1" SQUARE STIFFENER BAR, 1 3/4" LONG METAL FASCIA METAL SOFFIT METAL STANDING SEAM ROOFING LADDER SECURE POINT STEEL SHALL RECEIVE HIGH PERFORMANCE COATING (HPC), UNLESS SST. NOTE: 3/16 3/16 1/2" STIFFENER PLATE 1" (3) SIDES 3/16 (3) SIDES3/16 NS & FS 3/16 3/16 STRUCTURAL BEAM UPPER AND LOWER CANOPY 4'-6". CL CL CL 9 1/2" 1 3/4" STRUCTURAL BEAM METAL FASCIA 2" x 3/8" STIFFENER PLATE 1'-10" 2" 1" SQUARE BAR W/ STIFFENER PLATE 1" 1" EQ EQ B BT120-AED916 1" 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:31:01 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED916 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE CANOPY DETAILS PLATFORM12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3" = 1'-0" BT120-AED916 LADDER TIE-OFF -SECTION B SCALE: 3" = 1'-0" BT120-ARP312 LADDER TIE-OFF - ELEVATION A 4 RTA/CN 0205-24 P 1.A 1.B 1.C 1.E 1.D 1.F 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.15 1 BT120-ACP212 1 BT120-ACP213 1 BT120-ACP214 1 1 1 1 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:41 PM 1/16" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ACP211 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE REFLECTED CEILING PLAN PLATFORMJC DH CC JC DH CC 12/10/2024 436ISSUED FOR BID12/10/2024 SCALE IN FEET 8 1616 320 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 1 P 1.A 1.B 1.C A BT120-AEX712 1.1 1.2 1.3 1.4 A BT120-AEX711 B BT120-AEE812 A BT120-AEE812 1 BT120-APD101 A BT120-AEE811 1'-0"11'-0"16'-0"16'-0"16'-0"13'-0"1'-0" 4'-0" 4'-0" 2' - 11"2' - 4 1/2"5' - 6 1/2"2' - 11" ACCESS PANEL VMS SIGN METAL SOFFIT PANEL CAMERA LIGHT FIXTURE STRIDE PYLON LEGEND LIGHT FIXTURE SIGNAGE -SEE SIGNAGE PLAN VMS LIGHT FIXTURE 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:41 PM 1/8" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ACP212 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE REFLECTED CEILING PLAN PLATFORM - SECTOR A JC DH CC JC DH CC 12/10/2024 437ISSUED FOR BID12/10/2024 SCALE IN FEET 4 0 88 16 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 1 1.A 1.B 1.C 1.5 1.6 1.7 A BT120-AEE813 1'-0"13'-0"22'-0"13'-0"9" B BT120-AEE813 4'-0" 4'-0" DIGITAL SIGN -STRIDE KCM RTIS 8' - 0"2' - 4 1/2"8' - 0" ACCESS PANEL VMS SIGN METAL SOFFIT PANEL CAMERA LIGHT FIXTURE STRIDE PYLON LEGEND LIGHT FIXTURE SIGNAGE -SEE SIGNAGE PLAN VMS LIGHT FIXTURE 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:42 PM 1/8" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ACP213 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE REFLECTED CEILING PLAN PLATFORM - SECTOR B JC DH CC JC DH CC 12/10/2024 438ISSUED FOR BID12/10/2024 SCALE IN FEET 4 0 88 16 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 1 1 ACCESS PANEL VMS SIGN METAL SOFFIT PANEL CAMERA LIGHT FIXTURE STRIDE PYLON LEGEND LIGHT FIXTURE SIGNAGE -SEE SIGNAGE PLAN VMS LIGHT FIXTURE 1.E 1.D 1.F 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.15 10'-8"12'-0"12'-0"12'-0"12'-0"12'-0"12'-0"12'-0"12'-0"12'-0"12'-0"12'-0"12'-0"12'-0"2'-10" 4'-0" 4'-0" 8' - 0"8' - 0"8' - 0"8' - 0"8' - 0"8' - 0"8' - 0"KCM RTIS, TYP. 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:43 PM 1/8" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ACP214 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE REFLECTED CEILING PLAN PLATFORM - SECTOR C JC DH CC JC DH CC 12/10/2024 439ISSUED FOR BID12/10/2024 SCALE IN FEET 4 0 88 16 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 1 1 06/13/2025 ADDENDUM #1 1 1 1 AT S 2 CR DSFIXFIXFI X FI X FI X FI X FIXFIXFIX CR CRCRCR CRPTZPTZFIXFIXCR CR 2 2 W W W2W2 2 P C 74 SF OPERATOR RESTROOM BT120L1204 74 SF OPERATOR RESTROOM BT120L1205 2.A 2.A 2.G 2.7 2.D 2.32.1 2.J 2.E 2.112.102.92.82.62.52.4 75 SF OPERATOR RESTROOM BT120L1206 74 SF OPERATOR RESTROOM BT120L1207 113 SF JANITOR BT120L1203 112 SF LACTATION ROOM BT120L1202 409 SF TELECOM BT120L1208351 SF ELECTRICAL BT120L1209 450 SF STORAGE 1 BT120L1210 257 SF SECURITY BLDG BT120L1200 2.B 2.F 15'-5" 10'-0" 12'-0" 12'-0" 8'-1"6'-0"21'-4"24'-9"17'-3"17'-4"27'-9"8'-11"15'-5" 21'-5" 1 BT120-APD222 1 BT120-APD223 1 BT120-APD224 1 BT120-APD225 A BT120-AEE822 A BT120-AEE821 B BT120-AEE821 D BT120-AEE822 B BT120-AEE822 C BT120-AEE822 ROOF OVERHANG OUTLINE OF OVERHANG ABOVE ROOF ABOVE E BT120-AEE822 B BT120-AIX724 A BT120-AIX722 A BT120-AIX723 A BT120-AIX724 C BT120-AIX723 B BT120-AIX723 69 SF SEC STORAGE BT120L1201 26'-8"32'-8"36'-8" A BT120-AIX721 2.C 2.2 1 BT120-APP261 PLANTER AREA REFUSE AND RECYCLING AREA A BT120-AES911 15'-4" 2'-0" TRANLUCENT PANEL SYSTEM, TYP. 8" 2.H 1 BT120-AID909 9 1/2" 9 1/2" DS DS 6'-4" 1'-1" 8" 36" 43 1/4" DOWNSPOUT, TYP OUTLINE OF OVERHANG ABOVE AED CONTRACTOR FURNISHED CONTRACTOR INSTALLED SHEET LEGEND FLOOR DRAIN DS DOWN SPOUT CFCI FURNITURE, APPLIANCE: GENERAL NOTES: 1. SEE MECHANICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 2. SEE ELECTICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 3. SEE TELECOM DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 4. SEE ROOM FINISH SCHEDULE FOR MATERIALS AND FINISHES. 5. CONTRACTOR TO PROCURE AND PROVIDE FURNITURE AND APPLIANCE 6. FURNITURE: A. OFFICE CHAIR (OF-7) B. FILE CABINET (OF-6). C. SOFA/LOUNGE CHAIR (OF-8), D. END TABLE (OF-9), E. WASTE PAPER BASKET (OF-13), F. FOLDING BENCH WORK BENCH (OF-10) 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:44 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APP221 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE OVERALL FLOOR PLAN CORE FACILITYJC DH CC JC DH CC 3/16" = 1' -0" 12/10/2024 440ISSUED FOR BID12/10/2024 SCALE IN FEET 048 8 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 1 1 2 CRFIXFIXCRPTZPTZCR 2 2 2.A 2.D 2.E 2.112.102.92.8 2.B 2.F A BT120-AEE822 D BT120-AEE822 B BT120-AEE822 SECURITY BLDG BT120L1200 BT120-AIE821 A BT120-AIE821 BBT120-AIE821 C BT120-AIE821DBT120-AIE821 21'-4"6'-0"8'-1" BT120L1200A 1'-4" W5.2 W1 W3 23'-4" A BT120-AIX723 A BT120-AIX721 2.C BT120L1200B W5.2 W5.2 W1 W5.3 W2 4'-0" 4'-0" 9'-4" 6'-0" 6'-0" 5'-4"5'-4" BT120L1201 3 BT120-AED905 2 BT120-AED905 1 BT120-AED905 A BT120-AES911 E BT120-AES911 F BT120-AES911 DOWNSPOUT TO CENTER OF DOWNSPOUT 7'-9" DOWNSPOUT DOWNSPOUT 8" 56" 56" 192" 6'x4' ENTRANCE FLOOR MATS AND FRAME OF-7, TYP. PLDC, TYP. SSCT AED GENERAL NOTES: 1. SEE MECHANICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 2. SEE ELECTICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 3. SEE TELECOM DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 4. SEE ROOM FINISH SCHEDULE FOR MATERIALS AND FINISHES. 5. CONTRACTOR TO PROCURE AND PROVIDE FURNITURE AND APPLIANCE 6. FURNITURE: A. OFFICE CHAIR (OF-7) B. FILE CABINET (OF-6). C. SOFA/LOUNGE CHAIR (OF-8), D. END TABLE (OF-9), E. WASTE PAPER BASKET (OF-13), F. FOLDING BENCH WORK BENCH (OF-10) 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:45 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APD222 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE ENLARGED FLOOR PLAN CORE FACILITY - SECTOR E JC DH CC JC DH CC 3/8" = 1'-0" 12/10/2024 441ISSUED FOR BID12/10/2024 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE IN FEET 024 4 1 06/13/2025 ADDENDUM #1 1 1 1 1 FIXFI XFIXCR CR 2.A 2.7 2.D 2.E 2.82.62.5 2.5 2.B LACTATION ROOM BT120L1202 JANITOR BT120L1203 OPERATOR RESTROOM BT120L1204 OPERATOR RESTROOM BT120L1205 OPERATOR RESTROOM BT120L1206 OPERATOR RESTROOM BT120L1207 BT120L1203 BT120L1201 BT120-AIE822 D BT120-AIE822 BT120-AIE822 H BT120-AIE822 BT120-AIE823 E BT120-AIE823 BT120-AIE823 J BT120-AIE823BT120-AIE824 D BT120-AIE824BT120-AIE824 H BT120-AIE824 EBT120-AIE822 ABT120-AIE822CBT120-AIE822 B BT120-AIE822 BBT120-AIE823 C BT120-AIE823DBT120-AIE823 FBT120-AIE823 G BT120-AIE823HBT120-AIE823ABT120-AIE824 B BT120-AIE824CBT120-AIE824EBT120-AIE824 F BT120-AIE824GBT120-AIE824 F BT120-AIE822GBT120-AIE822 A BT120-AIX722 12'-0"3'-4"2'-0"3'-4"6'-0"8"3'-4"8'-0"3'-4"2'-0"3'-4"8'-0"3'-4"8" 8'-0" 3'-4" C BT120-AIX723 B BT120-AIX723 SEC STORAGE BT120L1201 A BT120-AIX721 2.C BT120L1202 BT120L1204BT120L1205BT120L1206BT120L1207 BT120-AIE823 ABT120-AIE823 2'-0" 10'-9" 2'-8" PLANTER BOX A A A BBABB B BT120-AES911 DRAIN, TYP. 24'-9"17'-3"17'-4" WMP-6 FOR ARCHITECTURAL GREEN SCREEN, TYP.8"5'-8"8" DOWNSPOUT, TYP. DOWNSPOUT, TYP. 1 BT120-AID911 1'-6" OF-9 OF-8, TYP. SSCT MOP SINK REFRIGERATOR 4' W x 2' D BASE CABINET GENERAL NOTES: 1. SEE MECHANICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 2. SEE ELECTICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 3. SEE TELECOM DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 4. SEE ROOM FINISH SCHEDULE FOR MATERIALS AND FINISHES. 5. CONTRACTOR TO PROCURE AND PROVIDE FURNITURE AND APPLIANCE 6. FURNITURE: A. OFFICE CHAIR (OF-7) B. FILE CABINET (OF-6). C. SOFA/LOUNGE CHAIR (OF-8), D. END TABLE (OF-9), E. WASTE PAPER BASKET (OF-13), F. FOLDING BENCH WORK BENCH (OF-10) 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:46 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APD223 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE ENLARGED FLOOR PLAN CORE FACILITY - SECTOR F JC DH CC JC DH CC 3/8" = 1'-0" 12/10/2024 442ISSUED FOR BID12/10/2024 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE IN FEET 024 4 1 06/13/2025 ADDENDUM #1 1 1 1 1 FI X FI X FIX CRCRCRFIXFIXWWW2W22 2.A 2.D 2.32.1 2.E 2.52.4 2.B 351 SF ELECTRICAL BT120L1209 409 SF TELECOM BT120L1208 CHAIN LINK FENCE 15'-5"8'-11"27'-9" 2'-0" 10'-9" 2'-8" BT120L1209 BT120L1208B BT120L1208A 2'-8"4'-8"11'-4"5'-4"6'-8"6'-0" B BT120-AIX724 A BT120-AIX724 A BT120-AIX721 2.C 2.2 7'-8 1/2"2'-8"2'-8"2'-8"19'-4"2'-8"2'-8"2'-8"9'-0 1/2" BT 1 2 0 L 1 2 0 7 5 BT120-AED905 A1 A 1 BT120-AID909 OF-10, FOLDING WORK BENCH W8 W8 W8 W8W8W8W8W8 W6 8"DOWNSPOUT, TYP. 2'-0" DOWNSPOUT, TYP. C BT120-AID912 GENERAL NOTES: 1. SEE MECHANICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 2. SEE ELECTICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 3. SEE TELECOM DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 4. SEE ROOM FINISH SCHEDULE FOR MATERIALS AND FINISHES. 5. CONTRACTOR TO PROCURE AND PROVIDE FURNITURE AND APPLIANCE 6. FURNITURE: A. OFFICE CHAIR (OF-7) B. FILE CABINET (OF-6). C. SOFA/LOUNGE CHAIR (OF-8), D. END TABLE (OF-9), E. WASTE PAPER BASKET (OF-13), F. FOLDING BENCH WORK BENCH (OF-10) 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:46 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APD224 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE ENLARGED FLOOR PLAN CORE FACILITY - SECTOR G JC DH CC JC DH CC 3/8" = 1'-0" 12/10/2024 443ISSUED FOR BID12/10/2024 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE IN FEET 024 4 1 06/13/2025 ADDENDUM #1 1 1 1 DS FIXFIXFIX CR W 2.32.1 2.J 2.E BT120L1210A BT 1 2 0 L 1 2 1 0 B STORAGE 1 BT120L1210 B BT120-AIX724 10'-8" 34'-0" 16'-0" 2.2 1'-4"14'-1" 2'-8" 11 1/2" 12'-4 1/2" 3'-4" 2'-8" 8'-0" 2'-0" W5.1 W5.1 W5.1 W5.1 1'-4" 2'-4" DOWNSPOUT, TYP. 4 BT120-AED905 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:47 PM 3/8" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APD225 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE ENLARGED FLOOR PLAN CORE FACILITY - SECTOR H JC DH CC JC DH CC 12/10/2024 444ISSUED FOR BID12/10/2024 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE IN FEET 024 4 1 06/13/2025 ADDENDUM #1 1 1 1 2.72.32.1 2.J 2.112.102.92.82.62.52.4 2.F 1/2" / 12" OVERHANG BELOW OVERHANG BELOW 15'-5"8'-11"27'-9"17'-4"17'-3"24'-9"27'-4"8'-1" ROOF BELOW 2'-0" 10'-9" 2'-8" 6'-0" ROOF BELOW (TYPE 2 ROOF ASSEMBLY @ STORAGE ROOM) 16'-0" 11 1/2" GUTTER B BT120-AIX724 A BT120-AIX722 A BT120-AIX723 A BT120-AIX724 C BT120-AIX723 B BT120-AIX723 A BT120-AIX721 2.C 2.2 A BT120-AED906 STEEL FASCIA, C-2, TYP. METAL STANDING SEAM ROOFING METAL GUTTER OPEN 2 BT120-ARP321 3 BT120-ARP321 D BT120-AED907 C BT120-AED907 C BT120-AED908 C BT120-AID909 C BT120-AED906 C BT120-AED906 DOWNSPOUT, TYP.GUTTERDOWNSPOUT, TYP. DOWNSPOUT, TYP. 6'-1" CL 1/ 2 " / 1 2 " BIRD CONTROL DEVICES, BCD-2, TYP. 2.D 2.32.1 2.E 2.2 MAIN ROOF OVERHANG 1/2" / 12" 2.A 2.D 2.E 2.112.102.9 2.B 2.F 2.C MAIN ROOF OVERHANG, TYP. METAL OVERHANG6'-0"8'-1" METAL OVERHANG . . C BT120-AED907 ROOF AT SECURITY BUILDING C BT120-AED906 A BT120-AED906 1/2" / 12" C-1: RAILWAY GRAY, CMYK 0/0/0/80 C-2: LAND GRAY, CMYK 0/0/0/6 C-3: WAVE TEAL, CMYK 92/23/22/32 C-4: KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U 1. ALL BENCHES ON PLATFORM ARE BENCH-1 TYPE, TYP, UNO. 2. ALL LEAN RAILS ARE LR-1, TYP. 3. ART GLASS UNIT, APA-1 SHALL BE PROVIDED BY OTHERS AT CLERESTORIES AND UPPER PORTION OF WINDSCREEN. CONTRACTOR TO COORDINATE WITH SUPPLIER TO ASSEMBLY UNIT TO ALUMINUM STOREFRONT SYSTEM SF-1 FOR INSTALLATION. 4. ACCENT STRIPS ON COLUMN CLADDINGS ARE PAINTED C-3, TYP, UNO. 5. ACCENT STRIP ON COLUMN CLADDING AT BAY 2 AND BAY 7 TO BE PAINTED C-4. 6. LOCATE DRAIN CLEANOUT AT COLUMN SIDE CLEAR FROM WINDSCREEN, TVM, OR ANY OBJECTS ON THE PLATFORM FOR ACCESS. EXTERIOR COLOR NOTES: GENERAL NOTES: ROOF NOTES: 1. ROOF ASSEMBLIES PER SHEET BT120-AED908 2. ROOF ASSEMBLY TYPE 1 -BT120L1200 -BT120L1201 -BT120L1202 -BT120L1203 -BT120L1204 -BT120L1205 -BT120L1206 -BT120L1207 -BT120L1208 -BT120L1209 3. ROOF ASSEMBLY TYPE 2 -BT120L1210 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:49 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ARP321 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE OVERALL ROOF PLAN CORE FACILITYJC DH CC JC DH CC 12/10/2024 445ISSUED FOR BID12/10/2024 SCALE: 3/16" = 1'-0"BT120-AED905 BT120-ARP341 CORE FACILITY ROOF PLAN 1 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY NSCALE: 3/16" = 1'-0" CORE FACILITY ROOF PLAN @ STORAGE 2 BT120-ARP321 SCALE: 1/4" = 1'-0" CORE FACILITY ROOF PLAN @ SECURITY BLGD.3 BT120-ARP321 1 06/13/2025 ADDENDUM #1 1 1 1 1 1 1 1 1 1 CORE FACILITY 28' -2" CORE FACILITY-ROOF 41' -2" 2.72.32.1 2.112.102.92.82.62.52.4 B BT120-AIX724 A BT120-AIX722 A BT120-AIX723 A BT120-AIX724 C BT120-AIX723 B BT120-AIX723 2.2 FIELD CMU, TYP. COPING, C-1, TYP. C-2 TOP & EDGES, C-5 SOFFIT, TYP METAL PICKET FENCE TRANSLUCENT PANEL TYPE I.CLOSED CIRCUIT TELEVISION CAMERA, TYP. STEEL FASCIA, C-2, TYP. TRANSLUCENT PANEL SYSTEM, TYP. SECURITY WINDOWS, TYP. ACCENT CMU ACCENT CMU ACCENT CMU, TYP. 1'-4"14'-1"8'-11"27'-9"17'-4"17'-3"24'-9"21'-4"6'-0"8'-1" BT120L1209 BT120L1208B BT120L1208A BT120L1207 BT120L1206 BT120L1205 BT120L1204 BT120L1203 BT120L1202 W4 W5.2 W5.2 LIGHT FIXTURE SOFFIT LVR-1 W/ DAMPER, TYPCOPING, C-1, TYP. FORMED METAL WALLPANEL, C-2, TYP. FORMED METAL WALL PANEL, TYP. B BT120-AID909 BRAKE SHAPE METAL C-1, TYP W7 CORE FACILITY 28' -2" CORE FACILITY-ROOF 41' -2" 2.7 2.3 2.12.11 2.10 2.9 2.8 2.6 2.5 2.4 B BT120-AIX724 A BT120-AIX722 A BT120-AIX723 A BT120-AIX724 C BT120-AIX723 B BT120-AIX723 2.2 TRANSLUCENT PANEL SYSTEM, TYP.METAL DOOR W/ VISION PANEL SECURITY WINDOW TRANSLUCENT PANEL TYPE I, TYP. LANDSCAPE PLANTER EDGE METAL ROOF METAL FASCIA, C-2, TYP. ARCHITECTURAL GREEN WALL, WMP-6, C-2, TYP. ACCENT CMU, TYP. METAL PICKET FENCE, C-1, TYP. FIELD CMU, TYP. ACCESS PANEL, WMP-5, , C-2, TYP.STEEL COPING, C-1, TYP C-2 TOP & EDGES, C-5 SOFFIT, TYP FIELD CMU METAL FRAME, HPC-2, C-1 1'-4"14'-1"8'-11"27'-9"17'-4"17'-3"24'-9"21'-4"6'-0"8'-1" DOWNSPOUT, TYP. DOWNSPOUT, C-1, TYP. DOWNSPOUT ACCENT CMU W8 W8 W8 W8 W8 W8 W8 W8 W5.2 W4 C BT120-AID909 1 BT120-AID909 10'-0" BT120L1200A STEEL GRATING, WMP-5, SCREEN, C-2, TYP LVR-1, BEHIND METAL SCREEN B BT120-AID909 BRAKE SHAPE METAL C-1, TYP STEEL TRIM AT JAMB, C-3, TYP STEEL HEAD FLASHING, C-1, TYP 2' - 0" 8"1' - 6" 8" 1' - 4" WALL HYDRANT 6'-4" 2'-8"4'-0"2'-0"4'-0"4'-0"4'-0"4'-0"4'-8"4'-0"4'-0"4'-0"5'-4"4'-0"7'-8 1/2" TYP 7'-7" 4'-0" 7'-6" 19'-3"4'-0" 2'-7"4'-0"2'-0"4'-0"4'-0"8'-0"4'-8"8'-0"4'-0"5'-4"4'-0"4'-0"4'-8" 7'-4" EQEQ EQEQEQEQEQEQ EQEQ EQEQ STEEL SUPPORT FRAMING, C-2, TYP. CONTROL JOINT BEHING DOWNSPOUT, TYP. SEE SHEET BT120-AID900 FOR SCREEN DETAILS EXTERIOR COLOR NOTES: C-1: RAILWAY GRAY, CMYK 0/0/0/80 C-2: LAND GRAY, CMYK 0/0/0/6 C-3: WAVE TEAL, CMYK 92/23/22/32 C-4: KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U C-5: HI-LITE YELLOW, CMYK 0/32/95/0 GENERAL NOTES: 1. FIELD CMU: CMU-3, 4" THICK CMU VENEER, TYP. 2. ACCENT CMU: CMU-4, 4" THICK CMU VENEER, TYP. 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:52 PM As indicated BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEE821 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR ELEVATIONS CORE FACILITYJC DH CC JC DH CC 3/16" = 1'-0" 12/10/2024 446ISSUED FOR BID12/10/2024 SCALE IN FEET 048 8 SCALE: 3/16" = 1'-0" BT120-APP221 EAST ELEVATION - CORE FACILITY A SCALE: 3/16" = 1'-0" BT120-APP221 WEST ELEVATION - CORE FACILITY B WINDOW TO WALL RATIO AT CORE FACILITY (SF/SF) N: 108 / 582 E: 315 / 1,450 S: 60 / 651 W:92 / 1,380 WINDOW TO WALL RATIO AT SECURITY OFFICE (SF/SF) N: 38 / 282 E: 32 / 185 S: 67 / 300 W:46 / 185 GENERAL NOTE FOR BUILDING ENVELOPE: 1. PROJECT CLOSE OUT DOCUMENTATION SHALL INCLUDE ENVELOPE RECORD CONSTRUCTION DOCUMENTS, APPLICABLE CALCULATIONS, WSEC ENVELOPE COMPLIANCE REPORTS, FENESTRATION NFRC RATING CERTIFICATES, AND A THERMAL ENVELOPE CERTIFICATE. 2. THE THERMAL ENVELOPE CERTIFICATE IN THE PROJECT CLOSE OUT DOCUMENT SHALL COVERS THE RATED R- VALUES OF ALL OPAQUE ASSEMBLY INSULATION, U-FACTORS & SHGCS FOR ALL FENESTRATION ASSEMBLIES. 1 06/13/2025 ADDENDUM #1 1 1 1 1 CORE FACILITY 28' -2" 2.A 2.G CORE FACILITY-ROOF 41' -2" 2.D2.E 2.B2.F A BT120-AIX721 2.C C-2 TOP & EDGES, C-5 SOFFIT, TYP FIELD CMU, TYP. DOWNSPOUT TO LOWER ROOF SECURITY WINDOW, TYP. METAL COPING AT LOWER ROOF METAL FASCIA METAL ROOF ACCENT CMU 2'-0"2'-0"8'-9"2'-8"6'-0" C BT120-AED907 12'-8 1/2" 4'-0"14'-5" 11'-6 1/4" 13'-6 1/2" W1 W5.3 CORE FACILITY 28' -2" 2.A CORE FACILITY-ROOF 41' -2" 2.E 2.F2.C C-2 TOP & EDGES, C-5 SOFFIT, TYP SECURITY WINDOW, TYP. METAL DOOR W/ VISION PANEL WINDOW, TYP. METAL PICKET FENCE TRANSLUCENT PANEL METAL OVERHANG DOWNPOUT 4'-0"11'-5"6'-0" ACCENT CMU, TYP. DOWNSPOUT BEYOND FROM MAIN ROOF. METAL GUTTER C BT120-AED907 DOWNSPOUT, C-1, TYP. GUTTER W1W3W2 BT120L1200B 3'-4" METAL ROOF F BT120-AES911 OPP, SIM CORE FACILITY 28' -2" 2.A CORE FACILITY-ROOF 41' -2" 2.D2.E 2.B2.C DOWNSPOUT, C-1, TYP. CONCRETE PLANTER BOX MECHANICAL SCREEN METAL MESH METAL FASCIA, TYP. METAL ROOF METAL DOOR, TYP. TRANSLUCENT PANEL TYPE I METAL PICKET FENCE FIELD CMU, TYP. 4'-0"11'-5" BT120L1201 B BT120-AID909 WMP-6, STEEL GRATING, C-1, TYP CORE FACILITY 28' -2" 2.A2.G CORE FACILITY-ROOF 41' -2" 2.J 2.E A BT120-AED906 METAL OVERHEAD DOOR, TYP. CLOSED CIRCUIT TELEVISION CAMERA, TYP. METAL GUTTER, C-1, TYP. METAL DOOR, TYP. DOWNSPOUT FIELD CMU, TYP. METAL ROOF METAL FASCIA 15'-5"10'-0"12'-0"12'-0" ACCENT CMU METAL ROOF DOWNSPOUT, C-1, TYP. BT120L1210B 2.H METAL GUTTER C BT120-AED908 BT120L1210A 11'-0" T.O.M CORE FACILITY 28' -2" 2.A 2.G CORE FACILITY-ROOF 41' -2" 2.J2.E2.C A BT120-AED906 TRANSLUCENT PANEL SYSTEM, TYP. FIELD CMU, TYP. TRANSLUCENT PANEL SYSTEM, TYP. ACCENT CMU DOWNSPOUT CLOSED CIRCUIT TELEVISION CAMERA, TYP. 4'-0"11'-5"10'-0"12'-0"12'-0" MECHANICAL METAL MESH SCREEN BEYOND CLOSED CIRCUIT TELEVISION CAMERA, TYP. D BT120-AED907 W6 W5.1 W5.1 W5.1 W5.1 8'-0" 2.H 13'-6 1/2" 14'-5" 12'-0" 7'-4" 8'-8" T.O.M. STEEL FLASHING, C-1, TYP. STEEL TRIM AT JAMB, C-3, TYP. EXTERIOR COLOR NOTES: C-1: RAILWAY GRAY, CMYK 0/0/0/80 C-2: LAND GRAY, CMYK 0/0/0/6 C-3: WAVE TEAL, CMYK 92/23/22/32 C-4: KCM RAPID RIDE PANTONE 7427, 7427 C, 7427 U C-5: HI-LITE YELLOW, CMYK 0/32/95/0 GENERAL NOTES: 1. FIELD CMU: CMU-3, 4" THICK CMU VENEER, TYP. 2. ACCENT CMU: CMU-4, 4" THICK CMU VENEER, TYP. 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 1/20/2025 11:01:53 AM BT120 0 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEE822 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR ELEVATIONS CORE FACILITY12/10/2024 J.C. D.H. C.C. 3/16" = 1'-0" ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE IN FEET 048 8 SCALE: 3/16" = 1'-0" BT120-APP221 NORTH ELEVATION I - CORE FACILITY A SCALE: 3/16" = 1'-0" BT120-APP221 SOUTH ELEVATION I - CORE FACILITY D SCALE: 3/16" = 1'-0" BT120-APP221 NORTH ELEVATION II - CORE FACILITY B SCALE: 3/16" = 1'-0" BT120-APP221 NORTH ELEVATION III - CORE FACILITY C SCALE: 3/16" = 1'-0" BT120-APP221 SOUTH ELEVATION II - CORE FACILITY E WINDOW TO WALL RATIO AT CORE FACILITY (SF/SF) N: 108 / 582 E: 315 / 1,450 S: 60 / 651 W:92 / 1,380 WINDOW TO WALL RATIO AT SECURITY OFFICE (SF/SF) N: 38 / 282 E: 32 / 185 S: 67 / 300 W:46 / 185 44 44 RTA/CN 0205-24 CORE FACILITY 28' -2" CORE FACILITY-ROOF 41' -2" 2.72.3 2.1 2.112.102.92.82.62.52.4 B BT120-AIX724 A BT120-AIX722 A BT120-AIX723 A BT120-AIX724 C BT120-AIX723 B BT120-AIX723 2.2 ELECTRICAL BT120L1209 TELECOM BT120L1208 OPERATOR RESTROOM BT120L1207 OPERATOR RESTROOM BT120L1206 OPERATOR RESTROOM BT120L1205 OPERATOR RESTROOM BT120L1204 JANITOR BT120L1203 LACTATION ROOM BT120L1202 SEC STORAGE BT120L1201 SECURITY BLDG BT120L1200 B BT120-AED907 A BT120-AED905 C BT120-AID909 1 BT120-AID909 FULL HEIGHT METAL CHAIN LINK FENCE METAL FENCE E BT120-AED908 10'-7 1/2" 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:31:39 PM 3/16" = 1'-0" BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AIX721 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE BUILDING SECTIONS I CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3/16" = 1'-0" TRANSVERSE SECTION - CORE FACILITY A BT120-ARP221 SCALE IN FEET 048 8 448 RTA/CN 0205-24 CORE FACILITY 28' -2" 2.A CORE FACILITY-ROOF 41' -2" 2.D 2.E2.B A BT120-AIX725 B BT120-AIX725 2.C 2'-0" OPERATOR RESTROOM BT120L1205 8'-0" ARCHITECTURAL GREEN WALL DOWNSPOUT 8'-0" PLANTER EDGER 8" SEE WALL SECTION FORMED METAL WALL PANELS CLADDING, TYP CONTINUOUS AIR BARRIER GRAPHIC REPRESENATION FOR BUILDING ENVELOPE, SEE WALL SECTION FOR DETAIL BUILDING THERMAL ENVELOPE AIR LEAKAGE TEST 1. BUILDING AIR LEAKAGE TESTING SHALL BE PERFORMED PER ASTM C779 2. THE TARGET LEAKAGE RATE IS 0.25 CFM/FT2 (1.5 L/S*M2) AT 0.3 IN. WG (75 PA) 3. TESTED PORTIONS OF THE BUILDING SHALL INCLUDE ALL SPACES DIRECTLY UNDER THE ROOF, ALL SPACES THAT HAVE A BUILDING ENTRANCE, EXPOSED FLOOR, LOADING DOCK OR ARE BELOW GRADE PLANE, AND REPRESENTATIVE ABOVE- GRADE AREAS THAT TOTAL ≥25% OF THE BUILDING TOTAL ABOVE-GRADE WALL AREA; 4. THE WEIGHTED AVERAGE AIR LEAKAGE RATE OF THE BUILDING THERMAL ENVELOPE SHALL NOT EXCEED 0.25 CFM/FT2 (1.27 L/S*M2) WHEN MEASURED AT A PRESSURE DIFFERENTIAL OF 0.3 IN. WG (75 PA). 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:31:42 PM As indicated BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AIX722 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE BUILDING SECTIONS II CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3/4" = 1'-0" TRANVERSE SECTION - @ OPERATOR RESTROOM A BT120-ARP221 SCALE IN FEET 012 20488 449 RTA/CN 0205-24 GENERAL NOTES: 1. SEE MECHANICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 2. SEE ELECTICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 3. SEE TELECOM DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 4. SEE ROOM FINISH SCHEDULE FOR MATERIALS AND FINISHES. 5. CONTRACTOR TO PROCURE AND PROVIDE FURNITURE AND APPLIANCE 6. FURNITURE: A. OFFICE CHAIR (OF-7) B. FILE CABINET (OF-6). C. SOFA/LOUNGE CHAIR (OF-8), D. END TABLE (OF-9), E. WASTE PAPER BASKET (OF-13), F. FOLDING BENCH WORK BENCH (OF-10) CORE FACILITY 28' -2" 2.A CORE FACILITY-ROOF 41' -2" 2.D 2.E2.B 2.F2.C SECURITY BLDG BT120L1200 C BT120-AED907 A BT120-AED907 D BT120-AED908 E BT120-AED909 E BT120-AED906 CORE FACILITY 28' -2" CORE FACILITY-ROOF 41' -2" 2.D 2.E2.B 2.C LACTATION ROOM BT120L1202PLANTER PLANTER WALL CORE FACILITY 28' -2" 2.A CORE FACILITY-ROOF 41' -2" 2.D 2.E2.B 2.C JANITOR BT120L1203 B BT120-AED908 BCD-1 BCD-2 CONTINUOUS AIR BARRIER GRAPHIC REPRESENATION AT BUILDING ENVELOPE, SEE WALL SECTION FOR DETAIL, TYP BUILDING THERMAL ENVELOPE AIR LEAKAGE TEST 1. BUILDING AIR LEAKAGE TESTING SHALL BE PERFORMED PER ASTM C779 2. THE TARGET LEAKAGE RATE IS 0.25 CFM/FT2 (1.5 L/S*M2) AT 0.3 IN. WG (75 PA) 3. TESTED PORTIONS OF THE BUILDING SHALL INCLUDE ALL SPACES DIRECTLY UNDER THE ROOF, ALL SPACES THAT HAVE A BUILDING ENTRANCE, EXPOSED FLOOR, LOADING DOCK OR ARE BELOW GRADE PLANE, AND REPRESENTATIVE ABOVE- GRADE AREAS THAT TOTAL ≥25% OF THE BUILDING TOTAL ABOVE-GRADE WALL AREA; 4. THE WEIGHTED AVERAGE AIR LEAKAGE RATE OF THE BUILDING THERMAL ENVELOPE SHALL NOT EXCEED 0.25 CFM/FT2 (1.27 L/S*M2) WHEN MEASURED AT A PRESSURE DIFFERENTIAL OF 0.3 IN. WG (75 PA). 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:31:51 PM As indicated BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AIX723 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE BUILDING SECTIONS III CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1/4" = 1'-0" TRANVERSE SECTION - @ SECURITY ROOM A BT120-ARP221 SCALE: 1/4" = 1'-0" TRANVERSE SECTION - @ LACTATION ROOM B BT120-ARP221 SCALE: 1/4" = 1'-0" TRANVERSE SECTION - @ JANITOR ROOM C BT120-ARP221 SCALE IN FEET 2 44 80 4 RTA/CN 0205-24 CORE FACILITY 28' -2" 2.A 2.G CORE FACILITY-ROOF 41' -2" 2.D 2.E2.B 2.C TELECOM BT120L1208 E BT120-AED906 C BT120-AED909 FRAMING FOR CABLE SUPPORTS CORE FACILITY 28' -2" 2.A CORE FACILITY-ROOF 41' -2" 2.J 2.E2.C A BT120-AED906 C BT120-AED906 1 BT120-AID909 F BT120-AED908 ELECTRICAL BT120L1209 STORAGE 1 BT120L1210 D BT120-AED909 B BT120-AED906 FRAMING FOR CABLE SUPPORTS CONTINUOUS AIR BARRIER GRAPHIC REPRESENATION FOR BUILDING ENVELOPE, SEE WALL SECTION FOR DETAIL BUILDING THERMAL ENVELOPE AIR LEAKAGE TEST 1. BUILDING AIR LEAKAGE TESTING SHALL BE PERFORMED PER ASTM C779 2. THE TARGET LEAKAGE RATE IS 0.25 CFM/FT2 (1.5 L/S*M2) AT 0.3 IN. WG (75 PA) 3. TESTED PORTIONS OF THE BUILDING SHALL INCLUDE ALL SPACES DIRECTLY UNDER THE ROOF, ALL SPACES THAT HAVE A BUILDING ENTRANCE, EXPOSED FLOOR, LOADING DOCK OR ARE BELOW GRADE PLANE, AND REPRESENTATIVE ABOVE- GRADE AREAS THAT TOTAL ≥25% OF THE BUILDING TOTAL ABOVE-GRADE WALL AREA; 4. THE WEIGHTED AVERAGE AIR LEAKAGE RATE OF THE BUILDING THERMAL ENVELOPE SHALL NOT EXCEED 0.25 CFM/FT2 (1.27 L/S*M2) WHEN MEASURED AT A PRESSURE DIFFERENTIAL OF 0.3 IN. WG (75 PA). 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 1/20/2025 11:02:04 AM As indicated BT120 0 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AIX724 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE BUILDING SECTIONS IV CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1/4" = 1'-0" TRANVERSE SECTION - @ TELECOM ROOM A BT120-ARP221 SCALE: 1/4" = 1'-0" TRANVERSE SECTION - @ STORAGE/ ELECTRICAL B BT120-ARP221 SCALE IN FEET 2 44 80 4 RTA/CN 0205-24 CORE FACILITY 28' -2" CORE FACILITY-ROOF 41' -2" 2.B TYPICAL CMU WALL ASSEMBLY FROM OUTSIDE TO INSIDE TYPICAL ROOF ASSEMBLY FROM TOP TO BOTTOM TYPICAL INSULATION AT FOUNDATION PERIMETER. A BT120-AED909 6 1/2" METAL WALL PANEL PER ELEVATION A BT120-AED908 B BT120-AED909 TYP CMU VENEER WALL ASSEMBLY FROM OUTSIDE TO INSIDE -CMU VENEER, TYPE PER ELEVATIONS -2" AIR CAVITY -R10 CONTINUOUS INSULATION -AIR BARRIER -EXTERIOR SHEATHING -METAL 6" STUD FRAMING W/ R13 INSULATION, W/ VAPOR RETARDER -FINISH PER SCHEDULE PROVIDE UNDERSLAB VAPOR RETARDER, TYP. J BT120-AID900 1 CORE FACILITY 28' -2" CORE FACILITY-ROOF 41' -2" 2.D TYPICAL ROOF ASSEMBLY FROM TOP TO BOTTOM -METAL ROOFING -ROOF UNDERLAYMENT/ AIR BARRIER -PROTECTION BOARD -METAL DECKING OVER ROOF STRUCTURE -R-49 ATTIC INSULATION TYPICAL WALL ASSEMBLY FROM OUTSIDE TO INSIDE -METAL CLADDING -R10 CONTINUOUS INSULATION -AIR BARRIER -EXTERIOR SHEATHING -METAL STUD FRAMING W/ R13 INSULATION -FINISH PER SCHEDULE TYPICAL INSULATION AT FOUNDATION PERIMETER OUTSIDE TO INSIDE -PROTECTION BOARD W/ METAL SHEATHING AS NEEDED -CONTINUOUS W/ R-10 PERIMETER FOUNDATION INSULATION 24" BELOW THE GRADE -DAMPPROOFING F BT120-AED906 2'-0" D BT120-AED906 C BT120-AID900 D BT120-AID912 OPP E BT120-AED907 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:54 PM 3/4" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AIX725 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE WALL SECTIONS I CORE FACILITYJC DH CC JC DH CC 12/10/2024 452ISSUED FOR BID12/10/2024 SCALE: 3/4" = 1'-0"BT120-AIX722 WALL SECTION A SCALE: 3/4" = 1'-0"BT120-AIX722 WALL SECTION B SCALE IN FEET 012 2 1 06/13/2025 ADDENDUM #1 1 1 1 GENERAL NOTES: 1. SEE MECHANICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 2. SEE ELECTICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 3. SEE TELECOM DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 4. SEE ROOM FINISH SCHEDULE FOR MATERIALS AND FINISHES. 5. CONTRACTOR TO PROCURE AND PROVIDE FURNITURE AND APPLIANCE 6. FURNITURE: A. OFFICE CHAIR (OF-7) B. FILE CABINET (OF-6). C. SOFA/LOUNGE CHAIR (OF-8), D. END TABLE (OF-9), E. WASTE PAPER BASKET (OF-13), F. FOLDING BENCH WORK BENCH (OF-10) ELECTRICAL PANEL PLDC B BT120-AID912 OF-7, TYP. FILE CABINET, OF-6, TYP. 6' - 0"1' - 4"4' - 0"1' - 4" PLDC 2' - 6" PLDC SSCT 2'-6" 4' - 0"5' - 0"SEE A/ BT120-AID912 FOR 2' - 6" TA-4 TA-3 BASE CABINET FEC 2 BT120-AID902 SSCT 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 1/20/2025 11:02:07 AM BT120 0 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AIE821 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE INTERIOR ELEVATIONS CORE FACILITY - SECURITY ROOM 12/10/2024 J.C. D.H. C.C. 3/8" = 1' -0" ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE IN FEET 2 44 80 SCALE: 3/8" = 1'-0" BT120-APD222 SECURITY ELEVATION A A SCALE: 3/8" = 1'-0" BT120-APD222 SECURITY ELEVATION B B SCALE: 3/8" = 1'-0" BT120-APD222 SECURITY ELEV C1 C SCALE: 3/8" = 1'-0" BT120-APD222 SECURITY ELEV D1 D 4 RTA/CN 0205-24 GENERAL NOTES: 1. SEE MECHANICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 2. SEE ELECTICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 3. SEE TELECOM DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 4. SEE ROOM FINISH SCHEDULE FOR MATERIALS AND FINISHES. 5. CONTRACTOR TO PROCURE AND PROVIDE FURNITURE AND APPLIANCE 6. FURNITURE: A. OFFICE CHAIR (OF-7) B. FILE CABINET (OF-6). C. SOFA/LOUNGE CHAIR (OF-8), D. END TABLE (OF-9), E. WASTE PAPER BASKET (OF-13), F. FOLDING BENCH WORK BENCH (OF-10) A BT120-AID912 SSCT W/ BACKSPLASH REFRIGERATOR 3' - 0" 2' - 0" 1' - 10" 2' - 6" 3' W x 2' D SINK CABINET. SPLIT TOE KICK ATTACHED TO BACK OF EA. OPERABLE DOOR 4" RESILIENT BASE, TYP TA-4 TA-3 SINK OF-8, TYP OF-9 MOP SINK FAUCET WATER HEATER PT GWB, TYP 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 1/20/2025 11:02:09 AM BT120 0 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AIE822 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE INTERIOR ELEVATIONS CORE FACILITY - LACTATION ROOM, JANITOR ROOM 12/10/2024 J.C. D.H. C.C. 3/8" = 1' -0" ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE IN FEET 2 44 80 SCALE: 3/8" = 1'-0" BT120-APD223 LACTATION RM ELEV - D D SCALE: 3/8" = 1'-0" BT120-APD223 LACTATION RM ELEV - C C SCALE: 3/8" = 1'-0" BT120-APD223 LACTATION RM ELEV - B B SCALE: 3/8" = 1'-0" BT120-APD223 LACTATION RM ELEV - A A SCALE: 3/8" = 1'-0" BT120-APD223 JANITOR RM ELEV - A E SCALE: 3/8" = 1'-0" BT120-APD223 JANITOR RM ELEV - B F SCALE: 3/8" = 1'-0" BT120-APD223 JANITOR RM ELEV - C G SCALE: 3/8" = 1'-0" BT120-APD223 JANITOR RM ELEV - D H 4 4 RTA/CN 0205-24 GENERAL NOTES: 1. SEE MECHANICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 2. SEE ELECTICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 3. SEE TELECOM DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 4. SEE ROOM FINISH SCHEDULE FOR MATERIALS AND FINISHES. 5. CONTRACTOR TO PROCURE AND PROVIDE FURNITURE AND APPLIANCE 6. FURNITURE: A. OFFICE CHAIR (OF-7) B. FILE CABINET (OF-6). C. SOFA/LOUNGE CHAIR (OF-8), D. END TABLE (OF-9), E. WASTE PAPER BASKET (OF-13), F. FOLDING BENCH WORK BENCH (OF-10) CT PT GYP URINAL LAVATORY BEYOND TRANSLUCENT PANEL SYSTEM, TYP. 6'-4" PT GYP CT 3'-4" 1'-6" MIRROR TA-3 TA-12 TA-6 TYP 3'-0" TYP 6'-4" CT WAINSCOT PT GYP, TYP TA-1 TA-12 42" STAINLESS STEEL GRAB BAR TA-6 TA-5 3'-6" TYP TYP 6'-4" CT WAINSCOT PT GYP TRANSLUCENT PANEL SYSTEM, TYP. TA-3 TA-6 3'-0" PT GYP CT PT GYP CT PT GYP CT TA-1 TA-12 TA-5 TA-6 3'-6" PT GYP CT PT GWB, TYP. 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:32:12 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AIE823 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE INTERIOR ELEVATIONS CORE FACILITY - OPERATOR RESTROOM 12/10/2024 J.C. D.H. C.C. 3/8" = 1' -0" ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE IN FEET 2 44 80 SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 1 B SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 1 C SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 1 D SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 1 E SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 2 F SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 2 G SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 2 H SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 2 J SCALE: 3/8" = 1'-0" BT120-APD223 STORAGE A 4 RTA/CN 0205-24 GENERAL NOTES: 1. SEE MECHANICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 2. SEE ELECTICAL DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 3. SEE TELECOM DRAWING FOR LOCATION OF EQUIPMENT, FIXTURES. 4. SEE ROOM FINISH SCHEDULE FOR MATERIALS AND FINISHES. 5. CONTRACTOR TO PROCURE AND PROVIDE FURNITURE AND APPLIANCE 6. FURNITURE: A. OFFICE CHAIR (OF-7) B. FILE CABINET (OF-6). C. SOFA/LOUNGE CHAIR (OF-8), D. END TABLE (OF-9), E. WASTE PAPER BASKET (OF-13), F. FOLDING BENCH WORK BENCH (OF-10) TA-8 TRANSLUCENT PANEL SYSTEM, TYP.PT GYP CT TYP AT ALL OPERATOR RESTROOMS PT GYP CT TA-3 TA-6 TA-12 TYP 3'-0" PT GYP CT TA-6 TA-12 TA-1 TA-8 TA-5 TYP 3'-6" PT GYP CT TA-3 3'-0" TA-6 TYP 6'-4" CT WAINSCOTCT PT GYP TRANSLUCENT PANEL SYSTEM, TYP. PT GYP CT PT GYP CT TA-6 TA-1 TA-12TA-5 3'-6" PT GYP CT 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:32:16 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AIE824 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE INTERIOR ELEVATIONS CORE FACILITY - OPERATOR RESTROOM 12/10/2024 J.C. D.H. C.C. 3/8" = 1' -0" ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE IN FEET 2 44 80 SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 3 A SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 3 B SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 3 C SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 3 D SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 4 E SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 4 F SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 4 G SCALE: 3/8" = 1'-0" BT120-APD223 OPERATOR RESTROOM 4 H 4 RTA/CN 0205-24 D O PFIXFIXFI X FI X FI X FI X FIXFIXFIXPTZPTZFIXFIXCAM CAM CAM CA M CA M CA M CA M CA M CAM CAM CAM CAM WAP WAP WAP 2.A 2.G 2.72.32.1 2.J 2.E 2.112.102.92.82.62.52.4 2.B 2.F STORAGE 1 BT120L1210 ELECTRICAL BT120L1209 TELECOM BT120L1208 OPERATOR RESTROOM BT120L1207 OPERATOR RESTROOM BT120L1206 OPERATOR RESTROOM BT120L1205 OPERATOR RESTROOM BT120L1204 JANITOR BT120L1203 LACTATION ROOM BT120L1202 SECURITY BLDG BT120L1200 ROOF OVERHANG WINDOW OVERHANG, TYP. A.F.F. GYP BD 8' - 0" A.F.F. ACT 24" X 24" 8' - 0" A.F.F. ACT 24" X 24" 8' - 6" B BT120-AIX724 A BT120-AIX722 A BT120-AIX723A BT120-AIX724 C BT120-AIX723 B BT120-AIX723 A BT120-AIX721 2.C 1 BT120-ACP222 1 BT120-ACP223 SEC STORAGE BT120L1201 EXPOSED TO ROOF EXPOSED TO ROOF 2.2 A.F.F. ACT 24" X 24" 8' - 6" OTSOTSOTS OTS 8'-7 3/8"7'-0 1/2"8'-0 7/8" A BT120-AED906 D BT120-AED907 11'-5" 2.H C BT120-AED908 C BT120-AID909 A.F.F. GYP BD 10' - 0"A.F.F. GYP BD 10' - 0" A.F.F. GYP BD 8' - 0"A.F.F. GYP BD 8' - 0" A.F.F. GYP BD 10' - 0" A.F.F. GYP BD 8' - 0" A.F.F. GYP BD 10' - 0" CEILING FRAMINGS FOR MOUNTING CABLE TRAY MOUNTING 14'-9 3/4" 14'-8 7/8"12'-4 7/8" 3'-1 1/8" 5'-0" 3'-0" 2 BT120-AED909 3 BT120-AED909 LIGHT FIXTURE LIGHT FIXTURE LEGEND EXHAUST FAN CAMERA DOWNSPOUT 24" x 24" ACT METAL SOFFIT GYP BD 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:55 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ACP221 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE OVERALL REFLECTED CEILING PLAN CORE FACILITYJC DH CC JC DH CC 3/16" = 1' -0" 12/10/2024 457ISSUED FOR BID12/10/2024 SCALE IN FEET 2 44 80 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 11 CEILING NOTE: PROVIDE CEILING 2'X2' WHITE METAL ACCESS PANEL @ GYP CEILINGS, PANELS TO BE FIELD LOCATED ADJACENT TO CENTER OF THE LOWER CEILING AT OPERATOR RESTROOMS, TYP 1 1 D OFIXPTZPTZCAM CAM CAM WAP LIGHT FIXTURE LIGHT FIXTURE LEGEND EXHAUST FAN CAMERA DOWNSPOUT 24" x 24" ACT METAL SOFFIT GYP BD 2.A 2.G 2.D 2.E 2.112.102.9 2.B 2.F A BT120-AIX723 A BT120-AIX721 2.C A.F.F.TYP. ACT 24" X 24" 8' - 6" 2 BT120-ACP222 2.A 2.D 2.E 2.102.9 2.B A BT120-AIX723 2.C C BT120-AED907 METAL SOFFIT METAL FASCIA SLOPE SLOPE SLOPE DOWNSPOUT F BT120-AED906 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:56 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ACP222 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE REFLECTED CEILING PLAN CORE FACILITY - SECURITY ROOM JC DH CC JC DH CC 3/8" = 1' -0" 12/10/2024 458ISSUED FOR BID12/10/2024 SCALE IN FEET 024 4 SCALE: 3/8" = 1'-0" REFLECTED CEILING PLAN - @ SECURITY A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 SCALE: 3/8" = 1'-0" REFLECTED CEILING PLAN - @ ABOVE SECURITY ROOF 1 1 1 FIXFI X FI XFIXCA M CA M CA M WAP LIGHT FIXTURE LIGHT FIXTURE LEGEND EXHAUST FAN CAMERA DOWNSPOUT 24" x 24" ACT METAL SOFFIT GYP BD 2.A 2.7 2.D 2.E 2.82.62.5 2.B 2.C CL 2'-6 7/8" CL CL CL CL CL CL CL EQEQ EQEQ EQA.F.F.TYP. GYP BD 10' - 0" A.F.F.TYP. GYP BD 8' - 0" A.F.F.TYP. ACT 24" X 24" 8' - 6" MECHANICAL UNITS, TYP K BT120-AID900 TYP 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:57 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ACP223 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE REFLECTED CEILING PLAN CORE FACILITY - PUBLIC FACILITY JC DH CC JC DH CC 3/8" = 1' -0" 12/10/2024 459ISSUED FOR BID12/10/2024 SCALE IN FEET 024 4 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 1 1 2.8 2.C FENCE WITH TRANSLUCENT PANELS ABOVE CMU VENEER 2.9 2.C TRANSLUCENT WINDOW PANELS TYPE I CMU VENEER, TYP. WINDOW AS SCHEDULED WEATHER BARRIER HSS COLUMN HSS 6 X 4 X 5/16 ALUMINUM FRAME INTERMEDIATE MULLION AS NEEDED 2" 1.5" MIN AIR CAVITY HSS 6X4X5/16 PER STRUCTURAL 2.10 2.B 2.C DOWNSPOUT, GUTTER ABOVE GYP BOARD CMU VENEER, TYP. WINDOW AS SCHEDULED DOOR AS SCHEDULED 4"DOWNSPOUT OUTLET BELOW GROUND PLYWOOD SHEATHING RIGID INSULATION WEATHER BARRIER CONT. FORMED METAL WI N D O W INSULATION CORE FACILITY 28' -2" SECURITY 27.530 2.11 CMU VENEER MASONRY FLASHING 5/8" GYP BOARD R13 INSULATION 5/8" PLYWOOD SHEATHING R10 RIGID INSULATION 1.5" MIN AIR CAVITY 2 x 6 MTL STUD FRAMING @ 24 OCCONTINUOUS SEALANT JOINT WEEP @ 16" O.C. FINISH GRADE WATERPROOFING MEMBRANE CMU VENEER TIE, TYP. FLOOR SLAB/ FOUNDATION SLOPE 11 1/2" EDGE OF SLAB 2.1 2.E 2.2 0.08 IN BRAKE SHAPE ALUMINUM, PREFINISHED 8" 6" TYP. WALL ASSEMBLY 2.3 2.J 4" DIA DOWNSPOUT GUTTER, ABOVE CMU VENEER, TYP. SHEATHING RIGID INSULATION AIR BARRIER 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:32:27 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED905 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE MISC DETAILS CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3" = 1'-0" BT120-APD222 TRANSLUCENT WALL AND FENCE AT STORAGE CMU DETAIL 3 SCALE: 3" = 1'-0" BT120-APD222 TRANSLUCENT WALL AND FENCE AT SECURITY BLDG CMU DETAIL 2 SCALE: 3" = 1'-0" BT120-APD222 DOWNSPOUT INSET @ CMU WALL DETAIL 1 SCALE: 1 1/2" = 1'-0" BT120-AIX721 EXTERIOR WALL BASE DETAIL, TYP.A SCALE: 1 1/2" = 1'-0" BT120-APD224 BRAKE METAL @ WALL TRANSITION 5 SCALE: 1 1/2" = 1'-0" BT120-APD225 EXTERIOR WALL PLAN @ STORAGE BELOW ROOF 4 4 RTA/CN 0205-24 2.J ROOF ASSEMBLY 6" PREFINISHED METAL COPING 2X WOOD BLOCKING AS NEEDED CONT. ROOF AIR BARRIER METAL ROOF STRUCTURAL ROOF DECK TYPICAL WALL ASSEMBLY CORE FACILITY-ROOF 41' -2" 2.E STANDING SEAM METAL ROOF STEEL FASCIA, C-2, TYP. SOFFIT PANELS STRUCTURAL STEEL FRAMING F BT120-AED906 FLASHING COUNTER FLASHING CONT. SEALANT STANDING SEAM METAL ROOF PLYWOOD SHEATHING METAL DECKING CMU VENEER WOOD BLOCKING Z CLOSURE ANGLE RIGID INSULATION BUTYL SEALANT 1 1/2" MIN AIR CAVITY 2.3 GUTTER STANDING SEAM METAL ROOF SYSTEM CMU VENEER 1 1/2" MIN AIR CAVITY R10 RIGID INSULATION R13 INSULATION 1/2" SHEATHING FINISH PER SCHEDULE 1 1/2" METAL DECK ROOFING UNDERLAYMENT OVER 1/2" PLYWOOD SHEATHING BENT PLATE FLASHING VAPOR BARRIER METAL FLASHING STRUCTURAL MEMBER 1/2" / 12" AIR BARRIER 7" STEEL FASCIA, C-2, TYP. METAL STANDING SEAM ROOF NEOPRENE SHIM / DISSIMILAR METAL PROTECTION, TYP SOFFIT PANEL & FRAMING ABOVE METAL DECK INSULATION 1/2" PLYWOOD SHEATHING DRIP EDGE 1/4" NEOPRENE SHIM STRUCTURAL STEEL FRAMING STEEL ATTACHMENT ANGLE MISC STEEL FRAMING FOR FASCIA BACKING AND ATTACHMENT, TYP 3" ROOF CLOSER ANGLE FOR FASCIA ATTACHMENT, MATCH FASCIA FINISH, TYP 2.A CORE FACILITY-ROOF 41' -2" GUTTER STEEL FASCIA, C-2, TYP. WOOD BLOCKING BRAKE SHAPE METAL STANDING SEAM METAL ROOF 1/2" / 12" METAL FLASHING ROOF UNDERLAYMENT OVER 1/2" PLYWOOD SHEATHING METAL ANGLE BRAKE SHAPE METAL STRUCTURAL STEEL FRAMING DOWNSPOUT TYPICAL WALL ASSEMBLY STRUCTURAL ROOF DECK METAL SOFFIT METAL FLASHING 11 1/2" 2" RIGID INSULATION, TYP 2.D HSS 6x4x5/16 PER STRUCTURAL DOOR AS SCHEDULED SEALANT WEATHER RESISTIVE BARRIER AND AIR BARRIER SLOPE: 1/4" PER 1'-0" TRANSLUCENT PANEL SYSTEM METAL FLASHING . 1/2" METAL PLATE, PER STRUCTURAL 1/2" THICK x 4.5" HEIGHT METAL BLADE WELDED TO BEAM 12" 4 1/2" C-5 AT AWNING SOFFIT, TYP. STEEL AWNING, C-2, TYP 1 1/2" 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:32:30 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED906 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR DETAILS CORE FACILITY12/10/2024 J.C. D.H. C.C. 1 1/2" = 1' -0" ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1 1/2" = 1'-0" BT120-ARP321 ROOF COPING DETAIL C SCALE: 1 1/2" = 1'-0" BT120-AIX724 WALL SECTION @ UPPER / LOWER ROOF DETAIL B SCALE: 3" = 1'-0" BT120-ARP321 GUTTER DETAIL @ SECURITY/STORAGE ROOM A SCALE: 3" = 1'-0" BT120-AIX725 ROOF DETAIL @ FASCIA, TYP.F SCALE: 1 1/2" = 1'-0" BT120-AIX723 ROOF DETAIL @ GUTTER E SCALE: 3" = 1'-0" OVERHANG DETAIL @ CLERESTORY D BT120-APP221 4 RTA/CN 0205-24 CORE FACILITY-ROOF 41' -2" STANDING SEAM METAL ROOF STEEL FASCIA, C-2, TYP. METAL ANGLE METAL SOFFIT PANEL HSS STRUCTURAL FRAMING METAL CRICKET FLASHING SEALANT METAL PLATE METAL DECK PLYWOOD SHEATHING WEATHER BARRIER, TYP. RIGID INSULATION WF STRUCTURAL FRAMING SECURITY-ROOF 39.530 2.F TYPICAL WALL ASSEMBLY PREFINISHED METAL COPING W18X50 STRUCTURAL FRAMING WOOD BLOCKING CONT. ROOF AIR BARRIER STANDING SEAM METAL ROOFING BEYOND STRUCTURAL ROOF DECK 2.11 METAL ROOF SYSTEM METAL ROOF FASCIA TRIM METAL FLASHING AIR BARRIER WOOD BLOCKING CMU VENEER STRUCTURAL DECKING INSULATION TYPICAL WALL ASSEMBLY CORE FACILITY-ROOF 41' -2" 2.8 3" STEEL GRATING SCREEN, C-1, TYP SOFFIT DOWNSPOUT 2.D INSULATION, TYP SHEATHING PAINTED STEEL ANGLE FLASHING METAL SOFFIT PANEL 1-1/2" VERTICAL RAINSCREEN GIRTS TO ALIGN W/ CAVITY WALL AIR SPACE BELOW FORMED METAL WALL PANEL AIR BARRIER FRAMING FOR SOFFIT ATTACHMENT AS NEEDED 1-1/2" HORIZONTAL HANGAR RAIL @ 24" OC STANDOFF CLIPS RAIN CLADDING SYS 2.D 1-1/2" VERTICAL RAINSCREEN GIRTS TO ALIGN W/ CAVITY WALL AIR SPACE BELOW 1-1/2" HORIZONTAL HANGAR RAIL @ 24" OC STANDOFF CLIPS 4" TYPICAL CMU VENEER WALL ASSEMBLY LEDGER ANGLE, PT C-2 METAL FLASHING, MATCH FORMED METAL WALL PANEL FINISH. SHEATHING AIR BARRIER FORMED METAL WALL PANEL 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:32:33 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED907 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE MISC DETAILS CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3" = 1'-0" BT120-ARP321 EDGE DETAIL @ MAIN ROOF C SCALE: 3" = 1'-0" BT120-AIX723 ROOF EDGE DETAIL @ SECURITY BLDG _ GL 2.F A SCALE: 3" = 1'-0" BT120-AIX721 ROOF EDGE DETAIL @ SECURITY BLDG B SCALE: 1" = 1'-0" PARTIAL ROOF PLAN @ MECH OPENING D BT120-ARP221 SCALE: 3" = 1'-0" BT120-AIX725 WALL PANEL TO SOFFIT TRANSITION E SCALE: 3" = 1'-0" WALL PANEL TO SOFFIT TRANSITION F - 4 RTA/CN 0205-24 CORE FACILITY-ROOF 41' -2" 2.E STEEL FASCIA, C-2, TYP. HSS 6X4X1/4 STRUCTURAL FRAMING METAL SOFFIT TYP. WALL ASSEMBLY TYP. ROOF ASSEMBLY STRUCTURAL DECKING 2X WOOD BLOCKING 2" RIGID INSULATION STRUCTURAL DECKING VAPOR RETARDER VAPOR BARRIER ROOF UNDERLAYMENT PLYWOOD SHEATHING ROOF ASSEMBLY TYPE 1A SEE DETAIL NOTES. R49 BATT INSULATION BOT OF STRUCTURAL MEMBERS WHERE OCCURS PROVIDE WIRE SUPPORT SYSTEM AND C CHANNEL FRAMING 24" OC AS REQUIRED METAL ROOF ROOF UNDERLAYMENT STRUCTURAL ROOF DECK AIR BARRIER GYPSUM COVERBOARD R38 INSULATION PYLWOOD SHEATHING METAL SCREEN METAL ANGLE HSS 4X4X1/4 STRUCTURAL FRAMING EXTERIOR WALL STEEL PLATE CONT. CLOSURE PLATE METAL ANGLE HSS 6X4X1/4 STRUCTURAL FRAMING 1/4" NEOPRENE SHIM, TYP. CONT. SEALANT CONT. SEALANT STEEL FASCIA, C-2, TYP. METAL SCREEN GUSSET KNIFE PLATE HSS HANGER 2.2METAL ROOF SYSTEM METAL COPING UNDERLAYMENT CMU VENEER TYPICAL WALL ASSEMBLY PLYWOOD SHEATHING 2X4 WD BLOCKING STRUCTURAL DECKING R-38 INSULATION FOAM FILL INSULATION AT DECK FLUTE 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:32:36 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED908 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE MISC DETAILS CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1 1/2" = 1'-0" BT120-AIX723 MAIN ROOF AT SECURITY BLDG ROOF DETAIL D SCALE: 3" = 1'-0" BT120-AIX721 ROOF ASSEMBLY TYPE 1_DOC E SCALE: 3" = 1'-0" BT120-AIX724 ROOF ASSEMBLY TYPE 2_DOC F DETAIL NOTES: TYPE 1A IS SIMILAR ASSEMBLY WITHOUT R49 INSULATION. IT OCCURS AT CANOPY ABOVE OPEN AREA BETWEEN SECURITY OFFICE AND SECURITY STORAGE. SCALE: 3" = 1'-0" BT120-AIX723 DETAIL @ METAL SCREEN MECH EQMT LOWER B SCALE: 3" = 1'-0" BT120-AIX725 DETAIL @ METAL SCREEN MECH EQMT UPPER A SCALE: 3" = 1'-0" BT120-ARP321 ROOF DETAIL @ STORAGE C 4 RTA/CN 0205-24 CORE FACILITY 28' -2" 2.A 2.B LANDSCAPE PLANTER EDGE SIDEWALK VEGITATIVE SCREEN SUPPORT BRACKETS, TYP. METAL SUPPORT STRUCTURE 4 1/2" CORE FACILITY SIDE CMU VENEER 2" AIR SPACE RIGID INSULATION PLYWOOD SHEATHING INSULATION GYP BOARD DAMPPROOFING MEMBRANE PERFORATED PERIMETER DRAIN SEALANT 0' - 6" TOP OF LANDSCAPE GRADING SHEET METAL OVER PROTECTION BOARD 2.B 7" INSULATION METAL FLASHING STANDING SEAM ROOFING CMU VENEER 2x BLOCKING 2.9 2.C EXTERIOR WALL ASSEMBLY WINDOW ASSEMBLY BRICK VENEER RIGID INSULATION 1" INSULATION GYP BOARD AIR BARRIER PLYWOOD SHEATHING 8' H PICKET RAILING, COLOR: C1, TYP. METAL RAIL FRAMING BACKER ROD AND SEALANT 2.F RIGID INSULATION SEALANT WINDOW FRAME 4" CMU VENEER 5/8" GWB STEEL ANGLE 4 1/2" SLOPE: 1/4" PER 1'-0" . CORE FACILITY 28' -2" 2.A CONCRETE FOOTING R10 INSULATION VAPOR RETARD MEMBRANE AIR BARRIER INSULATION CMU VENEER 2.E AIR BARRIER INSULATION REGLET FLASHING METAL ANGLE CMU VENEER METAL STUD WALL PLUMBING CHASE WALL TRANSPARENT PANEL SYSTEM SEALANT ON BOTH SIDES METAL STUD 5/8" GWB FACE OF INTERIOR WALL FACE OF EXTERIOR WALL 2.D 2.6 STRUCTURAL COLUMN FACE OF INTERIOR WALL TRANLUCENT PANEL SYSTEM JOINT SEALANT GYPSUM WALLBOARD 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:32:40 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED909 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE PLANTER BOX DETAIL, MISC CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1 1/2" = 1'-0" BT120-AIX725 PLANTER BOX DETAIL A SCALE: 1 1/2" = 1'-0" BT120-AIX725 GUTTER AT EQUIPMENT CAGE B BT120-APP221 SCALE: 1 1/2" = 1'-0" BT120-AES911 DETAIL @ PICKET FENCE AND WALL 1 SCALE: 3" = 1'-0" BT120-AIX723 OVERHANG DETAIL @ SECURITY E BT120-ARP221 SCALE: 1" = 1'-0" BT120-AIX724 TYPICAL INSULATION AT FOUNDATION C SCALE: 1" = 1'-0" BT120-AIX724 WALL DETAIL @ GRIDLINE 2.E D BT120-ARP221 SCALE: 1 1/2" = 1'-0" BT120-ACP221 WALL DETAIL AT TRANSLUCENT PANEL 2 SCALE: 3" = 1'-0" BT120-ACP221 TRANSLUCENT PANEL PLAN DETAIL 3 BT120-ACP251 4 4 RTA/CN 0205-24 2'-0" 4" PARTITION TYPE LEGEND PARTITION TYPEX 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:32:48 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AES910 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE PARTITION TYPES CORE FACILITY12/10/2024 J.C. D.H. C.C. NTS ISSUED FOR BID12/10/2024 ISSUED FOR BID (TYPE B) TYPICAL PARTITION1 MARK STUD WIDTH PRTN WIDTH Design STC B 6"6 5/8"50 (TYPE A1) TYPICAL PARTITION @ CONC CURB MARK STUD WIDTH PRTN WIDTH Design STC A1 6"7 1/4"50 (TYPE A) TYPICAL PARTITION MARK STUD WIDTH PRTN WIDTH Design STC A 6"7 1/4"50 1. PARTITIONS ARE DISTINGUISHED ON FLOOR PLANS BY SYMBOL DESIGNATION, GRAPHIC DESIGNATION OR A COMBINATION OF BOTH DESIGNATIONS. SOME PARTITION TYPES SHOWN ON THIS SHEET MAY NOT BE USED ON THIS PROJECT. 2. ALL WALLS NOT DESIGNATED WITH A GRAPHIC OR TAG TO BE TYPE A1. IF UNCLEAR CONTACT ARCHITECT. 3. SOUND TRANSMISSION CLASS (STC) IS A RATING SYSTEM THAT DESCRIBES THE ABILITY OF AN ASSEMBLY TO REDUCE THE TRANSMISSION OF SOUND. CONFIGURE SOUND-RATED WALL ASSEMBLIES ACCORDING TO THE MINIMUM REQUIREMENTS STIPULATED IN THE STC TESTS LISTED. STC RATINGS LISTED ARE BASED ON LABORATORY TESTING AND ARE NOT INDICATIVE OF RESULTS IN FIELD. 4. REFER TO SECTION 09 29 00 FOR ACOUSTIC SEALANTS. 5. SOUND ATTENUATION BATTS (SAB) ARE SPECIFIED IN SECTION 09 29 00. WHERE SAB ARE INDICATED, THEY SHALL EXTEND CONTINUOUSLY FROM FLOOR TO STRUCTURE ABOVE. 6. PARTITIONS ARE INDICATED WITH CONVENTIONAL GYPSUM WALLBOARD U.N.O.; UPGRADE TO PREMIUM TYPES OF WALLBOARD (I.E., MOISTURE-RESISTANT, TILE-BACKER BOARD, ACOUSTICALLY ENHANCED, ETC.) BASED ON THEIR LOCATION AND ACCORDING TO REQUIREMENTS OF SECTION 09 29 00. 7. "LINE OF STRUCTURE" INDICATED FOR EACH PARTITION IS DIAGRAMATIC ONLY AND DOES NOT INDICATE EXACT CONSTRUCTION CONDITIONS OR GEOMETRY. 8. ALL DIMENSIONS ARE FROM FACE TO FACE, OR CENTERLINE TO CENTERLINE, U.N.O. REFER TO PARTITION MATRICES FOR PARTITION WIDTH DIMENSIONS UNLESS INDICATED TO BE SHOWN ON PLAN. 9. REFER TO THE TOILET ACCESSORIES SHEET AND CASEWORK SHEET FOR MOUNTING DETAIL INFORMATION. GENERAL PARTITION NOTES: 4 RTA/CN 0205-24 2.9 2.8 HSS 6 X 4 W16 X 45 9'-7 1/2"9'-7 1/2" 11'-6" 8'-0" 20'-3 3/4" 3'-6" TRANSLUCENT WINDOW TYPE I METAL VERTICAL BLADE FENCE C BT120-AES911 4" E BT120-AES911 F BT120-AES911 CORE FACILITY 28' -2" CORE FACILITY-ROOF 41' -2" 2.72.62.5 8'-0" TRANSLUCENT PANEL SYSTEM, TYP. D BT120-AES911 METAL CANOPY ACCENT CMU, TYP. FORMED METAL WALL PANEL A BT120-AID909 17' - 4"17' - 3" D BT120-AID909 2.7 2.D 2.E 2.62.5 METAL CANOPY BELOW EXTERIOR WALL ASSEMBLY, TYP. TRANSLUCENT PANEL SYSTEM, TYP. 1 BT120-AES911 METAL CANOPY SUPPORTS, TYP. D BT120-AID909 2.5 R13 INSULATION BRICK VENEER RIGID INSULATION PLYWOOD SHEATHING GYP BOARD AIR BARRIER 2.9 2.8 2.C F BT120-AES911 F BT120-AID900 TRANSLUCENT PANEL SYSTEMCMU VENEER 2.9 2.8 2.C 1 BT120-AED909 C1: 8' H STEEL PICKET RAILINGCMU VENEER W2 3 1/2" 1/2" 3" * NOTE: ARRANGE VERTICAL RAILING MEMBER SO THAT THE ARRANGMENT WOULD HAVE EQUAL SPACING AT BOTH VERTICLE POSTS SEE NOTE CORE FACILITY 28' -2" 2.A CORE FACILITY-ROOF 41' -2" 2.D2.E 2.B2.C C BT120-AES911 E BT120-AES911 F BT120-AID900 B BT120-AID909 MIN 6"H STEEL FRAMINGS @ 24" OC MAX FOR SOFFIT ATTACHMENT STEEL FRAMING TO CONNECT TO ROOF BEAM WITH VERTICAL STEEL STUDS, TYP. REFER TO STRUCTURAL ROOF FRAMING PLAN 3/4" THICK BASE PLATE ON TOP OF CONCRETE SIDEWALK, APPLY GROUT TO LEVEL BASE PLATE AS NEEDED. CONNECT VERTICAL BLADE PICKETS TO TOP AND BOTTOM STEEL PLATES WITH DOUBLE SIDED FILLET WELDS, TYP 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:32:54 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AES911 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE TRANSLUCENT WINDOW TYPES CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3/8" = 1'-0" BT120-APP221 TRANSLUCENT PANEL - ENLARGED ELEVATION A SCALE: 3/8" = 1'-0" BT120-APD223 TRANSLUCENT PANEL - ENLARGED ELEVATION B SCALE: 3/8" = 1'-0" ENLARGED PLAN @ TRANSLUCENT TYPE II D - SCALE: 1 1/2" = 1'-0" BT120-AES911 JAMB DETAIL @ TRANSLUCENT WINDOW TYPE II 1 SCALE: 3/8" = 1'-0" SECTION @ TRANSLUCENT PANEL C - SCALE: 1" = 1'-0" BT120-APD222 SECTION @ PICKET FENCE E SCALE: 3/8" = 1'-0" SECTION @ TRANSLUCENT WINDOW & FENCE F - 4 RTA/CN 0205-24 CT CERAMIC TILE GWB GYPSUM WALL BOARD CB CEMENT WALL BOARD PT PAINTED CMU CONCRETE MASONRY UNIT RB RUBBER BASE GWB GYPSUM WALL BOARD SC SEALED CONCRETE PT-3 PORCELAIN TILE ROOM FINISH LEGEND A B C HEIGHT WIDTH WIDTH WIDTH HEIGHT HEIGHT VISION PANEL FLUSH SECTIONAL FF INSULATED SECTIONAL DOOR HM HOLLOW METAL MTL METAL PT PAINTED DOOR FINISH LEGEND F1 F2 W1 SILL HEIGHT HEIGHT WIDTH SILL HEIGHT HEIGHT W2 W3 WIDTH W4 SILL HEIGHT HEIGHT WIDTH W5.1/ W5.2/ W5.3/ W8 1' - 4" WIDTH W6 SILL HEIGHT 0' - 8" HEIGHT WIDTHTRANSLUCENT PANEL METAL FENCE C2-1, TYP. METAL BRAKE PANEL W7 NOTE: REFER TO SHEET AES911 FOR ADDTIONAL INFORMATION FOR W4 AND W7. HEIGHT V.I.F. 8' - 0" V.I.F. 3' - 6" V.I.F. WIDTH SILL HEIGHT V.I.F. HEIGHT V.I.F. WIDTH 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:32:57 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AES912 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE SCHEDULES CORE FACILITY12/10/2024 J.C. D.H. C.C. NTS ISSUED FOR BID12/10/2024 ISSUED FOR BID ROOM FINISH SCHEDULE ROOM NUMBER ROOM NAME FLOOR WALLS CEILIN G *REMARKSFLOOR BASE NORTH EAST SOUTH WEST FINISH BT120L1200 SECURITY BLDG SC RB GWB/PT GWB/PT GWB/PT GWB/PT ACT ABUSE RESISTANT WALL COVERING BT120L1201 SEC STORAGE SC RB GWB/PT GWB/PT GWB/PT GWB/PT PT PAINTED STRUCTURE, ABUSE RESISTANT WALL COVERING BT120L1202 LACTATION ROOM PT-3 RB GWB/PT GWB/PT GWB/PT GWB/PT ACT BT120L1203 JANITOR SC RB GWB/PT GWB/PT GWB/PT GWB/PT PT BT120L1204 OPERATOR RESTROOM PT-3 RB CT/CB/PT GWB/PT CT/CB/PT CT/CB/PT GWB/PT SEE CEILING PLAN BT120L1205 OPERATOR RESTROOM PT-3 RB CT/CB/PT CT/CB/PT CT/CB/PT GWB/PT GWB/PT SEE CEILING PLAN BT120L1206 OPERATOR RESTROOM PT-3 RB CT/CB/PT GWB/PT CT/CB/PT CT/CB/PT GWB/PT SEE CEILING PLAN BT120L1207 OPERATOR RESTROOM PT-3 RB CT/CB/PT CT/CB/PT CT/CB/PT GWB/PT GWB/PT SEE CEILING PLAN BT120L1208 TELECOM SC RB GWB/PT GWB/PT GWB/PT GWB/PT PT PAINTED STRUCTURE BT120L1209 ELECTRICAL SC RB GWB/PT GWB/PT GWB/PT GWB/PT PT PAINTED STRUCTURE BT120L1210 STORAGE 1 SC RB GWB/PT GWB/PT GWB/PT GWB/PT PT PAINTED STRUCTURE DOOR AND FRAME SCHEDULE ROOM NUMBER ROOM NAME DOOR NO.TY P E DOOR FRAME HA R D W A R E NOTES & REMARKS SIZE RATIN G MA T E R I A L FI N I S H TY P E MA T E R I A L FI N I S H DETAILS WI D T H HE I G H T FI R E M I N SO U N D S T C HEAD JAMB SILL BT120L1200 SECURITY BLDG BT120L1200A A 3' - 0" 7' - 0"HM PT F1 HM PT A/AID900 1/AID900 D/AID900 HW-1 INSULATED BT120L1200 SECURITY BLDG BT120L1200B A 3' - 0" 7' - 0"HM PT F1 HM PT A/AID900 1/AID900 D/AID900 HW-1 INSULATED BT120L1201 SEC STORAGE BT120L1201 B 3' - 0" 7' - 0" - - HM PT F1 HM PT A/AID900 1/AID900 D/AID900 HW-1 PROVIDE PUSH PLATES, INSULATED BT120L1202 LACTATION ROOM BT120L1202 B 3' - 0" 7' - 0" - - HM PT F1 HM PT A/AID900 1/AID900 D/AID900 HW-3 INSULATED BT120L1203 JANITOR BT120L1203 B 3' - 0" 7' - 0" - - HM PT F1 HM PT A/AID900 1/AID900 D/AID900 HW-1 INSULATED BT120L1204 OPERATOR RESTROOM BT120L1204 B 3' - 0" 7' - 0" - - HM PT F1 HM PT A/AID900 1/AID900 D/AID900 HW-3 INSULATED BT120L1205 OPERATOR RESTROOM BT120L1205 B 3' - 0" 7' - 0" - - HM PT F1 HM PT A/AID900 1/AID900 D/AID900 HW-3 INSULATED BT120L1206 OPERATOR RESTROOM BT120L1206 B 3' - 0" 7' - 0" - - HM PT F1 HM PT A/AID900 1/AID900 D/AID900 HW-3 INSULATED BT120L1207 OPERATOR RESTROOM BT120L1207 B 3' - 0" 7' - 0"HM PT F1 HM PT A/AID900 1/AID900 D/AID900 HW-3 INSULATED BT120L1208 TELECOM BT120L1208A B 6' - 0" 8' - 4"HM PT F2 HM PT A/AID900 1/AID900 D/AID900 HW-2 INSULATED BT120L1208 TELECOM BT120L1208B B 3' - 0" 8' - 4"HM PT F1 HM PT A/AID900 1/AID900 D/AID900 HW-1 INSULATED BT120L1209 ELECTRICAL BT120L1209 B 4' - 0" 8' - 4" - - HM PT F1 HM PT A/AID900 1/AID900 D/AID900 HW-1 INSULATED BT120L1210 STORAGE 1 BT120L1210A B 3' - 0" 7' - 8" - - HM PT F1 HM PT A/AID900 1/AID900 D/AID900 HW-1 INSULATED BT120L1210 STORAGE 1 BT120L1210B C 8' - 8" 8' - 0" - - MTL PT G/S PT OH INSULATED SECTIONAL DOOR DOOR TYPES FRAME TYPES WINDOW SCHEDULE TYPE COUNT WIDTH HEIGH T SILL HEIGHT HEAD DETAIL JAMB DETAIL SILL DETAIL COMMENTS W1 2 4' - 9 1/2" 4' - 0" 3' - 4" B/AID900 2/AID900 E/AID900 SECURITY GLAZING W2 1 2' - 8" 4' - 0" 3' - 4" B/AID900 2/AID900 E/AID900 SECURITY GLAZING W3 1 2' - 0" 4' - 0" 3' - 4" B/AID900 2/AID900 E/AID900 SECURITY GLAZING W4 1 19' - 3" 3' - 6" 0' - 0" B/AID909 2/AED905 F/AID900 TRANSLUCENT TYPE I W5.1 4 1' - 4" 8' - 8" 0' - 0" C/AID909 1/AID909 D/AID909 TRANSLUCENT W5.2 3 4' - 1 1/2" 4' - 0" 3' - 4" B/AID900 2/AID900 E/AID900 SECURITY GLAZING W5.3 1 3' - 5 1/2" 4' - 0" 3' - 4" B/AID900 2/AID900 E/AID900 SECURITY GLAZING W6 1 9' - 4" 2' - 8" 8' - 0" A/AID909 1/AID909 D/AID909 SIM TRANSLUCENT W7 1 32' - 8" 2' - 0" 8' - 0" A/AID909 1/AID909 D/AED906 TRANSLUCENT W8 8 1' - 4" 10' - 0" 0' - 0" C/AID909 1/AID909 D/AID909 SPANDREL WINDOW TYPES 1 EA PANIC DEVICE 1 EA VISUAL INDICATOR 1 EA MORTISE LOCKSET 1 EA KICKPLATE 1 EA SWEEP 1 EA THRESHOLD 1 EA WEATHERSTRIPPING 1 EA CLOSER W/STOP-PUSH SIDE MOUNTED HW-3 1 PR BUTTS 2 EA KICKPLATES 1 EA ASTRAGAL 1 EA SWEEP 1 EA PANIC DEVICE 1 EA ELECTRIFIED LOCKSET (ACTIVE LEAF) 1 EA THRESHOLD 1 EA WEATHERSTRIPPING 1 EA OVERHEAD STOP - HOLD OPEN 1 EA SURFACE BOLTS - TOP AND BOTTOM 2 EA PULL HANDLES 1 EA ELECTRIFIED HINGE (ACTIVE LEAF) HW-2 3 PR BUTT HINGES 1 EA PANIC DEVICE 1 EA ELECTRIFIED LOCKSET 1 EA KICKPLATE 1 EA SWEEP 1 EA THRESHOLD 1 EA WEATHERSTRIPPING 1 EA CLOSER W/STOP-PUSH SIDE MOUNTED 1 EA ELECTRIFIED HINGE HW-1 1 PR BUTT HINGES HW SET QTY UNIT DESCRIPTION HARDWARE SCHEDULE DOOR SCHEDULE NOTES: ALL EXTERIOR DOORS ARE INSULATED WITH U=0.37 MAX WINDOW SCHEDULE NOTES TRANSLUCENT PANEL SYSTEM AND WINDOWS ASSEMBLY: U= 0.26 MAX, SHGC = 0.38MAX, VT=1.1 X SHGC, PROJECTION FACTOR (SECURITY OFFICE) = 0.75 MIN PROJECTION FACTOR = 0.88 (E WALL) & SPANDREL TRANSLUCENT PANELS SYSTEMS AT OTHER LOCATIONS. 4 RTA/CN 0205-24 2.A TYP EXTERIOR WALL ASSEMBLY TRANSLUCENT PANEL SYSTEM JOINT SEALANT CONT AIR BARRIER INSULATION FINISH PER SCHEDULE SHEATHING INSULATION FOR CAVITY WALL CMU VENEER 2.A 2X WOOD BLOCKING CMU VENEER TRANSLUCENT PANEL 1 0 4 .0 3 6 2 4 3 5 ° 2.C W12X35 PER STRUCTURAL METAL SOFFIT PANEL ALUMINUM FRAME FOR TRANSLUCENT PANEL SYSTEM METAL ANGLE TRANSLUCENT PANEL 2.D GRATING PANEL, WMP-6 FORMED METAL PANEL 1/4" BOLT ON Z CLIPS @ 12" O.C. METAL FLASHING AIR BARRIER ALUMINUM FRAME FOR PANEL SYSTEM INSULATION SHEATHING RIGID INSULATION CONT BACKER ROD AND SEALANT BOTH SIDES TRANSLUCENT PANEL SYSTEM 1'-2" 4X6 STL ATTACHMENT ANGLE MIN 1 1/2" AIR CAVITY 2.D METAL SILL FLASHING INSULATION INSULATION FOR FOUNDATION PERIMETER CONT BACKER ROD AND SEALANT BOTH SIDES TRANSLUCENT PANEL SYSTEM CONCRETE SLAB DAMPPROOFING FINISH GRADE / SIDEWALK SHEET METAL COVER 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:34:28 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AID909 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE DETAILS CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3" = 1'-0" BT120-APP221 JAMB DETAIL @ W5 WINDOW 1 SCALE: 3" = 1'-0" BT120-ARP321 HEAD DETAIL @ TRANSLUCENT WINDOW C SCALE: 3" = 1'-0" SOFFIT DETAIL @ OPEN SPACE B BT120-AES911SCALE: 3" = 1'-0" BT120-AES911 WINDOW HEAD DETAIL @ METAL GRATING A SCALE: 3" = 1'-0" BT120-AES911 SILL DETAIL @ METAL GRATING D 4 8 RTA/CN 0205-24 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:57 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APP231 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE FLOOR PLAN GANTRYJC DH CC JC DH CC 12/10/2024 469ISSUED FOR BID12/10/2024 1 06/13/2025 ADDENDUM #1 1 DELETED 1 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:46:59 PM 1/4" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEE832 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR ELEVATIONS GANTRYJC DH CC JC DH CC 12/10/2024 471ISSUED FOR BID12/10/2024 1 06/13/2025 ADDENDUM #1 1 DELETED 1 GANTRY 27' -0" 3.3 3.43.2 PRE FINISHED -BOX FRAMED PERFORATED ALUMINUM IMAGE PANELS. WMP-4 GANTRY TOP COS 56.750 GANTRY BOTTOM COS 47.750 2'-6" BOX FRAMED PERFORATED ALUMINUM METAL PANEL, WMP-5, TYP. BOX FRAMED PERFORATED ALUMINUM METAL PANEL, WMP-5, TYP. 8'-0" 9'-0" EQ EQ A BT120-AED910 CONCRETE PEDESTAL 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:33:44 PM 1/4" = 1'-0" BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEE833 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR ELEVATIONS GANTRY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE IN FEET 4 0 88 16 SCALE: 1/4" = 1'-0" BT120-APP231 GANTRY SOUTH ELEVATION - EAST HALF A 4 RTA/CN 0205-24 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:47:01 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEE834 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR ELEVATIONS GANTRYJC DH CC JC DH CC 12/10/2024 473ISSUED FOR BID12/10/2024 1 06/13/2025 ADDENDUM #1 1 DELETED 1 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:47:01 PM BT120 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ACP231 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE REFLECTED CEILING PLAN GANTRYJC DH CC JC DH CC 12/10/2024 474ISSUED FOR BID12/10/2024 1 06/13/2025 ADDENDUM #1 1 DELETED 1 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:47:02 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED910 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE GANTRY DETAILS GANTRYJC DH CC JC DH CC 12/10/2024 475ISSUED FOR BID12/10/2024 1 06/13/2025 ADDENDUM #1 1 DELETED 1 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:47:02 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APP241 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE FLOOR PLAN BEB EQUIPMENT YARDJC DH CC JC DH CC 12/10/2024 476ISSUED FOR BID12/10/2024 1 06/13/2025 ADDENDUM #1 1 DELETED 1 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:47:03 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ARP341 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE ROOF PLAN BEB EQUIPMENT YARDJC DH CC JC DH CC 12/10/2024 477ISSUED FOR BID12/10/2024 1 06/13/2025 ADDENDUM #1 1 DELETED 1 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:47:03 PM 3/16" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEE841 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR ELEVATIONS BEB EQUIPMENT YARDJC DH CC JC DH CC 3/16" = 1'-0" 12/10/2024 478ISSUED FOR BID12/10/2024 1 06/13/2025 ADDENDUM #1 1 DELETED 1 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:47:04 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-ACP241 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE REFLECTED CEILING PLAN BEB EQUIPMENT YARDJC DH CC JC DH CC 1/4" = 1' -0" 12/10/2024 479ISSUED FOR BID12/10/2024 1 06/13/2025 ADDENDUM #1 1 DELETED 1 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:47:04 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AED913 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE MISC DETAILS BEB EQUIPMENT YARDJC DH CC JC DH CC 3" = 1' -0" 12/10/2024 480ISSUED FOR BID12/10/2024 1 06/13/2025 ADDENDUM #1 1 DELETED 1 5.1 5.2 5.A 5.B A BT120-AEE851 B BT120-AEE851 C BT120-AEE851 D BT120-AEE851 501 17'-0 1/4" EDGE OF CONC SLAB, TYP 28'-6" SHEET NOTES: 1. FOR FENCE, GATE, AND DETAILS SEE BT120- CRD125 TO BT120-CRD127 2. PROVIDE HARDWARE SET HW-3 WITHOUT SWEEP AND THRESHOLD FOR GATE 501 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:47:05 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APP251 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE FLOOR PLAN GENERATOR PADJC DH CC JC DH CC 1/4" = 1' -0" 12/10/2024 481ISSUED FOR BID12/10/2024 SCALE IN FEET 2 44 80 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 1 06/13/2025 ADDENDUM #1 1 1 1 5.15.2 GENERATOR AT BKGD (3) EQS = 18'-0" BOLLARDS AT FOREGROUND. NOT SHOWN FOR CLARITY, TYP 5.A5.B PERFORATED SECURITY SCREEN, WMP-5, OVER METAL GATE & FENCE, TYP FENCE POST, TYP 1'-6"4'-6"(3) EQS = 23'-6" 4'-0" GATE 501 BOLLARDS AT THE FOREGROUND. NOT SHOWN FOR CLARITY, TYP TYP 8'-0" 5.1 5.2 (3) EQ = 18'-0" GENERATOR AT BKGD 5.A 5.B (4) EQ = 29'-6" GENERATOR AT BKGD SHEET NOTES: 1. FOR FENCE, GATE, AND DETAILS SEE BT120- CRD125 TO BT120-CRD127 2. PROVIDE HARDWARE SET HW-3 WITHOUT SWEEP AND THRESHOLD FOR GATE 501 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:47:06 PM 1/4" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEE851 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR ELEVATIONS GENERATOR PADJC DH CC JC DH CC 12/10/2024 482ISSUED FOR BID12/10/2024 SCALE: 1/4" = 1'-0" BT120-APP251 NORTH ELEVATION - GENERATOR A SCALE: 1/4" = 1'-0" BT120-APP251 EAST ELEVATION - GENERATOR B SCALE: 1/4" = 1'-0" BT120-APP251 SOUTH ELEVATION - GENERATOR C SCALE: 1/4" = 1'-0" BT120-APP251 WEST ELEVATION - GENERATOR D 1 06/13/2025 ADDENDUM #1 1 1 1 1 FIX2.3 2.J A BT120-AEE861 B BT120-AEE861 C BT120-AEE861 REFUSE AND RECYCLING AREA (3) EQ = FULL LENGTH FACE OF CORE FACILITY WALL CONT. STEEL PICKET FENCE GENERAL NOTES: SEE BT120-CRD125, BT120-CRD126, BT120-CRD127 & BT120-CGP102 FOR FENCE & GATE DETAILS & DIMENSIONS 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:47:06 PM As indicated BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-APP261 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE FLOOR PLAN REFUSE AND RECYCLING AREAJC DH CC JC DH CC 3/8" = 1' -0" 12/10/2024 483ISSUED FOR BID12/10/2024 SCALE IN FEET 024 4 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N 1 06/13/2025 ADDENDUM #1 1 1 1 CORE FACILITY 28' -2" ALUMINUM PERFORATED PLATE WALL PANEL, WMP-5, OVER METAL FENCE & GATE, TYP FACE OF CORE FACILITY WALL CORE FACILITY 28' -2" CORE FACILITY 28' -2" GENERAL NOTES: SEE BT120-CRD125, BT120-CRD126, BT120-CRD127 & BT120-CGP102 FOR FENCE & GATE DETAILS & DIMENSIONS 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:47:07 PM 1/4" = 1'-0" BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AEE861 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE EXTERIOR ELEVATIONS REFUSE AND RECYCLING AREAJC DH CC JC DH CC 12/10/2024 484ISSUED FOR BID12/10/2024 SCALE: 1/4" = 1'-0" BT120-APD225 NORTH ELEVATION REFUSE AND RECYCLING AREA ENCLOSURE A SCALE: 1/4" = 1'-0" BT120-APD225 SOUTH ELEVATION REFUSE AND RECYCLING AREA ENCLOSURE C SCALE: 1/4" = 1'-0" BT120-APP261 EAST ELEVATION REFUSE AND RECYCLING AREA ENCLOSURE B SCALE IN FEET 2 44 80 1 06/13/2025 ADDENDUM #1 1 1 1 SCHEDULED DOOR EXTERIOR THRESHOLD 1/2" 1/4" MAX 1/2" 1/2" FACE OF WALL SCHEDULED DOOR DOOR FRAME AT OPERATOR RESTROOM FLOOR FINISH PER SCHEDULE CO N C . SL A B SI D E WA L K FACE OF DOOR JAMB TILE THIN SET MORTAR BED WIDTH JAMB 2.C HSS 6 X 4 X 5/16 ALUMINUM FRAMING TRANSLUCENT PANEL SYSTEM TYPE I WITH ALUMINUM FRAME, PROVIDE DISSIMILAR METAL PROTECTION PAINTED METAL FLASHING 1/2" X 3" METAL VERTICAL PICKET RAILING, HPC-2, C-2 3" 1 1/2" 4 3/8" 1/2" 1/2" x 3" METAL TOP PLATE CONCRETE MASONRY LINTEL CONT. SEALANT HOLLOW METAL FRAME SCHEDULED DOOR 4" CMU VENEER 1 1/2"2" BOX FRAME, SEE STRUCT. DWGS 5/8" GWB R10 INSULATION R13 INSULATION STEEL ANGLE RIGID INSULATION SEALANT BOX BEAM WINDOW FRAME 4" CMU VENEER 5/8" GWB STEEL ANGLE BACKER ROD AND CONT. SEALANT R13 INSULATION BACKER ROD AND CONT. SEALANT EA. SIDE WINDOW FRAME METAL FLASHING R10 INSULATION 4" CMU VENEER 5/8" GWB CONT. SEALANT BOTH SIDES 4" CMU VENEER CONT. SEALANT SEE A/ BT120-AID900 FOR SIMILAR INFORMATION 2" 1 3/4"1 1/2"WINDOW FRAME BACKER ROD AND CONT. SEALANT SEE B/ BT120-AID900 FOR SIMILAR INFORMATION WINDOW FRAME INSULATION SEALANT BOX BEAM TRANSLUCENT PANEL SYSTEM METAL PANEL 5/8" GWB STEEL ANGLE BACKER ROD AND CONT. SEALANT WMP-6 1 1/2" AIR BARRIER WALL PANEL TO ATTACH STEEL FRAME, TYP ALUMINUM PERFORATED PLATE WALL PANEL, WMP-5, ATTACH TO FRAMING WITH TAMPER PROOF FASTENERS, TYP. FASTENER, TYP. SUPPORT CLIP, TYP. PLAN VIEW ACCESS DOOR ELEVATION @ BOTTOM @ TOP CONTIUOUS HINGE ALUMINUM PERFORATED PLATE WALL PANEL, WMP-5, ATTACH TO FRAMING WITH TAMPER PROOF FASTENERS, TYP. CAM LOCK WITH LATCH AND HOUSING AT TOP AND BOTTOM OF EACH ACCESS PANEL. CAM LOCK CORE SHALL BE IC CORE IN COMPLIANCE WITH ST HARDWARE REQUIREMENT PANEL SUPPORT FRAMING, TYP. PANEL FASTENER, TYP. STEEL SUPPORT FRAME, PAINTED, SEE DETAIL G/-FOR PANEL ATTACHMENT, TYP BOTTOM OF OUTRIGGER FACE OF WALL FINISH ALUMINUM PERFORATED PLATE WALL PANEL, WMP-5, ATTACH TO FRAMING WITH TAMPER PROOF FASTENERS, TYP. 3" B.O. CEILING KICKER METAL STUD, SECURED TO STRUCTUR ABOVE GYPSUM WALL BOARD 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:47:08 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AID900 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE DETAILS CORE FACILITYJC DH CC JC DH CC 12/10/2024 485ISSUED FOR BID12/10/2024 SCALE: 3" = 1'-0" DOOR - THRESHOLD D - SCALE: 3" = 1'-0" SILL DETAIL @ WINDOW & FENCE F BT120-ARP221 SCALE: 3" = 1'-0" DOOR - HEAD A -SCALE: 3" = 1'-0" WINDOW - HEAD B - SCALE: 3" = 1'-0" WINDOW - SILL E - SCALE: 3" = 1'-0" DOOR - JAMB 1 -SCALE: 3" = 1'-0" WINDOW - JAMB 2 - SCALE: 3" = 1'-0" BT120-AIX725 WINDOW - HEAD @ METAL SCREEN C SCALE: METAL PANEL SUPPORT G SCALE: 3" = 1'-0" ACCESS PANEL DOOR DETAILS H SCALE: 1" = 1'-0" METAL PANEL SUPPORT J 1 1 SCALE: 1 1/2" = 1'-0" SOFIT DETAIL K N.T.S. N.T.S. 1 06/13/2025 ADDENDUM #1 1 1 1 1 FINISH FLUSH WITH ADJACENT CEILING GROMMET/LATCH GYPSUM BOARD CASING BEAD ALL THE WAY AROUND 5/8" GYPSUM WALL BOARD 7/8" X 26 GAGE MINIMUM FURRING CHANNELS 1 1/2" X 1.12#/FT MINMAL CHANNEL FRAME AROUND OPENING PREMANUFACTURED CEILING ACCESS PANEL WITH RECESSED DOOR SECURED TO CHANNELS PER MANUFACTURER 8 GAGE HANGER WIRE WITH 3 TIGHT TURNS WITHIN 1 1/2" MTL STUD FRAMING BRACED TO ROOF FRAMING SEE WALL TYPES FOR DETAIL TOP OF STRUCTURE SUSPENDED MTL CEILING FRAMING BRACED AT PARTITION, TYP. BLKG, TYP. AT CEILING PERIMETER 5/8"THK GWB @ PARTITION & CEILING NOTE: SUSPENDED CEILING TO BE RATED AS REQUIRED TYP. TOP OF STRUCTURE SEE WALL TYPES FOR DETAIL MTL STUD FRAMING BRACED TO ROOF FRAMING ACOUSTICAL CEILING TILE, TYP. 5/8" THK GWB ON MTL STUD FRAMING HANGER WIRE @ ALL CORNERS TO STRUCTURE 1 1/2" CARRYING CHANNEL FRAMING ALL SIDES CONNECT TO ADJACENT MAIN RUNNER ACCESS PANEL MOUNTING FLANGE SEE REFLECTED CEILING PLAN FOR LOCATION & DIMENSION 0' - 2 5/32"SEE REFLECTED CEILING PLAN FOR LOCATION & DIMENSION CONTINUOUS EXTRUDED FLEXIBLE GASKET CONTINUOUS EXTRUDED ALUMINUM FRAME WALL AS SCHEDULED CEILING FRAME CONCEALED BY FEATHERED JOINT COMPOUND TEK SCREW 18" OC 4 5 .0 0 0 ° #12 GA HANGER WIRE (VERT.) @ 4 CORNERS CADDY #515 T-BAR CLIP FOR SECURING FIXTURE TO T-BAR GRID (4 PER FIXTURE) NOTE: ALL HANGER AND THE WIRES SHALL BE ANCHORED TO BUILDING STRUCTURAL MEMBERS. MINIMUM 4 TURNS WITHIN FIRST 1-1/2" (VERTICAL) T-BAR GRID (TYPICAL) #12 AWG TIE WIRE (45 DEGREE DIAGONAL) AT 4 CORNERS 4 5 .0 0 0 ° 4 5 .0 0 0 ° LIGHTING FIXTURE TIE WIRE TIE WIRE PLAN VIEW 45.000° D BT120-AID901 COMPRESSION POST WHERE REQ'D LOCATE @12' OC EACH DIRECTION SUSPENSION WIRE, SPLAY 4 -WAYS AND PLACE @ 45 DEGREES TO HORIZONTAL PARALLEL OF CEILING 'T'S 1/4" ∅BOLT MIN. MAIN CEILING RUNNER 'T' @4'-0" OC MIN. CROSS CEILING RUNNER 'T' @2'-0" OC MIN. T-BAR GRID LIGHT FIXTURE 12 GA. HANGERS @ 48" OC AND WITHIN 3" OF ANY FIXTURE WHERE LIGHT FIXTURES ARE IN TANDEM, COMMON HANGERS MAY BE USED. NOTE: PROVIDE 2 -12 GA. HANGERS FROM FIXTURE HOUSING TO CEILING SYSTEM HANGER OR TO STRUCTURE ABOVE. THESE MAY BE SLACK WIRES. WIRE TO BE STRAIGHT, WITHOUT EXTRANEOUS KINKS OR BENDS AND TOLERATE A 200 LB. PULL WITHOUT STRETCHING OR SHIFTING THE SUSPENSION CLIP. CLIP EACH FIXTURE TO GRID (CAPACITY OF EA. CLIP = 100% FIXTURE WEIGHT ACTING IN ANY DIRECTION) 2 BT120-AID901 WIRE WITH 3 TIGHT TURNS IN 1 1/2" EYE PIN EXPANSION STRUCTURE ABOVE 1 1/2" MIN. FIRST BRACING POINT FROM WALL WALL LINE 4-WAY -45° DIAGONAL 12 GA WIRE BRACING @ 8'-0" OC x 12'-0" & COMPRESSION STRUT (10 GA WIRE IF CEILING IS SUPPORTING PARTITIONS) MAIN 'T' BAR WALL LINE 12 GA VERTICAL HANGER WIRES @ 4'-0" OC EACH WAY CROSS 'T'-BAR TO 1ST 4'-0" MAX BR A C I N G UNSUPPORTED LENGTH OF T-BAR. 8" MAX. OR 1/4" WHICHEVER IS LESS. MAX 8" TYP. 2'-0"MAX 8"WALL LINE 4-WAY -45° DIAGONAL 12 GA WIRE BRACING @ 8'-0" OC x 12'-0" & COMPRESSION STRUT (10 GA WIRE IF CEILING IS SUPPORTING PARTITIONS) WALL LINE MAX 8" MAX 4'-8" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 25 G A 7 / 8 " H A T C H A N N E L S A T 5 / 8 " GY P . B D . C R O S S F U R R I N G : H . R . 1 " 41 # A T P L A S T E R . A BT120-AID901 SEE A/ BT120-AID901 FOR SIMILAR INFORMATION MTL STUD FRAMING BRACED TO ROOF FRAMING TOP OF STRUCTURE NOTE: SUSPENDED CEILING TO BE RATED AS REQUIRED TYP. SEE WALL TYPES FOR DETAIL 3/4" MIN CLEARANCE (PANEL FREE TO SLIDE) ACOUSTICAL CEILING TILE 5/8" GWB BOTH SIDES 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:34:15 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AID901 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE DETAILS CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3" = 1'-0" ACCESS PANEL - CEILING MOUNTED A - SCALE: 1/8" = 1'-0" TYP. GWB SUPPORT E -SCALE: 1/8" = 1'-0" TYP. ACT TRIM G - SCALE: 12" = 1'-0" ACCESS PANEL - INLAY B -SCALE: 6" = 1'-0" SUSPENDED/ ISOLATED GWB C - SCALE: 1/8" = 1'-0" TYP. RECESSED LUMINAIRE 2 -SCALE: 1/8" = 1'-0" TYP. SUSPENDED GRID 1 - SCALE: 1/4" = 1'-0" TYP. SUSPENSION WIRE @ STRUCTURE D - SCALE: 1/4" = 1'-0" SUSPENDED 2X2 GRID 4 -SCALE: 1/4" = 1'-0" SUSPENDED 2X4 GRID 3 - SCALE: 3" = 1'-0" ACOUSTICAL CEILING SUPPORT F - 48 RTA/CN 0205-24 4" COVED TOE TILE TO MATCH WALL TILE THIN SET MORTAR TOP OF SEALED CONCRETE SLAB SILICONE JOINT CEMENT BOARD WALL TILE AS SCHEDULED GROUT JOINT 6 " METAL STUDS AS SHOWN 6" X 16 GA. STL. PL. W 2 # 10 X 2" SMS 2 BAY MIN. E Q E Q S T D . S T U D S P A C I N G TYPE A: TOILET ACCESSORIES AND ALL ITEMS NOT OTHERWISE NOTED TYPE B: CABINETS AND COUNTERS UNLESS OTHERWISE NOTED 16 GA. BACKING CHANNEL OR PREFAB CHANNEL SET FLUSH W/ STUDS (TYP.) USE 14GA. @ TOILET PTN BACKING 16 GA. MIN. METAL STUDS, DEPTH OF STUDS AS REQ'D BY PTN. SCHED. 2 BAY MIN. E Q E Q S T D . S T U D S P A C I N G 1.5" 1/8"1/8" TYP 1/2"1/8" TYP DOOR AS SCHEDULED FACE OF DOOR FRAME CASING BEYOND THRESHOLD AS SCHEDULED SET IN FULL BED OF MASTIC FLOOR AS SCHEDULED CONCRETE SLAB ON GRADE SLOPE SLOPE RUBBER BASE TOP OF SEALED CONCRETE SLAB SILICONE JOINT 5/8" GWB WALL TYPE AS SCHEDULED STEEL BRACKET ANCHORED TO CMU WALL PER MFG WALL MOUNTED FIRE EXTINGUISHER 32 3/4" A.F.F. WALL AS SCHEDULED 4" 12" 7 3/4" PIANO HINGE GLASS VISION PANEL CABINET DOOR PULL SECTION 1A NOTE: TYP. MOUNTING HEIGHT IS 34" AFF TO CENTER OF CABINET INTEGRAL FIRE STOP WRAPPING CABINET INSERT PER ANSI/UL 1479 7 3/4" 4" 5/8" TYPE 'X' GYP BOARD ON MTL STUDS SPRING LOCK GLASS VISION PANEL CABINET DOOR PULL CABINET DOOR FIRE SEALANT AROUND ALL SIDES METAL STUDS UNFACED ROCK WOOL BATT INSULATION INTEGRAL FIRE STOP WRAPPING CABINET INSERT PER ANSI/UL 1479 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:34:17 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AID902 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE DETAILS CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3" = 1'-0" WALL TILE TO FLOOR A - SCALE: 3" = 1'-0" WALL BACKING 1 - SCALE: 6" = 1'-0" THRESHOLD C -SCALE: 6" = 1'-0" FLOOR DRAIN E -SCALE: 3" = 1'-0" WALL BASE B -SCALE: 1 1/2" = 1'-0" FIRE EXTINGUISHER - WALL MOUNTED D - SCALE: 1 1/2" = 1'-0" BT120-AIE821 FIRE EXTINGUISHER - RECESSED 2 48 RTA/CN 0205-24 TICKETSCOORDINATE WITH SOUND TRANSIT SIGNAGE STANDARDS FOR INSTALLING BT120- TVM DECALS TVM, NIC PEDESTAL TICKETS 4' - 0"IF TVM'S ARE PLACED ADJACENT TO EACH OTHER B BT120-AID903 ANCHOR 1/2" X 5 1/2" ANCHOR BOLT TVM PEDEST AL, NIC CONC SLAB SEE STRUCT METAL PANEL AS SCHEDULED SEALANT JOINT PER MFR 1' - 6 1/2" 1 1/4" 2' - 11 3/8" R 2' - 1 1 5/8" 4' - 0" 2' - 6" MINIMUM CLEARANCE DIMENSION FOR ENCLOSED TVM. (1" TYP.) OUTLINE OF EQUIPMENT AND OPNG CLEARANCE OUTLINE OF ADA PARALLEL APPROACH TVM EQ EQ 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:34:18 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AID903 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE DETAILS TRANSIT CENTER12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1" = 1'-0" BT120-APD101 TVM ELEVATION A SCALE: 3" = 1'-0" BT120-AID903 TVM BASE DETAIL B SCALE: 3/4" = 1'-0" BT120-APP213 TVM TYPICAL PLAN 1 488 RTA/CN 0205-24 2' - 0" NON-SLIP MICRO DOT SURFACE TEXTURE, TYP. 1" 1' - 10" 1" 1"1' - 10"1" 2' - 0" A BT120-AID904 F BT120-AID904 1"1 21/32" 3/4" NON-SLIP MICRO DOT SURFACE TEXTURE 7/16" 3/16" 27/32" R = 1/2" 1 21/32"1 21/32"1 21/32"1 21/32"1 21/32"1" PT-2 ON WET SET CONCRETE ROADWAY CONC PAD DRAINAGE MAT MORTAR MIX REINFORCED MORTAR BED - PC-2 CONCRETE CURB 9" TYP TOP OF SL PER CIVIL PLATFORM SLAB- SEE STRUCTRUAL FOR ADDITIONAL INFO ED G E OF T I L E CONT RUBBER RAIL TOP OF CRUSHED SURFACING MATERIAL -WHERE OCCURS 6"24". ROADWAY PLATFORM 3" 4" PB-1 CL SEALANT JOINT COMPRE SSIBLE FILLER 3/4" @ EJ 1/2" @ MJ - 9" TYP TOP OF SL PER CIVIL PLATFORM SLAB- ED G E OF T I L E TOP OF 6"24". ROADWAY PLATFORM 3" SEE C/ BT120-AID904 FOR SIMILAR INFORMATION PT-2 ON WET-SET CONCRETE MORTAR MIX PC-2 CL FLUSH GROUT JOINT FOR CALLOUTS AND DIMENSIONS IN COMMON, SEE 3/BTSTD-AFD101 1/4" PT-2 PT-2 ALIGN 2'X2' PT-2 JT WITH PLATFORM CONTROL JOINTS, TYP CL JOINT MORTAR MIX PC-2 CL SEALANT JOINT FLEXIBLE JOINT FILLER REINFORCEMENT 1/4" ALIGN LOWER PLANE OF TILE WITH LOWER PLAN OF RIBBED PAVER SEE C/ BT120-AID904 FOR SIMILAR INFORMATION CL JOINT STATION PLATFORM SLAB 1/2"CONCRETE PAVER CL JOINT A BT120-AID905 PLATFORM SLAB CRACK SUPPRESSION MEMBRANE THINSET MORTAR REINFORCED MORTAR BED DRAINAGE MAT CONC CURB, SEE STRUCT CRUSHED SURFACING MATERIAL 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:34:20 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AID904 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE DETAILS TRANSIT CENTER12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1 1/2" = 1'-0" BT120-AID907 PT-2 PLAN 1 SCALE: 6" = 1'-0" BT120-AID904 PT-2 SECTION A SCALE: 3" = 1'-0" BT120-AID907 PT-2 @ PLATFORM EDGE C SCALE: 12" = 1'-0" BT120-AID904 EXPANSION JOINT @ PT-2_DOC F SCALE: 3" = 1'-0" BT120-AID907 PT-2 @ PLATFORM EDGE B SCALE: 12" = 1'-0" BT120-AID905 JOINT DETAIL @ PC-2 D SCALE: 12" = 1'-0" BT120-AID907 JOINT DETAIL @ PT-2 E SCALE: 12" = 1'-0" BT120-AID905 JOINT DETAIL @ PT-2 TO PC-2 H SCALE: 3" = 1'-0" BT120-AID907 EXPANSION JOINT PLATFORM TYP J SCALE: 3" = 1'-0" BT120-AID907 PAVERS @ PLATFORM WAITING AREA G 489 RTA/CN 0205-24 TOPPING SLAB CONCRETE SLAB FO C COMPRESSIBLE FILLER 3/4" EN D O F PL A T F O R M CIP CONC PC-2 CL FLUSH GROUT JOINT FOR CALLOUTS AND DIMENSIONS IN COMMON, SEE 3/BTSTD- AFD101 1/4" PT-2 PC-2 PLATFORM SLAB DRAINAGE MAT H BT120-AID904 D BT120-AID904 3" 1'-0" CL OF JOINTS, TYP PT-2 CL JOINT A BT120-AID905 PLATFORM SLAB CRACK SUPPRESSION MEMBRANE THINSET MORTAR REINFORCED MORTAR BED DRAINAGE MAT CONC CURB, SEE STRUCT CRUSHED SURFACING MATERIAL CL JOINT STATION PLATFORM SLAB SLAB THICKNESS = T T/3 1/4" SAW CUT CONTROL JT - FILL JT WITH SEALANT THIN SET MORTAR TOPPING SLAB TOOLED CONCAVE SEALANT JOINT BOTH SIDES OF TACTILE PATH GRANITE PAVER CL SEALANT JOINT TACTILE STONE TILE, PB-1, TYP. 1/4" CRACK SUPPRESSION MEMBRANE FLEXIBLE JT FILLER CL JOINT CONTROL JOINT AT STRUCTURAL SLAB WHERE OCCURS PAVER OR TILE SEALANT OVER BACKER ROD COMPRESSIBLE FILLER STRUCT SLAB 1/2" CONC SIDEWALK, SEE CIVIL STATION PLATFORM SLAB BA C K F A C E OF PL A T F O R M B BT120-AID905 9" PLATFORM SLAB STRUCT ISOLATION JT C B CONCRETE PLATFORM /PC CONC PAVERS (PC-2)PER PLANS SHELTER FOUNDATION - SEE STRUCTURAL BACK FACE OF PLATFORM CRUSHED BASE COURSE - SEE STRUCT CIP CONC POUR BACK STRIP 2' - 0" UNO TOP OF PLATFORM 3" EXPANSION MATERIAL -AS REQ'D TOP OF FOUNDATION SEE STRUCT SYSTEMS/ELEC CONDUITS CIP CONC POUR BACK STRIP, NIC PT-2 REINFORCED MORTAR BED TOPPING SLAB ALIGN LOWER PLANE OF TILE WITH TOP OF TOPPING SLAB CL SEALANT JOINT THIN SET MORTAR CRACK SUPPRESSION MEMBRANE 1/4" 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:34:22 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AID905 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE DETAILS TRANSIT CENTER12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 12" = 1'-0" BT120-AID905 JOINT DETAIL @ PLATFORM END B SCALE: 12" = 1'-0" BT120-AID907 JOINT DETAIL @ PC PAVERS C BTSTD-AFD101 SCALE: 3" = 1'-0" BT120-AID907 PT-2 @ BUS #1 BOARDING ZONE F SCALE: 3" = 1'-0" BT120-AID907 PT-2 @ PLATFORM WAITING AREA G SCALE: 3" = 1'-0" MOVEMENT JOINT PLATFORM TYP H BTSTD-AFD101 SCALE: 12" = 1'-0" JOINT DETAIL @ CONCRETE TO PB-1 J -SCALE: 6" = 1'-0" MOVEMENT JOINT @ PAVER OR TILE, TYP K - SCALE: 3" = 1'-0" PLATFORM EDGE @ BACK E BTSTD-AFD101SCALE: 1" = 1'-0" FOUNDATION DETAIL @ PLATFORM D BTSTD-AEX101SCALE: 12" = 1'-0" BT120-AID904 JOINT DETAIL @ PT-2 TO CONCRETE A BTSTD-AFD101 49 RTA/CN 0205-24 BASE PLATE SST POST 2" X 3/4" 3" CL INTERIOR FACE OF CONCRETET CURB 3/4 x 2 PLATE STEEL POST, TYP. (4'-0" MAX O.C. PER PLAN) 3/4 x 1-1/2 PLATE STEEL, TYP. PLATE 4x6x3/8 TYP. W/ ANCHOR PLATFORM SLABTYP. 4 1/2" TOP OF PLATFORM TOP OF RAILING C CL GRADE -EL VARIES, SEE CIVIL3" 3'-6" 3'-1 1/2" 2'-9" 2'-4 1/2" 2'-0" 1'-7 1/2" 1'-3" 10 1/2" 5 1/4" 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:34:23 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AID906 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE DETAILS TRANSIT CENTER12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3" = 1'-0" BT120-APP212 STAINLESS RAILING (GDR-9) - PLAN 1 SCALE: 1 1/2" = 1'-0" BT120-AEX711 TYPICAL STAINLESS RAILING DETAIL A 49 RTA/CN 0205-24 PT-2, TYP. PRECAST CONCRETE PAVERS, PC-2, TYP. C BT120-AID905 E BT120-AID904 G BT120-AID905 G BT120-AID905 F BT120-AID905 J BT120-AID904 6' - 0" DIM POINT PER PLAN FULL TILE WIDTH 2' - 0" CONCRETE CURB CIP-1, SCORING LOCATE PER PLAN STATION PLANS 6' - 0" BUS FLAG, SEE STATION SITE PLANS, GENERAL NOTE 1. DIMENSION PER STATION PLANS 2' - 3" @ EJ ACCENT CONCRETE 6" 3'-6" B BT120-AID904 1 BT120-AID904 C BT120-AID904 G BT120-AID904 LITTER OR RECYCLE RECEPTACLE (W/ LINER REMOVED FOR CLARITY) (2) ANCHOR TABS W/ 7/16" Ø HOLES 4" 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:34:24 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AID907 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE DETAILS TRANSIT CENTER12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1" = 1'-0" BT120-APP213 ENLARGED PLAN - PLATFORM PAVING 1 SCALE: 3" = 1'-0" BT120-APP213 RECEPTACLE CLEARANCES - PLAN 2 49 RTA/CN 0205-24 STRUCTURAL SLAB 3/8" X 7" SS BOLTS RECEPTACLE ANCHOR TABS PER RECEPTACLE MANUFACTURER PC PAVERS REINFORCED MORTAR BED (2) SS WASHERS W/ ISOLATION PAD BETWEEN WASHER & PAVER EPOXY EMBEDMENT 5" STRUCTURAL ISOLATION JOINT CANOPY COLUMN SEALANT, BACKER ROD CONC "BLOCK- OUT" COMPRESSIBLE FILLER C BT120-AID908 MOUNTING POST BY SEATING SYSTEM MFR STEEL TIE-ROD M16 SS THREADED ROD ADHESIVE ANCHOR SUPPLIED BY SEATING SYSTEM MFR STRUCTURAL SLAB TOPPING SLAB SS WASHER BY SEATING SYSTEM MFR MIN. 5" STRUCTURA L ISOLATION JOINT COLUMN CONC SEALANT OVER BACKER ROD COMPRESSI BLE FILLER 3/4" HSS COLUMN COMPRESSIBLE FILLER SAWCUT JOINT C BT120-AID908 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:34:26 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG J. CHAN D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AID908 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE DETAILS TRANSIT CENTER12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3" = 1'-0" BT120-AEE815 LITTER RECEPTACLE ANCHOR A SCALE: 3" = 1'-0" EXPANSION JT @ STRUCTURE B -SCALE: 3" = 1'-0" BT120-AEE812 BENCH SEATING POST ANCHOR D SCALE: 6" = 1'-0" BT120-AID908 COLUMN EXPANSION JOINT C SCALE: 3" = 1'-0" JOINT DETAIL @ HSS COLUMN 1 - 49 RTA/CN 0205-24 NOTE: 48" MINIMUM IF DOOR HAS BOTH A LATCH AND CLOSER 44" MIN. 60" 54" MIN. 36" MIN. PULL SIDE PUSH SIDE FRONT APPROACH HINGE APPROACH MIN. 12" @ EXT. DOOR 24" MIN. CLR. @ INT. DOOR 18" MIN. CLR.60" MIN. 48" MIN. PUSH SIDE PULL SIDE PULL SIDE INTERIOR DOOR DOORS IN SERIES 18" 12" 48" 60" MIN. MIN. 18" PULL SIDE INTERIOR DOOR 32"MIN. 90.000° 48" MAX. 15" MIN. HIGH AND LOW SIDE REACH LIMIT 10" MAX. 46" MAX. MAXIMUM REACH OVER OBSTRUCTION 30" 34" 24" MAX 36" MIN. 9" MIN. 8" MIN KNEE CLEARANCE 27" MIN. 18" TO 19" 6"6" MAX.-TOE CLEARANCE 11" 18" MIN. 32" MIN. 48" MIN. 30" MIN. CLEAR FLOOR SPACE AT DRINKING FOUNTAIN ALCOVES CONTINOUS PASSAGE 36" MIN. CLR POINT PASSAGE 32" MIN CLR 4" 24" MAX DIMENSION ANY WING WALLS DOWN TO FLOOR ADDITIONAL PROTECTION NOT REQUIRED BETWEEN WING WALLS PROTRUDING OBJECTS HANGING ON WALL WITH LEADING EDGES ABOVE 27" WING WALLS DOWN TO FLOOR THAN 27" WHEN HIGHER WALKING PARALLEL TO A WALL 4" MAX.LOBBY 80" MIN. 5"MAX 15"MIN X > 8" FLOOR SPACE 30" CLEAR FLOOR SPACE 48" CLEAR FLOOR SPACE 30" CLEAR FLOOR SPACE 48" CLEAR FORWARD APPROACH PARALLEL APPROACH 48" 15" MIN. 67" DIAMETER SPACE T-SHAPE TURN SPACE 36" MIN.12" MIN.12" MIN. 36" MIN. 60" MIN. HIGH FORWARD REACH LIMIT PARALLEL APPROACH 60" >15" 44" 60" FORWARD APPROACH > 24" 36" 44" OBSTRUCTED FORWARD REACH LIMIT >20"-25" MAX SIDE REACH LIMIT 48" MAX 15" MIN. 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:34:31 PM 1/2" = 1'-0" BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AID910 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE DETAILS CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 1/2" = 1'-0" FRONT APPROACH & SIDE CLEARANCES 1 - SCALE: 1/2" = 1'-0" APPROACH AND REACH 2 - 494 RTA/CN 0205-24 36" STAINLESS STEEL GRAB BAR (TA-6) 42" STAINLESS STEEL GRAB BAR TOILET TISSUE DISPENSER (TA-1) TOILET SEAT COVER DISPENSER (TA-5) 18" STAINLESS STEEL GRAB BAR 40" AFF 17" - 19" 36" MAX AFF 33" MIN & 10"-12" 15" MIN 12" MAX RESTROOMS TRANSFE R SIDE 24"12" 16" - 18" GRAB BAR 36" MIN. REAR GRAB BAR ALLOWED AT 36" A.F.F. AT TANK-TYPE TOILET 18"13 1/2" MIN. 17" MIN. WALL MOUNTED URINAL 28 3/8" 39" - 41" 44" MAX 16"-18" 48" 12" AFF COAT HOOK (TA-8)MIRROR W/ SHELF SOAP DISPENSER (TA-3) SANITARY NAPKIN VENDOR DISPENSER (TA-12) FIRE EXTINGUISHER (CABINET) JANITOR ROOM F.E.C. SURFACE MOUNTED WASTE RECEPTACLE UNIT (TA-11) SINK W/ UBP (TA-10) 36" MIN 48" MAX AFF 12". MOP SINK TO LATCH 34" 40" MAX 34" AFF 54"MAX 40" AFF HAND DRYER (TA-7) 1/4" 2 1 1/4" MAX 1/2" MAX MAX 1 1/4" 2 AT 1:2 SLOPE FINISH FLOOR EVEN COMPRESSED CARPET 1/4" MAX BELOW THRESHOLD 1/2" 6" X 16 GA. STL. PLATE FASTEN TO (2) STUDS, MIN. (3) STAINLESS STEEL R.H.M.S. W/PIPE SPACER (1) LAYER OF W.R. 5/8" GYP. BD. AS OCCURS TILE (WHERE OCCURS) 2. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF A 250-POUND POINT LOAD SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR MATERIAL OF A GRAB BAR OR SEAT, AND IT'S MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND TORSIONAL SHEAR STRESSES SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS. 3. SHEAR FORCE INDUCED IN FASTENER OR MOUNTING DEVICE FROM THE APPLICATION OF A 250-POUND POINT, LOAD SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OR EITHER THE FASTENER OR MOUNTING DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER IS THE SMALLER ALLOWABLE LOAD. 4. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF A 250-POUND POINT LOAD, PLUS THE MAXIMUM MOMENT FROM THE APPLICATION OF A 250-POUND POINT LOAD SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN THE FASTENER AND THE SUPPORTING STRUCTURE. 5. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. LOCATIONS: GRAB BARS LOCATED ON EACH SIDE, OR ONE SIDE AND BACK OF THE ACCESSIBLE TOILETS STALL OR COMPARTMENTS, SHALL BE SECURELY ATTACHED 33 INCHES ABOVE AND PARALLEL TO THE FLOOR EXCEPT THAT WHERE A TANK-TYPE TOILET IS USED WHICH OBSTRUCTS PLACEMENT AT 33 INCHES, THE GRAB BAR MAY BE AS HIGH AS 36 INCHES. GRAB BAR SHALL BE AT LEAST 42 INCHES FRONT OF WATER CLOSET STOOL GRAB BAR AT THE BACK SHALL NOT BE LESS THAN 36" LONG, DIAMETER OR WIDTH: THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES' OF GRAB BAR SHALL BE 1 1/4" to 1 1/2" OR SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. IF GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND GRAB BARS SHALL BE 1 1/2" STRUCTURAL STRENGTH: THE STRUCTURAL STRENGTH OF GRAB BARS, TUB AND SHOWERS SEATS, FASTENERS AND MOUNTING DEVICES SHALL MEET THE FOLLOWING SPECIFICATIONS: 1. BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE APPLICATION OF 250-POUNDS POINT LOAD SHALL BE LESS THAN ALLOWABLE STRESS FOR MATERIAL OF GRAB BAR SEAT. +34" A.F.F. 1 1/2" 6 7 " M I N . D I A M E T E R C L E A R 30" X 40" CLEAR SPACE 30" X 40" CLEAR SPACE 60" MIN. 56" MIN. 3'-6" MIN 1'-0" 16"-18" MIN 3'-0" 6" 25 1/2" 6" MAX8" MIN INSULATE DRAIN LINE & HOT WATER PIPE 9" MIN. 17" MIN 34" 27 1/2" 31 1/4" TO CENTERLINE 18" MIN. 17" MIN. 48" MIN.19" MAX. 30" MIN. CLEAR FLOOR SPACE NOTE: IF A MINIMUM 9 INCHES HEIGHT TO TOE CLEARANCE IS PROVIDED, A MAXIMUM OF 6 INCHES OF THE 48 INCHES OF CLEAR FLOOR SPACE REQUIRED AT THE FIXTURE MAY EXTEND INTO THE TOE SPACE. SIDE VIEW PLAN VIEW 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:34:33 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AID911 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE DETAILS CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3/4" = 1'-0" TYPICAL MOUNTING HEIGHT A - SCALE: 3/4" = 1'-0" ADA - CHANGE IN LEVEL B -SCALE: 1" = 1'-0" GRAB BAR MOUNTING DETAIL C SCALE: 1/2" = 1'-0" BT120-APD223 ADA -SINGLE ACCOMMODATION TOILETS 1 SCALE: 3/4" = 1'-0" LAVATORY CLEARANCE 2 - 49 RTA/CN 0205-24 3/4" PLYWOOD W/ PLASTIC LAMINATE FINISH 1/4" PLYWOOD BACKING, TYP. PROVIDE BLOCKING AS REQUIRED OPERABLE DOOR w/ ATTACHED BASE (FOR KNEE SPACE IN COMPLIANCE WITH ADA REQUIREMENT) SOLID SURFACE COUNTERTOP AND BACKSPLASH AS SPECIFIED OVER 3/4" PLYWOOD SUBSTRATE CABINET HARDWARE AS SPECIFIED 4" 30" 4" PIPE WRAP OR PREFORMED FOAM INSULATION 3/4" PLYWOOD W/ PLASTIC LAMINATE FINISH DOORS PROVIDE WOOD BLOCKING AS REQUIRED 84" CABINET HARDWARE AS SPECIFIED 24" 60" ADJUSTABLE SHELVES AS INDICATED ON INTERIOR ELEVATIONS 15" 1/4" 30" @ ADA COUNTER 36". 2" METAL BLOCKING AS DETAILED COMMERCIALLY AVAILABLE COUNTERTOP BRACKET SUPPORTS SPACED @ 48" O.C. (MAX.) COUNTERTOP MATERIALS PER PLAN ON 3/4" PLYWOOD SUBSTRATE BASE -SEE FINISH SCHEDULE 3/4" FIRE RATED PLYWOOD, DO NOT COVER LABEL ATTACH SCREWS 24" OC ON WALL FRAMING ATTACH SCREWS 24" OC ON WALL FRAMING WALL TYPE AS SCHEDULED 12" 9'-0" A.F.F. 2" WIDE 16 GA STEEL STRAPS TO SPAN FLUTE & OVERLAP ADJACENT DECK VALLEYS BY 1 1/2" SPACED 24" O.C. PARALLEL TO FLUTES PERPENDICULAR TO FLUTES ACOUSTICAL INSULATION SEALANT METAL STRUCTURAL DECK CONINUOUS SLOTTED TOP TRACK SEE STRUCT. PARTITION TYPE PER PLANS 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 6/2/2025 4:47:08 PM BT120 0 S1-BT120-A-v2020 RTA/OA 0206-19 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AID912 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE DETAILS CORE FACILITYJC DH CC JC DH CC 12/10/2024 496ISSUED FOR BID12/10/2024 SCALE: 1 1/2" = 1'-0"BT120-AIE822 CASEWORK - CABINET WITH SINK A SCALE: 1 1/2" = 1'-0"BT120-AIE821 COUNTER SECTION B SCALE: 1 1/2" = 1'-0" BT120-APD224 PLYWOOD BACKER C SCALE: 3" = 1'-0" BT120-AIX725 TOP OF WALL ( NON-RATED) CONDITIONS D 1 06/13/2025 ADDENDUM #1 1 1 1 9" 101 BORDER COLOR 9" ROOM NAME ROOM NUMBER BACKGROUND COLORROOM NAME MESSAGE COLOR BRAILLE MESSAGE, TYPICAL 3" 6" 9" UNISEX ABA GRAPHIC BACKGROUND COLOR ROOM NAME MESSAGE COLOR BRAILLE MESSAGE 48" MIN. TACTILE "EXIT" SIGN (CENTERED ON 1'-6" SPACE) 703.4.4 HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OR GROUND 703.4.2 LOCATION OF TACTILE SIGNS AT DOORS 60" MIN. 1'-6" EQ EQ 48" MIN. TACTILE "EXIT" SIGN (CENTERED ON 1'-6" SPACE) 60" MIN. 1'-6" EQ EQ 9" 9"MAX OCCUPANTS ### REFER TO LIFE SAFETY SHEETS PER ROOM 9" 9"NO SMOKING WITHIN 50 FT OF BUILDING MESSAGE COLOR 1'-2" EXIT GRADE 2 BRAILLE PER CBC TABLE 11B-703.3.1 8" 2'-6" 00001'-6" EQ EQ 4 1/2" 9" 4 1/2" . 24" FROM CORNER . 24 " F R O M C O R N E R NOTE: 1. SEE ELEVATIONS FOR LOCATIONS, FINAL LOCATION PER BASE REPRESENTATIVE APPROVAL. 2. SIGN TO BE MOUNTED A MINIMUM OF 10'-0" ABOVE GROUND IN VISIBLE LOCATION. 3. NUMBER SHOWN IN THIS DETAIL IS FOR EXAMPLE ONLY. CONFIRM ACTUAL BUILDING NUMBER WITH BASE REPRESENTATIVE. 4. COLORS TO BE MATCHED WITH THE BASE DISTRICT/ AREA ACCENT COLOR 3/16 HEX HEAD BOLT WITH ANCHOR 1/4" WIDE REFLECTIVE BAND COLOR: REFLECTIVE WHITE 230-000 9" HIGH VINYL CUT LETTERS HELVETICA MEDIUM COLOR: REFLECTIVE WHITE 230-000 METAL SIGN PANEL, BOLTED TO WALL COLOR: AYERS ROCK 7826A SIGN PANEL (.080 ALUMINUM SHEET) 1/4" NEOPRENE SPACER WALL TYPE PER PLAN 9849 REGISTERED ARCHITECT CHAN LAM CHEANG STATE OF WASHINGTON DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BIM 360://US WA_D3458600_BUS_RAPID_TRANSIT_GEC/S1-BT120-A-v2020.rvt 11/15/2024 4:34:35 PM BT120 S1-BT120-A-v2020 12/10/2024 12/10/2024 C. CHEANG A. DOMINGO D. HOGAN C. CHEANG STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-AID913 12/10/2024R. PARGAS J. ALTCHECH ARCHITECTURE DETAILS CORE FACILITY12/10/2024 J.C. D.H. C.C. ISSUED FOR BID12/10/2024 ISSUED FOR BID SCALE: 3" = 1'-0" SIGNAGE - ROOM ID E - SCALE: 3" = 1'-0" SIGNAGE - UNISEX_DOC G - SCALE: 1/2" = 1'-0" SIGNAGE - MOUNTING HEIGHT A - SCALE: 3" = 1'-0" SIGNAGE - MAX OCCUPANCY (ROOM)C -SCALE: 3" = 1'-0" SIGNAGE - NO SMOKING D -SCALE: 3" = 1'-0" SIGNAGE - EXIT F - SCALE: 1 1/2" = 1'-0" SIGNAGE - BUILDING NUMBER B - 49 RTA/CN 0205-24 LEGEND PIPING SYMBOLS EQUIPMENT CLEARANCE EQUIPMENT SYMBOLS PITCH DOWN IN DIRECTION OF ARROW LINE/WALL CLEANOUT A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. P. Q. REFER TO GEN-GZN006 AND GEN-GZN007 FOR ADDITIONAL SYMBOLS AND LEGEND. REFER TO SPECIFICATIONS FOR MATERIALS AND METHODS FOR CONSTRUCTION. COORDINATE THE EXACT LOCATION OF FLOOR DRAINS WITH THE ARCHITECTURAL DRAWINGS AND MECHANICAL EQUIPMENT LOCATIONS PRIOR TO INSTALLATION OF DRAINS. COORDINATE ACCESS DOORS FOR INSTALLATION IN WALLS AND CEILINGS WHERE ACCESS IS REQUIRED TO CONCEALED PLUMBING EQUIPMENT, VALVES, CONTROLS, AND OTHER DEVICES. PERFORM WORK IN ACCORDANCE WITH THE LATEST EDITIONS, REVISIONS, AMENDMENTS OR SUPPLEMENTS OF APPLICABLE STATUTES, ORDINANCES, CODES, OR REGULATIONS OF FEDERAL, STATE AND LOCAL AUTHORITIES HAVING JURISDICTION IN EFFECT ON THE DATE BIDS ARE RECEIVED. AS OF JAN 2023, WAC VERSIONS OF: 2018 IBC, 2018 UPC. COORDINATE WORK WITH ARCHITECTURAL FEATURES AND COORDINATE WORK SUCH THAT INTERFERENCES BETWEEN PIPING, DUCTWORK, EQUIPMENT, PLUMBING WORK, ELECTRICAL WORK, BUILDING STRUCTURE WILL BE AVOIDED. PROVIDE THE ENTIRE SYSTEM AND ITS COMPONENT ITEMS OF EQUIPMENT IN OPERATING CONDITION WITHOUT OBJECTIONABLE VIBRATION OR NOISE. PROVIDE WATER HAMMER ARRESTERS AT RESTROOM PLUMBING CHASES. PROVIDE ALL WIRING AND ELECTRICAL CONTROLS IN ACCORDANCE WITH NFPA 70 (NEC). VERIFY AND DOCUMENT EXISTING CONDITIONS AND DIMENSIONS ON THE JOB SITE PRIOR TO STARTING ANY WORK. DO NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES. INSTALL PIPING TO PROVIDE THE MAXIMUM POSSIBLE CLEAR HEIGHT UNDERNEATH WHILE COORDINATING WITH OTHER TRADES. MAINTAIN A MINIMUM OF 6" ABOVE FINISHED CEILING TO PROVIDE CLEARANCE FOR LIGHTING FIXTURES. PROVIDE FINAL CONNECTIONS TO EQUIPMENT. LOCATE VENT TERMINALS A MINIMUM OF 10' HORIZONTALLY FROM ANY DOOR, OPERABLE WINDOW, OR OTHER AIR INTAKE OF THE BUILDING OR ADJACENT BUILDING UNLESS THE VENT TERMINAL IS AT LEAST 2' ABOVE THE TOP OF SUCH OPENING. EXTEND ALL VENT LINES VERTICALLY (45 DEGREE ANGLE OR GREATER FROM HORIZONTAL) TO MINIMUM OF 6" ABOVE THE HIGHEST FLOOR LEVEL RIM OF THE HIGHEST FIXTURE SERVED BY VENT. ALL SANITARY SEWER BRANCH LINES SHALL DROP TO THE SAME ELEVATION AS THE SANITARY SEWER MAIN LINES UTILIZING A MAXIMUM SLOPE OF 45 DEGREES. ALL SANITARY SEWER PIPING SHALL BE SLOPED AT 1/4" PER FOOT MINIMUM. SEE ARCHITECTURAL, MECHANICAL, CIVIL, ELECTRICAL AND ROOM FINISH DRAWINGS FOR LOCATION OF EQUIPMENT AND FIXTURES. HANDLE, STORE, AND INSTALL EQUIPMENT ACCORDING TO MANUFACTURER'S INSTRUCTIONS. CLEANOUT HOSE BIBB, WALL HYDRANT FLOOR DRAIN P-TRAP VALVE SYMBOLS CHECK VALVE (NON SLAM) STRAINER GATE VALVE PRESSURE REDUCING VALVE (PRV) BALL VALVE GENERAL NOTES A. B. C. D. PER C404.3.1 THE MAXIMUM LENGTH OF PIPING OF DOMESTIC HOT WATER FROM SOURCE OF HEATED WATER IS 3 FEET FOR 3/8" PIPE SIZE. PER C404.10.3 INSULATE DOMESTIC HOT WATER PIPING TO TABLE 403.10.3. PIPE SIZE <1", INSULATION THICKNESS 1". INSULATE DOMESTIC COLD WATER PIPING WITH 1/2" THICK INSULATION IF <1.5", OTHERWISE 1" THICK INSULATION. PIPE INSULATION SHALL BE CONTINUOUS TP PREVENT THERMAL BRIDGING. PER C408.1.4 PRIOR TO FINAL PLUMBING INSPECTIONS OR OBTAINING CERTIFICATE OF OCCUPANCY, THE CERTIFIED COMMISSIONING PERFESSIONAL SHALL PROVIDE EVIDENCE OF BUILDING COMMISSIONING. WASHINGTON STATE ENERGY CODE NOTES FOR PLUMBING UNION ABBREVIATIONS VE SANITARY VENT NPW NON-POTABLE WATER WATER HAMMER ARRESTER PRESSURE GAUGE WITH COCK WALL HUNG WATER CLOSET WALL HUNG URINAL WALL HUNG LAVATORY DROP-IN SINK BUILDING CLEANOUTBCO SINKS PLUG CLEANOUTPCO FLOOR SINKFS HUB DRAINHD MOP SINKMS URINALURN PRESSURE GAUGEPG REDUCED PRESSURE BACKFLOW ASSEMBLY RPBA WATER HAMMER ARRESTERWHA HANDICAPPEDHC BASIS OF DESIGNBOD WASHINGTON STATE PLUMBING CODE 2021 (UPC 2021 AMMENDED) WASHINGTON STATE COMMERCIAL ENERGY CODE 2021 (IECC 2021 AMMENDED) APPLICABLE CODES TO PLUMBING REFER TO GEN-GZN006 & GEN-GZN007 FOR ADDITIONAL SYMBOLS AND LEGEND 1 BT120-MPP222 12 37 2.112.102.92.82.7 2.6 2.52.42.32.22.1 2.H 2.C 2.F 4" SS 1% SLOPE 4" SS N 2 BT120-MPP222 ELECTRICAL BT120L1209 SECURITY BLDG BT120L1200 STORAGE 1 BT120L1210 39 38 TELECOM BT120L1208 PCO 3" VE 2.112.102.92.82.72.62.52.42.32.22.1 2.H 2.C 2.F LACTATION ROOM BT120L1202 SEC STORAGE BT120L1201JANITOR BT120L1203 OPERATOR RESTROOM BT120L1204 OPERATOR RESTROOM BT120L1206 N OPERATOR RESTROOM BT120L1207 OPERATOR RESTROOM BT120L1206 OPERATOR RESTROOM BT120L1205 OPERATOR RESTROOM BT120L1204 JANITOR BT120L1203 LACTATION ROOM BT120L1202 SEC STORAGE BT120L1201 2" DCW WC-1 WC-1 FD-1 WC-1 WC-1 FD-1 FD-1 FD-1 FD-1 18 BT120-BFP-02 BT120-BFP-01 BT120-PRV-01 1" NPW MS-1 1919 19 2" DCW 1717 HB-1HB-1 HB-1HB-1 WCOWCO 20 BCO 21 21212121 22 2222 S-2 BT120-EWH-04 WHA 37 26 FCV 2.92.82.72.62.5 BT120-EWH-06 BT120-EWH-03 S-1 BT120-EWH-05 BT120-EWH-02 UR-1UR-1 L-1L-1 UR-1 UR-1 L-1L-1 BT120-EWH-01 25 38 FCO BCO 20 HB-2 HB-3 3/4" DCW WHA HB-2 SECURITY BLDG BT120L1200 1" DCW 2" DCW 1" NPW 4" SS 4" SS 3412 14 2 7 1 6 10 1313 9 11 15 1 5 1 8 4" SS 1/2" TP 4" SS 1/2" TP 10 1010 10 1/2" TP 9 11 1 5 1 8 4" SS 1/2" TP 24 25 1" DCW 23 23 23 2.92.82.72.62.5 27 2" DOMESTIC WATER SERVICE -REFER TO CIVIL FOR CONTINUATION I.E. = -3'-5" BFFI.E. = -3'-0" BFF 4" SANITARY SEWER -REFER TO CIVIL FOR CONTINUATION 4" SANITARY SEWER -REFER TO CIVIL FOR CONTINUATION 15 40 2% SLOPE 2% SLOPE2" SS 3" SS3" SS 4" SS 1" NON-POTABLE WATER -REFER TO CIVIL FOR CONTINUATION 4" SS 1/2" TP 1% SLOPE 4" SS N 3" VENT THROUGH ROOF 3" VENT THROUGH ROOF 3" VENT THROUGH ROOF 3" VENT THROUGH ROOF 2" VENT THROUGH ROOF 2.112.102.92.8 2.72.62.52.42.32.22.1 2.H 2.C 2.F N 2" DCW UP THROUGH FLOOR 2" DOMESTIC WATER SERVICE -REFER TO CIVIL FOR CONTINUATION S-2 BT120-EWH-04WHA 1" DCW 1" DCW ROUTED UNDERGROUND TO SECURITY OFFICE PG BT120-PRV-01 PG BT120-BFP-02 BT120-BFP-01 FCV MS-1 1" NPW WC-1 WC-1 1" DCW 1 1/2" DCW 2" DCW 1 1/2" DCW 1" DCW HB-1 HB-1 3/4" DCW 1" DCW DOWN THROUGH FLOOR HB-1 3/4" DCW HB-1 WC-1 WHA 1 1/2" DCW WC-1 1 1/2" DCW 1" DCW 3/4" DCW WHA 2" DCW 2" DCW 2" DCW 1 1/4" DCW 2" DL S-1 1" NPW DOWN THROUGH FLOOR BT120-EWH-03 BT120-EWH-06 BT120-EWH-05 1/2" DCW BT120-EWH-01UR-1 L-1 L-1 UR-1 UR-1 L-1 BT120-EWH-02 L-1 UR-1 2" DCW 3/4" DCW WHA 3/4" DCW HB-2 HB-3 HB-2 WHA 1" DCW 1" NON-POTABLE WATER -REFER TO CIVIL FOR CONTINUATION 1/2" DHW TYPICAL HVAC CONTRACTOR TO RUN CONDENSATE TUBE FROM INDOOR CONDENSOR TO INDIRECT DRAIN, COORDINATE TEE PLACEMENT WITH HVAC ERU-01 CLEANOUT CAP OR PLUG (TYPICAL)CD AIR GAP INTO MOP SINK ALL TEES, ELBOWS, INDIRECT DRAIN PIPE AND THREADED CLEANOUT CAPS OR PLUGS IN 2" PVC, MINIMUM SLOPE OF 1%. PIPING NOT SHOWN ON PLUMBING FLOOR PLAN. SEE HVAC FOR LOCATIONS OF UNITS. NOTES: ACU-56ACU-46 AIR GAP INTO 3" HUB DRAIN AT CONFORT STATION 2 ACU-36ACU-26 AIR GAP INTO 3" HUB DRAIN AT CONFORT STATION 4 ACU-16 ACU-05 ACU-01 CD ACU-04ACU-03 CD AIR GAP INTO 3" HUB DRAIN AT CONFORT STATION 4 ACU-02 SEPARATE PENETRATIONS INTO STORAGE ROOM FROM ELECTRICAL ROOM ACU-07 CONDENSATE TUBE INTO PIPE TO CONDENSATE TRAP 1" NPW ROUTED UNDERGROUND TO PLATFORM HOSE BIBBS 1/2" BALL VALVE SET AT 18" AFF (WINTER RELIEF) ISOLATION1" BALL VALVE AT 24" AFF 1" NPW 1" NPW 1" NPW CAPPED MINIMUM OF 12" AFF FOR FUTURE USE 4" DOUBLE TWO-WAY CLEANOUT 3" VE 4" DOUBLE TWO-WAY CLEANOUT 3" VENT THROUGH ROOF 4" HUB DRAIN (8" x 4" REDUCER) 2" HUB DRAIN (3" x 2" REDUCER) 2" HUB DRAIN (3" x 2" REDUCER) DROP 4" SANITARY SEWER TO LOWER ELEVATION 4" SS 3" SS MS-1 3" VENT THROUGH ROOF 3" VENT THROUGH ROOF FD-1 FD-1 WCO 4" SS 4" SS 4" SS4" SS 2" VE 4" SS 4" SS 2" SS 4" SS WC-1 WC-1 3" VE 2" VE FD-1 WC-1 WC-1 WCO 2" VE 3" SS 4" SS 4" SS 4" SS 2" SS 4" SS 2" VE 3" VE 3" VE 1/2" TP 1/2" TP S-2 2" VE 2" VE 2" VENT THROUGH ROOF 3" SS S-1 WCO UR-1 L-1 L-1 UR-1 FD-1 L-1 UR-1 FD-1 1/2" TP WCO PROVIDE TAILPIECE WITH 3/4" CONNECTION FOR CONDENSATE DRAIN 3/4" CONDENSATE DRAIN - REFER TO HVAC DRAWINGS 4" SANITARY SEWER -REFER TO CIVIL FOR CONTINUATION 4" SANITARY SEWER -REFER TO CIVIL FOR CONTINUATION BCO 3" SS 4" SS 4" SS 2 % S LO P E 3" SS 3" SS FCO 2" SS 1/2" TP 3" SS 3" VE 3" VE 2 % S L O P E 1/2" TP 2" VE 2" VE 2" VE 2" VE 3" VE 3" VE UR-1 1 % SL O P E4" SS 4" SS 4" HUB DRAIN (8" x 4" REDUCER) 3" VENT THROUGH ROOF 4" SS PCO 3" VE 4" SS 4" SS 1 % S L OPE PLUMBING FIXTURE SCHEDULE WALL HUNG WATER CLOSET TAG DESCRIPTION AUTOMATIC FLUSH VALVE 1.28 GALLONS PER FLUSH AMERICAN STANDARD: SELECTRONIC WC-1 ADDITIONAL DESCRIPTION DIMENSIONS MANUFACTURER (BOD) MODEL NO. (BOD) 26" x 14" x 15"AMERICAN STANDARD AFWALL 2257.101 WASTE PIPE VENT PIPE DCW DHW 4"2"1"NA FAUCET OR VALVE (BOD)REMARKS 1, 3, 4 WALL HUNG URINAL AUTOMATIC FLUSH VALVE 1 PINT PER FLUSH AMERICAN STANDARD: SELECTRONIC UR-1 14" x 18" x 26"AMERICAN STANDARD WASHBROOK 6590.530 2"1 1/2"3/4"NA 1, 4, 7 L-1 S-1 MS-1 HB-1 PG TP AMERICAN STANDARDAUTOMATIC ELECTONIC FAUCET 0.5 GPM DUAL BEAM WALL HUNG LAVATORY 20" x 18" VITREOUS CHINA LUCERNE 0356 2"1/2"1/2"CHICAGO: ELECTRONIC 1, 2, 4, 8 ELKAYSINGLE BOWL TOP MOUNT SATIN 316L SS LACTATION ROOM SINK 25" x 22" x 12"PURSUIT PLA252212 2"1/2"1/2"CHICAGO: WRIST BLADES 1, 2, 9, 10 MEDINABUCKET HANGER FAUCET SPLASH GUARDS FLOOR MOUNTED MOP SINK 27" x 27" x 10"UM.244 2"1/2"1/2"CHICAGO: BRACE & PAIL HOOK 11 ZURNFOR CONNECTION TO GARDEN HOSEHOSE VALVE OUTLET 3/4" NPHS VACUUM BREAKER Z1335 NA NA 3/4" HOSE NA Z1399-VB 6 ZURN-WILKINSDIAL 0-100 PSIPRESSURE GAUGE 2" DIAMETER 92-25 NA NA 1/4" NPT NA NA - ZURNL-1 TAILPIECETRAP PRIMER NA Z1021 NA NA NA NA NA 13 WHA ZURNEXPOSED AFTER RPBAWATER HAMMER ARRESTER 9-1/4" x 1-1/8"1260XL-C NA NA 1/2 NA NA 5 1.ADA INSTALLATION. 2.POINT-OF-USE, HOT WATER SEE WH-1. 3.OPEN FRONT SEAT, SELECTRONIC FLUSH VALVE MODEL 606B-721. 4.REQUIRES FIXTURE CARRIER. 5.EXPOSED LOCATIONS ON SERVICE SIDE, WC-1, 1" FEED LINES TO CS-1 AND CS-5. 6.VACUUM BREAKER, NON-REMOVABLE, BREAKAWAY SCREW. 7.UR-1: SELECTRONIC MODEL 6062.013, 120 VAC. 8.FAUCET 116.101.AB.1, 12 VAC TRANSFORMER. 9.FAUCET 802-VE39VP317ABCP. 10.INSTANT HOT, 120 VAC. 11.FAUCET 897-CP, VACUUM BREAKER SPOUT. 12.NOT USED. 13.TAILPIECE TRAP PRIMER TO EACH FD-1 FLOOR DRAIN. 14.NOT USED. S-2 ELKAYSINGLE BOWL TOP MOUNT SATIN 316L SS SECURITY OFFICE SINK 25" x 22" x 12"PURSUIT PLA252212 2"1/2"1/2"CHICAGO: WRIST BLADES 1, 2, 9 FCV SOLENOID VALVE, FLOOD SENSOR, LEAD-FREE FLOOD CONTROL VALVE 2"NAZURN11" LONG x 21" TALL ZW206 NA NA NA - 1 1/2" 1 1/2" 1 1/2" 1 1/2" HB-2 WALL HYDRANT FOR CONNECTION TO GARDEN HOSE OUTLET 3/4" NPHS VACUUM BREAKER ZURN Z1320XL NA NA 3/4" HOSE NA NA 15 15.AUTOMATIC DRAINING, INTEGRAL BACKFLOW PREVENTER, TYPE 304 STAINLESS STEEL HOUSING. PLUMBING DRAIN SCHEDULE FLOOR DRAIN ITEM DESCRIPTION ROUNDFD-1 ADDITIONAL DESCRIPTION SIZE MANUFACTURER MODEL # 6" STRAINER Z415B WASTE PIPE VENT PIPE 4"2" REMARKS 4, 5, 6 AS NOTED 1.NOT USED. 2.POLISHED STAINLESS STEEL COVER AND SECURING SCREW. 3.NICKEL BRONZE COVER, FLUSH WITH FLOOR. 4.COORDINATE PLACEMENT WITH ARCHITECTURAL SHEETS. 5.STRAINER 1/8 TO 1/4 INCH BELOW FINISHED FLOOR. 6.TRAP PRIMER CONNECTION. 7.NICKEL BRONZE COVER, FLUSH WITH GRADE. 8.VANDAL-PROOF SCREWS. FCO BCO FLOOR CLEANOUT BUILDING CLEANOUT ROUND COVER 2 WAY EXTERIOR COVER 4" PIPE ZURN Z1440 Z1400-B -NA NA4" 3, 4 7, 8 4" PIPEPCOPLUG CLEANOUT BRONZE PLUG -NO COVER Z1446 4"NA AS NOTEDWCOWALL CLEANOUT BRONZE PLUG & COVER Z1446 -NA 2ZURN ZURN ZURN ZURN PLUMBING EQUIPMENT SCHEDULE TAG DESCRIPTION ADDITIONAL DESCRIPTION DIMENSIONS MANUFACTURER (BOD) MODEL NO. (BOD)DCW DHW REMARKS BT120-EWH-01 BT120-EWH-05 BT120-EWH-06 BT120-BFP-01 EEMAXWATER HEATER 9-3/4" x 5-1/4" x 3"SPEX3208 3/8" COMP 3/8" COMP PROADVANTAGEWATER HEATER PA018208T2T 3/4"3/4" INSINKERATORPOINT-OF-USE WATER HEATERWATER HEATER 6" x 5-3/4" x 3-3/4"H-CONTOUR-SS ZURNREDUCED PRESSURE, LEAD-FREE BACKFLOW ASSEMBLY 18" LONG x 6" TALL 975XL2 2 NA POINT-OF-USE WATER HEATER POINT-OF-USE WATER HEATER 15-1/2" x 12-1/2" x 4-1/2" BT120-PRV-01 ZURNTHERMAL EXPANSION RELIEF, LEAD-FREE PRESSURE REDUCER 4.5" LONG x 8" TALL NR3XLEC 2 NA - BT120-BFP-02 ZURNDOUBLE CHECK VALVE, LEAD-FREE DOUBLE CHECK ASSEMBLY 9" LONG x 4" TALL 950XL3 3/4 NA BT120-EWH-02 EEMAXWATER HEATER 9-3/4" x 5-1/4" x 3"SPEX3208 3/8" COMP 3/8" COMP POINT-OF-USE WATER HEATER BT120-EWH-03 BT120-EWH-04 EEMAXWATER HEATER 9-3/4" x 5-1/4" x 3"SPEX3208POINT-OF-USE WATER HEATER EEMAXWATER HEATER 9-3/4" x 5-1/4" x 3"SPEX3208POINT-OF-USE WATER HEATER 3/8" COMP 3/8" COMP 3/8" COMP 3/8" COMP ADA INSTALLATION, SEE ELECT FOR POWER, 208V -1 PH. ADA INSTALLATION, SEE ELECT FOR POWER, 208V -1 PH. ADA INSTALLATION, SEE ELECT FOR POWER, 208V -1 PH. ADA INSTALLATION, SEE ELECT FOR POWER, 208V -1 PH. SEE ELECTRICAL FOR POWER, 208 V -3 PH INSTANT HOT, 120 VAC ORDER WITH FCV - SERVES NON-POTABLE GROUND HYDRANTS. 1/4"NA POWER (KW) 3.0 3.0 3.0 3.0 18.0 0.75 - - - SEE PLANS FOR SIZE MAIN AND ROUTING OF PIPING 18" x 18" x 6" CONCRETE PAD OR AS SPECIFIED INSTALL CAULKING FERRULE AND RAISED HEAD SCREW PLUG IN AREAS WHERE SURFACE IS UNFINISHED. PROVIDE ACCESS HOUSING & COVER IN FINISHED SURFACES SUCH AS FLOORS, SIDEWALKS AND DRIVEWAYS SAME SIZE AS MAIN WITH 4" MAXIMUM 1/8 BEND FITTING AND WYE FITTING OR COMBINATION 1/8 BEND & WYE FITTING. PLUG DRAIN PIPE WHEN CLEANOUT IS LOCATED AT THE BEGINNING OF A RUN 1/4 YARD OF CONCRETE AROUND FITTING FOR ANCHOR FINISHED GRADE FLOW FINISHED FLOOR FLOW FINISHED FLOOR TWO-WAY CLEANOUT FITTING ACCESS HOUSING & COVER SET FLUSH WITH FINISHED SURFACE. INSTALL IN FLOOR, SIDEWALKS AND DRIVES 1/4 YARD OF CONCRETE AROUND FITTING FOR ANCHOR INSTALL CAULKING FERRULE AND RAISED HEAD SCREW PLUG IN AREAS WHERE SURFACE IS UNFINISHED 24" x 18" x 6" CONCRETE PAD OR AS SPECIFIED CAST IRON TO GRADE, SAME SIZE AS MAIN WITH 4" MAXIMUM SEE PLANS FOR SIZE MAIN AND ROUTING OF PIPING FINISHED GRADE FLOW SEE PLANS FOR SIZE MAIN AND ROUTING OF PIPING RISER LENGTH AS REQUIRED LONG SWEEP ELBOW AT BEGINNING OF RUN HUB AT FLOOR FINISHED FLOOR CLEANOUT TEE WITH SCREWED COUNTERSUNK PLUG. TAPERED THREAD WITH TFE JOINT COMPOUND WHERE CLEANOUT TEE IS CONCEALED IN A CHASE OR PARTITION, PROVIDE COVER AS SPECIFIED PIPE MAY EXTEND AS WASTE OR VENT COLUMN OR PARTITION AS SHOWN ON FLOOR PLAN LOCATE CLEANOUT FACE WITHIN 4" OF WALL SURFACE, PROVIDE EXTENSION AS REQUIRED 1. PROVIDE WCO ON SANITARY WASTE BRANCHES NOT SERVED WITH FLOOR CLEANOUT. MAXIMUM HEIGHT ABOVE FINISHED FLOOR 4' -0". 1/8 BEND FITTING AND WYE FITTING OR COMBINATION 1/8 BEND & WYE FITTING NOTES: FINISHED FLOOR FLOOR SINK AND P-TRAP PROVIDE TAIL PIECE TYPE TRAP PRIMERPROVIDE PROTECTIVE SLEEVE AT FLOOR PENETRATION 1/2" TRAP PRIMER LINE ROUTED BELOW FLOOR TO FLOOR DRAIN (NO JOINTS BELOW FLOOR) PDI SIZE "A"INSTALL PER PDI STANDARDS AND MANUFACTURER'S INSTRUCTIONS PROVIDE WATER HAMMER ARRESTERS WITH PISTON AND 0-RING CONSTRUCTION, HAVING PDI #WH-201, ASSE #1010 AND ANSI #A112.26.1M CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL POSITION, BUT NEVER UPSIDE DOWN. INSTALL INLINE WITH WATER FLOW DIRECTION IF POSSIBLE. SIZE UNITS PER TABLES ABOVE. IF BRANCH IS GREATER THAN 20' LONG, PROVIDE ANOTHER WATER HAMMER ARRESTER IN MIDDLE, EACH SIZED FOR HALF THE FIXTURE UNITS -- -- -- HOT OR COLD WATER SUPPLY SINGLE FIXTURE FIXTURE FIXTURE UNIT TABULATION COLD HOT FLUSH VALVE WATER CLOSET URINAL COUNTER SINK LAVATORY MOP BASIN WATER COOLER 10 5 1.5 1.5 2.25 .25 2.25 1.5 1.5 PDI SIZE PIPE SIZE FIXTURE UNIT LOAD A B C D E F 2" 1-1/2" 1 1/4" 1" 3/4" 1/2"1-11 12-32 33-60 61-113 114-154 155-330 3SHOWER3 1/2" COLD WATER SUPPLY WALL MOUNTED LAVATORY OR COUNTERTOP SINK LOOSE-KEY DUAL OUTLET ANGLE VALVE WALL MOUNTED TANKLESS ELECTRIC WATER HEATER COMPRESSION FITTING IN-LINE FLOW CONTROL VALVE C.P. 3/8" HOT WATER SUPPLY TO FIXTURE C.P. 3/8" COLD WATER SUPPLY TO FIXTURE C.P. 3/8" COLD WATER SUPPLY TO WATER HEATER ELECTRIC CONDUIT COMPRESSION FITTING ELECTRICAL DISCONNECTING MEANS -REFER TO ELECTRICAL PLANS FINISHED FLOOR PIPE STANDS AS REQUIRED 2" BALL VALVE (TYPICAL) PIPING SLEEVE THROUGH FLOOR 2" DOMESTIC WATER SERVICE ROUTED BELOW FLOOR FINISHED FLOOR 2" REDUCED PRESSURE BACKFLOW PREVENTER WITH AIR GAP FITTING AND FULL SIZE DRAIN ROUTED TO MOP SINK 2" STRAINER PRESSURE GAUGE (0 -100 PSI) 2" DOMESTIC WATER SUPPLY TO BUILDING PRESSURE REDUCING VALVE PRESSURE GAUGE (0 -100 PSI) 2" FLOOD PROTECTION VALVE JANITOR 203 AIR GAP FITTING AND PIPING DRAINS INTO HUB DRAIN 1" NON-POTABLE WATER 1" DOUBLE CHECK VALVE ASSEMBLY 3' - 0 " MI N I M U M BT120-BFP-02 BT120-BFP-01 BT120-PRV-01 1" NON-POTABLE WATER CAPPED 12" AFF MINUMUM FOR FUTURE USE 1" NON-POTABLE WATER SUPPLY TO CANOPY GROUND HYDRANTS MASONRY WALL SUPPORT CMU WALL METAL WALL SUPPORT SELF- TAPPING SHEET METAL SCREW OFFSET PIPE CLAMP GIRT MASONRY ANCHORS (2) METAL LINER PANEL NOTE: MASONRY ANCHOR SHALL BE EPOXY ADHESIVE TYPE WITH A MINIMUM CAPACITY OF 150 POUND AND SHEAR CAPACITY OF 300 POUND. SUBMIT MANUFACTURER'S DATA FOR APPROVAL WASHINGTON STATE MECHANICAL CODE 2021 (IMC 2021 AMMENDED) AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS (ASHRAE): • ASHRAE 62.1, VENTILATION AND ACCEPTABLE INDOOR AIR QUALITY • ASHRAE 55, THERMAL ENVIRONMENTAL CONDITIONS FOR HUMAN OCCUPANCY WASHINGTON STATE COMMERICAL ENERGY CODE 2021 (IECC 2021 AMMENDED) SMACNA HVAC DUCT CONSTRUCTION STANDARDS COMMERCIAL BUILDING, NEW CONSTRUCTION 2018 WSEC. FOR COMPLIANCE WITH THE WSEC FOR OTHER DISCIPLINES SUCH AS ARCHITECTURAL, ELECTRICAL AND PLUMBING SEE THOSE SHEETS. FOR WSEC COMPLIANCE FOR MECHANICAL – HVAC THE PROJECT MUST MEET THE FOLLOWING: C403 MECHANICAL SYSTEMS AS NOTED BELOW. C403.1.1 HVAC TOTAL SYSTEM PERFORMANCE RATIO (TSPR) THIS PROJECT HAS BUILDINGS IS LESS THAN 5000 SF THEREFORE CLAIMS EXCEPTION 1. THIS PROJECT COMPLIES WITH C403.2.2 VENTILATION AND EXHAUST AND CHAPTER 4 IMC. ASHRAE 62.1 SCHEDULE IS SHOWN IN THIS SET. THIS PROJECT SELECTED EQUIPMENT TO MEET THE MINIMUM EFFICIENCY REQUIREMENTS OF TABLES C403.3.2 (1 THROUGH 12). C403.3.2 (1) AIR COOLED SPLIT SYSTEM AIR CONDITIONER MINIMUM 13.0 SEER: ELECTRICAL ROOM. C403.3.2 (2) AIR COOLED SPLIT SYSTEM HEAT PUMP MIN. 14.0 SEER, 8.2 HSPF: SECURITY, CORE FAC. C403.3.2 (3) SINGLE PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS: STORAGE, TELECOM. THIS PROJECT HAS AN AIR-TO-AIR ENERGY RECOVERY VENTILATION UNIT, COMPLIANT WITH C403.3.5. THIS PROJECT DOES NOT HAVE A REQUIREMENT FOR DIRECT DIGITAL CONTROLS PER C403.4.11. ALL CONTROLS ARE LOCAL WIRED THERMOSTATS. THIS PROJECT TAKES THE ECONOMIZERS EXCEPTION TABLE C403.5 FOR UNITS OF CLIMATE ZONE 4C EFFICIENCY IMPROVEMENT OF 64%. ON SPLIT SYSTEM SERVING THE ELECTRICAL ROOM. C403.6 DOES NOT APPLY. VAV SYSTEMS SERVING MULTIPLE ZONES ARE NOT ON THIS PROJECT. C403.7 THIS PROJECT COMPLIES WITH VENTILATION AND EXHAUST SYSTEMS. IN PARTICULAR THIS PROJECT USES AN OCCUPANCY SENSOR AT THE SECURITY BUILDING AND An ENERGY RECOVERY UNIT FOR VENTILATION NEEDS AT THE CORE FACILITIES BUILDING. SEE ASHRAE 62.1 VENTILATION COMPLIANCE SCHEDULE. C403.7.4.2 THE PROJECT OCCUPANCY SENSOR AT SECURITY BUILDING WILL AUTOMATICALLY TURN OFF THE SUPPLY AIR FAN WITHIN 30 MINUTES OF THE OCCUPANTS LEAVING THE BUILDING. C403.7.8 THE OCCUPANCY SENSOR FAN AT SECURITY BUILDING WILL COMPLY WITH THE REQUIREMENT OF SHUTOFF DAMPERS AND BE CLASS 1 LEAKAGE OF LESS THAN 4 CFM/SF AT 1.0 INCH WATER GAUGE WHEN TESTED IN ACCORDANCE WITH AMCA 500D. C403.8 THIS PROJECT DOES NOT HAVE ANY FAN SYSTEM MOTOR NAMEPLATES EXCEEDING 5 HP. C403.10 CONSTRUCTION OF HVAC SYSTEM ELEMENTS COMPLY WITH THIS SECTION. DUCTS CONVEYING OUTSIDE AIR WILL BE INSULATED TO R-7, PER TABLE C403.10.1.1 OUTDOOR AIR DUCTS INSIDE A CONDITIONED SPACE CRITERIA <2800 CFM WILL BE USED FOR THIS PROJECT. PER C403.10.1.2 ALL OTHER DUCTS SUPPLY, RETURN, EXHAUST DUCTS WILL BE INSULATED USING A DUCT LOCATION AS INSIDE UNCONDITIONED SPACES, R-6. C403.10.2 THIS PROJECT USES LOW PRESSURE DUCT SYSTEMS OPERATING AT < 2 INCHES WATER GAUGE, CONSTRUCTED PER IMC AND THAT WILL BE LONGITUDINAL AND TRANSVERSE JOINTS SEAMS ANS CONNECTIONS SEALED WITH WELDS, GASKETS, MASTICS OR TAPES IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTIONS AND THE SPECIFICATIONS. C403.10.3 PIPING INSULATION WILL BE APPLIED PER TABLE C403.10.3 PER FLUID OPERATING TEMPERATURES, INSULATION CONDUCTIVITY AND NOMINAL PIPE OR TUBE SIZE. C404 NOTES SEE PLUMBING, C405 NOTES SEE ELECTRICAL. C406.1 ADDITIONAL ENERGY EFFICIENCY CREDIT REQUIREMENTS, THIS PROJECT COMPLIES WITH EXCEPTION 1 BY BEING LOW ENERGY SPACES WITH SUFFICIENT PACKAGES FROM TABLE TO ACHIEVE A MINIMUM OF THREE CREDITS. C407 TOTAL BUILDING PERFORMANCE METHOD IS NOT USED ON THIS PROJECT. C408.1 SYSTEM COMMISSIONING, IS NOT REQUIRED PER EXCEPTIONS 1 HVAC AND 2 PLUMBING. C408.2 EXCEPTION 1. TOTAL MECHANICAL SYSTEMS IS LESS THAN 240 MBH COOLING AND LESS THAN 300 MBH HEATING. C408.3 EXCEPTION 2. LARGEST SERVICE WATER HEATING SYSTEM CAPACITY IS LESS THAN 200 MBH. C409 ENERGY METERING AND ENERGY MANAGEMENT. SEE ELECTRICAL, THE HVAC CONTRACTOR WILL NOT BE RESPONSIBLE FOR ANY ENERGY METERING OR ENERGY MANAGEMENT. THIS DESIGN WAS ENGINEERED WITH WSEC CHAPTER 3 CLIMATE ZONE 4 C (MARINE), KING COUNTY, WASHINGTON INTERIOR DESIGN CONDITIONS PER WSEC SECTION C302.1 MAXIMUM OF 72 F FOR HEATING, MINIMUM OF 75 F FOR COOLING EXTERIOR DESIGN CONDITIONS, OUTDOOR DESIGN TEMPERATURES THIS DESIGN WAS ENGINEERED WITH WSEC SECTION 302.2, APPENDIX C TABLE C-1 CONDITIONS. 83 °F DRY BULB OUTDOOR TEMPERATURES: (SEA TAC AIRPORT) 24 °F DRY BULB COOLING SUMMER: HEATING WINTER 65 °F WET BULD NA AHRI AIR-CONDITION, HEATING, AND REFRIGERATION INSTITUTION EER ENERGY EFFICIENCY RATIO HSPF HEATING SEASONAL PERFORMANCE FACTOR MOCP MAXIMUN OVER CURRENT PROTECTION SCCR SHORT CIRCUIT CURRENT RATING M FD T P WALL REGISTER OR GRILLE (SUPPLY) CEILING DIFFUSER OR REGISTER (SUPPLY) CEILING REGISTER OR GRILLE (RETURN AND EXHAUST) WALL REGISTER OR GRILLE (RETURN AND EXHAUST) TURNING VANES 45 DEGREES ENTRY CONICAL TEE BELLMOUTH FIRE DAMPER MANUAL OPPOSED-BLADE DAMPER MANUAL BUTTERFLY DAMPER MOTORIZED DAMPER FLEXIBLE CONNECTION FLEXIBLE DUCTWORK SUPPLY DUCT (SECTION) INTAKE, RETURN, OR EXHAUST DUCT SECTION ROOM TEMPERTURE SENSOR ROOM PRESSURE SENSOR FREE FLOW AREA RECTANGULAR DUCT SIZE 10" OA AIRFLOW TYPE 10" SD-1 (500 OA) DIAMETER NECK SIZE DIFFUSER TYPE, SEE SCHEDULE FOR MODULE SIZE AIRFLOW IN UNITS OF CUBIC FEET PER MINUTE, CFM, TO BE BALANCED TO FREE FLOW AREA RECTANGULAR DUCT SIZE 12"x12" EA AIRFLOW TYPE 16"x8" EG-1 (500 EA) DIAMETER NECK SIZE GRILLE TYPE, SEE SCHEDULE FOR MODULE SIZE AIRFLOW IN UNITS OF CUBIC FEET PER MINUTE, CFM, TO BE BALANCED TO (200)PULLED AIRFLOW, CFM (INCLUDING INFILTRATION) (200) PUSHED AIRFLOW, CFM AIRFLOW TYPES: SA - SUPPLY AIR RA - RETURN AIR OA - OUTSIDE AIR EA - EXHAUST AIR 1. DRAWINGS ARE A GENERAL GRAPHIC SCHEMATIC REPRESENTATION OF THE WORK. FABRICATE AND INSTALL BASED ON ACTUAL FIELD MEASUREMENTS. COORDINATE WITH OTHER TRADES. PROVIDE A COMPLETE SET OF SHOP DRAWINGS REFLECTING ACTUAL DIMENSIONS, ACCESS REQUIREMENTS, AND DETAILS BASED ON THE ACTUAL EQUIPMENT PROCURED. MAINTAIN AN UP TO DATE SET OF AS-BUILTS ON THE JOB SITE. 2. REFER TO SPECIFICATIONS FOR MATERIALS, PRODUCTS AND DIRECTIONS FOR CONSTRUCTION. 3. COORDINATE LOCATION OF ALL PENETRATIONS WITH THE BUILDING STRUCTURE. 4. REFER TO ARCHITECTURE FOR PENETRATION DETAILS THROUGH BUILDING ENVELOPE. 5. PERFORM WORK IN ACCORDANCE WITH THE LATEST EDITIONS, REVISIONS, AMENDMENTS, OR SUPPLEMENTS OF APPLICABLE STATUTES, ORDINANCES, CODES, OR REGULATIONS OF FEDERAL, STATE, AND LOCAL AUTHORITIES HAVING JURISDICTION. 6. WHERE APPROVAL CODES HAVE BEEN ESTABLISHED BY OSHA, UNDERWRITERS LABORATORY, AMERICAN COEDS, ANSI, ASME, ASHRAE, ASTM, ARI, NEC, NFPA, SMACNA, OR THE STATE FIRE INSURANCE REGULATORY BODY, FOLLOW THESE STANDARDS WHETHER OR NOT INDICATED ON THE DRAWINGS. 7. COORDINATE WORK WITH ARCHITECTURAL FEATURES AND COORDINATE WORK SUCH THAT THE INTERFERENCES BETWEEN PIPING, DUCTWORK, EQUIPMENT, PLUMBING WORK, ELECTRICAL WORK, AND BUILDING STRUCTURE WILL BE AVOIDED. 8. PROVIDE ALL WIRING AND ELECTRICAL CONTROLS IN ACCORDANCE WITH NFPA 70 (NEC). 9. DO NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES. 10. PAINT ANY ABOVE CEILING ITEMS, WHICH CAN BE SEEN THROUGH AIR SLOTS OR GRILLES, FLAT BLACK. 11. PROVIDE CEILING ACCESS FOR ALL DAMPERS. 12. HANDLE, STORE, AND INSTALL EQUIPMENT ACCORDING TO MANUFACTURER'S INSTRUCTIONS. 13. DUCT AND DUCT HANGERS SHALL ADHERE TO SMACNA HVAC DUCT STANDARDS. DUCT AND PIPE HANGERS AND SUPPORTS IN UNCONDITIONED SPACE OR EXTERIOR TO BUILDING MUST BE GALVANIZED STEEL. 14. PROVIDE DUCT ACCESS PANELS FOR ALL DAMPER ACTUATORS AND MOTORS LOCATED INSIDE DUCT OR FAN HOUSINGS. 15. REFER TO STRUCTURAL DRAWINGS FOR FRAMING REQUIRED AROUND PIPES AND DUCTS PENETRATING ROOFS, WALLS, AND FLOOR. 16. PROVIDE ACCESS AND CLEARANCE FOR MAINTENANCE FOR MECHANICAL EQUIPMENT AND COMPONENTS AS RECOMMENDED BY EQUIPMENT MANUFACTURER AND APPLICABLE CODES 17. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATIONS OF DIFFUSERS, REGISTERS, GRILLES, AND ACCESS PANELS. 18. ALL DUCT DIMENSIONS AS SHOWN ON MECHANICAL DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 19. COORDINATE EQUIPMENT PAD LOCATIONS AND SIZES WITH ACTUAL EQUIPMENT PROCURED. 20. COORDINATE WITH ELECTRICAL AND CONTROLS CONTRACTOR FOR POWER REQUIREMENTS TO ALL MECHANICAL EQUIPMENT PRIOR TO ORDERING ANY EQUIPMENT. 21. SQUARE ELBOWS IN DUCTWORK MUST HAVE TURNING VANES. 22. ALL DUCT AND PIPE TRANSITIONS, TURNS, AND OFFSETS ARE NOT SHOWN. PROVIDE THESE ITEMS AS REQUIRED FOR A COMPLETE SYSTEM. 23. OVERHEAD UTILITIES AND EQUIPMENT WEIGHING 31 LBS OR MORE MUST BE MOUNTED SO THAT THEY RESIST 0.5 TIMES THE COMPONENT WEIGHT IN ANY HORIZONTAL DIRECTION AND 1.5 TIMES COMPONENT WEIGHT IN THE DOWNWARD DIRECTION. THIS MUST BE ACCOMPLISHED BY EITHER RIGID OR FLEXIBLE SYSTEMS. REFER TO SPEC SECTION ON SEISMIC BRACING FOR REQUIREMENTS. 24. DUCTS SHALL BE INSULATED WITH DUCT WRAP PER SPECIFICATIONS AND THE ENERGY CODE. IN ADDITION TO THE OBD AT THE GRILLE. INSTALL A MANUAL BALANCING DAMPER ON EACH SUPPLY BRANCH TO LACATION, TO SECURITY STORAGE AND SECURITY OFFICE INSTALL A MANUAL BALANCING DAMPER ON EXHAUST BRANCH FROM LACATION. THIS IS IN ADDITION TO THE OBD AT THE GRILLE. 25. HVAC TEMPERATURE SET POINTS, DEAD BANDS, AND SCHEDULES SHALL BE SET PER 2021 WASHINGTON STATE ENERGY CODE (IECC 2021 AMMENDED). 26. CONTRACTORS ARE FREE TO USE ANY PRODUCT WHICH MEETS THE GOVERNMENT'S MINIMUM REQUIREMENTS AND NOT IN CONFLICT WITH OTHER CONTRACT PROVISIONS. UNLESS INDICATED OTHERWISE ON THE PLANS OR SPECIFICATIONS (E.G. SOLE-SOURCE), ALL LISTED MANUFACTURERS ARE THE BASIS OF DESIGN. FOR THESE BASIS OF DESIGN PRODUCTS, OTHER MANUFACTURERS MAY BE SUBSTITUTED AS LONG AS THE STANDARD OF QUALITY AND CHARACTERISTICS OF THE SUBSTITUTED MANUFACTURER MEET OR EXCEED THE STANDARD OF QUALITY AND CHARACTERISTICS OF THE BASIS OF DESIGN. 27. REFER TO GEN-GZN006 AND GEN-GZN007 FOR ADDITIONAL SYMBOLS AND LEGENDS. 28. FOR MINIMUM OUTSIDE AIR AND EXHAUST REQUIREMENTS SEE VENTILATION SCHEDULE (BASED ON RATES FROM 2021 WASHINGTON STATE MECHANICAL CODE). ACCESS HATCH ALLOWS FOR ADJUSTMENT OF EG-2 AND FOR GENERAL INSPECTION OF OPEN AREA ABOVE COMFORT STATIONS. OPEN AREA OVER COMFORT STATIONS IS ALSO OPEN TO JANITORS AND LACATION ROOMS. FIELD ROUTE INTO ARCHITECTURAL HORIZONTAL DUCT CHASE OR SOFFIT TO CROSSOVER TO SECURITY OFFICE. FIELD ROUTE THE SUPPLY AIR DOWN AND OVER THE DOOR. OD D O ODODODOD OO O O 2.72.32.1 2.H 2.112.102.92.82.62.52.4 2.F 2.C 2.2 BT120-THRM-02 BT120-THRM-04 BT120-THRM-36 BT120-THRM-16 BT120-THRM-26 BT120-THRM-46 BT120-THRM-56 ELECTRICAL BT120L1209 TELECOM BT120L1208 OPERATOR RESTROOM BT120L1207 OPERATOR RESTROOM BT120L1206 OPERATOR RESTROOM BT120L1205 OPERATOR RESTROOM BT120L1204 LACTATION ROOM BT120L1202 JANITOR BT120L1203 SEC STORAGE BT120L1201 SECURITY BLDG BT120L1200 BT120-THRM-03 T BT120-THRM-01 STORAGE 1 BT120L1210 BT120-THRM-11 BT120-THRM-07 BT120-THRM-12 BT120-HTR-01 T T T TTT T T T T T T BT120-THRM-05 BT120-ACU-56BT120-ACU-26 BT120-ACU-36 BT120-ACU-46 ACCESS HATCH 18x12 TO ACU-02 TO ACU-03 TO ACU-04 TO ACU-01 TO ACU-05 TO ACU-07 BT120-ACU-16 N D O P 2.72.32.1 2.H 2.112.102.92.82.62.52.4 2.F 2.C 2.C 2.2 BT120-ACU-03 ELECTRICAL BT120L1209 TELECOM BT120L1208 OPERATOR RESTROOM BT120L1207 OPERATOR RESTROOM BT120L1206 OPERATOR RESTROOM BT120L1205 OPERATOR RESTROOM BT120L1204 LACTATION ROOM BT120L1202 JANITOR BT120L1203 SEC STORAGE BT120L1201 STORAGE 1 BT120L1210 LVR-02 BT120-ERU-01 BT120-HTR-01 BT120-ACU-04 LVR-01 8"⌀EA 6"x6" EG-1 (100 EA) TYP 4 10"⌀12"⌀OA BT120-ACU-07 BT120-ACU-05BT120-ACU-01 6"x6" OA 6"x6" SG-1 (50 OA) 6"x6" SG-1 (100 OA) 8"⌀OA 6"x6" SG-1 (100 OA) 10"⌀EA BOA 9'-7" 8"x8" EA 8"⌀OA BOD 11'-2" 6"x6" SG-1 (50 OA) 6"⌀OA 12"x12" EA LOW BOD 10"-10" 12"x12" OA HIGH 8"x8" EG-1 (150 EA) 6"x6" SG-2 (75 OA) 12"x12" OA BOD 12"-7" 4"⌀OA 6"x6" SG-1 (25 OA) 6"⌀OA BOD 13'-2" 6"x6" SG-2 (75 OA) SECURITY BLDG BT120L1200 6"x6" SG-1 (25 OA) TYP 4 12"x12" EA HIGH 12"x12" OA LOW 6"x6" EG-2 (50 EA) 6"⌀EA BT120-HPMP-01 BT120-HPMP-02 BT120-HPMP-03 BT120-HPMP-04 BT120-HPMP-05 BT120-HPMP-06 BT120-ACU-02 BT120-HPMP-07 BT120-HTR-02 8"⌀OA BOD 9'-7" 8"⌀OA BOD 11'-2" BT120-ACU-56 6" ⌀OA BOD 11"-6" N SG SE C S T O R A G E SE C U R I T Y B L D G OP E R A T O R R E S T R O O M SG EG SG EG SG EG SG EG SG INSULATED DUCTWORK OA EA EA OA BT120-ERU-01 INDOOR UNIT INDOOR UNIT INDOOR UNIT INDOOR UNIT INDOOR UNIT T OUTDOOR UNIT PO W E R A N D S I G N A L W I R E S TO A L L I N D O O R U N I T S T T T T OUTDOOR UNIT PO W E R A N D S I G N A L W I R E S RE F R I G E R A N T L I N E S INDOOR UNIT T SIDE VIEW OF A HEATER POWER 3 PORT BRANCH UNIT WITH POWER SEE EQUIPMENT SCHEDULE 3 PORT BRANCH UNIT WITH POWER SEE EQUIPMENT SCHEDULE REFNET JOINT POWER COORDINATE WITH PLUMBING CONDENSATE DRIPS INTO HUB DRAIN OR APPROVED LOCATION, TYPICAL COORDINATE WITH PLUMBING CONDENSATE DRIPS INTO HUB DRAIN OR APPROVED LOCATION, TYPICAL WALL MOUNTED UNIT EG SG LA C T A T I O N R O O M JA N I T O R EG SG SEE PLAN SHEET FOR GRID TAGGING AND CFM BT120-ACU-16 BT120-ACU-26 BT120-ACU-36 BT120-ACU-46 BT120-ACU-56 BT120-THRM-56BT120-THRM-46BT120-THRM-36BT120-THRM-26BT120-THRM-16 TYPICAL BRANCH REFRIGERANT LINES GAS = 3/8 INCH LIQUID = 1/4 INCH EXTERIOR WALL FINISHED FLOOR SURFACE MOUNTED BOTTOM, 7 FT AFF BT120-HTR-02 BT120-HTR-01 FRONT VIEW OF A HEATER BT120-THRM-12 BT120-THRM-11 UNIT MOUNTED T- STAT. EXPECT SHIPPED LOOSE BT120-HPMP-06 MAIN REFRIGERANT LINES GAS = 3/4 INCH LIQUID = 3/8 INCH (5 SETS SEE PLAN SHEET FOR TAGGING) SE E S P L I T S Y S T E M S S C H E D U L E FO R P I P E S I Z E S TE L E C O M SG ST O R A G E 1 SG OUTSIDE AIR LOUVER SCALE: NTS CORE FACILITY AIRFLOW DIAGRAM 1 SCALE: NTS ELECTRIC HEATERS 2 SCALE: NTS SINGLE ZONE SPLIT SCHEMATIC 4 SCALE: NTS 5 ZONE HEAT PUMP CORE FACILITY SCHEMATIC 3 CS LVR-02 EXHAUST AIR LOUVER LVR-01 --- - FILTER TYP 2 OP E R A T O R R E S T R O O M OP E R A T O R R E S T R O O M OP E R A T O R R E S T R O O M EL E C T R I C A L R O O M SG BMS POINTS LIST HEAT PUMP EQUIPMENT TYPE PLC INPUT / OUTPUT DESCRIPTION X INDICATE/ ALARM SYSTEM EQUIPMENT ID SERVING AREA HVAC ELECTRICAL HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC HVAC HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP HEAT PUMP HEATER HEATER VENTILATOR VENTILATOR VENTILATOR UTILITY LIGHTING LIGHTING LIGHTING ELECTRICAL ROOM BUS BAY CHARGING YARD GENERATOR GENERATOR GENERATOR ELECTRICAL ELECTRICAL ELECTRICAL BT120-ACU-01 BT120-ACU-02, 03 BT120-ACU-04, 05 BT120-ACU-16 BT120-ACU-26 BT120-ACU-36 BT120-ACU-46 BT120-ACU-56 BT120-ACU-07 BT120-HTR-01 BT120-HTR-02 BT120-ERU-01 BT120-ERU-01 BT120-ERU-01 ROOM TEMPERATURE SENSOR MONITOR AIRFLOW RANGE ROOM TEMPERATURE SENSOR ROOM TEMPERATURE SENSOR ROOM TEMPERATURE SENSOR ROOM TEMPERATURE SENSOR ROOM TEMPERATURE SENSOR ROOM TEMPERATURE SENSOR ROOM TEMPERATURE SENSOR ROOM TEMPERATURE SENSOR ROOM TEMPERATURE SENSOR ROOM TEMPERATURE SENSOR DIRTY FILTER LOADING ALARM FAN PROVING ALARM POINT TYPE ANALOG INPUT ANALOG INPUT ANALOG INPUT ANALOG INPUT ANALOG INPUT ANALOG INPUT ANALOG INPUT ANALOG INPUT ANALOG INPUT ANALOG INPUT DIGITAL INPUT DIGITAL INPUT PLC TAG BMS CONTROL OUT PUT NOTES TEMPERATURE MONITOR ROOM, DOES INTERFACE WITH EQUIPMENT ANALOG INPUT ANALOG INPUT X X TEMPERATURE MONITOR ROOM, DOES INTERFACE WITH EQUIPMENT TEMPERATURE MONITOR ROOM, DOES INTERFACE WITH EQUIPMENT X TEMPERATURE MONITOR ROOM, DOES INTERFACE WITH EQUIPMENT X TEMPERATURE MONITOR ROOM, DOES INTERFACE WITH EQUIPMENT X TEMPERATURE MONITOR ROOM, DOES INTERFACE WITH EQUIPMENT X TEMPERATURE MONITOR ROOM, DOES INTERFACE WITH EQUIPMENT X TEMPERATURE MONITOR ROOM, DOES INTERFACE WITH EQUIPMENT X TEMPERATURE MONITOR ROOM, DOES INTERFACE WITH EQUIPMENT X TEMPERATURE MONITOR ROOM, DOES INTERFACE WITH EQUIPMENT X TEMPERATURE MONITOR ROOM, DOES INTERFACE WITH EQUIPMENT X X X ALARMS WHEN ONBOARD BMS CARD INDICATES AIRFLOW OUT OF RANGE ALARMS WHEN ONBOARD BMS CARD INDICATES FANS DID NOT PROVE ALARMS WHEN ONBOARD BMS CARD INDICATES DIRTY FILTER MONITOR VOLTAGE AND FREQUENCY MONITOR VOLTAGE AND FREQUENCY COMMON WARNING ITEMS COMMON SHUTDOWN ITEMS LIGHTING CONTROL PANEL LIGHTING CONTROL PANEL LIGHTING CONTROL PANEL ANALOG INPUT ANALOG INPUT DIGITAL INPUT DIGITAL INPUT TBD TBD TBD X X X X X X X ALARMS IF VOLTAGE OR FREQUENCY IS OUT OF RANGE ALARMS IF VOLTAGE OR FREQUENCY IS OUT OF RANGE ALARMS IF COMMON WARNINGS ARE INDICATED ALARMS IF UNWANTED SHUTDOWN OCCURS MONITOR LIGHTING CONTROL PANEL MONITOR LIGHTING CONTROL PANEL MONITOR LIGHTING CONTROL PANEL GENERAL NOTES: 1. SEE DWG BT120-MHS005 - MHS007 AND MHS010 COMMUNICATION SET FOR BMS CONTROLLER DETAILS, CABLES AND TAGS LOCATION. 2. SEE THE CONTROLS NETWORK DIAGRAM BT120-MHS006 FOR SENSOR AND DEVICE CONNECTIONS. ADD POINTS OR DEVICES AS REQUIRED FOR A COMPLETE SYSTEM. PSC HMI ACU PQMGEN LCPLCP CUATSUPS LCP ACU ACU ACU ACU ACUACU ACU ACU ACU ACU ACU ACU ACU ACU ERU ACU LEVEL 1 BACNET MS/TP LEVEL 1 NOTES: 1. ONLY A REPRESENTATIVE SAMPLE OF CONTROLLERS ARE SHOWN. COMPLETE SYSTEM ARCHITECTURE TO BE PROVIDED BY CONTROLS CONTRACTOR. 2. ALL EQUIPMENT BY CONTROLS CONTRACTOR, UNLESS NOTED OTHERWISE. 3. NETWORK CONFIGURATION SHALL CONFORM WITH ALL PERFORMANCE REQUIREMENTS IN SECTION 25 10 00. 4. PROVIDE LOCKABLE ENCLOSURES FOR ALL PSCs, SCs AND NETWORK EQUIPMENT. 5. ALL BMS EQUIPMENT, CONTROLLERS AND NETWORK EQUIPMENT SHALL BE POWERED FROM 120VAC POWER CIRCUITS. COORDINATE POWER REQUIREMENTS AND FINAL LOCATIONS WITH DIVSION 26. 6. CONFIRM ALL BMS PANEL LOCATIONS WITH CLIENT PRIOR TO INSTALLATION. 7. 24VAC POWER TRUNK WIRING AND STEP-DOWN TRANSFORMERS PROVIDED BY CONTROLS CONTRACTOR, AND SHALL BE POWERED FROM 120VAC POWER CIRCUITS. 8. INTEGRATE TO 3RD PARTY SYSTEM CONTROLLER VIA BACNET OR MODBUS COMMUNICATION, COORDINATE REQUIREMENTS WITH EQUIPMENT VENDOR. 9. CONTROLLER PROVIDED BY MANUFACTURER, CONTROLS CONTRACTOR SHALL INTERGRATE TO THIS EQUIPMENT. 10. CONTROLS CONTRACTOR SHALL INTEGRATE TO ELECTRICAL EQUIPMENT PROVIDED BY DIVISION 26. REFER TO ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR QUANTITIES AND LOCATIONS. 11. CONTROLS CONTRACTOR SHALL INTEGRATE WITH LIGHTING CONTROL SYSTEM. REFER TO ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR QUANTITIES AND LOCATIONS OF LIGHTING CONTROL PANELS. MULTIZONE SPLIT SYSTEM MASTER CONTROLLER BT105-ACU-16 SPLIT SYSTEM CONTROLS (NOTE 9) ELECTRICAL EQUIPMENT (NOTE 10) BT105-SWGR-01BT105-GEN-01 120VAC BY DIV. 26 DATA CONNECTION TO BUILDING IT NETWORK KN TO DIV 25 SPEC BT105-BMS-01 CAT-6 LIGHTING CONTROLLERS (NOTE 11) BT105-LCP-02BT105-LCP-01 BACNET IP MULTIZONE SPLIT SYSTEM INTERCONNECTS, COORDINATE WIRING REQUIREMENTS WITH MANUFACTURER. LOCATED IN TELECOM ROOM BT120L1208 BT105-HPMP-06 AIR COOLED CONDENSING UNITS (NOTE 9) IP CONNECTION TO BUILDING IT NETWORK. BY DIV. 27. BT120-ATS-01 BT105-UPS-01 IP CONNECTION TO BUILDING IT NETWORK. BY DIV. 27. CAT-6 ELECTRICAL EQUIPMENT, NOTE 10 BT105-LCP-03 BT105-ACU-26 BT105-ACU-36 BT105-ACU-46 BT105-ACU-56 MODBUS RTU HVAC SYSTEM MONITORING (NOTE 9) BT105-ACU-02BT105-ACU-01 BT105-ACU-03 BT105-ACU-04 BT105-ACU-05 BT105-ACU-16 BT105-ACU-26 BT105-ACU-36 BT105-ACU-46 BT105-ACU-56 BT105-ERU-01 BT105-ACU-07 BMS POINTS LIST EQUIPMENT TYPE BMS I/O DESCRIPTION INDICATE/ ALARM SYSTEM EQUIPMENT ID POINT TYPE BMS CONTROL OUTPUT NOTES GENERAL NOTES: 1. SEE DWG BT120-MHS005 - MHS007 AND MHS010 COMMUNICATION SET FOR BMS CONTROLLER DETAILS, CABLES AND TAGS LOCATION. 2. SEE THE CONTROLS NETWORK DIAGRAM BT120-MHS006 FOR SENSOR AND DEVICE CONNECTIONS. ADD POINTS OR DEVICES AS REQUIRED FOR A COMPLETE SYSTEM. HVAC DUCTLESS SPLIT SYSTEM BT120-ACU-01 BMS INTERFACE AV/DV X X HVAC DUCTLESS SPLIT SYSTEM BT120-ACU-02 BMS INTERFACE AV/DV X X HVAC DUCTLESS SPLIT SYSTEM BT120-ACU-03 BMS INTERFACE AV/DV X X HVAC DUCTLESS SPLIT SYSTEM BT120-ACU-04 BMS INTERFACE AV/DV X X HVAC DUCTLESS SPLIT SYSTEM BT120-ACU-05 BMS INTERFACE AV/DV X X HVAC DUCTLESS SPLIT SYSTEM BT120-ACU-07 BMS INTERFACE AV/DV X X HVAC DUCTLESS SPLIT SYSTEM BT120-ACU-16 BMS INTERFACE AV/DV X X HVAC DUCTLESS SPLIT SYSTEM BT120-ACU-26 BMS INTERFACE AV/DV X X HVAC DUCTLESS SPLIT SYSTEM BT120-ACU-36 BMS INTERFACE AV/DV X X HVAC DUCTLESS SPLIT SYSTEM BT120-ACU-46 BMS INTERFACE AV/DV X X HVAC DUCTLESS SPLIT SYSTEM BT120-ACU-56 BMS INTERFACE AV/DV X X INTEGRATE ALL AVAILABLE POINTS AND HAVE THEM AVAILABLE FOR MONITORING ON THE OPERATOR WORKSTATION. CONTROLS SHALL BE THROUGH THE MANUFACTURER'S FACTORY CONTROLLER. CONTROLLER SHALL HAVE AN ADAPTER TO COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. REFER TO SEQUENCE OF OPERATION AND MANUFACTURER INSTRUCTIONS FOR MORE INFORMATION. XHVAC ENERGY RECOVERY UNIT BT120-ERU-01 STATUS DI HVAC ENERGY RECOVERY UNIT BT120-ERU-01 SUPPLY FILTER PRESSURE DROP AI X HVAC ENERGY RECOVERY UNIT BT120-ERU-01 RETURN FILTER PRESSURE DROP AI X HVAC OCCUPIED MODE BT120-BMS-01 OCCUPIED MODE DO X HVAC UNOCCUPIED OVERRIDE BT120-BMS-01 UNOCCUPIED OVERRIDE DI X NOTES: AI = ANALOG INPUT, AO = ANALOG OUTPUT, DI = DIGITAL INPUT, DO - DIGITAL OUTPUT. AV = ANALOG POINT THOUGH BACNET INTERFACE / PACKAGED CONTROLLER. DV = DIGITAL POINT THROUGH BACNET INTERFACE / PACKAGED CONTROLLER. INTEGRATE ALL AVAILABLE POINTS AND HAVE THEM AVAILABLE FOR MONITORING ON THE OPERATOR WORKSTATION. CONTROLS SHALL BE THROUGH THE MANUFACTURER'S FACTORY CONTROLLER. CONTROLLER SHALL HAVE AN ADAPTER TO COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. REFER TO SEQUENCE OF OPERATION AND MANUFACTURER INSTRUCTIONS FOR MORE INFORMATION. INTEGRATE ALL AVAILABLE POINTS AND HAVE THEM AVAILABLE FOR MONITORING ON THE OPERATOR WORKSTATION. CONTROLS SHALL BE THROUGH THE MANUFACTURER'S FACTORY CONTROLLER. CONTROLLER SHALL HAVE AN ADAPTER TO COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. REFER TO SEQUENCE OF OPERATION AND MANUFACTURER INSTRUCTIONS FOR MORE INFORMATION. INTEGRATE ALL AVAILABLE POINTS AND HAVE THEM AVAILABLE FOR MONITORING ON THE OPERATOR WORKSTATION. CONTROLS SHALL BE THROUGH THE MANUFACTURER'S FACTORY CONTROLLER. CONTROLLER SHALL HAVE AN ADAPTER TO COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. REFER TO SEQUENCE OF OPERATION AND MANUFACTURER INSTRUCTIONS FOR MORE INFORMATION. INTEGRATE ALL AVAILABLE POINTS AND HAVE THEM AVAILABLE FOR MONITORING ON THE OPERATOR WORKSTATION. CONTROLS SHALL BE THROUGH THE MANUFACTURER'S FACTORY CONTROLLER. CONTROLLER SHALL HAVE AN ADAPTER TO COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. REFER TO SEQUENCE OF OPERATION AND MANUFACTURER INSTRUCTIONS FOR MORE INFORMATION. INTEGRATE ALL AVAILABLE POINTS AND HAVE THEM AVAILABLE FOR MONITORING ON THE OPERATOR WORKSTATION. CONTROLS SHALL BE THROUGH THE MANUFACTURER'S FACTORY CONTROLLER. CONTROLLER SHALL HAVE AN ADAPTER TO COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. REFER TO SEQUENCE OF OPERATION AND MANUFACTURER INSTRUCTIONS FOR MORE INFORMATION. INTEGRATE ALL AVAILABLE POINTS AND HAVE THEM AVAILABLE FOR MONITORING ON THE OPERATOR WORKSTATION. CONTROLS SHALL BE THROUGH THE MANUFACTURER'S FACTORY CONTROLLER. CONTROLLER SHALL HAVE AN ADAPTER TO COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. REFER TO SEQUENCE OF OPERATION AND MANUFACTURER INSTRUCTIONS FOR MORE INFORMATION. INTEGRATE ALL AVAILABLE POINTS AND HAVE THEM AVAILABLE FOR MONITORING ON THE OPERATOR WORKSTATION. CONTROLS SHALL BE THROUGH THE MANUFACTURER'S FACTORY CONTROLLER. CONTROLLER SHALL HAVE AN ADAPTER TO COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. REFER TO SEQUENCE OF OPERATION AND MANUFACTURER INSTRUCTIONS FOR MORE INFORMATION. INTEGRATE ALL AVAILABLE POINTS AND HAVE THEM AVAILABLE FOR MONITORING ON THE OPERATOR WORKSTATION. CONTROLS SHALL BE THROUGH THE MANUFACTURER'S FACTORY CONTROLLER. CONTROLLER SHALL HAVE AN ADAPTER TO COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. REFER TO SEQUENCE OF OPERATION AND MANUFACTURER INSTRUCTIONS FOR MORE INFORMATION. INTEGRATE ALL AVAILABLE POINTS AND HAVE THEM AVAILABLE FOR MONITORING ON THE OPERATOR WORKSTATION. CONTROLS SHALL BE THROUGH THE MANUFACTURER'S FACTORY CONTROLLER. CONTROLLER SHALL HAVE AN ADAPTER TO COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. REFER TO SEQUENCE OF OPERATION AND MANUFACTURER INSTRUCTIONS FOR MORE INFORMATION. INTEGRATE ALL AVAILABLE POINTS AND HAVE THEM AVAILABLE FOR MONITORING ON THE OPERATOR WORKSTATION. CONTROLS SHALL BE THROUGH THE MANUFACTURER'S FACTORY CONTROLLER. CONTROLLER SHALL HAVE AN ADAPTER TO COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. REFER TO SEQUENCE OF OPERATION AND MANUFACTURER INSTRUCTIONS FOR MORE INFORMATION. BMS POINTS LIST EQUIPMENT TYPE BMS I/O DESCRIPTION INDICATE/ ALARM SYSTEM EQUIPMENT ID POINT TYPE BMS CONTROL OUTPUT NOTES ELECTRICAL LIGHTING CONTROL PANEL BT105-LCP-01 STATUS DV X ELECTRICAL LIGHTING CONTROL PANEL BT105-LCP-01 SCHEDULE AV X ELECTRICAL LIGHTING CONTROL PANEL BT105-LCP-02 STATUS DV X ELECTRICAL LIGHTING CONTROL PANEL BT105-LCP-02 SCHEDULE AV X ELECTRICAL LIGHTING CONTROL PANEL BT105-LCP-03 STATUS DV X ELECTRICAL LIGHTING CONTROL PANEL BT105-LCP-03 SCHEDULE AV X NOTES: AI = ANALOG INPUT, AO = ANALOG OUTPUT, DI = DIGITAL INPUT, DO - DIGITAL OUTPUT. AV = ANALOG POINT THOUGH BACNET INTERFACE / PACKAGED CONTROLLER. DV = DIGITAL POINT THROUGH BACNET INTERFACE / PACKAGED CONTROLLER. ELECTRICAL UPS BT105-UPS-01 BMS INTERFACE AV/DV X ELECTRICAL UPS BT105-UPS-01 STATUS DV X ELECTRICAL UPS BT105-UPS-01 GENERAL ALARM DV X ELECTRICAL ATS BT105-ATS-01 BMS INTERFACE AV/DV X ELECTRICAL ATS BT105-ATS-01 ATS-UTILITY POSITION DV X ELECTRICAL ATS BT105-ATS-01 UTILITY POWER AVAILABLE AV X THE PACKAGED LIGHTING CONTROL PANEL SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS FOR EACH LIGHTING CIRCUIT/ZONE ON THE LIGHTING CONTROL PANEL. THE PACKAGED LIGHTING CONTROL PANEL SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS FOR EACH LIGHTING CIRCUIT/ZONE ON THE LIGHTING CONTROL PANEL. THE PACKAGED LIGHTING CONTROL PANEL SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS FOR EACH LIGHTING CIRCUIT/ZONE ON THE LIGHTING CONTROL PANEL. THE PACKAGED LIGHTING CONTROL PANEL SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS FOR EACH LIGHTING CIRCUIT/ZONE ON THE LIGHTING CONTROL PANEL. THE PACKAGED LIGHTING CONTROL PANEL SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS FOR EACH LIGHTING CIRCUIT/ZONE ON THE LIGHTING CONTROL PANEL. THE PACKAGED LIGHTING CONTROL PANEL SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS FOR EACH LIGHTING CIRCUIT/ZONE ON THE LIGHTING CONTROL PANEL. THE PACKAGED CONTROLLER SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS. THE PACKAGED CONTROLLER SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS. THE PACKAGED CONTROLLER SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS. ELECTRICAL ATS BT105-ATS-01 STANDBY POWER AVAILABLE AV X ELECTRICAL ATS BT105-ATS-01 ATS-STANDBY POSITION DV X ELECTRICAL ATS BT105-ATS-01 ATS FAIL DV X THE PACKAGED ATS CONTROLLER SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS AT A MINIMUM. THE PACKAGED ATS CONTROLLER SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS AT A MINIMUM. THE PACKAGED ATS CONTROLLER SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS AT A MINIMUM. THE PACKAGED ATS CONTROLLER SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS AT A MINIMUM. THE PACKAGED ATS CONTROLLER SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS AT A MINIMUM. THE PACKAGED ATS CONTROLLER SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS AT A MINIMUM. ELECTRICAL POWER QUALITY METER BT105-SWGR-01 BMS INTERFACE AV/DV X THE PACKAGED CONTROLLER SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS. ELECTRICAL GENERATOR BT105-GEN-01 BMS INTERFACE AV/DV X THE PACKAGED CONTROLLER SHALL COMMUNICATE WITH THE BMS THROUGH THE BACNET INTERFACE. THE BMS SHALL MONITOR THESE POINTS. GENERAL NOTES: 1. SEE DWG BT120-MHS005 - MHS007 AND MHS010 COMMUNICATION SET FOR BMS CONTROLLER DETAILS, CABLES AND TAGS LOCATION. 2. SEE THE CONTROLS NETWORK DIAGRAM BT120-MHS006 FOR SENSOR AND DEVICE CONNECTIONS. ADD POINTS OR DEVICES AS REQUIRED FOR A COMPLETE SYSTEM. LENGTH EQUALS DIAMETER OF DUCT RIGID/FLEXIBLE ROUND DUCTWORK RECTANGULAR DUCTWORK 1. DO NOT USE POWDER POWERED FASTENING SYSTEMS TO ATTACH SUPPORTS TO STRUCTURE. 2. SUPPORT SYSTEM MUST NOT DAMAGE DUCT, INSULATION, OR CAUSE DUCT SHAPE DEFORMATION. 3. HANGER SIZES SHALL BE IN ACCORDANCE WITH SMACNA, LATEST EDITION. 4. THE USE OF PLUMBING STRAP OR NYLON/PLASTIC STRAP FOR DUCT OR EQUIPMENT SUPPORT IS PROHIBITED. STAINLESS STEEL SHEET METAL SADDLE ATTACH TO STRUCTURE PER SMACNA RECOMMENDATIONS 1/2" MINIMUM BAND CLAMP ATTACH TO STRUCTURE WITH BEAM CLAMPS AS DETAILED NUT WITH LOCK WASHER 1-1/2" GALVANIZED STEEL HANGER WITH ALL-THREAD ROD IN TRAPEZE CONFIGURATION ALL-THREAD ROD NOTES: 18 GA GALVANIZED STEEL DRAINABLE FIXED BLADE LOUVER, SEE LOUVER SCHEDULE ALUMINUM BIRD SCREEN ACROSS OPENING SEAL PERIMETER JOINT WATER-TIGHT EXTERIOR WALL - VERIFY CONSTRUCTION MATERIAL AND COORDINATE OPENING REQUIREMENTS FULL-SIZE SHEET METAL PLENUM FABRICATE SHEET METAL PLENUM-TO-DUCT TRANSITION. DUCT SIZE AS INDICATED ON DRAWINGS ROUND OR RECTANGULAR DUCT WORK AS INDICATED ON DRAWINGS. SUPPORT FROM STRUCTURE ABOVE 1. MAXIMUM ALLOWABLE SUPPORTED LOAD PER HANGER: TYPE A : 600 LBS TYPE D : 600 LBS TYPE B : 250 LBS TYPE E : 150 LBS TYPE C : 300 LBS TYPE C - METAL BUILDING PURLIN TYPE E - WOODTYPE D - STEEL BEAM METAL ROOF THREADED SIDE BEAM BRACKET WOOD RAFTER OR TRUSS CHORD (2) 1/4" x 1 1/2" WOOD SCREWS CEILING PLATE WITH THREADED ROD COUPLER 3/8" DIA THREADED ROD, SEE NOTE 1 METAL BUILDING PURLIN 3/8" DIA THREADED ROD, SEE NOTE 1 BEAM CLAMP RETAINING STRAP STEEL BEAM BEAM CLAMP 3/8" DIA THREADED ROD, SEE NOTE 1 GYP BOARD OR PLYWOOD CEILING 1/4" DIA TEK SCREWS, MIN 2 PER BRACKET NOTES: RECTANGULAR DUCT SQUARE ELBOW RECTANGULAR DUCT RADIUSED ELBOW RECTANGULAR DUCT TAKE-OFF ROUND DUCT TAKE-OFF FROM RECTANGULAR DUCT DUCT OFFSET DUCT SIZE TRANSITION W W W W L 12" MINIMUM 45° MAXIMUM A NOTES: 45° EXPANDED THROAT 1.5 W1.5 WTURNING VANES GORED ELBOWS ARE NOT ALLOWED. L = 1/4 W, 4" MIN TAKE OFF TO BE AN EXPANDED CONICAL, BELLMOUTH FLANGED TYPE FITTING. NO BUTT TAP TYPE FITTINGS WILL BE ALLOWED. AN EXPANDED CONICAL TAP MAY BE SUBSTITUTED FOR ANGLED TAKEOFFS ON LOW PRESSURE SYSTEM. DO NOT USE FLEX DUCT FOR OFFSETS. DIMENSION "A" TO BE A MAXIMUM OF 22.5° FOR DIVERGING AND 30° FOR CONVERGING AIR FLOWS. THIS APPLIES FOR BOTH ROUND AND RECTANGULAR DUCTWORK INCLUDING SQUARE TO ROUND TRANSITIONS. PROVIDE TURNING VANES ON ALL RECTANGULAR SUPPLY DUCTWORK. UNLESS NOTED OTHERWISE DO NOT INSTALL TURNING VANES IN RETURN OR EXHAUST AIR DUCT. TURNING VANES TO BE DOUBLE WIDTH VANES OR SINGLE WIDTH VANES WITH 3/4" TRAILING EDGE. ROUND DUCT RADIUSED ELBOW ROUND DUCT TAKE-OFF FROM ROUND DUCT 1. THE USE OF PLUMBING STRAP OR NYLON/PLASTIC STRAP FOR DUCT OR EQUIPMENT SUPPORT IS PROHIBITED. 2. MAXIMUM FLEX DUCT LENGTH IS 3'. INTERIOR WALL, SEE FLOOR PLAN INDOOR UNIT (ACU) OVERHEAD, SEE SCHEDULE PROVIDE WALL SLEEVES FOR PIPING INSULATED 3/4" CONDENSATE DRAIN LINE, ROUTE TO DRAIN AS INDICATED ON DRAWINGS EXTERIOR WALL, SEE FLOOR PLAN POWER AND CONTROL WIRING TO INDOOR UNIT INSULATED REFRIGERANT LINES. SECURE TO WALL PER MANUFACTURER'S REQUIREMENTS. PROVIDE SHROUD WHERE INDICATED ON SCHEDULE OUTDOOR UNIT (HPMP), SEE SCHEDULE. PROVIDE MANUFACTURER'S REQUIRED CLEARANCE FOR VENTILATION. SEE STRUCTURAL DWG FOR MOUNTING DETAIL. PROVIDE FOR WIRED THERMOSTAT UNLESS SCHEDULED AS REMOTE CONTROL SA INSTALL ON WALL AT 96" FROM FLOOR TO BOTTOM OF UNIT (UNLESS NOTED OTHERWISE) SEQUENCE OF OPERATION SETPOINT TEMPERATURE: COOLING: CONTINUOUS 78° F HEATING: OCCUPIED 68° F RUN MODE: 1. EVAPORATOR RUN SHALL RUN CONTINUOUSLY. 2. UNITS SHALL CYCLE HEATING OR COOLING SECTION OFF/ON AS REQUIRED TO MAINTAIN ROOM SETPOINT. AIRFLOW ATS P P G G MOTOR CONNECTION; MOTOR HORSEPOWER AS SHOWN FUSED SAFETY SWITCH, 100 AMP SWITCH, 80 AMP FUSES NON-FUSED SAFETY SWITCH COMBINATION MOTOR STARTER DISCONNECT SWITCH LOCAL CONTROLLER CONTROL PANEL FLOOR OR SURFACE MOUNTED 208V PANELBOARD FLOOR OR SURFACE MOUNTED 480V PANELBOARD RECESSED 208V PANELBOARD RECESSED 480V PANELBOARD GENERAL PURPOSE, DRY TYPE TRANSFORMER. 'T75' IS THE KVA RATING FOR THE TRANSFORMER. IN THIS EXAMPLE, 'T75' REPRESENTS A TRANSFORMER RATED 75KVA. CONNECTION POINT TO EQUIPMENT SPECIFIED IN OTHER DIVISIONS. RACEWAY, CONDUCTOR, TERMINATION AND CONNECTION IN THIS DIVISION. CTL JUNCTION BOX WITH COVER PLATEJB WALL MOUNTED JUNCTION BOX WITH COVER PLATEJB AUTOMATIC TRANSFER SWITCH. SPD SURGE PROTECTIVE DEVICE ELECTRICAL HANDHOLE OR VAULT ELECTRIC SYMBOLS POWER DISTRIBUTION / EQUIPMENT LEGEND GROUND ROD GROUND ROD WITH TEST WELL GROUND CONNECTION GROUND CONDUCTOR TAP GROUNDING CONDUCTOR G G 3 aA1E DENOTES POLE MOUNTED SINGLE ARM LUMINAIRE. POLE HEIGHT AS INDICATED. DENOTES POLE MOUNTED TWIN CONFIGURATION SINGLE ARM LUMINAIRE. INDIVIDUAL LUMINAIRE TYPE AS INDICATED; POLE HEIGHT AS INDICATED. DENOTES POLE MOUNTED TRIPLEX CONFIGURED SINGLE ARM LUMINAIRE. INDIVIDUAL TYPE AS INDICATED; POLE HEIGHT AS INDICATED. DENOTES POLE MOUNTED QUADRAPLEX CONFIGURED SINGLE ARM LUMINAIRE. INDIVIDUAL LUMINAIRE TYPE AS INDICATED; POLE HEIGHT AS INDICATED. PENDANT OR CEILING MOUNTED ILLUMINATED EGRESS EXIT SIGN. WHERE USED, DIRECTIONAL ARROWS AS INDICATED. MOUNT 8'-0" ABOVE FINISHED FLOOR, UNLESS INDICATED OTHERWISE. NUMERAL = CIRCUIT NUMBER. ONLY WHEN THE OUTLINE AREA OF THE CIRCUIT IS PROVIDED. OTHERWISE PANEL NUMBER WILL BE INCLUDED WITH CIRCUIT NUMBER. LOWERCASE ALPHANUMERIC CHARACTER = LIGHTING SWITCH OR CONTROL ZONE LIGHTING TYPE TAG -COORDINATE WITH LIGHTING FIXTURE SCHEDULE WALL MOUNTED ILLUMINATED EGRESS EXIT SIGN. WHERE USED, DIRECTIONAL ARROWS AS INDICATED. MOUNTED 8'-0" AFF UNLESS INDICATED OTHERWISE . LUMINAIRE, SEE SCHEDULE FOR LIGHTING TYPE LUMINAIRE CONNECTED TO EMERGENCY SOURCE, SEE SCHEDULE FOR TYPE 3 THREE WAY. 4 FOUR WAY. XP EXPLOSION PROOF K KEYED SWITCH WP WEATHERPROOF. M SURFACE MOUNTED MOTOR RATED WITH OVERLOAD ELEMENTS, CONTINOUS CURRENT RATING AND QUANTITY OF POLES AS REQUIRED FOR EQUIPMENT SERVED. D WALL DIMMER. OS OCCUPANCY SENSOR [WITH MANUAL OVERRIDE]. 3a LOWERCASE LETTER(S) = CONTROL ZONE CAPITAL LETTER(S) AND/OR NUMERAL = SPECIAL DESIGNATOR SUBSCRIPT DEFINED ABOVE LIGHTING CONTROL DEVICE IDENTIFICATION (TYPICAL FOR ALL LIGHTING CONTROL DEVICE SYMBOLS WHERE USED) MD MULT-LOCATION DIMMER, NUMERALS AS INDICATED FOR SINGLE LOCATION DIMMER. VS VACANCY SENSOR/SWITCH CEILING MOUNTED PASSIVE INFRARED OCCUPANCY SENSOR D P CEILING MOUNTED DUAL-TECHNOLOGY VACANCY SENSOR CEILING MOUNTED DAYLIGHT SENSOR CEILING MOUNTED PHOTO SENSOR 3K THREE WAY KEYED SWITCH. 4K FOUR WAY KEYED SWITCH. DP DOUBLE POLE. VD VACANCY SENSOR/DIMMER O OCCUPANCY SENSOR/SWITCH OD OCCUPANCY SENSOR/DIMMER V V V O O O CEILING MOUNTED DUAL-TECHNOLOGY OCCUPANCY SENSOR CEILING MOUNTED DUAL-TECHNOLOGY CORRIDOR OCCUPANCY SENSOR O O CEILING MOUNTED PASSIVE INFRARED CORRIDOR OCCUPANCY SENSOR CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR O CEILING MOUNTED ULTRASONIC CORRIDOR OCCUPANCY SENSOR CEILING MOUNTED PASSIVE INFRARED VACANCY SENSOR CEILING MOUNTED ULTRASONIC VACANCY SENSOR RECESSED WALL MOUNTED SWITCH. INSTALL ADJACENT DEVICES UNDER COMMON FACEPLATE, FOUR DEVICES MAXIMUM PER FACEPLATE. EVENLY DIVIDE DEVICES INTO SEPARATE GROUPS WHERE ADJCENT DEVICES EXCEEDS FOUR. SURFACE WALL MOUNTED SWITCH.INSTALL ADJACENT DEVICES UNDER COMMON FACEPLATE, FOUR DEVICES MAXIMUM PER FACEPLATE. EVENLY DIVIDE DEVICES INTO SEPARATE GROUPS WHERE ADJCENT DEVICES EXCEEDS FOUR. BRANCH CIRCUIT "HOMERUN", TIC MARKS INDICATE NUMBER OF CONDUCTORS (INCLUDING NEUTRAL). #10 INDICATES AWG WIRE SIZE, AND 3/4" INDICATES CONDUIT SIZE. WIRE AND CONDUIT SIZE IS APPLICABLE TO EACH CIRCUIT INDICATED FOR ENTIRE LENGTH OF CIRCUIT. ALL BRANCH CIRCUIT WIRING SHALL INCLUDE A #12 AWG GROUND IN 3/4" CONDUIT. ARROW HEADS DENOTE A HOMERUN TO PANELBOARD. NUMBER OF ARROWHEADS INDICATE NUMBER OF CIRCUITS IN CONDUIT. "LP-1,3" INDICATES PANEL AND CIRCUIT NUMBERS. SINGLE CONDUIT CAPPED3 MULTIPLE CONDUITS, ALL INDIVIDUALLY CAPPED. WHERE NUMERIC DESIGNATION INDICATED, DENOTES QUANTITY OF CAPPED CONDUITS. IN THIS EXAMPLE, THREE CAPPED CONDUITS RACEWAY CONTINUATION CONDUIT OR CABLE TURNING UP OR TOWARD THE OBSERVER CONDUIT OR CABLE TURNING DOWN OR AWAY FROM THE OBSERVER CONDUIT OR CABLE CHANGE IN ELEVATION CABLE TRAY OR CONDUIT RACK CONDUIT WITH BUSHING A R1 SWITCH LEG CONNECTED TO SWITCH "A" SWITCH LEG CONNECTED TO RELAY #1 IN LIGHTING CONTROL PANEL INDICATED. DUPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE, RECEPTACLES ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R. 13 ONE OR TWO NUMERIC DIGIT BRANCH CIRCUIT NUMBER (13 IN THIS EXAMPLE) WP WEATHER-RESISTANT, WEATHERPROOF WITH HINGED COVER GFCI GFCI TYPE, WIRED FOR GFCI TRIP FOR DESIGNATED RECEPTACLE ONLY (NON-FEED-THRU INSTALLATION) TWO DUPLEX (QUAD) RECEPTACLES. UNLESS INDICATED OTHERWISE, RECEPTACES ARE FLUSH MOUNTED, 20A, 125V, 1PH, 2P, 3W, NEMA 5-20R. SIMPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE, RECEPTACLES ARE FLUSH MOUNTED, 20A,125V,1PH, 2P, 3W, NEMA 5-20R. SPECIAL PURPOSE RECEPTACLE, UNLESS INDICATED OTHERWISE, RECEPTACLES ARE FLUSH MOUNTED. RECEPTACLE NEMA TYPES INDICATED ON THE SPECIAL RECEPTACLE SCHEDULE. WP-WIN WEATHER-RESISTANT TYPE, WEATHERPROOF WITH WHILE-IN-USE COVER TR TAMPER RESISTANT TYPE RECEPTACLE SPD SURGE PROTECTIVE DEVICE TYPE RECEPTACLE FLUSH FLOOR TYPE FLOOR BOX. INSTALL PER MANUFACTURER INSTRUCTION. FLUSH FLOOR TYPE POKE-THRU WITH DUPLEX RECEPTACLE. INSTALL PER MANUFACTURER INSTRUCTION. POWER POLE WITH DUPLEX RECEPTACLES, LENGTH AS REQUIRED TO EXTEND ABOVE CEILING; SHADED AREA DENOTES TELECOMMUNICATION RACEWAY. CEILING MOUNTED DUPLEX RCPT. UNLESS INDICATED OTHERWISE, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R F IN WALL FURNITURE CONNECTION. INSTALL PER MFR INSTRUCTION. NUMERAL = CIRCUIT NUMBER1 GFCIWP CAPITAL LETTER(S) = SPECIAL DESIGNATOR SUBSCRIPT DEFINED ABOVE PR PROJECTOR RECEPTACLE TO BE LOCATED WITHIN PROJECTOR OR CEILING MOUNT DUPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE, RECEPTACLES ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R, MOUNTED 6" ABOVE COUNTERTOP OR BACKSPLASH UNLESS OTHERWISE NOTED. DUPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE, RECEPTACLES ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R ON AN EMERGENCY CIRCUIT. +48"DENOTES THE MOUNTING HEIGHT IN INCHES ABOVE THE FINISHED FLOOR. +36"+(INCHES) = HEIGHT IN INCHES ABOVE FINISHED FLOOR U USB CHARGING R WHEN USED ON DEMOLITION PLANS: DEMOLISH DEVICE AND FACEPLATE, OUTLET BOX TO REMAIN. WHEN USE ON NEW WORK PLANS: INSTALL DEVICE IN EXISTING OUTLET BOX. FLUSH FLOOR TYPE FLOOR BOX. INSTALL PER MANUFACTURER INSTRUCTION. RECEPTACLE NEMA TYPES INDICATED ON THE SPECIAL RECEPTACLE SCHEDULE. FLUSH FLOOR TYPE POKE-THRU WITH SPECIAL RECEPTACLE. INSTALL PER MANUFACTURER INSTRUCTION. RECEPTACLE NEMA TYPES INDICATED ON THE SPECIAL RECEPTACLE SCHEDULE. POWER POLE WITH DUPLEX RECEPTACLES, LENGTH AS REQUIRED TO EXTEND ABOVE CEILING; SHADED AREA DENOTES TELECOMMUNICATION RACEWAY. RECEPTACLE NEMA TYPES INDICATED ON THE SPECIAL RECEPTACLE SCHEDULE. ON POWER AND LIGHTING SHEETS, ALL DEVICES IN THE OUTLINED AREA ARE CIRCUITED TO THE SPECIFED PANEL UNLESS OTHERWISE NOTED. SURFACE MOUNTED RECEPTACLE WIRING SYSTEM/RACEWAY/CABLE TRAY LEGEND ELECTRICAL IDENTIFICATION NUMBERING LUMINAIRE LEGEND LIGHTING CONTROL DEVICE LEGEND GROUNDING AND LIGHTNING PROTECTION LEGEND WIRING DEVICE LEGEND 'LXX'-'YYYY'-'ZZ'(EXAMPLE) YYYY = EQUIPMENT CODE -REPRESENTS A SPECIFIC KIND OF EQUIPMENT, COMPONENT, OR FACILITY. ZZ = INSTANCE NUMBER LXX = LOCATION CODE REFER TO "ST EQUIPMENT AND FACILITIES NUMBERING STANDARD' FOR MORE DETAILED EXPLANATION ELECTRICAL EQUIPMENT CODES ('YYYY') ACM ABB CONTROL MODULE ATS AUTOMATIC TRANSFER SWITCH BEB BATTERY ELECTRIC BUS BEBPC BEB PLUG CHARGER BRKR BREAKER CR COMMUNICATION RACK DISC DISCONNECT SWITCH EVLV ELECTRIC VALVE EUH ELECTRICAL UNIT HEATER EWH ELECTRIC WATER HEATER FACP FIRE ALARM CONTROL PANEL FARP FIRE ALARM RELAY PANEL FSD FIRE SMOKE DAMPER GEN GENERATOR GFD GROUND FAULT DETECTOR H TRACTION POWER 1500 V DC BREAKER /SWITCH HH HANDHOLE HHLV LOW VOLTAGE HANDHOLE HHMV MEDIUM VOLTAGE HANDHOLE INV INVERTER K LIGHTING KEY SWITCH LB LOAD BANK LC LIGHTING CABINET LCP LIGHTING CONTROL PANEL MBP MAINTENANCE BYPASS / ISOLATION SWITCH MC MOTOR CONTROLLER MCC MOTOR CONTROL CENTER MCS MOTOR CONTROL SWITCH MDF MAIN DISTIBUTION FRAME MH MANHOLE MPC MINI POWER CENTER MS MANUAL MOTOR STARTER MTR METER NRVEV NRV EV CHARGER OS OCCUPANCY SENSOR PB2 PANELBOARD -208/120 V PB4 PANELBOARD -480/277 V PBLV LOW VOLTAGE PULLBOX PBMV MEDIUM VOLTAGE PULLBOX PC BUS PLUG COLUMN PE POLYETHYLENE RD ROLL-UP DOOR SWBD SWITCHBOARD SWGR SWITCHGEAR T TRANSFORMER UPS UNINTERRUPTIBLE POWER SUPPLY VFD VARIABLE SPEED/FREQ DRIVE O3 THREE WAY OCCUPANCY SENSOR GFCI DUPLEX RECEPTACLE. UNLESS INDICATED OTHERWISE, RECEPTACLES ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R. DUPLEX CONTROL RECEPTACLE. UNLESS INDICATED OTHERWISE, RECEPTACLES ARE FLUSH MOUNTED, 20A,125V, 1PH, 2P, 3W, NEMA 5-20R. T75 100AS 80AF DAYLIGHT ZONES BTM01-PB2-105 GROUND BUS BAR CEILING MOUNTED WATTSTOPPER LMRC-211/212 ROOM CONTROLLERRC OR OVERRIDE SWITCH OUTDOOR WALL MOUNTED LUMINAIRE CAN LUMINAIRE, SEE SCHEDULE FOR LIGHTING TYPE OUTDOOR CANOPY LUMINAIRE 'E' DESIGNATION -LIGHTING FIXTURE WITH EMERGENCY SOURCE GENERAL LEGEND NOTE ** REFER TO GEN-GZN006 & GEN-GZN007 FOR ADDITIONAL SYMBOLS AND LEGEND. TVM TICKET VENDING MACHINE ELECTRICAL HANDHOLE OR VAULT WITH DECORATIVE LID ELECTRIC SYMBOLS MEDIUM VOLTAGE DRAWOUT CIRCUIT BREAKER. L LONG PICKUP AND TIME DELAY PROTECTION PROTECTIONDESIGNATION S SHORT PICKUP AND TIME DELAY PROTECTION I INSTANTANEOUS PICKUP PROTECTION G GROUND (EARTH) PICKUP AND TIME DELAY PROTECTION N NEUTRAL PROTECTION LSIG250 AF 225 AT LOW VOLTAGE MOLDED CASE CIRCUIT BREAKER. KEY INTERLOCK PROTECTION DEVICE FEATURES / ACCESSORIESDESIGNATION NOTE: MULTIPLE DESIGNATIONS MAY BE ADJACENT TO DEVICE. K ST SHUNT TRIP ET ELECTRONIC TRIP LSIG 1200/5 3 SOLID STATE TRIP UNIT WITH CT INPUT OR MODULE CAPABLE OF MONITORING AMPS, INSTANTANEOUS KW, PEAK KW AND KWH. TRANSFORMER. PHASE CURRENT TRANSFORMER. 100 VA POTENTIAL TRANSFORMER. CONTROL POWER TRANSFORMER.FUSE SURGE PROTECTIVE DEVICE. NON-FUSED DISCONNECT / SAFETY SWITCH. 60A/3P IN THIS EXAMPLE. DENOTES 60 AMPERES / 3 POLE. F-30A IN THIS EXAMPLE, DENOTES FUSED WITH 30 AMPERE FUSES. F-MFR DENOTES FUSE RATING IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS FOR THE UTILIZATION EQUIPMENT PROTECTED BY THE FUSES. N3R IN THIS EXAMPLE, DENOTES NEMA 3R ENCLOSURE. SN DENOTES SOLID NEUTRAL. N.C. 30A/3P N.C. 30A/3P F-30A FUSED DISCONNECT / SAFETY SWITCH. MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'FVNR' DENOTES FULL VOLTAGE NON-REVERSING, WHERE INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. N.C.DENOTES NORMALLY CLOSED. N.O.DENOTES NORMALLY OPEN. T-PD2A 30KVA 480 V-208/120 V E FVNR1 E FVR1 MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'FVR' DENOTES FULL VOLTAGE REVERSING, WHERE INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, 'VFD' DENOTES VARIABLE OR ADJUSTABLE FREQUENCY DRIVE. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'RVAT' DENOTES REDUCED VOLTAGE AUTOTRANSFORMER, WHERE INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. E RVAT1 E RVPW1 MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'RVPW' DENOTES REDUCED VOLTAGE PART-WINDING, WHERE INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. E RVSS1 MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'RVSS' DENOTES REDUCED VOLTAGE SOLID STATE SOFT STARTER, WHERE INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. WD1 MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'WD' DENOTES WYE-DELTA STARTER, WHERE INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. 521200A 3 MR 1200/5 ZERO SEQUENCE CURRENT TRANSFORMER. 1 50/5 MSCT1 MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'MSCT' DENOTES MULTI-SPEED CONSTANT TORQUE STARTER, WHERE INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. MSVT1 MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'MSVT' DENOTES MULTI-SPEED VARIABLE TORQUE STARTER, WHERE INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. MSCH1 MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, 'MSCH' DENOTES MULTI-SPEED CONSTANT HORSEPOWER STARTER, WHERE INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. MOTOR; EQUIPMENT IDENTIFICATION AND HORSEPOWER AS INDICATED. ELECTRONIC METERING MODULE: MICROPROCESSOR BASED FOR METERING, ANALYZING, WAVEFORM CAPTURE AND CAPABLE OF PROVIDING MONITORED DATA PARAMETERS LMU LOCAL MONITORING UNIT FOR SWITCHGEAR ASSEMBLIES CAPABLE OF UP TO 40 SEPARATE DATA INPUTS FROM BREAKER LSIG'S, EMM'S AND MFR'S; CONFIGURABLE DISPLAY SCREEN; DATA OUTPUT PORTS CPT480V 10KVA, 1PH 120/240V PT 200 KVAR VARIABLE POWER FACTOR CORRECTION CAPACITOR BANK. E 2 SPD1 MOTOR CONTROL CENTER MOTOR STARTER OR LOCAL CONTROLLER. IN THIS EXAMPLE, '1' DENOTES NEMA SIZE, '2 SPD' DENOTES TWO SPEED FULL VOLTAGE NON-REVERSING, WHERE INDICATED, 'E' DENOTES ELECTRONIC OR SOLID STATE OVERLOAD RELAY. UNLESS INDICATED OTHERWISE, LOCAL CONTROLLER ENCLOSURES ARE RATED NEMA 1. SPD N.C. 600 A LOAD INTERRUPTER SWITCH. EMM 50 EF-01 VFD M MULTIFUNCTION METER KT30Y 480 V-208/120 V ISOLATION TRANSFORMER. CABLE LUG TERMINATION LA'S 3 LIGHTNING ARRESTER. NUMERIC VALUE DENOTES QUANTITY. L ATS P S TRANSFER SWITCH. 'ATS' DENOTES AUTOMATIC TRANSFER TYPE, 'MTS' DENOTES MANUAL TRANSFER TYPE. 'P' DENOTES PRIMARY POWER SOURCE; 'S' DENOTES SECONDARY POWER SOURCE; 'L' DENOTES TRANSFER SWITCH LOAD SIDE CONNECTION POINT. DENOTES ELECTRICAL CONDUIT E ENGINE. G GENERATOR. GFP GROUND FAULT PROTECTION. LOADBANK. FUSED DRAWOUT POTENTIAL TRANSFORMER. FUSED POTENTIAL TRANSFORMER. POWER FILTER. SURGE PROTECTIVE DEVICE. R1 RELAY. UPS AND BATTERY. LSIG 1600 AF 800 AT N.C. 30A/3P (3) F-30A DEVICE ADJUSTABLE PROTECTION OPTIONS. LONG, SHORT, INSTANTANEOUS, AND GROUND PICKUPS IN THIS EXAMPLE. "AF" DENOTES FRAME SIZE, "AT" DENOTES TRIP SETTING. 1600A FRAME WITH 800A TRIP IN THIS EXAMPLE. DENOTES SWITCH SIZE AND POLES. 30A, 3-POLE SWITCH IN THIS EXAMPLE. DENOTES QUANTITY AND RATING OF FUSES. THREE 30A IN THIS EXAMPLE. DENOTES ORIENTATION OF SWITCH. NORMALLY CLOSED IN THIS EXAMPLE. PNL L1A PNL L1A PANELBOARD WITH A VOLTAGE OF 480V OR HIGHER. PANELBOARD WITH VOLTAGE UNDER 480V. BATTERY. DIGITAL METER.DM GROUNDING CONNECTION. FEEDER / BRANCH CIRCUIT DESIGNATION. IN THIS EXAMPLE, '13Y' REFERS TO THE SYMBOL COLUMN OF THE FEEDER/BRANCH CIRCUIT SCHEDULE. THE ASSOCIATED SYMBOL DESIGNATION DENOTES THE FEEDER / BRANCH CIRCUIT REQUIREMENTS FOR THE ITEM TAGGED. 13Y SINGLE LINE DIAGRAM LEGEND SINGLE LINE DIAGRAM LEGEND SINGLE LINE DIAGRAM LEGEND ADJUSTABLE PROTECTION DESIGNATIONS KIRK-KEY INTERLOCK.K SITE POWER DISTRIBUTION PAD MOUNTED EQUIPMENT AS IDENTITIFED E E E E ELECTRICAL DUCTBANK SL SL SITE LIGHTING DPM DIGITAL POWER METER G STANDBY GENERATOR RATING SHOWN (KW/KVA) 500/625 SURGE PROTECTIVE DEVICE.SPD 100:5 CURRENT TRANSFORMER RATING AS SHOWN VT POTENTIAL TRANSFORMER X MPR: MAIN PROTECTIVE RELAY FPR: FEEDER PROTECTIVE RELAY ** REFER TO GEN-GZN006 & GEN-GZN007 FOR ADDITIONAL SYMBOLS AND LEGEND. SINGLE LINE DIAGRAM LEGEND GENERAL LEGEND NOTE ELECTRIC SYMBOLS GENERAL NOTES MOUNTING HEIGHT SCHEDULE 1. WHERE "SPLIT CIRCUIT" IS INDICATED, EXTEND SPLIT CIRCUIT HOME RUNS TO A COMMON JUNCTION BOX ABOVE THE PANEL INDICATED. TIE HOME RUNS TOGETHER USING SPLICE KIT AND EXTEND A SINGLE SET OF CONDUCTORS TO CIRCUIT BREAKER NUMBER INDICATED. WIRING USED IN SPLIT CIRCUITS SHALL BE THE SAME SIZE. 2. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND INDICATE THE GENERAL LOCATION OF OUTLETS, EQUIPMENT, AND THE CIRCUIT ARRANGEMENT OF THE REQUIRED WIRING. ALTHOUGH THE DRAWINGS DO NOT NECESSARILY INDICATE THE ACTUAL ROUTES OF SURFACE MOUNTED CONDUITS, WHERE INDICATED, THEY SHALL BE FOLLOWED AS CLOSELY AS PROPER COORDINATION WITH THE WORK OF OTHER TRADES AND SPACE WILL PERMIT. WHERE CONDUIT RUNS ARE NOT SHOWN ON THE DRAWINGS, SUCH AS FOR MECHANICAL EQUIPMENT, COORDINATE CONDUIT RUNS WITH THE WORK OF OTHER TRADES AND STRUCTURE. SIMPLIFY INSTALLATION WHEREVER POSSIBLE, BUT SUBJECT TO APPROVAL BY THE COR FOR VISUAL AND STRUCTURAL REASONS. IT IS NOT WITHIN THE SCOPE OF THE DRAWINGS TO SHOW ALL NECESSARY OFFSETS, BENDS, PULL BOXES, AND OBSTRUCTIONS. THE DRAWINGS ARE NOT INTENDED TO BE SCALED, REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS. 3. NOT ALL SYMBOLS SHOWN IN LEGENDS ARE USED -SEE DRAWINGS FOR APPLICABLE DEVICES. 4. MOUNTING HEIGHTS INDICATED AS '+##' ARE MEASURED FROM FINISHED FLOOR UNLESS OTHERWISE NOTED. 5. PROVIDE LABELS DENOTING EQUIPMENT SERVED AND CORRESPONDING CIRCUIT NUMBER ON DEDICATED RECEPTACLES. 6. SEAL PENETRATIONS OF FIRE-AND/OR SMOKE-RATED CONSTRUCTION WITH U.L. APPROVED STOPPING MATERIAL TO RESTORE THE ORIGINAL RATING OF THE PENETRATED CONSTRUCTION. 7. SEAL PENETRATIONS OF NON-RATED PARTITIONS WITH APPROVED MATERIAL TO PREVENT AIRFLOW AND DEBRIS. 8. MOUNTING HEIGHTS SHOWN ON ELECTRICAL, COMMUNICATIONS, AND SYSTEMS DRAWINGS ARE FOR BIDDING PURPOSES ONLY. REFER TO INTERIOR ELEVATION DRAWINGS FOR MOUNTING HEIGHTS OF DEVICES AND EQUIPMENT. WHERE DISCREPANCIES OCCUR, INTERIOR ELEVATIONS TAKE PRECEDENCE. 9. SUPPORT BOXES AND CONDUIT ABOVE CEILING INDEPENDENTLY. DO NOT SUPPORT FROM SUSPENDED CEILING SYSTEM. 10. WHERE CONCEALED BY INACCESSIBLE FINISHES, PROVIDE ACCESS DOORS FOR JUNCTION & PULL BOXES, CONTROL DEVICES & EQUIPMENT, DISCONNECT SWITCHES, AND OTHER ITEMS REQUIRING SERVICE, MAINTENANCE, OPERATION, OR ADJUSTMENT. SIZE AND LOCATE ACCESS DOORS FOR EASE OF PERFORMANCE OF THE FUNCTION INTENDED. DOORS SHALL NOT BE SMALLER THAN 18" x 18". COORDINATE LOCATION OF ACCESS DOORS WITH AFFECTED TRADES. SUBMIT PANEL LOCATIONS FOR APPROVAL BY THE ARCHITECT PRIOR TO INSTALLATION. 11. INSTALL ADJACENT DEVICES UNDER A COMMON FACEPLATE, WITH NO MORE THAN FOUR DEVICES IN A SINGLE FACEPLATE. WHERE MORE THAN FOUR ADJACENT DEVICES ARE PRESENT, EVENLY DIVIDE DEVICES INTO SEPARATE GROUPS OF NO LESS THAN TWO DEVICES PER GROUP. PROVIDE BARRIERS WITHIN BOXES TO SEPARATE DEVICES WHERE DIFFERENT CIRCUITS AND DIFFERENT VOLTAGES ARE PRESENT. 12. PROVIDE LUGS AS NECESSARY FOR TERMINATING OVERSIZED CONDUCTORS OR OTHERWISE MAKE PROVISIONS FOR TERMINATING OVERSIZED CONDUCTORS IN DEVICES WHOSE LUGS DO NOT ACCEPT THE OVERSIZED CONDUCTOR SIZE. 13. SHARED NEUTRAL CONDUCTORS ARE PROHIBITED. 14. ALL OUTAGES MUST BE SCHEDULED WITH A MINIMUM OF 21 CALENDAR DAYS IN ADVANCE. NOTIFY SOUND TRANSIT PERSONNEL (CONTRACTING OFFICER). MAKE AN APPLICATION FOR OUTAGES TO SOUND TRANSIT HIGH VOLTAGE FACILITY DEPARTMENT WITH THE PROVIDED REQUEST FORMS AND SUBMIT FOR APPROVAL FOR THE OUTAGES. NO OUTAGES WILL TAKE PLACE WITHOUT WRITTEN AUTHORIZATION TO SOUND TRANSIT PERSONNEL BY THE CONTRACTOR. OUTAGES CAN BE CANCELED BY SOUND TRANSIT UP UNTIL THE SCHEDULED TIME OF THE OUTAGE. OUTAGES SHALL BE COORDINATED WITH SOUND TRANSIT PERSONNEL (CONTRACTING OFFICER) TO MINIMIZE TOTAL OUTAGES TO THE FACILITY. 15. ADJUST WIRE SIZES TO COMPENSATE FOR VOLTAGE DROP. THE LENGTH OF A SINGLE PHASE 20A CIRCUIT (ONE-WAY) SHALL NOT EXCEED THE FOLLOWING VALUES (BASED ON 16A LOAD): CONDUCTOR SIZE (AWG) MAXIMUM 120V CIRCUIT LENGTH MAXIMUM 277V CIRCUIT LENGTH #12 #10 #8 #6 60'-0" 90'-0" 140'-0" 225'-0" 135'-0" 210'-0" 330'-0" 525'-0" DEVICES/EQUIPMENT MOUNTING HEIGHT (AFF)MEASURED TO: RECEPTACLES AS INDICATED ON LEGEND/PLANS GROUND FAULT CIRCUIT INTERRUPTER TOGGLE SWITCHES GROUND BUS BARS WALL DIMMERS 4'-0" INTEGRATED COMMUNICATIONS PANELS MANUAL MOTOR STARTERS CENTER GENERATOR REMOTE ALARM ANNUNCIATOR OCCUPANCY SENSORS -WALL MOUNTED GENERATOR TERMINAL BLOCKS LIGHTING CONTROL PANEL BAS TERMINAL BLOCKS LIGHTING CONTROL STATION GENERATOR STOP SWITCH JUNCTION BOXES GENERATOR TANK FUEL LEVEL INDICATORS MONITORING/CONTROL PANEL UPS REMOTE MONITORING PANEL SURFACE METAL RACEWAYS UPS BATTERY MONITORING / CONTROL PANEL PANELBOARDS MAIN SWITCHGEAR BATTERY CHARGER DISCONNECT SWITCHES RELAY CONTROL PANELS AUTOMATIC TRANSFER SWITCHES MANUAL TRANSFER SWITCHES CONTROL STATIONS TVSS (NON-INTEGRAL) MAGNETIC MOTOR CONTROLLERS LIGHTING CONTACTORS ENCLOSURES INDIVIDUAL CKT BREAKERS ENCLOSURES EMERGENCY POWER OFF SWITCHES TIME SWITCHES TELECOMMUNICATIONS OUTLETS TELECOMMUNICATIONS OUTLETS -OVER COUNTER MOUNTING HEIGHT SCHEDULE NOTES: 1. USE ABOVE INDICATED MOUNTING HEIGHTS UNLESS INDICATED OTHER WISE ON DRAWINGS OR SPECIFICATIONS. 2. COORDINATE MOUNTING HEIGHTS WITH FIELD CONDITIONS, OTHER TRADES, AND RELATED EQUIPMENT. 3. REDUCE MOUNTING HEIGHTS OF FIRE ALARM VISUAL AND AUDIO/VISUAL ALARMS WHERE REQUIRED TO MAINTAIN 6" MINIMUM SPACING FROM CEILING. TOP 4'-0"TOP 4'-0"TOP 4'-0"TOP 6'-6"TOP 4'-0"CENTER CENTERAS INDICATED ON LEGEND/PLANS TOP TOP TOP TOP TOP TOP TOP TOP TOP TOP TOP AS INDICATED ON LEGEND/PLANS 5'-0" 6'-6" 6'-6" 6'-6" 6'-6" 6'-0" (NTE) 5'-0" 6'-6" 6'-6" 6'-6" 5'-6"CENTER CENTER CENTER (OVER TOP OF COUNTER) CENTER CENTER CENTER TOP TOP TOP TOP TOP TOP TOP TOP TOP TOP 6'-6" 1'-6" 0'-6" 4'-0" 2'-0" 6'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-6" 6'-6" MOUNTING HEIGHT SCHEDULE MAXIMUM 20A CIRCUIT LENGTH SCHEDULE KEY NOTES: E E E E E E FO FO FO FO FO CO CO DET V DETV DETV DETV PTZ DETV PTZ BUS BAY 7 BUS BAY 6 BUS BAY 5 BUS BAY 2 BUS BAY 8 BUS BAY 3 BUS BAY 4 BUS BAY 1 48 48 48 48 48 CO CB1 CB1 CB1L CB1 CB1L CB1 CB1 CB1 CB1 CB1 CB1 CB1L CB1 48 48 CB1 CB 1L CB1L 60 CB1L CB1L CB1 CB1 CB1 CB1L 48 CB1 CB1L CB1 60 48 60 48 CB1 CB1L CB1 CB1 CB1 CB1 CB1 48 CB1 CB1L CB1 CB1L CB1 CB1 60 CB1 CB1 48 48CB1 60 48 CB1 48 CB1 CB1 CB1 CB1 60 CB1 CB1L CB1 CB1 48 CB1 48 CB1 CB 1 L 48 48 BT120-HH-SL-10 BT120-HH-SL-05 BT120-HHLV-28 BT120-HHLV-13 BT120-HHLV-12 BT120-HH-SL-22BT120-HH-SL-21BT120-HH-SL-20BT120-HH-SL-19 BT120-HH-SL-09 BT120-HH-SL-08 BT120-HH-SL-06 BT120-HH-SL-23 BT120-HH-SL-04 BT120-HH-SL-03 BT120-EVCS-01 BT120-PB2-06-1,3,2,4 1 BT120-EPP212 1 BT120-EPP213 1 BT120-EPP214 1 BT120-EPP215 BT120-HH-SL-15 BT120-HH-SL-18 BT120-HH-SL-26 BT120-HH-SL-80 BT120-HH-SL-14 BT120-HH-SL-13 BT120-HH-SL-12 BT120-HH-SL-11 BT120-HH-SL-31 BT120-HH-SL-34 BT120-HH-SL-37 BT120-HH-SL-35 BT120-HH-SL-39 BT120-HH-SL-40 BT120-HH-SL-50 BT120-HH-SL-52 BT120-HH-SL-57 BT120-HH-SL-36 BT120-HH-SL-32 BT120-HH-SL-16 BT120-HH-SL-17 BT120-HH-SL-38 BT120-HH-SL-49 BT120-HH-SL-51 BT120-HH-SL-53 BT120-HH-SL-54 BT120-HH-SL-55 BT120-HH-SL-56 BT120-HH-SL-58 BT120-HH-SL-75 BT120-HH-SL-41 BT120-HH-SL-43 BT120-HH-SL-44 BT120-HH-SL-45 BT120-HH-SL-46 BT120-HH-SL-47 BT120-HH-SL-71 BT120-HH-SL-72 BT120-HH-SL-73 BT120-HH-SL-48 BT120-HH-SL-01 BT120-HH-SL-02 BT120-HH-SL-30 BT120-HH-SL-29 BT120-HH-SL-28 BT120-HH-SL-42 BT120-HH-SL-27 BT120-HH-SL-77 BT120-PB2-03: 23 IRRIGATION PEDESTAL LN-1 5,7 LN-3 5,7LN-1 5,7 LN-1 5,7 LN-1 5,7LN-1 5,7 LN-1 5,7 LN-1 5,7 LN-1 5,7 LN-1 5,7 LN-1 5,7 LN-1 5,7 LN-1 5,7 LN-2 6,8 LN-1 6,8 LN-1 6,8 LN-1 6,8 LN-2 6,8 LN-2 5,7LN-2 5,7 LN-2 6,8 LN-1 10,12 LN-2 10,12 LN-2 10,12 LN-2 10,12 LN-1 10,12 LN-1 10,12 LN-2 9,11 LO 9,11 LO 9,11 LO 9,11 LN-2 10,12 LN-2 10,12 LN-2 1,3LN-1 1,3 LN-1 1,3 LN-2 1,3 LN-1 6,8 LN-2 2,4 LN-2 6,8 LN-2 2,4 LN-2 2,4 LN-2 2,4 LN-2 6,8 LN-2 2,4 LN-2 2,4 LN-2 2,4 LN-2 2,4 LN-1 6,8 LO 6,8 LO 1,3 LN-1 2,4 LN-1 1,3 LN-1 1,3 LO 1,3 LO 1,3 LO 1,3 LO 1,3 LN-2 1,3 LO 2,4 LN-1 1,3 LN-2 1,3 LN-1 1,3 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 122 BT120-HH-SL-07 BT120-HHLV-15 LO 1,3 LO 1,3 BT120-GEN-01 BT120-HH-SL-74 TYP 132 BT120-HH-SL-76 BT120-HH-SL-79 LN-1 1,3 BT120-N2-205 BT120-N2-209 BT120-N2-208 BT120-N2-204 BT120-N2-207 BT120-N2-211 BT120-HHLV-14 BT120-N2-210 BT120-N4-203 BT120-E4-204 BT120-HH-SL-33 BT120-N2-203 BT120-N2-212 BT120-N2-214 BT120-N2-213 140 140 140 140 142 143 BT120-HH-SL-24 BT120-HH-SL-25 J02 EXISTING VAULT TO REMAIN (1) 4"C BT120-HHSC-25 BT120-HHLV-27 BT120-HHLV-26 BT120-N4-201C,D 141 BT120-N4-204A,B BT120-HHLV-29 BT120-N2-206 NEW TRANSFORMER VAULT PER PSE CUSTOMER DRAWING. 4"C, 2/0 SVC CABLE INSTALLED BY CONTRACTOR, CONNECTIONS BY PSE. BT120-HH-SL-82 LN-2 2,4 LN-2 1,3 BT120-HH-SL-83 147 1 313 1 1 LN-2 6,8 LN-1 10,12 1 1 BT120-HH-SL-86 BT120-HH-SL-85 LN-1 1,3 BT120-HH-SL-78 1482 149149 2 149(TYP) PV1 PV3 PV2 (1)4"C 2 KEY NOTES: GENERAL NOTES: 1. SEE SHEET BT120-EPS121 FOR SITE CONDUIT AND CONDUCTOR SCHEDULE. 2. SEE SHEET BT120-EPS104 FOR SITE LIGHTING CONDUIT AND CIRCUITING. 3. PROVIDE 5/8" X 10' COPPER GROUND ROD, #6 CU GND, AND EXOTHERMIC WELD TO ALL METAL BENCHES, BIKE RACKS, AND OTHER METAL OBJECTS LOCATED UNDER THE SCL POWER LINES. 4. THE ELECTRICAL CONDUIT INFRASTRUCTURE IS COMPRISED OF TWO DISTINCT AND PHYSICALLY SEPARATED SYSTEMS: ONE DESIGNATED FOR KING COUNTY METRO (KCM) AND THE OTHER FOR SOUND TRANSIT (ST). PROVIDE LABEL WITH THE RESPECTIVE OWNER'S IDENTIFICATION (KCM OR ST) IN ADDITION TO THE DISCIPLINE MARKER (ELECTRICAL) TO ALL JUNCTION BOX LIDS. N rec. no. 8702250475 REC NO. 9103110844 20' PUBLIC UTILITY EASEMENT BT120-HHLV-08 BT120-HHSC-09 BT120-HHLV-10 BT120-HHSC-11 101 101 101 101 129 129 1 BT120-EPP242 103 104 106106 105 106 105 1 BT120-EPP231 105 BT120-DBDC-111 BT120-DBSC-111 BT120-N2-106 BT120-N2-102 (1) 4"C BT120-DBDC-141 BT120-DBSC-131 BT120-DBDC-171 BT120-DBDC-161 BT120-DBSC-161 BT120-DBSC-151 J06 PV1 PV2 NEW TRANSFORMER VAULT PER PSE CUSTOMER DRAWING. 4"C, 2/0 SVC CABLE INSTALLED BY CONTRACTOR, CONNECTIONS BY PSE. 147 KEY NOTES: GENERAL NOTES: 1. SEE DWG BT120-ESP204, BT120-ESV201, AND BT120-EPD104 FOR DUCT BANK PLAN, PROFILE, AND TRENCH DETAIL. 2. SEE DWG BT120-EPS123 FOR BEB CHARGING YARD CONDUIT AND CONDUCTOR SCHEDULE. N P 1.B 1.C 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.E 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.151 BT120-ELP212 1 BT120-ELP213 1 BT120-ELP214 GENERAL NOTES: 1. LT FIXTURES TO BE ATTACHED TO COLUMNS ARE TO BE MOUNTED SO THAT THEIR LENSES ARE 9'-0" ABOVE THE GROUND BELOW. ALIGN AND COORDINATE WITH ARCHITECTURE FOR PENETRATION, CONDUIT FEED AND MOUNTING SCREWS. N P1.B 1.C 1.1 1.2 1.3 1.4 MA T C H L I N E : SE E D W G B T 1 2 0 -EL P 2 1 3 LF LF LF LF LF LF LF LF LG LF LF LF LF LF LF LF LF LF LF LF LF LT LG LF LF LF LF LT BT120-PB2-04: 4 305301 A BT120-EPD107 A BT120-EPE212 B BT120-EPE212 310 TYP GENERAL NOTES: 1. LT FIXTURES TO BE ATTACHED TO COLUMNS ARE TO BE MOUNTED SO THAT THEIR LENSES ARE 9'-0" ABOVE THE GROUND BELOW. ALIGN AND COORDINATE WITH ARCHITECTURE FOR PENETRATION, CONDUIT FEED AND MOUNTING SCREWS. KEY NOTES: N 1.B 1.C 1.5 1.6 1.7 1.E LF LF LF LF LG LF LF MA T C H L I N E : SE E D W G B T 1 2 0 -EL P 2 1 2 M A T C H L I N E : S E E D W G B T 1 2 0 - E L P 2 1 4 LF LF LF LF LG LF LF LT LF LF LF LF LT BT120-PB2-04: 2 A BT120-EPE213 B BT120-EPE213 310TYP GENERAL NOTES: 1. LT FIXTURES TO BE ATTACHED TO COLUMNS ARE TO BE MOUNTED SO THAT THEIR LENSES ARE 9'-0" ABOVE THE GROUND BELOW. ALIGN AND COORDINATE WITH ARCHITECTURE FOR PENETRATION, CONDUIT FEED AND MOUNTING SCREWS. KEY NOTES: N 1.E 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.15 LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF MATCH LINE: SEE DWG BT120-ELP213 LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LF LT LF LF LF LF LF LF LF LF LF LF LF LF LF LF LT BT120-PB2-04: 3 BT120-PB2-04: 1 A BT120-EPE214 B BT120-EPE214 310 TYP GENERAL NOTES: 1. LT FIXTURES TO BE ATTACHED TO COLUMNS ARE TO BE MOUNTED SO THAT THEIR LENSES ARE 9'-0" ABOVE THE GROUND BELOW. ALIGN AND COORDINATE WITH ARCHITECTURE FOR PENETRATION, CONDUIT FEED AND MOUNTING SCREWS. KEY NOTES: N REC NO 8502040500: 10' ELEC ESM TO PSE CENTERED ON BURIED UTILS SOMEWHERE WITHIN THE WEST 20' OF PARCEL AS CONSTRUCTED. UTIL LOCATIONS UNKNOWN. REC NO. 86030200379, OVERHEAD POWER ESMT TO SEATTLE CITY LIGHT AFN 3180315, OVERHEAD POWER ESMT TO SEATTLE CITY LIGHT, LESS THE EASTERLY PORTION THEREOF RELEASED BUT REPLACED BY REC NO. 86030200379. LIES N OF FORMER RR R/W AFN 3364759, 162.5' WIDE ELEC POWER TRANSMISSION ESM , LYING SOUTH OF 7TH St AND NORTH OF FORMER REC NO. 7408260266 10' WATERLINE EASEMENT REC NO. 8506060564 10' WATERLINE EASEMENT REC NO. 20110812001718 VARYING WIDTH SLOPE & UTILITY EASEMENT RGRG RG RG RG RG RG CG CG RG CG SFSFMRMR SF MR SF SF SF MR MR CS MP MPMP MP MP MP MPMPMP MPMP MP MP MP WRWRWRWRWRWRWR ND ND NDND ND ND NDND ND ND CG CG CG CGCG CG CG CG CG CGCGCGCGCGCG CGCG CG RG RG RG RG RG RGRG RGRG RG CS CS CSCSCSCS CS CSCS CS CS RGRG RGRG RG CGCG CG CGCG CGCG CS CS CS CS CGCG CGCG CG CGND NDNDND ND ND CG ND CGCG SFSFSF SFSFSFSFSFSF RG RG RGRG RG RGRGRG MRMRMRMRMRMRMRMRMR CS CS CS CS CS CSCS CS CGCGCGCG CGCGCGCG CGCGCG CG SFSF SFSFSFSF SF SF RG RG RGRG RGRG RG MRMR MRMR MRMRMR CS CSCS CS CS CS CS CG CGCGCG CG CG CGCG CGCGCG SFSFSFSFSFSFSFSFSFSFSFSF RGRGRGRG RGRGRG RG MRMRMR MRMRMR MRMRMRMR CS CS CS CS CS CS CGCG CG CGCG CGCG CGCG CG CG CG CG CG SFSFSFSF SFSFSF SFSF RG RGRGRG RG RG RG MRMR MRMRMR CSMRMR MRMR CS CSCS CSCS CGCG CGCGCG CG CG SFSFSF SFSFSF RG RG RG RG RG RGSF MRMRMR MRMRMR CS CS CS CS CS CS CS CGCGCG SFSFSFSFSFSFSF SFSFSFSF SFSFSF RG RG RG RGRG MRMRMRMR MRMR SF SF SF SFSF SFCSCSCSCSCSCSMRCG CGCG CG CG CG CG CG CG SF SF RG RGRGRGRGRGRGMRMRMRMR MRMRMRMR CS CS CS CSCSCS CG CGCG CG CG CG CGCG CG SFSF SF SF SFSF SF SF SF SF RGRG RGRGRGRGRGMRMRMR MRMRMRMR CS CS CSCS CSCS CG CGCG CG CGCG CG SFSF SF SF SFSF SF SF SF SF MRMR MR MRMR MR MR MRMR MRMRMRMRMRMR MR MRMRMR BUS BAY 7 BUS BAY 6 BUS BAY 5 BUS BAY 2 BUS BAY 8 BUS BAY 3 BUS BAY 4 BUS BAY 1 48 48 48 48 CB1 CB1 CB1L CB1L CB1 CB1 CB1 CB1 CB1 CB1 48 CB1L 48 48 CB1 48 1.B 1.C 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.E 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.15 1 BT120-EPP212 1 BT120-EPP213 1 BT120-EPP214 1 1 1 GENERAL NOTES: 1. BT120-2-0XX DENOTES THE ELECTRICAL CONDUIT CALLOUT. SEE SHEET BT120-EPS122 FOR CONDUIT AND CONDUCTOR SCHEDULE. 2. ALL SOUND TRANSIT PLATFORM CIRCUITS ARE FED FROM PANEL BT120-PB2-04. SEE PANEL SCHEDULE ON SHEET BT120-EPS116. 3. SEE GENERAL NOTES, LEGEND, AND ABBREVIATIONS ON SHEET BT120-EPN001. 4. SEE TELECOMM PLAN SHEETS BT120-JCP206 TO BT120-JCP209 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET 5. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE. 6. THE ELECTRICAL CONDUIT INFRASTRUCTURE IS COMPRISED OF TWO DISTINCT AND PHYSICALLY SEPARATED SYSTEMS: ONE DESIGNATED FOR KING COUNTY METRO (KCM) AND THE OTHER FOR SOUND TRANSIT (ST). PROVIDE LABEL WITH THE RESPECTIVE OWNER'S IDENTIFICATION (KCM OR ST) IN ADDITION TO THE DISCIPLINE MARKER (ELECTRICAL) TO ALL JUNCTION BOX LIDS. 7.SEE SHEET BT120-EPS121 FOR HANDHOLE SCHEDULE. 8.SEE SHEET BT120-EPS104 FOR SITE LIGHTING CONDUIT AND CIRCUITING. N 1.B 1.C 1.1 1.2 1.3 1.4 MATCH LINE: SEE DWG BT120-EPP213BT120-HH-SL-10 TVM 7 PYLON 5BT120-LCP-02 SYSTEM CABINET (SEE DETAIL 3 ON SHEET BT120-JCD208) BT120-PB2-04 BT120-HHLV-23 BT120-HHLV-16 A BT120-EGS101 BT120-2-001 BT120-2-002 BT120-2-003 BT120-2-004 BT120-2-005 BT120-2-010 BT120-2-009 BT120-2-006 BT120-2-007 BT120-2-008 BT120-2-011 BT120-2-012 BT120-2-013 (2)1" SPARE CONDUITS 133TYP A BT120-EPE212 B BT120-EPE212 BT120-2-018 BT120-2-019 BT120-2-020 1 GENERAL NOTES: 1. BT120-2-0XX DENOTES THE ELECTRICAL CONDUIT CALLOUT. SEE SHEET BT120-EPS122 FOR CONDUIT AND CONDUCTOR SCHEDULE. 2. ALL SOUND TRANSIT PLATFORM CIRCUITS ARE FED FROM PANEL BT120-PB2-04. SEE PANEL SCHEDULE ON SHEET BT120-EPS116. 3. SEE GENERAL NOTES, LEGEND, AND ABBREVIATIONS ON SHEET BT120-EPN001. 4. SEE TELECOMM PLAN SHEETS BT120-JCP206 TO BT120-JCP209 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET 5. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE. 6. THE ELECTRICAL CONDUIT INFRASTRUCTURE IS COMPRISED OF TWO DISTINCT AND PHYSICALLY SEPARATED SYSTEMS: ONE DESIGNATED FOR KING COUNTY METRO (KCM) AND THE OTHER FOR SOUND TRANSIT (ST). PROVIDE LABEL WITH THE RESPECTIVE OWNER'S IDENTIFICATION (KCM OR ST) IN ADDITION TO THE DISCIPLINE MARKER (ELECTRICAL) TO ALL JUNCTION BOX LIDS. 7.SEE SHEET BT120-EPS121 FOR HANDHOLE SCHEDULE. 8.SEE SHEET BT120-EPS104 FOR SITE LIGHTING CONDUIT AND CIRCUITING. KEY NOTES: N 1.B 1.C 1.5 1.6 1.7 1.E MATCH LINE: SEE DWG BT120-EPP212 M A T C H L I N E : S E E D W G B T 1 2 0 - E P P 2 1 4 BT120-HHLV-19 B BT120-EGS101 BT120-HHLV-20 BT120-2-012 BT120-2-013 (2)1" SPARE CONDUITS BT120-2-018 BT120-2-019 BT120-2-020 BT120-2-014 BT120-2-021 BT120-2-015 BT120-2-016 BT120-2-017 BT120-2-022 BT120-2-023 BT120-2-024 KCM-2-006 KCM-2-005133TYP A BT120-EPE213 B BT120-EPE213 1 GENERAL NOTES: 1. BT120-2-0XX DENOTES THE ELECTRICAL CONDUIT CALLOUT. SEE SHEET BT120-EPS122 FOR CONDUIT AND CONDUCTOR SCHEDULE. 2. ALL SOUND TRANSIT PLATFORM CIRCUITS ARE FED FROM PANEL BT120-PB2-04. SEE PANEL SCHEDULE ON SHEET BT120-EPS116. 3. SEE GENERAL NOTES, LEGEND, AND ABBREVIATIONS ON SHEET BT120-EPN001. 4. SEE TELECOMM PLAN SHEETS BT120-JCP206 TO BT120-JCP209 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET 5. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE. 6. THE ELECTRICAL CONDUIT INFRASTRUCTURE IS COMPRISED OF TWO DISTINCT AND PHYSICALLY SEPARATED SYSTEMS: ONE DESIGNATED FOR KING COUNTY METRO (KCM) AND THE OTHER FOR SOUND TRANSIT (ST). PROVIDE LABEL WITH THE RESPECTIVE OWNER'S IDENTIFICATION (KCM OR ST) IN ADDITION TO THE DISCIPLINE MARKER (ELECTRICAL) TO ALL JUNCTION BOX LIDS. 7.SEE SHEET BT120-EPS121 FOR HANDHOLE SCHEDULE. 8.SEE SHEET BT120-EPS104 FOR SITE LIGHTING CONDUIT AND CIRCUITING. KEY NOTES: N 1.E 1.8 1.9 1.10 1.11 1.12 1.13 1.14 1.15 MATCH LINE: SEE DWG BT120-EPP213 MATCH LINE: SE E D W G B T 1 2 0 -EP P 2 1 5 KCM-PB2-03 C BT120-EGS101 BT120-HHLV-17 BT120-HHLV-21 BT120-HHLV-22 BT120-HHLV-18 KCM-2-005 KCM-2-006 BT120-2-024 BT120-2-023 BT120-2-026 KCM-2-001 KCM-2-002 KCM-2-003 BT120-2-027 KCM-2-004 BT120-2-025 KCM-2-007 KCM-2-008 BT120-2-029 BT120-2-028 BT120-2-031 KCM-2-010 BT120-2-030 KCM-2-011 BT120-2-032 BT120-2-033 133 TYP A BT120-EPE214 B BT120-EPE214 BT120-N2-208 BT120-HHLV-31 BT120-HHLV-30 BT120-HHLV-32 KCM-2-009 GENERAL NOTES: 1. BT120-2-0XX DENOTES THE ELECTRICAL CONDUIT CALLOUT. SEE SHEET BT120-EPS122 FOR CONDUIT AND CONDUCTOR SCHEDULE. 2. ALL SOUND TRANSIT PLATFORM CIRCUITS ARE FED FROM PANEL BT120-PB2-04. SEE PANEL SCHEDULE ON SHEET BT120-EPS116. 3. SEE GENERAL NOTES, LEGEND, AND ABBREVIATIONS ON SHEET BT120-EPN001. 4. SEE TELECOMM PLAN SHEETS BT120-JCP206 TO BT120-JCP209 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET 5. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE. 6. THE ELECTRICAL CONDUIT INFRASTRUCTURE IS COMPRISED OF TWO DISTINCT AND PHYSICALLY SEPARATED SYSTEMS: ONE DESIGNATED FOR KING COUNTY METRO (KCM) AND THE OTHER FOR SOUND TRANSIT (ST). PROVIDE LABEL WITH THE RESPECTIVE OWNER'S IDENTIFICATION (KCM OR ST) IN ADDITION TO THE DISCIPLINE MARKER (ELECTRICAL) TO ALL JUNCTION BOX LIDS. 7.SEE SHEET BT120-EPS121 FOR HANDHOLE SCHEDULE. 8.SEE SHEET BT120-EPS104 FOR SITE LIGHTING CONDUIT AND CIRCUITING. KEY NOTES: N 1.E MATCH LINE: SEE DWG BT120-EPP214 BT120-HH-SL-24 BT120-HH-SL-25 C BT120-EGS101 KCM-2-009 BT120-2-033 SEE SYSTEM CABINET SHEETS BT120-JCP206, BT120-JCP207,BT120- JCP208 AND BT120-JCP209 FOR COMMUNICATIONS SITE PLANS 1 GENERAL NOTES: 1. BT120-2-0XX DENOTES THE ELECTRICAL CONDUIT CALLOUT. SEE SHEET BT120-EPS122 FOR CONDUIT AND CONDUCTOR SCHEDULE. 2. ALL SOUND TRANSIT PLATFORM CIRCUITS ARE FED FROM PANEL BT120-PB2-04. SEE PANEL SCHEDULE ON SHEET BT120-EPS116. 3. SEE GENERAL NOTES, LEGEND, AND ABBREVIATIONS ON SHEET BT120-EPN001. 4. SEE TELECOMM PLAN SHEETS BT120-JCP206 TO BT120-JCP209 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET 5. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE. 6. THE ELECTRICAL CONDUIT INFRASTRUCTURE IS COMPRISED OF TWO DISTINCT AND PHYSICALLY SEPARATED SYSTEMS: ONE DESIGNATED FOR KING COUNTY METRO (KCM) AND THE OTHER FOR SOUND TRANSIT (ST). PROVIDE LABEL WITH THE RESPECTIVE OWNER'S IDENTIFICATION (KCM OR ST) IN ADDITION TO THE DISCIPLINE MARKER (ELECTRICAL) TO ALL JUNCTION BOX LIDS. 7.SEE SHEET BT120-EPS121 FOR HANDHOLE SCHEDULE. 8.SEE SHEET BT120-EPS104 FOR SITE LIGHTING CONDUIT AND CIRCUITING. N GENERAL NOTES: 1. BT120-2-0XX DENOTES THE ELECTRICAL CONDUIT CALLOUT. SEE SHEET BT120-EPS122 FOR CONDUIT AND CONDUCTOR SCHEDULE. 2. ALL SOUND TRANSIT PLATFORM CIRCUITS ARE FED FROM PANEL BT120-PB2-04. SEE PANEL SCHEDULE ON SHEET BT120-EPS116. 3. SEE GENERAL NOTES, LEGEND, AND ABBREVIATIONS ON SHEET BT120-EPN001. 4. SEE TELECOMM PLAN SHEETS BT120-JCP206 TO BT120-JCP209 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET 5. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE. 6. THE ELECTRICAL CONDUIT INFRASTRUCTURE IS COMPRISED OF TWO DISTINCT AND PHYSICALLY SEPARATED SYSTEMS: ONE DESIGNATED FOR KING COUNTY METRO (KCM) AND THE OTHER FOR SOUND TRANSIT (ST). PROVIDE LABEL WITH THE RESPECTIVE OWNER'S IDENTIFICATION (KCM OR ST) IN ADDITION TO THE DISCIPLINE MARKER (ELECTRICAL) TO ALL JUNCTION BOX LIDS. 7.SEE SHEET BT120-EPS121 FOR HANDHOLE SCHEDULE. 8.SEE SHEET BT120-EPS104 FOR SITE LIGHTING CONDUIT AND CIRCUITING. BT120-LCP-02 BT120-HH-SL-10 BT120-HHLV-16 LIGHT (TYP) BT120-VMS-02 (NIC) BT120-VMS-01 (NIC) BT120-2-010 BT120-2-009 BT120-2-018 BT120-2-019 BT120-2-020 BT120-PB2-04 SYSTEMS CABINET STUB UP CONDUITS WHERE NEEDED 1 BT120-LCP-02 LIGHT (TYP) BT120-HHLV-23 BT120-PB2-04 SYSTEMS CABINET BT120-2-004 BT120-2-005 BT120-2-012 BT120-2-013 1 N GENERAL NOTES: 1. BT120-2-0XX DENOTES THE ELECTRICAL CONDUIT CALLOUT. SEE SHEET BT120-EPS122 FOR CONDUIT AND CONDUCTOR SCHEDULE. 2. ALL SOUND TRANSIT PLATFORM CIRCUITS ARE FED FROM PANEL BT120-PB2-04. SEE PANEL SCHEDULE ON SHEET BT120-EPS116. 3. SEE GENERAL NOTES, LEGEND, AND ABBREVIATIONS ON SHEET BT120-EPN001. 4. SEE TELECOMM PLAN SHEETS BT120-JCP206 TO BT120-JCP209 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET 5. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE. 6. THE ELECTRICAL CONDUIT INFRASTRUCTURE IS COMPRISED OF TWO DISTINCT AND PHYSICALLY SEPARATED SYSTEMS: ONE DESIGNATED FOR KING COUNTY METRO (KCM) AND THE OTHER FOR SOUND TRANSIT (ST). PROVIDE LABEL WITH THE RESPECTIVE OWNER'S IDENTIFICATION (KCM OR ST) IN ADDITION TO THE DISCIPLINE MARKER (ELECTRICAL) TO ALL JUNCTION BOX LIDS. 7.SEE SHEET BT120-EPS121 FOR HANDHOLE SCHEDULE. 8.SEE SHEET BT120-EPS104 FOR SITE LIGHTING CONDUIT AND CIRCUITING. BT120-HHLV-20 LIGHTS (TYP) SYSTEMS CABINET KCM-2-005 BT120-2-021 BT120-2-023 BT120-2-024 KCM-2-006 KCM-2-006 BT120-2-022 BT120-2-018 BT120-2-019 BT120-2-020 BT120-VMS-05 (NIC) BT120-VMS-06 (NIC) 1 BT120-HHLV-19 LIGHTS (TYP) BT120-VMS-07 (NIC) BT120-VMS-08 (NIC) NETWORK CABINET BT120-2-014 BT120-2-012 BT120-2-013 BT120-2-015 BT120-2-017 BT120-2-022 1 BT120-2-016 1 1 N GENERAL NOTES: 1. BT120-2-0XX DENOTES THE ELECTRICAL CONDUIT CALLOUT. SEE SHEET BT120-EPS122 FOR CONDUIT AND CONDUCTOR SCHEDULE. 2. ALL SOUND TRANSIT PLATFORM CIRCUITS ARE FED FROM PANEL BT120-PB2-04. SEE PANEL SCHEDULE ON SHEET BT120-EPS116. 3. SEE GENERAL NOTES, LEGEND, AND ABBREVIATIONS ON SHEET BT120-EPN001. 4. SEE TELECOMM PLAN SHEETS BT120-JCP206 TO BT120-JCP209 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET 5. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE. 6. THE ELECTRICAL CONDUIT INFRASTRUCTURE IS COMPRISED OF TWO DISTINCT AND PHYSICALLY SEPARATED SYSTEMS: ONE DESIGNATED FOR KING COUNTY METRO (KCM) AND THE OTHER FOR SOUND TRANSIT (ST). PROVIDE LABEL WITH THE RESPECTIVE OWNER'S IDENTIFICATION (KCM OR ST) IN ADDITION TO THE DISCIPLINE MARKER (ELECTRICAL) TO ALL JUNCTION BOX LIDS. 7.SEE SHEET BT120-EPS121 FOR HANDHOLE SCHEDULE. 8.SEE SHEET BT120-EPS104 FOR SITE LIGHTING CONDUIT AND CIRCUITING. BT120-HHLV-22 LIGHT (TYP) BT120-VMS-15 (NIC) BT120-VMS-16 (NIC) BT120-VMS-11 (NIC) BT120-VMS-12 (NIC) BT120-2-033 BT120-2-030 BT120-2-028 BT120-2-029 BT120-2-025 KCM-2-007 KCM-PB2-03 BT120-HHLV-21 BT120-HHLV-31 KCM-2-010 BT120-2-031 KCM-2-009 BT120-2-033 NETWORK CABINET KCM-2-001 KCM-2-002 1 BT120-HHLV-18 LIGHT (TYP) BT120-VMS-13 (NIC) BT120-VMS-14 (NIC) BT120-VMS-09 (NIC) BT120-VMS-10 (NIC) KCM-PB2-03 BT120-HHLV-17 KCM-2-003 KCM-2-004 BT120-2-027 BT120-2-032 KCM-2-011 BT120-HHLV-30 BT120-HHLV-32 KCM-2-008 BT120-2-031 BT120-2-026 BT120-N2-208 KCM-2-003 1 1 N OD D O ODODODOD OO O O D O P JANITOR BT120L1203 OPERATOR RESTROOM BT120L1204 OPERATOR RESTROOM BT120L1205 OPERATOR RESTROOM BT120L1206 OPERATOR RESTROOM BT120L1207 TELECOM BT120L1208 ELECTRICAL BT120L1209 STORAGE 1 BT120L1210 2.F 2.A 2.112.102.9 2.G 2.D 2.J LM-1 LM-1E LB LT LT LTLBLD-ELD-E LT LD-ELD-E LB-E LT LB-E LBLB LB LB-E LT LB LACTATION ROOM BT120L1202 2.8 2.72.62.5 2.42.32.22.1 2.C SEC STORAGE BT120L1201 SECURITY BLDG BT120L1200 LB-E LB LB LB LB LM-1 LM-1E LM-1 303 304 KCM-PB2-04: 11 BT120-PB2-03: 2 BT120-PB2-01: 11 BT120-PB2-03: 4 BT120-PB2-03: 4 BT120-PB2-03: 4 BT120-PB2-03: 4 BT120-PB2-03: 4 BT120-PB2-03: 4 BT120-PB2-03: 1BT120-PB2-03: 1 307 307 307 308 309 B BT120-EPD107 LT BT120-PB2-03: 4 311 312 311 311 311 311 311 LT BT120-PB2-03: 4 311 KEY NOTES: N SECURITY BLDG BT120L1200 LACTATION ROOM BT120L1202 JANITOR BT120L1203 OPERATOR RESTROOM BT120L1204 OPERATOR RESTROOM BT120L1205 OPERATOR RESTROOM BT120L1206 OPERATOR RESTROOM BT120L1207TELECOM BT120L1208 ELECTRICAL BT120L1209 STORAGE 1 BT120L1210 1 BT120-EPP223 2.F 2.A 2.112.102.9 2.G 2.D 2.J SEC STORAGE BT120L1201 2.82.72.62.52.42.32.22.1 2.C WP WP BT120-PB2-01 120 119119 BT120-PB2-01: 10,12 BT120-EWH-04 BT120-PB2-01: 9 BT120-PB2-01: 8 BT120-PB2-01: 7 BT120-PB2-01: 6 BT120-PB2-01: 5 BT120-PB2-01: 4 BT120-PB2-01: 2 BT120-ACU-01 BT120-PB2-01: 1,3 BT120-ACU-07 1 BT120-EPP222 123 A BT120-EGS102 BT120-PB2-03: 20 BT120-PB2-03: 17,19 BT120-RD-01 +42" +42" +42" +42" BT120-DISC-09 BT120-DISC-10 1 KEY NOTES: N 2.A 2.G 2.D 2.82.72.62.5 OPERATOR RESTROOM BT120L1207 OPERATOR RESTROOM BT120L1206 OPERATOR RESTROOM BT120L1205 OPERATOR RESTROOM BT120L1204 JANITOR BT120L1203 LACTATION ROOM BT120L1202 SEC STORAGE BT120L1201 BT120-ACU-26 BT120-HPMP-02 BT120-HPMP-01 BT120-ACU-16 BT120-ACU-36 BT120-HPMP-03 BT120-HPMP-04 BT120-ACU-46 BT120-HPMP-06 BT120-HPMP-07 BT120-PB2-03: 5 BT120-HTR-02 BT120-PB2-03: 6 BT120-EWH-03 BT120-ACU-56 BT120-PB2-03: 15 BT120-EWH-06 BT120-PB2-03: 11,13 BT120-HPMP-06 BT120-PB2-03: 10,12 BT120-HPMP-06 BT120-PB2-03: 7 BT120-ERU-01 BT120-PB2-03: 6 BT120-PB2-03: 8 BT120-HTR-01 BT120-PB2-03: 6BT120-PB2-03: 6BT120-PB2-03: 6 BT120-PB2-03: 6 BT120-PB2-03: 6 BT120-EWH-05 120 BT120-PB2-03: 9 BT120-PB2-03: 9 124 124124124 124 A BT120-EGS102 BRANCH UNIT BRANCH UNIT W PNEMA 3R NEMA 3R NEMA 3RNEMA 3R NEMA 3RNEMA 3R WP NEMA 3R BT120-HPMP-05 BT120-SWBD-02: 13,15 BT120-SWBD-02: 17,19 KCM-PB2-04:12,14 BT120-SWBD-02: 21,23 BT120-PB2-05:12, 14 BT120-SWBD-02: 33,35 BT120-SWBD-02: 37,39 BT120-SWBD-02: 26, 28, 30 BT120-SWBD-02: 22, 24 BT120-EWH-01 BT120-SWBD-02:14, 16 BT120-EWH-02 BT120-SWBD-02:18, 20 BT120-PB2-03: 25 144 BT120-DISC-01 BT120-DISC-02BT120-DISC-03 BT120-DISC-04 BT120-DISC-05 BT120-DISC-06 BT120-DISC-07 BT120-DISC-08 KEY NOTES: N FI X FI X FIX CRCRCR FIXFIX ELECTRICAL BT120L1209 2.A 2.G 2.D BT120-ATS-01 BT120-SWGR-01 BT120-PB2-06 BT120-PB2-03 2.52.42.32.22.1 BT120-SWBD-02 BT120-T-01 BT120-T-02 45KVA XMFR 150KVA XMFR KCM-PB2-02 BT120-PB4-01 BT120-SWBD-01 BT120-UPS-01 20KW UPS BT120-LCP-01 CTL BT120-PB2-02 KCM-MBP-01 KCM-UPS-1 75KVA XMFR KCM-T-02 8KW UPS TELECOM BT120L1208 BT120-ACU-05 BT120-PB2-05: 4 BT120-PB2-05: 2KCM-PB2-04: 10 KCM-PB2-04: 1 BT120-PB2-03: 18 TELECOM BT120L1208 BT120-PB2-03: 20 BT120-ACU-02 121 (TYPICAL FOR TELECOM ROOM) KCM-PB2-04 BT120-PB2-05 BT120-ACU-03 123 123 BT120-ACU-04 A BT120-EGS102 BT120-PB2-05: 1 BT120-ACP-01 +48"BT120-PB2-05: 15 BT120-BMS-01 C BT120-EPE221 D BT120-EPE221 A BT120-EPE221 B BT120-EPE221 BT120-PB2-03:16 137 138 139 L5-30R BT120-PB2-05: 7 L5-30R BT120-PB2-05: 9 L5-30R BT120-PB2-05: 6 L5-30R BT120-PB2-05: 8 L5-30R BT120-PB2-05: 3 L5-30R BT120-PB2-05: 5 L5-30R KCM-PB2-04: 7 L5-30R KCM-PB2-04: 9 L5-30R KCM-PB2-04: 4 L5-30R KCM-PB2-04: 5 L5-30R KCM-PB2-04: 8 L5-30R KCM-PB2-04: 2 L5-30R KCM-PB2-04: 3 L5-30R KCM-PB2-04: 6 BT120-PB2-05: 22 BT120-PB2-05: 20 +54" +54" +54" BT120-CR-01A BT120-CR-02A BT120-CR-03A BT120-CR-01B BT120-CR-02B BT120-CR-03B BT120-CR-04A BT120-CR-04B L5-30R BT120-PB2-05: 11 L5-30R BT120-PB2-05: 13 1 KEY NOTES: N KEY NOTES: 2.A 2.G2.D KCM-T-02 KCM-PB2-02 KCM-MBP-01 KCM-UPS-1 2.4 2.3 2.2 2.1 BT120-PB2-02 BT120-UPS-01 BT120-PB2-03 BT120-T-01 BT120-SWBD-02 BT120-LCP-01 2.A2.G 2.D BT120-T-01 BT120-PB4-01 BT120-SWBD-01 BT120-ATS-01 BT120-SWGR-01 137 2.42.32.22.1 BT120-SWGR-01 BT120-PB2-06 BT120-T-02 KCM-T-02 1 3.2 3.3 3.4 LU LU LU LU LU LU LU LU 3.A 3.B KCM-PB2-01: 3 3.1 GENERAL NOTES: 1. REFERENCE PANTOGRAPH INSTALLATION MANUAL FOR CABINET INSTALLATION AND TERMINATION OF WIRING. N 3.2 3.3 3.4 BT120-BEB01PC-01 BT120-BEB01PC-01A BT120-BEB01PC-02A BT120-BEB01PC-02 BT120-BEB01PC-03A BT120-BEB01PC-03 BT120-BEB01PC-04 BT120-BEB01PC-04A BT120-BEB01PC-05A BT120-BEB01PC-05 BT120-BEB01PC-06A BT120-BEB01PC-06 BT120-BEB01PC-07A BT120-BEB01PC-07 BT120-BEB01PC-08A BT120-BEB01PC-08 BT120-BEB01PC-09A BT120-BEB01PC-09 BT120-BEB01PC-10A BT120-BEB01PC-10 BT120-BEB01PC-11A BT120-BEB01PC-11 BT120-BEB01PC-12A BT120-BEB01PC-12 3.1 A BT120-EPD102 BT120-DBDC-111 BT120-DBSC-111 3.2 3.3 3.4 A - PANTOGRAPH KIT (PROPOSED) FUTURE PANTOGRAPH KIT FUTURE PANTOGRAPH KIT 3.A 3.B 105 3.1 116 TYP TYP A BT120-EPD102 134 TYP (TYP) 2' - 2" FUTURE PANTOGRAPH KIT 10' - 5 3/8" 25' - 2 5/8" 40' - 0" 12' - 9 3/4" 27' - 6 3/4" 42' - 2 3/4" 10' - 10 3/8" 25' - 7 5/8" 40' - 4 5/8" 12' - 4 3/8" 27' - 2 3/8" 41' - 9 3/8" 135 136 TYP TYP BT120-DBDC-111 BT120-DBSC-111 E-STOP 145 KEY NOTES: GENERAL NOTES: 1. ALL PANTOGRAPH DIMENSIONS TO CENTER MOUNTING HOLE. SEE DETAIL ON SHEET BT120-EPD108. 2. SEE DWG BT120-EPD109 FOR ACM CONTROL BOX PENETRATION DETAILS. N P WP , OR 4.B 4.A 4.1 4.2 4.3 4.4 4.5 302 LF LF LFLFLFLFLFLFLF LFLFLFLFLFLF LF 306 KCM-PB2-01: 1 C BT120-EPD107 KEY NOTES: N (FUTURE) NEMA 3R SWGR FOR 2ND CHARGING SERVICE FRONT 4FT FRONT WORKING CLEARANCE CORE FACILITY S XFMR 2MVA TRANSFORMER FUTURE 2MVA TRANSFORMER FR O N T FR O N T FR O N T FR O N T SYSTEM CABINET (SEE DETAIL 3 ON SHEET BT120-JCD208) (FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE) (FUTURE)(FUTURE)(FUTURE)(FUTURE) (FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE) 300kW CHARGER CABINETS (TYP) 4.B 4.A 4.1 4.2 4.3 4.4 4.5 BT120-HHSC-04 BT120-HHLV-05 BT120-HHLV-07 BT120-HHSC-06BT120-HHLV-01 BT120-HHLV-02 KCM-SWBD-01 KCM-PB2-01 KCM-T-1 BT120-BEB-01A BT120-BEB-01B BT120-BEB-02A BT120-BEB-02B BT120-BEB-03A BT120-BEB-03B BT120-BEB-04A BT120-BEB-04B BT120-BEB-05A BT120-BEB-05B BT120-BEB-06A BT120-BEB-06B BT120-BEB-12B BT120-BEB-12A BT120-BEB-11B BT120-BEB-11A BT120-BEB-10B BT120-BEB-10A BT120-BEB-09B BT120-BEB-09A BT120-BEB-08B BT120-BEB-08A BT120-BEB-07B BT120-BEB-07A BT120-T-100 BT120-T-101 BT120-T-102 BT120-LCP-03 TELECOM HH KCM-PB2-01: 2 WP GFCI NEMA 3R BT120-HHSC-03 N WP , OR 4.B 4.A 4.1 4.2 4.3 4.4 4.5FUTURE 300kW CHARGER CABINETS (TYP) (FUTURE) NEMA 3R SWGR FOR 2ND CHARGING SERVICE FRONT CORE FACILITY S XFMR 2MVA TRANSFORMER FUTURE 2MVA TRANSFORMER FR O N T FR O N T FR O N T FR O N T 300kW CHARGER CABINETS (TYPICAL) SYSTEM CABINET (SEE DETAIL 3 ON DWG BT120-JCD201) KCM-PB2-01: 6 (FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE) (FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE)(FUTURE) BT120-DB4-111& (6)3"C SPARES BT120-HHSC-04 BT120-HHLV-05 BT120-HHLV-07 BT120-HHSC-06 BT120-HHLV-01 BT120-HHLV-02 KCM-SWBD-01 KCM-PB2-01 KCM-T-1 BT120-LCP-03 (TYP) 111 LIGHTING CONTROL PANEL (8)4"C FOR PSE SECONDARY CONDUCTORS. STUB UP WITH CAP AT FUTURE SWITCHBOARD LOCATION (8)4"C FOR PSE SECONDARY CONDUCTORS (12)3"C SPARE CONDUITS 126 126 127 127 128 128 BT120-SC-177 (8)4"C BETWEEN PSE VAULTS FOR FUTURE SECONDARY CONDUCTORS BT120-N4-123 BT120-N4-124 BT120-N4-125 BT120-N4-126 BT120-DBDC-121 BT120-DBDC-101 BT120-DBSC-121 BT120-DBDC-151 BT120-DBSC-141 WP, GFCI KCM-PB2-01: 1 BT120-N4-105 BT120-N4-117 BT120-N2-101 BT120-N2-104 BT120-N2-103 BT120-N4-121 BT120-N4-122 111 BT120-DB4-131 BT120-DB4-171 BT120-SC-176 BT120-SC-175 BT120-SC-174 146 BT120-SC-184 BT120-SC-185 BT120-SC-186 KEY NOTES: GENERAL NOTES: 1. REFERENCE PANTOGRAPH INSTALLATION MANUAL FOR CABINET INSTALLATION AND TERMINATION OF WIRING. N G GGGGG G GGGGGGGGGGGGGGGGGGGGGG G GGGGG G GGGG G GGGGGGGGGGGGGGGGGG G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G GGGGGG 1.11.21.31.4 #4 GND TO BUS BAY 2 #6 BOND TO GROUND ROD 5/8" X 10' GROUND ROD IN HANDHOLE BT120-HHLV-16 FOUNDATION METAL REINFORCEMENT, TYP. #4 GND #4 BOND TO STRUCTURAL STEEL #4 BOND TO STRUCTURAL STEEL BT120-PB2-04 PANEL INSIDE CABINET. GND BAR IN PANEL #4 1.51.61.7 #4 BOND TO STRUCTURAL STEEL #4 GND TO BUS BAY 3 FOUNDATION METAL REINFORCEMENT, TYP. #4 GND #6 BOND TO GROUND ROD 5/8" X 10' GROUND ROD IN HANDHOLE BT120-HHLV-20 #4 BOND TO STRUCTURAL STEEL #4 GND TO BUS BAY 1 1.81.91.101.111.121.131.141.15 #4 GND TO BUS BAY 2#6 BOND TO GROUND ROD 5/8" X 10' GROUND ROD IN HANDHOLE BT120-HHLV-17 KCM-3 PANEL INSIDE CABINET GND BAR IN PANEL #4 #4 BOND TO STRUCTURAL STEEL #4 BOND TO STRUCTURAL STEEL #6 BOND TO GROUND ROD 5/8" X 10' GROUND ROD IN HANDHOLE BT120-HHLV-18 FOUNDATION METAL REINFORCEMENT, TYP. #4 GND #4 GND GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGG G G G G G G G G G 2.112.102.92.82.72.62.52.42.32.22.1 #3/0 BOND TO STRUCTURAL STEEL #3/0 BOND TO STRUCTURAL STEEL 125 125 FOUNDATION METAL REINFORCEMENT, TYP. #3/0 GND #6 #2 TGB #3/0 BT120-SWGR-01 BT120-T-01 #6 #4 ELECTRICAL BT120L1209 TELECOM BT120L1208 TELECOM BT120L1208 OPERATOR RESTROOM BT120L1206 OPERATOR RESTROOM BT120L1205 OPERATOR RESTROOM BT120L1204 JANITOR BT120L1203 LACTATION ROOM BT120L1202 SEC STORAGE BT120L1201 SECURITY BLDG BT120L1200 BT120-T-02 TKCM-2 KCM TELECOM TGB ST TELECOM TGB #3/0 #3/0 WATER SERVICE #3/0 #8 PANEL BT120-PB2-01 #3/0 CHAINLINK FENCE BURNDY FFGC OR EQUAL KEY NOTES: GG G G G G GG GG G G G G GG GG G G G G GG 3.2 3.3 3.4 3.A 3.B 3.1GG GGG #1/0 CU BARE COPPER GROUND LOOP BURIED MINIMUM 30" BELOW FINISHED GRADE. REBAR (TYP) G G G GG G G GG #1/0 CU BARE COPPER GROUND LOOP BURIED MINIMUM 30" BELOW FINISHED GRADE. REBAR (TYP) G #1/0 CU BARE COPPER GROUND LOOP BURIED MINIMUM 30" BELOW FINISHED GRADE. REBAR (TYP) G G G G G 2 BT120-EPD111 (TYP) 4 BT120-EPD111 (TYP) 6 BT120-EPD111 (TYP) 3 BT120-EPD112 (TYP)125 KEY NOTES: N G GGGGGGGGGGG G G G G G G GGGGGGGGGGGGGGGGGG G G G 4.B 4.A 4.1 4.2 4.3 4.4 4.5 G G G G G GG GG GGGG GGGGGG G G REBAR (TYP)#4/0 CU BARE COPPER GROUND LOOP BURIED MINIMUM 30" BELOW FINISHED GRADE. 6 BT120-EPD111 (TYP) 2 BT120-EPD111 (TYP) 3 BT120-EPD112 (TYP) 3 BT120-EPD111 (TYP)4 BT120-EPD111 (TYP) 1 BT120-EPD111(TYP) N 8" DIA. SUMP GALVANIZED PULL/LIFT IRON (1 EACH CORNER) 2'-0" LONG GALVANIZED "C" CHANNEL (1 EACH WALL) FOR CABLE RACKS 3 ' - 6 " 3 ' - 0 " 6 " 2 ' - 8 " 4 " 1'-6" LONG GALVANIZED "C" CHANNEL (1 EACH WALL) FOR CABLE RACKS 1 ' - 4 " 1 ' - 0 " 8 " 1 ' - 2 " SECTION AA END VIEW 1' - 6" 1' - 4" 1' - 4" 1 ' - 0 " 1 ' - 6 " 6 " 1 1 " 18" X 18" KNOCKOUT (1 EACH END) 12" X 12" KNOCKOUT (2 EACH END) BT120-HHLV-12, BT120-HHLV-13, BT120-HHSC-25, BT120-HHLV-26, BT120-HHLV-271 3.A 3.B 10"Wx10Dx24"H LOW VOLTAGE PULLBOX 24"Wx18Dx24"H DC PULLBOX (9) 3" DC CONDUITS(3) 3" NETWORK CONDUITS NOTE: PROVIDE LOW VOLTAGE AND DC PULLBOXES FOR ALL CONDUIT RISER LOCATIONS IN GANTRY. BT120-DBDC-111 BT120-DBSC-111 3' - 0" E-STOP BT120-SC-181 BT120-SC-182 BT120-SC-183 GROUT TO FULL WALL THICKNESS AROUND CONDUITS AT KNOCKOUTS, TYP GALVANIZED "C" CHANNEL INSERTS, 3'-0" LONG 4 PULLING IRONS, 1 EACH CORNER 2 1/2" DIA. GROUND ROD KNOCKOUT 2 PLACES IN FLOOR INCOMING CONDUITS FROM CHARGING YARD #4/0G COMPACTED GRAVEL, 12" DEEP MIN, 3/4" MINUS STANCHION FOR MOUINTING CABLE RACKS 10 CF 1" TO 1-1/2" GRAVEL, ALL AROUND DRAIN CABLE RACK, 3 EA STANCHION OUTGOING CONDUITS TO GANTRY GROUND ROD SST CLAMP, TYP HUB NUMBER OF CONDUITS AS REQUIRED ADAPTER REQUIRED FOR PVC CONDUITS CONDUIT, SIZE PER PLANS PROVIDE CONTINUOUS GROUND PATH PER NEC REQUIREMENTS CLOSED CELL NEOPRENE RGS CONDUIT, 6" MIN NOTES: RGS CONDUIT 3/4" PREMOLDED JOINT FILLER MIN 3/4"x5"x FULL WIDTH OF ENCASEMENT NEOPRENE BRG PAD EXPANSION/DEFLECTIONCOUPLING BUILDING FOUNDATION AND CORBEL #4 DOWELS @ 1' -6" ADHESIVE DOWELS W/ 6" MIN EMBEDMENT. MIN 2 TOP AND BOTTOM. (4 TOTAL)CORBEL, SEE STRUCTURAL DRAWINGS ELEVATION DETAIL APPLIES TO CONDUIT AT BUILDING INTERFACES.1. 2-#5 HOOPS, 2" CLEAR 3/ 4 " THE ENDS OF ALL CONDUITS REQUIRED TO BE GROUNDED BY THE SPECIFICATIONS SHALL BE GROUNDED IN ACCORDANCE WITH THIS DETAIL. GROUND WIRE EQUIPMENT ENCLOSURE METAL CONDUIT GROUNDING BUSHING NOTES: 1. LOCK NUT 1 DOUBLE RACK FRAMING CHANNEL CONDUIT SIZE AS REQUIRED 1.5 MIN BOTTOM OF STEEL OR CONCRETE STRUCTURE NOTES: LENGTH VARIES WITH NUMBER OF CONDUITS TO BE SUPPORTED AND SPACING BETWEEN CONDUITS. SUBMIT FINAL DESIGN AND CALCULATIONS FOR SUPPORT AND ANCHORAGE AS SPECIFIED. USE STAINLESS STEEL HARDWARE IN WET AND/OR CORROSIVE AREAS. SPACE CONDUIT SUFFICIENTLY TO ALLOW REMOVAL OF ONE CONDUIT WITHOUT DISTURBING ADJACENT CONDUITS. 1. 2. 3. 4. SEISMIC BRACE TO ROOF OR TOP OF FLOOR BEAM ABOVE UNLESS BRACED TO WALL. 5" MIN 5" M IN AS REQUIRED, NOTE 1 "T" CONDULET FLOOR 1. 2. 3. LE N G T H S H A L L N O T E X C E E D M A X I M U M VA L U E A L L O W E D B Y N E C O R 10 ' -0" M A X I M U M FLEX CONDUIT TO MOTOR OR OTHER DEVICE RIGID METAL CONDUIT (1" MIN SIZE) FLOOR FLANGE AND A MINIMUM OF 4 CONCRETE ANCHORS SUPPORT, NOTE 3 NOTES: INSTALLATION OF CONDUIT TO A MOTOR OR OTHER DEVICE WHERE A FLEXIBLE CONNECTION IS REQUIRED AND NO JUNCTION BOXES OR CONTROL DEVICES ARE REQUIRED SHALL BE MADE IN ACCORDANCE WITH THIS DETAIL. ALL HARDWARE SHALL BE STAINLESS STEEL. SUBMIT FINAL DESIGN AND CALCULATIONS FOR SUPPORT AND ANCHORAGE AS SPECIFIED. 1' - 0" MIN UNS UPPORT ED SINGLE DEVICE BOX WITH PLASTER RING GROUT FILL CELL CONTAINING BOX, DO NOT LOCATE IN A REINFORCED CELL SINGLE DEVICE BOX WITH PLASTER RING PLAN SECTIONNOTES: ALL WIRING DEVICE BOXES MOUNTED IN CONCRETE BLOCK WALLS SHALL BE INSTALLED IN ACCORDANCE WITH THIS DETAIL. PARALLEL CONDUIT NOT PERMITTED IN CELLS WITH VERTICAL REINFORCING. DO NOT CUT OR DISPLACE VERTICAL REINFORCING OR DOWELS. 1. 2. PER SPECIFICATIONS AS REQUIRED D = 3" FOR 2" AND LARGER CONDUITS UNLESS OTHERWISE NOTED D = 2" FOR 1 1/2" AND SMALLER CONDUITS UNLESS OTHERWISE NOTED COPPER GROUND CONDUCTOR, TYP NOTES: PROVIDE 6" MINIMUM COMPACTED GRAVEL, 3/4" MINUS, UNDER ALL CONCRETE ENCASED DUCT RUNS. 1. 3" CLR, (TYP BOT) 2" CLR, (TYP TOP AND SIDES) #4 STIRRUPS @18" MAX, TYP #4 LONGITUDINAL BARS @18" OC MAX, LAP BOTTOM BARS 1'-6" AND LAP OTHER BARS 1'-11" MIN, TYP #4@18", TYP #4@18" TOP AND BOTTOM WITH 2'-0" LAP, TYP 4" M I N 5" M IN 4" MIN 4" MIN 4" MIN 5" MIN 4" MIN D 4" MIN 4" MIN D4" MIN 5" MIN D 4 " MIN FOR LARGER DUCT BANKS, CONTINUE PATTERN OF REBAR, CONDUIT SEPARATION AND CONCRETE COVER. COPPER GROUND CONDUCTOR, TYP @ 18" VERT LEGS 1'-0" MIN #4 @ 18" VERT LEGS 1'-6" MIN #4 4" M I N D 5 " MIN 4" MIN D D 4" MIN 4" MIN D 4" MIN D D HUB NOTE 3 1. 2. 3. ADAPTER REQUIRED FOR PVC CONDUITS CONDUIT, SIZE PER PLANS CLOSED CELL NEOPRENE STAINLESS STEEL CLAMP, TYP PROVIDE CONTINUOUS GROUND PATH PER NEC REQUIREMENTS FLEXIBLE NEOPRENE SLEEVE RGS CONDUIT, TYP NOTES: DETAIL APPLIES TO CONDUIT EMBEDDED IN STRUCTURAL CONCRETE AT BUILDING INTERFACES AND AT STRUCTURAL EXPANSION JOINTS. DETAIL APPLIES TO ALL EXPANSION JOINTS FOR THE UNDERGROUND CONCRETE ENCASED CONDUITS. PVC CONDUIT INSTALLATIONS SHALL HAVE 18 INCHES MIN LENGTH OF RGS CONDUIT EACH SIDE OF FITTING. PREMOLDED JOINT FILLER AT CONSTRUCTION JOINT 3 / 4 " PLUG COUPLING CONDUIT FINISHED FLOOR NOTES: CONDUITS WHICH ARE STUBBED UP IN A CONCRETE SLAB FOR FUTURE EXTENSION SHALL BE INSTALLED IN ACCORDANCE WITH THIS DETAIL. 1. WALL BUSHING FLOOR 2"2" SCHEDULE 80 PVC SPACER, SEE NOTE SILICON BRONZE BOLTS, NUTS AND WASHERS. SIZE TO SUIT, TYP NON-METALLIC CONDUIT GROUND CABLE (SIZE AS SHOWN ON DRAWING) GROUND BUS, HARD DRAWN COPPER BAR 3/8" THICK PLAN ELEVATION NOTES: MAXIMUM SPAN BETWEEN SUPPORTS NOT TO EXCEED 24".1. GROUND CABLE CONNECTOR EXOTHERMIC WELD TO CABLE 5/8" MIN CONCRETE ANCHOR, SEE NOTE 1 LENGTH OF SUIT 2 " 3 " 3/4" VA RIES 2 " 6 " 2 1/2" 4" 4" 3/4" BEND AROUND CORNERS AS REQUIRED GROUND CABLE TO SERVICE EQUIPMENT GROUND CLAMP, DEVICE LOCATION INSTALL NEAR SERVICE ENTRANCE TIE TOGETHER AND EMBED IN FOUNDATION BOTTOM OF FOUNDATION 1/2" (#4 MIN) REBAR TOP OF FOUNDATION 1'-0" MIN 20' LONG MIN, 2 TYP 2 " 1 3/4" 1. 2. GROUNDING ELECTRODECONDUCTORS, BARE COPPERSIZE AS SHOWN ON DRAWINGS TOP OF GROUND ROD SHALL BE SAND BEDDED 6" MIN BELOW GRADE. CONNECTIONS TO EXISTING GROUNDING ELECTRODE CONDUCTORS SHALL BE CADWELD OR EQUIVALENT. EXOTHERMIC WELDED CONNECTION (CADWELD OR EQUIVALENT) NOTES: COPPER CLAD GROUND ROD PROVIDE A PVC SLEEVE AND FILL WITH A SUITABLE PLASTIC EXPANDABLE COMPOUND WHERE CONDUIT PASSES THROUGH SLAB CONDUIT. FOR TYPE REQUIRED, SEE SPECIFICATIONS NOTES: ALL CONDUITS THROUGH CONCRETE FLOOR SLABS AND EQUIPMENT PADS SHALL BE INSTALLED IN ACCORDANCE WITH THIS DETAIL. 1. CONDUIT OU T S I D E DI A M E T E R GALVANIZED STEEL SHEET METAL ESCUTCHEON, TYP INSULATION AS REQUIRED TO FILL CAVITY OF C O N D U I T PL U S 1 " , M I N NOTES: 1.CONDUITS WHICH INDIVIDUALLY PASS THRU AN INTERIOR WALL SHALL BE INSTALLED IN ACCORDANCE WITH THIS DETAIL. IF WALL IS A FIRE WALL, FILL CAVITY WITH FIRE STOP SEALANT AS SPECIFIED. GALVANIZED STEEL PIPE SLEEVE OR CORE DRILLED HOLE IN CONCRETE WALL OSHA/NEC PLACARD MANUFACTURER'S NAMEPLATE(S) NOTES: SUBMIT FINAL DESIGN AND CALCULATIONS FOR SUPPORT AND ANCHORAGE AS SPECIFIED. 1. EQUIPMENT PAD MIN 4 3/4" DIA CONC ANCHORS. SEE NOTE 4'-0" PIGTAIL, TYP 1. 2. SIZE OPENINGS AS REQUIRED BY TRANSFORMER OR SWITCH MANUFACTURER GROUND ROD, TYP GROUND CONDUCTOR, TYP GROUNDING LOOP AS SHOWN ON PLANS, TYP CONDUITS AS REQUIRED, TYP TRANSFORMER OR SWITCH FOOTPRINT PLAN NOTES: COORDINATE ALL FINAL PAD DIMENSIONS WITH THE ELECTRICAL UTILITY OR MANUFACTURER'S APPROVED SHOP DRAWINGS. SUBMIT FINAL DESIGN AND CALCULATIONS FOR SUPPORT AND ANCHORAGE AS SPECIFIED. EQUIPMENT PAD, TYPE XXX 1'-0" MIN 1' - 0 " M I N 4'-0" MIN 1' - 0 " M I N CONDUIT D = 3" MIN FOR 2" AND LARGER CONDUIT D = 2" MIN FOR 1 1/2" AND SMALLER CONDUIT FINISH GRADE SEE TRENCH AC TOPPING DETAIL (IF APPLICABLE) COMPACTED EARTH BACKFILL COMPACTED BEDDING AND PIPE ZONE MATERIAL (2-DUCTS) 1'-2" MIN (1-DUCT) 8" MIN 3" M I N 3" M I N 36 " M I N ( > 6 0 0 V O L T S ) 24 " M I N ( < 6 0 0 V O L T S ) MIN 2" D MIN 2" 1 2 " WARNING TAPE 1.B1.C 11 ' - 0 " 2.2 2.1 11 ' - 0 " BUS TRAVEL DIRECTION 1600 mm [62.99"] 150 mm [5.91"]1300 mm [51.18"]150 mm [5.91"] 900 mm [35.43"] 75 mm [2.95"] CENTER OF SLOT IS REFERENCE DIMENSION FOR SHEET BT120-EPP231 GENERAL NOTES: 1. REFERENCE PANTOGRAPH INSTALLATION MANUAL FOR CABINET INSTALLATION AND TERMINATION OF WIRING. FRONT VIEW BOTTOM VIEW TOP/PLAN VIEW LEFT SIDE VIEW OPTION #1 (PREFERRED: ALL CABLES INCOMING AND/OR EXITING OPTION #2: CABLES INCOMING AND/OR EXITING WINDOW LOCATION AND SIZE FOR: DC POWER CABLES WINDOW LOCATION AND SIZE FOR: LOW VOLTAGE CABLE AND WIRE OPTION #1: CABLES INCOMING AND/OR EXITING WINDOW LOCATION AND SIZE FOR: LOW VOLTAGE CABLE AND WIRE 91.9 mm [3.62"]406.4 mm [16.00"] 76 mm [2.99"] 254 mm [10.00"] 63.3 mm [2.49"]279.4 mm [11.00"] 561.8 mm [22.12"] 203.2 mm [8.00"] 762 mm [30.00"] 50.6 mm [1.99"] 304.8 mm [12.00"] CL 1. REFERENCE PANTOGRAPH INSTALLATION MANUAL PRIOR TO INSTALLATION. NOTES: BACK VIEWRIGHT SIDE VIEW LEFT SIDE VIEW DC POS. CABLES IN/OUT, UPPER LEFT OF WINDOW 79.2 mm [3.12"] 203.2 mm [8.00"] 63.3 mm [2.49"]279.4 mm [11.00"] DC NEG. CABLES IN/OUT, LOWER RIGHT OF WINDOW 355.6 mm [14.00"] 380.9 mm [14.99"] 203.2 mm [8.00"] WINDOW LOCATION AND SIZE FOR: LOW VOLTAGE CABLE AND WIRE OPTION #2: CABLES INCOMING AND/OR EXITING DC POS. CABLES IN/OUT, TOP OF WINDOW DC NEG. CABLES IN/OUT, BOTTOM OF WINDOW 914.4 mm [36.00"] 101.5 mm [3.99"] 241.3 mm [9.50"] DC POS. CABLES IN/OUT, UPPER RIGHT OF WINDOW DC NEG. CABLES IN/OUT, LOWER LEFT OF WINDOW 79.2 mm [3.12"] 203.2 mm [8.00"] 279.4 mm [11.00"]63.3 mm [2.49"] CL 1. REFERENCE PANTOGRAPH INSTALLATION MANUAL PRIOR TO INSTALLATION. NOTES: 4' - 10 1/8" 2"2' - 10"1" _SEE STRUCTURAL DRAWING FOR FOUNDATION 6" BUS STATION PLATFORM CABINET FOUNDATION SEE STRUCTURAL DETAIL SHEET 1' - 0"1' - 2 1/2" 1 3/8" CONDUIT WELL CONDUIT TO COMM CABINETCONDUITS TO DEVICES 4' - 10 1/8" 2' - 2" 2' - 5" 6"6" _SEE STRUCTURAL DRAWING FOR FOUNDATION 6" CABINET FOUNDATION SEE STRUCTURAL DETAIL SHEET 6" 2' - 2" 6" 1' - 0" OPEN BOTTOM INSIDE FLANGES PLATFORM ELECTRICAL CONDUITS FOUNDATION CONTINUES FOR COMM CABINET CONDUIT TO COMM CABINET CABINET FOUNDATION PEDESTAL TO BE 6" HEIGHT. SEE STRUCTURAL SHEETS FOR FOUNDATION DETAIL CANOPY LIGHTING CABINETS GROUND ROD #6 AWG GROUND ROD #6 AWG COMPRESSION "C" CONNECTOR BURNDY TYPE 'GA-H' CONNECTOR NOTES: 1. GROUND FENCE POSTS CORNERS, ENDS, AND POSTS EVERY 160 FEET OF FENCELINE. 2. PROVIDE GROUNDING FOR FENCE POSTS ON EACH SIDE OF OVERHEAD POWER LINE. BURNDY TYPE 'GA-H' CONNECTOR (TYP) SCL OVERHEAD POWERLINE 42" UNDER ROADWAY 30" UNDER WALKWAY 9" 15 " 2' -0" CONCRETE COVER W/ RECESSED HANDHOLE. CONNECTOR, TWO CONDUCTORS TO GROUND ROD VITRIFIED CLAY PIPE, 12" I.D BARE COPPER SIZED PER PLAN GROUND ROD EQUIPMENT ENCLOSURE #2/0 INSULATED CU. GROUND CONDUCTOR FINISHED FLOOR SLAB EXOTHERMIC CONNECTION TO GROUND LOOP 4" 24" MINIMUM BURNDY QIKLUG TERMINAL BOLTED TO EQUIPMENT FINISHED GRADE FOUNDATION 12 " M I N . EXOTHERMIC CONNECTION TO GROUND GRID PIPE RACK SUPPORT STEEL #4/0 BARE STRANDED COPPER GROUND CONDUCTOR EXOTHERMIC CONNECTION G G G G G G 1/0 BARE COPPER GROUND CONDUCTOR, TYP. COMPRESSION GROUND TYPICAL GROUND TAP CONNECTION CADWELD TYPE "LA" #4/0 BARE COPPER CABLE CADWELD TYPE "TA" #4/0 BARE COPPER CABLE CADWELD TYPE "RD" REBAR #4/0 BARE COPPER CABLE M M DPM DPM NEMA 3R, 3PH, 480/277V, 3000A, 65KAIC PSE UTILITY FEED BT120-T-101 PSE -KCM BEB CHARGING PAD MOUNTED TRANSFORMER SIZE TO BE DETERMINED BY PSE (8)4"C, 4#500 KCMIL CU PSE SECONDARY CONDUCTORS BT120-01A 150 KW POWER CABINET UTILITY CUSTOMER KCM-T-01 30KVA, 3PH 480V-208Y/120V STEP DOWN TRANSFORMER NEMA 3R KCM YARD PANEL KCM-PB2-01 208/120V 3P4W 100A MCB 22KAIC UTILITY METER N G 3/0 CU GEC 400/3 AF 250/3 AT 3000/3 BT120-01B 150 KW POWER CABINET BT120-02A 150 KW POWER CABINET BT120-02B 150 KW POWER CABINET BT120-03A 150 KW POWER CABINET BT120-03B 150 KW POWER CABINET 50/3 SPD 30/3 SPD 30/3 N G 3/0 CU GEC (FUTURE)KCM SWBD-02, NEMA 3R, 3PH, 480/277V, 3000A, 65KAIC PSE UTILITY FEED BT120-T-102 (FUTURE) PSE -KCM BEB CHARGING PAD MOUNTED TRANSFORMER SIZE TO BE DETERMINED BY PSEUTILITY CUSTOMER 3000/3 FUTURE 2ND BEB CHARGING SERVICE FOR FUTURE CHARGERS (8)4"C, FOR FUTURE PSE SECONDARY CONDUCTORS UTILITY METER YARD LIGHTING CONTROLLER BT120-LCP-03 116 117 114 114 114 114 114 114 KCM-SWBD-01 116 117 118118 131 BT120-N4-115 BT120-N4-116 BT120-N4-111 BT120-N4-112 BT120-N4-113 BT120-N4-114 BT120-N4-117 BT120-N2-101 400/3 AF 250/3 AT 400/3 AF 250/3 AT 400/3 AF 250/3 AT 400/3 AF 250/3 AT 400/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT HVC 300 CHARGER HVC 300 CHARGER HVC 300 CHARGER 600/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT 600/3 AF 250/3 AT KEY NOTES: G M M M 3 4 4 5 6 6 7 8 8 9 10 11 11 11 FEEDER SCHEDULE ID FEEDER AMPS CONDUIT AND FEEDER FEEDING THESE DEVICES 1 20 1/2"C,3#12,#12G FACP 2 60 1"C,3#4,#4N,#10G LCP, BT120-PB2-04 3 100 1-1/4"C,3#1,#8G BT120-T-02 4 100 1-1/2"C,3#1,#1N,#8G BT120-PB4-01, BT120-PB2-01, BT120-PB2-04, KCM-PB2-0451252"C,3#1/0,#1/0N,#6G BT120-PB2-05, BT120-PB2-06, KCM-T-02 6 175 2"C,3#2/0,#2/0N,#6G BT120-MBP-01, BT120-PB2-02 7 200 2"C,3#3/0,#3/0N,#6G BT120-PB2-03 8 200 2-1/2"C WITH PULLSTRING FUTURE BT120-SWBD-03, FUTURE BT120-ATS-02 9 250 2"C,3#250kcmil,#4G BT120-T-01 10 400 (2)2-1/2"C,3#3/0,#3/0N,#1/0G BT120-SWBD-02 11 400 (2)2-1/2"C,3#4/0,#4/0N,#2G BT120-ATS-01, BT120-SWBD-01 * SOME FEEDERS SIZES INCREASED FOR VOLTAGE DROP MITIGATION. CONTRACTOR RESPONSIBLE TO ENSURE WIRE BENDING SPACE AND TERMINATIONS ARE ADEQUATE DPM BT120-T-02 45kVA, 3PH 480V -208Y/120V STEP DOWN TRANSFORMER 70/3 EV PANEL BT120-SWGR-01, 480/277V, 3PH, 600A, 65kAIC BT120-GEN-01 300KW/375KVA 3PH, 480/277V STANDBY GENERATOR BT120-PB2-06 208V/120V 3P4W 125A MCB 22KAIC BT120-T-100 PSE -ST PAD MOUNTED TRANSFORMER SIZE TO BE DETERMINED BY PSEUTILITY CUSTOMER PSE UTILITY METER ST SERVICE SPD N G 60/3 400/3 400/3 400/3 200/3 N S BT120-ATS-01 480/277V 3PH 400A 4-POLE 200/3 250/3 BT120-SWBD-01, 480/277V, 3PH, 400A, 65kAIC 100/3 SITE LIGHTING & PERMANENT LOAD PANEL BT120-PB4-01 480/277V 3P4W 100A 22KAIC BT120-T-01 150kVA, 3PH 480V -208Y/120V STEP DOWN TRANSFORMER 400/3 BT120-SWBD-02, 208/120V, 3PH, 400A, 65kAIC 100/3 SECURITY PANEL BT120-PB2-01 208/120V 3P4W 100A 22KAIC 200/3 175/3 ST PANEL BT120-PB2-03 208/120V 3P4W 200A 22KAIC 175/3 BT120-MBP-01 20KW UPS TELE BT120-UPS-01 208/120V 3P 4W SCALABE UP TO 40KW ST UPS PANEL BT120-PB2-02 208/120V 3P4W 200A BUS 22KAIC 200/3 BT120-SWBD-03, 480/277V, 3PH, 200A, 65kAIC 200/3 N S BT120-ATS-02 480/277V 3PH 200A 4-POLE BT120-SWBD-04, 480/277V, 3PH, 200A, 42kAIC 90/3 90/3 BT120-EL-1 480V 3PH 40HP BT120-EL-2 480V 3PH 40HP LOCATE IN FUTURE GARAGE (ONE-LINE AS SHOWN FOR LOAD PURPOSE ONLY) 3/0 CU GEC 3/0 CU GEC PROVIDE SECONDARY FEEDER SIZE, QUANTITY AND WIRING METHOD AS REQUIRED PER PSE 125/3 M PSE UTILITY METER KCM SERVICE 14 12 KCM-T-02 75kVA 480V -208Y/120V STEP DOWN TRANSFORMER 100/2 KCM-PB2-02 208/120V 3P4W 200A BUS 200A MCB 22KAIC KCM PANEL 13 100/2 KCM-MBP-01 8KW UPS TELE KCM-UPS-1 208/120V 2P 3W SCALABE UP TO 16KW KCM PLATFOR M PANEL KCM-PB2-03 208/120V 2P3W 100A BUS 90A MCB 10KAIC 13 100/3 4 ST PLATFORM PANEL BT120-PB2-04 208/120V 3P4W 100A BUS 100A MCB 10KAIC 12 200 2"C,3#3/0,#3/0N,#4G KCM-PB2-02 13 100 1-1/2"C,2#1,#1N,#8G KCM-PB2-03, KCM-MBP-01 PLATFORM LIGHTING CONTROLLER BT120-LCP-02ELECTRICAL ROOM LIGHTING CONTROLLER BT120-LCP-01 100/3 KCM TELECOMM PANEL 4 KCM-PB2-04 208/120V 3P 4W 100A BUS 10KAIC 100/3 ST TELECOMM PANEL 4 BT120-PB2-05 208/120V 3P 4W 100A BUS 10KAIC 130 131 131 14 125 2"C, 3#1/0, #6G KCM-T-02 -/3 2" CONDUIT STUBBED TO ROOF AND CAPPED FOR SOLAR READINESS 600/3 MAIN BREAKER 1 KEY NOTES: DATA CABINET LINE TYPE LEGEND AC POWER (SIZE AS INDICATED) DC POWER (SIZE AS INDICATED) DATA & CONTROL E-STOP & INTERLOCK SPARE CONDUIT W/ PULL STRING (SIZE AS INDICATED) 1"C, CAT 6 PRIMARY BEB CHARGER AC UTILITY POWER TYPE 2, 4-C #14, #2 GND INTERLOCK CABLE TYPE 5, 2-PAIR #18 TSP COMMUNICATION CABLE TYPE GLASS FIBER, 8-FIBER OM3 DC POWER, 1500VDC, TYPE BEB (3"C, 2#250KCMIL) 3" SPARE CONDUIT SECONDARY BEB CHARGER PE C A B L E , # 2 G N D IN T E R L O C K & C A N C A B L E TY P E 5 , 3 -PA I R # 1 8 T S P KCM-SWBD-01 480V AC POWER 480V, 3PH, 3"C, 3#300KCMIL, #300KCMIL G AC POWER 480V, 3PH, 3"C, 3#300KCMIL, #300KCMIL G BEB ACM MODULE AC S H E A T E R C A B L E TY P E 1 , 3 -C # 1 4 AC S C P / P E C A B L E TY P E 1 , 2 -C # 1 4 AC S C O N T R O L C A B L E TY P E 1 , 8 -C # 1 4 DC P O W E R , 1 5 0 0 V D C PE C A B L E , 2 -C # 2 G N D TY P E B E B ( 2 ) 3 " C , 2 # 2 5 0 K C M I L E A C H E-STOP 1"C, 4-C #18 E-STOP BEB PANTOGRAPH JUNCTION BOX DC POWER, 1500VDC, TYPE BEB (3"C, 2#250KCMIL) IN SINGLE 2"C IN SINGLE 3"C MANUAL OPERATION TYPE 2, 10-C #18 MANUAL OPERATION PUSH BUTTON TYPE 2, 10-C #18 BT120-HH-SL-80 GENERAL NOTES: 1.SEE ILLUMINATION SHEETS BT120- CLS102 AND BT120-CLS103 FOR ILLUMINATION POLE SCHEDULE. SYMBOL LEGEND CIRCUIT IDENTIFIER LIGHT POLE NUMBER LUMINAIRE TYPE LUMINAIRE PULLBOX PULLBOX ID LP01 9,11 (LN-1) BT120-HH-SL 2"C, 4#10, 1#10G BT120-PB4-6,8,5,7 CKT LOADS: CKT 6,8 = 5.0KVA @ 480V, 1PH CKT 5,7 = 5.13KVA @ 480V, 1PH 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G LP15 6,8 (LN-1) 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G LP26 6,8 (LN-2) 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G LP14 6,8 (LN-1) LP13 6,8 (LN-2) LP18 6,8 (LN-1) LP09 5,7 (LN-1) LP19 5,7 (LN-1) LP08 5,7 (LN-1) BT120-HH-SL-15 BT120-HH-SL-26 BT120-HH-SL-18 BT120-HH-SL-13 BT120-HH-SL-19 BT120-HH-SL-08 BT120-HH-SL-14 BT120-HH-SL-09 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G LP12 6,8 (LN-1) LP20 5,7 (LN-1) LP07 5,7 (LN-1) BT120-HH-SL-12 BT120-HH-SL-20 BT120-HH-SL-07 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G LP11 6,8 (LN-2) LP21 5,7 (LN-1) LP06 5,7 (LN-1) BT120-HH-11 BT120-HH-SL-21 BT120-HH-SL-06 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G LP31 6,8 (LN-2) LP22 5,7 (LN-1) LP05 5,7 (LN-1) BT120-HH-SL-31 BT120-HH-SL-22 BT120-HH-SL-05 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G LP34 6,8 (LN-1) LP23 5,7 (LN-1) LP10 5,7 (LN-1) BT120-HH-SL-34 BT120-HH-SL-23 BT120-HH-SL-10 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G LP37 6,8 (LO) LP04 5,7 (LN-1) LP24 5,7 (LN-2) BT120-HH-SL-37 BT120-HH-SL-04 BT120-HH-SL-24 1"C , 2 #1 0, 1 #1 0 G 1"C, 2#10, 1#10G LP03 5,7 (LN-1) LP25 5,7 (LN-2) BT120-HH-SL-03 BT120-HH-SL-25 1"C, 2#10, 1#10G BT120-HH-SL-43 2"C, 6#10, 1#10G BT120-PB4-1,3,9,11,10,12 CKT LOADS: CKT 1,3 = 5.93KVA @ 480V, 1PH CKT 9,11 = 1.035KVA @ 480V, 1PH CKT 10,12 = 3.99KVA @ 480V, 1PH 2"C, 6#10, 1#10G 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G LP77 1,3 (LN-2) LP44 1,3 (LN-1) LP41 1,3 (LN-1) BT120-HH-SL-77 BT120-HH-SL-44 BT120-HH-SL-41 BT120-HH-SL-36 2"C, 2#10, 1#10GBT120-PB4-2,4 CKT LOADS: CKT 2,4 = 4.72KVA @ 480V, 1PH LP36 2,4 (LN-2) 1"C, 2#10, 1#10G LP17 2,4 (LN-2) BT120-HH-SL-17 1"C, 2#10, 1#10G LP57 2,4 (LN-2) BT120-HH-SL-57 1"C, 2#10, 1#10G LP82 2,4 (LN-2) BT120-HH-SL-82 1"C, 2#10, 1#10G LP50 2,4 (LN-2) BT120-HH-SL-50 1"C, 2#10, 1#10G LP16 2,4 (LN-2) BT120-HH-SL-16 1"C, 2#10, 1#10G LP40 2,4 (LN-1) BT120-HH-SL-40 LP52 2,4 (LN-2) BT120-HH-SL-52 1 " C , 2 # 1 0 , 1 # 1 0 G 1"C, 2#10, 1#10G LP39 2,4 (LN-1) BT120-HH-SL-39 1"C, 2#10, 1#10G LP35 2,4 (LN-2) BT120-HH-SL-35 LP43 1,3 (LN-2) 2"C, 6#10, 1#10G 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G LP76 1,3 (LO) LP45 1,3 (LN-1) BT120-HH-SL-76 BT120-HH-SL-45 BT120-HH-SL-58 2"C, 6#10, 1#10G LP46 1,3 (LN-2) BT120-HH-SL-46 1"C, 2#10, 1#10G BT120-HH-SL-56 LP56 1,3 (LN-1) 1"C, 2#10, 1#10G BT120-HH-SL-75 LP75 1,3 (LO) 2"C, 4#10, 1#10G LP47 10,12 (LN-2) BT120-HH-SL-47 1"C, 2#10, 1#10G BT120-HH-SL-83 LP83 1,3 (LN-1) 1"C, 2#10, 1#10G BT120-HH-SL-74 LP74 1,3 (LO) LP79 1,3 (LO) BT120-HH-SL-79 1" C , 2 # 1 0 , 1 # 1 0 G LP48 10,12 (LN-2) BT120-HH-SL-48 1"C, 2#10, 1#10G BT120-HH-SL-55 LP55 1,3 (LO) LP71 9,11 (LO) BT120-HH-SL-71 1" C , 2 # 1 0 , 1 # 1 0 G 1"C, 2#10, 1#10G LP02 10,12 (LN-1) BT120-HH-SL-02 1"C, 2#10, 1#10G BT120-HH-SL-54 LP54 1,3 (LO) LP72 9,11 (LO) BT120-HH-SL-72 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G LP30 10,12 (LN-1) BT120-HH-SL-30 1"C, 2#10, 1#10G BT120-HH-SL-53 LP53 1,3 (LN-1) LP73 9,11 (LO) BT120-HH-SL-73 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G LP29 10,12 (LN-2) BT120-HH-SL-29 1"C, 2#10, 1#10G BT120-HH-SL-51 LP51 1,3 (LN-1) LP01 9,11 (LN-2) BT120-HH-SL-01 1"C, 2#10, 1#10G 1"C, 2#10, 1#10G LP28 10,12 (LN-2) BT120-HH-SL-28 1"C, 2#10, 1#10G BT120-HH-SL-49 LP49 1,3 (LO) 1"C, 2#10, 1#10G LP42 10,12 (LN-2) BT120-HH-SL-42 1"C, 2#10, 1#10G LP27 10,12 (LN-1) BT120-HH-SL-27 1"C, 2#10, 1#10G 2"C, 4#10, 1#10G LP33 6,8 (LN-2) BT120-HH-SL-33 LP58 1,3 (LN-1) LP32 1,3 (LN-1) BT120-HH-SL-32 1" C , 2 # 1 0 , 1 # 1 0 G 1"C, 2#10, 1#10G BT120-HH-SL-38 LP38 1,3 (LO)1 1 1"C, 2#10, 1#10G LP85 6,8 (LN-2) BT120-HH-SL-85 LP86 10,12 (LN-1) BT120-HH-SL-86 1 " C , 2 # 1 0 , 1 # 1 0 G LP78 1,3 (LN-1) BT120-HH-SL-78 1" C , 2 # 1 0 , 1 # 1 0 G DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 1/ 2 7 / 2 0 2 5 1 1 : 3 2 : 3 4 A M BT120 0 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCN203 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS COMMUNICATIONS NOTESJMJDPPL ISSUED FOR BID12/10/2024 1.SEE COMMUNICATIONS NETWORK PLAN DWG BT120-JCP201 THROUGH BT120-JCP205 FOR NETWORK COMMUNICATIONS WORK OUTSIDE THE PLATFORM 2.SEE ELECTRICAL PLAN DWG BT120-EPP211 THROUGH BT120-EPP215 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK. 3.CONDUIT INSTALLATIONS SHALL COMPLY WITH NEC OR MANUFACTURER REQUIREMENTS, WHICHEVER IS STRICTER. 4.CONTRACTOR SHALL VERIFY DEPTH AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO THE START OF THE WORK SHOWN IN THE SYSTEM DRAWINGS. 5.COORDINATE CONDUIT ROUTING WITH STRUCTURAL FOUNDATIONS. 6.ALL CONDUIT INSTALLATIONS SHALL HAVE SPARE PULL STRINGS. SECURE PULL STRINGS TO JUNCTION BOX LID OR STRUCTURE 7.SEE DWG BT120-GZN001 THRU BT120-GZN007 FOR GENERAL SYMBOLS AND LEGEND. 8. THE COMMUNICATIONS CONDUIT INFRASTRUCTURE IS COMPRISED OF TWO DISTINCT AND PHYSICALLY SEPARATE SYSTEMS: ONE DESIGNATED FOR KING COUNTY METRO (KCM) AND THE OTHER FOR SOUND TRANSIT (ST). PROVIDE LABEL WITH THE RESPECTIVE OWNER'S IDENTIFICATION (ST OR KCM) IN ADDITION TO THE DISCIPLINE MARKER (COMM) TO ALL JUNCTION BOX LIDS. FOR DETAILED INFORMATION REGARDING THE SPECIFIC CONDUIT AND BOX ASSIGNMENTS, SEE DWGS BT120-JCP206 TO BT120-JCP212. 9. IN THE EVENT OF A CONFLICT IN THE DOCUMENTS LISTED, THE ORDER OF PRECEDENCE, WILL BE AS SET FORTH BELOW. IN CASE OF AN AMBIGUITY OR INCONSISTENCY BETWEEN ANY OF THE DOCUMENTS, THE HIGHER LISTED DOCUMENT SHALL TAKE PRECEDENCE OVER THE LOWER LISTED DOCUMENT: 1) CONTRACT DRAWINGS 2) TECHNICAL SPECIFICATIONS (DIVISIONS 02-34) 3) 2018 SOUND TRANSIT STANDARD SPECIFICATIONS, AMENDMENT 8 4) WSDOT PROJECT SPECIFIC SPECIAL PROVISIONS (PSSP) 5) WSDOT GENERAL SPECIAL PROVISIONS COMMUNICATIONS CONDUIT STUB-UP -COMMUNICATIONS CONDUIT SMART CARD READER (SCR) / WAYSIDE VALIDATOR CCTV CAMERA CANOPY VMS -KCM CANOPY VMS -STRIDE COMMUNICATIONS CABINET -STRIDE COMMUNICATIONS CABINET -KCM JUNCTION BOX WITH DECORATIVE COVER PUSH BUTTON AUDIO (PBA) TVM CABINET CUSTOMER EMERGENCY STATION (CES) CAM CAMERA CAT6 CATEGORY 6 CC CANOPY COLUMN CES CUSTOMER EMERGENCY STATION EPC EMBEDDED PERSONAL COMPUTER KCM KING COUNTY METRO PBA PUSH BUTTON AUDIO PIMS PASSENGER INFORMATION MANAGEMENT SYSTEM RTIS REAL TIME INFORMATION SIGNS SC SYSTEM CONDUIT ST SOUND TRANSIT COMMUNICATIONS SYMBOLS COMMUNICATIONS LABELS ABBREVIATIONS EQUIPMENT LABEL: INDICATES PROJECT ID INDICATES STATION NUMBER INDICATES WESTBOUND OR EASTBOUND DIRECTION INDICATES EQUIPMENT TYPE INDICATES EQUIPMENT NUMBER BTXXXD-DEVYYY CONDUIT LABEL: INDICATES PROJECT ID INDICATES STATION NUMBER INDICATES WESTBOUND OR EASTBOUND DIRECTION INDICATES SYSTEM CONDUIT INDICATES CONDUIT NUMBER BTXXXD-SC-YYY DESCRIPTION:SYMBOLS: GENERAL NOTES 585 RTA/CN 0205-24 01/25/2024 1.B 1.C 1.1 1.2 1.3 1.4 A BT120-JCX210 A BT120-JCE210 B BT120-JCX210 A BT120-JCE209 C BT120-JCX210 D BT120-JCX210 BT120-HH-101 BT120-DC-01 BT120-HH-103 BT120-HH-102 BT120-HH-104 10 BT120-SCR-01 (NIC) BT120-SCR-02 (NIC) 8 3 BT120-VMS-03 (NIC)7 12"C-BT120-SC-12 12"C-BT120-SC-11 1 2"C-BT120-SC-103 1 2"C-BT120-SC-106 1 2"C-BT120-SC-15 1 2"C-BT120-SC-108 13"C-BT120-SC-110 11"C-BT120-SC-111 12"C-BT120-SC-112 11"C-BT120-SC-113 11"C-BT120-SC-114 12"C-BT120-SC-115 1 3"C-BT120-SC-104 11"C-BT120-SC-109 2 10 10 310 1 2"C-BT120-SC-14 1 2"C-BT120-SC-105 12"C-BT120-SC-10 12"C-BT120-SC-13 1 2"C-BT120-SC-154 6BT120-TVM-01 (NIC) 4 BT120-CC-02 4 BT120-CC-03 9 LIGHT POLE 10 24' - 0"24' - 0"24' - 0" 4' - 3 " 13' - 0" 1' - 7 " 12' - 1" 12' - 0"5' - 0 " 4' - 0 " 12' - 0" 19' - 0" 3' - 6" 11 " 2' - 8" 5" 2' - 9" 2' - 5 " 19' - 0" BT120-CAM-1009 5 1.A 1 2"C-BT120-SC-220 12"C-BT120-SC-221 2' - 7 " BT120-PBA-01 (NIC) CONDUIT AND WIRING SCHEDULE CONDUIT TAG EQUIPMENT CONDUIT SIZE WIRE TYPE REMARK FROM TO BT120-SC-10 BT120-HH-03 BT120-HH-102 2" PVC 1-12SMFO ST BT120-SC-11 BT120-HH-03 BT120-HH-102 2" PVC ST BT120-SC-12 BT120-HH-04 BT120-HH-102 2" PVC 4-CAT6 ST BT120-SC-13 BT120-HH-04 BT120-HH-102 2" PVC ST BT120-SC-14 BT120-HH-103 BT120-HH-09 2" PVC 1-CAT6 ST BT120-SC-15 BT120-HH-103 BT120-HH-09 2" PVC ST BT120-SC-103 BT120-DC-01 BT120-HH-102 2" PVC 1-12SMFO ST BT120-SC-104 BT120-DC-01 BT120-HH-101 3" PVC 4-CAT6 ST BT120-SC-105 BT120-DC-01 BT120-HH-103 2" PVC 7-CAT6 ST BT120-SC-106 BT120-HH-103 LIGHT POLE 10 2" PVC 1-CAT6 ST BT120-SC-108 BT120-HH-103 BT120-CC-02 2" PVC 4-CAT6 ST BT120-SC-109 BT120-HH-101 BT120-SCR-01 1" PVC ST BT120-SC-110 BT120-HH-101 BT120-HH-104 3" PVC 5-CAT6 ST BT120-SC-111 BT120-HH-104 BT120-TVM-01 1" PVC ST BT120-SC-112 BT120-HH-104 BT120-HH-202 2" PVC 2-CAT6 ST BT120-SC-113 BT120-HH-104 BT120-SCR-02 1" PVC ST BT120-SC-114 BT120-HH-104 BT120-PBA-01 1" PVC 1-CAT6 ST BT120-SC-115 BT120-HH-104 BT120-VMS-03 2" PVC 2-CAT6 ST BT120-SC-154 BT120-DC-01 BT120-HH-102 2" PVC 4-CAT6 ST BT120-SC-220 BT120-DC-01 BT120-HH-101 2" PVC ST BT120-SC-221 BT120-HH-104 BT120-HH-101 2" PVC ST N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 20 2 5 - 0 7 - 0 1 1 : 5 8 : 0 5 P M BT120 2 S1-BT120-J-CAN-v2020 RTA/CN 0205-24 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER S.WHITE M.COX STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCP206 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS STRIDE BAY 1 COMMUNICATIONS PLANJMSWMC JM SW MC JM SW MC 12/10/2024 586ISSUED FOR BID BAY 1 INSTALL ALL CONDUIT ABOVE FOUNDATION OF SHELTER, SEE STRUCTURAL PLAN SHEETS BT120-SFP212 TO BT120-SFP215 FOR DETAILS. MAINTAIN A 2" MINIMUM CLEARANCE ABOVE FOUNDATION. INSTALL ST COMMUNICATIONS CABINET AND CABINET FOUNDATION. SEE DETAIL ON DWG BT120-JCD208. SEE DWG BT120-SGY403 FOR STRUCTURAL DETAILS. STUB UP CONDUIT. WAYSIDE VALIDATOR/SMART CARD READER POST INSTALLED BY OTHERS. SEE DETAIL ON DWG BT120-JCD206. STUB UP CONDUIT INTO THE DESIGNATED CHANNEL ON THE COLUMN, WHICH VARIES DEPENDING ON THE CONDUIT ROUTING RELATIVE TO THE CANOPY'S LOWER OR HIGHER SIDE. ENSURE CONDUITS STUB UP AT CORRECT LOCATION AND SIDE. SEE DWG BT120- JCX210 TO BT120-JCX212 AND BT120-AED903 FOR MORE DETAILS. SEE BT120-JCE209 TO BT120-JCE216 FOR VERTICAL CONTINUATION. STUB UP CONDUIT INTO CABINET FOUNDATION. SEE DETAIL ON DWG BT120-JCD207. STUB UP CONDUIT. TVM INSTALLED BY OTHERS. SEE DETAIL ON DWG BT120-JCD206. STUB UP CONDUIT. PYLON VMS INSTALLED BY OTHERS. SEE DETAIL ON DWG BT120- JCD206. STUB UP CONDUIT INTO PBA POLE. PBA INSTALLED BY OTHERS. SEE DETAIL ON DWG BT120-JCD204. STUB UP CONDUIT INTO LIGHT POLE FOUNDATION. SEE DWG BT120-CLP201 FOR LIGHT POLE INSTALLATION. INSTALL CAMERAS AND ASSOCIATED CABLING, SEE DWG BT120- JCD202 FOR INSTALL DETAILS. INSTALL TYPE 2 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.10-04 WITH DECORATIVE LID. STUB UP CONDUIT TO JUNCTION BOX. DIMENSION ON PLAN IS TO THE CENTERLINE OF THE BOX. BOX WILL BE LOCATED CENTERED ON THE LID. SEE DETAIL ON DWG BT120-JCD207 FOR CONDUIT ROUTING DETAILS. CONSTRUCTION NOTES: 1 2 3 4 5 6 7 8 9 10 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE IN FEET 4 0 88 16 MA T C H L I N E : SE E D W G B T 1 2 0 -JC P 2 0 7 MATCHLINE: SEE DWG BT120-JCP201 MATCHLINE: SEE DWG BT120-JCP201 1 06/13/2025 ADDENDUM #1 2 06/27/2025 ADDENDUM #2 2 1 2 2 07/01/2025 2.D2.E 2.B1.E 1.D 1.F 1.5 1.6 1.7 1.A 1.B 1.C A BT120-JCE211 B BT120-JCX212 C BT120-JCX212 A BT120-JCX212 BT120-HH-107 BT120-HH-108 BT120-HH-10610 BT120-DC-03 BT120-DC-02 BT120-SCR-03 (NIC) 10 BT120-SCR-04 (NIC) 3 BT120-VMS-04 (NIC) BT120-HH-105 1 2"C-BT120-SC-133 1 1"C-BT120-SC-135 1 1"C-BT120-SC-136 1 2"C-BT120-SC-132 7 12"C-BT120-SC-131 11"C-BT120-SC-130 12 10 2 10 12"C-BT120-SC-127 11"C-BT120-SC-122 12"C-BT120-SC-121 13"C-BT120-SC-126 12"C-BT120-SC-28 12"C-BT120-SC-125 6BT120-TVM-02 (NIC) 12"C-BT120-SC-12012"C-BT120-SC-134 12"C-BT120-SC-123 12"C-BT120-SC-30 11"C-BT120-SC-129 12"C-BT120-SC-29 12"C-BT120-SC-31 3 8 4BT120-CC-05 4 BT120-CC-06 24' - 0"24' - 0" 15 ' - 0 " 15 ' - 0 " 12' - 0" 4' - 6 " 2' - 0" 2' - 3 " 2' - 6 " 14' - 1" 9' - 1 1 " 13 ' - 3 " 1' - 7 " 8' - 8" 1' - 9 " A BT120-JCE212 11"C-BT120-SC-155 BT120-HH-120 10 12"C-BT120-SC-2013' - 3" 7' - 7" 5 12"C-BT120-SC-200 1 2"C-BT120-SC-222 12"C-BT120-SC-223 BT120-PBA-02 (NIC) 5' - 11" CONDUIT AND WIRING SCHEDULE CONDUIT TAG EQUIPMENT CONDUIT SIZE WIRE TYPE REMARK FROM TO BT120-SC-28 BT120-HH-07 BT120-HH-106 2" PVC 2-12SMFO ST BT120-SC-29 BT120-HH-07 BT120-HH-106 2" PVC ST BT120-SC-30 BT120-HH-08 BT120-HH-107 2" PVC 2-12SMFO KCM BT120-SC-31 BT120-HH-08 BT120-HH-108 2" PVC KCM BT120-SC-120 BT120-DC-03 BT120-HH-108 2" PVC 3-CAT6 KCM BT120-SC-121 BT120-HH-108 BT120-HH-109 2" PVC 1-12SMFO KCM BT120-SC-122 BT120-HH-108 BT120-PBA-03 1" PVC KCM BT120-SC-123 BT120-HH-108 BT120-HH-206 2" PVC 2-CAT6 KCM BT120-SC-125 BT120-DC-02 BT120-HH-107 2" PVC 9-CAT6 ST BT120-SC-126 BT120-DC-02 BT120-HH-106 3" PVC 1-12SMFO ST BT120-SC-127 BT120-HH-106 BT120-HH-110 2" PVC 1-12SMFO ST BT120-SC-129 BT120-DC-02 BT120-SCR-04 1" PVC 1-CAT6 ST BT120-SC-130 BT120-HH-107 BT120-TVM-02 1" PVC 1-CAT6 ST BT120-SC-131 BT120-HH-107 BT120-HH-207 2" PVC 4-CAT6 ST BT120-SC-132 BT120-HH-107 BT120-HH-105 2" PVC 5-CAT6 ST BT120-SC-133 BT120-HH-105 BT120-HH-204 2" PVC 2-CAT6 ST BT120-SC-134 BT120-HH-105 BT120-VMS-04 2" PVC 2-CAT6 ST BT120-SC-135 BT120-HH-105 BT120-SCR-03 1" PVC 1-CAT6 ST BT120-SC-136 BT120-HH-105 BT120-PBA-02 1" PVC 1-CAT6 ST BT120-SC-155 BT120-DC-03 BT120-HH-108 1" PVC 1-12SMFO KCM BT120-SC-200 BT120-DC-03 BT120-HH-120 2" PVC 2-CAT6 KCM BT120-SC-201 BTR120-HH-120 BT120-HH-109 2" PVC 2-CAT6 KCM BT120-SC-222 BTR120-HH-105 BT120-HH-107 2" PVC 1-CAT6 ST BT120-SC-223 BTR120-DC-02 BT120-HH-107 2" PVC 2-CAT6 ST N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 20 2 5 - 0 6 - 0 6 1 : 1 0 : 1 2 P M As indicated BT120 S1-BT120-J-CAN-v2020 RTA/CN 0205-24 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER S.WHITE M.COX STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCP207 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS STRIDE BAY 2 AND 8 COMMUNICATIONS PLANJM SW MC JM SW MC 12/10/2024 587ISSUED FOR BID BAY 8 BAY 2 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N INSTALL ALL CONDUIT ABOVE FOUNDATION OF SHELTER, SEE STRUCTURAL PLAN DWG BT120-SFP212 TO BT120-SFP215 FOR DETAILS. MAINTAIN A 2" MINIMUM CLEARANCE ABOVE FOUNDATION. INSTALL ST COMMUNICATIONS CABINET AND CABINET FOUNDATION. SEE DETAIL ON DWG BT120-JCD208. SEE DWG BT120-SGY403 FOR STRUCTURAL DETAILS. STUB UP CONDUIT. WAYSIDE VALIDATOR/SMART CARD READER POST INSTALLED BY OTHERS. SEE DETAIL ON DWG BT120-JCD206. STUB UP CONDUIT INTO THE DESIGNATED CHANNEL ON THE COLUMN, WHICH VARIES DEPENDING ON THE CONDUIT ROUTING RELATIVE TO THE CANOPY'S LOWER OR HIGHER SIDE. ENSURE CONDUITS STUB UP AT CORRECT LOCATION AND SIDE. SEE DWG BT120- JCX210 TO BT120-JCX212 AND BT120-AED903 FOR MORE DETAILS. SEE BT120-JCE209 TO BT120-JCE216 FOR VERTICAL CONTINUATION. STUB UP CONDUIT INTO CABINET FOUNDATION. SEE DETAIL ON DWG BT120-JCD207. STUB UP CONDUIT. TVM INSTALLED BY OTHERS. SEE DETAIL ON DWG BT120-JCD206. STUB UP CONDUIT. PYLON VMS INSTALLED BY OTHERS. SEE DETAIL ON DWG BT120- JCD206. STUB UP CONDUIT INTO PBA POLE. PBA INSTALLED BY OTHERS. SEE DETAIL ON DWG BT120-JCD204. INSTALL TYPE 2 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.10-04 WITH DECORATIVE LID. STUB UP CONDUIT TO JUNCTION BOX. DIMENSION ON PLAN IS TO THE CENTERLINE OF THE BOX. BOX WILL BE LOCATED CENTERED ON THE LID. SEE DETAIL ON DWG BT120-JCD207 FOR CONDUIT ROUTING DETAILS. INSTALL KCM COMMUNICATIONS CABINET AND CABINET FOUNDATION. SEE DETAIL ON DWG BT120-JCD208.SEE DWG BT120-SGY403 FOR STRUCTURAL DETAILS. CONSTRUCTION NOTES: 1 2 3 4 5 6 7 8 10 12 SCALE IN FEET 4 0 88 16 MA T C H L I N E : SE E D W G B T 1 2 0 -JC P 2 0 6 MA T C H L I N E : SE E D W G B T 1 2 0 -JC P 2 0 8 MATCHLINE: SEE DWG BT120-JCP201 1 1 06/13/2025 ADDENDUM #1 1 1 06/10/2025 2.D 2.E 1.E 1.D 1.F 1.151.141.131.121.111.101.91.8 A BT120-JCX211 B BT120-JCX211 D BT120-JCX211 C BT120-JCX211 BT120-HH-10910 BT120-HH-110 10BT120-HH-111 10 BT120-DC-05 10 BT120-DC-04 12 12"C-BT120-SC-147 12"C-BT120-SC-146 12"C-BT120-SC-143 12"C-BT120-SC-141 12"C-BT120-SC-152 11"C-BT120-SC-151 12"C-BT120-SC-150 12"C-BT120-SC-139 1 2"C-BT120-SC-127 1 2"C-BT120-SC-121 1 2"C-BT120-SC-137 1 2"C-BT120-SC-138 12"C-BT120-SC-144 11"C-BT120-SC-142 12"C-BT120-SC-148 BT120-HH-112 12"C-BT120-SC-149 11"C-BT120-SC-140 12"C-BT120-SC-145 BT120-HH-113 12"C-BT120-SC-153 12"C-BT120-SC-37 12"C-BT120-SC-36 2 1011"C-BT120-SC-204 4BT120-CC-08 4BT120-CC-12 4BT120-CC-14 4BT120-CC-15 A BT120-JCE214 24' - 0"24' - 0"24' - 0"24' - 0" 24' - 0" 24' - 0"24' - 0" 3' - 8 " 13' - 6" 12' - 0" 3' - 1 " 4' - 6 " 2' - 9 " 1' - 5 " 1' - 5 " 12"C-BT120-SC-156 12"C-BT120-SC-157 1 2"C-BT120-SC-201 BT120-HH-12110 1 2"C-BT120-SC-202 12"C-BT120-SC-203 4' - 0 " 5 4BT120-CC-13 A BT120-JCE216 A BT120-JCE213 1 CONDUIT AND WIRING SCHEDULE CONDUIT TAG EQUIPMENT CONDUIT SIZE WIRE TYPE REMARKFROMTO BT120-SC-36 BT120-HH-113 BT120-HH-11 2" PVC 1-CAT6 ST BT120-SC-37 BT120-HH-113 BT120-HH-11 2" PVC 1-CAT6 ST BT120-SC-121 BT120-HH-109 BT120-HH-108 2" PVC 1-12SMFO KCM BT120-SC-127 BT120-HH-106 BT120-HH-110 2" PVC 1-12SMFO ST BT120-SC-137 BT120-HH-109 BT120-HH-216 2" PVC 2-CAT6 KCM BT120-SC-138 BT120-HH-109 BT120-HH-121 2" PVC 1-12SMFO KCM BT120-SC-139 BT120-HH-111 BT120-HH-211 2" PVC 2-CAT6 KCM BT120-SC-140 BT120-HH-111 BT120-PBA-06 1" PVC KCM BT120-SC-141 BT120-HH-111 BT120-DC-04 2" PVC 2-CAT6 KCM BT120-SC-142 BT120-HH-113 BT120-CES-01 1" PVC 1-CAT6 ST BT120-SC-143 BT120-HH-111 BT120-HH-114 2" PVC KCM BT120-SC-144 BT120-HH-110 BT120-HH-213 2" PVC 2-CAT6 ST BT120-SC-145 BT120-HH-110 BT120-DC-05 2" PVC 5-CAT6 ST BT120-SC-146 BT120-HH-110 LIGHT POLE 26 2" PVC 2-CAT6 ST BT120-SC-147 BT120-HH-110 LIGHT POLE 27 2" PVC 2-CAT6 ST BT120-SC-148 BT120-DC-05 BT120-HH-220 2" PVC 2-CAT6 ST BT120-SC-149 BT120-DC-04 BT120-HH-112 2" PVC 4-CAT6 KCM BT120-SC-150 BT120-HH-112 BT120-HH-209 2" PVC 4-CAT6 KCM BT120-SC-151 BT120-HH-112 BT120-PBA-05 1" PVC KCM BT120-SC-152 BT120-DC-05 BT120-HH-113 2" PVC 1-CAT6 ST BT120-SC-153 BT120-DC-05 BT120-HH-113 2" PVC 1-CAT6 ST BT120-SC-156 BT120-HH-121 BT120-DC-04 2" PVC 1-12SMFO KCM BT120-SC-157 BT120-HH-110 BT120-DC-05 2" PVC 1-12SMFO ST BT120-SC-201 BT-120-HH-120 BT120-HH-109 2" PVC 2-CAT6 KCM BT120-SC-202 BT120-HH-109 BT120-HH-121 2" PVC KCM BT120-SC-203 BT120-HH-121 BT120-DC-04 2" PVC KCM BT120-SC-204 BT120-HH-109 BT120-PBA-04 1" PVC KCM N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 20 2 5 - 0 7 - 0 1 1 : 5 3 : 4 1 P M As indicated BT120 2 S1-BT120-J-CAN-v2020 RTA/CN 0205-24 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER S.WHITE M.COX STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCP208 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS KCM BAYS 3, 6, AND 7 COMMUNICATIONS PLANJM SW MC JM SW MC JM SW MC 12/10/2024 588ISSUED FOR BID BAY 3 BAY 7 BAY 6 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N INSTALL ALL CONDUIT ABOVE FOUNDATION OF SHELTER, SEE STRUCTURAL PLAN DWG BT120-SFP212 TO BT120-SFP215 FOR DETAILS. MAINTAIN A 2" MINIMUM CLEARANCE ABOVE FOUNDATION. INSTALL ST COMMUNICATIONS CABINET AND CABINET FOUNDATION. SEE DETAIL ON DWG BT120-JCD208. SEE DWG BT120-SGY403 FOR STRUCTURAL DETAILS. STUB UP CONDUIT INTO THE DESIGNATED CHANNEL ON THE COLUMN, WHICH VARIES DEPENDING ON THE CONDUIT ROUTING RELATIVE TO THE CANOPY'S LOWER OR HIGHER SIDE. ENSURE CONDUITS STUB UP AT CORRECT LOCATION AND SIDE. SEE DWG BT120- JCX210 TO BT120-JCX212 AND BT120-AED903 FOR MORE DETAILS. SEE DWG BT120-JCE209 TO BT120-JCE216 FOR VERTICAL CONTINUATION. STUB UP CONDUIT INTO CABINET FOUNDATION. SEE DETAIL ON DWG BT120-JCD207. INSTALL TYPE 2 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.10-04 WITH DECORATIVE LID. STUB UP CONDUIT TO JUNCTION BOX. DIMENSION ON PLAN IS TO THE CENTERLINE OF THE BOX. BOX WILL BE LOCATED CENTERED ON THE LID. SEE DETAIL ON DWG BT120-JCD207 FOR CONDUIT ROUTING DETAILS. INSTALL KCM COMMUNICATIONS CABINET AND CABINET FOUNDATION. SEE DETAIL ON DWG BT120-JCD208. SEE DWG BT120-SGY403 FOR STRUCTURAL DETAILS. CONSTRUCTION NOTES: 1 2 4 5 10 12 SCALE IN FEET 4 0 88 16 MA T C H L I N E : SE E D W G B T 1 2 0 -JC P 2 0 7 MA T C H L I N E : SE E D W G B T 1 2 0 -JC P 2 0 9 MATCHLINE: SEE DWG BT120-JCP202 1 06/13/2025 ADDENDUM #1 2 06/27/2025 ADDENDUM #2 2 1 2 07/01/2025 1.E 1.F BT120-CES-0118 1 2"C-BT120-SC-146 1 2"C-BT120-SC-147 1 2"C-BT120-SC-143 1 1"C-BT120-SC-142 BT120-HH-114 1 1"C-BT120-SC-195 10 9 LIGHT POLE 259LIGHT POLE 24 10BT120-HH-115 1 2"C-BT120-SC-196 16' - 8" 10 ' - 0 " 4' - 5"15' - 6" 9" 10 ' - 0 " 59' - 8" BT120-CAM-1159 1.D 1.171.16 BT120-CAM-116 9 BT120-CAM-114 BT120-CAM-113 9 9 A BT120-JCE215 CONDUIT AND WIRING SCHEDULE CONDUIT TAG EQUIPMENT CONDUIT SIZE WIRE TYPE REMARKFROMTO BT120-SC-142 BT120-HH-113 BT120-CES-01 1" PVC 1-CAT6 ST BT120-SC-143 BT120-HH-111 BT120-HH-114 2" PVC KCM BT120-SC-146 BT120-HH-110 LIGHT POLE 24 2" PVC 2-CAT6 ST BT120-SC-147 BT120-HH-110 LIGHT POLE 25 2" PVC 2-CAT6 ST BT120-SC-195 BT120-HH-114 BT120-PBA-08 1" PVC KCM BT120-SC-196 BT120-HH-114 BT120-HH-115 2" PVC KCM N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 20 2 5 - 0 6 - 1 2 1 2 : 4 1 : 1 3 P M As indicated BT120 1 S1-BT120-J-CAN-v2020 RTA/CN 0205-24 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER S.WHITE M.COX STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCP209 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS KCM RAPID RIDE COMMUNICATIONS PLAN BAY 4 AND 5JMSWMC JM SW MC 12/10/2024 589ISSUED FOR BID BAY 4 BAY 5BAY 6 A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N INSTALL ALL CONDUIT ABOVE FOUNDATION OF SHELTER, SEE STRUCTURAL PLAN DWG BT120-SFP212 TO BT120-SFP215 FOR DETAILS. MAINTAIN A 2" MINIMUM CLEARANCE ABOVE FOUNDATION. STUB UP CONDUIT INTO LIGHT POLE. SEE DWG BT120-CLP202 FOR LIGHT POLE INSTALLATION. INSTALL CAMERAS AND ASSOCIATED CABLING, SEE DWG BT120-JCD209 FOR INSTALL DETAILS. INSTALL TYPE 2 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.10-04 WITH DECORATIVE LID. STUB UP CONDUIT TO JUNCTION BOX. DIMENSION ON PLAN IS TO THE CENTERLINE OF THE BOX. BOX WILL BE LOCATED CENTERED ON THE LID. SEE DETAIL ON DWG BT120-JCD207 FOR CONDUIT ROUTING DETAILS. STUB UP CONDUIT INTO CES. SEE DWG BT120-JCD204 FOR DEVICE DETAILS. SEE SHEET BT120-SGY403 FOR FOUNDATION INFO. INSTALL CES WITH EMERGENCY BUTTON FACING NORTH. CONSTRUCTION NOTES: 1 9 10 SCALE IN FEET 4 0 88 16 18 MA T C H L I N E : SE E D W G B T 1 2 0 -JC P 2 0 8 1 06/13/2025 ADDENDUM #1 1 1 06/10/2025 P 1.A 1.B 1.C 1.1 1.2 1.3 1.4 A BT120-JCX210 B BT120-JCX210 C BT120-JCX210 D BT120-JCX210 BT120-VMS-01 (NIC) BT120-VMS-02 (NIC) 13 1.5"C-BT120-SC-160 13 1"C-BT120-SC-161 16 131"C-BT120-SC-163 16 14 14 131"C-BT120-SC-162 16 16 131"C-BT120-SC-164 131"C-BT120-SC-165 13 1"C-BT120-SC-166 BT120-HH-201 BT120-HH-200 BT120-HH-202 BT120-HH-203 17 17 17 17 BT120-CAM-103 BT120-CAM-101 BT120-CAM-102 BT120-CAM-104 7' - 8 " BT120-CC-02 BT120-CC-03 7' - 8 " CONDUIT AND WIRING SCHEDULE CONDUIT TAG EQUIPMENT CONDUIT SIZE WIRE TYPE REMARK FROM TO BT120-SC-160 BT120-HH-200 BT120-HH-201 1.5" EMT 4-CAT6 ST BT120-SC-161 BT120-HH-201 BT120-CAM-101 1" EMT 1-CAT6 ST BT120-SC-162 BT120-HH-201 BT120-VMS-01 AND BT120-VMS-02 1" EMT 2-CAT6 ST BT120-SC-163 BT120-HH-201 BT120-CAM-102 1" EMT 1-CAT6 ST BT120-SC-164 BT120-HH-202 BT120-HH-203 1" EMT 2-CAT6 ST BT120-SC-165 BT120-HH-203 BT120-CAM-104 1" EMT 1-CAT6 ST BT120-SC-166 BT120-HH-203 BT120-CAM-103 1" EMT 1-CAT6 ST N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 20 2 5 - 0 6 - 1 2 1 2 : 4 2 : 0 4 P M As indicated BT120 1 S1-BT120-J-CAN-v2020 RTA/CN 0205-24 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER S.WHITE M.COX STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCP210 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS STRIDE BAY 1 SHELTER COMMUNICATIONS RCPJMSWMC JM SW MC 12/10/2024 590ISSUED FOR BID A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N INSTALL ALL CONDUIT INSIDE SHELTER STRUCTURE. COORDINATE EXACT ROUTING WITH ELECTRICAL AND LIGHTING. SECURE WITH CLAMP EVERY 10' AND WITHIN 3' OF JUNCTION BOXES. SEE DWG BT120-JCD210 FOR CONDUIT CLAMPING AND PENETRATION DETAILS. INSTALL CONDUIT AND CABLING FOR ST CANOPY VMS. COORDINATE WITH VMS INSTALLER FOR BRACKET ENCLOSURE AND DISPLAY UNIT INSTALLATION. SEE DETAIL 1 ON DWG BT120-JCD205 FOR DETAILED BREAKDOWN. INSTALL CANOPY CAMERA AND ALL ASSOCATED CABLING. SEE DETAIL ON DWG BT120- JCD205 FOR MOUNTING DETAILS. SEE SHEET BT120-JCD211 FOR CAMERA INSTALLATION SCHEDULE AND CONFIGURATION INFORMATION. CONFIGURE ALL CAMERAS AS SPECIFIED IN THE CAMERA INSTALLATION SCHEDULE ON DWG BT120-JCD211, ADHERING TO THE INDIVIDUAL SETTINGS FOR FOCAL LENGTH, ORIENTATION, AND OTHER PARAMETERS. CONTRACTOR SHALL ENSURE PROPER MOUNTING, WIRING, AND NETWORK INTEGRATION OF EACH CAMERA IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND PROJECT SPECIFICATIONS. INSTALL 5"x5" EMT CONDUIT JUNCTION BOX ATTACHED TO CANOPY STRUCTURE. SEE DETAIL 2 ON DWG JCD-210 FOR DETAILS. CONSTRUCTION NOTES: 13 14 16 SCALE IN FEET 4 0 88 16 17 1 06/13/2025 ADDENDUM #1 1 1 06/10/2025 2.B 1.E 1.D 1.F 1.5 1.6 1.7 1.A 1.B 1.C B BT120-JCX212 C BT120-JCX212 A BT120-JCX212 BT120-VMS-05 (NIC)BT120-VMS-06 (NIC) BT120-VMS-08 (NIC) BT120-VMS-07 (NIC) 16 14 14 16 131"C-BT120-SC-176 13 1"C-BT120-SC-172 13 1"C-BT120-SC-170 13 1"C-BT120-SC-174 16 16 15 15 13 1"C-BT120-SC-175 13 1"C-BT120-SC-171 131"C-BT120-SC-173 131"C-BT120-SC-177 BT120-CAM-105 BT120-CAM-107 BT120-HH-204 BT120-HH-20517 17 BT120-HH-206 BT120-CAM-106 17 BT120-HH-20717 BT120-HH-208 17 7' - 9 " 7' - 8 " BT120-CAM-108 CONDUIT AND WIRING SCHEDULE CONDUIT TAG EQUIPMENT CONDUIT SIZE WIRE TYPE REMARK FROM TO BT120-SC-170 BT120-HH-204 BT120-HH-205 1" EMT 2-CAT6 ST BT120-SC-171 BT120-HH-205 BT120-CAM-105 1" EMT 1-CAT6 ST BT120-SC-172 BT120-HH-205 BT120-CAM-106 1" EMT 1-CAT6 ST BT120-SC-173 BT120-HH-206 BT120-VMS-05 AND BT120-VMS-06 1" EMT 2-CAT6 KCM BT120-SC-174 BT120-HH-207 BT120-HH-208 1" EMT 4-CAT6 ST BT120-SC-175 BT120-HH-208 BT120-CAM-108 1" EMT 1-CAT6 ST BT120-SC-176 BT120-HH-208 BT120-VMS-07 AND BT120-VMS-08 1" EMT 2-CAT6 ST BT120-SC-177 BT120-HH-208 BT120-CAM-107 1" EMT 1-CAT6 ST N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 20 2 5 - 0 6 - 0 6 1 : 1 0 : 1 6 P M As indicated BT120 S1-BT120-J-CAN-v2020 RTA/CN 0205-24 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER S.WHITE M.COX STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCP211 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS KCM RAPID RIDE BAY 2 AND STRIDE BAY 8JM SW MC JM SW MC 12/10/2024 591ISSUED FOR BID A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE IN FEET 4 0 88 16 INSTALL ALL CONDUIT INSIDE SHELTER STRUCTURE. COORDINATE EXACT ROUTING WITH ELECTRICAL AND LIGHTING. SECURE WITH CLAMP EVERY 10' AND WITHIN 3' OF JUNCTION BOXES. SEE DWG BT120-JCD210 FOR CONDUIT CLAMPING AND PENETRATION DETAILS. INSTALL CONDUIT AND CABLING FOR ST CANOPY VMS. COORDINATE WITH VMS INSTALLER FOR BRACKET ENCLOSURE AND DISPLAY UNIT INSTALLATION. SEE DETAIL 1 ON DWG BT120-JCD205 FOR DETAILED BREAKDOWN. INSTALL CONDUIT AND CABLING FOR KCM CANOPY VMS. KCM DISPLAY MOUNT IS PROCURED BY KCM AND PROVIDED TO CONTRACTOR FOR INSTALLATION. DISPLAY UNITS ARE PROCURED AND INSTALLED BY KCM. SEE DETAIL 2 ON DWG BT120-JCD205 FOR DETAILED BREAKDOWN. INSTALL CANOPY CAMERA AND ALL ASSOCATED CABLING. SEE DETAIL ON SHEET BT120- JCD205 FOR MOUNTING DETAILS. SEE DWG BT120-JCD211 FOR CAMERA INSTALLATION SCHEDULE AND CONFIGURATION INFORMATION. CONFIGURE ALL CAMERAS AS SPECIFIED IN THE CAMERA INSTALLATION SCHEDULE ON DWG BT120-JCD211, ADHERING TO THE INDIVIDUAL SETTINGS FOR FOCAL LENGTH, ORIENTATION, AND OTHER PARAMETERS. CONTRACTOR SHALL ENSURE PROPER MOUNTING, WIRING, AND NETWORK INTEGRATION OF EACH CAMERA IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND PROJECT SPECIFICATIONS. INSTALL 5"x5" EMT CONDUIT JUNCTION BOX ATTACHED TO CANOPY STRUCTURE. SEE DETAIL 2 ON DWG BT120-JCD-210 FOR DETAILS. CONSTRUCTION NOTES: 13 14 15 16 17 CC-06 BT120- CC-05 1 1 06/13/2025 ADDENDUM #1 1 1 06/10/2025 1.E 1.D 1.F 1.151.141.131.121.111.101.91.8 A BT120-JCX211 B BT120-JCX211 D BT120-JCX211 C BT120-JCX211 131"C-BT120-SC-183 15 BT120-VMS-16 (NIC) 16 16 BT120-VMS-09 (NIC) BT120-VMS-10 (NIC) BT120-VMS-11 (NIC) BT120-VMS-12 (NIC) 15 15 15 15 15 BT120-VMS-14 (NIC) BT120-VMS-13 (NIC) 15 15 16 13 1"C-BT120-SC-194 13 1"C-BT120-SC-186 13 1"C-BT120-SC-193 131"C-BT120-SC-185 17BT120-HH-220 131"C-BT120-SC-182 17BT120-HH-219 131.5"C-BT120-SC-180 13BT120-SC-181 131"C-BT120-SC-187 17BT120-HH-211 13 BT120-SC-189 13 BT120-SC-191 13 BT120-SC-192 BT120-CAM-111 BT120-CAM-112 BT120-CAM-109 BT120-CAM-110 BT120-HH-209 BT120-HH-210 17 17 BT120-HH-21317 16 BT120-HH-217 17 7' - 8 " 131"C-BT120-SC-184 7' - 8 " BT120-HH-2183' - 0 " BT120-HH-215 17 BT120-VMS-15 (NIC) 15 BT120-HH-21617 BT120-HH-214 17 13BT120-SC-190 7' - 8 " 3' - 0 " 3' - 0 " BT120-CC-12 BT120-CC-14 CC-15 CONDUIT AND WIRING SCHEDULE CONDUIT TAG EQUIPMENT CONDUIT SIZE WIRE TYPE REMARK FROM TO BT120-SC-180 BT120-HH-209 BT120-HH-210 1.5" EMT 4-CAT6 KCM BT120-SC-181 BT120-HH-210 BT120-VMS-15 AND BT120-VMS-16 1" EMT 2-CAT6 KCM BT120-SC-182 BT120-HH-210 BT120-VMS-11 AND BT120-VMS-12 1" EMT 2-CAT6 KCM BT120-SC-183 BT120-HH-220 BT120-HH-218 1" EMT 2-CAT6 ST BT120-SC-184 BT120-HH-218 BT120-HH-219 1" EMT 2-CAT6 ST BT120-SC-185 BT120-HH-219 BT120-CAM-110 1" EMT 1-CAT6 ST BT120-SC-186 BT120-HH-219 BT120-CAM-109 1" EMT 1-CAT6 ST BT120-SC-187 BT120-HH-211 BT120-VMS-13 AND BT120-VMS-14 1" EMT 2-CAT6 KCM BT120-SC-189 BT120-HH-213 BT120-HH-214 1" EMT 2-CAT6 ST BT120-SC-190 BT120-HH-214 BT120-CAM-112 1" EMT 1-CAT6 ST BT120-SC-191 BT120-HH-214 BT120-HH-215 1" EMT 1-CAT6 ST BT120-SC-192 BT120-HH-215 BT120-CAM-111 1" EMT 1-CAT6 ST BT120-SC-193 BT120-HH-216 BT120-HH-217 1" EMT 2-CAT6 KCM BT120-SC-194 BT120-HH-217 BT120-VMS-09 AND BT120-VMS-10 1" EMT 2-CAT6 KCM N DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 20 2 5 - 0 6 - 0 6 1 : 1 0 : 1 8 P M As indicated BT120 S1-BT120-J-CAN-v2020 RTA/CN 0205-24 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER S.WHITE M.COX STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCP212 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS KCM COMMUNICATIONS RCP BAYS 3, 4, 6, AND 7JM SW MC JM SW MC 12/10/2024 592ISSUED FOR BID A B D KEY PLAN PLATFORM G H F E C GEN CORE FACILITY N SCALE IN FEET 4 0 88 16 INSTALL ALL CONDUIT INSIDE SHELTER STRUCTURE. COORDINATE EXACT ROUTING WITH ELECTRICAL AND LIGHTING. SECURE WITH CLAMP EVERY 10' AND WITHIN 3' OF JUNCTION BOXES. SEE DWG BT120-JCD210 FOR CONDUIT CLAMPING AND PENETRATION DETAILS. INSTALL CONDUIT AND CABLING FOR KCM CANOPY VMS. KCM DISPLAY MOUNT IS PROCURED BY KCM AND PROVIDED TO CONTRACTOR FOR INSTALLATION. DISPLAY UNITS ARE PROCURED AND INSTALLED BY KCM. SEE DETAIL 2 ON DWG BT120-JCD205 FOR DETAILED BREAKDOWN. INSTALL CANOPY CAMERA AND ALL ASSOCATED CABLING. SEE DETAIL ON SHEET BT120- JCD205 FOR MOUNTING DETAILS. SEE DWG BT120-JCD211 FOR CAMERA INSTALLATION SCHEDULE AND CONFIGURATION INFORMATION. CONFIGURE ALL CAMERAS AS SPECIFIED IN THE CAMERA INSTALLATION SCHEDULE ON DWG BT120-JCD211, ADHERING TO THE INDIVIDUAL SETTINGS FOR FOCAL LENGTH, ORIENTATION, AND OTHER PARAMETERS. CONTRACTOR SHALL ENSURE PROPER MOUNTING, WIRING, AND NETWORK INTEGRATION OF EACH CAMERA IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND PROJECT SPECIFICATIONS. INSTALL 5"x5" EMT CONDUIT JUNCTION BOX ATTACHED TO CANOPY STRUCTURE. SEE DETAIL 2 ON DWG BT120-JCD-210 FOR DETAILS. CONSTRUCTION NOTES: 13 15 16 17 BT120-CC-08 1 1 1 1 06/13/2025 ADDENDUM #1 1 1 06/10/2025 1.11.21.31.4 1 BT120-JCD206 2 BT120-JCD206 3 BT120-JCD206 BT120-VMS-03 (NIC) BT120-SCR-02 (NIC) BT120-SCR-01 (NIC) BT120-HH-103 BT120-CAM-102 BT120-CAM-101 BT120-PBA-01 (NIC) DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 2 9 P M NTS BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCE209 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS STRIDE BAY AREA 1 COMMUNICATIONS ELEVATIONJM JD PPL ISSUED FOR BID12/10/2024 SCALE: NTS BT120-JCP206 ELEVATION - STRIDE BAY AREA 1 A BT120-TVM-01 (NIC) BT120-VMS-01 (NIC) BT120-VMS-02 (NIC) 1. SEE ELECTRICAL PLAN DWG BT120-EPP212 TO BT120-EPP215 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET. 2. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE WHILE MAINTAINING 2" MINIMUM CLEARANCE FROM IT. 3. FOR UNDERGROUND CONDUITS, SEE DWG BT120-JCP206 TO BT120-JCP209. FOR CANOPY CONDUITS, SEE BT120-JCP210 TO BT120-JCP212. GENERAL NOTES: BT120-CC-03 BT120-CC-02 EXTEND CONDUIT WITHIN COLUMN COVER TO JUNCTION BOXES IN CANOPY SHOWN IN DWG BT120-JCP210 TO BT120-JCP212. 19 SYSTEMS CONDUIT19 CONSTRUCTION NOTES: 12/02/2024 0593 RTA/CN 0205-24 1.1 1.2 1.3 1.4 BT120-DC-01 BT120-HH-102 BT120-HH-104 BT120-CAM-103 BT120-CAM-104 DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 1/ 1 0 / 2 0 2 5 1 1 : 1 9 : 5 7 A M NTS BT120 0 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCE210 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS STRIDE LAYOVER COMMUNICATIONSJM JD PPL ISSUED FOR BID12/10/2024 SCALE: NTS BT120-JCP206 ELEVATION - STRIDE BAY AREA LAYOVER A 1. SEE ELECTRICAL PLAN DWG BT120-EPP212 TO BT120-EPP215 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET. 2. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE WHILE MAINTAINING 2" MINIMUM CLEARANCE FROM IT. 3. FOR UNDERGROUND CONDUITS, SEE DWG BT120-JCP206 TO BT120-JCP209. FOR CANOPY CONDUITS, SEE BT120-JCP210 TO BT120-JCP212. GENERAL NOTES: BT120-CC-03 EXTEND CONDUIT WITHIN COLUMN COVER TO JUNCTION BOXES IN CANOPY SHOWN IN DWG BT120-JCP210 TO BT120-JCP212. 19 SYSTEMS CONDUIT19 CONSTRUCTION NOTES: 594 RTA/CN 0205-24 01/25/2024 1.5 1.6 1.7 BT120-VMS-04 (NIC) BT120-SCR-03 (NIC) BT120-SCR-04 (NIC) BT120-DC-02 BT120-HH-107 BT120-HH-106 BT120-VMS-07 (NIC) BT120-VMS-08 (NIC) BT120-VMS-05 (NIC) BT120-VMS-06 (NIC) BT120-TVM-02 (NIC) BT120-CAM-108 BT120-CAM-107 BT120-PBA-02 (NIC) 1 DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 20 2 5 - 0 6 - 0 6 1 : 1 0 : 0 8 P M As indicated BT120 S1-BT120-J-CAN-v2020 RTA/CN 0205-24 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER S.WHITE M.COX STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCE211 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS STRIDE BAY 8 COMMUNICATIONS ELEVATIONJMSWMC JM SW MC 12/10/2024 595ISSUED FOR BID SCALE: NTS ELEVATION - STRIDE BAY AREA 8 A BT120-JCP208 1. SEE ELECTRICAL PLAN DWG BT120-EPP212 TO BT120-EPP215 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET. 2. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE WHILE MAINTAINING 2" MINIMUM CLEARANCE FROM IT. 3. FOR UNDERGROUND CONDUITS, SEE DWG BT120-JCP206 TO BT120-JCP209. FOR CANOPY CONDUITS, SEE BT120-JCP210 TO BT120-JCP212. GENERAL NOTES: BT120-CC-06 EXTEND CONDUIT WITHIN COLUMN COVER TO JUNCTION BOXES IN CANOPY SHOWN IN DWG BT120-JCP210 TO BT120-JCP212. 19 SYSTEMS CONDUIT19 SYSTEMS CONDUIT19 CONSTRUCTION NOTES: 1 06/13/2025 ADDENDUM #1 1 06/10/2025 1.51.61.7 BT120-HH-105 BT120-DC-03 BT120-HH-108 BT120-VMS-06 (NIC) BT120-VMS-05 (NIC) BT120-CAM-105 BT120-CAM-106 DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 3 1 P M NTS BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCE212 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS KCM BAY 2 COMMUNICATIONS ELEVATIONJM JD PPL ISSUED FOR BID12/10/2024 SCALE: NTS ELEVATION - KCM BAY 2 A BT120-JCP208 1. SEE ELECTRICAL PLAN DWG BT120-EPP212 TO BT120-EPP215 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET. 2. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE WHILE MAINTAINING 2" MINIMUM CLEARANCE FROM IT. 3. FOR UNDERGROUND CONDUITS, SEE DWG BT120-JCP206 TO BT120-JCP209. FOR CANOPY CONDUITS, SEE BT120-JCP210 TO BT120-JCP212. GENERAL NOTES: BT120-CC-07 BT120-CC-05 EXTEND CONDUIT WITHIN COLUMN COVER TO JUNCTION BOXES IN CANOPY SHOWN IN DWG BT120-JCP210 TO BT120-JCP212. 19 SYSTEMS CONDUIT19 SYSTEMS CONDUIT19 CONSTRUCTION NOTES: 12/02/2024 0596 RTA/CN 0205-24 1.111.101.91.8 BT120-HH-109 BT120-VMS-10 (NIC) BT120-VMS-09 (NIC) BT120-CAM-111 1.111.101.91.8 DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 3 1 P M As indicated BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCE213 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS KCM BAY 7 COMMUNICATIONS ELEVATIONJM JD PPL ISSUED FOR BID12/10/2024 1. SEE ELECTRICAL PLAN DWG BT120-EPP212 TO BT120-EPP215 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET. 2. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE WHILE MAINTAINING 2" MINIMUM CLEARANCE FROM IT. 3. FOR UNDERGROUND CONDUITS, SEE DWG BT120-JCP206 TO BT120-JCP209. FOR CANOPY CONDUITS, SEE BT120-JCP210 TO BT120-JCP212. GENERAL NOTES: BT120-CC-08 EXTEND CONDUIT WITHIN COLUMN COVER TO JUNCTION BOXES IN CANOPY SHOWN IN DWG BT120-JCP210 TO BT120-JCP212. 19 SYSTEMS CONDUIT19 CONSTRUCTION NOTES: SCALE: NTS ELEVATION - KC METRO SHELTER BAY 7 A 12/02/2024 0597 RTA/CN 0205-24 1.151.141.131.12 BT120-HH-110 BT120-VMS-13 (NIC) BT120-VMS-14 (NIC) BT120-CAM-112 1.151.141.131.12 DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 3 2 P M NTS BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCE214 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS KCM BAY 6 COMMUNICATIONS ELEVATIONJM JD PPL ISSUED FOR BID12/10/2024 SCALE: NTS ELEVATION - KC METRO SHELTER - BAY 6 A BT120-JCP208 1. SEE ELECTRICAL PLAN DWG BT120-EPP212 TO BT120-EPP215 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET. 2. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE WHILE MAINTAINING 2" MINIMUM CLEARANCE FROM IT. 3. FOR UNDERGROUND CONDUITS, SEE DWG BT120-JCP206 TO BT120-JCP209. FOR CANOPY CONDUITS, SEE BT120-JCP210 TO BT120-JCP212. GENERAL NOTES: BT120-CC-15BT120-CC-14BT120-CC-12 EXTEND CONDUIT WITHIN COLUMN COVER TO JUNCTION BOXES IN CANOPY SHOWN IN DWG BT120-JCP210 TO BT120-JCP212. 19 SYSTEMS CONDUIT19 SYSTEMS CONDUIT19 CONSTRUCTION NOTES: 12/02/2024 0598 RTA/CN 0205-24 1.16 1.171.171.16 1.171.16 BT120-HH-110 BT120-DC-05 BT120-CES-01 BT120-CAM-113 BT120-CAM-114 BT120-CAM-116 BT120-CAM-115 BT120-HH-115 BT120-HH-114 DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 1/ 1 0 / 2 0 2 5 1 1 : 1 9 : 5 9 A M 1/8" = 1'-0" BT120 0 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCE215 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS KCM BAYS 4 AND 5 COMMUNICATIONS ELEVATIONJM JD PPL ISSUED FOR BID12/10/2024 BAY 4 BAY 5 1. SEE ELECTRICAL PLAN DWG BT120-EPP212 TO BT120-EPP215 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET. 2. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE WHILE MAINTAINING 2" MINIMUM CLEARANCE FROM IT. GENERAL NOTES: SCALE: NTS ELEVATION - KC METRO BAY 4 AND 5 A BT120-JCP209 599 RTA/CN 0205-24 01/25/2024 1.15 1.14 1.13 1.12 1.11 1.10 1.9 1.81.15 1.14 1.13 1.12 1.11 1.10 1.9 1.8 BT120-VMS-16 (NIC) BT120-VMS-15 (NIC) BT120-VMS-11 (NIC) BT120-VMS-12 (NIC) BT120-CAM-110 BT120-CAM-109 1 DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 20 2 5 - 0 6 - 0 6 1 : 1 0 : 0 8 P M 1/8" = 1'-0" BT120 S1-BT120-J-CAN-v2020 RTA/CN 0205-24 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER S.WHITE M.COX STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCE216 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS KCM BAY 3 COMMUNICATIONS ELEVATIONJM SW MC JM SW MC 12/10/2024 600ISSUED FOR BID 1. SEE ELECTRICAL PLAN DWG BT120-EPP212 TO BT120-EPP215 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET. 2. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE WHILE MAINTAINING 2" MINIMUM CLEARANCE FROM IT. GENERAL NOTES: BT120-CC-15 BT120-CC-14 BT120-CC-13 SCALE: NTS KCM BAY 3 COMMUNICATIONS ELEVATION A BT120-JCP208 1 06/13/2025 ADDENDUM #1 1 06/10/2025 BT120-SCR-01 (NIC) BT120-CAM-103 BT120-CAM-101 9' - 0 " BT120-VMS-02 (NIC) BT120-VMS-01 (NIC) BT120-CAM-104 BT120-CAM-102 BT120-SCR-02 (NIC) DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 1/ 1 0 / 2 0 2 5 1 1 : 2 0 : 0 4 A M 1/4" = 1'-0" BT120 0 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCX210 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS COMMUNICATION STRIDE BAY 1 SECTIONSJM JD PPL ISSUED FOR BID12/10/2024 SCALE: 1/4" = 1'-0"BT120-JCP206 COMMUNICATIONS SECTION STRIDE BAY 1 CCTV A SCALE: 1/4" = 1'-0"BT120-JCP206 COMMUNICATIONS SECTION STRIDE BAY 1 VMS B BT120-TVM-01 (NIC) SCALE: 1/4" = 1'-0"BT120-JCP206 COMMUNICATIONS SECTION STRIDE BAY 1 TVM C SCALE: 1/4" = 1'-0"BT120-JCP206 COMMUNICATIONS SECTION STRIDE BAY 1 D BT120-CC-03 1. SEE ELECTRICAL PLAN DWG BT120-EPP213 TO BT120-EPP215 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET. 2. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE WHILE MAINTAINING 2" MINIMUM CLEARANCE FROM IT. 3. FOR UNDERGROUND CONDUITS, SEE DWG BT120-JCP206 TO BT120-JCP209. FOR CANOPY CONDUITS & DEVICES, SEE BT120-JCP210 TO BT120-JCP212. 4. REFER TO DWG BT120-JCD205 FOR CANOPY VMS/RTIS DETAIL. 5. REFER TO DWG BT120-JCD206 FOR SMART CARD READER DETAIL. 6. REFER TO DWG BT120-JCD204 FOR PBA DETAIL. GENERAL NOTES: 601 RTA/CN 0205-24 01/25/2024 9' - 0 " 3' - 0" BT120-VMS-12 (NIC) BT120-CAM-110 BT120-VMS-11 (NIC) 9' - 0 " 3' - 0" BT120-VMS-10 (NIC) BT120-VMS-09 (NIC) 9' - 0 " 8' - 0 " 3' - 0" 3' - 0" BT120-VMS-15 (NIC) BT120-VMS-16 (NIC) BT120-VMS-13 (NIC) BT120-VMS-14 (NIC) 3' - 4 " DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 20 2 5 - 0 6 - 0 6 1 : 1 0 : 1 8 P M 1/4" = 1'-0" BT120 S1-BT120-J-CAN-v2020 RTA/CN 0205-24 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER S.WHITE M.COX STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCX211 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS KCM COMMUNICATIONS SECTIONSJM SW MC JM SW MC 12/10/2024 602ISSUED FOR BID SCALE: 1/4" = 1'-0"BT120-JCE213 COMMUNICATIONS SECTION KCM VMS B SCALE: 1/4" = 1'-0"BT120-JCP208 COMMUNICATIONS SECTION KCM SHELTER A SCALE: 1/4" = 1'-0"BT120-JCP208 COMMUNICATIONS SECTION KCM BAY 6 D SCALE: 1/4" = 1'-0"BT120-JCP208 COMMUNICATIONS SECTION KCM & PBA SECTION C FUTURE KCM PBA. CAP CONDUIT 1. SEE ELECTRICAL PLAN DWG BT120-EPP213 TO BT120-EPP215 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET. 2. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE WHILE MAINTAINING 2" MINIMUM CLEARANCE FROM IT. 3. FOR UNDERGROUND CONDUITS, SEE DWG BT120-JCP206 TO BT120-JCP209. FOR CANOPY CONDUITS & DEVICES, SEE BT120-JCP210 TO BT120-JCP212. 4. REFER TO DWG BT120-JCD205 FOR CANOPY VMS/RTIS DETAIL. GENERAL NOTES: 1 1 1 1 1 06/13/2025 ADDENDUM #1 1 06/10/2025 8' - 1 " 9' - 0 " BT120-VMS-05 (NIC) BT120-VMS-06 (NIC) BT120-TVM-02 (NIC) BT120-VMS-08 (NIC) BT120-VMS-07 (NIC) BT120-CAM-106 BT120-SCR-03 (NIC) BT120-CAM-105 BT120-CAM-108 DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 20 2 5 - 0 6 - 0 6 1 : 1 0 : 1 8 P M 1/4" = 1'-0" BT120 S1-BT120-J-CAN-v2020 RTA/CN 0205-24 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER S.WHITE M.COX STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCX212 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS STRIDE BAY 2 AND 8 COMMUNICATIONS SECTIONSJM SW MC JM SW MC 12/10/2024 603ISSUED FOR BID SCALE: 1/4" = 1'-0"BT120-JCP207 COMMUNICATIONS SECTION KCM SHELTER BAY 2 B SCALE: 1/4" = 1'-0"BT120-JCP207 COMMUNICATIONS SECTION STRIDE BAY 8 C SCALE: 1/4" = 1'-0"BT120-JCP207 COMMUNICATIONS SECTION STRIDE BAY 2 AND SCR A KCM RTIS 1. SEE ELECTRICAL PLAN DWG BT120-EPP213 TO BT120-EPP215 FOR DESIGN OF CONDUITS AND BOXES SHOWN GREYED BACK ON THIS SHEET. 2. INSTALL ALL UNDERGROUND CONDUIT WITHIN STRUCTURE FOOTPRINT ABOVE FOOTING. INSTALL AS CLOSE TO THE SURFACE OF THE FOOTING AS FEASIBLE WHILE MAINTAINING 2" MINIMUM CLEARANCE FROM IT. 3. FOR UNDERGROUND CONDUITS, SEE DWG BT120-JCP206 TO BT120-JCP209. FOR CANOPY CONDUITS & DEVICES, SEE BT120-JCP210 TO BT120-JCP212. 4. REFER TO DWG BT120-JCD205 FOR CANOPY VMS/RTIS DETAIL. 5. REFER TO DWG BT120-JCD206 FOR SMART CARD READER DETAIL. 6. REFER TO DWG BT120-JCD204 FOR PBA DETAIL. GENERAL NOTES: 1 1 06/13/2025 ADDENDUM #1 1 1 1 06/10/2025 LEGEND: CAT6 CAT6 POE FIBER SPARE 2" CONDUIT PLATFORM COMMUNICATIONS CABINET BT120-DC-01 TYPE 2 JUNCTION BOX BT120-HH-102 2-2" CONDUIT BT120-SC-12, BT120-SC-13 2-2" CONDUIT BT120-SC-10, BT120-SC-11 TO BT120-HH-04 TO ST NETWORK RACK TELECOMM ROOM BT120L1208 BT120-HH-03 1-2" CONDUIT BT120-SC-154 1-2" CONDUIT BT120-SC-103 TYPE 2 JUNCTION BOX BT120-HH-103 TYPE 2 JUNCTION BOX BT120-HH-101 1-3" CONDUIT BT120-SC-104 1-2" CONDUIT BT120-SC-105 BT120-CAM-100 POLE-MOUNTED 1-2" CONDUIT BT120-SC-106 TO BT120-HH-09 2-2" CONDUIT BT120-SC-14, BT120-SC-15 CANOPY COLUMN STUB UP BT120-CC-02 1-2" CONDUIT BT120-SC-108 BT120-CAM-101 CANOPY-MOUNTED BT120-CAM-102 CANOPY-MOUNTED CANOPY VMS BT120-VMS-01 (NIC) EPC CANOPY VMS BT120-VMS-02 (NIC) EPC TYPE 2 JUNCTION BOX BT120-HH-104 NGORCA VALIDATOR BT102-SCR-01 (NIC) 1-3" CONDUIT BT120-SC-110 TVM BT120-TVM-01 (NIC) PYLON VMS BT120-VMS-03 (NIC) EPC NGORCA VALIDATOR BT102-SCR-02 (NIC) PUSH BUTTON AUDIO BT120-PBA-01 SOUND TRANSIT BAY 1 1-1" CONDUIT BT120-SC-109 LIGHT POLE 12 1-1" CONDUIT BT120-SC-114 1-1" CONDUIT BT120-SC-113 1-2" CONDUIT BT120-SC-115 1-1" CONDUIT BT120-SC-111 1-2" CONDUIT BT120-SC-112 JUNCTION BOX BT120-HH-200 1-1.5" CONDUIT BT120-SC-160 1-1" CONDUIT BT120-SC-163 1-1" CONDUIT BT120-SC-162 JUNCTION BOX BT120-HH-201 1-1" CONDUIT BT120-SC-161 CANOPY COLUMN STUB UP BT120-CC-03 BT120-CAM-104 CANOPY-MOUNTED BT120-CAM-103 CANOPY-MOUNTED JUNCTION BOX BT120-HH-202 1-1" CONDUIT BT120-SC-164 1-1" CONDUIT BT120-SC-166 JUNCTION BOX BT120-HH-203 1-1" CONDUIT BT120-SC-165 LAYER 2 POE SWITCH 1-2" CONDUIT BT120-SC-221 1-2" CONDUIT BT120-SC-220 DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 3 6 P M BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JFS204 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS SOUND TRANSIT BAY 1 RISER DIAGRAMJM JD PPL ISSUED FOR BID12/10/2024 12/02/2024 0604 RTA/CN 0205-24 LEGEND: CAT6 CAT6 POE FIBER SPARE PLATFORM COMMUNICATIONS CABINET BT120-DC-02 TYPE 2 JUNCTION BOX BT120-HH-106 1-3" CONDUIT BT120-SC-126 TO BT120-HH-110 TO ST NETWORK RACK TELECOMM ROOM BT120L1208 TO BT120-HH-07 TYPE 2 JUNCTION BOX BT120-HH-107 2-2" CONDUIT BT120-SC-28, BT120-SC-29 1-2" CONDUIT BT120-SC-127 1-2" CONDUIT BT120-SC-125 CANOPY COLUMN STUB UP BT120-CC-06 BT120-CAM-108 CANOPY-MOUNTED BT120-CAM-107 CANOPY-MOUNTED CANOPY VMS BT120-VMS-07 (NIC) EPC CANOPY VMS BT120-VMS-08 (NIC) EPC 1-2" CONDUIT BT120-SC-131 TVM BT120-TVM-02 (NIC) NGORCA VALIDATOR BT102-SCR-04 (NIC) TYPE 2 JUNCTION BOX BT120-HH-105 1-2" CONDUIT BT120-SC-132 CANOPY COLUMN STUB UP BT120-CC-05 BT120-CAM-105 CANOPY-MOUNTED BT120-CAM-106 CANOPY-MOUNTED PYLON VMS BT120-VMS-04 (NIC) EPC NGORCA VALIDATOR BT102-SCR-03 (NIC) PUSH BUTTON AUDIO BT120-PBA-02 1-2" CONDUIT BT120-SC-133 SOUND TRANSIT BAY 8 1-1" CONDUIT BT120-SC-129 1-1" CONDUIT BT120-SC-130 1-1" CONDUIT BT120-SC-135 1-1" CONDUIT BT120-SC-136 1-2" CONDUIT BT120-SC-134 JUNCTION BOX BT120-HH-204 1-1" CONDUIT BT120-SC-170 1-1" CONDUIT BT120-SC-171 1-1" CONDUIT BT120-SC-172 JUNCTION BOX BT120-HH-207 1-1" CONDUIT BT120-SC-1741-1" CONDUIT BT120-SC-175 1-1" CONDUIT BT120-SC-177 1-1" CONDUIT BT120-SC-176 JUNCTION BOX BT120-HH-208 JUNCTION BOX BT120-HH-205 LAYER 2 POE SWITCH 1-2" CONDUIT BT120-SC-222 1-2" CONDUIT BT120-SC-223 DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 3 6 P M BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JFS205 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS SOUND TRANSIT BAY 8 RISER DIAGRAMJM JD PPL ISSUED FOR BID12/10/2024 12/02/2024 0605 RTA/CN 0205-24 PLATFORM COMMUNICATIONS CABINET BT120-DC-05 TO BT120-HH-106 TYPE 2 JUNCTION BOX BT120-HH-110 1-2" CONDUIT BT120-SC-145 CANOPY COLUMN BT120-CC-12 BT120-CAM-112 CANOPY-MOUNTED BT120-CAM-111 CANOPY-MOUNTED 1-2" CONDUIT BT120-SC-144 LIGHT POLE 24 BT120-CAM-114 POLE-MOUNTED BT120-CAM-113 POLE-MOUNTED LIGHT POLE 25 BT120-CAM-116 POLE-MOUNTED BT120-CAM-115 POLE-MOUNTED 1-2" CONDUIT BT120-SC-146 1-2" CONDUIT BT120-SC-147 TYPE 2 JUNCTION BOX BT120-HH-113 TO BT120-HH-11 2-2" CONDUIT BT120-SC-36, BT120-SC-37 CANOPY COLUMN BT120-CC-15 BT120-CAM-109 CANOPY-MOUNTED BT120-CAM-110 CANOPY-MOUNTED 1-2" CONDUIT BT120-SC-148 SOUND TRANSIT BAY BAYS 3, 4, 5, & 6 LEGEND: CAT6 CAT6 POE FIBER 2-2" CONDUIT BT120-SC-152 BT120-SC-153 1-2" CONDUIT BT120-SC-127 CUSTOMER EMERGENCY STATION BT120-CES-01 1-1" CONDUIT BT120-SC-142 1-2" CONDUIT BT120-SC-157 JUNCTION BOX BT120-HH-220 JUNCTION BOX BT120-HH-218 1-1" CONDUIT BT120-SC-183 JUNCTION BOX BT120-HH-219 1-1" CONDUIT BT120-SC-184 1-1" CONDUIT BT120-SC-186 1-1" CONDUIT BT120-SC-185JUNCTION BOX BT120-HH-213 JUNCTION BOX BT120-HH-214 1-1" CONDUIT BT120-SC-189 1-1" CONDUIT BT120-SC-190 1-1" CONDUIT BT120-SC-192 JUNCTION BOX BT120-HH-215 1-1" CONDUIT BT120-SC-191 LAYER 2 POE SWITCH DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 3 7 P M BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JFS206 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS SOUND TRANSIT OTHER BAYS RISER DIAGRAMJM JD PPL ISSUED FOR BID12/10/2024 12/02/2024 0606 RTA/CN 0205-24 KCM BAY 2 AND 7 PLATFORM COMMUNICATIONS CABINET BT120-DC-03 TYPE 2 JUNCTION BOX BT120-HH-108 1-2" CONDUIT BT120-SC-120 TO KCM NETWORK RACK TELECOMM ROOM BT120L1208 BT120-HH-08 CANOPY COLUMN STUB UP BT120-CC-06 CANOPY VMS BT120-VMS-06 EPC CANOPY VMS BT120-VMS-05 EPC PUSH BUTTON AUDIO BT120-PBA-03 (FUTURE) 1-2" CONDUIT BT120-SC-123 TYPE 2 JUNCTION BOX BT120-HH-109 PUSH BUTTON AUDIO BT120-PBA-04 (FUTURE) 1-2" CONDUIT BT120-SC-121 TO BT120-HH-121 SEE SHEET BT120-JFS208 1-2" CONDUIT BT120-SC-138 2-2" CONDUIT BT120-SC-30, BT120-SC-31 CANOPY COLUMN STUB UP BT120-CC-08 CANOPY VMS BT120-VMS-09 EPC CANOPY VMS BT120-VMS-10 EPC 1-2" CONDUIT BT120-SC-137 KCM BAY 7 1-1" CONDUIT BT120-SC-122 1-1" CONDUIT BT120-SC-204 1-1" CONDUIT BT120-SC-173 1-1" CONDUIT BT120-SC-155 LEGEND: CAT6 CAT6 POE FIBER SPARE CONDUIT JUNCTION BOX BT120-HH-206 JUNCTION BOX BT120-HH-216 JUNCTION BOX BT120-HH-217 1-1" CONDUIT BT120-SC-193 1-1" CONDUIT BT120-SC-194 TYPE 2 JUNCTION BOX BT120-HH-120 1-2" CONDUIT BT120-SC-200 1-2" CONDUIT BT120-SC-201 LAYER 2 SWITCH DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 3 7 P M BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JFS207 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS KCM BAY 2 AND 7 RISER DIAGRAMJM JD PPL ISSUED FOR BID12/10/2024 12/02/2024 0607 RTA/CN 0205-24 LAYER 2 SWITCH TYPE 2 JUNCTION BOX BT120-HH-111 1-2" CONDUIT BT120-SC-141 TO BT120-HH-109 SEE SHEET BT120-JFS207 1-2" CONDUIT BT120-SC-138 CANOPY COLUMN STUB UP BT120-CC-15 CANOPY VMS BT120-VMS-14 EPC CANOPY VMS BT120-VMS-13 EPC PUSH BUTTON AUDIO BT120-PBA-06 (FUTURE) TYPE 2 JUNCTION BOX BT120-HH-114 1-2" CONDUIT BT120-SC-143PUSH BUTTON AUDIO BT120-PBA-08 (FUTURE) TYPE 2 JUNCTION BOX BT120-HH-112 1-2" CONDUIT BT120-SC-149 CANOPY COLUMN STUB UP BT120-CC-14 CANOPY VMS BT120-VMS-11 EPC CANOPY VMS BT120-VMS-12 EPC CANOPY VMS BT120-VMS-15 EPC CANOPY VMS BT120-VMS-16 EPC 1-2" CONDUIT BT120-SC-150 PUSH BUTTON AUDIO BT120-PBA-05 (FUTURE) KCM BAYS 3, 4, 5, & 6 1-1" CONDUIT BT120-SC-140 1-1" CONDUIT BT120-SC-151 1-2" CONDUIT BT120-SC-139 ALL LINES SHOWN REPRESENT CABLING INSIDE 1-1" CONDUIT UNLESS OTHERWISE NOTED. NOTE: 1-2" CONDUIT BT120-SC-156 LEGEND: CAT6 CAT6 POE FIBER SPARE CONDUIT JUNCTION BOX BT120-HH-211 JUNCTION BOX BT120-HH-212 1-1" CONDUIT BT120-SC-187 1-1" CONDUIT BT120-SC-188 JUNCTION BOX BT120-HH-210 1-1.5" CONDUIT BT120-SC-180 1-1" CONDUIT BT120-SC-181 JUNCTION BOX BT120-HH-209 1-1" CONDUIT BT120-SC-182 TYPE 2 JUNCTION BOX BT120-HH-115 1-2" CONDUIT BT120-SC-196 1-1" CONDUIT BT120-SC-195 TYPE 2 JUNCTION BOX BT120-HH-121TO BT120-HH-109 SEE SHEET BT120-JFS207 1-2" CONDUIT BT120-SC-202 1-2" CONDUIT BT120-SC-203 PLATFORM COMMUNICATIONS CABINET BT120-DC-04 DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 3 7 P M BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JFS208 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS KCM OTHER BAYS RISER DIAGRAMJM JD PPL ISSUED FOR BID12/10/2024 12/02/2024 0608 RTA/CN 0205-24 PBA INSTALLED BY OTHERS (NIC) TOP OF PLATFORM STUB CONDUIT UP TO PBA PBA POLE INSTALLED BY OTHERS (NIC) INSTALL CONDUIT SLEEVE AND CAP LEVEL WITH PLATFORM DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 2 7 P M 1" = 1'-0" BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCD204 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS COMMUNICATIONS DETAILSJMJDPPL ISSUED FOR BID12/10/2024 SCALE: NTS STRIDE PBA COLUMN DETAIL A - 12/02/2024 0609 RTA/CN 0205-24 VMS BRACKET (NIC) 2 VMS DISPLAYS (NIC) PENETRATE SOFFIT, COORDINATE INSTALLATION WITH LIGHTING INSTALL COMMUNICATIONS CABLE INSIDE MOUNTING PIPE SEE ELECTRICAL PLAN BT120-EPP211 TO BT120-EPP215 FOR POWER CABLE INSTALL CONDUIT INSIDE SHELTER CANOPY COIL CABLE AND SECURE TO POSTS VMS BRACKET ENCLOSURE. KCM PROCURED, CONTRACTOR INSTALLED. INSTALL CONDUIT INSIDE SHELTER CANOPY PENETRATE SOFFIT, COORDINATE INSTALLATION WITH LIGHTING FIXTURES SEE ELECTRICAL PLAN EPP211 TO EPP215 FOR POWER CABLE INSTALL COMMUNICATIONS CABLE INSIDE MOUNTING PIPE 2 VMS DISPLAYS (NIC) SHELTER ROOF TERMINATE POWER CABLES ON A PLUG INSIDE THE NEMA BOX WITHIN THE VMS BRACKET ENCLOSURE AND COIL THE COMMUNICATION CABLE INSIDE THE ENCLOSURE. INSTALL CCTV CAMERA. RECESS CAMERA SUCH THAT ONLY THE LENS HOUSING IS VISIBLE. INSTALL RECESSED CEILING MOUNT FLUSH TO SOFFIT. SEE ARCHITECTURAL DWG BT120-ACP211 TO BT120-ACTP214 FOR SOFFIT PANEL DETALS CONNECT SYSTEMS CONDUIT INTO RECESSED MOUNT TOP OF CANOPY SOFFIT DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION AS NOTED 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 2 7 P M BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCD205 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS COMMUNICATIONS DETAILSJM JD PPL ISSUED FOR BID12/10/2024 SCALE: NTS SOUND TRANSIT CANOPY VMS DETAIL 1 - SCALE: NTS KCM RTIS DETAIL 3 - SCALE: NTS SHELTER CCTV - DETAIL 2 - 1. THE TERMS RTIS AND VMS ARE USED INTERCHANGEABLY. RTIS REFERS TO THE KCM CANOPY REAL TIME DISPLAY SYSTEM, VMS IS USED FOR ST REAL TIME DISPLAY SYSTEMS. 2. SEE DWG BT120-SGD113 FOR VMS AND RTIS MOUNTING DETAILS GENERAL NOTES: 12/02/2024 0610 RTA/CN 0205-24 TVM CABINET (NIC) FOUNDATION SEE STRUCTURAL BT120-SFP212 TOP OF PLATFORM CAP AND PULL CORD INSTALL CONDUIT SLEEVE AND CAP LEVEL WITH PLATFORM PYLON (NIC) FUTURE CURB VMS DISPLAY (NIC) STUB CONDUIT FLUSH WITH FUTURE CURB HEIGHT TOP OF PLATFORM INSTALL CONDUIT SLEEVE AND CAP LEVEL WITH PLATFORM SCR AND POLE (NIC) TOP OF PLATFORM STUB UP CONDUIT INSTALL CONDUIT SLEEVE AND CAP LEVEL WITH PLATFORM DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 2 7 P M 1" = 1'-0" BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCD206 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS COMMUNICATIONS DETAILSJM JD PPL ISSUED FOR BID12/10/2024 SCALE: NTS TVM DETAIL FRONT VIEW 1 -SCALE: NTS PYLON VMS DETAIL 2 -SCALE: NTS SMART CARD READER (SCR) DETAIL 3 - 12/02/2024 0611 RTA/CN 0205-24 STATION PLATFORM CONDUIT PROTECTION W/ BUSHING (TYP) CAP FOR FUTURE CABINET AND INSTALL PULL CORDS COMMUNICATION CABINET FRONT FACE SE E B T 1 2 0 -SG Y 4 0 3 FO R F O U N D A T I O N CONDUIT TO DEVICES 6" CONDUIT WITH PULL CORD. (TYP) FASTEN DECORATIVE LID AND FRAME AND USE WOOD BLOCKING TO SUPPORT AND LEVEL THE DECORATIVE LID AND FRAME PRIOR TO CONCRETE POUR. DECORATIVE LID SHALL BE LEVEL AND FLUSH WITH PLATFORM. DECORATIVE LID FRAME INSET INTO CONCRETE PLATFORM TOP OF PLATFORM CONCRETE TOP OF LID FILL DECORATIVE LID WITH CONCRETE TO MATCH PLATFORM TOP OF JUNCTION BOX LID DECORATIVE LID FLANGE INSET INTO CONCRETE PLATFORM WSDOT TYPE 2 JUNCTION BOX WSDOT TYPE 2 JUNCTION BOX CRUSHED SURFACING TYPE 2 WSDOT JUNCTION BOX WITH DECORATIVE LID TYPE 2 WSDOT JUNCTION BOX SEE CENTER POINT LOCATED ON PLAN SHEETS INSIDE WALL OF JUNCTION BOX DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 2 8 P M BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCD207 12/10/2024R.PARGAS J. ALTCHECH SYSTEMS COMMUNICATIONS DETAILSJM JD PPL ISSUED FOR BID12/10/2024 SCALE: NTS COMMUNICATIONS CABINET FOUNDATION ELEVATION 1 -SCALE: NTS COMMUNICATIONS JUNCTION BOX - CONDUIT ENTRY DETAIL 2 - 1. ALL CONDUITS SHALL HAVE A COUPLING FLUSH WITH THE SURFACE OF THE FOUNDATION AND A NIPPLE THAT EXTENDS 2" UP 2. INSTALL CONDUITS PER WIRE NOTES, SEE PLANS 3. CABINET DOOR SHALL BE ORIENTED AS SHOWN ON THE PLANS. NOTES: 12/02/2024 0612 RTA/CN 0205-24 FIBER TERMINATION PANEL POE SWITCH WITH EXPANSION AND POWER SUPPLY ON RACK MOUNTED RAIL. PROCURED BY ST FOR CONTRACTORS TO INSTALL CABLE MANAGEMENT MODULAR CAT6 SURGE PROTECTION DRAWER POWER DISTRIBUTION ASSEMBLY STRIP HEATER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 PIMS STATION CONTROL UNIT (NIC) 2' - 6 " 2' - 1" 2' - 5" 2' - 1 0 " 2" O F F S E T - CA B I N E T / FO U N D A T I O N S P A C I N G 1" F O U N D A T I O N CH A M F E R 3' - 5" PLATFORM COMMUNICATION CONDUIT (CAT6) ELECTRICAL CONDUIT FROM ELECTRICAL CABINET NETWORK COMMUNICATION CONDUIT (FIBER OPTIC) CABINET FOUNDATION PEDESTAL TO BE 6" HEIGHT. GROUND VARIES PER CABINET LOCATION. SEE PLANS COMMUNICATION CABINET CENTER CABINET ON PEDESTAL PLAN VIEW DOOR 6" DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 3 : 1 0 : 0 7 P M BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCD208 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS ST COMMUNICATIONS CABINETJMJDPPL ISSUED FOR BID12/10/2024 SCALE: NTS ST COMMUNICATION CABINET ELEVATION DETAIL 2 -SCALE: NTS ST COMMUNICATIONS CABINET FOUNDATION DETAIL 1 - NOTE : CONDUITS SHOWN FOR REFERENCE ONLY. SEE PLAN SHEETS FOR QUANTITY AND SIZE OF CONDUIT STUB UPS TO EACH CABINET. 1. THE ST COMMUNICATIONS CABINET IS POWERED FROM UNINTERRUPTIBLE POWER SUPPLY INSIDE THE CORE FACILITY. SEE DWG B120-EPS102 FOR DETAILS. GENERAL NOTES: 12/02/2024 0613 RTA/CN 0205-24 FIBER TERMINATION PANEL SWITCH WITH EXPANSION AND POWER SUPPLY ON RACK MOUNTED RAIL. PROCURED BY KCM FOR CONTRACTORS TO INSTALL CABLE MANAGEMENT MODULAR CAT6 SURGE PROTECTION DRAWER POWER DISTRIBUTION ASSEMBLY STRIP HEATER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 UPS BATTERY BACKUP UPS 2' - 6 " 2' - 1" 2' - 5" 2' - 1 0 " 2" O F F S E T - CA B I N E T / FO U N D A T I O N S P A C I N G 1" F O U N D A T I O N CH A M F E R 3' - 5" PLATFORM COMMUNICATION CONDUIT (CAT6) ELECTRICAL CONDUIT FROM ELECTRICAL CABINET NETWORK COMMUNICATION CONDUIT (FIBER OPTIC) CABINET FOUNDATION PEDESTAL TO BE 6" HEIGHT. GROUND VARIES PER CABINET LOCATION. SEE PLANS COMMUNICATION CABINET CENTER CABINET ON PEDESTAL PLAN VIEW DOOR DOOR 9" DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 2 8 P M BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCD209 12/10/2024R.PARGAS J.ALTCHECH SYSTEMS KCM COMMUNICATIONS CABINETJM JD PPL ISSUED FOR BID12/10/2024 SCALE: NTS KCM COMMUNICATION CABINET ELEVATION DETAIL 2 - SCALE: NTS KCM COMMUNICATIONS CABINET FOUNDATION DETAIL 1 - NOTE : CONDUITS SHOWN FOR REFERENCE ONLY. SEE PLAN SHEETS FOR QUANTITY AND SIZE OF CONDUIT STUB UPS TO EACH CABINET. 12/02/2024 0614 RTA/CN 0205-24 DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 2 8 P M BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCD210 12/10/2024R. PARGAS J. ALTCHECH SYSTEMS CONDUIT PENETRATION DETAILJM JD PPL ISSUED FOR BID12/10/2024 SCALE: NTS CONDUIT PENETRATION DETAIL 1 - ATTACH CONDUIT TO METAL GIRTS WITHIN BEAMS WITH ROUTING CLAMP 3" x 2.5" CUTOUT IN BEAM. SEE DWG BT120-SGP312 FOR DETAILS. BOLT CLAMP TO METAL GIRT CENTER CONDUIT THROUGH PENETRATION SCALE: NTS - CANOPY JUNCTION BOX DETAIL 2 SCREW 5X5 CONDUIT JUNCTION BOX DIRECTLY INTO STRUCTURAL BEAM WITH SELF-TAPPING SCREWS BEFORE CONDUIT INSTALLATION STRUCTURAL BEAM 1" CANOPY CONDUIT JUNCTION BOX 1" CANOPY CONDUIT CONDUIT PENETRATION THROUGH BEAM, SEE DETAIL 1 AND DWG BT120-SGP312 FOR DETAILS. NOTE: THE NUMBER OF CONDUITS AND THEIR LOCATION RELATIVE TO THE BEAM VARYS BY LOCATION. SEE DWG BT120-JCP206 TO BT120-JCP209 12/02/2024 0615 RTA/CN 0205-24 CCTV CAMERA INSTALLATION SCHEDULE EQUIPMENT ID LIGHT POLE (IF APPLICABLE) CAMERA NAME TARGET AREA CAMERA TYPE FOV 1 FOCAL LENGTH FOV 2 FOCAL LENGTH FOV 3 FOCAL LENGTH FOV 4 FOCAL LENGTH FOV 1 ORBI T (°) FOV 2 ORBI T (°) FOV 3 ORBIT (°) FOV 4 ORBIT (°) FOV 1 TILT (°) FOV 2 TILT (°) FOV 3 TILT (°) FOV 4 TILT (°) BT120-CAM-01 NORTH EAST WALKWAY FENCE SENSOR 1 ON CORRIDOR MODE FACING EAST, SENSOR 4 ON CORRIDOR FACING WEST. OTHER 2 FACING PLATFORM AND WALKWAYS 360 MULTISENSOR 6.00 4.00 3.18 7.00 75 60 10 285 25 25 25 25 BT120-CAM-02 35 PARKING LOT PARKING LOT; ESPECIALLY DRIVEWAY ENTRANCE 360 MULTISENSOR 3.18 4.00 4.00 4.00 0 90 180 270 25 25 25 25 BT120-CAM-03 11 N OF PARKING LOT LIGHT POLE DRIVEWAY AND SIDEWALK. VIEWS OF LAYOVER BAY 360 MULTISENSOR 3.18 4.00 4.00 4.00 0 90 180 270 25 25 25 25 BT120-CAM-04 50 PARKING LOT PARKING LOT 360 MULTISENSOR 3.18 3.18 3.18 3.18 0 90 180 270 25 25 25 25 BT120-CAM-05 13 N OF PARKING LOT LIGHT POLE -2 PARKING LOT AND CROSSWALKS 360 MULTISENSOR 4.00 4.00 4.00 4.00 0 90 180 270 25 25 25 25 BT120-CAM-06 NORTH EAST WALKWAY FENCE SENSOR 1 ON CORRIDOR MODE FACING EAST, SENSOR 4 ON CORRIDOR FACING WEST. OTHER 2 FACING PLATFORM AND WALKWAYS 360 MULTISENSOR 7.00 4.00 3.18 7.00 80 30 320 285 25 25 25 25 BT120-CAM-07 20 BAY 5 AREA LIGHT POLE ROAD AROUND BAY 5; CROSSWALK 360 MULTISENSOR 3.18 4.00 4.00 4.00 0 90 180 270 25 25 25 25 BT120-CAM-08 31 WEST SIDE BIKE LOCKERS BIKE LOCKER, VIEW OF PATHWAY DOWN TO PARKING LOT DRIVEWAY 360 MULTISENSOR 3.18 7.40 3.18 3.18 0 60 180 270 30 22 25 25 BT120-CAM-09 32 PARKING LOT CES LIGHT POLE CES AND PARKING LOT 360 MULTISENSOR 3.18 3.18 3.18 3.18 0 90 180 270 30 25 25 25 BT120-CAM-10 26 KCM CHARGING BAY E ENTIRE CHARGING BAY 360 MULTISENSOR 3.18 3.18 3.18 3.18 0 90 180 270 25 25 25 25 BT120-CAM-11 CHARGING ELECTRICAL BUILDING ENTIRE ROOM, ESP. ENTRANCE. SENSOR 1 TILTED TO COVER BLIND SPOT & ENTERANCE. SENSORS 2, 3, AND 4 ON CORRIDOR MODE TO COVER ENTIRE ROOM. 360 MULTISENSOR 7.40 6.00 3.90 7.00 0 30 45 345 40 25 25 25 BT120-CAM-12 78 SOUTHERN DRIVEWAYS SOUTHERN DRIVEWAYS AND ENTRANCE TO CHARGING CABINETS 360 MULTISENSOR 3.18 3.18 3.18 3.18 0 90 180 270 25 25 25 25 BT120-CAM-13 75 SOUTH WESTERN PATH -2 PED PATH -SENSOR 1 TILTED TO COVER BLIND SPOT 360 MULTISENSOR 4.00 4.00 4.00 5.00 0 60 120 270 30 22 25 25 BT120-CAM-14 74 SOUTH WESTERN PATH PED PATH -SENSOR 1 TILTED TO COVER BLIND SPOT 360 MULTISENSOR 4.00 4.00 4.00 5.00 0 60 120 270 30 22 25 25 BT120-CAM-15 55 SOUTHERN PARKING LOT VIEW OF PATHWAY DOWN TO PARKING LOT DRIVEWAY 360 MULTISENSOR 4.00 4.00 4.00 4.00 0 30 80 270 30 25 25 25 BT120-CAM-16 73 EASTERN ENTRANCE EASTERN ENTRACE AND PATHWAY. SENSORS 2 AND 4 ON CORRIDOR MODE FOR PATH AND CROSSWALK. 360 MULTISENSOR 3.18 60.00 3.18 6.00 0 90 80 290 25 25 25 25 BT120-CAM-17 76 SOUTHERN PATHWAYS SOUTHERN PATHWAYS 360 MULTISENSOR 3.18 3.18 3.18 3.18 0 90 180 270 25 25 25 25 BT120-CAM-18 79 SOUTHERN PATHWAYS -2 SOUTHERN PATHWAYS 360 MULTISENSOR 3.18 3.18 3.18 3.18 0 90 180 270 25 25 25 25 BT120-CAM-19 KCM CHARGING BAY W COVERS W ENTRNACE TO CHARGING BAY. SENSOR 2 COVERS ROOM, SENSOR 1 N EQUIPMENT & YARD. SENSORS 3 AND 4 TILTED FOR W DOOR AREA.360 MULTISENSOR 3.18 3.18 3.18 3.18 10 100 250 315 25 35 35 40 BT120-CAM-100 10 BAY 1 LIGHT POLE BAY 1 & LAYOVER PLATFORM 360 MULTISENSOR 3.18 3.18 3.18 3.18 0 90 180 270 25 25 25 25 BT120-CAM-101 BAY 1 CANOPY -1 BAY 1 PLATFORM. SENSOR 1 TILTED FOR BLIND SPOT.360 MULTISENSOR 4.00 5.00 4.00 4.00 0 90 180 270 50 25 25 25 BT120-CAM-102 BAY 1 CANOPY -2 TVM LEVEL AND PLATFORM. SENSOR 1 TILTED FOR TVM.360 MULTISENSOR 3.18 4.00 4.00 4.00 0 90 180 270 45 25 25 25 BT120-CAM-103 LAYOVER BAY CANOPY -1 LAYOVER PLATFORM. SENSOR 1 TILTED FOR BLIND SPOT AND VALIDATOR. 360 MULTISENSOR 4.00 4.00 4.00 4.00 0 90 180 270 45 25 25 25 BT120-CAM-104 LAYOVER BAY CANOPY -2 PLATFORM INCLD PED ENTRANCE. SENSOR 1 TILTED FOR BLIND SPOT. 360 MULTISENSOR 3.18 4.00 4.00 4.00 0 90 180 270 45 25 25 25 BT120-CAM-105 BAY 2 CANOPY -2 BAY 2 PLATFORM INCLD AREA BTWN CANOPIES. SENSOR 1 TILTED FOR SHELTER AND PYLON.360 MULTISENSOR 3.18 4.00 4.00 4.00 0 90 180 270 45 25 25 25 BT120-CAM-106 BAY 2 CANOPY -1 BAY 2 PLATFORM. SENSOR 1 TILTED FOR SHELTER. 360 MULTISENSOR 3.18 4.00 4.00 4.00 0 90 180 270 45 25 25 25 BT120-CAM-107 BAY 8 CANOPY -2 BAY 8 AND TVM. SENSOR 1 TILTED FOR TVM. 360 MULTISENSOR 3.18 4.00 4.00 4.00 0 90 180 270 45 25 25 25 BT120-CAM-108 BAY 8 CANOPY -1 PLATFORM INCLD PED ENTRANCE. SENSOR 1 TILTED FOR BLIND SPOT & SHELTER. 360 MULTISENSOR 3.18 4.00 4.00 4.00 0 90 180 270 45 25 25 25 BT120-CAM-109 BAY 3 CANOPY -1 PLATFORM INCLD PED ENTRANCE. SENSOR 1 TILTED FOR BLIND SPOT. 360 MULTISENSOR 3.18 4.00 6.00 4.00 0 90 180 270 55 25 25 25 BT120-CAM-110 BAY 4 CANOPY BAY 4 PLATFORM. SENSOR 4 IN CORRIDOR MODE FACING BAY 5. SENSOR 3 TILTED FOR BLIND SPOT 360 MULTISENSOR 3.18 3.18 3.18 6.00 0 90 180 280 25 25 25 25 BT120-CAM-111 BAY 7 CANOPY -1 PLATFORM INCLD PED ENTRANCE. SENSOR 1 TILTED FOR BLIND SPOT. 360 MULTISENSOR 3.18 3.18 3.18 3.18 0 90 180 270 45 25 40 25 BT120-CAM-112 BAY 6 CANOPY BAY 6 AND 5 PLATFORM. SENSOR 4 IN CORRIDOR MODE FACING BAY 5 360 MULTISENSOR 4.00 4.00 4.00 6.00 0 90 180 290 25 25 25 25 BT120-CAM-113 24 BAY 4 LIGHT POLE -WEST SIDE BAY 4 AND 6 PLATFORM -SENSORS 1 AND 2 FACING WEST CORRIDOR MODE. OTHER 2 SENSORS FACING CES AT ID LEVEL 360 MULTISENSOR 7.00 7.00 3.18 3.18 0 15 80 280 25 25 25 25 BT120-CAM-114 24 BAY 4 LIGHT POLE -EAST SIDE SENSOR 1 COVERS BIKE LOCKERS AT ID LEVEL. OTHER 3 SENSORS COVER BAY 4 PLATFORM AND SHELTER 360 MULTISENSOR 6.00 4.00 4.00 4.00 0 90 180 270 25 25 25 25 BT120-CAM-115 25 BAY 5 LIGHT POLE -WEST SIDE BIKE LOCKERS AND AREA BETWEEN BAYS 4 AND 5 360 MULTISENSOR 7.00 4.00 4.00 4.00 0 80 180 280 25 25 25 25 BT120-CAM-116 25 BAY 5 LIGHT POLE -EAST SIDE EAST END OF PLATFORM AND DRIVEWAYS 360 MULTISENSOR 6.00 3.18 3.18 3.18 0 90 180 270 25 25 25 25 DRAWING NO.: FACILITY ID: SHEET No:REV: SCALE: FILENAME: CONTRACT No.: SUBMITTAL DATE:DATE: LI N E I S 1 " A T FU L L S C A L E REVIEWED BY:DATE:SUBMITTED BY: DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: No.DATE DSN CHK APP REVISION NTS 0 BI M 3 6 0 : / / U S W A _ D 3 4 5 8 6 0 0 _ B U S _ R A P I D _ T R A N S I T _ G E C / S 1 - B T 1 2 0 - J - C A N - v 2 0 2 0 . r v t 11 / 1 5 / 2 0 2 4 1 : 0 8 : 2 9 P M BT120 S1-BT120-J-CAN-v2020 12/10/2024 12/10/2024 J.MARGOLIS W.TURNER J.DONG P.LAVALLEE STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 BT120-JCD211 12/10/2024R.PARGAS J.ALTCHECH SYSTEMS CCTV CAMERA DATAJM JD PPL ISSUED FOR BID12/10/2024 SCALE: NTS CAMERA ORBIT DETAIL 1 - 0° 90° 180° 270° 45° 135°225° 315° CAMERA SENSOR(S) ORBIT IN TRACK SCALE: NTS CAMERA TILT DETAIL 2 0° 5° 65° CAMERA SENSOR ROOF OR TOP OF MOUNT CAMERA DOME 0 DEGREE ARROW SYMBOLS SEEN ON PLAN VIEWS SENSOR 1 SENSOR 2 SENSOR 3 SENSOR 4 MINIMUM TILT MAXIMUM TILT 1. REFER TO SPECIFICATION SECTION 28 20 00: VIDEO SUVEILLANCE GENERAL NOTES: 12/02/2024 0616 RTA/CN 0205-24 DEVICE PORT LABELING02-MDF-R04-P2-2,3 PORT NUMBER(S) PATCH PANEL NUMBER RACK NUMBER MDF ROOM FLOOR NUMBER LABELING SCHEME CABLING NOTES FOR IP-BASED DEVICES WITHIN 295' CABLE LENGTH: PROVIDE OUTDOOR RATED CATEGORY 6A ETHERNET CABLE PROVIDE BUILDING ENTRANCE PROTECTOR TERMINAL(S). FOR IP-BASED DEVICES OUTSIDE 295" CABLE LENGTH: PROVIDE MINIMUM 6-STRAND MULTIMODE FIBER WITH MEDIA CONVERTER TO NEAREST TELECOM ROOM. INSTALL MEDIA CONVERTER IN A NEMA 4 BOX. PROVIDE POWER TO FEED MEDIA CONVERTERS AS NEEDED. COORDINATE WITH ELECTRICAL. INFRASTRUCTURE REQUIREMENTS 1. PROVIDE AND INSTALL DOUBLE-GANG BACK BOX WITH SINGLE- GANG PLASTER RING AND CONDUIT STUB-UP WITH PULLSTRING FROM EACH DEVICE LOCATION TO NEAREST TECHNOLOGY PATHWAY IN ACCESSIBLE CEILING. SIZE CONDUITS NOT TO EXCEED FILL RATIO TABLES ON SHEET JCN001. MINIMUM SIZES AS FOLLOWS: 1.1. 1" FOR TELECOMMUNICATIONS 1.2. 1" FOR SECURITY 2. PROVIDE AND INSTALL PATHWAYS AS FOLLOWS: 2.1. CABLE TRAYS ABOVE ACCESSIBLE CEILINGS 2.2. J-HOOKS (ONLY FOR SMALL NUMBER OF CABLES) ABOVE ACCESSIBLE CEILINGS. 2.3. CONDUITS / SLEEVES ABOVE INACCESSIBLE CEILINGS AND THROUGH WALLS, UON. 3. FIRESTOP WALL/FLOOR PENETRATIONS. 4. PROVIDE PULLSTRING TO ALL CONDUITS AND SLEEVES. 5. PROVIDE PLASTIC BUSHINGS ON ALL CONDUIT ENDS. GENERAL SYMBOLS XXXX ROOM TAGROOM 6" WIDE VERTICAL WIRE MANAGER 2-POST EQUIPMENT RACK WALL MOUNTED EQUIPMENT RACK TELECOM GROUNDING BUSBAR TELECOM ROOM EQUIPMENT SYMBOLS SYSTEM PANEL: HEAD END EQUIPMENT FIRE RESISTANT 3/4" PLYWOOD BACKBOARD 110 BLOCK WITH LEGS 10" WIDE VERTICAL WIRE MANAGER CHAIN LINK FENCE FLOOR OR SURFACE MOUNTED 208V/120V PANELBOARD A. TELECOMMUNICATION GENERAL NOTES: 1. ALL STRUCTURED CABLING SYSTEM (SCS) & LOW VOLTAGE (LV) CABLING USED THROUGHOUT THIS PROJECT MUST COMPLY WITH THE REQUIREMENTS AS OUTLINED IN THE STANDARDS, CODES AND LOCAL REGULATIONS FOR THE FOLLOWING: ANSI/TIA-568.0-E, 568.1-E, 568.2-E, 568.3-E, 568.4-E, 568.5, ANSI/TIA-569-E, ANSI/TIA-606-E, ANSI/TIA-607-E, ANSI/TIA-758-B, BICSI TDMM (CURRENT VERSION), NEC ARTICLE 90, ARTICLE 300, NEC ARTICLE 645, NEC ARTICLE 646, NEC ARTICLE 725, NEC ARTICLE 760, NEC ARTICLE 770, NEC ARTICLE 800, NEC ARTICLE 830. THE SCS & TELECOMMUNICATION SYSTEM(S) CABLING MUST MEET ALL LOCAL AND OTHER PREVAILING CODES. 2. ALL SCS & LV CABLING MUST BEAR UL LISTED TYPE CMP (PLENUM RATED). ALL FIBER OPTIC CABLING MUST BEAR OFNP (PLENUM RATED) AND/OR OFNR (RISER RATED) AND/OR OFN/G (GENERAL PURPOSE). THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING APPROPRIATELY RATED CABLE FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED. 3. ALL INSTALLATION MUST BE DONE IN CONFORMANCE WITH ANSI/TIA-568, STANDARDS AND MANUFACTURER'S INSTALLATION GUIDELINES. THE CONTRACTOR MUST ENSURE THAT THE CABLE'S MINIMUM BEND RADIUS AND MAXIMUM PULLING TENSIONS OF THE SPECIFIED DISTRIBUTION CABLES ARE NOT EXCEEDED. THE CABLE BENDS MUST MAINTAIN THE PROPER RADIUS DURING THE PLACEMENT OF THE CABLING. FAILURE TO FOLLOW THE APPROPRIATE GUIDELINES WILL REQUIRE THE CONTRACTOR TO PROVIDE, IN A TIMELY FASHION, ANY ADDITIONAL MATERIAL AND LABOR NECESSARY TO PROPERLY RECTIFY THE SITUATION TO THE SATISFACTION AND WRITTEN APPROVAL OF THE OWNERS REPRESENTATIVE. THIS MUST ALSO APPLY TO ANY AND ALL DAMAGES SUSTAINED TO THE CABLES BY THE CONTRACTOR DURING INSTALLATION. 4. ALL SCS AND/OR LV INSTALLATIONS MUST BE PERFORMED BY TECHNICIANS QUALIFIED FOR THAT SYSTEM. THE LABOR EMPLOYED BY THE CONTRACTOR MUST BE REGULARLY EMPLOYED IN THE INSTALLATION AND REPAIR OF SCS AND/OR LV SYSTEMS AND MUST BE ACCEPTABLE TO THE OWNERS REPRESENTATIVE TO ENGAGE IN THE INSTALLATION AND SERVICE OF THIS SYSTEM. 5. THE MDF AND IDF SPACES ARE DESCRIBED BELOW, AND ENCOMPASS THE AREAS IN WHICH THE COMMUNICATIONS CABLING EXISTS. THESE AREAS INCLUDE (BUT ARE NOT LIMITED TO) THE BACKBOARDS, CABINETS, RACKS, FRAMES, LADDER RACKS, TERMINATION FIELDS, AND PATCH CORDS. THE SCS CONTRACTOR IS RESPONSIBLE FOR FOLLOWING THE STANDARDS, CODES AND LOCAL REGULATIONS FOR THESE SPACES, (E.G. ANSI/TIA-606, 607, AND 568 SERIES; NFPA 70 AND ALL APPLICABLE NEC ARTICLES; AND BICSI TDMM (CURRENT VERSION). 6. THE WIRING OF THE SYSTEM MUST BE EXECUTED IN ACCORDANCE WITH THE DRAWINGS AND THE EQUIPMENT MANUFACTURER'S WIRING DIAGRAMS. SHOULD ANY VARIATIONS IN THESE REQUIREMENTS OCCUR, THE CONTRACTOR MUST NOTIFY THE OWNERS REPRESENTATIVE BEFORE MAKING ANY CHANGES. IT MUST BE THE RESPONSIBILITY OF THE CONTRACTOR - AUTHORIZED INSTALLER OF THE APPROVED EQUIPMENT TO INSTALL THE EQUIPMENT AND GUARANTEE THE SYSTEM TO OPERATE AS PER PLANS AND SPECIFICATIONS. 7. ALL MATERIALS MUST BE NEW. NO USED OR RE-MANUFACTURED PARTS OR COMPONENTS WILL BE ACCEPTED. 8. CABLE STORAGE: THE CONTRACTOR MUST NOT ROLL OR STORE CABLE REELS WITHOUT AN APPROPRIATE UNDERLAY AND THE PRIOR WRITTEN APPROVAL OF OWNERS REPRESENTATIVE. 9. SPECIAL EQUIPMENT AND TOOLS: IN ORDER TO ENSURE THE LEAST AMOUNT OF CABLE UNTWISTING, IT IS REQUIRED THAT ALL CABLES MUST BE STRIPPED USING A CABLE MANUFACTURER'S RECOGNIZED SPECIAL TOOL. IT MUST BE THE RESPONSIBILITY OF THE CONTRACTOR TO FURNISH ANY SPECIAL INSTALLATION EQUIPMENT OR TOOLS NECESSARY TO PROPERLY COMPLETE THE SYSTEM. THIS MAY INCLUDE, BUT IS NOT LIMITED TO, TOOLS FOR TERMINATING CABLES, TESTING AND SPLICING EQUIPMENT FOR COPPER/FIBER CABLES, COMMUNICATION DEVICES, JACK STANDS FOR CABLE REELS, OR CABLE WINCHES. 10. UNDER NO CIRCUMSTANCE ARE "CHANNEL LOCKS" OR OTHER PLIERS NOT DESIGNED BY THE SCS MANUFACTURE BE USED TO TERMINATE JACKS OR INSERTS. B. TELECOMMUNICATION PATHWAY NOTES: 1. PATHWAYS CAN BE DIVIDED UP INTO TWO SEPARATE CATEGORIES, OUTSIDE PLANT (OSP) AND INSIDE PLANT (ISP). IT IS THE SCS AND/OR LV SYSTEM(S) CONTRACTOR'S RESPONSIBILITY TO IDENTIFY ALL EXISTING PATHWAYS (CONDUIT, CABLE TRAY, ETC) THAT WILL BE UTILIZED ON THE PROJECT, AND COORDINATE WITH THE ON-SITE ELECTRICAL OR GENERAL CONTRACTOR TO PROVE ALL PATHS SUBJECT TO BE USED ON THIS PROJECT BEFORE INSTALLATION. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF ALL UNDERGROUND (OSP) PATHWAYS, NON-ACCESSIBLE AND OPEN CEILING SPACE PATHWAYS AS DESCRIBED IN SECTION G, CONTRACTOR GUIDELINES OF THESE TELECOMMUNICATION GENERAL NOTES. 2. ALL PULLBOXES MUST BE SIZED AND INSTALLED PER ANSI/TIA-569-E STANDARDS. PULLBOXES FOR IN/UNDER SLAB CONDUIT RUNS ARE NOT PERMITTED UNLESS OTHERWISE NOTED. PULLBOXES FOR OVERHEAD CONDUIT RUNS MUST BE LOCATED ABOVE ACCESSIBLE CEILINGS WITHIN THE ACCESSIBLE CEILING SPACE AND SUPPORTED INDEPENDENTLY FROM THE STRUCTURE AND CONDUIT SUPPORTS. PULLBOXES FOR ROOF MOUNTED OR EXTERIOR ABOVE GRADE APPLICATIONS MUST BE NEMA 3R RATED. PULLBOXES MUST BE SIZED ACCORDING TO THE FOLLOWING: --CONTINUED-- 3. FOR ALL FIRESTOPPING OF SCS AND LV SYSTEMS PATHWAY RESPONSIBILITIES REFERENCE, PENETRATION OF WALLS, FLOOR AND CEILINGS SECTION OF THESE TELECOMMUNICATION GENERAL NOTES. 4. FOR ALL OTHER SCS AND/OR LV SYSTEMS PATHWAY RESPONSIBILITIES REFERENCE, CONTRACTOR GUIDELINES SECTION OF THESE TELECOMMUNICATION GENERAL NOTES. 5. OUTSIDE PLANT (OSP) PATHWAYS CAN BE BROKEN DOWN INTO THE FOLLOWING ITEMS, MAINTENANCE HOLES, HAND HOLES, PULLBOXES, AND CONDUITS. a. WHILE ENTERING MAINTENANCE HOLES, FOLLOW ALL CODES AND SAFETY PRACTICES OF A "CONFINED SPACE". UTILIZE NECESSARY EQUIPMENT TO MAINTAIN ALL SAFE PULLING TENSIONS FOR THE CABLES TO BE INSTALLED. THIS INFORMATION CAN BE FOUND ON THE CABLE MANUFACTURER'S SPECIFICATIONS SHEETS. b. BEFORE EXITING THE MAINTENANCE HOLE, NOTE ON PAPER OR DIGITAL MEANS THE EXISTING AND NEW CABLE(S) LOCATION(S) AND ROUTE(S), AND PROVIDE A "BUTTERFLY" PRINT TO AHJ AND OWNER'S REPRESENTATIVE. LABEL THE INSTALLED MEDIA PER SPECIFICATIONS. c. WITH DIRECTION OF OWNER OR OWNER'S REPRESENTATIVE, CHOOSE AND PROVE ALL CONDUITS BEFORE THE INSTALLATION OF THE MEDIA. MEASURE ALL PATHWAYS WITH MULE- TAPE PRIOR TO ORDERING MATERIAL. ALL LABOR AND MATERIAL COSTS ASSOCIATED WITH DISCREPANCIES BETWEEN DRAWINGS AND VERIFIABLE SITE CONDITIONS MUST BE BORNE BY CONTRACTOR. COORDINATE WITH THE ELECTRICAL OR GENERAL CONTRACTOR (EC OR GC), IF CONDUITS ARE PLUGGED OR MISSING PULL ROPE. --CONTINUED-- B. (CONT.) TELECOMMUNICATION PATHWAY NOTES: d. TRAIL ALL BACKBONE MEDIA (I.E. COPPER, FIBER OR INNERDUCT) WITH MULE TAPE, MINIMUM 1/2-INCH WIDE AND RATED FOR 2500 LBS WITH FOOTAGE MARK, LABEL AND TIE OFF BOTH ENDS, FOR FUTURE INSTALLATIONS. e. PROVIDE AND INSTALL ALL HARDWARE NECESSARY TO SUPPORT THE CABLING TO THE WALLS OF THE MAINTENANCE HOLE (IF IT DOES NOT ALREADY EXIST). THIS HARDWARE IS TO BE CONSTRUCTED FOR THE AREA IT IS TO BE INSTALLED AND DESIGNED FOR THE PURPOSE INTENDED FOR ITS USE. f. SCS AND/OR LV CONTRACTOR TO PROVIDE EXPANSION PLUGS IN ALL DUCTS/CONDUITS ENTERING THE BUILDING. SEAL ALL UNUSED DUCTS/CONDUITS WITH PLUGS THAT ALLOW THE PULL-STRING TO BE TIED OFF ON THE INSIDE. 6. INSIDE PLANT (ISP) PATHWAYS CAN BE BROKEN DOWN INTO THE FOLLOWING ITEMS, HOLLOW WALL PENETRATION, MEMBRANE PENETRATION, ACCESSIBLE CEILING (I.E. "J" HOOKS), AND CONDUIT. 7. CABLE RACEWAYS AND CONDUITS MUST NOT BE FILLED GREATER THAN FILL RATIO TABLES SHOWN. a. CONDUIT AND PATHWAY ROUTING SHOWN FOR THE SCS AND LV SYSTEMS ARE STRICTLY DIAGRAMMATICAL FOR THE PURPOSE OF THE BID TO ILLUSTRATE GENERAL METHODOLOGY. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO DETERMINE THE BEST MEANS & METHODS FOR SCS & TELECOMMUNICATION CONDUIT AND PATHWAY INSTALLATION. ADDITIONALLY IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO COORDINATE THE INSTALLATION PLAN WITH THE OWNERS REPRESENTATIVE AND ALL TRADES PRIOR TO INSTALLATION. REFER TO PLANS AND GENERAL ELECTRICAL SPECIFICATION FOR ADDITIONAL REQUIREMENTS. b. CONDUIT PATHWAYS MUST BE SUPPLIED BY THE ELECTRICAL OR GENERAL CONTRACTOR AS PER THE DRAWINGS, OTHER CONDUITS (IF ANY) MAY NEED TO BE COORDINATED WITH THE EC AND/OR GC OF THE PROJECT. c. NO CABLE IS TO BE PULLED THROUGH A CONDUIT L-BEND "LB" (CONDULETS) EXCEPT WHEN USING CATEGORY 6 RATED CONDULETS, AND ONLY WHERE SPECIFIED. d. ALL EXPOSED CONDUIT AND HARDWARE MUST BE PAINTED TO MATCH SURROUNDING SURFACES. CONTACT OWNER REPRESENTATIVE FOR PAINT COLORS. DO NOT PAINT CABLES. e. CONDUITS MUST CONTAIN PLASTIC OR NYLON PULL TAPE RATED AT 1250 LBS. WITH A MINIMUM OF 5 FEET OF EXTRA PULL TAPE COILED AT EACH END. f. TERMINATE CONDUIT STUBS AND SLEEVES THAT PROTRUDE THROUGH STRUCTURAL FLOORS 2"-3" ABOVE THE FLOOR SURFACE. g. INSTALL BUSHINGS AND BELL ENDS AS REQUIRED ON ALL CONDUITS. h. FLEX CONDUIT IS UNACCEPTABLE FOR USE AS A COMMUNICATIONS CONDUIT EXCEPT AT SEISMIC JOINTS AND/OR IF APPROVED IN WRITING BY THE ENGINEER. i. ALL UNDER SLAB OR IN-SLAB CONDUITS MUST BE INSTALLED IN A MANNER THAT PREVENTS WATER INFILTRATION OF THE CONDUIT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE GROUND WATER, RAIN WATER OR CONSTRUCTION WATER IS PREVENTED FROM ENTERING AND/OR REMOVED FROM THE CONDUITS PRIOR TO PLACEMENT OF COMMUNICATIONS CABLES. SEE ELECTRICAL SPECIFICATIONS, DETAILS AND PLANS FOR ADDITIONAL CONDUIT SEALING REQUIREMENTS. j. PROVIDE LABELING OF EACH CONDUIT PER GENERAL ELECTRICAL SPECIFICATIONS. k. REINSTALL PULL-STRINGS IN ALL SCS AND LV ISP PATHWAYS AFTER USE TO FACILITATE FUTURE ADDITION OF CABLES. l. IT IS THE SCS AND/OR LV CONTRACTOR'S RESPONSIBILITY TO REPORT ANY UNUSABLE OR INADEQUATE CONDUIT RUNS TO THE OWNER PRIOR TO PULLING ANY CABLE. m. PULL BOXES ARE NOT TO BE USED IN LIEU OF A BEND, AND THE CONDUIT MUST EXIT A PULLBOX ON THE WALL OPPOSITE THE WALL ENTERED. n. CONDUITS MUST; • CONTAIN NO CONTINUOUS SECTIONS LONGER THAN 30M (98 FT.) • CONTAIN NO MORE THAN (2) 90° BENDS OR (1) REVERSE BEND WITHOUT INSTALLING A PULLBOX SIZED PER STANDARDS & CODE. o. SPLIT CONDUITS IN PLACE OF PULLBOXES ARE UNACCEPTABLE. p. CONDUIT BEND RADIUS MUST BE; • A MINIMUM OF 6 TIMES THE INTERNAL CONDUIT DIAMETER FOR CONDUITS 2" IN DIAMETER OR LESS. • A MINIMUM OF 10 TIMES THE INTERNAL CONDUIT DIAMETER FOR CONDUITS MORE THAN 2" IN DIAMETER. q. ALL CABLES MUST BE PULLED AT THE SAME TIME TO ACHIEVE THE GREATEST FILL LEVELS. r. CONDUIT RUNS SHOULD BE LESS THAN 50 FEET IN LENGTH (REDUCE THE NUMBER OF CABLES BY 15% FOR CONDUIT RUNS BETWEEN 50 AND 100 FEET. s. PULL BOXES SHOULD BE PLACED EVERY 100 FEET OR IF MORE THAN 180 DEGREES OF BENDS ARE INSTALLED IN THE CONDUIT. --CONTINUED-- FOR FILL RATIO BASED CONDUIT SIZING REFER TO THE FILL RATIO TABLE 1A - 1B BELOW AND REFERENCE TO ANSI/TIA-569-E. 1 PULLBOX SIZING PER ANSI/TIA-569-E. CONDUIT SIZE WIDTH LENGTH DEPTH WIDTH INCREASE PER ADDITIONAL CONDUIT 1"4"15" 3"2" 2"8" 36" 4"5" 3"61" 48" 5"6" 4"101" 60" 8"8" FILL RATIO TABLE 1A - Conduit CONDUIT SIZE .13 3/4"16 1" 1 1/4" 1 1/2" .18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .37 .39 2" 2 1/2" 3" 3 1/2" 4" 18 7 6 6 5 5 4 4 4 3 3 3 3 2 2 2 2 2 1 26 213 12 11 9 9 8 7 7 6 6 5 5 4 4 4 4 3 3 3 45 523 21 19 17 15 14 13 12 11 10 9 9 8 7 7 6 6 6 5 61 632 28 25 23 21 19 18 16 15 14 13 12 11 10 10 9 8 8 7 101 1152 47 42 38 35 32 29 27 25 23 21 20 18 17 16 15 14 13 12 176 1992 82 74 67 61 56 51 47 44 40 38 35 33 31 29 27 25 24 21 266 29139 124 112 102 93 85 78 72 66 61 57 53 50 46 43 41 38 36 32 347 38181 162 146 133 121 111 102 94 86 80 74 69 65 61 57 53 50 47 42 444 49231 208 187 170 155 142 130 120 111 103 95 89 83 78 73 68 64 61 54 FILL RATIO TABLE 1B - CONDUIT (EMT EXAMPLE) CONDUIT SIZE .41 3/4"1 1" 1 1/4" 1 1/2" .45 .49 .51 .55 .59 .61 .65 .69 .71 .75 .79 .85 .98 1.001.321.581.792.182.63 3.00 (47%) 2" 2 1/2" 3" 3 1/2" 4" 1 1 1 - - - - - - - - - - - - - - - - - 2 2 1 1 1 1 1 1 - - - - - - - - - - - - - 4 3 3 2 2 2 2 1 1 1 1 1 1 6 5 4 3 3 2 2 2 2 2 1 1 1 1 1 - - - - - - - - - - - - - - 10 8 7 6 5 4 4 4 3 1 13 3 2 2 17 14 12 11 9 8 8 7 6 3 25 4 45 1 1 26 22 18 17 14 12 12 10 9 4 48 7 68 2 1 34 29 24 22 19 16 15 13 12 6 5119 810 3 2 2 1 44 37 31 28 24 21 20 17 15 7 714 12 1013 4 3 2 1 1 1 - - - - - - - - - - - - - - - - FILL RATIO TABLE 2A - Cable Tray / Wire Basket / Raceway per NEC 2017 Article 725 TRAY SIZE (WXD) 4x4 482 6x4 12x4 18x4 24x4 6x6 12x6 18x6 24x6 251 225 203 184 723 377 338 305 277 252 231 212 1447754 677 661 554 505 462 424 391 361 335 311 290 271 254 238 224 217011321016 917 831 758 693 636 587 542 503 467 436 407 381 358 336 289415091355122211091010 924 849 782 732 671 623 581 543 509 477 449 1085566 508 458 415 379 346 318 293 271 251 233 218 203 190 179 168 217011321016 917 831 758 693 636 587 542 503 467 436 407 381 358 336 3256 361169815241375124711371040 955 880 814 754 701 654 611 572 537 505 476 449 401 4341 4822264203218341663151613871273117410851006 935 872 815 763 716 673 634 598 535 168 154 141 130 120 111 103 96 90 84 79 74 70 66 59 53 195 180 167 155 145 135 127 119 112 105 99 89 80 211 199 178 160 317 299 267 241 423 399 357 321 158 149 133 120 317 299 267 241 .13 .18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .37 .39 PATHWAY SEPARATION FROM SOURCE OF ELECTROMAGNETIC ENERGY: CONDITION <2KVA 2-5 KVA >5KVA Unshielded Power Lines in Proximity to open PVC Pathways 6" (In.)12" (In.) 24" (In.) Unshielded Power Lines in Proximity to Grounded Metallic Pathways 3" (In.) 6" (In.) 12" (In.) Power Lines enclosed in Metal Grounded Pathways in proximity to Grounded Metallic Pathways <1" (In.) 3" (In.) 6" (In.) B. (CONT.) TELECOMMUNICATION PATHWAY NOTES: t. POWER SEPARATION: • THE CONTRACTOR MUST NOT PLACE ANY DISTRIBUTION CABLING ALONGSIDE POWER LINES, OR SHARE THE SAME CONDUIT, CHANNEL OR SLEEVE WITH ELECTRICAL APPARATUS. AT NO POINT MUST THE COMMUNICATIONS CABLES BE TIED TO POWER CABLES OR OTHER BUILDING SERVICES. STATION CABLES AND TIE CABLES INSTALLED WITHIN CEILING SPACES MUST BE ROUTED THROUGH THESE SPACES AT RIGHT ANGLES TO ELECTRICAL POWER CIRCUITS. • AVOID ELECTROMAGNETIC INTERFERENCE (EMI) BY MAINTAINING ADEQUATE PHYSICAL SEPARATION BETWEEN TELECOMMUNICATION CABLING AND POSSIBLE SOURCES SUCH AS, BUT NOT LIMITED TO, ELECTRIC MOTORS, ELECTRIC PENCIL SHARPENERS, TRANSFORMERS, FLUORESCENT LIGHTS THAT SHARE DISTRIBUTION SPACE WITH TELECOMMUNICATIONS CABLING, COPIERS THAT SHARE WORK AREA SPACE WITH LINE CORDS AND TERMINALS, LARGE FAX MACHINES AND POWER CORDS THAT SUPPORTS SUCH EQUIPMENT. C. TELECOMMUNICATION CABLING NOTES: 1. THE USE OF LUBRICANTS SUCH AS CLEAR GLIDE, TO FACILITATE THE INSTALLATION OF CABLES IN OUTDOOR CONDUITS IS ENCOURAGED FOR FRICTION REDUCTION AND TO MAINTAIN THE REQUIRED PULL TENSION. YELLOW 77 AND POLYWATER IS NOT PERMISSIBLE FOR USE AS A LUBRICANT FOR TELECOMMUNICATION CABLING. THE USE OF OSP, LOW TEMPERATURE CABLE LUBRICANTS ARE NOT ACCEPTABLE IN AN INDOOR PLENUM ENVIRONMENT. UNDER NO CIRCUMSTANCES MUST CABLE PULLING LUBRICANT BE ALLOWED TO ACCUMULATE ON WALLS, FLOORS, BACKBOARDS, OR OTHER SURFACES OUTSIDE THE CONDUIT. 2. ANY CABLE DAMAGED OR EXCEEDING RECOMMENDED INSTALLATION PARAMETERS DURING INSTALLATION MUST BE REPLACED BY THE CONTRACTOR BEFORE FINAL ACCEPTANCE AT NO COST TO THE OWNER. 3. EACH RUN OF CABLE BETWEEN THE TERMINATION BLOCK OR PATCH PANEL AND THE STATION CONNECTOR MUST BE CONTINUOUS WITHOUT ANY JOINTS OR SPLICES. 4. ALL STATION CABLE MUST BE PLACED IN THE INTERIOR OF WALLS UNLESS OTHERWISE NOTED OR OBSTRUCTED. 5. PROVIDE BUSHINGS, GROMMETS AND STRAIN-RELIEF FOR CABLES TERMINATING AT WALL- MOUNTED OUTLETS AND PATCH PANELS TO ENSURE DURABLE AND ROBUST CONNECTIONS. THE BUSHINGS AND GROMMETS ARE INTENDED TO PROTECT THE CABLES FROM ANY SHARP EDGES THAT PRESENT A RISK TO THE CABLES. ENSURE THAT ALL SHARP EDGES ARE COVERED TO PROTECT THE CABLES FROM DAMAGE. 6. ALL CABLE BUNDLES EXITING FLOOR OR WALL PENETRATIONS AND RUNNING INTO FURNITURE OR CASEWORK MUST BE WRAPPED IN SPIRAL WRAP OR SPLIT-LOOM TUBING TO PROTECT THE CABLING AND PROVIDE A NEAT INSTALLATION. 7. ALL CABLE OR INNERDUCT MUST RUN PARALLEL OR AT RIGHT ANGLES TO BUILDING WALL STRUCTURES. 8. IN SUSPENDED CEILING AND RAISED FLOOR AREAS WHERE DUCT, CABLE TRAYS OR CONDUIT ARE NOT AVAILABLE, CABLE BUNDLES MUST BE SUPPORTED VIA "J" HOOKS ATTACHED TO THE BUILDING STRUCTURE AND FRAMEWORK AT A MAXIMUM OF FOUR (4) FOOT INTERVALS. MINIMUM 1” WIDE J-HOOKS MUST BE APPROPRIATELY SIZED TO ALLOW A MINIMUM OF 60% SPARE CAPACITY FOR FUTURE CABLE INSTALLATION. THE CONTRACTOR MUST INCLUDE ALL COSTS IN BASE BID FOR ANY ADDITIONAL SUPPORTS/SEISMIC BRACING REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 9. THE CONTRACTOR MUST BUNDLE, IN BUNDLES OF 24 OR LESS, STATION OR OTHER CABLING WITH 3/4" HOOK AND LOOP STRIPS SIMILAR TO VELCRO "ONE WRAP", TIGHT ENOUGH TO HOLD THE BUNDLE TOGETHER IN A CYLINDRICAL SHAPE, BUT NOT SO TIGHT AS TO DEFORM THE CABLE GEOMETRY. IT MUST BE POSSIBLE TO COMPLETELY ROTATE ALL HOOK AND LOOP TIES AROUND ALL CABLE BUNDLES. PLENUM RATED HOOK AND LOOP TIES WILL BE USED IN ANY PLENUM AREAS. 10. CABLES OR J-HOOKS MUST NOT BE ATTACHED TO LIFT OUT CEILING GRID SUPPORTS OR LAID DIRECTLY ON THE CEILING GRID. 11. CABLES OR J-HOOKS MUST NOT BE ATTACHED TO OR SUPPORTED BY FIRE SPRINKLER HEADS OR DELIVERY SYSTEMS OR ANY ENVIRONMENTAL SENSOR LOCATED IN THE CEILING AIR SPACE. 12. WHERE ADDITIONAL CONDUIT(S)/SLEEVE(S) ARE REQUIRED, BUT NOT PROVIDED BY THE ELECTRICAL CONTRACTOR, THE SCS AND/OR LV CONTRACTOR MUST BE RESPONSIBLE TO PROVIDE SUCH CONDUIT(S)/SLEEVE(S). CONDUIT(S) AND SLEEVE(S) MUST BE OF SUITABLE MATERIAL, SIZED, INSTALLED, FIRE-STOPPED, AND GROUNDED AS REQUIRED BY THE NEC 2020, ANSI/TIA-569-E STANDARD AND ALL OTHER APPLICABLE CODES AND STANDARDS. SLEEVES MUST CONSIST OF METALLIC CONDUIT DE-BURRED AND GROMMETTED ON BOTH ENDS WITH FLANGES OR OTHER MEANS TO PREVENT THE SLEEVE FROM SLIPPING OR FALLING OUT OF THE PARTITION. SLEEVES MUST EXTEND A MINIMUM OF 6" ON BOTH SIDES OF THE PARTITION. OUTSIDE PERIMETER OF SLEEVES MUST BE SEALED AGAINST SOUND, AIR, WATER, HEAT, OR AS REQUIRED BY PARTITION DESIGN. INSIDE OF SLEEVE MUST BE SEALED SIMILARLY AFTER INSTALLATION OF ALL CABLING. CABLES MUST BE INDEPENDENTLY SUPPORTED ON EITHER SIDE OF THE SLEEVE. SLEEVES MUST NOT BE USED AS CABLE SUPPORTS. ANY CONDUIT(S) AND SLEEVE(S) ADDED BY THE SCS CONTRACTOR MUST BE APPROVED BY THE OWNERS REPRESENTATIVE PRIOR TO ROUGH-IN. 13. IN THE EVENT CONTRACTOR IS REQUIRED TO REMOVE CEILING TILES, SUCH WORK MUST NOT BREAK OR DISTURB GRID. REMOVAL OF THE CEILING GRID MUST BE COORDINATED WITH THE OWNERS REPRESENTATIVE. ALL INSULATION MUST BE REPLACED IN ITS ORIGINAL LOCATION. --CONTINUED-- 14. THE NUMBER OF CABLES IN EACH CONDUIT MUST BE CONTROLLED TO ALLOW FOR FUTURE CABLE INSTALLATION AND TO STAY WITHIN THE MANUFACTURER'S MAXIMUM ALLOWABLE CABLE PULLING TENSION. CONDUIT FILL RATIOS MUST NOT EXCEED THE CURRENT REQUIREMENTS OF THE NEC 2020, ANSI/TIA-569-E, REFERENCE SECTION B.2, TABLES 1 AND 2 OF THIS DOCUMENT FOR ADDITIONAL REQUIREMENTS. 15. CONDUITS: • ALL BACKBONE CABLING WILL RUN THROUGH DEDICATED CONDUITS. • ALL NEW CONDUITS WILL BE SUPPLIED WITH A PULL STRING BY THE ELECTRICAL CONTRACTOR. • EXISTING CONDUITS MUST BE PROVEN TO BE CLEAR BY THE SCS AND/OR LV CONTRACTOR PRIOR TO PULLING OF CABLES. • SCS AND/OR LV CONTRACTOR MUST SUPPLY PULL STRING AND PULL ROPE FOR THE INSTALLATION OF ALL CABLES IN EXISTING CONDUITS. • FOR ALL CONDUITS LEFT WITH AVAILABLE CAPACITY, SCS AND/OR LV CONTRACTOR MUST REPLACE PULL STRINGS DURING THE COURSE OF WORK. • SCS AND/OR LV CONTRACTOR MUST SEAL ALL CONDUITS WITH AN APPROVED SEALING COMPOUND. D. TELECOMMUNICATION GROUNDING SYSTEM NOTES. 1. THE ELECTRICAL CONTRACTOR MUST PROVIDE A TELECOMMUNICATION GROUNDING BUSSBAR (PBB) AND TELECOMMUNICATION BONDING BACKBONE (SBB) CABLE(S) AT EACH MDF ROOM AND IDF LOCATION. TERMINATE THE SBB ON GROUND BARS LOCATED AT EACH MDF ROOM AND IDF CABINET FROM BUILDING STEEL OR MAIN ELECTRICAL GROUND, OR AS OTHERWISE INDICATED ON THE DRAWINGS. 2. THE SCS CONTRACTOR MUST UTILIZE A TELECOMMUNICATIONS BONDING BACKBONE (SBB) AS INDICATED IN THE DRAWINGS. GROUNDING MUST BE IN ACCORDANCE WITH THE NEC 2020, ANSI/TIA-607-E.1 AND ALL LOCAL CODES AND PRACTICES. 3. THE SCS CONTRACTOR MUST BE RESPONSIBLE FOR BONDING ALL METALLIC SHEATH COMMUNICATIONS CABLES ENTERING THE BUILDING PER MANUFACTURER SPECIFICATIONS AND NEC 770-33, 800-33 AND 800-40. ALL GROUNDS MUST CONSIST OF A COLOR GREEN #6-AWG COPPER WIRE AND MUST BE SUPPLIED FROM AN APPROVED BUILDING GROUND AND BONDED TO THE MAIN ELECTRICAL GROUND. ALL CABLE SHEATHS AND SPLICE CASES MUST BE GROUNDED TO A TELECOMMUNICATIONS GROUND BUS. 4. THE SCS CONTRACTOR MUST PROVIDE GROUNDING AND BONDING FROM ALL HORIZONTAL EQUIPMENT INCLUDING DISTRIBUTION AND CROSS CONNECT FRAMES, PATCH PANELS, CABLE TRAYS, EQUIPMENT RACKS, LADDER TRAYS, CONDUITS, ACTIVE TELECOMMUNICATION EQUIPMENT, SLEEVES, TEST APPARATUS. EQUIPMENT MUST BE BONDED TO THE SBB GROUND BARS UTILIZING A #6-AWG GREEN CONDUCTOR WITH 2-HOLE LONG BARREL COMPRESSION GROUNDING LUGS. a. EACH EQUIPMENT CABINET AND RACK REQUIRES ITS OWN DEDICATED RACK GROUNDING BUSBAR (RGB) WITH A BONDING CONNECTION TO THE GROUNDING INFRASTRUCTURE. THE GROUNDING INFRASTRUCTURE CONSIST OF A SBB, BY PROVIDING EVERY RACK/CABINET WITH ITS OWN DEDICATED #6 AWG (MIN.) GREEN CONDUCTORS BACK TO THE TMGB (TELECOMMUNICATIONS MAIN GROUNDING BUSBAR) / PBB (PRIMARY BUS BAR). ALL GROUND CONDUCTOR ATTACHMENTS MUST UTILIZE 2-HOLE LONG BARREL COMPRESSION LUGS. b. HORIZONTAL CABLES MUST BE GROUNDED IN COMPLIANCE WITH NFPA 70 (NEC) AND LOCAL REQUIREMENTS AND PRACTICES. c. IN RAISED-FLOOR ENVIRONMENTS, THE GROUND CONDUCTOR MUST ATTACH TO THE LOWEST HOLES ON THE FRONT RAIL OF EACH RACK/CABINET. d. RACK MOUNTED EQUIPMENT MUST BE GROUNDED VIA THE CHASSIS, IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. e. BONDING OF LADDER RACK SECTIONS: ATTACH BONDING STRAPS TO EACH LADDER RACK SECTION BY UTILIZING EITHER TWO (2) TRI- LOBULAR THREAD-FORMING SCREWS (NOT SELF-TAPPING OR SHEET METAL SCREWS) OR BY USING TWO (2) STANDARD BOLTS WITH TWO (2) "TYPE B" INTERNAL / EXTERNAL TOOTH LOCK WASHERS PER BOLT. IF THREAD-FORMING SCREWS ARE NOT USED, REMOVE PAINT AT EACH CONNECTION POINT AND USE AN APPROVED ANTI-OXIDANT PRIOR TO ATTACHING THE BONDING STRAP. E. TERMINAL BACKBOARDS NOTES. 1. WHERE INDICATED ON DRAWINGS, ELECTRICAL CONTRACTOR TO PROVIDE NEW PLYWOOD TERMINAL BACKBOARDS. USE DOUGLAS FIR PLYWOOD, INTERIOR A/C GRADE, FINISHED ONE SIDE AND PRIME COAT PAINTED ON ALL SURFACES WITH A FINISH COAT OF FIRE RETARDANT WHITE ENAMEL. ON EACH PLYWOOD SHEET LEAVE ONE (1) FIRE MARSHAL STAMP UNPAINTED FOR INSPECTION. UNLESS OTHERWISE INDICATED, USE 8'-0" HIGH X LENGTH AS SHOWN ON DRAWINGS X 3/4" THICK PLYWOOD. REFERENCE BACKBOARD ELEVATIONS FOR MORE INFORMATION. F. PENETRATIONS OF WALLS, FLOORS AND CEILINGS NOTES. 1. UNLESS SPECIFICALLY SHOWN ON THE DRAWINGS, THE CONTRACTOR MUST MAKE NO PENETRATION OF FLOORS, WALLS OR CEILING WITHOUT THE PRIOR WRITTEN APPROVAL OF THE OWNERS REPRESENTATIVE. 2. WALL PENETRATIONS: a. THE SCS AND/OR LV CONTRACTOR MUST PROVIDE FIRE STOPPING FOR ALL COMMUNICATIONS RATED (AND IN SOME CASES NON-RATED, THAT WILL BE DESCRIBED BELOW THIS SECTION) PATHWAYS AND SPACES. THESE FIRE STOPPING DEVICES MUST CONFORM TO (BUT NOT LIMITED TO) UL 1479, ASTM E814, BICSI TDMM, FIRE STOPPING, ANSI/TIA-568.0-E, ANSI/TIA-569-E, ANSI/TIA-569 ANNEX A AND TDMM 14TH EDITION - FIRESTOPPING CHAPTER, STANDARD FOR INSTALLING COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING, SECTION 5, CLAUSE 5.1 THROUGH 5.2.3, MANUFACTURES GUIDELINES OR OTHER PREVAILING CODE AND MUST BE AN APPROVED UL LISTED SYSTEM. --CONTINUED-- b. CABLE TRAY FIRE-STOPPING MUST UTILIZE THE MULTI GANG FIRE-STOPPING SYSTEM THAT WILL BE ABLE TO STACK THE UNITS HORIZONTALLY AND/OR VERTICALLY IF REQUIRED DUE TO CURRENT AND/OR FUTURE CABLING DESIGNS. c. THE CONTRACTOR MUST INSTALL PENETRATION FIRE-STOP SEAL MATERIALS IN ACCORDANCE WITH DESIGN REQUIREMENTS, AND MANUFACTURER'S INSTRUCTIONS. d. THE CONTRACTOR'S INSTALLER MUST BE CERTIFIED, LICENSED OR OTHERWISE QUALIFIED BY THE FIRE-STOPPING MANUFACTURER AS HAVING BEEN PROVIDED THE NECESSARY TRAINING TO INSTALL MANUFACTURER'S PRODUCTS PER SPECIFIED REQUIREMENTS. e. ALL THROUGH-PENETRATION MUST BE A MANUFACTURED, UL CLASSIFIED, FIRE-STOP DEVICE / SYSTEM DESIGNED TO ALLOW CABLES TO PENETRATE FIRE-RATED WALLS WITH A BUILT-IN FIRE SEALING SYSTEM THAT AUTOMATICALLY ADJUSTS TO THE AMOUNT OF CABLES INSTALLED. THE FIRE-STOPPING DEVICE MUST BE CAPABLE OF INSTALLATION IN NEW CONSTRUCTION OR RETROFIT IN EXISTING STRUCTURES. f. THE CONTRACTOR MUST NOT USE CONCRETE OR OTHER NON-REMOVABLE SUBSTANCE FOR FIRE STOPPING ON CABLE TRAYS, WIREWAYS OR CONDUITS. CONTRACTORS WHO USE THIS METHOD WILL BE REQUIRED TO REPLACE ALL CABLES AFFECTED AND PROVIDE THE ORIGINAL SPECIFIED ACCESS TO EACH EFFECTED AREA. THIS REQUIREMENT ALSO APPLIES TO MAINTAINING FIRE RATINGS OF ALL FLOORS PENETRATED BY CONDUITS OR DEVICES DESIGNATED FOR USE BY VOICE AND DATA CABLING. g. ANY PENETRATIONS THROUGH FIRE-RATED WALLS FOR CABLE PATHWAYS / CABLES MUST BE SEALED BY USE OF A NON-PERMANENT FIRE BLANKET OR OTHER METHOD IN COMPLIANCE. THE CONTRACTOR MUST USE FIRE STOPPING ON CABLE TRAYS, WIREWAYS AND CONDUITS EITHER VERTICAL OR HORIZONTAL. FOUR DIFFERENT METHODS OF FIRE-STOPPING HAVE BEEN IDENTIFIED FOR THE HORIZONTAL THROUGH PENETRATIONS BETWEEN WALLS, RATED, RATED WITH ACOUSTIC PROPERTIES, NON-RATED, AND NON-RATED WITH ACOUSTIC PROPERTIES. BELOW ARE METHODS TO ACCOMPLISH THESE DIFFERENT TYPES: • SEALING OF RATED OPENINGS BETWEEN FLOORS OR THROUGH RATED WALLS, WHETHER EXISTING OR CREATED BY THE CONTRACTOR FOR PLACEMENT OF CABLE MUST BE THE RESPONSIBILITY OF THE CONTRACTOR. SEALING MATERIAL AND APPLICATION MUST BE AN APPROVED UL LISTED SYSTEM AND MUST BE ACCOMPLISHED IN SUCH A MANNER THAT IS ACCEPTABLE TO THE LOCAL FIRE AND BUILDING AUTHORITIES HAVING JURISDICTION OVER THIS WORK. CREATION OF SUCH OPENINGS AS ARE NECESSARY FOR CABLE PASSAGE BETWEEN LOCATIONS AS SHOWN ON THE DRAWINGS MUST BE THE RESPONSIBILITY OF THE CONTRACTOR. ANY OPENINGS CREATED BY OR FOR THE CONTRACTOR AND LEFT UNUSED MUST ALSO BE SEALED AS PART OF THIS WORK. • RATED WALLS WITH THROUGH PENETRATIONS WITH ACOUSTIC PROPERTIES MUST BE INSTALLED WITH FACTORY MANUFACTURED DEVICE. SUCH AS A STI "EZ PATH" OR WIREMOLD "FLAMESTOPPER" OR EQUAL. THE TYPICAL STC RATING IS TO BE EQUAL TO OR GREATER THAN THE WALL PENETRATED, (AVG IS A RATING OF 44 STC PER UBC RATINGS). • NON-RATED PATHWAY, ALTHOUGH NOT REQUIRED TO BE FIRE-STOPPED, MUST BE A MANUFACTURED DEVICE THAT WILL ALLOW FIRE-STOPPING TO BE INSTALLED IN THE FUTURE IF REQUIRED, (I.E. WIREMOLD “FLAMESTOPPER” OR EQUAL). • A NON-RATED PATHWAY WITH ACOUSTIC PROPERTIES CAN BE FOUND IN AREAS SUCH AS, CONFERENCE ROOMS, HUMAN RESOURCE OFFICES, MEDICAL EXAMINATION ROOMS ETC. THESE ROOMS REQUIRE TO LIMIT THE AMOUNT OF AMBIENT NOISE THAT CAN TRAVEL FROM ONE ROOM TO THE OTHER THROUGH THE CEILING GRID. IF THIS WALL IS PENETRATED, INSTALL A SYSTEM THAT WILL RE-ESTABLISH THE STC RATING OF THE WALL, THE TYPICAL STC RATING IS AN AVERAGE OF 44 STC PER UBC RATINGS. -CONTINUED-- 23. LADDER RACK MUST BE PLACED IN MDF AND IDF(S) AS SHOWN ON DRAWINGS AND AS REQUIRED TO PROPERLY SECURE CABLES AND WIRE. 24. A BACKBONE CABLE ASSIGNMENT RECORD SHEET MUST BE PREPARED (TYPED) PRIOR TO START OF ACCEPTANCE TESTING. ALL FLOOR PLANS MUST BE NEATLY HAND NOTED WITH STATION JACK NUMBER AND CABLE LENGTH. 25. ALL CABLES MUST BE CLEARLY LABELED WITH CABLE NUMBERS, PAIR ASSIGNMENTS AND DESIGNATION. 26. ALL CABLE TRAYS, LADDER RACKS, CONDUITS, EQUIPMENT RACKS, PROTECTOR PANELS, AND CABLE SHEATHS MUST BE BONDED & GROUNDED TO EQUIPMENT GROUND WITH #6 WIRE (MIN.) 27. ALL SPLICES MUST BE CONTAINED WITHIN AN APPROVED SPLICE CASE DESIGNED FOR MULTIPLE CLOSURE. 28. ALL SPLICES MUST UTILIZE 3M 710 MODULES. ALL CABLES MUST BE EQUIPPED TO PROVIDE A CONTINUOUS BOUND OF CABLE SHIELDS THROUGH ALL SPLICES. 29. PULL TAPES MUST BE PLACED IN ALL VACANT CONDUITS. 30. ALL WORK MUST BE COMPLETED IN A NEAT AND PROFESSIONAL MANNER. THE WORK SITE MUST BE KEPT CLEAN AND ALL DAMAGE TO OWNER'S PROPERTY REPAIRED. 31. THE CONTRACTOR MUST BE RESPONSIBLE FOR CONDUCTING A FINAL CLEANUP OF THE WORK SITE PRIOR TO FINAL SYSTEM ACCEPTANCE. 32. CONTRACTOR MUST REMOVE ALL COPPER, FIBER AND COAXIAL CABLES ABANDONED IN CONDUIT, CEILINGS AND WALLS PER NEC. CABLE MUST INCLUDE ALL INTRABUILDING, RISER SYSTEMS AND STATION CABLES FOR ALL LOW VOLTAGE/TELECOMMUNICATION/STRUCTURED CABLING SYSTEMS. 33. CONTRACTOR(S) MUST VERIFY ALL SITE CONDITIONS PRIOR TO BID. 34. IN ACCESSIBLE CEILING SPACES; a. THE ELECTRICAL CONTRACTOR MUST PROVIDE THE REQUIRED STUB UP(S) / OUT(S) AND BOXES WITH MUD-RINGS TO THE NEAREST ACCESSIBLE CEILING SPACE AND / OR NEAREST TELECOMMUNICATION PATHWAY INFRASTRUCTURE, REFERENCE PLANS AND SPECIFICATION FOR MORE INFORMATION. b. THE DESIGNATED SCS / TELECOMMUNICATION CONTRACTOR(S) MUST PROVIDE A J-HOOK PATHWAY SYSTEM AND REQUIRED SLEEVES. DO NOT USE CEILING TILE WIRE HANGERS, WATER OR ELECTRICAL PIPES, OR LIGHT FIXTURES TO HANG CABLE. CABLE MUST BE A MINIMUM OF 6 INCHES ABOVE THE CEILING TILE AND MUST NOT COME WITHIN TWELVE INCHES OF A LIGHT FIXTURE. • THE SCS / TELECOMMUNICATION CONTRACTOR WILL PROVIDE THE PATHWAY REQUIRED FOR THE STRUCTURE CABLING SYSTEMS. • THE DESIGNATED LOW VOLTAGE / TELECOMMUNICATION CONTRACTOR(S) FOR EACH SUB-SYSTEM WILL PROVIDE THE PATHWAY REQUIRED FOR THE SYSTEMS, OUTSIDE WHAT IS CONSIDERED THE STRUCTURED CABLING SYSTEM. 35. IN INACCESSIBLE AND HARD LID CEILING SPACES; a. THE ELECTRICAL CONTRACTOR MUST PROVIDE ALL CONDUIT PATHWAYS, BOXES ETC. FOR A COMPLETE SYSTEM FROM THE MDF ROOM, IDF ROOM(S), IDF CABINET(S), AND ALL OTHER LOW VOLTAGE / TELECOMMUNICATION SYSTEMS HEADEND, CABINETS, TERMINAL CABINETS, ETC. TO THE POINT OF TERMINATION AT THE STATION END LOCATION PER PLANS AND SPECIFICATION. --END-- G. CONTRACTOR(S) GUIDELINES. 1. ALL TELECOMMUNICATION WORK MUST COMPLY WITH APPLICABLE FEDERAL, STATE, AND LOCAL CODES. WHERE THE CONSTRUCTION DOCUMENTS INDICATE MORE RESTRICTIVE REQUIREMENTS, THE DOCUMENTS MUST GOVERN BUT THE CONSTRUCTION DOCUMENTS MUST NOT BE INTERPRETED AS AUTHORITY TO VIOLATE ANY CODE OR REGULATION. 2. IN THE EVENT OF A CONFLICT OR INCONSISTENCY BETWEEN ITEMS INDICATED ON THE PLANS AND/OR SPECIFICATIONS OR WITH CODE REQUIREMENTS, THE NOTE, CODE OR SPECIFICATION WHICH PRESCRIBES AND ESTABLISHES THE MORE COMPLETE JOB OR THE HIGHER STANDARD MUST PREVAIL. 3. OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS OR THE MIS-DESCRIPTION OF DETAILS OF WORK WHICH ARE CLEAR AND NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, MUST NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK BUT THEY MUST BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. 4. THE CONTRACTOR MUST CHECK ALL DRAWINGS FURNISHED, IMMEDIATELY UPON THEIR RECEIPT AND MUST PROMPTLY NOTIFY THE OWNER OF ANY DISCREPANCIES. 5. ALL MATERIALS AND EQUIPMENT MUST BE NEW AND MUST BEAR THE UNDERWRITERS LABEL (UL) AND MUST BE INSTALLED IN THE MANNER FOR WHICH THEY ARE DESIGNED AND APPROVED. 6. THE CONTRACTOR MUST NOT BORE, NOTCH OR IN ANY WAY CUT INTO ANY STRUCTURAL MEMBER WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT OR STRUCTURAL ENGINEER. 7. ALL CHANGES TO STRUCTURES (BUILDING, DRILLING, CORING, ETC.) NOT SHOWN ON THE DRAWINGS MUST BE APPROVED IN WRITING BY STRUCTURAL ENGINEER. 8. FOR PURPOSES OF CLEARNESS AND LEGIBILITY, THE TELECOM DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC. THE SIZE AND LOCATION OF EQUIPMENT IS SHOWN TO SCALE WHEREVER POSSIBLE. THE CONTRACTOR MUST VERIFY ALL CONDITIONS, DATA INFORMATION AS INDICATED ON THE DRAWINGS AND IN THE SPECIFICATION SECTIONS WHERE SCS AND LOW VOLTAGE WORK INTERFACES WITH OTHER TRADES. 9. THE CONTRACTOR MUST MAINTAIN AS-BUILT DRAWINGS TO REFLECT ALL CHANGES MADE DURING CONSTRUCTION AND ANY DEVIATIONS FROM THE ELECTRICAL AND TELECOMMUNICATION DRAWINGS. THIS INCLUDES DEVIATIONS FROM OUTLET NUMBERS AND ANY ADDITION, DELETION OR RELOCATION OF OUTLETS SHOWN ON WORKING DRAWINGS, PATHWAY ADDITIONS, DELETIONS OR RELOCATIONS. THE CONTRACTOR MUST AFTER COMPLETION OF JOB, PROVIDE THE OWNER AN ELECTRONIC AND HARD COPY OF AS-BUILT WORK. 10. ANY DEVIATIONS FROM PLANS OR SPECS MUST BE APPROVED IN WRITING BY THE OWNER'S REPRESENTATIVE. 11. ALL FOOTAGES ON DRAWINGS ARE ESTIMATED AND MUST BE VERIFIED BY CONTRACTOR PRIOR TO ORDERING MATERIAL. 12. ALL STATION CABLES MUST BE NEATLY DRESSED AND SECURED EVERY FIVE FEET AT A MINIMUM. 13. THE CONTRACTOR MUST BE RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF CEILING TILE INCLUDING REPLACEMENT OF BROKEN OR DAMAGED TILES. 14. ALL LOCATIONS PASSING THROUGH A FIRE OR A SMOKE BARRIER MUST BE FIRE STOPPED USING APPROVED (UL CLASSIFIED) FIRE STOP SYSTEM, INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS AND PROPERLY LABELED. 15. CONDUIT MUST BE FILLED TO MAXIMUM CAPACITY (PER CODE, STANDARDS, AND NORMS) BEFORE UTILIZING ANOTHER VACANT CONDUIT. 16. ALL STATION OUTLETS AND TERMINALS MUST BE PROPERLY IDENTIFIED USING THE OWNER'S STANDARD INTERNAL DISTRIBUTION NUMBERING SCHEME. ALL LABELS MUST BE PREPRINTED OR TYPED. 17. EACH BACKBONE RISER AND/OR OSP CABLE MUST BE EQUIPPED WITH A PERMANENT LABEL INDICATING CABLE TYPE, PAIR OR OPTIC COUNTS, DISTANT ENDS, AND CABLE LENGTH. BOTH ENDS OF EACH CABLE AND AT EVERY MAINTENANCE HOLE, HAND HOLE, AND PULL BOX, MUST BE SO LABELED. 18. FIBER BACKBONE CABLE MUST BE PLACED WITH 6 FOOT MAINTENANCE LOOP AT BOTH ENDS OF THE RUN. THE MAINTENANCE LOOP MUST BE SECURED IN SUCH A MANNER TO PROVIDE PROTECTION DURING SUBSEQUENT CABLE PULLS. 19. ALL STATION CABLES/OUTLETS MUST BE TESTED AND DOCUMENTED USING A PAIR SCANNER SPECIFICALLY DESIGNED TO TEST THE TYPE OF CABLE INSTALLED (E.G. CATEGORY 6A). TEST RESULTS MUST BE ONE PAGE PER AND NOTED WITH THE STATION/JACK NUMBERING SCHEME THAT IS STANDARDIZED FOR THE OWNER. 20. ALL FIBER OPTIC STATION AND RISER CABLE MUST BE TESTED END-TO-END AND THE RESULTS (LOSS IN dB) NOTED ON A SEPARATE TYPED SHEET. 21. AFTER STATION CABLE IS TESTED AND DOCUMENTED, ONE PAIR FROM EACH VOICE STATION MUST BE CROSS CONNECTED THROUGH EACH CLOSET BACK TO THE MAIN DISTRIBUTION FRAME. TELEPHONE NUMBER ASSIGNMENTS FOR EACH JACK MUST BE APPROVED BY THE TELECOM STAFF PRIOR TO IMPLEMENTATION. A WRITTEN RECORD OF ALL CROSS CONNECT ASSIGNMENTS WILL BE PROVIDED TO THE OWNER BY THE SCS CONTRACTOR. 22. FIBER CABLES MUST BE SPLICED TOGETHER USING A FUSION SPLICE AND PLACED IN A FIBER SPLICE CASE THAT IS RE-ENTERABLE, FULLY DRESSED AND ENCLOSED TO FIT THE NUMBER AND TYPE OF CABLES TERMINATED. --CONTINUED-- 1. THE LOCATIONS AND ELEVATIONS OF TECHNOLOGY DEVICES SHOWN ON THESE DRAWINGS ARE SCHEMATIC UNLESS ACTUAL DIMENSIONS ARE SHOWN ON THE DRAWINGS. REFER TO THE ARCHITECTURAL PLANS AND OBTAIN THE APPROVAL OF THE ARCHITECT FOR THE ACTUAL LOCATIONS AND ELEVATIONS OF ALL DEVICES. 2. CONTRACTOR MUST ENSURE THAT ALL MOUNTING HEIGHTS COMPLY WITH CURRENT ADA REQUIREMENTS. 3. ABOVE COUNTER DEVICES MUST BE MOUNTED 8" ABOVE COUNTER OR A MAXIMUM OF 44" AFF (TO TOP OF DEVICE). 4. PROVIDE SUPPORTS AND ANCHORING FOR PIPING, CONDUIT, DUCTS, EQUIPMENT, AND OTHER NON-STRUCTURAL ELEMENTS. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 5. FIRESTOPPING: ALL PENETRATIONS THROUGH RATED WALLS AND FLOORS AND CONDUIT/SLEEVE OPENINGS MUST BE SEALED WITH UL LISTED MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAMES, HOT GASSES AND SMOKE WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC FOR APPLICABLE CODES. 6. ALL COMMUNICATIONS CONDUIT, CABLE TRAYS, LADDER RACKS AND EQUIPMENT RACKS MUST BE BONDED TO BUILDING GROUND SYSTEM PER NEC 250 AND ANSI/TIA-607-E.1. 7. LABEL ALL CLOSETS, RACKS, FRAMES, CABINETS, TERMINATION BLOCKS, CABLES, TERMINATIONS, RACEWAYS, ETC. IN ACCORDANCE WITH ANSI/TIA-606-E. 8. ALL COMMUNICATIONS RACEWAYS AND PATHWAYS MUST BE INSTALLED TO MINIMIZE UNNECESSARY CABLE LENGTHS AND MAINTAIN INDUSTRY STANDARD LENGTH LIMITATIONS FOR HORIZONTAL CABLE DISTRIBUTION (E.G CAT.6). BASIC LINK CABLE LENGTH MUST NOT EXCEED 295 FT (90M) FOR UTP CABLE, 150 FT (45M) FOR SERIES-6 COAXIAL CABLE. 9. ALL COMMUNICATIONS CABLE MUST BE PLENUM RATED (CMP), RISER RATED (CMR) AND UNDERGROUND RATED (WATERBLOCK) ACCORDING TO USE AND ENVIRONMENTAL CONDITIONS. 10. PROVIDE PROTECTIVE BUSHINGS ON ALL COMMUNICATIONS CONDUITS AND WHERE CABLING ROUTES THROUGH METAL STUDS. 11. ALL NON-ARMORED FIBER OPTIC CABLE MUST BE INSTALLED IN APPROVED INNERDUCT. 12. ALWAYS INSTALL LOW-VOLTAGE CABLES IN CONDUITS, CABLE TRAYS, WIREWAYS OR OTHER APPROVED CABLE MANAGEMENT DEVICES OR SYSTEMS. NEVER INSTALL CABLES IN SUCH A MANNER THAT THEY ARE SUPPORTED BY CEILING SYSTEMS (CEILING TILE OR GRID, GYPSUM BOARD, LATH & PLASTER), HVAC DUCTS OR PIPES, LIGHTING FIXTURES, ELECTRICAL CONDUITS OR CABLES, PLUMBING/FIRE PROTECTION PIPES, OR ANY OTHER DEVICES NOT INTENDED FOR THE SUPPORT OF LOW-VOLTAGE CABLING. 13. EXPOSED LOW-VOLTAGE CABLES MUST NOT BE PAINTED. ANY PAINTED CABLES MUST BE REMOVED AND REPLACED WITH NEW CABLES. 14. PROVIDE WEATHERPROOF, IN-USE COVER FOR EXTERIOR DATA DEVICES. 15. ALL CABLE TRAY MOUNTING HEIGHTS INDICATED ON FLOOR PLANS ARE TO THE BOTTOM OF CABLE TRAY SUPPORTS. 16. SEISMIC BRACING FOR ALL CABLE TRAYS MUST BE PROVIDED AS REQUIRED BY CODE, LOCAL GOVERNING JURISDICTION AND CABLE TRAY MANUFACTURER SPECIFICATIONS. 17. ALL CABLE TRAY ROUTING THROUGH ELECTRICAL ROOMS MUST BE FULLY ENCLOSED. REFER TO CABLE TRAY DETAILS AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 18. CABLE TRAY AND CABLE ROUTING ARE INTENDED TO SUPPORT ALL TYPES OF TELECOMMUNICATIONS CABLING AS DEFINED IN TIA-569-E. 19. RACEWAYS AND CABLE MUST BE RUN CONCEALED IN FINISHED SPACES UNLESS OTHERWISE INDICATED. 20. ALL TELECOM CABLING IN EXPOSED CEILING SPACES MUST BE IN CONDUIT. ALL CONDUIT IN LOBBIES, VESTIBULES, OPEN OFFICE SPACES, ETC. MUST BE CONCEALED IN PIPE COLUMNS, CURTAIL-WALL MULLIONS AND RECESSED ALONG BEAMS. 21. REUSABLE VELCRO TIES MUST BE USED TO BUNDLE OR MANAGE CABLES. PLASTIC ZIP TIES ARE NOT APPROVED FOR USE. 22. SIZE AND ORIENTATION OF ALL TELECOM PULL-BOXES MUST MEET OR EXCEED THE BICSI TDMM REQUIREMENTS. 23. ALL LOW-VOLTAGE CONDUIT LARGER THAN 2" MUST HAVE A MINIMUM BEND RADIUS OF 10 TIMES THE INSIDE DIAMETER FOR ALL ELBOWS. ALL LOW-VOLTAGE CONDUIT 2" AND SMALLER MUST HAVE A MINIMUM BEND RADIUS OF 6 TIMES OF THE INSIDE DIAMETER FOR ALL ELBOWS. 24. ALL CONDUITS MUST BE INSTALLED WITH PULL-MULE TAPE, 1/2-INCH WIDE, RATED FOR 1250 LBS WITH FOOTAGE MARKS. 25. THE TELECOMMUNICATIONS CONTRACTOR RESPONSIBLE FOR ALL OF THE WORK DESCRIBED IN THESE CONTRACT DRAWINGS AND SPECIFICATIONS MUST BE REFERRED TO THROUGHOUT THESE DOCUMENTS AS THE 'CONTRACTOR'. 26. THE CONTRACTOR MUST ADHERE TO ALL BUILDING RULES AND REGULATIONS. TELECOM GENERAL NOTES 27. THESE COMMUNICATIONS DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE COMMUNICATIONS SPECIFICATION DOCUMENTS, SHOULD THERE BE ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE SPECIFICATIONS. THE CONTRACTOR MUST BRING IT TO THE IMMEDIATE ATTENTION OF THE CONSTRUCTION MANAGER. 28. THE CONTRACTOR MUST BE RESPONSIBLE FOR REPORTING ANY DISCREPANCIES BETWEEN THESE CONTRACT DRAWINGS AND ACTUAL FIELD CONDITIONS, ANY DISCREPANCIES ARE TO BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER. 29. ALL CONDUITS AND SLEEVES DESIGNATED FOR COMMUNICATIONS USE, WHETHER THEY ARE UTILIZED BY THE CONTRACTOR OR NOT, MUST BE FIRE STOPPED. 30. THE CONTRACTOR MUST BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES AND DRAWINGS. FURTHERMORE, THE CONTRACTOR MUST COORDINATE THE SEQUENCE OF WORK WITH THE CONSTRUCTION MANAGER. 31. BACKBOXES, CONDUITS, STUB-UPS, AND CABLE TRAY OUTSIDE THE TELECOM ROOMS MUST BE PROVIDED BY ELECTRICAL CONTRACTOR. 32. CABLE TRAY INSIDE THE TELECOM ROOMS MUST BE PROVIDED BY THE SCS/LV CONTRACTOR. 33. THE ENTIRE CABLE PLANT MUST BE TESTED AS OUTLINED IN THE SPECIFICATIONS. 34. REFER TO THE SPECIFICATIONS FOR ADDITIONAL ABBREVIATIONS AND ACRONYMS. 35. THE CONTRACTOR MUST PROVIDE ALL CABLE, HARDWARE AND EQUIPMENT SHOWN ON THESE DRAWINGS EXCEPT WHERE OTHERWISE NOTED. 36. THE CONTRACT DRAWINGS OF ALL TRADES INCLUDING ARCHITECTURAL, STRUCTURAL, HVAC, ELECTRICAL, PLUMBING, COMM, SECURITY ETC ARE PART OF THIS PACKAGE. THE TELECOMMUNICATIONS CONTRACTOR MUST REVIEW THE DRAWINGS OF ALL OTHER TRADES AND OBTAIN PERTINENT INFORMATION THAT PERTAINS TO THE TELECOM WORK AND IS SHOWN OR INDICATED ON OTHER TRADE DRAWINGS. NO EXTRAS WILL BE PERMITTED DUE TO THE FAILURE OF THE CONTRACTOR TO COMPLY WITH THIS REQUIREMENT. AFTER REVIEW OF ALL DOCUMENTS IF THE CONTRACTOR FEELS SOMETHING IS NOT IN THEIR SCOPE OF WORK, CONTRACTOR MUST TAKE EXCEPTION DURING BID SUBMISSION AND CLEARLY INDICATE THE SCOPE OF WORK FOR WHICH CONTRACTOR IS TAKING THE EXCEPTION. 37. THE CONTRACTOR MUST MAINTAIN A RUNNING UPDATE OF ALL FIELD OR CONTRACT DOCUMENT CHANGES AND UPDATE THEIR "AS BUILT" DRAWINGS AS AN ONGOING PROCESS. 38. ALL EQUIPMENT, CABLING. RACEWAY, ETC, MUST BE GROUNDED IN ACCORDANCE WITH THE SPECIFICATIONS. PROVIDE GROUND CONDUCTORS, GROUND CLAMPS, COMPRESSION TAPS, LUGS, ETC, AS REQUIRED FOR CONNECTION TO THE TELECOMMUNICATIONS GROUNDING AND BONDING SYSTEM (AS REQUIRED). TELECOMMUNICATIONS GROUNDING AND BONDING SYSTEM MUST BE PROVIDED BY DIVISION 26, INCLUDING BUT NOT LIMITED TO: BONDING CONDUCTOR FOR TELECOMMUNICATIONS, TELECOMMUNICATIONS GROUNDING BUSBAR, TELECOMMUNICATIONS BONDING BACKBONE, GROUNDING EQUALIZER AND BONDING CONDUCTORS TO BUILDING STEEL (WHERE APPLICABLE), POWER PANELS (WHERE APPLICABLE) AND CONDUITS. DIVISION 27 CONTRACTOR TO PROVIDE PRIMARY AND SECONDARY BUSBARS FOR TELECOMMUNICATIONS ROOMS, AND COORDINATE WITH DIVISION 26 CONTRACTOR ON THE FINAL LOCATIONS AND BONDING. 39. CONTRACTOR TO COORDINATE WITH SECURITY DRAWINGS, CIVIL AND SITE PLANS FOR CABLING DISTRIBUTION TO SITE PLAN SECURITY CAMERAS, AND OTHER ELEMENTS. 40. USE PULLBOXES WHEREVER THE BENDS IN A CONDUIT RUN EXCEED 180-DEGREES. 41. TELECOMMUNICATION CONTRACTOR MUST COMPLY WITH ZONE 4 SEISMIC REQUIREMENTS FOR ALL EQUIPMENT RACKS, CABLE TRAYS, AND ANY OTHER EQUIPMENT THAT REQUIRES BRACING OR STRUCTURAL SUPPORT, COORDINATE WITH STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO COMMENCEMENT. 42. COORDINATE WITH BMS CONTRACTOR FOR DATA REQUIREMENTS. 43. UNLESS OTHERWISE NOTED, ALL CONDUIT MUST BE MIN. 1" ELECTROMETALLIC TUBING (EMT) AND RUN WITHIN WALLS. 44. ALL ETHERNET NETWORK CABLING IS CATEGORY 6A, CMP. TELECOM GENERAL NOTES CONT. A. THE LOCAL GENERAL CONTRACTOR (GC) IS RESPONSIBLE FOR CONDUIT RACEWAYS, BACK BOXES AND TO PROVIDE AND INSTALL NECESSARY DOOR LOCKING HARDWARE (ELECTRICAL OR OTHER) ELECTRICAL LOCKING HARDWARE TO BE INSTALLED TO THE INSIDE JAMB AND TESTED PRIOR TO SECURITY CONTRACTORS ARRIVAL. ON SITE, SECURITY CONTRACTOR (SC) TO PROVIDE IP CAMERA SYSTEMS, REX DEVICES, CARD READERS. AND INSTALLATION LABOR, INCLUDING FINAL CONNECTIONS. PROGRAMMING AND TESTING. B. SECURITY CABLING SHALL BE COMPLETED BY THE SECURITY CONTRACTOR DESIGNATED VENDOR. THE CABLE SHALL BE INSTALLED FROM THE SECURITY CONTROL PANEL TO THE DOOR THAT IT SERVICES. THERE SHALL BE APPROPRIATE SERVICE LOOP AT EACH END TO REACH THE FIELD DEVICES, THE CONDUIT REQUIREMENTS ARE LISTED BELOW FOR VARIOUS DOOR TYPES. C. THE NETWORK CABLE FOR THE VIDEO CAMERAS IS TO BE TERMINATED AND TESTED PRIOR TO THE INSTALLATION OF THE CAMERAS. THE HORIZONTAL CABLING SHALL BE TERMINATED AT THE TELECOM ROOM TO THE PATCH PANEL AND LABELED. D. THE FIELD END SHALL TERMINATE ON A 8P8C RJ45 OUTLET MOUNTED IN A SINGLE GANG SURFACE MOUNT BLOCK AND BE LABELED IN THE SAME MANNER AS THE PATCH PANEL. A 10' PATCH CORD SHALL BE INSTALLED BY SECURITY CONTRACTOR, AND CONNECTED TO THE NETWORK OUTLET PROVIDED, TO ALLOW FOR THE EXACT PLACEMENT OF THE CAMERA DEVICES. E. DOOR HARDWARE AND WIRING TO THE HINGES IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. SECURITY CONTRACTOR SHALL MAKE THE INTERCONNECTIONS OF THE GENERAL CONTRACTOR PROVIDED LOCKING HARDWARE TO THE ACCESS CONTROL SYSTEM. F. ACCESS CONTROL SYSTEM & EQUIPMENT SHALL BE INSTALLED, UTILIZING OWNER IT NETWORK INFRASTRUCTURE STANDARDS, THE ACCESS CONTROL SYSTEMS SHALL BE INSTALLED IN THE TELECOM ROOM ON A PLYWOOD SHEET UTILIZING A CHASE FOR WIRE MANAGEMENT PER DRAWINGS, THE IP INFORMATION IS TO BE PROVIDED TO THE SECURITY CONTRACTOR BY OWNER. G. VIDEO CAMERAS SHALL BE CONNECTED TO RACK MOUNTED NETWORK SWITCHES IN THE TELECOM ROOM AND PROVIDED BY THE SECURITY CONTRACTOR, NETWORK SWITCHES SHALL BE CONNECTED TO THE VIDEO SURVEILLANCE SYSTEM NETWORK VIDEO SERVER IN THE TELECOMMUNICATIONS ROOM. VIDEO SURVEILLANCE SYSTEM SERVER SHALL BE CONNECTED TO THE OWNER IT NETWORK. H. CONDUIT FOR DOOR CONTACT DEVICES SHALL BE 1" EMT CONDUIT. I. CONDUIT FOR POWER TRANSFER HINGE SHALL BE 1" EMT CONDUIT. J. CONDUIT FOR SECURITY CAMERA SHALL BE 1" EMT CONDUIT. K. THE SYSTEM SHALL UTILIZE CARD READERS, BADGES SHALL BE COORDINATED WITH THE SITE OWNER BY SECURITY CONTRACTOR. ALL ACCESS CONTROL SYSTEM CABLES TO BE PLENUM RATED. L. DOOR DETAILS ARE TYPICAL FOR CONDUIT AND BACK BOX EMT REQUIREMENTS. REFER TO FLOOR PLANS FOR ACTUAL DEVICE LOCATION AT EACH DOOR. M. ALL JUNCTION BOXES SHALL BE MOUNTED ON THE PROTECTED SIDE OF THE DOOR. N. WHERE NO FINISHED CEILING EXISTS, JUNCTION BOXES OVER DOORS SHALL BE PLACED AT LEAST NINE INCHES FROM BOTTOM OF BOX TO TOP OF DOOR AS SPACE PERMITS, BOX COVER TO BE ACCESSIBLE, COORDINATE LOCATION WITH OTHER TRADES. O. RECESSED CONTACTS SHALL BE INSTALLED WITHIN SIX INCHES FROM LATCH SIDE OF DOOR. HANDBOX SHALL BE CENTERED ON CONTACT LOCATION. WIRING FOR DEVICES ON DOUBLE DOORS SHALL BE RUN THROUGH HOLLOW METAL FRAMES. P. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL NECESSARY DOOR LOCKING HARDWARE WHICH IS TO BE INSTALLED TO THE INSIDE JAMB AND TESTED PRIOR TO THE SECURITY CONTRACTOR ARRIVAL. SECURITY CONTRACTOR TO COORDINATE AS REQUIRED. Q. FOR INSTALLATION OF ELECTROMAGNETIC LOCKS, ELECTRIFIED MORTISE LOCKS AND ELECTRICAL STRIKES, FOLLOW MANUFACTURER'S INSTRUCTIONS. SECURITY GENERAL NOTES SECURITY GENERAL NOTES CONT. R. SECURITY DEVICES SHALL BE MOUNTED ON BACKBOXES, AS SHOWN IN INSTALLATION DETAILS. UNLESS OTHERWISE NOTED, CONDUITS, PULL STRINGS, BACKBOXES AND BUSHINGS SHALL BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. S. SECURITY CONTRACTOR SHALL COORDINATE FINAL QUANTITIES, LOCATIONS AND STYLES WITH ELECTRICAL CONTRACTOR AND ARCHITECT. T. PANEL COUNTS AND CONNECTIONS ARE FOR REFERENCE ONLY. CONFIRM ALL COUNTS AND PANEL LAYOUT BASED ON DEVICE COUNTS. U. ALL FIBER IS PROVIDED BY TELECOM CONTRACTOR. V. SECURITY CABLING SHALL BE COMPLETED BY THE SECURITY CONTRACTOR UNLESS OTHERWISE NOTED, CABLE SHALL BE INSTALLED FROM THE TELECOM ROOM TO THE DOOR THAT IT SERVICES WITH AN APPROPRIATE SERVICE LOOP AT EACH END TO REACH FIELD DEVICES. W. NETWORK CABLE FOR VIDEO CAMERAS SHALL BE PROVIDED BY THE TELECOM CONTRACTOR AND IS TO BE TERMINATED AND TESTED PRIOR TO THE INSTALLATION OF CAMERAS, HORIZONTAL CABLING SHALL BE TERMINATED AT THE TELECOM ROOM TO THE PATCH PANEL AND LABELED AS `CAM#' THAT CORRELATES TO THE CAMERA NUMBER IDENTIFIED ON THE SECURITY DRAWINGS. X. THE FIELD END OF NETWORK CABLE FOR VIDEO CAMERAS SHALL TERMINATE TO A SURFACE MOUNTED BOX AND LABELED IN THE SAME MANNER AS THE PATCH PANEL. A 10' PATCH CORD SHALL BE INSTALLED IN THE OUTLET TO ALLOW EXACT PLACEMENT OF THE CAMERAS. Y. SECURITY SYSTEMS AND EQUIPMENT SHALL BE INSTALLED UTILIZING OWNER IT NETWORK INFRASTRUCTURE STANDARDS. IP INFORMATION IS TO BE PROVIDED TO THE SECURITY CONTRACTOR BY THE OWNER AND/OR THE IT STAFF. Z. VIDEO CAMERAS SHALL BE CONNECTED TO SECURITY CONTRACTOR PROVIDED RACK MOUNTED NETWORK SWITCHES IN TELECOM ROOMS. NETWORK SWITCHES SHALL BE CONNECTED TO THE VIDEO SURVEILLANCE SYSTEM SERVER IN THE MDF, VIDEO SURVEILLANCE SYSTEM SERVER SHALL BE CONNECTED TO THE OWNER IT NETWORK. T AV OUTLET PATHWAY SCHEDULE SYMBOL SUBSCRIPT DESCRIPTION PATHWAY BACKBOX TYPE SHARED SERVICES RING MOUNTING HEIGHT NUMBERED NOTESFACEPLATEPATCH CORDS WORK AREA PATCH CORDS TELECOM AREA OUTLET PORT CONFIGURATION HORIZONTAL CABLE SCHEDULE REFER TO DETAIL OUTLET PORT DESCRIPTOR CABLE TYPE TERMINATION AT EQUIPMENT ROOM TERMINATION AT WORK AREA CONNECTOR COLOR 1 2 3 4 5 6 - SEC GENERAL NOTES: A. SOME SYMBOLS MAY NOT BE USED ON PLANS. B. REFER TO PLANS FOR SYMBOL LOCATIONS AND QUANTITIES. C. ROUTE HORIZONTAL CABLING IN CONDUIT AS THE PRIMARY PATHWAY AND J-HOOKS AS THE SECONDARY PATHWAY WHERE APPLICABLE. D. REFER TO THE INSTALLATION DETAILS FOR CONFIGURATION OF PATHWAYS BY OUTLET TYPE. E. PROVIDE A PULL-POINT (JUNCTION BOX) AFTER (2) 90-DEGREE CONDUIT BENDS. LOCATE PULL-POINT IN AN ACCESSIBLE LOCATION. F. PROVIDE A PULL STRING IN CONDUITS. G. LOCATE TELECOM OUTLET ADJACENT AND INLINE WITH ELECTRICAL OUTLET. COORDINATE LOW VOLTAGE OUTLETS WITH ELECTRICAL AND ARCHITECTUAL PLAN(S) FOR TRIM PLATE AND MOUNTING HEIGHTS. H. REFER TO THE LABELING DETAILS FOR CONFIGURATION OF OUTLET FACEPLATES. I. REFER TO THE WAP INSTALLATION DETAILS FOR OUTLET CONFIGURATIONS. J. PROVIDE OUTLET BOX AND CONDUIT IN FIRE-RATED WALLS AND IN ACOUSTICALLY TREATED WALLS IN A MANNER THAT MAINTAINS CLASS, RATING, AND AESTHETICS. K. CONDUIT PATHWAYS TO NOT EXCEED 40% FILL RATIO. L. SCHEDULE SHOWS STANDARD OUTLET INSTALLATION MOUNTING HEIGHT. HEIGHT FOR SPECIFIC OUTLETS MAY DIFFER AND ARE NOTED ON PLANS. NUMBERED NOTES: 1. OWNER FURNISHED, CONTRACTOR INSTALLED (OFCI). 2. OWNER FURNISHED, OWNER INSTALLED (OFOI). 4 TWISTED PAIRS (23 AWG)HORIZONTAL FIELD - RACK MOUNTED MODULAR RACK PANEL MODULAR CAT6 JACK BLUE BLUE CABLE SERVICE TYPES AND TERMINATIONS CONDUCTORS / STRANDS A UTP CAT6A - CFCICAMDATA, SECURITY CAMERA (1) 1" CONDUIT X CEILING HEIGHT, U.O.N.A 1-PORT, SURFACE MOUNT BOXN/A- X - - - -- 2 2-PORT DATA WALL OUTLET (1) 1" CONDUIT X 1-GANG REDUCER 18" AFF, U.O.N.2-PORT, FLUSHA OFOI OFOIA5" x 5" x 2.875"- -- - - - STAINLESS STEEL 1-PORT, FLUSH OFOIW1-PORT PHONE WALL OUTLET (1) 1" CONDUIT X 1-GANG REDUCER 48" AFF, U.O.N.A5" x 5" x 2.875"- -- - - -- CFCIACSACCESS CONTROL SYSTEM (1) 1" CONDUIT X A- X - - - --5" x 5" x 2.875"1-GANG REDUCER 48" AFF, U.O.N.1-PORT, FLUSH BT120-JCD501 DETAIL 3, BT120-JCD503 DETAIL 1 5" x 5" x 2.875" CFCICAMFLUSH MOUNT, SECURITY CAMERA (1) 1" CONDUIT X 120"+ AFF, U.O.N.A 1-PORT, SURFACE MOUNT BOXN/A- -- - - --5" x 5" x 2.875" WAP BT120-JCD501 DETAIL 1, BT120-JCD503 DETAIL 1 BT120-JCD501 DETAIL 2, BT120-JCD503 DETAIL 1 CFCIOUTLET, WIRELESS ACCESS POINT (1) 1" CONDUIT X CEILING HEIGHT, U.O.N.A 1-PORT, SURFACE MOUNT BOXN/A- -- - - --5" x 5" x 2.875" OFOI CFCI OFOI CFCI CFCI BT120-JCD502, BT120-JCD503 DETAIL 1 JACKET COLOR REFER TO SECURITY DETAILS REFER TO SECURITY DETAILS R879.8024 R890.8024 CO CO DET V DETV DETV DETV PTZ DETV PTZ R51.90 R 4 8 . 5 4 R50.00 R20.00 R19.89 R 3 0.0 0 R 3 5 .0 0 R40.00 R 4 0 .0 0 R 4 5 . 0 0 R35.00 R50.00 R35.00 R50.00 R15.00 20 STORAGE SECURITY BUILDING TELECOM ELECTRICAL 1 BT120-JCP002 1 1 N 5.0' edge to edge FO FO CO CO BUS BAY 7 48 48 C O CB1 CB1 CB 1L 6 0 CB1 CB1 CB1 CB1 CB1 STORAGE SECURITY BUILDING TELECOM ELECTRICAL (2) 4" CONDUITS FROM VAULT TO KCM TELECOM ROOM (2) 4" CONDUITS FROM VAULT TO ST TELECOM ROOM N 2 2 2 2 2 W CAM CAM CAM CA M CA M CA M CA M CA M CAM CAM CAM CAM WAP WAPACP W W BMS 2 W2 2 WAP OPERATOR RESTROOM BT120L1204 OPERATOR RESTROOM BT120L1205 OPERATOR RESTROOM BT120L1207 LACTATION ROOM BT120L1202 OPERATOR RESTROOM BT120L1206 JANITOR BT120L1203 2.A 2.G 2.7 2.D 2.32.1 2.J 2.E 2.112.102.92.82.62.52.4 2.B 2.F SECURITY BLDG BT120L1200 TELECOM BT120L1208 ELECTRICAL BT120L1209 STORAGE 1 BT120L1210 SEC STORAGE BT120L1201 CR01-DATA01:01 CR02-DATA01:01-02 CR02-DATA02:03-04 CR02-DATA03:05-06 CR02-DATA04:07-08 CR01-DATA03:03 CR02-DATA05:09-10 CR02-DATA13:21-22 CR01-DATA02:02 CR01-DATA04:04 CR01-DATA05:05 CR02-DATA14:23-24 CR01-DATA06:06 CR02-DATA16:27-28 CR02-DATA17:29-30 CR02-DATA06:11-12 CR02-DATA10:18 CR02-DATA07:13-14 CR01-DATA07:07 CR02-DATA09:17 CR02-DATA15:25-26 CR02-DATA11:19 CR02-DATA08:15-16 CR01-DATA09:09 CR01-DATA08:08 CR01-DATA10:10 CR02-DATA12:20CR01-DATA11:11 CR01-DATA12:12 CR01-DATA13:13 CAM N CAM CAM CAM CA M CA M CA M CA M CA M CAM CAM CAM CAM 2.A 2.G 2.7 2.D 2.32.1 2.J 2.E 2.112.102.92.82.62.52.4 2.B 2.F OPERATOR RESTROOM BT120L1204 OPERATOR RESTROOM BT120L1205 OPERATOR RESTROOM BT120L1207 LACTATION ROOM BT120L1202 OPERATOR RESTROOM BT120L1206 JANITOR BT120L1203 SECURITY BLDG BT120L1200 TELECOM BT120L1208 ELECTRICAL BT120L1209 STORAGE 1 BT120L1210 1 2 1 BT120-JCP261 SEC STORAGE BT120L1201 4 TYP. 9' - 9"9' - 0"7' - 3" 15 ' - 6 " 3 3 BT120-SC-906 BT120-SC-905 BT120-SC-903 BT120-SC-904 5 XBT120-SC-934 BT120-SC-901 BT120-SC-902 BT120-SC-919 BT120-SC-914 BT120-SC-929 BT120-SC-916 BT120-SC-915 BT120-SC-917 BT120-SC-918 BT120-SC-922 BT120-SC-924 BT120-SC-923 BT120-SC-910 BT120-SC-911BT120-SC-913 BT120-SC-912 BT120-SC-921 BT120-SC-932 BT120-SC-935 BT120-SC-908 BT120-SC-909 BT120-SC-907 BT120-SC-925 BT120-SC-926 BT120-SC-933BT120-SC-920 BT120-SC-928 BT120-SC-927 BT120-SC-930 BT120-SC-931 6 6 N CAM CAM CA M AC P W W BM S 2 W 2 2 WA P CAM CAM CA M AC P W W BM S 2 W 2 2 WA P 9 TYP. 6' - 7" 4' - 3" 8' - 5" 3' - 8" 3' - 1" 8' - 0" TELECOM BT120L1208 12 TYP. 4' - 7" 10' - 5" 13TYP. 13 TYP. 14 BT120-SC-981 BT120-SC-991 17 16 17 16 1617 ELEC PNL ELEC PNL BT120-SC-982 BT120-SC-992 10 10 (TYP) (TYP) 2 BT120-JCE262 1 BT120-JCE262 1 BT120-JCE263 REAR 3 REAR 2 4 8 FRONT CR-06 CR-07 CR-08 FRONT 1 7 TYP.TYP.TYP. TYP. ISP RACKS 11 CHAIN LINK FENCE TELECOM BT120L1208 27' - 2" KCM 14' - 8" 12' - 5" SOUND TRANSIT 6' - 10" 3' - 9" 6' - 7" 3' - 9" 5 RE A R FR O N T 4' - 3" 2 BT120-JCE264 1 BT120-JCE264 3' - 11" CR-01 CR-02 CR-03 RE A R FR O N T 3' - 10" 6 TYP. 5 1' - 4" 10" 15 BT120-BMS-01 CR - 0 4 CR - 0 5 ELEC PNL ELEC PNL N CORE FACILITY 28' -2" CORE FACILITY-ROOF 41' -2" TELECOM BT120L1208 SPARE BT120-CR-03 RESERVED FOR SECURITY EQUIPMENT CCTV BT120-CR-01 RESERVED FOR OWNER EQUIPMENT RESERVED FOR OWNER EQUIPMENT LA D D E R R A C K A F F 8' - 2 " 1 6 8 9 10 11 12 13 15 14 16 NETWORK BT120-CR-02 7' - 1 " 3' - 7"4' - 2" 1' - 6"2' - 1" 3' - 7"3' - 5" TYP. 1' - 1 " BT120-UPS-02 BT120-FPP-02 BT120-CPP-03 BT120-SC-01 BT120-UPS-03 BT120-ETH-02 20 21 BT120-FFP-01 BT120-CPP-01 BT120-UPS-05 TYP. 1 1 ? 1 1 3 TYP. 1 1' - 2 " CORE FACILITY 28' -2" CORE FACILITY-ROOF 41' -2" TELECOM BT120L1208 3' - 8"3' - 4"4' - 4" BT120-CR-08 BT120-CR-07 BT120-CR-06 RESERVED FOR KCM EQUIPMENT RESERVED FOR KCM EQUIPMENT SPARE 4 14 5 1 8 2 11 9 10 12 6 15 13 16 TOP OF 2-POST RACK 7' - 0" LADDER RACK AFF 8' - 2" 7 BT120-UPS-04 BT120-FPP-05 BT120-CPP-04 BT120-SC-02 20 22 CORE FACILITY 28' -2" CORE FACILITY-ROOF 41' -2" KING COUNTY METRO RACK BT120-CR-05 SOUND TRANSIT RACK BT120-CR-04 RESERVED FOR SERVICE PROVIDER EQUIPMENT RESERVED FOR SERVICE PROVIDER EQUIPMENT 19 7 10 7' - 0" LADDER RACK AFF 8' - 2" TELECOM BT120L1208 42 6 5 3 8 12 13 14 1' - 2" BT120-FPP-03BT120-FPP-04 9 10 7 1 4 6 11 12 PROVIDE 4' X 8' X 3/4" FIRE RATED AC GRADE PLYWOOD ,PAINTED WITH FIRE-RETARDANT PAINT, LEAVING STAMP EXPOSED. MOUNT PLYWOOD VERTICALLY STARTING 6" A.F.F. ALL PLYWOOD PANELS SHALL BE MOUNTED IN CONTACT WITH EACH OTHER , LEAVING NO GAPS BETWEEN PANELS, BY GC. (TYPICAL). PROVIDE 2-POST RACK, UNIVERSAL, 84-INCH HIGH X 19-INCH WIDE X 45RU, BLACK, MARKED AND NUMBERED RACK UNITS, 1500 LB LOAD CAPACITY. REFER TO RACK ELEVATION FOR ADDITIONAL INFORMATION. SUPPORT FROM STRUCTURE. PROVIDE VERTICAL CABLE MANAGEMENT FRONT AND REAR, 84-INCH HIGH X 6-INCH WIDE X 16.4-INCH DEEP WITH DUAL HINGE METAL DOOR, 82.8-INCH HIGH X 6-INCH WIDE X 16-INCH DEEP. WALL-TO-RUNWAY L-BRACKET. PROVIDE 18" LADDER RACK MOUNTED AT 7'-6" AFF TO BOTTOM OF TRAY UNLESS OTHERWISE NOTED. INCLUDE ASSOCIATED MOUNTING HARDWARE SUPPORT. PROVIDE HOME-RUN 1" CONDUITS FROM TELECOM ROOM TO SECURITY CAMERAS (TYPICAL). 3/8" THREADED ROD, CLAMPED TO BEAM ABOVE BUTT SPLICE KIT, BLACK. STRINGER RADIUS DROP, BLACK. WALL-TO-RUNWAY L-BRACKET. (2) 4" CONDUITS FROM HANDHOLE VAULT TO TELECOM ROOM. PROVIDE 2RU 19-INCH FIBER ENCLOSURE PROVIDE 2RU 19-INCH COPPER PATCH PANEL. KEY NOTES: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 CORE FACILITY 28' -2" CORE FACILITY-ROOF 41' -2" 8 11 1 6 5 7 8 1 14 4 13 2 7 3 10 CORE FACILITY 28' -2" CORE FACILITY-ROOF 41' -2" 19 18 61 ACCESS CONTROL PANELBMS ENCLOSURERESERVED FOR CAT6 EXTENDERS ELECTRICAL PANEL PROVIDE 4' X 8' X 3/4" FIRE RATED AC GRADE PLYWOOD ,PAINTED WITH FIRE-RETARDANT PAINT, LEAVING STAMP EXPOSED. MOUNT PLYWOOD VERTICALLY STARTING 6" A.F.F. ALL PLYWOOD PANELS SHALL BE MOUNTED IN CONTACT WITH EACH OTHER , LEAVING NO GAPS BETWEEN PANELS. (TYPICAL). PROVIDE 2-POST RACK AS REQUIRED; UNIVERSAL, 84-INCH HIGH X 19-INCH WIDE X 45RU, BLACK, MARKED AND NUMBERED RACK UNITS, 1500 LB LOAD CAPACITY. REFER TO RACK ELEVATION FOR ADDITIONAL INFORMATION. ENCLOSED EQUIPMENT CABINET, NOT SHOWN. PROVIDE VERTICAL CABLE MANAGEMENT FRONT AND REAR, 84-INCH HIGH X 6-INCH WIDE X 16.4-INCHDEEP WITH DUAL HINGE METAL DOOR, 82.8-INCH HIGH X 6-INCH WIDE X 16-INCH DEEP. PROVIDE VERTICAL CABLE MANAGEMENT OF FRONT AND REAR, 84-INCH HIGH X 10-INCH WIDE X 16.4-INCH DEEP WITH DUAL HINGED METAL DOOR, 82.8-INCH HIGH X 10.1-INCH WIDE X 16-INCH DEEP. PROVIDE 18" LADDER RACK MOUNTED AT 7'-6" AFF TO BOTTOM OF TRAY. INCLUDE ASSOCIATED MOUNTING HARDWARE SUPPORT. PROVIDE 18-INCH WIDE VERTICAL LADDER RACK, BLACK. 3/8" THREADED ROD, CLAMPED TO BEAM ABOVE. BUTT SPLICE KIT, BLACK. STRINGER RADIUS DROP, BLACK. AS REQUIRED. WALL-TO-RUNWAY L-BRACKET. PROVIDE 6 AWG GROUNDING CABLE BETWEEN EACH LADDER RACK SECTION, PER TIA-607. PROVIDE (2) 4" CONDUITS TO ST VAULT. PROVIDE (2) 4" CONDUITS TO KCM VAULT. KEY NOTES: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A R01 B 2 QUICK PORT 2- PORT FACE PLATE TWO BLUE JACKS LABEL FONT SIZE 4MM BOLD, BLACK ON WHITE 3/8" LABELING TAPE. TELECOMMUNICATIONS ROOM A01 RACK PORT NUMBER ON PANELA02 A03 A04 1 8 BT120L1208 1 81 8 1 8 R01 WALL MOUNT VOICE OUTLET CONSISTING OF ONE CABLE WITH 4 PAIRS TERMINATED INTO INSERT (1) LOCATION. PROVIDE FACEPLATE WITH WALL MOUNT PHONE SUPPORT STUDS. 1 W 21 3 4 5 6 7 8 T R R T T R T R PAIR 2 PAIR 1 PAIR 4 PAIR 3 WHITE/BLUE (TIP) BLUE (RING) WHITE/ORANGE (TIP) ORANGE (RING) WHITE/GREEN (TIP) GREEN (RING) WHITE/BROWN (TIP) BROWN (RING)PAIR 4 PAIR 3 PAIR 2 PAIR 1 MODULAR JACK WIRING DIAGRAM EIA/TIA T568B WIRING LABEL 1 25TYP. OUTLET PORT LOCATION PATCH PANEL POSITION DESIGNATION RACK DESIGNATION A 2 26 3 27 4 28 5 29 6 30 7 31 8 32 9 33 10 34 11 35 12 36 13 37 14 38 15 39 16 40 17 41 18 42 19 43 20 44 21 45 22 46 23 47 24 48 1 NOTE: TERMINAL PATCH PANELS ARE TYPICAL. SIZE, PORT COUNT AND STYLE WILL VARY BY MANUFACTURER. DIAGRAMMATIC ONLY. A R01 QUICK PORT 1- PORT FACE PLATE ONE BLUE JACK LABEL FONT SIZE 4MM BOLD, BLACK ON WHITE 3/8" LABELING TAPE. ACS A. PROVIDE ALL MOUNTING HARDWARE INCLUDING BOLTS ANCHORS AND ATTACHMENTS. B. SUBMIT ANCHOR TYPE FOR SPECIFIC APPLICATION (DRYWALL, CONCRETE, BLOCK WALL ETC.,) FOR STRUCTURAL ENGINEERS APPROVAL. C. DO NOT ANCHOR EQUIPMENT UNTIL AFTER APPROVAL OF ANCHOR TYPE FROM OWNERS REPRESENTATIVE. D. PROVIDE ALL CONDUIT PATHWAYS CONNECTORS, BOXES, COVERS, AND SUPPORTING HARDWARE U.O.N. E. PAINT ALL EXPOSED CONDUIT AND TO MATCH COLOR AND SHEEN OF THE SURFACE AT INSTALLATION LOCATION. F. THE MOUNTING DETAILS ON THIS PAGE ARE DIAGRAMMATIC AND ARE ONLY INTENDED TO CONVEY THE GENERAL SCOPE INVOLVED IN MOUNTING A WIRELESS ACCESS POINT. G. PROVIDE ALL FASTENERS, BRACKETS, ATTACHMENTS, BOLT ANCHORS AND ATTACHMENTS, ETC. PER MANUFACTURER'S REQUIREMENTS. H. PROVIDE ALL CUTTING AND PATCHING OF SURROUNDING SURFACES AS REQUIRED FOR PROPER INSTALLATION. PATCHING SHALL BE OF THE SAME MATERIALS, WORKMANSHIP, AND FINISH, AND ACCURATELY MATCH THE SURROUNDING WORK TO THE SATISFACTION OF THE OWNERS REPRESENTATIVE. I. ALL SUPPORTS, BOLTS, STRAPS, AND FASTENERS INSTALLED ON EXTERIOR OF ANY STRUCTURE SHALL BE CORROSION- RESISTANT. CONNECTORS AND COUPLERS SHALL BE RAIN TIGHT THREADED FITTINGS. J. SUPPORT CABLE ABOVE CEILING USING J-HOOK. CABLE SHALL BE SUPPORTED A MAXIMUM OF EVERY 48-60 INCHES. CABLES ROUTED ABOVE CEILING SPACE SHALL NOT DRAPE ONTO CEILING TILE. CABLE SHALL NOT BE ATTACHED TO WATER PIPES, AIR DUCTS, ELECTRICAL CONDUIT OR CEILING GRID WIRE. PROVIDE J-HOOK. SEE NOTE J ABOVE. PROVIDE (2) CATEGORY 6A CABLES TO NEW MDF OR IDF ROOM AS REQUIRED PER PLANS AND SPECIFICATIONS. IF LENGTH PERMITS PROVIDE A 10' SERVICE COIL IN THE NEAREST PULL BOX OR ACCESSIBLE CEILING SPACE ABOVE THE WIRELESS ACCESS POINT SUPPORTED BY A DEDICATED J-HOOK AND COILED IN A WORKMANSHIP LIKE MANNER. PROVIDE PLENUM RATED VELCRO WRAPS FOR THE MANAGEMENT OF THE SERVICE COIL, TIE-WRAPS ARE NOT PERMITTED. REFER TO PLANS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. PROVIDE 2 PORT FACEPLATE OR SURFACE MOUNTED BOX, AND CATEGORY 6A STATION CONNECTOR, REFER TO PLANS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. PROVIDE (2) CATEGORY 6A PATCH CORDS TO WIRELESS ACCESS POINT. REFER TO PLAN AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. PROVIDE WIRELESS ACCESS POINT (WAP). MOUNTING PLATE SUPPLIED WITH WIRELESS ACCESS POINT. CONTRACTOR TO DOCUMENT AND VERIFY EACH RECEIVED. MOUNTED TO DUAL GANG RING AND 5S/DPDG BOX. PROVIDE TILE BRIDGE FOR ALL ACCESSIBLE CEILING MOUNTED WIRELESS ACCESS POINTS. MOUNT PER MANUFACTURERS INSTALLATION GUIDELINES. CEILING TILE / CEILING GRID SYSTEM (ACCESSIBLE CEILING SPACE) PROVIDE 3/8" MIN. HILTI KB3 WEDGE ANCHOR FOR CONCRETE CONSTRUCTION, MIN. EMBEDMENT PER. MANUFACTURES INSTALLATION GUIDELINES. PROVIDE 1-1/4" CONDUIT TO THE NEAREST WIRE BASKET PATHWAY OR ACCESSIBLE CEILING SPACE. SUPPORTED PER THE NEC, AND GENERAL ELECTRICAL SPECIFICATIONS. REFER TO ELECTRICAL DRAWINGS FOR CONDUIT ROUTING AND ADDITIONAL INFORMATION. PROVIDE 5S/DP MINIMUM OUTLET BOX, WITH DUAL GANG RING SUPPORTED PER THE NEC, AND GENERAL ELECTRICAL SPECIFICATIONS. SUPPORTED BY 3/8" ALL THREAD MIN. 3/8" MIN THREADED ROD. PROVIDE 7/8" SHALLOW SLOTTED CHANNEL UNISTRUT, MUST SPAN FOR 2 POINTS OF ATTACHMENT TO THE UNDERSIDE OF THE WIREBASKET WITH MINIMUM 1/4" MOUNTING SCREWS. VERIFY ATTACHMENT PLAN AND LOCATION WITH OWNERS REPRESENTATIVE PRIOR TO INSTALLATION. SECURITY SCREWS 3/4" KNOCK OUT WAP BRACKET SCREW ANCHOR IN CEILING CABLE LEVELS 2 CAT 6A JACKS 2 EA OF 10' CAT6A PATCH CORDS LABEL ENDS OF PATCH CORDS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 TYP. TYP. TYP. 2 10 4 9 12 11 3 6 5 TYP. TYP. INTERIOR HARD LID CEILING 9 11 3 6 5 4210 TYP. WIRE BASKET 2 4 13 11 3 6 5 TYP. 1 2 3 4 5 8 7 TO MDF/IDF WALL ANGLE SUPPORT KIT, CHATSWORTH #11421-712 #14 x 3" HEX HEAD WITH WASHER SELF TAPPING SMS SCREW INTO METAL BACKING (REFER TO 04/A9.11) OR 1/4" DIA. LAG SCREW WITH 3" MIN. EMBEDMENT INTO WOOD BLOCKING 3/4" PLYWOOD. ATTACH DIRECTLY TO STUD WITH #14 X 3" HEX OR #3/8" SCREWS AT 6" ON CENTER EACH STUD METAL OR WOOD BACKING. 4 2 3 4 1 2 13 1 LADDER RACK LADDER RACK BUTT SPLICE KIT CABLES CONTINUE TO FINAL DESTINATION BEND ANGLE MEASURED FROM VERTICAL HORIZONTAL CONDUIT TO TERMINATE AT PULL BOX, ENCLOSURE, CABLE RUNWAY OR STUB INTO ACCESSIBLE CEILING SPACE BEND RADIUS = MAXIMUM 6 x INTERNAL DIAMETER BEND SHALL BE PROVIDED TO CREATE OPTIMAL CONTINUATION OF CONDUIT AND CABLE TO DESTINATION 1 - INCH CONDUIT VERTICAL CONDUIT TO BACK BOX CONDUIT VERTICAL TO HORIZONTAL BEND SPACE CONSECUTIVE J-HOOKS AS SPECIFIED ELSEWHERE IN DOCUMENTS APPROX. 12 - INCH TO FIRST J-HOOK IN SERIES J-HOOK SUPPORT MAY BE HUNG FROM CEILING AND/OR THE WALL MOUNTED. HORIZONTAL CONDUIT STUB 6 INCH MINIMUM ABOVE ACCESSIBLE CEILING 1 - INCH CONDUIT VERTICAL CONDUIT TO BACK BOX HORIZONTAL CONDUIT STUB ABOVE ACCESSIBLE CEILING INSULATED THROAT BUSHING WALL FLUSH BACK BOX 2 GANG COVER THREADED ROD TO STRUCTURAL CEILING ABOVE ACCESSIBLE CEILING BACK BOX BACK BOX - OPEN CEILING WALL FLUSH BACK BOX 1 GANG 1 GANG MUDRING FLOOR (REF: ARCHITECTURAL) VERTICAL CONDUIT TO BEND 1 - INCH CONDUIT CEILING LEVEL (REF: ARCHITECTURAL) WALL (REF: ARCHITECTURAL) 4 11/16 - INCH SQUARE x 2 1/8 - INCH DEEP BACK BOX STANDARD OUTLET HEIGHT UNLESS OTHERWISE NOTED VERTICAL CONDUIT TO BEND 1-INCH CONDUIT 4 11/16 - INCH SQUARE x 2 1/8 - INCH DEEP BACK BOX 4 - INCH MINIMUM CLEARANCE BETWEEN BOX AND CEILING CEILING GRID (REF: ARCHITECTURAL) PROVIDE SURFACE MOUNT HOUSING THREADED ROD TO STRUCTURAL CEILING VERTICAL CONDUIT TO BEND 1 - INCH CONDUIT 4 11/16 - INCH SQUARE x 2 1/8 - INCH DEEP BACK BOX MUDRING BOTTOM OF BOX MOUNTED AT 10' AFF 2 GANG MUDRING FLOOR (REF: ARCHITECTURAL) VERTICAL CONDUIT TO BEND 1 - INCH CONDUIT CEILING LEVEL (REF: ARCHITECTURAL) WALL (REF: ARCHITECTURAL) 4 11/16 - INCH SQUARE x 2 1/8 - INCH DEEP BACK BOX STANDARD OUTLET HEIGHT UNLESS OTHERWISE NOTED LADDER RACK AUXILIARY FRAMING BAR, SIZE AS REQUIRED CORNER CLAMP BRACKET JUNCTION SPLICE KIT/BRACKET LADDER RACK LADDER RACK RADIUS DROP, CROSS MEMBER 90-DEGREE JUNCTION SPLICE KIT/BRACKET PERPENDICULAR MOUNTING PARALLEL MOUNTING 6" STAND-OFF ELEVATION BRACKETS TYP. 2-POST EQUIPMENT RACK TYP. LADDER RACK TYP. TOP PLATE LADDER RACK THREADED ROD INSTALL 3" FROM JUNCTION SPLICE 90 DEGREE TURN BRACKET LADDER RACK VERTICAL LADDER WALL SIDE ROO M SIDE 3' - 0 " 1' - 0 " RUNWAY END SUPPORT HEX NUTSPLIT LOCK WASHER FENDER WASHER RUNWAY STAND-OFF RUNWAY 1/2”Ø HILTI - Kb-Tz 1/2" WITH 3-1/4" EMBEDMENT PER ICC ESR-1917 # 14 x 3" HEX HEAD WITH WASHER SELF TAPPING SMS SCREW INTO METAL BACKING OR 1/4" DIA. LAG SCREW WITH 3" MIN. EMBEDMENT INTO WOOD BLOCKING BONDING CONDUCTOR TO BLDG STEEL BONDING CONDUCTOR TO 110 BLOCKS BONDING CONDUCTOR TO CONDUIT & OTHER PATHWAYS BONDING CONDUCTOR TO OVERHEAD CABLE SUPPORT BONDING CONDUCTOR TO EQUIPMENT RACKS LABEL: TO EQMT RACKS LABEL: TO BLDG STEEL LABEL: TO (NEXT TR) EXOTHERMIC WELD TBC, INSULATED CONDUCTOR TO TGB LABEL: TO (PREV TR) TBB, INSULATED CONDUCTOR TO TMGB GROUND BUSBAR LABEL: (CURRENT TR) NOTES : LABEL: TO 110 BLOCKS TO CONDUIT TO TRAY/RUNWAY T G B : 2 .1 TO E Q M T R A C K S TO C A B L E T R A Y TO C O N D U I T TO 1 1 0 B L O C K S TO B L D G S T E E L TO ( N E X T T R ) TO ( P R E V T R ) 1. REFER TO ROOM PLANS FOR BUSBAR MOUNTING LOCATION 2. REFER TO GROUNDING RISER DIAGRAM FOR LIST OF EQUIPMENT REQUIRING GROUNDING. ITEMS SHOWN HERE ARE AN EXAMPLE 1. PROVIDE BONDING STRAPS AT ALL RUNWAY SPLICES.WITH SINGLE ATTACHMENT TO TGB (PREVENTS GRND LOOPS). 2. PROVIDE BOND HOME RUN FROM TGB TO ACTIVE EQUIPMENT. 3. CONNECTOR, TYPE #1: TBC-TO-RUNWAY CONNECTOR, SINGLE BARREL LUG. COMPRESSION TYPE CONNECTORS ONLY. 4. CONNECTOR, TYPE #2: TBC TAP CONNECTOR, C-TYPE COMPRESSION TAP. 5. CONNECTOR, TYPE #3: TBC-TO-RACK CONNECTOR, BARREL LUG, 1-BOLT/1-HOLE. 6. FASTENER FOR STRAP SHALL CONSIST OF SELF-TAPPING SCREW WITH LOCK WASHER. FASTENER LENGTH SHALL NOT IMPEDE ON OPPOSITE SIDE OF STRINGER. 7. ABRADE THE FINISH OF THE RACK WHERE THE GROUND WIRES ARE BONDED. CABLE RUNWAY (TYP) C OR H TAPS #6 TBC TO #2 (OPEN END DRAIN) TO TGB. EQ RACKS #6 TO #2. ACTIVE EQUIP RECEIVE DEDICATED #6 TBC TO TGB. SEPARATE ACTIVE AND NON-ACTIVE GROUND BONDING PATHS TO TGB STRAP, WITH FASTENER (TYP) #2 FOR BONDING (C-H TAPS) TO NON ACTIVE EQUIPMENT LADDERS, TRAYS, EQUIPMENT FRAMES. CONNECTOR, TYPE #3 TBC TO TGB TO RM BRANCH PANEL EQUIP GRND BUS- BUILDING STEEL AND TBB IF AVAILABLE #2 #8 EQUIPMENT RACK WALL ANGLE SUPPORT TYPE #1 CONNECTOR BONDING STRAP (TYP) INSTALL FASTENER (SCREW, EXTERNAL TEETH STAR WASHER, HEX NUT) THROUGH STRINGER SPLICE NOTES: 19 1/4-INCH 5/ 8 - I N C H 3/4-INCH 1/4-INCH DIAMETER (TYP)1/4-INCH x 1/2-INCH (TYP) ALL BARS ARE MANUFACTURED FROM 1/4-INCH THICK ELECTROLYTIC TOUGH PITCH COPPER ALLOY 110. ACCOMODATES "A" SPACED TWO HOLE LUGS. 1 1 / 2 - I N C H 5/8 4 5/16 DIA. HOLE 7/16 DIA. HOLE PROVIDE STANDARD BICSI PATTERN CONFIGURATION #350 KCMIL TELECOMMUNICATIONS BONDING CONDUCTOR(TBC) TO MAIN ELECTRICAL GROUND POINT 1/4 1 INSULATOR STAND-OFF WALL MOUNTING BRACKET3 1/2 1 3/4 1 3/4 1/8 20 MOUNT 12-INCHES AFF TO BOTTOM OF PBB. 1/4 5/8 1/8 1 2 20 INSULATOR 1 1/16 #4/0 TELECOMMUNICATIONS BONDING BACKBONE (TBB) TO PRIMARY BONDING BUSBAR (PBB) EXOTHERMIC WELD CONNECTION 5/16 DIA. HOLE 7/16 DIA. HOLE 1 1/8 2 1/2 STAND-OFF WALL MOUNTED BRACKET PROVIDE STANDARD BICSI PATTERN CONFIGURATION MOUNT 12-INCHES AFF TO BOTTOM OF SBB. SLEEVE SLEEVE ELECTRICAL ROOM IDF ROOM TBB TEBC CABLE TRAY ACEG CABLE RUNWAY TGB RACKS (TYP.)TGB ACCESSIBLE CEILING IDF ROOM TBB TBB ELECTRICAL PANEL (TYP) SLEEVE SLEEVE SLEEVE SLEEVE ELECTRICAL SERVICE ENTRANCE SLEEVE BCT TMGB AC GROUNDING ELECTRODE SYSTEM PER DIV 26 TGB RACKS/FRAMES/CABINETS/ ENCLOSURES (TYP.) CABLE RUNWAY CABLE TRAY MDF ROOM TBB IDF ROOM 6 AWG BONDING STRAP / TEBC (TYP) BEP (BUILDING ENTRANCE PROTECTION) A. THIS DETAIL CONVEYS REQUIREMENTS FOR THE CONSTRUCTION OF THE GROUNDING AND BONDING SYSTEM TO PROVIDE A PERMANENT BONDING INFRASTRUCTURE FOR COMMUNICATIONS SYSTEMS, BUT IS GENERIC IN NATURE. SOME ELEMENTS SHOWN MAY NOT BE PRESENT IN THE PROJECT, BUT THOSE ELEMENTS THAT ARE PRESENT SHALL BE GROUNDED AS SHOWN. REFER TO FLOOR PLANS, ELEVATIONS, AND SPECIFICATIONS FOR EXACT LOCATIONS OF GROUNDING AND BONDING ELEMENTS. B. THE TELECOMMUNICATIONS GROUNDING AND BONDING SYSTEM IS BONDED TO THE BUILDING GROUNDING SYSTEM AND IS INTENDED TO PROVIDE A PERMANENT BONDING INFRASTRUCTURE FOR COMMUNICATIONS SYSTEMS. THE PERFORMANCE OF TELECOMMUNICATIONS GROUNDING AND BONDING SYSTEM IS DEPENDANT UPON THE INTEGRITY OF THE BUILDING GROUNDING SYSTEM. THE BUILDING GROUNDING SYSTEM IS COMPRISED OF THE AC ELECTRODE GROUNDING SYSTEM AND THE EQUIPMENT GROUNDING SYSTEM SPECIFIED IN THE DIVISION 26 SPECIFICATION SECTION ELECTRICAL – GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS. C. GROUNDING BACKBONE, ALL CONDUIT SLEEVES AND TMGB / TGB IN EACH TR PROVIDED BY ELECTRICAL CONTRACTOR. D. GROUNDING TO ELEMENTS WITHIN TR PROVIDED BY SCS CONTRACTOR. E. CABLE TRAY AND GROUNDING OF CABLE TRAY BY ELECTRICAL CONTRACTOR. F. CABLE RUNWAY AND GROUNDING OF CABLE RUNWAY BY SCS CONTRACTOR. G. GROUNDING EQUALIZERS (GEs) ARE NOT SHOWN ON THE DETAIL FOR CLARITY AND ARE NOT ALWAYS REQUIRED. REFER TO THE ELECTRICAL CONTRACTOR AND DIVISION 26 SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. H. THE CONDUIT SLEEVE(S) FOR THE ROUTING OF THE GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO THE LATEST EDITION OF THE NEC. THE MINIMUM SIZE SHALL BE 1-INCH. LEGEND INSULATED GROUND WIRE 6 AWG STRANDED, GREEN INSULATED GROUND WIRE OSP COPPER CABLE TBB CONDUCTOR SIZES = = = = = = = 0 TO 20 FEET 20 TO 26 FEET 26 TO 33 FEET 33 TO 44 FEET 44 TO 52 FEET 52 TO 66 FEET GREATER THAN 66 FEET #4 AWG #3 AWG #2 AWG #1 AWG #1/0 AWG #2/0 AWG #3/0 AWG OS P TBB TEBC TEBC ACCESSIBLE CEILING TEBC GENERAL NOTES: TELECOM ROOM (KCM SIDE) FPP04 KCM ISP RACK BT120-CR-05 KCM VAULT BT120-CR-06 BT120-CR-07 BT120-CR-08 FPP05 1 TELECOM ROOM (ST SIDE) ST ISP RACK BT120-CR-04 CCTV RACK BT120-CR-01 BT120-CR-02 BT120-CR-03 FPP02FPP01 3 2 CPP01 9 4 CA M CA M CA M CA M BM S W AC P 2 WA P CAT6 (TYP)SEE CAMERA CABLE SCHEDULE, BT120-JCS006 SEE DATA CABLE SCHEDULE, BT120-JCS006 5 6 7 FPP03 ST VAULT 8 11 12 13 CPP03 1014 LOT 2 CITY OF RENTON LOT LINE ADJUSTMENT LAND USE ACTION NUMBER LUA24-000233 LAND RECORD NUMBER LND30-0438 10' W WL EASEMENT AFN 7408260268 REC NO. 9103110843 15' PUBLIC UTILITY LIMITS OF WATER EASEMENT AFN 9103110843 POWER ESMT TO SEATTLE REC NO. 7408260268 10' WATERLINE EASEMENT BUS BAY 7 BUS BAY 6 BUS BAY 2 BUS BAY 8 BUS BAY 3 BUS BAY 4 48 48 C O CB1 CB1 CB1 CB1 CB1 L 6 0 48 60 CB1 CB1 CB1 CB1L CB1 CB1 60 48 F I XFIX FIX FIX FIX FIX F I X FIX F I X F I X STORAGE SECURITY BUILDING TELECOM ELECTRICAL 360 360 360180 180 180 180 180 180 360 1 BT120-JCP222 2 N JB CR IC P DS MS RX PTZ FIX 360 180 E MP EPB SPB YYYY ## INSTANCE NUMBER YYY EQUIPMENT CODE SPD LOCATION CODE 1.DO NOT SCALE FROM DRAWINGS. THESE DRAWINGS ARE REPRESENTATIVE FOR THE FLOOR PLANS. FIELD VERIFY ALL REQUIRED DIMENSIONS PRIOR TO INSTALLATION. 2. ALL SECURITY EQUIPMENT SHALL BE APPROVED FOR INSTALLATION BY THE CITY REPRESENTATIVE. 3.EXACT LOCATION AND MOUNTING REQUIREMENTS FOR ALL SECURITY EQUIPMENT SHALL BE REVIEWED IN THE FIELD AND COORDINATED WITH THE OWNER. 4. CONTRACTOR SHALL FIRE SEAL ALL CORES AND PENETRATIONS ASSOCIATED WITH THE SECURITY SCOPE OF THE WORK FOR THIS PROJECT. FIRE SEAL SHALL MEET OR EXCEED THE FIRE RATING OF THE MEDIA BEING PENETRATED. 5. ALL CONDUIT, RACEWAYS, PULLBOX AND ASSOCIATED HARDWARE TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE DIVISION 26 SPECIFICATIONS. 6.UNLESS OTHERWISE NOTED ALL SECURITY RELATED ELECTRIC LOCK HARDWARE SHALL BE PROVIDED BY OTHERS. 7. REQUEST TO EXIT DEVICES DO NOT PRECLUDE EXITING FROM THE INTERIOR. ALL EXISTS ARE FREE EGRESS AND SHALL NOT REQUIRE THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT TO EXIT. 8. POWER AND COMMUNICATION WIRING SHALL BE PROVIDED IN SEPARATE CONDUITS AS SHOWN. MAINTAIN 12" SEPARATION BETWEEN POWER AND COMMUNICATION CONDUITS WHEN PARALLEL RUNS EXCEED 10' IN LENGTH. 9. CONTRACTOR TO PROVIDE ALL CABLING, CONNECTIONS AND DEVICES AS SHOWN ON THE DRAWINGS TO PROVIDE A COMPLETE AND OPERATIONAL SYSTEM. 10.CONTRACTOR TO UNIQUELY TAG ALL ADDRESSABLE SECURITY SYSTEM COMMON WITH AN EQUIPMENT IDENTIFICATION TAG, PER THE SPECIFICATIONS AND EQUIPMENT NUMBERING SYSTEM NOMENCLATURE SHOWN ON THIS SHEET. TYPE A: SMARTWIRE MODEL 4461140 (LATEST VERSION), ONE 18 AWG FOUR CONDUCTOR NON-SHIELDED, ONE 22 AWG, SIX CONDUCTOR SHIELDED, ONE 22 AWG, FOUR CONDUCTOR NON-SHIELDED, AND ONE 22 AWG, TWO CONDUCTOR NON-SHIELDED, OR APPROVED EQUAL. TYPE B: WEST PENN MODEL AQC3186 (LATEST VERSION), 18 AWG, SIX CONDUCTOR TWISTED, SHIELDED, WATERBLOCKED CONSTRUCTION OR APPROVED EQUAL. TYPE C: WEST PENN MODEL 224 (LATEST VERSION), 18 AWG, TWO CONDUCTOR, NON-SHIELDED, OR APPROVED EQUAL. TYPE D: WEST PENN MODEL 4246 (BLACK JACKET) (LATEST VERSION), 23 AWG, FOUR PAIR (CAT 6), OR APPROVED EQUAL. TYPE E: MOHAWK MODEL M57622 (BLACK JACKET) (LATEST VERSION), 24 AWG, FOUR PAIR (CAT 6), WATERBLOCKED CONSTRUCTION OR APPROVED EQUAL. TYPE F: WEST PENN MODEL 241 (LATEST VERSION), 22 AWG, FOUR CONDUCTOR, NON-SHIELDED, OR APPROVED EQUAL. TYPE J: WEST PENN MODEL AQC224 (LATEST VERSION), 18 AWG, TWO CONDUCTOR, NON-SHIELDED, WATERBLOCKED CONSTRUCTION OR APPROVED EQUAL. TYPE K: WEST PENN MODEL AQC439 (LATEST VERSION), 22 AWG, FOUR PAIR, SHIELDED, WATERBLOCKED CONSTRUCTION, OR APPROVED EQUAL. TYPE R: FIBER OPTIC CABLING: CORNING FREEDM® CABLES, SINGLE JACKET, MULTIMODE 62.5/125 μm INDOOR/OUTDOOR, 12 FIBERS PER CABLE, MINIMUM, FIBERS TIGHT-BUFFERED, NOT IN GEL-FILLED LOOSE TUBE, 900 μm GRADED-INDEX GLASS, MINIMUM TENSILE STRENGTH; 600 POUNDS. (EXCERPT FROM SECTION 28 05 13 SYMBOL EQUIPMENT NUMBERING SYSTEM SECURITY WIRE AND CABLE - REFERENCE SECURITY LEGEND AND SYMBOLSSECURITY GENERAL NOTES DESCRIPTION ABBREVIATIONS CONDUIT SURFACE MOUNTED CONDUIT UNDERGROUND SECURITY EQUIPMENT ENCLOSURE JUNCTION BOX SIZED PER NEC ELECTRICAL PULLBOX SECURITY PULLBOX JUNCTION BOX SIZED PER DETAIL KEYPAD TAMPER SWITCH GATE OPERATOR PEDESTAL MOTION SENSOR DOOR STATUS CONTACT SURGE PROTECTION DEVICE INTERCOM CARD READER PAN-TILT-ZOOM CAMERA FIXED CAMERA FIXED CAMERA, 360 DEGREE FIXED CAMERA, 180 DEGREE ELECTRIFIED MORTISE LOCK MECHANICAL PANIC REQUEST TO EXIT SWITCH LIMIT SWITCH CONDUIT CONTINUATION CONDUIT STUB GO T K L J 1 FURNISH AND INSTALL (1) 18 AWG 2 CONDUCTOR CABLE. FURNISH AND INSTALL (1) 22 AWG 4 CONDUCTOR CABLE. FURNISH AND INSTALL (1) 22 AWG 6 CONDUCTOR SHIELDED CABLE. FURNISH AND INSTALL WALL MOUNT CARD READER. FURNISH AND INSTALL SURFACE MOUNT DOOR CONTACT. FIELD ROUTE 1 INCH CONDUIT TO SECURITY CONTROL PANEL. FURNISH AND INSTALL REQUEST-TO-EXIT. FURNISH AND INSTALL ROLL-UP DOOR CONTACT. CAMERA TYPE PER DRAWINGS AND SPECIFICATIONS. LENS SIZE AS REQUIRED TO OBTAIN DESIRED VIEW. INCLUDE APPROPRIATE MOUNTING HARDWARE FOR THE LOCATION. INCLUDE TILE BRIDGE AND ELECTRICAL BACKBOX FOR CAMERAS MOUNTED IN ACOUSTICAL TILE. PROVIDE ACCESS CONTROL PANEL TO ACCOMMODATE REQUIRED COMPONENTS. PROVIDED AND INSTALLED BY THE OWNER (SOUND TRANSIT). PROVIDED BY TELECOM CONTRACTOR. REFER TO SHEET BT120-JCE262 FOR DETAILS. PROVIDED BY SECURITY CONTRACTOR. PROVIDE HOME-RUN 1" CONDUITS FROM CARD READERS AND DOOR CONTACT TO ACCESS CONTROL PANEL IN THE TELECOM ROOM (TYPICAL). PROVIDE (1) 6" x 6" x 4" NEMA 1 JUNCTION BOX. MOUNTED ABOVE THE CEILING ON THE SECURE SIDE, AT EACH ACCESS CONTROLLED DOOR (TYPICAL). PROVIDED BY OWNER. INSTALLED BY SECURITY CONTRACTOR. KEY NOTES: 2 3 9 10 11 4 5 6 7 8 ACAMS ACCESS CONTROL & ALARM MONITOR SYSTEM CAM CAMERA C CENTERLINE CR CARD READER CO CONDUIT ONLY CTL CONTROL DS DOOR STATUS CONTACT (E)EXISTING EA.EACH ELC ELECTRIFIED MORTISE LOCK EPB ELECTRICAL PULL BOX EXST EXISTING FBO FURNISHED BY OTHERS FDU FIBER OPTIC DISTRIBUTION UNIT FOC FIBER OPTIC MEDIA CONVERTER FOPP FIBER OPTIC PATCH PANEL GO GATE OPERATOR IC INTERCOM IFP INTELLIGENT FIELD PROCESSOR IN INPUT KPD KEYPAD LMN LATCH MONITOR MP MECHANICAL PANIC ALARM MS MOTION SENSOR (N)NEW OH OPPOSITE HAND OUT OUTPUT PS POWER SUPPLY RX REQUEST-TO-EXIT SECWS SECURITY WORKSTATION TMP TAMPER SWITCH TX TRANSMITTER UON UNLESS OTHERWISE NOTED L 12 13 14 15 16 11.CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING ALL WORK IN STRICT COMPLINCE WITH NATIONAL ELECTRIC CODE (NEC) 70. 12.CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING ALL WORK IN STRICT COMPLINCE WITH AMERICAN DISABILITY ACT (ADA). 13.CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING ALL WORK IN STRICT COMPLINCE WITH INTERNATIONAL BUILDING CODE (IBC). 14.CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING ALL WORK IN STRICT COMPLINCE WITH ST REQUIREMENT MANUAL. DID DOOR INTRUSION DETECTOR SPB SECURITY PULL BOX **REFER TO GEN-GZN006 & GEN-GZN007 FOR ADDITIONAL SYMBOLS AND LEGEND. 17 CR DSFIXFIXFI X FI X FI X FI X FIXFIXFIX CR CRCRCR CRFIXFIXFIXFIXCR CR 2.A 2.G 2.7 2.D 2.32.1 2.J 2.E 2.112.102.92.82.62.52.4 2.B 2.F OPERATOR RESTROOM BT120L1204 OPERATOR RESTROOM BT120L1205 OPERATOR RESTROOM BT120L1207 LACTATION ROOM BT120L1202 OPERATOR RESTROOM BT120L1206 JANITOR BT120L1203 SECURITY BLDG BT120L1200 TELECOM BT120L1208 ELECTRICAL BT120L1209 STORAGE 1 BT120L1210 TELECOMTELECOM SEC STORAGE BT120L1201 BT120-CAM-212 BT120-ACR-01 BT120-ACR-02 BT120-ACR-03 BT120-CAM-213BT120-CAM-211 BT120-CAM-210BT120-ACR-04 BT120-ACP-01 BT120-ACR-05BT120-ACR-06 BT120-ACR-07 BT120-ACR-08 BT120-DID-01 BT120-CAM-201 360 360 360 180 180 180 180 180 180 360 BT120-CAM-203 BT120-CAM-202 BT120-CAM-204 BT120-CAM-205 BT120-CAM-206 BT120-CAM-207 BT120-CAM-208 BT120-CAM-209 BT120-SECWS-03 BT120-SECWS-02 BT120-SECWS-01 BT120L1210B BT120L1210A BT120L1209 BT120L1208B BT120L1208A BT120L1207 BT120L1206 BT120L1205 BT120L1204 BT120L1203 BT120L1202 BT120L1201 BT120L1200B BT120L1200A SECURITY RACK (CCTV) BT120-CR-01 12 12 12 2 2 1. REFER TO DRAWING BT120-JCN051 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES. 2. THIS PLAN DEPICTS THE GENERAL LOCATION OF EQUIPMENT, FIELD DEVICES AND CABLE PATHWAYS. AVOID CONFLICTS WITH EXISTING EQUIPMENT AND COORDINATE FINAL MOUNTING LOCATIONS AND RACEWAY ROUTING WITH OWNER. 3. EQUIPMENT, FIELD DEVICES, CABLE AND CONDUITS SHALL BE LABELED WITH APPROPRIATE TAG NUMBERS AS SHOWN ON THE LEGEND, SPECIFICATIONS AND DETAILS. 4. REFER TO DIV 26 SPECIFICATIONS FOR CONDUIT REQUIREMENTS. 5. DETAILS AS SHOWN ON DWG BT120-JCD551 TO BT120-JCD555 SHALL BE FOLLOWED WHETHER REFERENCED ON THE PLANS OR NOT. 6. ALL FACILITY DOORS HAVE CARD KEY ACCESS EXCEPT FOR OPERATOR RESTROOM AND LACTATION ROOM, WHICH WILL BE KEYED ENTRY BY DRIVERS FROM ST AND KCM. 7. REFER TO DRAWING BT120-JCS051 FOR SECURITY NETWORK RISER DIAGRAM. 8. REFER TO TELECOM DRAWING BT120-JCP-122 FOR CAMERAS CONDUITS PATHWAY, DETAILS AND CABLES SCHEDULE. GENERAL NOTES: CR DS CR CRCRCR CR CR CR 2.A 2.G 2.7 2.D 2.32.1 2.J 2.E 2.112.102.92.82.62.52.4 2.B 2.F OPERATOR RESTROOM BT120L1204 OPERATOR RESTROOM BT120L1205 OPERATOR RESTROOM BT120L1207 LACTATION ROOM BT120L1202 OPERATOR RESTROOM BT120L1206 JANITOR BT120L1203 SECURITY BLDG BT120L1200 TELECOM BT120L1208 ELECTRICAL BT120L1209 STORAGE 1 BT120L1210 TELECOM TELECOM SEC STORAGE BT120L1201 BT120-ACR-01 BT120-ACR-02 BT120-ACR-03 BT120-ACR-04 BT120-ACP-01 BT120-ACR-05BT120-ACR-06 BT120-ACR-07 BT120-ACR-08 BT120-DID-01 SECURITY RACK (CCTV) BT120-SC-20 BT120-CR-01 16 BT120-SC-19 BT120-SC-17 BT120-SC-16 15 BT120-SC-15 BT120-SC-14 BT120-SC-13 16 BT120-SC-12 BT120-SC-18 3 BT120-JCD551 1 BT120-JCD552 1 BT120-JCD552 1 BT120-JCD552 2 BT120-JCD552 1 BT120-JCD552 1 BT120-JCD552 1 BT120-JCD552 1 BT120-JCD552 CONDUIT AND WIRING SCHEDULE CONDUIT TAG EQUIPMENT REMARK COMMENTS FROM TO BT120-SC-12 BT120-ACR-01 BT120-ACP-01 1-1"1-TYPE 'A'ST CARD READER BT120-SC-13 BT120-ACR-02 BT120-ACP-01 1-1" 1-TYPE 'A' ST CARD READER BT120-SC-14 BT120-ACR-03 BT120-ACP-01 1-1" 1-TYPE 'A' ST CARD READER BT120-SC-15 BT120-ACR-04 BT120-ACP-01 1-1" 1-TYPE 'A' ST CARD READER BT120-SC-16 BT120-ACR-05 BT120-ACP-01 1-1" 1-TYPE 'A' ST CARD READER BT120-SC-17 BT120-ACR-06 BT120-ACP-01 1-1" 1-TYPE 'A' ST CARD READER BT120-SC-18 BT120-ACR-07 BT120-ACP-01 1-1" 1-TYPE 'A' ST CARD READER BT120-SC-19 BT120-ACR-08 BT120-ACP-01 1-1" 1-TYPE 'A' ST CARD READER BT120-SC-20 BT120-DID-01 BT120-ACP-01 1-1"1-TYPE 'C'ST DOOR CONTACT CONDUIT SIZE WIRE TYPE 1. REFER TO DRAWING BT120-JCN051 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES. 2. THIS PLAN DEPICTS THE GENERAL LOCATION OF EQUIPMENT, FIELD DEVICES AND CABLE PATHWAYS. AVOID CONFLICTS WITH EXISTING EQUIPMENT AND COORDINATE FINAL MOUNTING LOCATIONS AND RACEWAY ROUTING WITH OWNER. 3. EQUIPMENT, FIELD DEVICES, CABLE AND CONDUITS SHALL BE LABELED WITH APPROPRIATE TAG NUMBERS AS SHOWN ON THE LEGEND, SPECIFICATIONS AND DETAILS. 4. REFER TO DIV 26 SPECIFICATIONS FOR CONDUIT REQUIREMENTS. 5. DETAILS AS SHOWN ON DWG BT120-JCD551 TO BT120-JCD555 SHALL BE FOLLOWED WHETHER REFERENCED ON THE PLANS OR NOT. 6. ALL FACILITY DOORS HAVE CARD KEY ACCESS EXCEPT FOR OPERATOR RESTROOM AND LACTATION ROOM, WHICH WILL BE KEYED ENTRY BY DRIVERS FROM ST AND KCM. 7. REFER TO DRAWING BT120-JCS051 FOR SECURITY NETWORK RISER DIAGRAM. 8. REFER TO TELECOM DRAWING BT120-JCP-122 FOR CAMERAS CONDUITS PATHWAY, DETAILS AND CABLES SCHEDULE. GENERAL NOTES: FIX 360 180 180 180 180 FIX FIX 180 180 360 360 360 SURGE PROTECTION DEVICE SECURITY BUILDING CORE FACILITIES BUILDING TELECOM ROOM SECURITY WORKSTATION NO.1 BT120-SECWS-01 HDMI USB 120V POWER CONNECT TO THE NEAREST CONVENIENCE RECEPTACLE 1" C , ( 1 ) T Y P E ' E ' SECURITY WORKSTATION NO.2 BT120-SECWS-02 1" C , ( 1 ) T Y P E ' E ' SECURITY WORKSTATION NO.3 BT120-SECWS-03 1" C , ( 1 ) T Y P E ' E ' C.F. SECURITY BLDG. INTERIOR BT120-CAM-211 1" C , ( 1 ) T Y P E ' E ' 1" C , ( 1 ) T Y P E ' D ' TO OWNER SECURITY NETWORK 120V UPS POWER CONNECT TO THE RACK POWER DISTRIBUTION UNIT. SECURITY NETWORK SWITCH BT120-ETH-01 (RACK-MOUNTED) SECURITY DIRECTORY SERVER BT120-NAS-01 (RACK-MOUNTED) SECURITY ARCHIVER SERVER BT120-SVR-01 (RACK-MOUNTED) 120V UPS POWER CONNECT TO THE RACK POWER DISTRIBUTION UNIT. POE SURGE PROTECTION DEVICES BT120-ETHSPD-01 (RACK-MOUNTED) 1" C , ( 1 ) T Y P E ' D ' C.F. STORAGE RM SOUTH-EAST PERIMETER BT120-CAM-201 1" C , ( 1 ) T Y P E ' D ' C.F. STORAGE RM ENTRIES BT120-CAM-202 1" C , ( 1 ) T Y P E ' D ' C.F. SOUTH PERIMETER BT120-CAM-203 1" C , ( 1 ) T Y P E ' D ' C.F. SOUTH-WEST PERIMETER BT120-CAM-204 1" C , ( 1 ) T Y P E ' D ' C.F. ELECTRICAL & TELECOM ROOMS ENTRIES BT120-CAM-205 1" C , ( 1 ) T Y P E ' D ' C.F. TELECOM ROOM SOUTH INTERIOR BT120-CAM-206 1" C , ( 1 ) T Y P E ' D ' C.F. TELECOM ROOM NORTH INTERIOR BT120-CAM-207 1" C , ( 1 ) T Y P E ' D ' C.F. OPERATOR RESTROOM ENTRIES BT120-CAM-208 1" C , ( 1 ) T Y P E ' D ' C.F. WEST PERIMETER BT120-CAM-209 1" C , ( 1 ) T Y P E ' D ' C.F. NORTH-EAST PERIMETER BT120-CAM-210 1" C , ( 1 ) T Y P E ' D ' C.F. SECURITY BLDG. NORTH-WEST PERIMETER BT120-CAM-212 1" C , ( 1 ) T Y P E ' D ' C.F. SECURITY BLDG. NORTH-EAST PERIMETER BT120-CAM-213 SECURITY ENTRY BT120-ACR-01 ACCESS CONTROL PANEL (16-DOOR) BT120-ACP-01 (WALL-MOUNTED) SECURITY ENTRY BT120-ACR-02 1" C , ( 1 ) T Y P E ' A ' 1" C , ( 1 ) T Y P E ' A ' SEC STORAGE ENTRY BT120-ACR-03 JANITOR ENTRY BT120-ACR-04 1" C , ( 1 ) T Y P E ' A ' 1" C , ( 1 ) T Y P E ' A ' TELECOM ENTRY BT120-ACR-05 TELECOM ENTRY BT120-ACR-06 1" C , ( 1 ) T Y P E ' A ' 1" C , ( 1 ) T Y P E ' A ' ELECTRICAL ENTRY BT120-ACR-07 1" C , ( 1 ) T Y P E ' A ' 1" C , ( 1 ) T Y P E ' C ' 1" C , ( 1 ) T Y P E ' D ' 120VAC TO ELECTRICAL PANEL 1"C, 2#12, #12G (TYP) STORAGE 1 OVERHEAD BT120-DID-01 1" C , ( 1 ) T Y P E ' A ' HDMI USB 120V POWER CONNECT TO THE NEAREST CONVENIENCE RECEPTACLE HDMI USB 120V POWER CONNECT TO THE NEAREST CONVENIENCE RECEPTACLE CR RXDS EL CR RXDS EL CR DS RX EL CR DS RX EL CR DS RX EL CR DS RX EL CR DS RX EL DS 120V UPS POWER CONNECT TO THE RACK POWER DISTRIBUTION UNIT. STORAGE 1 ENTRY BT120-ACR-08 CR DS RX EL CAT6 COPPER PATCH PANEL BT120-CPP-01 (RACK-MOUNTED) CA T 6 -BT 1 2 0 -L1 2 0 8 -CR 0 1 -DA T A 1 1 : 1 1 CA T 6 -BT 1 2 0 -L1 2 0 8 -CR 0 1 -DA T A 1 3 : 1 3 SURGE PROTECTION DEVICE CA T 6 -BT 1 2 0 -L1 2 0 8 -CR 0 1 -DA T A 1 2 : 1 2 SURGE PROTECTION DEVICE CA T 6 -BT 1 2 0 -L1 2 0 8 -CR 0 1 -DA T A 1 0 : 1 0 SURGE PROTECTION DEVICE CA T 6 -BT 1 2 0 -L1 2 0 8 -CR 0 1 -DA T A 0 9 : 0 9 SURGE PROTECTION DEVICE CA T 6 -BT 1 2 0 -L1 2 0 8 -CR 0 1 -DA T A 0 8 : 0 8 SURGE PROTECTION DEVICE CA T 6 -BT 1 2 0 -L1 2 0 8 -CR 0 1 -DA T A 0 5 : 0 5 SURGE PROTECTION DEVICE CA T 6 -BT 1 2 0 -L1 2 0 8 -CR 0 1 -DA T A 0 4 : 0 4 SURGE PROTECTION DEVICE CA T 6 -BT 1 2 0 -L1 2 0 8 -CR 0 1 -DA T A 0 1 : 0 1 SURGE PROTECTION DEVICE CA T 6 -BT 1 2 0 -L1 2 0 8 -CR 0 1 -DA T A 0 2 : 0 2 SURGE PROTECTION DEVICE CA T 6 -BT 1 2 0 -L1 2 0 8 -CR 0 1 -DA T A 0 3 : 0 3 SURGE PROTECTION DEVICE CA T 6 -BT 1 2 0 -L1 2 0 8 -CR 0 1 -DA T A 0 7 : 0 7 CA T 6 -BT 1 2 0 -L1 2 0 8 -CR 0 1 -DA T A 0 6 : 0 6 1. REFER TO DWG BT120-JCN051 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES. 2. SECURITY VENDOR TO CONFIGURE NEW SECURITY SWITCHES, ACCESS CONTROL PANELS, SECURITY SERVER, AND SECURITY APPLICATIONS TO MAKE A COMPLETE AND FUNCTIONAL SYSTEM. 3. ACCESS CONTROL SERVER IS LOCATED OFFSITE THE FACILITY. GENERAL NOTES: CORE FACILITIES BUILDING TELECOM ROOM 120V UPS POWER CONNECT TO THE RACK POWER DISTRIBUTION UNIT. SECURITY NETWORK SWITCH BT120-ETH-01 (RACK-MOUNTED) POE SURGE PROTECTION DEVICES BT120-ETHSPD-01 (RACK-MOUNTED) CAT6 COPPER PATCH PANEL BT120-CPP-01 (RACK-MOUNTED) CENTER PARKING LOT CES 360 BT120-CAM-09 2" C , ( 1 ) T Y P E ' E ' BEB CHARGING AREA 360 BT120-CAM-10 POE EXT 2" C , ( 1 ) T Y P E ' E ' BEB YARD ROAD 360 BT120-CAM-12 POE EXT 2" C , ( 1 ) T Y P E ' E ' SOUTH PED ENTRANCE 2 360 BT120-CAM-13 2" C , ( 1 ) T Y P E ' E ' SOUTH PED ENTRANCE 1 360 BT120-CAM-14 2" C , ( 1 ) T Y P E ' E ' SOUTHWEST PARKING LOT 360 BT120-CAM-15 POE EXT 2" C , ( 1 ) T Y P E ' E ' LAKE AVE PARKING LOT ENTRANCE 360 BT120-CAM-16 POE EXT 2" C , ( 1 ) T Y P E ' E ' SURGE PROTECTION DEVICE CA T 6 - B T 1 2 0 - L 1 2 0 8 - C R 0 1 - D A T A 1 5 : 1 5 SURGE PROTECTION DEVICE CA T 6 - B T 1 2 0 - L 1 2 0 8 - C R 0 1 - D A T A 1 6 : 1 6 SURGE PROTECTION DEVICE CA T 6 - B T 1 2 0 - L 1 2 0 8 - C R 0 1 - D A T A 1 8 : 1 8 SURGE PROTECTION DEVICE CA T 6 - B T 1 2 0 - L 1 2 0 8 - C R 0 1 - D A T A 1 9 : 1 9 SURGE PROTECTION DEVICE CA T 6 - B T 1 2 0 - L 1 2 0 8 - C R 0 1 - D A T A 2 0 : 2 0 SURGE PROTECTION DEVICE CA T 6 - B T 1 2 0 - L 1 2 0 8 - C R 0 1 - D A T A 2 1 : 2 1 SURGE PROTECTION DEVICE CA T 6 - B T 1 2 0 - L 1 2 0 8 - C R 0 1 - D A T A 2 2 : 2 2 POE EXT PARKING LOT ENTRANCE 360 BT120-CAM-02 SURGE PROTECTION DEVICE 2" C , ( 1 ) T Y P E ' E ' CA T 6 - B T 1 2 0 - L 1 2 0 8 - C R 0 1 - D A T A 1 4 : 1 4 PEDESTRIAN PATH AND S GRADY WAY 360 BT120-CAM-17 SURGE PROTECTION DEVICE 2" C , ( 1 ) T Y P E ' E ' CA T 6 - B T 1 2 0 - L 1 2 0 8 - C R 0 1 - D A T A 2 3 : 2 3 LAKE AVE PARKING LOT ENTRANCE 360 BT120-CAM-18 SURGE PROTECTION DEVICE 2" C , ( 1 ) T Y P E ' E ' CA T 6 - B T 1 2 0 - L 1 2 0 8 - C R 0 1 - D A T A 2 4 : 2 4 PARKING LOT 360 BT120-CAM-04 SURGE PROTECTION DEVICE 2" C , ( 1 ) T Y P E ' E ' CA T 6 - B T 1 2 0 - L 1 2 0 8 - C R 0 1 - D A T A 2 5 : 2 5 POE EXT POE EXT 1. REFER TO DWG BT120-JCN051 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES. 2. SECURITY VENDOR TO CONFIGURE NEW SECURITY SWITCHES, ACCESS CONTROL PANELS, SECURITY SERVER, AND SECURITY APPLICATIONS TO MAKE A COMPLETE AND FUNCTIONAL SYSTEM. 3. ACCESS CONTROL SERVER IS LOCATED OFFSITE THE FACILITY. GENERAL NOTES: CRDS ESRX 6" 42 " A . F . F . 6 6" x 6" x 4" NEMA 1 JUNCTION BOX, MOUNTED ON SECURE SIDE OF DOOR CARD READER FLUSH MOUNTED ON SINGLE GANG BACK-BOX TO LOCAL SECURITY PANEL 3 2 1 7 45 DOOR STATUS SWITCH (SURFACE MOUNT) DOOR STATUS MAGNET (SURFACE MOUNT) 1 REQUEST TO EXIT (RX), HORIZONTAL FLUSH MOUNTED ON BACKBOX FUNCTIONALITY: IN THE NORMAL STATE THE DOOR IS CLOSED, LOCKED ON THE OUTSIDE AND UNLOCKED ON THE INSIDE. NORMAL OPERATION IS BY CARD READER ON THE OUTSIDE AND BY MOTION DETECTOR ON THE INSIDE. THE MOTION DETECTOR WILL SHUNT AN ALARM AND ENABLE AUTHORIZED EXIT. IF THE DOOR IS OPENED WITHOUT THE OPERATION OF THE CARD READER OR MOTION DETECTOR, THE ALARM CONDITION IS MONITORED AT THE SECURITY TERMINAL. 12" CRDS ESRX 6" 42 " A . F . F . 6 CARD READER FLUSH MOUNTED ON SINGLE GANG BACK-BOX DOOR STATUS SWITCH (SURFACE MOUNT) DOOR STATUS SWITCH MAGNET (SURFACE MOUNT) REQUEST TO EXIT (RX), HORIZONTAL FLUSH MOUNTED ON BACKBOX 6" x 6" x 4" NEMA 1 JUNCTION BOX, MOUNTED ON SECURE SIDE OF DOOR TO LOCAL SECURITY PANEL 3 2 1 7 45 1 FUNCTIONALITY: IN THE NORMAL STATE THE DOOR IS CLOSED, LOCKED ON THE OUTSIDE AND UNLOCKED ON THE INSIDE. NORMAL OPERATION IS BY CARD READER ON THE OUTSIDE AND BY MOTION DETECTOR ON THE INSIDE. THE MOTION DETECTOR WILL SHUNT AN ALARM AND ENABLE AUTHORIZED EXIT. IF THE DOOR IS OPENED WITHOUT THE OPERATION OF THE CARD READER OR MOTION DETECTOR, THE ALARM CONDITION IS MONITORED AT THE SECURITY TERMINAL. 12"DS SC H E D U L E D O O R H E I G H T DOUBLE GANG J-BOX 6 SINGLE GANG J-BOX ROLL-UP DOOR TO LOCAL SECURITY PANEL 1 8 DOOR STATUS SWITCH (SURACE MOUNT) DOOR MAGNET (SURFACE MOUNT) FUNCTIONALITY: IN THE NORMAL STATE THE DOOR IS CLOSED, LOCKED FROM THE INSIDE. IF THE DOOR IS OPENED, THE ALARM CONDITION IS MONITORED AT THE SECURITY TERMINAL. 6" 42 " A . F . F . CARD READER FLUSH MOUNTED ON SINGLE GANG BACK-BOX DOOR STATUS SWITCH (SURFACE MOUNT) DOOR STATUS SWITCH MAGNET (SURFACE MOUNT) REQUEST TO EXIT (RX), HORIZONTAL FLUSH MOUNTED ON BACKBOX 6" x 6" x 4" NEMA 1 JUNCTION BOX, MOUNTED ON SECURE SIDE OF DOOR FUNCTIONALITY: IN THE NORMAL STATE THE DOOR IS CLOSED, LOCKED ON THE OUTSIDE AND UNLOCKED ON THE INSIDE. NORMAL OPERATION IS BY CARD READER ON THE OUTSIDE AND BY MOTION DETECTOR ON THE INSIDE. THE MOTION DETECTOR WILL SHUNT AN ALARM AND ENABLE AUTHORIZED EXIT. IF THE DOOR IS OPENED WITHOUT THE OPERATION OF THE CARD READER OR MOTION DETECTOR, THE ALARM CONDITION IS MONITORED AT THE SECURITY TERMINAL. TO LOCAL SECURITY PANEL EH EL DS RX CR 5 4 3 2 7 11 6 12" ELECTRIFIED HINGE PANIC HARDWARE WITH ELECTRIFIED LOCKSET FUNCTIONALITY: IN NORMAL STATE THE DOOR IS CLOSED, LOCKED ON THE OUTSIDE AND UNLOCKED ON THE INSIDE. NORMAL OPERATION IS BY CARD READER ON THE OUTSIDE AND BY MOTION DETECTOR ON THE INSIDE. THE MOTION DETECTOR WILL SHUNT AN ALARM AND ENABLE AUTHORIZED EXIT. IF THE DOOR IS OPENED WITHOUT THE OPERATION OF THE CARD READER, THE ALARM CONDITION IS MONITORED AT THE SECURITY TERMINAL. 42 " A . F . F . CARD READER FLUSH MOUNTED ON SINGLE GANG BACK-BOX APPROX 6" REQUEST TO EXIT (RX) (HORZONTALLY SURFACE MOUNTED) 6" x 6" x 4" NEMA 1 JUNCTION BOX, MOUNTED ON SECURE SIDE OF DOOR DOOR STATUS SWITCH TO LOCAL SECURITY PANEL 6 CR EH EL DS DS RX 3 4 1 1 2 7 1 5 1 6" 6" 12" ELECTRIFIED HINGE PANIC HARDWARE WITH ELECTRIFIED LOCKSET (ACTIVE LEAF) WALL/BEAM MOUNT TO DIGITAL RECORDING EQUIPMENT CEILING MOUNT TO DIGITAL RECORDING EQUIPMENT 9 10 9 FRONT VIEW TO DIGITAL RECORDING EQUIPMENT SIDE VIEW 9 POWER SUPPLY 2" CONDUITS2" CONDUITS GUTTER TO FIELD DEVICES JB120 VAC POWER TAMPER SWITCH (TYP) HINGED DOOR 1" CONDUITS IO SERIAL BOARD ACCESS CONTROLLER DISTRIBUTION MODULE 11 13 BT120-FPP-01 FIBER PATCH PANEL (2RU) 13 BT120-CPP-01 COPPER PATCH PANEL (2RU | 48-PORTS) 14 BT120-ETHSPD-01 POE SURGE PROTECTION DEVICE (1RU | 24-PORTS) 17 BT120-ETH-01 SECURITY NETWORK POE SWITCHES (1RU | 48-PORTS) 14 BT120-SVR-01 SECURITY DIRECTORY SERVER (2RU) 14 BT120-NAS-01 SECURITY ARCHIVER SERVER (2RU) POWER DISTRIBUTION UNIT (1RU) 13BT120-UPS-05 UPS BT120-CR-01 SECURITY RACK 14HORIZONTAL CABLE MANAGER 13 TYP. 14 CABLE TO LOCAL SECURITY PANEL CARD READER CL 42" AFF SINGLE GANG BACK-BOX BUFFER PLATE WALL CONDUIT PIPE STRAP WIRING DEVICE OR ELECTRICAL EQUIPMENT FLOOR OR PLATFORM NOTES 2 AND 3 FOR CONTROL STATIONS MOUNT AT 4'-0"±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