Loading...
HomeMy WebLinkAboutMFP25006514.pdfNote: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. PUBLIC WORKS DEPARTMENT Page 1 of 6 | Published: 2/25/2025 Transportation Systems Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 2/25/2025 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK AND FOR TRAFFIC SIGNAL WORK WITHIN 150 FEET OF THE INTERSECTION AT LEAST FIFTEEN (15) WORKING DAYS BEFORE THE DATE OF WORK. FOR PURPOSES OF THIS APPLICATION, WORKING DAYS ARE DEFINED AS MONDAY THRU FRIDAY, AND EXCLUDING CITY HOLIDAYS. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a Traffic Control Plan (TCP) and obtain City's approval of that plan when construction, repair, or maintenance work is to be conducted within the City's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. All TCPs must conform to all attached requirements. Failure to do so may be subject to resubmittal. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” 4. Resubmittal may be required for TCPs that are incomplete and do not display proper requirements as described in the guidelines. Additional review time may be needed. By signing, I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge and have read all the requirements and guidelines on this application. Applicant’s Signature Date Applicant’s Name (Print) Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: ___________ Description of Work: 24 Hour Emergency Contact Name & Phone: Approval By: ______________________________________________ Date:____________________ PW/Transportation or CED/Development Engineering Division Potelco, Inc 6905 S 228th St Kent, WA 98466 Please See Attached 4108 SE 2ND PL 101186789 2/23/2026 TBD Katie Zimmerman 12/18/25 Page 2 of 6 | Published: 2/25/2025 This Page Intentionally Left Blank Page 3 of 6 | Published: 2/25/2025 APPLICANT AGREES TO ALL THE FOLLOWING REQUIREMENTS: GENERAL • Applicant is responsible for compliance with all traffic regulations of the City of Renton (City) and the State of Washington, including codes and regulations not described in this application. • Work Zone Traffic Control shall be in accordance with Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to Washington State Department of Transportation (WSDOT) traffic control plans. • Any lane or street closures not in conformance with the approved Traffic Control Plan (TCP) and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved TCPs including claims arising from towing of private vehicles and the acts of Applicant’s agents and employees. • Applicant must comply with all conditions of the application. • The City shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this application, Applicant is responsible to pay for legal counsel chosen by the City to defend against same. • No more than one TCP shall be in use at any given time for a single project. If multiple TCPs are submitted for review and approval at the same time, the TCPs shall be clearly labeled as separate plans and include construction phasing and sequencing. • Previously approved TCPs cannot be combined into a new TCP without review and approval by the City. • Expired TCP is not valid and shall not be used. Applicant shall resubmit the expired TCP for approval with the updated date and time and/or any changes to TCP. • Applicant must have the approved TCP prior to commencing the work. • Approved TCP must be at the work site during work hours. • Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. • At signalized intersections, vehicle detection shall always remain operational, unless approved in this TCP and notified Transportation Signal Maintenance prior to commencing work. If damage occurs to existing vehicle detection that is to remain, it is Applicant’s responsibility to replace with video vehicle detection equipment that meets current City’s standards at Applicant’s expense. • When not in use, temporary traffic control devices shall be removed or covered immediately. It is the Applicant’s responsible to cover any temporary traffic control devices when not applicable for the construction activities. Similarly, when work is suspended for short periods of time, traffic control devices that are no longer necessary shall be removed or covered. If deemed abandoned, City crews will remove and may store them at the City’s maintenance shop (3555 NE 2nd Street) for up to sixty (60) days. The City is not responsible for any private property from City assets and identifying the property owner. • Applicant is responsible to maintain existing pedestrian accessible routes during work and non-work hours. At intersections, the work on pedestrian facilities shall be limited to one (1) corner at a time, with the least possible inconvenience or delay to pedestrians. Pedestrian pushbuttons shall remain accessible at all times, unless approved pedestrian accessible detour(s) are provided. Accessibility to existing or temporary Page 4 of 6 | Published: 2/25/2025 pedestrian pushbuttons shall not be impaired. Deficiencies caused by Applicant’s operations shall be repaired at Applicant’s expense. • Applicant shall provide complete assistance and accommodation from a dedicated pedestrian escort to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. • Driveway and alley access shall be maintained at all times, also see RMC Chapters 9 and 10 for Street Closure and Street Excavation for details. Applicant is responsible for coordinating with the property owners and/or residents prior to commencement of the work. • Pavement excavation shall be limited to a maximum of one travel lane at a time unless otherwise approved. • Accessibility for emergency vehicles shall be maintained at all times. PUBLIC OUTREACH • Applicant must notify Transportation Signal Maintenance (425-430-7423) and City inspector (425-430- 7203) at least twenty-four (24) hours before commencing work (lane shift/closure or near a signal) affecting the vehicle detection. • Applicant shall notify emergency services (253-852-2121) twenty-four (24) hours before any street closures or lane closures. • Applicant shall call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five (5) working days (excluding weekends and holidays) prior to starting any work. • Applicant shall coordinate with King County Metro Transit Construction Information Center (206-477-1140 or construction.coord@kingcounty.gov) for any construction or installation activities affecting transit operations or facilities. Notification information and guidelines can be found at: https://kingcounty.gov/en/dept/metro/about/contractor-resources/transit-system-impacts. WORKING DAYS AND TIMES • Normal working days are Monday through Friday. Work on holidays, weekends or at night shall not occur without City’s approval. For work times between 10:00 p.m. and 7:00 a.m., see Night Work section below for details. • Work time begins when any street or travel lane is fully or partially closed. This includes set up and removal within the traveled way. • If the City determines the closure hours adversely affect traffic during the work, the City may require to adjust or reduce the working hours accordingly. Reduced work hours may be required by the City to minimize traffic impacts for any work located near a school during pick-up and drop-off times or on an arterial street. (See WSDOT Functional Classification Map: https://www.wsdot.wa.gov/data/tools/geoportal/?config=FunctionalClass) • Applicant may request the City for consideration of extended or modified working hours. Such request must be approved by the City before changing hours of work. CLOSURES • All closure hours and days are subject to local permit and ordinance conditions (such as noise ordinances). More information can be found on https://www.rentonwa.gov/City-Services/Permit-Center. Total street closure lasting more than twenty-four (24) hours is subject to City Council authorization per Section 9-9 of the Renton Municipal Code (RMC). • Road closure notice – Applicant must install Portable Changeable Message Sign (PCMS) boards no less than five (5) working days in advance of effective date and time, not including holidays, at location(s) as identified in the TCP. Other methods of displaying the messages shall be approved by the City. Page 5 of 6 | Published: 2/25/2025 • Road closure notice messages must include at least the following:  ROAD WILL BE CLOSED  MONTH/DAY – MONTH/DAY  _AM - _PM • Road and/or sidewalk closure must be evaluated by the City with respect to both the necessity as well as the impact of the closure to the public. Applicant shall submit detour plans for road closures to accommodate both motorized and non-motorized users, including accessible pedestrian route(s). Road closures shall require additional temporary traffic control including advance notification, approach and detour signage. • Applicant is responsible to temporarily remove the flags and install bags over the flag holders for any work requiring the temporary closure of a crosswalk equipped with pedestrian flags. Applicant shall ensure the bags remain intact and shall replace damaged bags as needed or determined necessary by the City of Renton inspector. For any misplaced or lost flags, Applicant is responsible to replace at Applicant’s own expense. Upon restoration of the crosswalk, Applicant shall remove the bags and return all flags to the holders. Inventory of pedestrian flags must be submitted to the City inspector and reported to City of Renton Transportation Signal Maintenance (425-430-7423) prior to removal. UNIFORMED POLICE OFFICERS (UPO) / FLAGGERS • Any construction activities within one hundred and fifty (150) feet of a signalized intersection shall require Uniformed Police Officer(s) (UPO) at the traffic signal, unless otherwise approved in this TCP and evaluated by City Transportation for the impacts of traffic signal operations and safety. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • For TCPs that require the presence of UPO to manage vehicular traffic and pedestrians at signalized intersections, Applicant shall coordinate with Transportation Signal Maintenance (425-430-7423) at least twenty-four (24) hours in advance for any signal that will be placed in red flashing mode. Applicant shall notify Transportation Signal Maintenance when the intersection is back to the normal traffic signal operations. TEMPORARY TRAFFIC SIGNALS OR TRAFFIC SIGNAL MODIFICATION • Temporary traffic signal programming or modification requires a minimum fifteen (15) working days for each traffic signal controller to be programmed and tested by City Transportation staff before starting the work. The Start Date on this TCP shall reflect the time for temporary traffic signal programming or modification. TEMPORARY NO-PARKING • Applicant must post notice of date(s) and time(s) of Temporary No Parking Zone with signs at every hundred (100) feet at least seventy-two (72) hours in advance of effective date and time. • Applicant is responsible to show on the TCP the limits of Temporary No Parking Zone, identifying barricade locations for vacate parking or curb lane usage. The cover sheet of this approved TCP form must be attached to each Temporary No Parking Sign on the project site. • Two travel lanes (one for each approach) must be open at all times on arterial streets unless approved in this TCP. NIGHT WORK • Between the hours of 10 p.m. and 7 a.m., approved Noise Variance shall be required (See Section RMC 8-7- 8) for night work. Process may take up to twelve (12) weeks. More information can be found at https://www.rentonwa.gov/City-Services/Permit-Center/Land-Use-Development/Noise-Variance. • City may require night work for TCPs that have severe traffic impacts on arterial streets. Page 6 of 6 | Published: 2/25/2025 • Night work shall always be required if two lanes of traffic (One for each approach) cannot be maintained on an arterial street. • Night work shall be required if an evaluation of existing traffic volumes and patterns finds that any TCP will functionally reduce an arterial or high-volume collector street to only one lane of traffic. • The following configurations may require night work:  Work at traffic signals that requires shifting one direction of traffic into a left turn pocket where a high volume of left turns occur.  Work at traffic signals that requires shifting two directions of traffic into left turn pockets.  Work at traffic signals that requires shifting high-volume left-turn movement into a through lane on a single approach to the intersection.  Work at signals that requires shifting left-turning traffic into a through lane on multiple approaches to the intersection. • If City’s initial TCP review finds that night work is required, a pre-construction meeting is mandatory to confirm the extents of the work required, the duration of work, anticipated noise levels, and any potential alternatives to mitigate the impact of night work to adjacent residents prior to review and approval of the TCP. TRAFFIC CONTROL PLAN (TCP) FORMAT • TCP must be site and project specific. The TCP shall clearly indicate all existing transportation facilities impacted by work including roads, bike lanes, sidewalks, transit stops, and driveways. Typical drawings, taper tables and MUTCD illustrations, by themselves, are insufficient. • Each construction phase shall be provided with appropriate work zone traffic control. The impacts of utility relocation, traffic delays, detours and capacity restrictions must be considered and addressed. A suitable sequence of construction activities must be discussed with City Staff prior to fully developing TCPs based on the complexity of a project. • TCPs shall be clearly labeled as separate plans to identify the construction sequencing during each phase when more than one TCP layout is submitted. • TCP must be submitted with an electronic copy of TCP layout(s), on 11” X 17” paper size PDF format, which consist of:  Map(s) showing the location of the project and work area.  All fonts shall be legible and a minimum 10-point font size.  All symbols of viewing or printing shall be clear and contrasting.  All streets shall be labeled, and layout must include a north arrow and scale.  Must show channelizing devices, signing, flagger locations, barricades, PCMS boards, etc.  Show locations where the standard traffic control plans are applied. EXISTING GATE SE 2ND PL 17 17 U N I O N A V E S E EVERGREEN DR 18 18 U N I O N A V E S E 18 18 U N I O N A V E S E 18 18 16 16 J03 STOP STOP STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA W2 0 - 1 ROAD WORK AHEAD W2 0 - 4 ONE LANE ROAD AHEAD X' ≥ X' ≥ X'≥ W2 0 - 7 A W2 0 - 1 ROAD WORK AHEAD W2 0 - 4 ONE LANE ROAD AHEAD X' ≥ X' ≥ X'≥ W2 0 - 7 A W20-1 RO A D WO R K AH E A D S/W CLOSEDR9 - 9 DETOURM4 - 9 B S/W CLOSEDR9 - 9 DETOUR M4 - 9 B W20-7A CREW WILL USE ADA COMPLIANT RAMPS FOR PEDESTRIAN DIVERSION N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Project Address: Page PSE PUGET SOUND ENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 1 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 EXISTING GATE SE 2ND PL 17 17 U N I O N A V E S E EVERGREEN DR 18 18 U N I O N A V E S E 18 18 U N I O N A V E S E 18 18 16 16 STOP STOP STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA W2 0 - 1 ROAD WORK AHEAD W2 0 - 4 ONE LANE ROAD AHEAD X' ≥ X' ≥ X'≥ W2 0 - 7 A W2 0 - 1 ROAD WORK AHEAD W2 0 - 4 ONE LANE ROAD AHEAD X' ≥ X' ≥ X'≥ W2 0 - 7 A W20-7A W20-1 RO A D WO R K AH E A D BE PR E P A R E D TO ST O P W3-4 X'≥X'≥X'≥ W20-7A THE CREW SHALL CEASE WORK AND ESCORT PEDESTRIANS AROUND/THRU WORK AREA RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE Project Address: Page PSE PUGET SOUND ENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 2 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 VASHON AV E S E SE 1 S T P L EXISTING GATE VA S H O N A V E S E SE 2ND PL VA S H O N A V E S E 17 17 SE 2ND PL 17 17 UN I O N A V E S E EVERGREEN DR 18 18 UN I O N A V E S E 18 18 16 16 13 13 16 16 16 16 16 16 J01 STOP STOP STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA W2 0 - 1 ROAD WORK AHEAD STOP W20-1 RO A D WO R K AH E A D W20-4 ON E L A N E RO A D AH E A D X'≥X'≥X'≥ W20-7A W2 0 - 1 ROAD WORK AHEAD W2 0 - 4 ONE LANE ROAD AHEAD X' ≥ X' ≥ X'≥ W2 0 - 7 A W20-1 RO A D WO R K AH E A D W20-4 ON E L A N E RO A D AH E A D X'≥X'≥X'≥ W20-7A W2 0 - 1 RO A D WO R K AH E A D BE PR E P A R E D TO ST O P W3- 4 X'≥ X'≥ X'≥ W2 0 - 7 A S/ W CL O S E D R9-9 DE T O U R M4-9B S/W CLOSEDR9 - 9 DETOUR M4 - 9 B W2 0 - 1 ROAD WORK AHEAD W20-4 ON E L A N E RO A D AH E A D X'≥X'≥ W20-7A USE MAXIMUM AVAILABLE SPACE FOR SIGNS RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Project Address: Page PSE PUGET SOUNDENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 3 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 VASHON A V E S E SE 1 S T P L VA S H O N A V E S E SE 1ST PL 16 16 S E 1 S T P L SE 2ND PL V A S H O N A V E S E 17 17 SE 2ND PL 17 17 13 13 16 16 16 16 16 16 16 16 STOP STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA STOP W20-1 RO A D WO R K AH E A D BE PR E P A R E D TO ST O P W3-4 X'≥X'≥X'≥ W20-7A W2 0 - 1 ROAD WORK AHEAD W2 0 - 4 ONE LANE ROAD AHEAD X' ≥ X' ≥ X'≥ W2 0 - 7 A W20-1 RO A D WO R K AH E A D W20-4 ON E L A N E RO A D AH E A D X'≥X'≥X'≥ W20-7A W2 0 - 1 ROAD WORK AHEAD W2 0 - 4 ONE LANE ROAD AHEAD X' ≥ X' ≥ X'≥ W2 0 - 7 A S/W CLOSEDR9 - 9 DETOURM4 - 9 B S/W CL O S E D R9-9 DE T O U R M4- 9 B RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE W20-1 RO A D WO R K AH E A D BE PR E P A R E D TO ST O P W3-4 X'≥X'≥X'≥ W20-7A CREW WILL USE ADA COMPLIANT RAMPS FOR PEDESTRIAN DIVERSION Project Address: Page PSE PUGET SOUND ENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 4 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 VASHON A V E S E SE 1 S T P L VA S H O N A V E S E SE 1ST PL 16 16 S E 1 S T P L SE 2ND PL V A S H O N A V E S E 17 17 SE 2ND PL 17 17 13 13 16 16 16 16 16 16 16 16 V01 STOP STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA STOP W20-1 RO A D WO R K AH E A D W2 0 - 1 ROAD WORK AHEAD BE PREPARED TO STOP W3 - 4 X' ≥ X' ≥ X'≥ W2 0 - 7 A W20-1 RO A D WO R K AH E A D BE PR E P A R E D TO ST O P W3-4 X'≥X'≥X'≥ W20-7A S/W CL O S E D R9- 9 DE T O U R M4- 9 B S/W CLOSEDR9 - 9 DETOUR M4 - 9 B RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE W20-1 RO A D WO R K AH E A D W20-1 RO A D WO R K AH E A D W20-4 ON E L A N E RO A D AH E A D X'≥X'≥X'≥ W20-7A USE MAXIMUM AVAILABLE SPACE FOR SIGNS Project Address: Page PSE PUGET SOUND ENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 5 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 VASHON A V E S E SE 1 S T P L SE 1ST PL 16 16 S E 1 S T P L 16 16 16 16 16 16 16 16 V02 STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA STOP W20-1 RO A D WO R K AH E A D S/W CLOSEDR9 - 9 DETOURM4 - 9 B S/ W CL O S E D R9-9 DE T O U R M4-9B RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE CREW WILL USE ADA COMPLIANT RAMPS FOR PEDESTRIAN DIVERSION W20-1 RO A D WO R K AH E A D W20-4 ON E L A N E RO A D AH E A D X'≥X'≥X'≥ W20-7A W20 - 4 ON E L A N E RO A D AH E A D X'≥ X'≥ W20 - 7 A W2 0 - 1 ROAD WORK AHEAD Project Address: Page PSE PUGET SOUND ENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 6 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 16 16 VA S H O N A V E S E SE 1ST PL VASHON AV E S E SE 1 S T P L VASHON AVE SE 16 16 SE 1ST PL 16 16 SE 1 S T P L 16 16 16 16 1 6 16 16 16 16 16 STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA STOP S/ W CL O S E D R9-9 DE T O U R M4-9B S/ W CL O S E D R9-9 DE T O U R M4-9B RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE CREW WILL USE ADA COMPLIANT RAMPS FOR PEDESTRIAN DIVERSION W20-1 RO A D WO R K AH E A D W20-4 ON E L A N E RO A D AH E A D X'≥X'≥X'≥ W20-7A W20-4 ON E L A N E RO A D AH E A D X'≥X'≥ W20-7A W2 0 - 1 ROAD WORK AHEAD X'≥ Project Address: Page PSE PUGET SOUNDENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 7 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 16 16 VA S H O N A V E S E SE 1ST PL VASHON AV E S E VASHON AVE SE BR E M E R T O N A V E S E BR E M E R T O N P L S E 16 16 SE 1ST PL 16 16 SE 1 S T P L 16 16 16 16 16 16 16 16 16 16 STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA STOP S/ W CL O S E D R9-9 CR O S S H E R E S/ W C L O S E D AH E A D R9-11 S/ W CL O S E D R9-9 CR O S S H E R E S/ W C L O S E D AH E A D R9-11 RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE W2 0 - 1 ROA D WOR K AHE A D BEPRE P A R E D TO STO P W3 - 4 X'≥ X'≥ X'≥ W2 0 - 7 A W2 0 - 1 ROAD WORK AHEAD BE PR E P A R E D TO ST O P W3-4 X' ≥ X'≥X'≥ W20-7A W2 0 - 1 ROAD WORK AHEAD W20-1 RO A D WO R K AH E A D W20-4 ON E L A N E RO A D AH E A D X'≥X'≥X'≥ W20-7A USE MAXIMUM AVAILABLE SPACE FOR SIGNS Project Address: Page PSE PUGET SOUNDENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 8 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 16 16 VA S H O N A V E S E SE 1ST PL VASHON AV E S E VASHON AVE SE BR E M E R T O N A V E S E BR E M E R T O N P L S E 16 16 SE 1ST PL 16 16 SE 1 S T P L 16 16 16 16 16 16 16 16 16 16 V03 STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA STOP S/ W CL O S E D R9-9 CR O S S H E R E S/ W C L O S E D AH E A D R9-11 S/ W CL O S E D R9-9 CRO S S H E R E S/W C L O S E D AHE A D R9 - 1 1 RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE W2 0 - 1 ROA D WOR K AHE A D BEPRE P A R E D TO STO P W3 - 4 X'≥ X'≥ X'≥ W2 0 - 7 A W2 0 - 1 ROAD WORK AHEAD BE PR E P A R E D TO ST O P W3-4 X' ≥ X'≥X'≥ W20-7A W2 0 - 1 ROAD WORK AHEAD W20-1 RO A D WO R K AH E A D W20-4 ON E L A N E RO A D AH E A D X'≥X'≥X'≥ W20-7A USE MAXIMUM AVAILABLE SPACE FOR SIGNS Project Address: Page PSE PUGET SOUNDENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 9 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 16 16 VA S H O N A V E S E SE 1ST PL VASHON AV E S E VASHON AVE SE BR E M E R T O N A V E S E BR E M E R T O N P L S E 16 16 SE 1ST PL 16 16 SE 1 S T P L 16 16 16 16 16 16 16 16 16 16 STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA STOP S/ W CL O S E D R9-9 DE T O U R M4-9B S/W CLO S E D R9 - 9 DET O U R M4 - 9 B RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE W20-1 RO A D WO R K AH E A D W20-4 ON E L A N E RO A D AH E A D X'≥X'≥X'≥ W20-7A W2 0 - 1 ROAD WORK AHEAD W20-4 ON E L A N E RO A D AH E A D X' ≥ X'≥X'≥ W20-7A W2 0 - 1 ROAD WORK AHEAD STOP W20-1 RO A D WO R K AH E A D W20-4 ON E L A N E RO A D AH E A D X'≥X'≥X'≥ W20-7A USE MAXIMUM AVAILABLE SPACE FOR SIGNS CREW WILL USE ADA COMPLIANT RAMPS FOR PEDESTRIAN DIVERSION J04 Project Address: Page PSE PUGET SOUNDENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 10 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 16 16 VA S H O N A V E S E SE 1ST PL VASHON AVE SE B R E M E R T O N A V E S E B R E M E R T O N P L S E B R E M E R T O N P L S E N E 1 S T P L 16 16 16 16 16 16 16 16 16 16 STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA S/W CLOSED R9 - 9 CRO S S H E R E S/W C L O S E D AHE A D R9 - 1 1 C R O S S H E R E S / W C L O S E D R9-11 A RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE STOP STOP STOP W2 0 - 1 ROAD WORK AHEAD W2 0 - 4 ONE LANE ROAD AHEAD X' ≥ X' ≥ X'≥ W2 0 - 7 A W2 0 - 1 ROAD WORK AHEAD W2 0 - 4 ONE LANE ROAD AHEAD X' ≥ X' ≥ X'≥ W2 0 - 7 A W 2 0 - 1 RO A D WO R K AH E A D BE PR E P A R E D TO STO P W 3 - 4 X'≥ X'≥ X'≥ W 2 0 - 7 A W20-1 RO A D WO R K AH E A D BE PR E P A R E D TO ST O P W3-4 X'≥X'≥X'≥ W20-7A W2 0 - 1 ROA D WOR K AHE A D W2 0 - 4 ONE L A N E ROA D AHEA D X'≥ X'≥ X'≥ W2 0 - 7 A C/W CL O S E D R9-3 DE T O U R M4-9B Project Address: Page PSE PUGET SOUND ENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 11 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 V04 16 16 VA S H O N A V E S E SE 1ST PL VASHON AVE SE B R E M E R T O N A V E S E B R E M E R T O N P L S E B R E M E R T O N P L S E N E 1 S T P L 16 16 16 16 16 16 16 16 16 16 STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA CR O S S H E R E S/ W C L O S E D R9-11A C R O S S H E R E S/ W C L O S E D R9-1 1 A RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE STOP STOP STOP W2 0 - 1 ROAD WORK AHEAD W2 0 - 4 ONE LANE ROAD AHEAD X' ≥ X' ≥ X'≥ W2 0 - 7 A W2 0 - 1 ROAD WORK AHEAD X' ≥ W 2 0 - 1 RO A D WO R K AH E A D W20-1 RO A D WO R K AH E A D BE PR E P A R E D TO ST O P W3-4 X'≥X'≥X'≥ W20-7A W2 0 - 1 ROA D WOR K AHE A D W2 0 - 4 ONE L A N E ROAD AHEA D X'≥ X'≥ X'≥ W2 0 - 7 A BE PREPARED TO STOP W3 - 4 X' ≥ X'≥ W2 0 - 7 A USE MAXIMUM AVAILABLE SPACE FOR SIGNS Project Address: Page PSE PUGET SOUND ENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 12 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 J02 16 16 VA S H O N A V E S E SE 1ST PL B R E M E R T O N A V E S E B R E M E R T O N P L S E B R E M E R T O N P L S E N E 1 S T P L 16 16 16 16 16 16 16 16 16 16 16 16 FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA S/W CLOSEDR9 - 9 RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE STOP STOP W2 0 - 1 ROAD WORK AHEAD BE PREPARED TO STOP W3 - 4 X' ≥ X' ≥ X'≥ W2 0 - 7 A W2 0 - 1 ROAD WORK AHEAD W2 0 - 4 ONE LANE ROAD AHEAD X' ≥ X' ≥ X'≥ W2 0 - 7 A W 2 0 - 1 RO A D WO R K AH E A D BE PR E P A R E D TO STO P W 3 - 4 X'≥ X'≥ X'≥ W 2 0 - 7 A W20-1 RO A D WO R K AH E A D X'≥ W2 0 - 1 ROA D WOR K AHE A D X'≥ STOP STOP VASHON AVE SE BE PR E P A R E D TO ST O P W3-4 X'≥X'≥ W20-7A DETOURM4 - 9 B S/W CLO S E D R9 - 9 DET O U R M4 - 9 B CREW WILL USE ADA COMPLIANT RAMPS FOR PEDESTRIAN DIVERSION Project Address: Page PSE PUGET SOUND ENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 13 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 16 16 VA S H O N A V E S E SE 1ST PL VASHON AV E S E VASHON AVE SE BR E M E R T O N A V E S E BR E M E R T O N P L S E 16 16 SE 1ST PL 16 16 SE 1 S T P L 16 16 16 16 16 16 16 16 16 16 STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA S / W C L O S E D R9-9 C R O S S H E R E S / W C L O S E D A H E A D R9-11 CROS S H E R E S/W C L O S E D R9 - 1 1 A RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE W20-1 RO A D WO R K AH E A D W20-4 ON E L A N E RO A D AH E A D X'≥X'≥X'≥ W20-7A STOP STOP W20-1 RO A D WO R K AH E A D BE PR E P A R E D TO ST O P W3-4 X'≥X'≥X'≥ W20-7A W2 0 - 1 ROAD WORK AHEAD W20-4 ON E L A N E RO A D AH E A D X' ≥ X'≥X'≥ W20-7A W2 0 - 1 ROAD WORK AHEAD USE MAXIMUM AVAILABLE SPACE FOR SIGNS PLACE AT THE INTERSECTION WITH SE 1ST PL Project Address: Page PSE PUGET SOUNDENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 14 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 16 16 VA S H O N A V E S E SE 1ST PL VASHON AV E S E VASHON AVE SE BR E M E R T O N A V E S E BR E M E R T O N P L S E 16 16 SE 1ST PL 16 16 SE 1 S T P L 16 16 16 16 16 16 16 16 16 16 V05 STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA S/ W CL O S E D R9-9 C R O S S H E R E S / W C L O S E D A H E A D R9-11 C R O S S H E R E S/ W C L O S E D A H E A D R9- 1 1 RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE W20-1 RO A D WO R K AH E A D W20-4 ON E L A N E RO A D AH E A D X'≥X'≥X'≥ W20-7A STOP W20-1 RO A D WO R K AH E A D W2 0 - 4 ONE L A N E ROA D AHEA D X' ≥ X'≥ X'≥ W2 0 - 7 A W20-1 RO A D WO R K AH E A D USE MAXIMUM AVAILABLE SPACE FOR SIGNS PLACE AT THE INTERSECTION WITH SE 1ST PL S/ W CL O S E D R9 - 9 Project Address: Page PSE PUGET SOUNDENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 15 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 16 16 VA S H O N A V E S E SE 1ST PL VASHON AV E S E SE 1 S T P L VASHON AVE SE 16 16 SE 1ST PL 16 16 SE 1 S T P L 16 16 16 16 1 6 1 6 16 16 16 16 STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA S/ W CL O S E D R9-9 RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE W20 - 1 RO A D WO R K AH E A D W2 0 - 1 ROAD WORK AHEAD W20-4 ON E L A N E RO A D AH E A D X'≥X'≥ X'≥ W20-7A STOP W20-1 RO A D WO R K AH E A D W2 0 - 4 ONE L A N E ROAD AHEA D X'≥ X'≥ W2 0 - 7 A W20-1 R O A D W O R K A H E A D USE MAXIMUM AVAILABLE SPACE FOR SIGNS DE T O U R M4-9B S / W C L O S E D R9-9 D E T O U R M4-9 B CREW WILL USE ADA COMPLIANT RAMPS FOR PEDESTRIAN DIVERSION Project Address: Page PSE PUGET SOUNDENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 16 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 16 16 VA S H O N A V E S E VASHON AV E S E SE 1 S T P L SE 1 S T P L SE 2ND PL VA S H O N A V E S E 17 17 SE 2ND PL 17 17 13 13 16 16 16 16 16 16 16 16 V06 STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA S / W C L O S E D R9-9 RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE STOP DE T O U R M4-9B S/ W CL O S E D R9-9 DE T O U R M4-9B CREW WILL USE ADA COMPLIANT RAMPS FOR PEDESTRIAN DIVERSION STOP W2 0 - 1 ROA D WOR K AHE A D W2 0 - 4 ONE L A N E ROA D AHEA D X'≥ X'≥ X'≥ W2 0 - 7 A W20-1 RO A D WO R K AH E A D W2 0 - 1 ROAD WORK AHEAD W2 0 - 4 ONE LANE ROAD AHEAD X' ≥ X' ≥ X'≥ W2 0 - 7 A W20-1 RO A D WO R K AH E A D USE MAXIMUM AVAILABLE SPACE FOR SIGNS W2 0 - 1 ROAD WORK AHEAD BE PREPARED TO STOP W3 - 4 X' ≥ X' ≥ X'≥ W2 0 - 7 A Project Address: Page PSE PUGET SOUNDENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 17 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 16 16 VA S H O N A V E S E VASHON AV E S E SE 1 S T P L SE 1 S T P L SE 2ND PL VA S H O N A V E S E 17 17 SE 2ND PL 17 17 13 13 16 16 16 16 16 16 16 16 STOP FR O M TO TO W A W A Y A R E A PH O N E 6 8 4 - 5 4 4 4 NA M E O F F I R M X X X - X X X - X X X X NO P A R K I N G PLACE SIGNS BOTH SIDES OF WORK AREA S/W CL O S E D R9-9 RESIDENT(S) WILL BE INFORMED OF TEMPORARY DRIVEWAY CLOSURE STOP DE T O U R M4- 9 B S/ W CL O S E D R9-9 DE T O U R M4-9B CREW WILL USE ADA COMPLIANT RAMPS FOR PEDESTRIAN DIVERSION STOP W2 0 - 1 ROA D WOR K AHE A D W2 0 - 4 ONE L A N E ROAD AHEA D X'≥ X'≥ X'≥ W2 0 - 7 A W20-1 RO A D WO R K AH E A D W2 0 - 1 ROAD WORK AHEAD W2 0 - 4 ONE LANE ROAD AHEAD X' ≥ X' ≥ X'≥ W2 0 - 7 A W20-1 RO A D WO R K AH E A D USE MAXIMUM AVAILABLE SPACE FOR SIGNS W2 0 - 1 ROAD WORK AHEAD W2 0 - 4 ONE LANE ROAD AHEAD X' ≥ X' ≥ X'≥ W2 0 - 7 A Project Address: Page PSE PUGET SOUNDENERGY Designer: Job # REV Flaviana Nunes 425-424-7386 flaviana.rodriguesnunes@pse.com 18 OF 184108 SE 2nd Pl, Renton 0 12022684 11/19/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRON ARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP WORK PIT MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Flaviana R. Nunes Card No. 013414 Card Exp. 11/2026 flaviana.rodriguesnunes@pse.com (425)424-7386 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 OVERHEAD APPARATUS "When performing planned work on a pole with an existing transformer or device, the Service Provider will change out bolted connectors to pressed connectors". Use unit 1-3A to charge time. If you are working on a pole with the pole ground connected with a hot tap, replace it. If the transformer has split bolts on the secondary neutral or services, replace them. If the primary neutral is connected with a hot tap, replace it. If the transformer bank has a 2-bolt connector on the neutral bus, replace it. PSE GENERAL SPECIFICATIONS General - All work is to be completed per PSE Standards & Practices. Copies of all PSE Standards are available upon request. - Work sites shall be kept clear of debris and all construction materials, equipment and packing shall be removed daily. - Return all unused and removed poles, transformers and hardware to PSE, storeroom. All copper shall be coiled and returned the day it is removed from the poles. Remove all unused pins and insulators. - Return all Street lights, area lights and floodlights. - All fault indicators will be maintained in their current location on the 1/0 cables upon completion of the job. If it is noted to remove any of the indicators they shall be returned to local PSE first response department for re-issue. Preconstruction - Notify appropriate city, County or DOT authorities 48 to 72 hours, or as required by permitting agency, in advance of starting work in Right-of-way involving a Permit. - All system switching shall be approved by System Operations (425-882-4652) a minimum of 48 hours in advance. - Notify customers of all outages 48 hours in advance. Work Drawings & Documents - Field design changes shall be approved by Project Manager or Engineer. - Mark all field changes, equipment ID numbers and Underground cable information in red on Foreman's copy of work sketch. - Return one Foreman's copy of work sketch to Project Manager at completion of job. - When permits are required, a copy shall be available on work site at all times. Safety - Refer to PSE standards 6275.3000 and 6275.6000 for system ground requirements. - Refer to PSE standards 6275.9050 for personal protective grounding requirements. - Refer to PSE standards 6275.9150 for vehicle grounding and barricading requirements. - Proper line clearances shall be taken at the beginning, and released at the end, of each work day, or as otherwise instructed by the System Operator. Traffic /Pedestrian control notes - Utilize flagging and other vehicle traffic control as necessary and in conformance with local traffic regulations. -The uniform code of traffic control shall be adhered to at all times.. -Provide signs, barricades, and traffic control in conformance with local permit regulations. -Provide route for pedestrians when working on or near sidewalks. -Maintain traffic flow as required by permitting agency. NOTE: Completely rebuild terminations. EXCEPTION: DO NOT REPLACE CUTOUTS UNLESS THEY ARE THE OLDER "BOX TYPE" OR 50 AMP "TRIP LINK" TYPE CUTOUT. REPLACE J-BOXES IF REQUIRED. UTILIZE FEED-THRU T.U.T.s AND REMOVE J-BOXES IF POSSIBLE. REPLACE ALL TRANSFORMER JUMPERS WITH NEW 1/0 JACKETED CABLE. UNDERGROUND CONSTRUCTION Additional notes to standards. -Erosion control must be placed before construction starts. Silt bags must be installed in downstream catch basins. Existing Utilities: Hand excavate (pothole) all marked utility crossings to verify exact location and depth at point of crossing. Protect underground utilities during excavation. Use hand excavation methods if necessary to avoid damage to existing utilities. Fabricate and install adequate temporary structures to support and protect underground utilities while exposed during construction. Maintain 6" minimum clearance at crossings between existing utilities and new duct installations. Transition trench or tunnel profile gradually as required at crossings. Maintain 24" minimum separation between new trench or tunnel and parallel existing utilities or as required by the permit agency. Excavation - Trenching outside of the Right-of-way shall be of sufficient depth to provide a minimum of 36" of cover for primary conductors and 24" of cover for secondary conductors. - Road crossings and all trenches within the Right-of-way shall be of sufficient depth to provide a minimum of 36" of cover for all conductors or as required by the permitting Agency. - No rocks larger than 8" shall be included in backfill. - Back fill in road crossings and within the Right-of-way shall be compacted to 95% density or as required by the permitting Agency. - Restore all excavated areas to original condition. Vaults & Hand holes - Refer to PSE standard 6775.0040 "Vault and Hand hole Installation" - Vaults shall be placed level and 2" above final grade in landscaped areas and flush with final grade when placed in hard surface areas. - A minimum 6" bed of 5/8" crushed rock shall be placed under all vaults. - All conduit entrances shall be grouted. Conductors & Conduit - Refer to PSE standard 6800.6000 "PVC Conduit Installation". - Unless splices are called for, or otherwise noted or approved, conduit risers shall be plumbed directly to road crossing conduits. - Install insulating caps on all unused primary bushings. - Civil crew to install Conduit plug on each end until new cable to be installed. - All "spare" conduits shall be capped at each end. Surface Restoration Restore ground surface to original contour and original condition or better. Restore asphalt and concrete in accordance with requirements of local permitting agency. Cold patch or plate trench when necessary. Leave area in its original state or better at the end of construction. SCOPE OF WORK The general scope of this project is to remediate primary cables within the project area by the most economic means possible using replacement, or abandonment. The project involves replacing existing electrical cables in new conduit. Project type : Planned Project location : 4114 SE 1ST PL, RENTON, WA 98059 Number of Cables : 11 Cable Footage Estimated : 4,693' Cable Numbers Injected : 0 Cable Numbers Repaired : 0 Cable Numbers Abandoned : 0 Cable Numbers Replaced : 30054, 30053, 30055, 30056, 30057, 30058, 30059, 30060, 30043, 30044, 30045 Trench Footage Estimated : 4,693' There will be an advance notice provided by the contractor 24-hour advance notice of no parking in work areas. Access will be maintained to all residences and their driveways. When work is occurring directly in front of driveways, the contractor will work with the residence to manage access. Traffic Revisions Flagging crews will maintain one lane; flaggers will assist vehicles alternating through the roadway during work hours. For more information on the project 24-hour project information (888) 471-7339, (360) 825-5236 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG No No No Yes Yes Yes "Flagging Required" "Outages Required" "Locates Required" ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. POTELCO DESIGN AND Signature _________________________________________ Print Name _________________________________________ This design complies with PSE Any/all variations have been Design/Engineering Standards. QUALITY ASSURANCE pre-approved/documented by the appropriate PSE Representative. Date _________________ JOB SITE JOB SITE MAKE NO CHANGES TO THIS JOB WITHOUT PRIOR APPROVAL Notify Customers and Service Area 48 HRS Prior To Planned Outages ORDER#NOTIF#PROJECT PHASE MAINTENANCE O & M SUPERIOR FAILED SILICONE REMOVAL EXPENSE 12022684 101186789 N/A 108164751 OVERHEAD CIRCUIT: MAP # . SCALE 6" = 1 MILE UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP C. YLENNI 253-720-9700 07/08/25 A. NAWFAL 253-509-7147 07/08/25 N/A N/A N/A C. RAVANERA 253-308-8956 07/08/25 REQ-CITY OF RENTON PRE-13 SE 1ST PL CRP 2027 CABLE REMEDIATION PROGRAM 4108 SE 2ND PL, RENTON, WA 98059 N/A N/A N/A 101186789 AS NOTED 1 OF 5 KING N/A N/A QSEPRE NW 15-05-23 N/A N/A 2305E058 2305E088 2305E058 PRE-13 N/A N/A N/A N/A N/A N/A N/A N/A N/A Potelco, Inc.DESIGNED BY 10 1 1 8 6 7 8 9 INDEX PAGE 1 - GENERAL NOTES PAGE 2 - SITE PLAN PAGE 3 - PRE AND POST CONSTRUCTION UG MAPS PAGE 4 - PRIMARY CABLE & CONDUIT DIAGRAM PAGE 5 - EXISTING CABLE MAPPING Overflow Filter fabric walls for Catch Basin Grate dewatering sedimentCollected Sediment Catch Basin Insert MID 9995728 Filter fabric skirt Secured with grate. EROSION CONTROL NOT TO SCALE 2305E088 LEGEND SINGLE PHASE, ONE WIRE/CABLE - 7.2 KV THREE PHASE WIRE/CABLE - 12.5 KV CABLE TERMINATION BUS (J-BOX) NEW OVERHEAD TO UNDERGROUND CABLE OVERHEAD TO UNDERGROUND CABLE TERM. 10T, 15T, 25T, 40T, 100T - INDICATES FUSE SIZE TOTAL UNDERGROUND XFMR (T.U.T.) NEW COMBINATION J-BOX/PADMOUNT XFMR UNDERGROUND COMBINATION J-BOX/XFMR N.T.S. = NOT TO SCALE X.F.M.R. = TRANSFORMER P.E. = POLYETHYLENE ABBREVIATIONS PRIMARY METERING CABLE SPLICE FAULT INDICATOR WILL NOT PHASE (WNØ) NORMAL OPEN (N.O.) FUSED DISCONNECT: SOLID BLADE DISCONNECT HANDHOLE PULL VAULT UNDERGROUND SWITCH UNDERGROUND J-BOX NEW PADMOUNT XFMR NEW UNDERGROUND XFMR PAD MOUNT XFMR ELECTRONIC MARKER COMBINATION J-BOX/PADMOUNT XFMR NEW UNDERGROUND COMBINATION J-BOX/XFMR TERMINATION CABLE TO REPLACE PROPERTY LINE RIGHT OF WAY CENTERLINE EASEMENT CL CABLE TO CUT AND ABANDON Conduit Excavated Dirt Pile ROADSIDE Final Grade 24" Min (ROW) 36" MIN Cover (PVT PROP) 36" MIN 48" Max Backfill (No rocks over 8" diameter) 3" Bedding Clean Native Soil, Sand or 5/8" Minus 12" Typical TRENCH DETAIL NOT TO SCALE 12" Min Shading Clean Native Soil, Sand or 5/8" Minus - A 3" layer of sand, 5/8" minus or clean shading is allowed when excavated native material contains rocks no larger than 8" in diameter. Trench and backfill requirements for primary electric line extension trenches - A 12" layer of sand, 5/8" minus or clean shading is required when excavated native material contains rocks up to 8" in diameter. FOREMAN TO CONTACT REGIONAL CONSTRUCTION MANAGER FOR COVER DEVIATIONS FROM THIS DETAIL PHOTOS AND DETAILED NOTES SHALL BE PROVIDED BY FOREMAN 12" MIN 48" MAX 36" MIN EXISTING PAVEMENT / SIDEWALK VERTICAL SAW CUT LINE CRUSHED SURFACING MATERIAL COMPACT TO 95% MAX DENSITY. EXCAVATION AND HARD RESTORATION DETAIL NOT TO SCALE 12" MIN 3" Sand Bedding or 5/8" Minus 12" Min Sand Shading or 5/8" Minus 12" MIN ASPHALT PATCH, 2" MIN MATCH EXISTING Conduit (ROW) 36" MIN (PVT PROP) 36" MIN For contacts below dial 1-888-CALL PSE (225-5773) Contact Information PSE: PLANNER 355 - 110TH AVE NE BELLEVUE, WA 98004 STEPHEN HARTNETT 425-283-9970 ABANDONING PRIMARY CABLES PSE std. 6825.6200 In a Vault if the cable is ______________________________________________________________________________________ In conduit, -Remove the cable ______________________________________________________________________________________ Not in conduit or it cannot be pulled out, -Cut the cable off approximately one foot from the vault wall. Install a cap on the tail. -When practical, attach the old cable number to the cable stub. ______________________________________________________________________________________ In a Minipad hand hole ______________________________________________________________________________________ In conduit, -Remove the cable ______________________________________________________________________________________ Not in conduit or it cannot be pulled out, -Cut the cable off as much as practical. Install a cap on the tail. -When practical, attach the old cable number to the cable stub. -Stuff the tail into the bottom of the handhole. Be sure the new cables are not trapped by the old cables or the concentric neutrals. ______________________________________________________________________________________ At Risers if the cable is ______________________________________________________________________________________ In Conduit -Remove Cable ______________________________________________________________________________________ Direct buried or it cannot be pulled out, -Cut off the cable at the top of the riser. Install a cap on the tail. and the pole will remain. -When practical, attach the old cable number to the cable stub. ______________________________________________________________________________________ DIRECT BURIED Direct buried or it cannot be pulled out, -Remove the riser. and the pole will be replaced -Cut off old cable just below grade. -Re-fill ground back to existing grade. ______________________________________________________________________________________ DIRECT BURIED Direct buried or it cannot be pulled out, -Cut off the cable just below grade. and the pole will be removed ______________________________________________________________________________________ NOTE: If the pole is to be replaced, remove the abandoned riser and elbow, and stand off brackets (unless they support other conduits). NOTE: If the riser is made of transite material, it shall be removed following procedures in standard 0100.5000, "Transite Pipe Removal and Disposal." _______________________________________________________________________________________ -Remove (not abandon) aboveground transite riser when it is encountered in the field. Belowground transite may be left in place and backfilled. (Transite is a mixture of asbestos and cement. It is nonmetallic, flame-retardant, and resistant to moisture, low temperature, and corrosive agents). -For removal use an approved certified abatement contractor. Call the Environmental Services Department 24-hour pager (206-994-3186) to have a contractor dispatched. Procedure to Abandon Primary Cables: 1. Call the Systems Operator to request a clearance. 2. Follow the directions to ensure the cable is de-energized, apply proper tags as specified in Standard Practice 0201.1011, "Switching and Clearances Handbook," and report back to the Systems Operator. 3. Obtain a clearance from the Systems Operator on the cable to be abandoned. 4. Cut the ends of the cable. 5. The cable number tag may be left on the abandoned cable. NOTE: The cable number shall not be reused. 6. Call the Systems Operator and release the clearance. 7. Remove all "Danger Do Not Operate" tags. 8. The System Operator will then close the O# (Operations number). Existing System: Maintain existing electrical system in service until new system is complete, tested, and ready for service. Disable existing system only to make cutovers and connections as directed by PSE System Operator. Trench Method: CABLE REPLACEMENT Approximate Trench Footage: Abandon Cable Segments: Approximate New 1Ø/3Ø pri. Cable Footage: Approximate 2"/4" Poly Conduit Footage: Replaced Cable Segments: BORE 3,075' 20'/3,055' 0 11 3,520'/465' Vaults: 3,380'/445' Approximate Trench PVT/ROW: 1 FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. VICINITY MAP CARLOS CHAVEZ 07/14/25 C. CHAVEZ 253-691-2840 07/14/25 SE 2ND PL(PAVED) SE 2ND PL BR E M E R T O N P L N E ( P A V E D ) BRE M E T R O N A V E S E 104 4126 4130 4134 4202 4206 4210 4214 4304 4308 4312 107 103 100 123 102108 114 118 202 229 223 129 235 208 214 220 226 232 238 244 250 4206 4212 4218 4102 4108 249 243 4106 4110 4114 4118 4122 101 4111 4117 4203 4207 4211 4215 4305 4309 115 201207 213219 225 2314109 P#2525000760 P#2525000240 P#2525000230 P#2525000220 P#2525000210 P#2525000200 P#2525000190 P#2525000250 P#2525000260 P#2525000270 P#2525000280 P#2525000290 P2525000740 P#2525000730 P#2525000720 P#2525000300 P#2525000310 P#2525000460 P#2525000330P#2525000320 P#2525000340 P#2525000350 P#2525000360 P#2525000450 P#2525000440 P#2525000430 P#2525000420 P#2525000370 P#2525000380 P#2525000390 P#2525000400 P#2525000410 P#2525000180 P#2525000170 P#2525000160 P#2525000150 P#2525000140 P#2525000130 P#2525000120 P#2525500250 P#2525000590 P#2525000600 P#2525000760 P#2525000760 P2525000760 P#2525000530 P#2525000540 P#2525000550 P#2525000560 P#2525000570 P#2525000520 P#2525000510 P#2525000500 P#2525000490 P#2525000480 P#2525000470 P#2525000710 P#2525000700 P#2525000680 P#2525000670 P#2525000770 P#2525000580 4302 P#2525000670 4308 P#2525000660 4314 P#2525000650 241 P2525000640 228 P#2525000040 234 P#2525000030 D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/WD/WD/WD/WD/WD/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W SE 1ST PL (PAVED) SE 1 S T P L ( P A V E D ) VA S H O N A V E S E ( P A V E D ) EOP=35' ROW=60' EOP=30' ROW=50' EOP=30' ROW=50' EOP=30' ROW=50' EOP=30' ROW=50' EOP=30' ROW=50' VA S H O N A V E S E ( P A V E D ) BP-2 8 BP-10 BP-11 BP-12 BP-13 BP-15 BP-21 BP - 2 0 BP-4 BP-18 BP-24 BP-26 BP-27 BP-22 BO R E ~ 1 8 0 ' OPEN TRENCH ~ 5' BO R E ~ 1 6 5 ' BORE ~ 40' BOR E ~ 6 0 ' BORE ~ 65' BORE ~ 180'BORE ~ 190' BORE ~ 150' OPEN TRENCH ~ 45' OPEN TRENCH ~ 50' OPEN TRENCH ~ 10' BO R E ~ 1 2 5 ' ROW=50' EOP=30' ROW=50' BORE ~95' BOR E ~ 6 5 ' BORE ~ 1 5 5 ' BORE ~95 ' OPEN TRE N C H ~ 5 ' OPEN TRENCH ~ 50' R0W=50' BP-14 BP-17 EOP=40' ROW=60'201 P#1623059015 121 P#1623059067 117 P#1623059092 103 P#1623059096 215 P#1623059086 201 P#1623059015 UN I O N A V E S E ( P A V E D ) BP-1 OPEN TRENCH ~ 15' BORE ~ 220' OPEN TRENCH ~ 10' BO R E ~ 2 0 0 ' BP-2 BP-3 D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/WD/WD/W D/W A D A S/W S / W S/W S/W S/W S/ W S/W S / W S/W D/W AD A AD A NEW 4'8" SQ J-BOX ROW=50' EOP=30' BP-5 BP-6 BP - 7 BP- 9 BP - 8 D/WOPEN TRENCH ~ 5' OPEN TRENCH ~ 5' BP-1 6 BP-19 BP-22 BP-25 BORE ~ 75' EOP=30' B O R E ~ 7 0 ' BO R E ~ 6 0 ' OPEN T R E N C H ~ 3 5 ' EOP=30' OPEN TRENCH ~ 25' BO R E ~ 1 1 0 ' BO R E ~ 7 5 ' BP-2 3 BORE ~ 55' BORE ~60' BOR E ~ 6 0 ' BO R E ~ 6 5 ' BP-2 9 S/W S/W BORE ~ 1 3 0 ' BORE ~ 60' BORE ~ 50' SITE PLAN SCALE: 1:50 CIRCUIT FEET REMOVED: 3,713' CIRCUIT FEET ADDED: 3,825' UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP C. YLENNI 253-720-9700 07/08/25 A. NAWFAL 253-509-7147 07/08/25 N/A N/A N/A C. RAVANERA 253-308-8956 07/08/25 REQ-CITY OF RENTON PRE-13 SE 1ST PL CRP 2027 CABLE REMEDIATION PROGRAM 4108 SE 2ND PL, RENTON, WA 98059 N/A N/A N/A 101186789 AS NOTED 2 OF 5 KING N/A N/A QSEPRE NW 15-05-23 N/A N/A 2305E058 2305E088 2305E058 PRE-13 N/A N/A N/A N/A N/A N/A N/A N/A N/A 10 1 1 8 6 7 8 9 Potelco, Inc.DESIGNED BY Electric Cable in HDPE Conduit Final Grade 24" Typical (6" Min) 36" Min Cover Backfill shall not damage the conduit. Backfill hard surface w/ while directional drilling 36" Min Depth Final Grade 24" Typical (6" Min) 8' L o n g crushed rock 5/8 minus Backfill soft surface with clean natural material PLAN VIEWTYPICAL BORE COVER Will maintain 36" Min. depth BORE PIT DETAIL NOT TO SCALE BORE PIT POT HOLE *NOTE:BORE PITS, TRENCH HATCHING & POTHOLES ARE NOT SHOWN TO SCALE FOR VISUAL PURPOSES. PLEASE SEE BORE PIT DETAIL FOR TYP. BORE PIT & TRENCH DIMENSIONS. 4" Min Shading Clean Native Soil, Sand or 5/8" Minus 2" Min Bedding Clean Native Soil, Sand or 5/8" Minus UNITS OF PROPERTY INSTALL ONLY CROSSARMS MATERIAL QTY DIST. WOOD DIST. FIBERGLASS DIST. STEEL DIST. OTHERS TRANS. WOOD TRANS. FIBERGLASS TRANS. STEEL TRANS. OTHERS UNITS OF PROPERTY INSTALL ONLY LINE FIXTURES MATERIAL QTY DIST. ARRESTERS DIST. CUTOUTS DIST. INSULATORS TRANS. ARRESTERS TRANS. INSULATORS UNITS OF PROPERTY REMOVAL ONLY MATERIAL QTY DIST. ARRESTERS DIST. CUTOUTS DIST. INSULATORS TRANS. ARRESTERS TRANS. INSULATORS CROSSARMS MAPS & RECORDS NOTE: 1) UPDATE THE LOCATION OF THE FOLLOWING EQUIPMENT. J01 IS APPROX. 8' NORTH & 18' WEST OF EXISTING PSE MAPS LOCATION. J02 IS APPROX. 5' NORTH & 12' EAST OF EXISTING PSE MAPS LOCATION. J03 IS APPROX. 33' NORTH & 10' WEST OF EXISTING PSE MAPS LOCATION. VAULT & EQUIPMENT TABLE SITE GRID NUMBER VAULT SIZE & COVER TYPE & SIZE EQUIPMENT IN VAULT PRIMARY BUSHINGS TRANSFORMER ID NUMBERS (COMPANY ID) REMARKS LB DC J04 NEW 317894 167207 HH 4'-8" X 4'-8" X 3'-6" W/3' DPC H20 MATID:7663900, 9996161 J-BOX BELOW GRADE W/ 2-4 POS. J-BUS MATID: 7625900 4 4 ADD ADDITIONAL 1-4 POS J-BUS INSTALL NEW 4'-8" x 4'-8" x 3'-6" J-BOX WIRE CREW TO INSTALL GRID NUMBERS J01 317848 167145 EXISTING COMBO VAULT J-BOX BELOW GRADE W/ 3-4 POS. J-BUS 37.5kVA TUT XFMR 120/240v EXISTING 5 - REPLACE ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS J02 317909 167232 EXISTING JUNCTION BOX J-BOX BELOW GRADE W/ 3-4 POS. J-BUS EXISTING 2 - REPLACE ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS J03 317867 167123 EXISTING JUNCTION BOX J-BOX BELOW GRADE W/ 3-4 POS. J-BUS EXISTING 3 - REPLACE ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS V01 317878 167140 EXISTING VAULT 50kVA PM XFMR 120/240v EXISTING 2 - REPLACE ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS V02 317901 167156 EXISTING VAULT 75kVA PM XFMR 120/240v EXISTING 2 - REPLACE ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS V03 317894 167193 EXISTING VAULT 75kVA PM XFMR 120/240v EXISTING 2 - REPLACE ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS V04 317894 167229 EXISTING VAULT 75kVA PM XFMR 120/240v EXISTING 2 - REPLACE ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS V05 317870 167206 EXISTING VAULT 75kVA PM XFMR 120/240v EXISTING 2 - REPLACE ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS V06 317874 167177 EXISTING VAULT 75kVA PM XFMR 120/240v EXISTING 2 - REPLACE ELBOWS & CONDUCTORS WIRE CREW TO INSTALL GRID NUMBERS TOTALS :26 4 C. CHAVEZ 253-691-2840 07/14/25 BØ30056 CUT & ABANDON BØ30055 CUT & ABANDON BØ30053 CUT & ABANDON CØ30059 CUT & ABANDON CØ30060 CUT & ABANDON BØ30057 CUT & ABANDON CØ30058 CUT & ABANDON VASHON AVE SE VA S H O N A V E S E SE 1ST PL SE 1ST PL SE 2ND PL SE 2ND PL BRE M E R T O N A V E S E UN I O N A V E S E BR E M E R T O N P L N E CØ30054 CUT & ABANDON AØ32928 BØ32929 CØ32930 EXISTING TO REMAIN AØ32923 BØ32924 CØ32935 EXISTING TO REMAIN AØEGU206 EXISTING TO REMAIN JUMBER BØEGQ569 EXISTING TO REMAIN AØ30043 BØ30044 CØ30045 CUT & ABANDON AØ58051 AØ58054 BØ58052 EXISTING TO REMAIN AØ58048 BØ58049 CØ58050 EXISTING TO REMAIN AØ30046 BØ30047 CØ30048 EXISTING TO REMAIN AØEJQ222 EXISTING TO REMAIN AØEJQ222 EXISTING TO REMAIN AØ32928 BØ32929 CØ32930 EXISTING TO REMAIN AØ32923 BØ32924 CØ32935 EXISTING TO REMAIN BØEKK928 AØEGU206 EXISTING TO REMAIN AØ30046 BØ30047 CØ30048 EXISTING TO REMAIN BØEGQ569 EXISTING TO REMAIN AØEKK925 BØEKK926 CØEKK927 CØEKK937 VASHON AVE SE VA S H O N A V E S E SE 1ST PL SE 2ND PL BR E M E R T O N P L N E AØEGQ566 BØEGQ567 CØEGQ568 EXISTING TO REMAIN AØ58051 AØ58054 BØ58052 EXISTING TO REMAIN AØ58048 BØ58049 CØ58050 EXISTING TO REMAIN BØEKK929 BØEKK930 BØEKK931 CØEKK936 CØEKK935 CØEKK934 NEW 4'8" SQ J-BOX CØEKK933 BØEKK932 N.O. PRE-CONSTRUCTION UNDERGROUND MAP:2305E058 SCALE: 1:100 UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP C. YLENNI 253-720-9700 07/08/25 A. NAWFAL 253-509-7147 07/08/25 N/A N/A N/A C. RAVANERA 253-308-8956 07/08/25 REQ-CITY OF RENTON PRE-13 SE 1ST PL CRP 2027 CABLE REMEDIATION PROGRAM 4108 SE 2ND PL, RENTON, WA 98059 N/A N/A N/A 101186789 AS NOTED 3 OF 5 KING N/A N/A QSEPRE NW 15-05-23 N/A N/A 2305E058 2305E088 2305E058 PRE-13 N/A N/A N/A N/A N/A N/A N/A N/A N/A 10 1 1 8 6 7 8 9 Potelco, Inc.DESIGNED BY POST-CONSTRUCTION UNDERGROUND MAP:2305E058 SCALE: 1:100 ABANDONED / REMOVE / REPLACED CABLE SCHEDULE CABLE NO. SAP EQUIP LOCATIONS CABLE (LF) EST EXISTING CABLE MFG. NAME EXISTING CABLE MFG. DATE ABANDONED CABLE LEFT IN PLACE ABANDON CIRCUITRYFROM TO 30054 10522299 J01 V06 527 YES NO 30053 10522287 J01 V01 438 YES NO 30055 10522309 V01 V02 351 YES NO 30056 10522320 V02 V03 433 YES NO 30057 10522330 V03 J02 553 YES NO 30058 10522343 V05 V06 327 YES NO 30059 10522353 V05 V04 397 YES NO 30060 10522364 J02 V04 194 YES NO 30043 10522176 J01 J03 493 30044 10522188 J01 J03 493 30045 10522198 J01 J03 493 TOTAL CIRCUIT FEET 3,713' TOP VIEW Excavation - 10-1/3 cubic yards SIDE VIEW Rock Crushed 6" 4'-4" 2" 8' 8' 4'-8" 3'-6" 4'-8" 6" 3,600 lbs 1,300 - 1,365 lbs Not to scale 6055.1010 VAULT & EXCAVATION DETAIL Cables should enter the vault so that all of the cables will lay in the same direction. TOP VIEW J- BOX CABLE ENTRY DETAIL Not to scale C. CHAVEZ 253-691-2840 07/14/25 AØEJQ222 EXISTING TO REMAIN AØ32928 BØ32929 CØ32930 EXISTING TO REMAIN AØ32923 BØ32924 CØ32935 EXISTING TO REMAIN AØEGU206 EXISTING TO REMAIN JUMPER AØ30046 BØ30047 CØ30048 EXISTING TO REMAIN BØEGQ569 EXISTING TO REMAIN 27 6 . 7 3 l b s 2 5 8 . 9 6 l b s 190 . 6 8 l b s 2 0 2 . 6 3 l b s 141.48 lbs 1 4 0 . 4 6 l b s 18 2 . 6 3 l b s 1 8 7 . 8 7 l b s 268.19 lbs 300.75 lbs 133.45 lbs 133.63 lbs 141.20 lbs 137.24 lbs 15 9 . 6 7 l b s 1 6 6 . 3 0 l b s VASHON AVE SE VA S H O N A V E S E SE 1ST PL SE 2ND PL BR E M E R T O N P L N E AØ58051 AØ58054 BØ58052 EXISTING TO REMAIN AØ58048 BØ58049 CØ58050 EXISTING TO REMAIN AØEGQ566 BØEGQ567 CØEGQ568 EXISTIING TO REMAIN BØEKK928 AØEKK925 BØEKK926 CØEKK927 CØEKK937 BØEKK929 BØEKK930 BØEKK931 CØEKK936 CØEKK935 CØEKK933 68 5 . 7 6 l b s 6 9 1 . 0 1 l b s NEW 4'8" SQ J-BOX BØEKK932 90.50 lbs 82.59 lbs N.O. CØEKK934 14 4 . 5 5 l b s 1 3 8 . 9 6 l b s 2-2" - L______' 1-2" - L______' 1-2" - L______' 1-2" - L______' 2-2" - L______' 1-2" - L______' 1-2" - L______' 1-2" - L______' 2-2" - L______' 2-2" - L______' 2-2" - L______' 2-2" - L______' 2-2" - L______' 2-2" - L______' VASHON AVE SE VA S H O N A V E S E SE 1ST PL SE 2ND PL BR E M E R T O N P L N E 1-4" - L______' NEW 4'8" SQ J-BOX 2-2" - L______' 1-2" - L______' 2-2", 1-4" - L______' UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP C. YLENNI 253-720-9700 07/08/25 A. NAWFAL 253-509-7147 07/08/25 N/A N/A N/A C. RAVANERA 253-308-8956 07/08/25 REQ-CITY OF RENTON PRE-13 SE 1ST PL CRP 2027 CABLE REMEDIATION PROGRAM 4108 SE 2ND PL, RENTON, WA 98059 N/A N/A N/A 101186789 AS NOTED 4 OF 5 KING N/A N/A QSEPRE NW 15-05-23 N/A N/A 2305E058 2305E088 2305E058 PRE-13 N/A N/A N/A N/A N/A N/A N/A N/A N/A 10 1 1 8 6 7 8 9 Potelco, Inc.DESIGNED BY PRIMARY CONDUIT DIAGRAM NOT TO SCALE PRIMARY CABLE DIAGRAM NOT TO SCALE CIVIL CREW NOTE: ALL 2" - 90° BENDS MIN 48" RADIUS SCH-80 PVC ALL 2" - 45° BENDS SCH-80 PVC - ALL CONDUITS SHALL BE CAPPED AT EACH END UNTIL CABLE IS INSTALLED PRIMARY CABLE & CONDUIT TABLE (FOREMAN TO COMPLETE) LOCATION CONDUIT PRIMARY CABLE QTY OF LUBE (gal.)REMARKS FROM TO SIZE (in)QTY DESIGN LENGTH (ft) ACTUAL LENGTH (ft) TYPE BENDS PULL (lbs) PULL REV (lbs) SIZE DESIGN LENGTH (ft) ACTUAL LENGTH (ft) CABLE NUMBERS MANUFACTURING INFORMATION For Feeder Cable Only Check applicable box DB120 HDPE SCH 80 90 45 22 11 A B C MANUFACTURER COMPOUND YEAR TAPE CN #4/0 NEU DESIGN AS BUILT J01 J03 4 1 445 691.01 685.76 1/0 AL JKT 465 EKK925 EKK626 EKK927 1.4 J01 V01 2 1 470 190.68 202.63 1/0 AL JKT 485 -EKK928 -1.5 V01 V02 2 1 360 166.30 159.67 1/0 AL JKT 370 -EKK929 -1.2 V02 V03 2 1 425 137.24 141.20 1/0 AL JKT 435 -EKK930 -1.4 V03 J04 2 1 190 82.59 90.50 1/0 AL JKT 205 -EKK931 -0.6 J04 J02 2 1 345 300.75 268.19 1/0 AL JKT 365 -EKK932 -1.1 J04 V04 2 1 240 133.45 133.63 1/0 AL JKT 255 --EKK933 0.8 V04 J02 2 1 205 144.55 138.96 1/0 AL JKT 220 --EKK934 0.7 J04 V05 2 1 260 182.63 187.87 1/0 AL JKT 275 --EKK935 0.8 V05 V06 2 1 330 141.48 140.46 1/0 AL JKT 340 --EKK936 1.1 V06 J01 2 1 555 276.73 258.96 1/0 AL JKT 570 --EKK937 1.8 TOTAL 4"445'TOTAL 3Ø 465'TOTAL LUBE 12.4 TOTAL 2"3,380'TOTAL 1Ø 3,520' ALL 4" - 90° BENDS MIN 60" RADIUS SCH-80 PVC ALL 4" - 45° BENDS SCH-80 PVC C. CHAVEZ 253-691-2840 07/14/25 SE 2ND PL(PAVED) SE 2ND PL BR E M E R T O N P L N E ( P A V E D ) BRE M E T R O N A V E S E 104 4126 4130 4134 4202 4206 4210 4214 4304 4308 4312 107 103 100 123 102108 114 118 202 229 223 129 235 208 214 220 226 232 238 244 250 4206 4212 4218 4102 4108 249 243 4106 4110 4114 4118 4122 101 4111 4117 4203 4207 4211 4215 4305 4309 115 201207 213219 225 2314109 P#2525000760 P#2525000240 P#2525000230 P#2525000220 P#2525000210 P#2525000200 P#2525000190 P#2525000250 P#2525000260 P#2525000270 P#2525000280 P#2525000290 P2525000740 P#2525000730 P#2525000720 P#2525000300 P#2525000310 P#2525000460 P#2525000330P#2525000320 P#2525000340 P#2525000350 P#2525000360 P#2525000450 P#2525000440 P#2525000430 P#2525000420 P#2525000370 P#2525000380 P#2525000390 P#2525000400 P#2525000410 P#2525000180 P#2525000170 P#2525000160 P#2525000150 P#2525000140 P#2525000130 P#2525000120 P#2525500250 P#2525000590 P#2525000600 P#2525000760 P#2525000760 P2525000760 P#2525000530 P#2525000540 P#2525000550 P#2525000560 P#2525000570 P#2525000520 P#2525000510 P#2525000500 P#2525000490 P#2525000480 P#2525000470 P#2525000710 P#2525000700 P#2525000680 P#2525000670 P#2525000770 P#2525000580 4302 P#2525000670 4308 P#2525000660 4314 P#2525000650 241 P2525000640 228 P#2525000040 234 P#2525000030 D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/WD/WD/WD/WD/WD/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W SE 1ST PL (PAVED) SE 1 S T P L ( P A V E D ) VA S H O N A V E S E ( P A V E D ) LEGEND CLP= CENTER LINE OF PAVEMENT EOB= EDGE OF BUILDING PROP= EDGE OF PROPERTY LINE RM= ROAD MONUMENT EOR= EDGE OF ROAD EXISTING CABLES LOCATION PROVIDED BY: LOCATES TICKET # __________________ EOP=35' ROW=60' EOP=30' ROW=50' EOP=30' ROW=50' EOP=30' ROW=50' EOP=30' ROW=50' EOP=30' ROW=50' EXISTING ___' E EOR PROPOSED 1' E EOR BUILT ___' E EOR EXISTING ___' S EOR PROPOSED 3' S EOR BUILT ___' S EOR EXISTING ___' S EOR PROPOSED 3' S EOR BUILT ___' S EOR EXISTING ___' S EOR PROPOSED 3' S EOR BUILT ___' S EOR EXISTING ___' E EOR PROPOSED 3' E EOR BUILT ___' E EOR EXISTING ___' W EOR PROPOSED 3' W EOR BUILT ___' W EOR EXISTING ___' S EOR PROPOSED 3' S EOR BUILT ___' S EOR EXISTING ___' S EOR PROPOSED 3' S EOR BUILT ___' S EOR EXISTING ___' E EOR PROPOSED 3' E EOR BUILT ___' E EOR VA S H O N A V E S E ( P A V E D ) BP-2 8 BP-10 BP-11 BP-12 BP-13 BP-15 BP-21 BP - 2 0 BP-4 BP-18 BP-24 BP-26 BP-27 BP-22 BO R E ~ 1 8 0 ' OPEN TRENCH ~ 5' BO R E ~ 1 6 5 ' BORE ~ 40' BOR E ~ 6 0 ' BORE ~ 65' BORE ~ 180'BORE ~ 190' BORE ~ 150' OPEN TRENCH ~ 45' OPEN TRENCH ~ 50' OPEN TRENCH ~ 10' BO R E ~ 1 2 5 ' ROW=50' EOP=30' ROW=50' BORE ~95' BOR E ~ 6 5 ' BORE ~ 1 5 5 ' BORE ~95' OPEN TRE N C H ~ 5 ' OPEN TRENCH ~ 50' R0W=50' BP-14 BP-17 EOP=40' ROW=60'201 P#1623059015 121 P#1623059067 117 P#1623059092 103 P#1623059096 215 P#1623059086 221 P#1623059055 201 P#1623059015 UN I O N A V E S E ( P A V E D ) BP-1 EXISTING ___' E EOR PROPOSED 3' E EOR BUILT ___' E EOR OPEN TRENCH ~ 15' BORE ~ 220' OPEN TRENCH ~ 10' BO R E ~ 2 0 0 ' BP-2 BP-3 EXISTING ___' S EOR PROPOSED 3' S EOR BUILT ___' S EOR D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/W D/WD/WD/W D/W A D A S/W S / W S/W S/W S/W S/ W S/W S / W S/W D/W AD A AD A NEW 4'8" SQ J-BOX ROW=50' EOP=30' BP-5 BP-6 BP - 7 BP- 9 BP - 8 D/WOPEN TRENCH ~ 5' OPEN TRENCH ~ 5' BP-1 6 BP-19 BP-22 BP-25 BORE ~ 75' EOP=30' B O R E ~ 7 0 ' BO R E ~ 6 0 ' OPEN T R E N C H ~ 3 5 ' EOP=30' OPEN TRENCH ~ 25' BO R E ~ 1 1 0 ' BO R E ~ 7 5 ' BP-2 3 BORE ~ 55' BORE ~60' BOR E ~ 6 0 ' BO R E ~ 6 5 ' BP-2 9 S/W S/W BORE ~ 1 3 0 ' BORE ~ 60' BORE ~ 50' EXISTING CABLE MAPPING SCALE: 1:50 UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP C. YLENNI 253-720-9700 07/08/25 A. NAWFAL 253-509-7147 07/08/25 N/A N/A N/A C. RAVANERA 253-308-8956 07/08/25 REQ-CITY OF RENTON PRE-13 SE 1ST PL CRP 2027 CABLE REMEDIATION PROGRAM 4108 SE 2ND PL, RENTON, WA 98059 N/A N/A N/A 101186789 AS NOTED 5 OF 5 KING N/A N/A QSEPRE NW 15-05-23 N/A N/A 2305E058 2305E088 2305E058 PRE-13 N/A N/A N/A N/A N/A N/A N/A N/A N/A 10 1 1 8 6 7 8 9 Potelco, Inc.DESIGNED BY VOLUME OF DISTURBANCE TABLE TYPE DESCRIPTION PROPERTY CLASSIFCATION SIZE (FT) REM CU YD (APPX) GRAVEL FILL CU YD (APPX) COMMON SURFACE TYPES REMARKS BP-1 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-2 BORE PIT ROW 2 X 14 X 3 3.1 3.1 ASPHALT BP-3 BORE PIT ROW 2 X 8 X 3 1.8 1.8 ASPHALT BP-4 BORE PIT ROW 2 X 14 X 3 3.1 3.1 ASPHALT BP-5 BORE PIT ROW 2 X 14 X 3 3.1 3.1 CONCRETE BP-6 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-7 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-8 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-9 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-10 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-11 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-12 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-13 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-14 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-15 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-16 BORE PIT ROW 2 X 8 X 3 1.8 1.8 ASPHALT BP-17 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-18 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-19 BORE PIT ROW 2 X 14 X 3 3.1 3.1 ASPHALT BP-20 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-21 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-22 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-23 BORE PIT ROW 2 X 14 X 3 3.1 3.1 CONCRETE BP-24 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-25 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-26 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-27 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-28 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE BP-29 BORE PIT ROW 2 X 8 X 3 1.8 1.8 CONCRETE OPEN TRENCH TRENCH PVT PROP 1 X 20 X 3 2.2 2.2 GRASS OPEN TRENCH TRENCH ROW 1 X 35 X 3 3.9 3.9 GRASS OPEN TRENCH TRENCH ROW 1 X 85 X 3 9.4 9.4 ASPHALT OPEN TRENCH TRENCH ROW 1 X 120 X 3 13.3 13.3 CONCRETE TOTAL PVT PROP CU YDS (APPX)2.2 2.2 TOTAL ROW CU YDS (APPX)84.9 84.9 TOTAL CU YDS (APPX)87.1 87.1 C. CHAVEZ 253-691-2840 07/14/25 NEW 4'8" SQ J-BOX BØ30056 CUT & ABANDON BØ30055 CUT & ABANDON BØ30053 CUT & ABANDON CØ30059 CUT & ABANDON CØ30060 CUT & ABANDON BØ30057 CUT & ABANDON CØ30058 CUT & ABANDON VASHON AVE SE VA S H O N A V E S E SE 1ST PL SE 1ST PL SE 2ND PL SE 2ND PL BRE M E R T O N A V E S E UN I O N A V E S E BR E M E R T O N P L N E CØ30054 CUT & ABANDON AØ32928 BØ32929 CØ32930 EXISTING TO REMAIN AØ32923 BØ32924 CØ32935 EXISTING TO REMAIN AØEGU206 EXISTING TO REMAIN JUMBER BØEGQ569 EXISTING TO REMAIN AØ30043 BØ30044 CØ30045 CUT & ABANDON AØ58051 AØ58054 BØ58052 EXISTING TO REMAIN AØ58048 BØ58049 CØ58050 EXISTING TO REMAIN AØ30046 BØ30047 CØ30048 EXISTING TO REMAIN AØEJQ222 EXISTING TO REMAIN 10 1 1 8 6 7 8 9 FOREMAN MAP: U MAP # / UG MAP # . SCALE: 1" = 100' 2305E058 2305E058