Loading...
HomeMy WebLinkAboutDESIGN-R1 - v2.pdfJOB SITE JOB SITE NEW BORE ~ 72 'CLCLCLB O R E ~ 1 2 0 ' BORE ~ 110' B O R E ~ 7 0 ' ROW = 5 0' EOP ' 3 0' SE 162ND P L 132ND PL SE131ST PL SE132ND PL SE TREE/BUSH TRIMMING REQUIRED 1AAØ - 10521 FROM (V03 317024-167072) TO BE CUT/SPLICED AND RE-ROUTED TO NEW J-BOX (J02) BØ - 10524 FROM (V02 317008-167086) TO BE CUT/SPLICED AND RE-ROUTED TO NEW J-BOX (J02) CB 6' 7'5'34'7'13101 P#2473380330 13105 P#2473380340 13109 P#2473380350 13207 P#2473390360 16203 P#2473390370 16219 P#2473390390 16225 P#2473390400 13200 P#2473390460 16117 P#2473380310 13205 P#2473390410 16121 P#2473380320 OPEN TRENCH ~ 10'BP-2BP-1 B P - 3 BP - 4 BP - 6 OPEN TRENCH ~ 100 BORE ~ 255 ' 16209 P#2473390380 SE FAIRWOOD BLVD BP-5 W.O:101169204-R1POTELCO - PM, Inc.DESIGNED BY MAKE NO CHANGES TO THIS JOB WITHOUT PRIOR APPROVAL Notify Customers and Service Area 48 HRS Prior To Planned Outages ORDER#NOTIF#PROJECT PHASE MAINTENENCE O & M SUPERIOR FAILED SILICONE REMOVAL EXPENSE 11972548 101169204 - 108151859 - 594158016 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. No No No Yes Yes Yes "Flagging Required" "Outages Required" "Locates Required" No No Yes Yes "Joint Trench Coordination Req'd" "Vegetation Management Req'd" UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP R. MILLER 253-355-6930 12/26/25 L. NEELY 253-569-2523 12/26/25 --- R. MILLER 253-355-6930 12/26/25 RW-133189 RENTON O#914569 ROL17 CREW2 13203 SE 164 REPLACE CABLES 10521 & 10523, INSTALL NEW J-BOX 16225 132ND PL SE., RENTON, WA 98058 O#914569 - -101169204-R1 AS NOTED 1 OF 2 KING COUNTY --QCSOKE NW-27-05-23 -- 2305E106 2305E136 2305E106 ROL-17 12/26/25 RMSHOW EXIST UTILITES SEPARATION N/A N/A N/A N/A N/A N/A L. NEELY 253-569-2523 12/26/25 OVERHEAD CIRCUIT MAP: 2305E136 SCALE: 6" = 1 MILE SITE PLAN SCALE: 1:50' VAULT & EQUIPMENT TABLE SITE GRID NUMBER VAULT SIZE & COVER TYPE & SIZE EQUIPMENT IN VAULT PRIMARY BUSHINGS TRANSFORMER ID NUMBERS (COMPANY ID) REMARKS LB DC J01 316936 167135 EXISTING JUNCTION BOX J-BOX BELOW GRADE W/ 3-4 POS. J-BUS EXISTING 2 - J02 NEW 316990 167084 HH 4'-8" X 4'-8" X 3'-6" W/3' AS DOOR MATID:7663900 J-BOX BELOW GRADE W/ 2-4 POS. J-BUS MATID: 7625900 5 - INSTALL NEW 4'-8" x 4'-8" x 3'-6" J-BOX WIRE CREW TO INSTALL GRID NUMBERS V01 316980 167087 EXISTING VAULT 37.5kVA PM XFMR 120/240V EXISTING -- V02 317008 167086 EXISTING VAULT 37.5kVA PM XFMR 120/240V EXISTING --NOT SHOWN, NORTH OF V01 V03 317024 167072 EXISTING VAULT 50kVA PM XFMR 120/240V EXISTING --NOT SHOWN, NORTH OF V01 TOTALS :7 - ABANDONED / REMOVE / REPLACED CABLE SCHEDULE CABLE NO. SAP EQUIP LOCATIONS CABLE (LF) EST EXISTING CABLE MFG. NAME EXISTING CABLE MFG. DATE ABANDONED CABLE LEFT IN PLACE ABANDON CIRCUITRYFROMTO 10521 10651964 J01 V01 710 YES NO 10523 10651978 J01 V01 760 YES NO TOTAL CIRCUIT FEET 1,470' VICINITY MAP SITE SPECIFIC NOTES V01 -INSTALL NEW PRIMARY ELBOW (1) (6041.1000 - ELB10J) J02 (NEW J-BOX) -INSTALL NEW J-BOX 15 KV, 5 X 5 X 4 (6055.1010 JBOX1AS), LOCATION MARKED -INSTALL 2-4 POS J-BUSES (MID: 7625900) -INSTALL (5) 1/0 ELBOWS (6041.1000 ELB10J) -INSTALL NEW GRID NUMBER (316990-167084) J01 - J02 (NEW) -INSTALL 1-4" CONDUIT 710'± (L_____') -PULL NEW 2-1Ø PRIMARY CABLES APROX 725'± (L_____') -INSTALL NEW CABLE TAGS (EJY184 & EJY185) V01 - J02 (NEW) -INSTALL 1-2" CONDUIT 10'± (L_____') -PULL NEW 1Ø PRIMARY JUMPER APROX 15'± (L_____') -INSTALL CABLE TAG (EJY186) J01 TO V01 -CUT AND ABANDON IN PLACE CABLE 10521 APROX 710± (L_____') -CUT AND ABANDON IN PLACE CABLE 10523 APROX 800± (L_____') V01 - V03 (317024-167072) LOCATED NORTH -CUT & RE-ROUTE EXISTING CABLE 10521 INTO NEW J-BOX J02 V01 - V02 (317008-167086) LOCATED NORTH -CUT & RE-ROUTE EXISTING CABLE 10524 INTO NEW J-BOX J02 VOLUME OF DISTURBANCE TABLE TYPE DESCRIPTION PROPERTY CLASSIFCATION SIZE (FT)REM CU YD (APPX)GRAVEL FILL CU YD (APPX) COMMON SURFACE TYPES REMARKS BP-1 BORE PIT ROW 2 X 8 X 3 1.8 1.8 ASPHALT BP-2 BORE PIT ROW 2 X 8 X 3 1.8 1.8 ASPHALT BP-3 BORE PIT ROW 2 X 8 X 3 1.8 1.8 ASPHALT BP-4 BORE PIT ROW 2 X 8 X 3 1.8 1.8 ASPHALT BP-5 BORE PIT ROW 2 X 8 X 3 1.8 1.8 ASPHALT BP-6 BORE PIT ROW 2 X 8 X 3 1.8 1.8 ASPHALT OPEN TRENCH TRENCH PVT PROP 1 X 10 X 3 0.2 0.2 ASPHALT OPEN TRENCH TRENCH ROW 1 X 100 X 3 0.2 0.2 ASPHALT 1-PH J-BOX VAULT EXC PVT PROP 8X8X4.33 10.3 7.1 GRASS TOTAL PVT PROP CU YDS (APPX)10.6 7.3 TOTAL ROW CU YDS (APPX)3.8 3.8 TOTAL CU YDS (APPX)14.3 11.1 14' A - 132ND PL SE, SE 162ND PL & 131ST PL SE (LOOKING NORTH) NOT TO SCALE SOUTHBOUND LANE NORTHBOUND LANE EOPCL 50'ROW SIDEWALK 14'1'5' KING COUNTY ROW LEGEND STREET CENTER LINECL RIGHT OF WAY BORE PATH BORE PIT BORE PIT"BP"- PROPERTY LINE EASEMENT POT HOLE OPEN TRENCH →···→→···→DRAINAGE SLOPE BUSHESTREE POT HOLE"PH"- EOP ROW SIDEWALK 1'5' CREW NOTE: POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS. NEW 21 lbs 33 lbs NEW 1-2" EJY186 - BØ JUMPER EJY184 - AØ EJY185 - BØ NEW 1-4"270 lbs 289 lbs AØ - 58378 BØ - 58379 CØ - 58380 EXISTING TO REMAIN AØ - 58089 BØ - 58088 EXISTING TO REMAIN CØ - 58086 EXISTING TO REMAIN AØ - 10521 FROM (V03 317024-167072) TO BE CUT/SPLICED AND RE-ROUTED TO NEW J-BOX (J02) BØ - 10524 FROM (V02 317008-167086) TO BE CUT/SPLICED AND RE-ROUTED TO NEW J-BOX (J02) S E 1 6 2 N D P L 132ND PL SESE FAIRWOOD BLVD131ST PL SE132ND PL SE AØ58378 BØ58379 CØ58380 EXISTING TO REMAIN CØ - 58086 EXISTING TO REMAIN AØ58089 BØ58088 EXISTING TO REMAIN AØ - 10521 BØ - 10523 ABANDON IN PLACE AØ - 10521 FROM (V03 317024-167072) TO BE CUT/SPLICED AND RE-ROUTED TO NEW J-BOX (J02) BØ - 10524 FROM (V02 317008-167086) TO BE CUT/SPLICED AND RE-ROUTED TO NEW J-BOX (J02) JUMPER EJY186 - BØ NEW EJY184 - AØ EJY185 - BØ NEW AØ58089 BØ58088 EXISTING TO REMAIN AØ - 58378 BØ - 58379 CØ - 58380 EXISTING TO REMAIN CØ - 58086 EXISTING TO REMAIN AØ - 10521 FROM (V03 317024-167072) TO BE CUT/SPLICED AND RE-ROUTED TO NEW J-BOX (J02) BØ - 10524 FROM (V02 317008-167086) TO BE CUT/SPLICED AND RE-ROUTED TO NEW J-BOX (J02)W.O:101169204POTELCO - PM, Inc.DESIGNED BY ONE-LINE CONDUIT DIAGRAM SCALE: 1:100' PRIMARY CABLE & CONDUIT TABLE (FOREMAN TO COMPLETE) LOCATION CONDUIT PRIMARY CABLE QTY OF LUBE (gal.)REMARKS FROM TO SIZE (in)QTY DESIGN LENGTH (ft) ACTUAL LENGTH (ft) TYPE BENDS PULL (lbs) PULL REV (lbs) SIZE DESIGN LENGTH (ft) ACTUAL LENGTH (ft) CABLE NUMBERS MANUFACTURING INFORMATION For Feeder Cable Only Check applicable box DB120 HDPE SCH 80 90 45 22 11 A B C MANUFACTURER COMPOUND YEAR TAPE CN #4/0 NEU DESIGN AS BUILT J01 J02 4 1 710 270 289 1/0 AL JKT 725 EJY184 -4.4 J01 J02 ---270 289 1/0 AL JKT 725 EJY185 -- V01 J02 2 1 10 1/0 AL JKT 15 -EJY186 0.1 TOTAL 4"710'TOTAL 1Ø 1,450'4.4 TOTAL 2"10'TOTAL 1Ø 15'TOTAL LUBE 4.5 PRE - UG MAP: #2305E106,109 SCALE: 1:100' POST - UG MAP: #2305E106,109 SCALE: 1:100' UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP R. MILLER 253-355-6930 12/26/25 L. NEELY 253-569-2523 12/26/25 --- R. MILLER 253-355-6930 12/26/25 RW-133189 RENTON O#914569 ROL17 CREW2 13203 SE 164 REPLACE CABLES 10521 & 10523, INSTALL NEW J-BOX 16225 132ND PL SE., RENTON, WA 98058 O#914569 - -101169204-R1 AS NOTED 2 OF 2 KING COUNTY --QCSOKE NW-27-05-23 -- 2305E106 2305E136 2305E106 ROL-17 12/26/25 RMSHOW EXIST UTILITES SEPARATION N/A N/A N/A N/A N/A N/A L. NEELY 253-569-2523 12/26/25