HomeMy WebLinkAboutP_Final_Construction_Drawings_EVCS_Best Western-Renton_v2_20241204PROJECT INFORMATION BEST WESTERN PLUS RENTON INN - RENTON, WA PROJECT DESCRIPTION CS-1 CODE REVIEWSITE INFORMATION AERIAL MAPVICINITY MAP DO NOT SCALE DRAWINGS 1850 MAPLE VALLEY HWY RENTON, WA 98057 THESE DRAWINGS ARE FORMATTED TO BE FULL SIZE AT 22"x34". CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. COVER SHEET SITE NAME:BEST WESTERN PLUS RENTON INN EVCS PROJECT NUMBER:NA-24-000834 SITE ADDRESS:1850 MAPLE VALLEY HWYRENTON, WA 98057 JURISDICTION:CITY OF RENTON ZONING CA (COMMERCIAL ARTERIAL) PARCEL ID:172305-9100 SITE COORDINATES:N47° 29' 0.23" (N47.483397°) (NAD83) W122° 11' 40.12" (W122.194478°) (NAD83) GROUND ELEVATION:70.0'± (NAVD88) PROPERTY OWNER NAME:VIRK HOPSTALITY RENTON, L.L.C. PROPERTY OWNER ADDRESS:8815 SW SUN PLACE WILSONVILLE, OR 97070 POWER COMPANY:PUGET SOUND ENERGY PROJECT MANAGER:JAYSON NARSHALL11800 CLARK STREETARCADIA, CA 91006 ENGINEER CONTACT:RICHARD B. HALL, AIA, NCARB (425) 806-1869 RHALL@LDCCORP.COM LICENSE # 8828, WASHINGTON 1.INSTALL (1) UTILITY TRANSFORMER 2.INSTALL (1) SWITCHGEAR ASSEMBLY 3.INSTALL (4) NOODOE DC150P DISPENSERS 4.INSTALL (1) NOODOE AC7LC L2 DISPENSER SITE SITE SCALE: N.T.S.SCALE: N.T.S. NN SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT 2 12-5-24 S&S PPK ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING CODES: BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: CONSTRUCTION TYPE: 2021 WASHINGTON STATE BUILDING CODE (AMENDED 2021 IBC) 2023 WASHINGTON STATE ELECTRICAL CODE (AMENDED NFPA 70, 2023) 2021 WASHINGTON FIRE BUILDING CODE (AMENDED 2021 IFC) U (UTILITY) IIB Know what's below. Call before you dig. CALL BEFORE YOU DIG DRAWING INDEX SHEET NUMBER SHEET TITLE CS-1 COVER SHEET GN-1 GENERAL NOTES GN-2 GENERAL NOTES A-1 OVERALL SITE PLAN A-2 SITE PREPARATION PLAN A-3 PROPOSED LAYOUT L-1 LANDSCAPE PLAN L-2 LANDSCAPE PLAN D-1 CONSTRUCTION DETAILS D-2 CONSTRUCTION DETAILS D-3 CONSTRUCTION DETAILS D-4 CONSTRUCTION DETAILS E-1 UTILITY PLAN E-2 ELECTRICAL PLAN E-3 ONE-LINE DIAGRAM E-4 ELECTRICAL CONDUIT ELEVATION & DETAILS E-6 GROUNDING DETAILS GN-1 GENERAL NOTES SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT 2 12-5-24 S&S PPK GENERAL CONSTRUCTION NOTES ELECTRICAL NOTES GENERAL SITE NOTES FOR THE PURPOSE OF CONSTRUCTION DRAWINGS, THE FOLLOWING DEFINITIONS SHALL APPLY GENERAL CONTRACTOR: SAI CONSTRUCTION OWNER: ELECTRIFY AMERICA 1. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS. 2. THE GENERAL CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. GENERAL CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF WORK. 4. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS. 5.UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 6. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS THE MINIMUM REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF WORK AND PREPARED BY THE ENGINEER PRIOR TO PROCEEDING WITH WORK. 7. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 8. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE ENGINEER PRIOR TO PROCEEDING. 9. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA, ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS AND THE LOCAL JURISDICTION. 10. THE GENERAL CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK ACTIVITIES WITH OTHER DISCIPLINES. 11. CONSTRUCTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT EXPERIENCED WORKMAN IN ACCORDANCE WITH APPLICABLE CODES AND THE BEST ACCEPTED PRACTICE. 12. WORK PREVIOUSLY COMPLETED IS REPRESENTED BY LIGHT SHADED LINES AND NOTES. THE SCOPE OF WORK FOR THIS PROJECT IS REPRESENTED BY DARK SHADED LINES AND NOTES. CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR OF ANY EXISTING CONDITIONS THAT DEVIATE FROM THE DRAWINGS PRIOR TO BEGINNING CONSTRUCTION. 13. THE CONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE CONSTRUCTION MANAGER 48 HOURS PRIOR TO COMMENCEMENT OF WORK. 14. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER. 15. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 16. THE GENERAL CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR ALL TRADES AND CONTRACTORS TO THE SITE AND/OR BUILDING. 17. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FOR THE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION. 18. THE GENERAL CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. 19. THE CONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS WITH A RATING OF NOT LESS THAN 2-A:10-B:C AND SHALL BE WITHIN 25 FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF WHERE THE WORK IS BEING COMPLETED DURING CONSTRUCTION. 20. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY THE ENGINEER. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. THE CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS SHALL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION, B) CONFINED SPACE, C) ELECTRICAL SAFETY, AND D) TRENCHING & EXCAVATION. 22. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED, CAPPED, PLUGGED OR OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, AS DIRECTED BY THE ENGINEER, AND SUBJECT TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 23. THE AREAS OF THE OWNER'S PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION. 24. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE FEDERAL AND LOCAL JURISDICTION FOR EROSION AND SEDIMENT CONTROL. 25. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 26. THE SUBGRADE SHALL BE BROUGHT TO A SMOOTH UNIFORM GRADE AND COMPACTED TO 95 PERCENT STANDARD PROCTOR DENSITY UNDER PAVEMENT AND STRUCTURES AND 80 PERCENT STANDARD PROCTOR DENSITY IN OPEN SPACE. ALL TRENCHES IN PUBLIC RIGHT OF WAY SHALL BE BACKFILLED WITH FLOWABLE FILL OR OTHER MATERIAL PRE-APPROVED BY THE LOCAL JURISDICTION. 27. ALL NECESSARY RUBBISH, STUMPS, DEBRIS, STICKS, STONES, AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LAWFUL MANNER. 28. ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS, CATALOGS, SHOP DRAWINGS, AND OTHER DOCUMENTS SHALL BE TURNED OVER TO THE GENERAL CONTRACTOR AT COMPLETION OF CONSTRUCTION AND PRIOR TO PAYMENT. 29. THE CONTRACTOR SHALL SUBMIT A COMPLETE SET OF AS-BUILT REDLINES TO THE GENERAL CONTRACTOR UPON COMPLETION OF PROJECT AND PRIOR TO FINAL PAYMENT. 30. THE CONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION. 31. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE, AND IS NOT FOR HUMAN HABITATION (NO HANDICAP ACCESS REQUIRED). 32. NO OUTDOOR STORAGE OR SOLID WASTE CONTAINERS ARE PROPOSED. 33. CONTRACTORS SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. IF CONTRACTOR CANNOT OBTAIN A PERMIT, THEY MUST NOTIFY THE GENERAL CONTRACTOR IMMEDIATELY. 34. THE CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 35. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND/OR DRAWINGS PROVIDED BY THE SITE OWNER. CONTRACTORS SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 1. THE ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ANY/ALL ELECTRICAL WORK INDICATED. ANY/ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH DRAWINGS AND ANY/ALL APPLICABLE SPECIFICATIONS. IF ANY PROBLEMS ARE ENCOUNTERED BY COMPLYING WITH THESE REQUIREMENTS, CONTRACTOR SHALL NOTIFY 'CONSTRUCTION MANAGER' AS SOON AS POSSIBLE, AFTER THE DISCOVERY OF THE PROBLEMS, AND SHALL NOT PROCEED WITH THAT PORTION OF WORK, UNTIL THE 'CONSTRUCTION MANAGER' HAS DIRECTED THE CORRECTIVE ACTIONS TO BE TAKEN. 2. THE ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE THEMSELVES WITH ANY/ALL CONDITIONS AFFECTING ELECTRICAL AND COMMUNICATION INSTALLATION AND MAKE PROVISIONS AS TO THE COST THEREOF. THE CONDITION OF EXISTING ELECTRICAL EQUIP., LIGHT FIXTURES, ETC., THAT ARE PART OF THE FINAL SYSTEM, SHALL BE VERIFIED BY THE CONTRACTOR, PRIOR TO THE SUBMITTAL OF HIS BID. FAILURE TO COMPLY WITH THIS PARAGRAPH WILL IN NO WAY RELIEVE CONTRACTOR OF PERFORMING ALL WORK NECESSARY FOR A COMPLETE AND WORKING SYSTEM. 3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC AND ALL CODES AND LOCAL ORDINANCES OF THE LOCAL POWER COMPANIES HAVING JURISDICTION AND SHALL INCLUDE BUT NOT BE LIMITED TO: A. UL - UNDERWRITERS LABORATORIES B. NEC - NATIONAL ELECTRICAL CODE C. NEMA - NATIONAL ELECTRICAL MANUFACTURERS ASSOC. D. OSHA - OCCUPATIONAL SAFETY AND HEALTH ACT E. SBC - STANDARD BUILDING CODE F. NFPA - NATIONAL FIRE PROTECTION ASSOCIATION 4. DO NOT SCALE ELECTRICAL DRAWINGS, REFER TO SITE PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT, BUT CONFIRM WITH 'CONSTRUCTION MANAGER' ANY SIZES AND LOCATIONS WHEN NEEDED. 5. EXISTING SERVICES: THE CONTRACTOR SHALL NOT INTERRUPT EXISTING SERVICES WITHOUT WRITTEN PERMISSION OF THE OWNER. 6. THE CONTRACTOR SHALL PAY FOR ANY/ALL PERMITS, FEES, INSPECTIONS AND TESTING. THE CONTRACTOR IS TO OBTAIN PERMITS AND APPROVED SUBMITTALS PRIOR TO THE WORK BEGINNING OR ORDERING THE EQUIPMENT. 7. THE TERM "PROVIDE" USED IN CONSTRUCTION DOCUMENTS AND SPECIFICATIONS, INDICATES THAT THE CONTRACTOR SHALL FURNISH AND INSTALL. 8. THE CONTRACTOR SHALL CONFIRM WITH LOCAL UTILITY COMPANY ANY/ALL REQUIREMENTS SUCH AS THE: LUG SIZE RESTRICTIONS, CONDUIT ENTRY, SIZE OF TRANSFORMERS, SCHEDULED DOWNTIME FOR THE OWNERS' CONFIRMATION, ETC. ANY/ALL CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER, PRIOR TO BEGINNING ANY WORK. 9.CONDUCTORS: CONTRACTOR SHALL USE 98% CONDUCTIVITY COPPER OR ALUMINUM WITH TYPE (THWN-2) INSULATION, 600 VOLT, COLOR CODED UNLESS SPECIFIED DIFFERENTLY ON DRAWINGS. 10. ALL (THWN-2) WIRING INSTALLATIONS TO FOLLOW MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. 11. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET/DAMP LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. 12. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF THE CONSTRUCTION. CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS FOR THE EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. CONTRACTOR IS TO PROVIDE ALL ELECTRICAL EQUIPMENT UNLESS OTHERWISE DIRECTED. 13. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS, WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIONAL AND SUBJECT TO REGULATORY INSPECTION AND APPROVAL BY CONSTRUCTION MANAGER. 14. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 15. CONTRACTOR SHALL GUARANTEE ANY/ALL MATERIALS AND WORK FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE YEAR FROM DATE OF ACCEPTANCE. 16. THE CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ANY ADDITIONAL CHARGE AND SHALL INCLUDE THE REPLACEMENT OR THE REPAIR OF ANY OTHER PHASE OF THE INSTALLATION, WHICH MAY HAVE BEEN DAMAGED THEREIN. 17. ADEQUATE AND REQUIRED LIABILITY INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LOSS AND ANY/ALL PROPERTY DAMAGE FOR THE DURATION OF WORK. 18. PROVIDE AND INSTALL CONDUIT, CONDUCTORS, PULL WIRES, BOXES, COVER PLATES AND DEVICES FOR ALL OUTLETS AS INDICATED. 19. TRENCHING AND BACKFILL: THE CONTRACTOR SHALL PROVIDE FOR ALL UNDERGROUND INSTALLED CONDUIT AND/OR CABLES INCLUDING EXCAVATION AND BACKFILLING AND COMPACTION. REFER TO GENERAL SITE WORK NOTES. 20. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW AND SHALL APPEAR ON THE LIST OF U.L. APPROVED ITEMS AND SHALL MEET OR EXCEED THE REQUIREMENTS OF THE NEC, NEMA AND IEEE. 21. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OR MANUFACTURES CATALOG INFORMATION OF ANY/ALL LIGHTING FIXTURES, SWITCHES AND ALL OTHER ELECTRICAL ITEMS FOR APPROVAL BY THE CONSTRUCTION MANAGER PRIOR TO INSTALLATION. 22. ANY CUTTING OR PATCHING DEEMED NECESSARY FOR ELECTRICAL WORK IS THE ELECTRICAL CONTRACTORS RESPONSIBILITY AND SHALL BE INCLUDED IN THE COST FOR WORK AND PERFORMED TO THE SATISFACTION OF THE 'CONSTRUCTION MANAGER' UPON FINAL ACCEPTANCE. 23. THE ELECTRICAL CONTRACTOR SHALL LABEL ALL PANELS WITH ONLY TYPEWRITTEN DIRECTORIES. 24. IF REQUIRED, DISCONNECT SWITCHES SHALL BE H.P. RATED HEAVY-DUTY, QUICK-MAKE AND QUICK-BREAK ENCLOSURES, AS REQUIRED BY EXPOSURE TYPE. 25. ALL CONNECTIONS EXCEPT THE EV CHARGE CABLE TERMINATION IN THE CHARGE POST SHALL BE MADE WITH A PROTECTIVE COATING OF AN ANTI-OXIDE COMPOUND SUCH AS "NOALOX" BY IDEAL INDUSTRIAL INC., COAT ALL WIRE SURFACES BEFORE CONNECTING. EXPOSED ALUMINUM & COPPER SURFACES, INCLUDING GROUND BARS, SHALL BE TREATED - NO SUBSTITUTIONS. 26. ALL EXTERIOR AND INTERIOR ABOVE GROUND CONDUIT SHALL BE RIGID UNLESS SPECIFIED OTHERWISE. ALL BURIED CONDUITS SHALL BE SCH 40 PVC UNLESS SPECIFIED OTHERWISE. 27. RACEWAYS: CONDUIT SHALL BE SCHEDULE 40 PVC, MEETING OR EXCEEDING NEMA TC2 - 1990. THE CONTRACTOR SHALL PLUG AND CAP EACH END OF SPARE AND EMPTY CONDUITS AND PROVIDE TWO SEPARATE PULL STRINGS - 200 LBS TEST POLYETHYLENE CORD. ALL CONDUIT BENDS SHALL BE A MINIMUM OF 3 FT. RADIUS. RGS CONDUITS WHEN SPECIFIED, SHALL MEET UL-6 FOR GALVANIZED STEEL. ALL FITTINGS SHALL BE SUITABLE FOR USE WITH THREADED RIGID CONDUIT. COAT ALL THREADS WITH 'BRITE ZINC' OR 'GOLD GALV'. 28. SUPPORT OF ALL ELECTRICAL WORK SHALL BE AS REQUIRED BY NEC. 29. CONNECTORS FOR POWER CONDUCTORS: CONTRACTOR SHALL USE PRESSURE TYPE INSULATED TWIST-ON CONNECTORS FOR NO. 10 AWG AND SMALLER. USE SOLDERLESS MECHANICAL TERMINAL LUGS FOR NO. 8 AWG AND LARGER. 30. THE CONTRACTOR SHALL PLACE WARNING TAPE AT A DEPTH OF 12" BELOW GROUND AND DIRECTLY ABOVE ELECTRICAL SERVICE CONDUITS. CAUTION TAPE TO READ "CAUTION BURIED ELECTRIC". 31. WHEN DIRECTIONAL BORING IS REQUIRED, CONTRACTOR SHALL INSTALL A LOOSE TONING WIRE WITHIN INSTALLED CONDUIT TO ALLOW FOR IDENTIFICATION OF UNDERGROUND CONDUITS. 32. ALL BOLTS SHALL BE STAINLESS STEEL. 33. ALL MATERIALS AND EQUIPMENT SUPPLIED AND INSTALLED BY THE CONTRACTOR SHOULD BE NEW AND UNUSED. PART 1 - GENERAL CLEARING, GRUBBING, STRIPPING, EROSION CONTROL, SURVEY, LAYOUT, SUBGRADE PREPARATION AND FINISH GRADING AS REQUIRED TO COMPLETE THE PROPOSED WORK SHOWN IN THESE PLANS. 1. REFERENCES: A. LOCAL DOT TRANSPORTATION STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION (CURRENT EDITION) B. ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS). C. OSHA (OCCUPATION SAFETY AND HEALTH ADMINISTRATION). 2. INSPECTION AND TESTING: A. GENERAL CONTRACTOR SHALL PERFORM ALL WORK IN CONFORMANCE WITH THE PLANS AND SPECIFICATIONS. PERFORM INSPECTIONS BEFORE CONCEALING WORK WITH FOLLOW-ON ACTIVITIES (BACKFILL, CONCRETE POUR, ETC). 3. SITE MAINTENANCE AND PROTECTION: A. PROVIDE ALL NECESSARY JOB SITE MAINTENANCE FROM COMMENCEMENT OF WORK UNTIL COMPLETION OF THE CONTRACT. B. AVOID DAMAGE TO THE SITE AND TO EXISTING FACILITIES, STRUCTURES, TREES, AND SHRUBS DESIGNATED TO REMAIN. TAKE PROTECTIVE MEASURES TO PREVENT EXISTING FACILITIES THAT ARE NOT DESIGNATED FOR REMOVAL FROM BEING DAMAGED BY THE WORK. C. KEEP SITE FREE OF ALL PONDING WATER. D. PROVIDE EROSION CONTROL MEASURES IN ACCORDANCE WITH STATE DOT, LOCAL PERMITTING AGENCY AND EPA REQUIREMENTS. E. PROVIDE AND MAINTAIN ALL TEMPORARY FENCING, BARRICADES, WARNING SIGNALS AND SIMILAR DEVICES NECESSARY TO PROTECT AGAINST THEFT FROM PROPERTY DURING THE ENTIRE PERIOD OF CONSTRUCTION. REMOVE ALL SUCH DEVICES UPON COMPLETION OF THE WORK. F. EXISTING UTILITIES: DO NOT INTERRUPT EXISTING UTILITIES SERVING FACILITIES OCCUPIED BY THE OWNER OR OTHERS, EXCEPT WHEN PERMITTED IN WRITING BY THE CONSTRUCTION MANAGER AND THEN ONLY AFTER ACCEPTABLE TEMPORARY UTILITY SERVICES HAVE BEEN PROVIDED. G. PROVIDE A MINIMUM 48-HOUR NOTICE TO THE CONSTRUCTION MANAGER AND RECEIVE WRITTEN NOTICE TO PROCEED BEFORE INTERRUPTING ANY UTILITY SERVICE. H. SOD PLANTED IN THE FALL MUST ESTABLISH ITS ROOTS BEFORE THE FIRST WINTER FROST. DETERMINE WHEN THE FIRST FROST USUALLY OCCURS, AND PLANT THE SOD NO LATER THAN ONE MONTH BEFORE THE FIRST FROST. IF THE CONSTRUCTION IS FINISHED LATER THAN ONE MONTH BEFORE THE FIRST FROST, USE STRAW UNTIL SOD CAN BE INSTALLED. PART 2 - PRODUCTS 1. SUITABLE MATERIAL – SUITABLE MATERIAL ARE TO BE USED FOR GRADING AND BACKFILL. SUITABLE MATERIALS ARE ON SITE SOILS REMOVED FROM EXCAVATIONS THAT EXCLUDE FROZEN SOIL, ROOTS OR ORGANIC MATERIAL, DEBRIS, TRASH, REFUSE, OR PARTICLES SIZE GREATER THAN 3-INCH. SUITABLE SOILS HAVE MOISTURE CONTENTS THAT ALLOW THEM TO BE COMPACTED TO THE SAME DENSITY AS THE NATIVE SOILS. 2. UNSUITABLE MATERIAL – SOILS THAT ARE FROZEN, CONTAIN ROOTS OR ORGANIC MATERIAL, DEBRIS, TRASH, REFUSE, OR PARTICLES SIZES GREATER THAN 3-INCH. SOILS THAT ARE TOO WET OR TOO DRY TO BE COMPACTED TO THE SAME DENSITY AS THE NATIVE SOILS ARE UNSUITABLE. 3. GRANULAR BACKFILL – SHALL MEET THE FOLLOWING GRADATION 4. GRANULAR BEDDING – WELL-GRADED SAND MEETING THE GRADATION REQUIREMENT OF ASTM C 33 FINE AGGREGATE. 5. CONTROLLED LOW STRENGTH MATERIAL (CLSM)– A SELF LEVELING AND SELF COMPACTING CEMENTITIOUS MATERIAL COMPOSED OF SAND, COARSE AGGREGATE, CEMENT, FLY ASH, WATER AND ADMIXTURES. CLSM SHALL BE EXCAVATABLE AND SHALL HAVE A DESIGNED UNCONFINED COMPRESSIVE STRENGTH OF BETWEEN 50 TO 100 PSI. 6. BACKFILL – PRODUCTS MEETING THE REQUIREMENTS OF SUITABLE MATERIAL, GRANULAR BEDDING, GRANULAR BACKFILL OR CLSM. 7. TOPSOIL – SOIL WITH AN ORGANIC CONTENT SUFFICIENT TO ALLOW VEGETATIVE GROWTH. SIEVE SIZE TOTAL PERCENT PASSING 1 1/2 INCH (37.5 MM)100 NO. 4 (4.75 MM)30 TO 60 NO 200 (0.075 MM)3 TO 15 GN-2 GENERAL NOTES SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT 2 12-5-24 S&S PPK GENERAL SITE NOTES CONT.GENERAL SITE NOTES CONT. REINFORCED CONCRETE NOTES GROUNDING NOTES ANCHORAGE INSTALLATION NOTES STRUCTURAL STEEL NOTES REINFORCED CONCRETE NOTES CONT. FIBER OPTIC NOTES PART 3 - EXECUTION 1. GENERAL: A. BEFORE STARTING GENERAL SITE PREPARATION ACTIVITIES, INSTALL EROSION AND SEDIMENT CONTROL MEASURES. THE WORK AREA SHALL BE CONSTRUCTED AND MAINTAINED IN SUCH CONDITION THAT IN THE EVENT OF RAIN THE SITE WILL BE DRAINED AT ALL TIMES. B. BEFORE ALL SURVEY, LAYOUT, STAKING, AND MARKING, ESTABLISH AND MAINTAIN ALL LINES, GRADES, ELEVATIONS AND BENCHMARKS NEEDED FOR EXECUTION OF THE WORK. CONDUCT UTILITY LOCATE IN ACCORDANCE WITH THE ONE-CALL NOTIFICATION C. CLEAR AND GRUB THE AREA WITHIN THE LIMITS OF THE SITE. REMOVE TREES, BRUSH, STUMPS, RUBBISH AND OTHER DEBRIS AND VEGETATION RESTING ON OR PROTRUDING THROUGH THE SURFACE OF THE SITE AREA TO BE CLEARED. D. REMOVE THE FOLLOWING MATERIALS TO A DEPTH OF NO LESS THAN 12 INCHES BELOW THE ORIGINAL GROUND SURFACE: ROOTS, STUMPS, AND OTHER DEBRIS, BRUSH, AND REFUSE EMBEDDED IN OR PROTRUDING THROUGH THE GROUND SURFACE, RAKE, DISK OR PLOW THE AREA TO A DEPTH OF NO LESS THAN 6 INCHES, AND REMOVE TO A DEPTH OF 12 INCHES ALL ROOTS AND OTHER DEBRIS THEREBY EXPOSED. E. REMOVE TOPSOIL MATERIAL COMPLETELY FROM THE SURFACE UNTIL THE SOIL NO LONGER MEETS THE DEFINITION OF TOPSOIL. AVOID MIXING TOPSOIL WITH SUBSOIL OR OTHER UNDESIRABLE MATERIALS. SUFFICIENT TOPSOIL MAY BE STOCKPILED ON SITE FOR USE DURING FINAL SITE GRADING. F. EXCEPT WHERE EXCAVATION TO GREATER DEPTH IS INDICATED, FILL DEPRESSIONS RESULTING FROM CLEARING, GRUBBING AND DEMOLITION WORK COMPLETELY WITH SUITABLE MATERIAL. G. REMOVE FROM THE SITE AND DISPOSE IN AN AUTHORIZED LANDFILL ALL DEBRIS RESULTING FROM CLEARING AND GRUBBING OPERATIONS. BURNING WILL NOT BE PERMITTED. H. PRIOR TO EXCAVATING, THOROUGHLY EXAMINE THE AREA TO BE EXCAVATED AND/OR TRENCHED TO VERIFY THE LOCATIONS OF FEATURES INDICATED ON THE DRAWINGS AND TO ASCERTAIN THE EXISTENCE AND LOCATION OF ANY STRUCTURE, UNDERGROUND STRUCTURE, OR OTHER ITEM NOT SHOWN THAT MIGHT INTERFERE WITH THE PROPOSED CONSTRUCTION. NOTIFY THE CONSTRUCTION MANAGER OF ANY OBSTRUCTIONS THAT WILL PREVENT ACCOMPLISHMENT OF THE WORK AS INDICATED ON THE DRAWINGS. I. SEPARATE AND STOCK PILE ALL EXCAVATED MATERIALS SUITABLE FOR BACKFILL. ALL EXCESS EXCAVATED AND UNSUITABLE MATERIALS SHALL BE DISPOSED OF OFF-SITE IN A LEGAL MANNER. J. DURING EXCAVATION, THE CONTRACTOR SHALL PROVIDE SHORING, SHEETING, AND BRACING AS REQUIRED TO PREVENT CAVING OR SLOUGHING OF EXCAVATION. 2. BACKFILL: A. AS SOON AS PRACTICAL, AFTER COMPLETING CONSTRUCTION OF THE RELATED STRUCTURE, INCLUDING EXPIRATION OF THE SPECIFIED MINIMUM CURING PERIOD FOR CAST-IN-PLACE CONCRETE, BACKFILL THE EXCAVATION WITH APPROVED MATERIAL TO RESTORE THE REQUIRED FINISHED GRADE. B. PRIOR TO PLACING BACKFILL AROUND STRUCTURES, ALL FORMS SHALL BE REMOVED AND THE EXCAVATION CLEANED OF ALL TRASH, DEBRIS, AND UNSUITABLE MATERIALS. C. DO NOT PLACE FROZEN MATERIAL IN AS BACKFILL. D. PLACE BACKFILL MATERIAL OR SELECT GRANULAR BACKFILL MATERIAL WHEN REQUIRED IN UNIFORM HORIZONTAL LAYERS OF NO GREATER THAN 8-INCHES LOOSE THICKNESS AND COMPACT TO THE SAME DENSITY AS NATIVE SOIL. WHERE HAND OPERATED COMPACTORS ARE USED, THE FILL MATERIAL SHALL BE PLACED IN LIFTS NOT TO EXCEED 4 INCHES IN LOOSE DEPTH AND COMPACTED. E. WHENEVER TESTING INDICATES THAT THE CONTRACTOR HAS NOT OBTAINED THE SPECIFIED DENSITY, THE SUCCEEDING LAYER SHALL NOT BE PLACED UNTIL THE REQUIREMENTS ARE MET UNLESS OTHERWISE AUTHORIZED BY THE CONSTRUCTION MANAGER. THE CONTRACTOR SHALL TAKE WHATEVER APPROPRIATE ACTION IS NECESSARY, SUCH AS DRYING, ADDING WATER, OR INCREASING THE COMPACTIVE EFFORT TO MEET THE COMPACTION REQUIREMENTS. 3. TRENCH EXCAVATION: A. UTILITY TRENCHES SHALL BE EXCAVATED TO THE LINES AND GRADES SHOWN ON THE DRAWINGS OR AS DIRECTED BY THE GENERAL CONTRACTOR. PROVIDE SHORING, SHEETING AND BRACING AS REQUIRED TO PREVENT CAVING OR SLOUGHING OF THE TRENCH WALLS. B. EXTEND THE TRENCH WIDTH A MINIMUM OF 6 INCHES BEYOND THE OUTSIDE EDGE OF THE OUTERMOST CONDUIT. C. WHEN SOFT YIELDING, OR OTHERWISE UNSTABLE SOIL CONDITIONS ARE ENCOUNTERED, EXCAVATE THE REQUIRED TRENCH TO A DEPTH OF NO LESS THAN 12 INCHES BELOW THE REQUIRED ELEVATION, THEN BACKFILL WITH 12" OF GRANULAR BEDDING MATERIAL. 4. TRENCH BACKFILL: A. PROVIDE GRANULAR BEDDING MATERIAL OR FLOWABLE FILL IN ACCORDANCE WITH THE DRAWINGS AND THE UTILITY REQUIREMENTS. B. NOTIFY THE GENERAL CONTRACTOR 24 HOURS IN ADVANCE OF BACKFILLING. C. CONDUCT UTILITY CHECK TESTS BEFORE BACKFILLING. BACKFILL AND COMPACT TRENCH BEFORE ACCEPTANCE TESTING. D. PLACE GRANULAR TRENCH BACKFILL UNIFORMLY ON BOTH SIDES OF THE CONDUITS IN 6-INCH UNCOMPACTED LIFTS UNTIL 12 INCHES OVER THE CONDUITS. SOLIDLY RAM AND TAMP BACKFILL INTO SPACE AROUND CONDUITS. E. PROTECT CONDUIT FROM LATERAL MOVEMENT, IMPACT DAMAGE, OR UNBALANCED LOADING. F. ABOVE THE CONDUIT EMBEDMENT ZONE, PLACE AND COMPACT SATISFACTORY BACKFILL MATERIAL IN 8-INCH MAXIMUM LOOSE THICKNESS LIFTS TO RESTORE THE REQUIRED FINISHED SURFACE GRADE. G. COMPACT FINAL TRENCH BACKFILL TO A DENSITY EQUAL TO OR GREATER THAN THAT OF THE EXISTING UNDISTURBED MATERIAL IMMEDIATELY ADJACENT TO THE TRENCH. 5. FINISH GRADING: A. PERFORM ALL GRADING TO PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURES AND SMOOTH, EVEN SURFACE DRAINAGE OF THE ENTIRE AREA WITHIN THE LIMITS OF CONSTRUCTION. GRADING SHALL BE COMPATIBLE WITH ALL SURROUNDING TOPOGRAPHY AND STRUCTURES. B. UTILIZE SATISFACTORY FILL MATERIAL RESULTING FROM THE EXCAVATION WORK IN THE CONSTRUCTION OF FILLS, EMBANKMENTS AND FOR REPLACEMENT OF REMOVED UNSUITABLE MATERIALS. C. REPAIR ALL ACCESS ROADS AND SURROUNDING AREAS USED DURING THE COURSE OF THIS WORK TO THEIR ORIGINAL CONDITION. 6. ASPHALT PAVING ROAD: A. CONTRACTOR RESPONSIBLE FOR RE-STRIPING AND APPLYING SEALCOATING, UNLESS OTHERWISE NOTED. B. WASHINGTON DOT STANDARD SPECIFICATION, CURRENT EDITION. 1.DESIGN AND CONSTRUCTION OF ALL CONCRETE ELEMENTS SHALL CONFORM TO THE LATEST EDITIONS OF THE FOLLOWING APPLICABLE CODES: ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS"; ACI 318, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE". 2.DO NOT USE RETEMPERED CONCRETE, OR ADD WATER TO READY-MIX CONCRETE AT THE JOB SITE. MIX DESIGN SHALL BE APPROVED BY OWNER'S REPRESENTATIVE PRIOR TO PLACING CONCRETE. 3.ANY NEW CONCRETE NEEDED FOR THE CONSTRUCTION SHALL BE AIR-ENTRAINED AND SHALL HAVE 3000 PSI STRENGTH AT 28 DAYS. ALL CONCRETE WORK SHALL BE DONE IN ACCORDANCE WITH ACI 318 CODE REQUIREMENTS. 4.MAXIMUM AGGREGATE SIZE SHALL BE 3/4". 5.THE FOLLOWING MATERIALS SHALL BE USED: PORTLAND CEMENT:ASTM C 150, TYPE I REINFORCEMENT:ASTM A 615, GRADE 60 NORMAL WEIGHT AGGREGATE:ASTM C 33 WATER:DRINKABLE ADMIXTURES:NON-CHLORIDE CONTAINING 6.REINFORCING DETAILS SHALL BE IN ACCORDANCE WITH "DETAILING MANUAL-2004 PUBLICATION SP-66" AND "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE", ACI-318-08. 7.REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 60, DEFORMED UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185 WELDED STEEL WIRE FABRIC UNLESS NOTED OTHERWISE. SPLICES SHALL BE CLASS "B"; ALL HOOKS SHALL BE STANDARD, UNO. 7. STAGING: A. WORK / STAGING AREA TO BE CONFIRMED AT PRE-CONSTRUCTION SITE MEETING AND SURROUNDED BY TEMPORARY FENCE (SEE DETAIL BELOW) DURING CONSTRUCTION. B. POSSIBLE LOCATION FOR TEMPORARY DRIVE AISLE CLOSURE DURING CONSTRUCTION. C. CONTRACTOR TO PROVIDE TEMPORARY SIGNS TO DIRECT TRAFFIC FLOW. D. SHORT TERM FENCING TO BE PROVIDED OUTSIDE OF TEMPORARY FENCE FOR ANY OPEN TRENCHES LEFT OVER NIGHT OR UNATTENDED. E. TEMPORARY FENCE SHALL BE CLOSED AND LOCKED AT ALL TIMES. IF GATE MUST BE OPEN FOR MOVING EQUIPMENT OR MATERIALS, A SPOTTER SHALL BE PROVIDED TO TO PREVENT UNAUTHORIZED ENTRY. F. NO EQUIPMENT OR MATERIALS SHALL BE STORED OUTSIDE THE TEMPORARY FENCE FOR ANY AMOUNT OF TIME. USE CABLE WITH THE FOLLOWING MINIMUM PROPERTIES: 1. HIGH TENSILE STRENGTH >150 LB 2. TIGHT BUFFERED 3.INDOOR / OUTDOOR UV AND MOISTURE RESISTANT “RISER” CABLE 4.CONNECTOR TYPE: ST-ST 5. FIBER TYPE: MULTI-MODE 6-FIBER (3 PAIR) 62.5UM. 6 CONNECTORS ON BOTH ENDS. 6. JACKET: INDOOR/OUTDOOR RISER, BLACK 7. BREAKOUT: SIDE A: INNER END - 24 INCHES WITH 2MM FURCATION 7.A. SIDE B: OUTER END - 24 INCHES - 2MM FURCATION - STAGGERED EVERY 1" 8.WITH PULLING EYE ON SIDE B (OUTER END) AND SPOOL REEL 1. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS, UNLESS NOTED OTHERWISE: WIDE FLANGE SHAPE: A992, 50KSI ANGLE AND CHANNEL SHAPE: ASTM A36, 36 KSI PLATE: ASTM A36, 36KSI PIPE: ASTM A53 GRADE B, 35 KSI HSS: ASTM A500 GRADE B, 46KSI 2. HIGH-STRENGTH BOLTS SHALL CONFORM TO ASTM A325: ONE HIGH-STRENGTH BOLT ASSEMBLY SHALL CONSIST OF A HEAVY HEX STRUCTURAL BOLT, A HEAVY NUT, A HARDENED WASHER CONFORMING TO ASTM F436. THE HARDENED WASHER SHALL BE INSTALLED AGAINST ELEMENT TURNED IN TIGHTENING. UNLESS NOTED OTHERWISE ON THE DRAWINGS, ALL CONNECTIONS SHALL BE BEARING TYPE CONNECTIONS. 3.WELDING ELECTRODES SHALL COMPLY WITH AWS D1.1 USING A5.1 OR A5.5 E70XX AND SHALL BE COMPATIBLE WITH THE WELDING PROCESS SELECTED. WELDERS SHALL BE QUALIFIED AS PRESCRIBED IN AWS D1.1. 4. UNLESS NOTED OTHERWISE ON THE DRAWING, ALL ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 WITH HEAVY HEXAGONAL NUT. 5. FABRICATE ITEMS OF STRUCTURAL STEEL IN ACCORDANCE WITH AISC SPECIFICATION. 6. ALL EXPOSED STRUCTURAL STEEL AND BOLTS SHALL BE HOT DIP GALVANIZED PER ASTM A123. 7. SUBMIT FABRICATION AND ERECTION DRAWINGS SHOWING ALL DETAILS, CONNECTIONS, MATERIAL DESIGNATIONS, AND TOP STEEL ELEVATIONS FOR APPROVAL. THE SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL CONFORMANCE TO THE CONTRACT DRAWINGS. SUCH APPROVAL SHALL NOT RELIEVE THE FABRICATOR/CONTRACTOR OF THE RESPONSIBILITY FOR EITHER THE ACCURACY OF THE DETAILED DIMENSIONS IN THE SHOP AND ERECTION DRAWINGS OR THE GENERAL FIT-UP OF PARTS THAT ARE TO BE ASSEMBLED IN THE FIELD. 8. PRIMER SHALL BE RED OXIDE-CHROMATE PRIME COMPLYING WITH STEEL STRUCTURES PAINTING COUNCIL (SSPC) PAINT SPECIFICATION NUMBER 11 1. DRILLING THROUGH EXISTING SLAB REBAR DURING POST-INSTALLED ANCHOR BOLTS INSTALLATION IS NOT PERMITTED. 2. POST-INSTALLED ANCHOR BOLT INSTALLATION SHALL BE PERFORMED BY PERSONNEL TRAINED TO INSTALL THE SYSTEM PER THE MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS (MPII), AS INCLUDED IN THE ANCHOR PACKAGING. 3. EXPANSION AND ADHESIVE ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS USING STANDARD EMBEDMENTS AND EDGE DISTANCES UNLESS NOTED OTHERWISE ON THE DRAWINGS. 8.THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST EARTH:3 IN. CONCRETE EXPOSED TO EARTH OR WEATHER: #6 AND LARGER 2 IN. #5 AND SMALLER & WWF 1-1/2 IN. CONCRETE NOT EXPOSED TO EARTH OR SLAB AND WALL 3/4 IN. WEATHER OR NOT CAST AGAINST THE GROUND: BEAMS AND COLUMNS 1-1/2 IN. 9.A CHAMFER 3/4" SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. 10.INSTALLATION OF CONCRETE ANCHOR, SHALL BE PER MANUFACTURERS WRITTEN RECOMMENDED PROCEDURE. THE ANCHOR BOLT, DOWEL OR ROD SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR ENGINEERING APPROVAL WHEN DRILLING HOLES IN CONCRETE. 11.CURING COMPOUNDS SHALL CONFORM TO ASTM C-309. 12.ADMIXTURES SHALL CONFORM TO THE APPROPRIATE ASTM STANDARD AS REFERENCED IN ACI-301. 13.DO NOT WELD OR TACKWELD REINFORCING STEEL. 14.ALL DOWELS, ANCHOR BOLTS, EMBEDDED STEEL, ELECTRICAL CONDUITS, PIPE SLEEVES, GROUNDS AND ALL OTHER EMBEDDED ITEMS AND FORMED DETAILS SHALL BE IN PLACE BEFORE START OF CONCRETE PLACEMENT. 15.LOCATE ADDITIONAL EXPANSION JOINTS REQUIRED TO FACILITATE CONSTRUCTION AS ACCEPTABLE TO ENGINEER. PLACE REINFORCEMENT CONTINUOUSLY THROUGH JOINT. 16.REINFORCEMENT SHALL BE COLD BENT WHENEVER BENDING IS REQUIRED. 17.PLACE CONCRETE IN A UNIFORM MANNER TO PREVENT THE FORMATION OF COLD JOINTS AND OTHER PLANES OF WEAKNESS. VIBRATE THE CONCRETE TO FULLY EMBED REINFORCING. DO NOT USE VIBRATORS TO TRANSPORT CONCRETE THROUGH CHUTES OR FORMWORK. 18.DO NOT PLACE CONCRETE IN WATER, ICE, OR ON FROZEN GROUND. 19.DO NOT ALLOW CONCRETE SUBBASE TO FREEZE DURING CONCRETE CURING AND SETTING PERIOD, OR FOR A MINIMUM OF 14 DAYS AFTER PLACEMENT. 20.MAINTAIN TEMPERATURE OF CAST IN PLACE CONCRETE BETWEEN 50 DEGREES AND 90 DEGREES FA HRENHEIT. FOR COLD-WEATHER AND HOT-WEATHER CONCRETE PLACEMENT, CONFORM TO APPLICABLE ACI CODES AND RECOMMENDATIONS. IN EITHER CASE, MATERIALS CONTAINING CHLORIDE, CALCIUM, SALTS, ETC. SHALL NOT BE USED. PROTECT FRESH CONCRETE FROM WEATHER FOR 7 DAYS MINIMUM. 21.UNLESS INDICATED OTHERWISE ON THE DRAWINGS, REINFORCEMENT SPLICES SHALL MEET CLASS B, TENSION LAP REQUIREMENTS IN ACCORDANCE WITH ALL PROVISIONS OF ACI 318 LATEST EDITION, UNLESS NOTED OTHERWISE. 22.PROVIDE ACCESSORIES NECESSARY TO PROPERLY SUPPORT REINFORCING. 1. COAT ALL SURFACES WITH AN ANTI-OXIDANT COMPOUND BEFORE MATING. 2. FOR GROUND BOND TO STEEL ONLY: INSERT A CADMIUM FLAT WASHER BETWEEN LUG AND STEEL, COAT ALL SURFACES WITH AN ANTI-OXIDANT COMPOUND BEFORE MATING. 3. ENSURE THE WIRE INSULATION TERMINATION IS WITHIN 1/8" OF THE BARREL (NO SHINERS). 4. ALL BELOW GRADE BONDS TO BE EXOTHERMIC WELDS OR IRREVERSIBLE COMPRESSION-TYPE CONNECTIONS LISTED FOR USE IN THE APPLICATION WHICH THEY ARE INSTALLED. 5. ALL HARDWARE SHALL BE STAINLESS STEEL 3/8" DIAMETER OR LARGER. ALL HARDWARE 18-8 STAINLESS STEEL INCLUDING LOCK WASHERS, COAT ALL SURFACES WITH AN ANTI-OXIDANT COMPOUND BEFORE MATING. 26 N OVERALL SITE PLAN 1 A-1 22" x 34" SCALE: 1" = 20' 11" x 17" SCALE: 1" = 40' OVERALL SITE PLAN PROPOSED TRANSFORMER PROPOSED SWITCHGEAR & SUPPORT EQUIPMENT AREA NOTE: 1.EXISTING SITE PLAN DRAWING INFORMATION WAS DERIVED FROM AERIAL MAP AND SITE SKETCHES. FIELD VERIFY ALL INFORMATION PRIOR TO CONSTRUCTION. SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT 2 12-5-24 S&S PPK A-1 PROPOSED NOODOE DC150P DISPENSER (TYPICAL OF 4) M A P L E V A L L E Y H W Y RAM P T O 4 0 5 1 A-2 PROPOSED NOODOE AC7LC L2 DISPENSER MOUNTED TO NOODOE EV P200 POST ON CONCRETE FOUNDATION EXISTING SITE ACCESS 1 A-3 PROPOSED LANDSCAPING (SEE LANDSCAPE PLANS) 26 A-2 SITE PREPARATION PLAN SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT 2 12-5-24 S&S PPK NOTE: 1.EXISTING SITE PLAN DRAWING INFORMATION WAS DERIVED FROM AERIAL MAP AND SITE SKETCHES. FIELD VERIFY ALL INFORMATION PRIOR TO CONSTRUCTION. 1 A-2 22" x 34" SCALE: 3/16" = 1'-0" 11" x 17" SCALE: 3/32" = 1'-0" SITE PREPARATION PLAN TYPICAL 9'-0" X 18'-0" EXISTING LIGHT (TO REMAIN) N EXISTING PAINT STRIPE (TYP, TO REMAIN) EXISTING ASPHALT PAVING EXISTING BUILDING EXISTING CONCRETE CURB (TYP, TO REMAIN) TYPICAL 9'-0" X 18'-0" EXISTING CONCRETE CURB (TYP, TO BE REMOVED) EXISTING PAINT STRIPE (TYP, TO BE REMOVED) EXISTING LANDSCAPING (TO BE REMOVED) 20'-0" EXISTING LANDSCAPING (TO REMAIN) EXISTING LANDSCAPING (TO REMAIN)EXISTING FENCE (TO REMAIN) EXISTING ASPHALT (TYP, TO BE REMOVED) 18 ' - 0 " PROPOSED SWITCHGEAR 26 PROPOSED TRANSFORMER PROPOSED LAYOUT 1 A-3 22" x 34" SCALE: 3/16" = 1'-0" 11" x 17" SCALE: 3/32" = 1'-0" PROPOSED LAYOUT PROPOSED POST MOUNTED SIGN (TYP OF 7) NOTES: 1.EXISTING SITE PLAN DRAWING INFORMATION WAS DERIVED FROM AERIAL MAP AND SITE SKETCHES. FIELD VERIFY ALL INFORMATION PRIOR TO CONSTRUCTION. 2.CONTRACTOR SHALL PROTECT EXISTING INFRASTRUCTURE IN PLACE WITHIN THE AREA OF IMPROVEMENTS, AND RETURN SIDEWALKS, CURBING, ASPHALT, LANDSCAPING, PLANTERS, IRRIGATION SYSTEMS, AND ANY OTHER FACILITIES DISTURBED BY THE WORK TO THE SAME OR BETTER CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. 3.CONTRACTOR SHALL PROTECT EXISTING LANDSCAPING, TREES, GROUND COVER, ROOT SYSTEMS AND DECORATIVE ROCKERIES TO THE MAXIMUM EXTENT POSSIBLE. 4.CONTRACTOR TO NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO PERFORMING WORK. 5.HAND DIG AROUND EXISTING UTILITIES. CONTACT ARCHITECT/ENGINEER IF UNDERGROUND CONDITIONS CONFLICT WITH PROPOSED INSTALLATION. 6.DISTURBED AREAS AROUND TRANSFORMER AND EQUIPMENT SLAB SHALL BE COVERED WITH 3" OF MULCH AND FILTER FABRIC UNDERLAYMENT. TYPICAL 9'-0" X 18'-0" PROPOSED CONCRETE WHEEL STOP (TYP OF 9) SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT 2 12-5-24 S&S PPK A-3 EXISTING LIGHT (TO REMAIN) PROPOSED NOODOE AC7LC L2 DISPENSER MOUNTED TO NOODOE EV P200 POST ON CONCRETE FOUNDATION N PROPOSED NOODOE DC150P DISPENSER ON CONCRETE FOUNDATION W/ TYPE D BOLLARD (TYP OF 4) EXISTING PAINT STRIPE (TYP, TO REMAIN) EXISTING ASPHALT PAVING 35'-0" 9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"11'-0"5'-0"9'-0"9'-0" 88'-0" 6'-2"9'-0"8'-4"11'-6" 3' - 1 " 9'- 0 " 4'- 0 " 4' - 4 " 10'-2"5'-0" 18 ' - 0 " TY P 9'-0"18'-0"18'-0"22'-6"16'-0" EV 1 EV 2 EV 3 EV 4 EV 5 EV 6 EV 7 EV 8 EV 9 1 2 3 4 5 4'-6" TYP 4'-6" TYP 2'- 0 " TY P 4'-0 " 4'-6" TYP 4'-6" TYP 2'- 0 " TY P 3'- 2 " TY P 5'-2" TYP EXISTING BUILDING PROPOSED PARKING STRIPING PROPOSED EV PARKING STENCILEXISTING CONCRETE CURB (TYP, TO REMAIN) PROPOSED CURB (TO MATCH EXISTING) R3'-6" PROPOSED REMOVABLE UTILITY BOLLARD (SEE UTILITY SPEC, TYP OF 1) PROPOSED UTILITY BOLLARD (SEE UTILITY SPEC, TYP OF 2) PROPOSED CONCRETE SLAB PROPOSED (TYPE F) BOLLARD (TYP OF 5) TYPICAL 9'-0" X 18'-0" 5'- 4 " TY P 4' - 4 " PROPOSED GC START POINT AT EDGE OF EXISTING CURB PROPOSED 4" STRIPING W/ 45° HATCH @ 36" OC PROPOSED ACCESS AISLE PROPOSED PAINTED INTERNATIONAL SYMBOL OF ACCESS (ISA) MARKING EXISTING LANDSCAPING (TO REMAIN) EXISTING LANDSCAPING (TO REMAIN) PROPOSED LANDSCAPING (SEE LANDSCAPE PLANS) 1'- 6 " 1'-6" PROPOSED CURB (TYPE C, HEADER CURB) PROPOSED POST MOUNTED SIGN W/ ADA VAN ACCESSIBLE SIGN FOR EV7 PROPOSED UTILITY METER ON H-FRAME 2'-0" NOT TO SCALE FOR REFERENCE ONLY ADA FORWARD &SIDE REACH LIMITS 48 " M A X 15 " MI N 48 " M A X 44 " M A X >20" TO 25" MAX 48 " M A X 15 " MI N 10" MAX 48 " M A X 34 " M A X 10" MAX 46 " M A X 34 " M A X >10" TO 24" MAX GRADE DISPENSER SLAB SECTION/ELEVATION DETAIL - NOODOE DC150P #5 @ 8" OC EACH WAY TOP & BOTTOM 3/4" CHAMFER ALL SIDES MIN 12" CRUSHED ROCK FILL (SEE FROST DEPTH) SEE PLAN TOP OF ASPHALT SEE PLAN 12 " DE S I G N FR O S T D E P T H ALIGN SLAB W/ FRONT OF CURB NOTES: 1.OPERABLE PARTS OF CHARGER TO FRONT OF CURB SHALL BE 10" MAX. 2.OPERABLE PARTS OF CHARGER SHALL NOT EXCEED 54" ABOVE PARKING SURFACE WHEN CHARGER IS ON A CURB. 3.TYPE D BOLLARDS AS SHOWN IN SITE PLAN (OMITTED ON BACK SIDE IF NOT EXPOSED TO TRAFFIC). 4.CRUSHED ROCK FILL SHALL BE NON-FROST-SUSCEPTIBLE AND SHALL RANGE FROM 1/4" TO 1-1/2" SIZE (NO SAND OR FINES). SPECIFIC GRADES SATISFYING THIS CRITERIA INCLUDE AASHTO #57 AND AASHTO #67. CRUSHED ROCK SHALL BE COMPACTED TO 95%. TOP OF CURB 74 . 8 0 " 31.49"25.59" BOLLARD LOCATIONS, TYP 39 " NOTES: 1.3" RECOMMENDED MIN. FOUNDATION EXTENSIONS ALL SIDES. 6" RECOMMENDED MINIMUM DEPTH SEE PLAN TOP OF CURB 39 " 3" CLR TYP 3" CLR TYP #5 @ 8" OC EACH WAY TOP & BOTTOM MIN 12" CRUSHED ROCK FILL (SEE FROST DEPTH) (6) 1/2" SIMPSON STRONG-TIE STRONG-BOLT 2 EXPANSION ANCHORS W/ 4-3/8" MIN EMBEDMENT DISPENSER SLAB ANCHORAGE SECTION DETAIL - NOODOE DC150P 3" CLR TYP 12 " DE S I G N FR O S T D E P T H NOODOE DC150P DISPENSER ANCHORAGE AND CONDUIT DETAIL MANUFACTURER NOODOE EV OS MODEL NUMBER DC150P MAXIMUM OUTPUT POWER 150kW WEIGHT 992 LBS 3' - 2 " 5'-2" NOTES: 1.MINIMUM CONCRETE EDGE DISTANCE FOR PROPOSED ANCHORS SHALL BE 6". 2.MINIMUM CLEAR SPACING BETWEEN ANCHOR AND CONDUIT SHALL BE 3". 3.CONTRACTOR TO FIELD VERIFY THE ANCHOR SPACING PER MANUFACTURER'S INSTALLATION MANUAL. 27.17" 35.03" 18 . 5 0 " TYPE D BOLLARD QUANTITY PER PROPOSED LAYOUT PLAN FRONT 18 . 7 0 " 42.91" 29 . 5 3 " 6" TYP 6" TY P 3.94" 7.78" 13.69" 18.41" 5. 4 1 " 5.5 1 " 10 . 6 3 " 1.34" Ø (FOR ETHERNET CABLE CONDUIT) 4.02" Ø (FOR AC CABLE CONDUIT) (6) 1/2" SIMPSON STRONG-TIE STRONG-BOLT 2 EXPANSION ANCHORS W/ 4-3/8" MIN EMBEDMENT ADA DISPENSER SLAB SECTION/ELEVATION DETAIL - NOODOE DC 150P TOP OF CURB SEE PLAN MIN 12" CRUSHED ROCK FILL (SEE FROST DEPTH) #5 @ 8" OC EACH WAY TOP & BOTTOM 12 " DES I G N FR O S T D E P T H NOTES: 1.OPERABLE PARTS OF CHARGER TO FRONT OF CURB SHALL BE 10" MAX. 2.OPERABLE PARTS OF CHARGER SHALL NOT EXCEED 54" ABOVE PARKING SURFACE WHEN CHARGER IS ON A CURB. 3.TYPE D BOLLARDS AS SHOWN IN SITE PLAN (OMITTED ON BACK SIDE IF NOT EXPOSED TO TRAFFIC). 4.CRUSHED ROCK FILL SHALL BE NON-FROST-SUSCEPTIBLE AND SHALL RANGE FROM 1/4" TO 1-1/2" SIZE (NO SAND OR FINES). SPECIFIC GRADES SATISFYING THIS CRITERIA INCLUDE AASHTO #57 AND AASHTO #67. CRUSHED ROCK SHALL BE COMPACTED TO 95%. GRADETOP OF PAVEMENT SEE PLAN 74 . 8 0 " 31.49" BOLLARD LOCATIONS, TYP 39 " 25.59" NOODOE AC7LC L2 DISPENSER ANCHORAGE SECTION DETAIL 3" CLR TYP 3" CLR TYP 1'- 8 " M I N FINISHED GRADE 1" CHAMFER (TYP ALL SIDES) TOP OF FINISHED GRADE SLOPE AWAY FROM CONCRETE SURFACE SHALL RECEIVE A SMOOTH TROWEL FINISH #4 @ 10" O.C. TOP & BOT EACH WAY 4" UNDISTURBED NATURAL SUBGRADE (4) SIMPSON STRONG-TIE STRONG-BOLT 2 EXPANSION ANCHORS W/ 4-3/8" MIN EMBEDMENT (BOLT DIAMETER PER NOODOE SPECIFICATIONS) NOODOE EV P200 POST SEE PLAN 3" CLR TYP NOTES: 1.3" RECOMMENDED MIN. FOUNDATION EXTENSIONS ALL SIDES. 6" RECOMMENDED MINIMUM DEPTH D-1 CONSTRUCTION DETAILS SCALE: N.T.S. 2 D-1 4 D-1 22" x 34" SCALE: 1/2" = 1'-0" 11" x 17" SCALE: 1/4" = 1'-0" 1 D-1 22" x 34" SCALE: 1" = 1'-0" 11" x 17" SCALE: 1/2" = 1'-0" SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT 2 12-5-24 S&S PPK 6 D-1 22" x 34" SCALE: 1/2" = 1'-0" 11" x 17" SCALE: 1/4" = 1'-0" 3 D-1 22" x 34" SCALE: 1/2" = 1'-0" 11" x 17" SCALE: 1/4" = 1'-0" SCALE: N.T.S. 5 D-1 36" 12 " 2 1 / 2 " 12 " 2 1 / 2 " 12 " 17 1/2" 17"27" 71" OVERALL 41 " O V E R A L L NOTES 1.BOTTOM OF STENCIL TO BE PLACED AT THE LEADING EDGE OF THE PARKING STALL 2.STENCIL TO FIT WITHIN DIMENSIONS SHOWN 3.PAVEMENT MARKING TO BE PAINTED WHITE 4.STENCIL TO BE CENTERED LATERALLY WITHIN PARKING STALL PAINT SPECIFICATIONS 1.PAINT SHALL BE WATERBORNE OR SOLVENT BORNE, COLORS AS SHOWN OR SPECIFIED HEREIN. PAVEMENT MARKING PAINTS SHALL COMPLY WITH APPLICABLE STATE AND LOCAL LAWS ENACTED TO ENSURE COMPLIANCE WITH FEDERAL CLEAN AIR STANDARDS. PAINT MATERIALS SHALL CONFORM TO THE RESTRICTIONS OF THE LOCAL AIR POLLUTION CONTROL DISTRICT. 2.WATERBORNE PAINT: PAINTS SHALL CONFORM TO FS TT-P-1952. 3.SOLVENT BORNE PAINT: PAINT SHALL CONFORM TO FS A-A-2886 OR AASHTO M248. PAINT SHALL BE NON_BLEEDING, QUICK_DRYING, AND ALKYD PETROLEUM BASE PAINT SUITABLE FOR TRAFFIC_BEARING SURFACE AND BE MIXED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS BEFORE APPLICATION . ELECTRIC VEHICLE PAVEMENT MARKING DETAIL PAVEMENT MARKING NOTES NOTES: 1.PAINT SHALL BE WATERBORNE OR SOLVENT BORNE, COLORS AS SHOWN OR SPECIFIED HEREIN, PAVEMENT MARKING PAINTS SHALL COMPLY WITH APPLICABLE STATE AND LOCAL LAWS ENACTED TO ENSURE COMPLIANCE WITH FEDERAL CLEAN AIR STANDARDS, PAINT MATERIALS SHALL CONFORM TO THE RESTRICTIONS OF THE LOCAL AIR POLLUTION CONTROL DISTRICT. 2.WATERBORNE PAINT: PAINTS SHALL CONFORM TO FS TT-P-1952. 3.SOLVENT BORNE PAINT: PAINT SHALL CONFORM TO FS A-A-2886 OR AASHTO M248. PAINT SHALL BE NON-BLEEDING, QUICK-DRYING, AND PETROLEUM BASE PAINT SUITABLE FOR TRAFFIC-BEARING SURFACE AND BE MIXED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS BEFORE APPLICATION. 4.CONTRACTOR TO BLOCK OFF STALLS AFTER PAINTING TO ALLOW PAINT TO DRY PROPERLY WITHOUT ANY CONSTRUCTION ACTIVITIES OR PUBLIC ACCESSING THE AREA WHILE THE PAINT IS DRYING. 5.APPLY ANTI-SLIP ADDITIVE (SUCH AS SILICA) TO ALL PAINT PRIOR TO APPLICATION. PAINT GUIDELINES OVER CONCRETE: 1.WASH AND AIR BLOW CONCRETE CROWN SURFACE AREA. 2.FILL ALL CRACKS WITH CONCRETE SEALER (ALLOW DRYING PERIOD PER MFR). 3.APPLY TWO COATS OF PAINT. STRIPED ACCESS AISLE: 1.COLOR TO COMPLY WITH LOCAL STANDARDS. 2. SEE PLAN FOR LOCATION AND DIMENSION. 3.STRIPED AISLE SHALL HAVE A 4" BORDER ON BOTH SIDES. 4.STRIPED AISLE SHALL HAVE A 4" HATCH, 45° TO THE BORDER 36" OC. NOTE: 1.BOTTOM OF LOWEST SIGN SHALL BE INSTALLED 66" ABOVE GRADE. 2.ALL EA SIGNS ARE TO HAVE A WHITE RETROREFLECTIVE BACKGROUND WITH RED RETROREFLECTIVE LETTERS AND BORDER. 3.ADDITIONAL SIGNAGE APPLICABLE PER STATE OF WASHINGTON. PER RCW 3.50.100, 35.20.220, 46.16A.120 AND 46.20.270(3) 18 " T Y P 12" TYP 9 1/16" TYP 18 " T Y P EV PARKING SIGN DETAIL EV PARKING ONLY VIOLATORS SUBJECT TO CITATION & FINES OF $124 INTERNATIONAL SYMBOL OF ACCESSIBILITY DETAIL NOTES: 1.SYMBOL TO BE CENTERED ON WIDTH OF PARKING STALL. 2.BOTTOM OF SYMBOL TO BE LOCATED FLUSH WITH ACCESS DRIVE, CENTERED ON PARKING SPACE. 3.SYMBOL IS REQUIRED TO CONTRAST WITH BACKGROUND. 5-5/8" 7-3/8" 1-1/4" R10-3/4" 95° 110° 1-1/4" R2-3/8" 3'-0" 3'- 0 " 5- 5 / 8 " 2 3/8" 2 3/8" 5" 4 3 / 4 " 2 3/8" 5"3" 3 7/8" 3-1/4" 7-5/8" WHITE BORDER PAINT CONTRASTING BLUE BACKGROUND WHITE PAINT FIGURE NOTE: 1.BOTTOM OF LOWEST SIGN SHALL BE INSTALLED 66" ABOVE GRADE. 2.ALL EA SIGNS ARE TO HAVE A WHITE RETROREFLECTIVE BACKGROUND WITH RED RETROREFLECTIVE LETTERS AND BORDER, UNLESS NOTED OTHERWISE. 3.ADA SIGNS TO BE MOUNTED ABOVE ALL OTHER SIGNAGE. 4.FOR 18 " T Y P 12" TYP 6" TYP 18 " T Y P 12" TYP 9 1/16" TYP ACCESSIBLE SIGN DETAIL EV7 PAVEMENT BORDER MARKINGS DETAIL STRIPED AISLE STRIPED AISLE NOTES 1.PAINT SHALL BE WATERBORNE OR SOLVENT BORNE, COLORS AS SHOWN OR SPECIFIED HEREIN, PAVEMENT MARKING PAINTS SHALL COMPLY WITH APPLICABLE STATE AND LOCAL LAWS ENACTED TO ENSURE COMPLIANCE WITH FEDERAL CLEAN AIR STANDARDS, PAINT MATERIALS SHALL CONFORM TO THE RESTRICTIONS OF THE LOCAL AIR POLLUTION CONTROL DISTRICT. 2.WATERBORNE PAINT: PAINTS SHALL CONFORM TO FS TT-P-1952. 3.SOLVENT BORNE PAINT: PAINT SHALL CONFORM TO FS A-A-2886 OR AASHTO M248. PAINT SHALL BE NON-BLEEDING, QUICK-DRYING, AND PETROLEUM BASE PAINT SUITABLE FOR TRAFFIC-BEARING SURFACE AND BE MIXED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS BEFORE APPLICATION. 4.CONTRACTOR TO BLOCK OFF STALLS AFTER PAINTING TO ALLOW PAINT TO DRY PROPERLY WITHOUT ANY CONSTRUCTION ACTIVITIES OR PUBLIC ACCESSING THE AREA WHILE THE PAINT IS DRYING. STRIPED AISLE 1.COLOR TO COMPLY WITH LOCAL STANDARDS. 2. SEE A-3 FOR LOCATION AND DIMENSION. 3.STRIPED AISLE WILL HAVE A 4" BORDER ON BOTH SIDES 4.STRIPED AISLE WILL HAVE A 4" HATCH, 45° TO THE BORDER 36" OC. D-2 CONSTRUCTION DETAILS SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT 2 12-5-24 S&S PPK 1 D-2 22" x 34" SCALE: 1" = 1'-0" 11" x 17" SCALE: 1/2" = 1'-0" 2 D-2 22" x 34" SCALE: 1 1/2" = 1'-0" 11" x 17" SCALE: 3/4" = 1'-0" 6 D-2 22" x 34" SCALE: 1 1/2" = 1'-0" 11" x 17" SCALE: 3/4" = 1'-0" 3 D-2 22" x 34" SCALE: 1 1/2" = 1'-0" 11" x 17" SCALE: 3/4" = 1'-0" SCALE: N.T.S. 4 D-2 5 D-2 22" x 34" SCALE: 1" = 1'-0" 11" x 17" SCALE: 1/2" = 1'-0" NOTES: 1.ULTIMATE STRENGTH OF CONCRETE FOR WHEEL STOPS SHALL BE 2,500 P.S.I. @ 28 DAYS. 2.A.C. OR CONCRETE PAVING, DRILL HOLES AS REQUIRED FOR REBAR. 3.#5 REBAR x 2' - 20" LONG, DRIVE INTO COMPACTED SUBGRADE TWO PER WHEEL STOP. WHEEL STOP DETAIL 6'-0" 12" ±2" MIN 3" MAX #5 REBAR, 20" LONG (TYP 2 PER GUARD) 4" MIN 5" MAX 5" M A X R2" 1/4" PITCH OPTIONAL 10" MAX NOTES: 1.BOLLARD IS FOR WARNING PURPOSES ONLY. 2.BOLLARD DETAIL FOR BOLLARDS AROUND ELECTRIFY AMERICA EQUIPMENT. 3.CONTRACTOR TO PROVIDE (2) 6' LONG, 1/2" THICK FOAM STRIPS CROSSED OVER TOP OF STEEL PIPE TO STABILIZE SLIP COVER. 3'- 0 " 3'- 0 " 3" PROPOSED DISPENSER FOUNDATION. SEE DETAIL 2/D1 1.5" M0.39" X 0.59" SCREW (TYP OF 3) 3" SCHED 80 STEEL PIPE FILLED WITH CONCRETE STAINLESS STEEL SLIP COVER. PART #CSS4000 (PROVIDED BY OTHERS) DISPENSER BOLLARD (TYPE D) DETAIL SCREW M0.39"X0.59" 120° 6" 3'- 0 " M I N 4'- 0 " M I N 7'- 0 " CONCRETE OR ASPHALT PAVEMENT CAULK AT PERIMETER 3/8"x4" IMPREGNATED FIBERBOARD EXPANSION JOINT FILL BOLLARD WITH CONCRETE SLURRY SCHEDULE 80 STEEL PIPE TO MATCH EXISTING DIAMETER & FINISH/COLOR SCHEME 1'-6" Ø FIXED BOLLARD DETAIL (TYPE F) ROUND CONCRETE CAP CONCRETE PIER NOTES 1.WHERE THE PIPE OF THE BOLLARD IS SHOWN WITHIN THE WIDTH OF THE CURB, THE BOLLARD FOOTING SHALL BE POURED TOGETHER WITH THE CURB, WITH THE FULL PIER DIAMETER EXTENDING TO THE TOP OF CURB 7" FINISHED MATCH PAVEMENT ELEVATION R=1/4"6" 7" FINISHED GRADE R=2" R=1/4" MATCH PAVEMENT ELEVATION R=1/4" 3-#4 BARS 4"8"8" 1'-6" MIN 2'-0" MAX TYPE A CATCH GUTTER 4.5" 6" FINISHED GRADE R=2" R=1/4" PIVOT @ LIP OF CURB MATCH ADJACENT PAVEMENT 4" FINISHED GRADE SLOPE 1/2" PER FT 4" 2" 1-#4 BARS MA T C H EX I S T I N G MA T C H EX I S T I N G 1' 0 " BA C K O F CU R B BA C K O F C U R B 2" 4 1 / 2 " 8" 2" 2" 3-#4 BARS 4"8"8" 1'-6" MIN 2'-0" MAX 4" 2" TYPE B SPILL GUTTER NOTES: 1.1/2" PRE MOLDED EXPANSION JOINTS SHALL BE PLACED AT POINTS OF CURVATURE, CURB RETURNS, CURB INLETS, AND AT 250' CENTERS. CONTRACTION JOINTS SHALL BE 2" DEEP, 3/16" WIDE, AND PLACED AT 15' INTERVALS EQUALLY SPACED BETWEEN EXPANSION JOINTS. TYPE C HEADER CURB CONCRETE CURB DETAIL MATCH EXISTING MATCH EXISTING PROPOSED EXISTING MATCH PAVEMENT ELEVATION 6'- 0 " MA X 3" TYP NOTES: 1.GENERIC LOADING: V=115 MPH, EXP C, KZ=0.85, SS=3.73g, SITE CLASS=D, SDS=2.64, (2) 1-1/4" CONDUIT, METER MAX WIND AREA = 540 SQ IN. PVC CONDUIT FOR METER CAN GROUND WIRE ATTACHED TO DRIVEN GROUND ROD P1000T UNISTRUT W/ 2-1/2" STD PIPE U-BOLT (TYP)2-1/2" STD PIPE 2.88" O.D. (8) #5 REBAR EVENLY SPACED AROUND DIAMETER #3 REBAR AT 12" SPACING STANDALONE CUSTOMER PROVIDED TUV INSTRUMENT RATED METER CAN ON UNISTRUT SUPPORT 12" 3'- 0 " 3" TYP SPACED PER METER ANCHORAGE 24"Ø METER CAN BASED ON UTILITY SPECIFICATIONS UNISTRUT MUST BE ABLE TO ADJUST UP & DOWN (TYP) 2" PVC CONDUIT (TYP) (3) #3 REBAR @ 2" OC GRADE CONCRETE FOOTING (TYP) METER H-FRAME DETAIL 3'- 6 " 4' - 0 " 8"Ø 3" 3000 PSI CONCRETE FOOTING SIGNAGE POST INSTALLATION DETAIL 2" SQUARE GALV STEEL POST NOTES: 1.SEE PROPOSED LAYOUT SHEET FOR PLACEMENT. 2.BOTTOM OF LOWEST SIGN TO BE INSTALLED 66" ABOVE GRADE. 3.ADDITIONAL PARKING SIGNS TO BE INSTALLED 2" ABOVE TOP OF SIGN SPECIFIED IN NOTE #2. 4.SIGN, SIGN POST, AND SIGN FASTENERS TO BE PROVIDED BY CONTRACTOR (CONTRACTOR TO PROVIDE SIGN POST FASTENERS IF REQUIRED AND PAINTED TO MATCH). 5.IF PAINT FINISH IS DAMAGED DURING INSTALLATION, CONTRACTOR SHALL REPAINT AS REQUIRED. 6.CONTRACTOR SHALL COORDINATE WITH CITY WHEN SPECIAL JURISDICTIONAL/CITY REQUESTS ARE NECESSARY FOR ANY SIGN POST INSTALLATION, I.E. POST MATERIAL, PAINT COLORS, HARDWARE, ETC. CONTRACTOR IS RESPONSIBLE FOR ENSURING CITY APPROVES ALL MATERIALS PRIOR TO INSTALLATION. 8.CONTRACTOR TO PROVIDE AND INSTALL SIGN POST. D-3 CONSTRUCTION DETAILS SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT 2 12-5-24 S&S PPK 6 D-3 22" x 34" SCALE: 3/4" = 1'-0" 11" x 17" SCALE: 3/8" = 1'-0" 5 D-3 22" x 34" SCALE: 3/4" = 1'-0" 11" x 17" SCALE: 3/8" = 1'-0" 4 D-3 22" x 34" SCALE: 3/4" = 1'-0" 11" x 17" SCALE: 3/8" = 1'-0" SCALE: N.T.S. 3 D-3SCALE: N.T.S. 2 D-3SCALE: N.T.S. 1 D-3 NOTES: 1.SEE FLOOR PLAN IN REFERENCED SWITCHBOARD ASSEMBLY DRAWINGS FOR MOUNTING HOLE LOCATION AND SWITCHBOARD BAY DIMENSIONS. 2.SEE ELEVATION IN REFERENCED SWITCHBOARD ASSEMBLY DRAWINGS FOR BASE CHANNEL DIMENSION. 3.MINIMUM 10 1/2" CONCRETE EDGE DISTANCE REQUIRED FOR PROPOSED ANCHORAGE. 1 - TYPICAL BOTTOM VIEW LAYOUT OF (1) SWITCHBOARD BAY. SEE NOTE 1 FRONT OF SWITCHBOARD BAY PROPOSED SWITCHBOARD ASSEMBLY CABINET PROPOSED CONCRETE SLAB SE E N O T E 2 SWITCHGEAR MOUNTING DETAIL BOTTOM VIEW SECTION 1 5/8"Ø MOUNTING HOLES OFFSET 3" FROM SIDES (TYP) HEAVY DUTY NUT BELLEVILLE WASHER BASE CHANNEL (16) 1/2"Ø HILTI KWIK BOLT TZ2 SS 304/316 W/ 334" EMBEDMENT 2.94" SEE NOTE 1 SE E N O T E 1 CONCRETE EQUIPMENT SLAB DETAIL 8" REINFORCED PORTLAND CEMENT CONCRETE SLAB PAVEMENT 4x4-W4.0X4.0 WELDED WIRE MESH W/ 3" BOTTOM COVER NOTES: 1.SUBGRADE MATERIALS SHALL INCLUDE COMPACTION TO 95% OF ITS MAXIMUM DRY DENSITY. 2.CONCRETE PAVEMENT SHALL MEET THE MORE STRINGENT REQUIREMENT OF EITHER THE SPECIFICATIONS PROVIDED BY THE OWNER, LOCAL CITY/COUNTY REQUIREMENTS. 3.CONTRACTOR TO CONSTRUCT CONCRETE PAVEMENT WITH TRANSVERSE JOINTS AT 10' O.C. JOINTS TO BE CONSTRUCTED PER DETAIL ON THIS PAGE. 4.CONTRACTOR TO DOWEL AND JOINT BETWEEN CONCRETE SLAB AND CURB. 5.CONTRACTOR TO SLOPE PAD 1% TO PROVIDE POSITIVE DRAINAGE. 6.CRUSHED ROCK FILL SHALL BE NON-FROST-SUSCEPTIBLE AND SHALL RANGE FROM 1/4" TO 1-1/2" SIZE (NO SAND OR FINES). SPECIFIC GRADES SATISFYING THIS CRITERIA INCLUDE AASHTO #57 AND AASHTO #67. CRUSHED ROCK SHALL BE COMPACTED TO 95%. 3/4" CHAMFERED EDGE TOP SURFACE LAYER (SEE PLAN NOTES) CRUSHED ROCK FILL TO FROST DEPTH (6" MIN) 4" 12 " DE S I G N FR O S T D E P T H D-4 CONSTRUCTION DETAILS NOT USED SCALE: N.T.S. 6 D-4 2 D-4 22" x 34" SCALE: 1/2" = 1'-0" 11" x 17" SCALE: 1/4" = 1'-0" SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY RICHARD B. HALL STATE OF WASHINGTON 8828 REGISTERED ARCHITECT 2 12-5-24 S&S PPK 1 D-4 22" x 34" SCALE: 1" = 1'-0" 11" x 17" SCALE: 1/2" = 1'-0" NOT USED SCALE: N.T.S. 3 D-4 NOT USED SCALE: N.T.S. 4 D-4 NOT USED SCALE: N.T.S. 5 D-4 PRO P O S E D SWIT C H G E A R 26 PR O P O S E D TR A N S F O R M E R UTILITY PLAN NOTES: 1.ALL ELECTRICAL WORK AND RELATED ACTIVITIES ON-SITE SHALL BE PERFORMED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (NEC) STANDARDS AND ENFORCED BY ALL APPLICABLE JURISDICTIONAL REQUIREMENTS AT THE TIME OF CONSTRUCTION. 2.ALL ALUMINUM CONDUCTORS TO RECEIVE ANTI-OXIDATIVE COATING DURING INSTALLATION. 3.ALL PVC CONDUIT SHALL HAVE BELL-ENDS AND SEALED WITH DUCT SEAL. 4.ALL TERMINATION LUGS SHALL BE CRIMPED WITH APPROVED LUG CRIMPER WITH UL CERTIFICATION. 5.UTILITY EQUIPMENT , PREP WORK, INSTALLATION, AND SCOPE OF WORK RESPONSIBILITIES SHALL BE COORDINATED WITH UTILITY ENGINEER AT TIME OF PRECONSTRUCTION MEETING OR BEFORE THE COMMENCEMENT OF CONSTRUCTION. 6.TRANSFORMER BOLLARD PROTECTION TO BE INSTALLED PER UTILITY SPECIFICATIONS. EXACT QUANTITY, LOCATION, AND SPACING MAY BE AT THE DISCRETION OF THE UTILITY FIELD ENGINEER/INSPECTOR. 7.CONTRACTOR TO COORDINATE EXACT LOCATION OF H-FRAME MOUNTED METER WITH UTILITY COMPANY. SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY 2 12-5-24 S&S PPK E-1 N 1 E-1 22" x 34" SCALE: 1" = 20' 11" x 17" SCALE: 1" = 40' UTILITY PLAN PROPOSED TRANSFORMER PROPOSED SWITCHGEAR & SUPPORT EQUIPMENT AREA PROPOSED NOODOE DC150P DISPENSER (TYPICAL OF 4) M A P L E V A L L E Y H W Y RAM P T O 4 0 5 1 E-2 PROPOSED NOODOE AC7LC L2 DISPENSER MOUNTED TO NOODOE EV P200 POST ON CONCRETE FOUNDATION EXISTING SITE ACCESS PROPOSED LANDSCAPING (SEE LANDSCAPE PLANS) PROPOSED SWITCHGEAR 26 PROPOSED TRANSFORMER ELECTRICAL PLAN NOTES: 1.CONDUCTOR LENGTHS ARE ESTIMATES ONLY. LENGTHS ARE BASED ON DIAGRAMMATICAL MEASUREMENTS AND APPROXIMATED BURIED DEPTHS. THE EXACT ROUTING PATH AND CONDUCTOR RUN LENGTHS SHALL BE DETERMINED BY THE CONTRACTOR IN THE FIELD BASED ON PHYSICAL MEASUREMENTS. CONTRACTOR TO ORDER CONDUCTORS BASED ON FIELD MEASUREMENTS. 2.ALL ELECTRICAL WORK AND RELATED ACTIVITIES ON-SITE SHALL BE PERFORMED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (NEC) STANDARDS AND ENFORCED BY ALL APPLICABLE JURISDICTIONAL REQUIREMENTS AT THE TIME OF CONSTRUCTION. 3.ALL ALUMINUM CONDUCTORS TO RECEIVE ANTI-OXIDATIVE COATING DURING INSTALLATION. 4.ALL PVC CONDUIT SHALL HAVE BELL-ENDS AND SEALED WITH DUCT SEAL. 5.ALL TERMINATION LUGS SHALL BE CRIMPED WITH APPROVED LUG CRIMPER WITH UL CERTIFICATION. 6.UTILITY EQUIPMENT, PREP WORK, INSTALLATION, AND SCOPE OF WORK RESPONSIBILITIES SHALL BE COORDINATED WITH UTILITY ENGINEER AT TIME OF PRECONSTRUCTION MEETING OR BEFORE THE COMMENCEMENT OF CONSTRUCTION. 7.TRANSFORMER BOLLARD PROTECTION TO BE INSTALLED PER UTILITY SPECIFICATIONS. EXACT QUANTITY, LOCATION, AND SPACING MAY BE AT THE DISCRETION OF THE UTILITY FIELD ENGINEER/INSPECTOR. 8.CONTRACTOR TO COORDINATE EXACT LOCATION OF H-FRAME MOUNTED METER WITH UTILITY COMPANY. 9.LANDSCAPING NOT SHOWN FOR CLARITY. 10.REFER TO E-3 FOR CONDUIT AND WIRING SCHEDULE AS REFERENCED BY 11.CONDUIT STUBS TO BE CAPPED. 12.ALL CONDUIT STUBS FOR (FUTURE AND PROPOSED) SHALL HAVE ENOUGH SEPARATION TO INSTALL BELL ENDS ON ALL CONDUITS. # EV 6 #SHARED UP TO 350 kW CCS SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY 2 12-5-24 S&S PPK E-21 E-2 22" x 34" SCALE: 3/16" = 1'-0" 11" x 17" SCALE: 3/32" = 1'-0" ELECTRICAL PLAN TYPICAL 9'-0" X 18'-0" EXISTING LIGHT (TO REMAIN) PROPOSED NOODOE AC7LC L2 DISPENSER MOUNTED TO NOODOE EV P200 POST ON CONCRETE FOUNDATION N PROPOSED NOODOE DC150P DISPENSER ON CONCRETE FOUNDATION W/ TYPE D BOLLARD (TYP OF 4) EV 1 EV 2 EV 3 EV 4 EV 5 EV 6 EV 7 EV 8 EV 9 1 2 3 4 5 EXISTING BUILDING TYPICAL 9'-0" X 18'-0" PROPOSED UTILITY METER ON H-FRAME 1 2 3 3 ONE-LINE DIAGRAM SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY 2 12-5-24 S&S PPK E-3 7 1 2 4 3 5 6 1 E-3 SCALE: N.T.S. ONE-LINE DIAGRAM GR N D NE U T 277/480V DISTRIBUTION SECTION PROPOSED TRANSFORMER 277/480V 3ɸ, 4W PROPOSED #4/0 AWG TINNED COPPER GROUNDING ELECTRODE CONDUCTOR PER NEC 250.66(A) PROPOSED (2) 5/8"X8'-0" COPPER CLAD GROUND ROD INSTALLATION PER NEC 250.52(A)(5), 250.53(A), 250.68 16'-0" IDEAL SPACING IF SPACE IS LIMITED, THEN MEET 6'-0" MINIMUM SPACING MANUFACTURER PROVIDED BONDING JUMPER PER NEC 250.24(1)(4), 250.28(C), 250.8(A)(7) PROPOSED GROUND (PER UTILITY SPEC) MAIN BREAKER SECTIONINCOMING SECTION 1 1600AF 1600AT 3P W/ RELT 100% RATED PROPOSED 1600A SWITCHGEAR, 277/480V, 3ɸ, 4W, 65 KAIC W/ GROUND FAULT PROTECTION M 40 0 A T 40 0 A F 3P DISPENSER 1 2 DISPENSER 2 2 DISPENSER 3 2 DISPENSER 4 2 50 A 2P L2 DISPENSER 5 3 TOTAL FLA 792 LOAD SUMMARY FLA QTY TOTAL LOAD DESCRIPTION 194 4 776NOODOE DC150P DISPENSER 16 1 16NOODOE AC7LC L2 DISPENSER NOTES: 1.PROPOSED CTs/PTs SHALL BE LOCATED AS APPROVED BY UTILITY COMPANY. 2.ALL FACTORY INSTALLED BREAKER(S) FURNISHED WITH PADLOCKING DEVICE. XFMR 15kVA 480V 120/240V 1Ø 80 A 2P 40 A 2P 120/240V DISTRIBUTION SECTION, 1Ø, 3W 20 A 1P 4 GFI ON L2 DISPENSER 40 0 A T 40 0 A F 3P 40 0 A T 40 0 A F 3P 40 0 A T 40 0 A F 3P 2" MIN 3" MIN 2" MIN 3" MIN 6" MAX PAY OR NEAT LINE FOR BACKFILL PAY OR NEAT LINE FOR BACKFILL 3" MIN 6" MAX 3" MIN 6" MAX 3' MIN BETWEEN STREET INTERSECTIONS 4' MIN AT STREET INTERSECTIONS, 6' MAX20 " M I N 18 " 6" MIN 6" MAX 6" MAX BACKFILL LATERAL SERVICE AREA DETECTABLE MARKING TAPE TRACER WIRE (COMMUNICATIONS CONDUIT) ENCASEMENT AS DEFINED BY RESTORATION PLAN FINISHED GRADE OR STREET ELECTRICAL CONDUIT ELEVATION & DETAILS SCALE: N.T.S. 3 E-4 PRIMARY SERVICE TRENCH DETAIL SCALE: N.T.S. 4 E-4 SECONDARY SERVICE TRENCH DETAIL SCALE: N.T.S. 1 E-4 ELECTRICAL CONDUIT ELEVATION NOTES: 1.ELEVATION VIEW IS FOR REVIEW REFERENCE AND NOT TO BE USED FOR CONSTRUCTION. REFER TO LAYOUTS AND DETAIL SHEETS FOR CONSTRUCTION. 2.CONDUIT STUBS TO BE CAPPED. 480 V DISTRIBUTION PROPOSED SWITCHGEAR SHOWN FOR REFERENCE ONLY (SEE SHEET E-3 FOR CONFIGURATION) PROPOSED POWER UNIT 4" DEDICATED CONFIGURATION FOR CONDUIT SIZE AND QUANTITY REFERENCE ONLY. PROPOSED DISPENSER 3" DEDICATED CONFIGURATION FOR CONDUIT SIZE AND QUANTITY REFERENCE ONLY. SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY 2 12-5-24 S&S PPK E-4 120/240V DISTRIBUTION L2 DISPENSER 1" FINISH GRADE 36 " M I N 18 " 6" MIN 6" MIN BACKFILL DETECTABLE MARKING TAPE CONDUIT SHALL BE SCL-APPROVED MATERIAL SPECIFIED FOR DIRECT BURIAL PER SCL STD #0224.07 MATCH EXISTING SURFACE NOT USED SCALE: N.T.S. 2 E-4 GFI 3/4" GROUNDING DETAILS 2 E-6 SCALE: N.T.S. CADWELD CONNECTION DETAIL 3 E-6 SCALE: N.T.S. MECHANICAL CONNECTION DETAIL SCALE: N.T.S. 1 E-6 GROUNDING SCHEMATIC NOT USED SCALE: N.T.S. 4 E-6 GRND 16'-0" IDEAL SPACING PROPOSED #4/0 AWG TINNED COPPER GROUNDING ELECTRODE CONDUCTOR PER NEC 250.66(A) PROPOSED (2) 5/8"x8'-0" COPPER CLAD GROUND ROD INSTALLATION PER NEC 250.52(A)(5), 250.53(A), 250.68 IF SPACE IS LIMITED, THEN MEET 6'-0" MINIMUM SPACING NOTES: 1.ALL HARDWARE SHALL BE STAINLESS STEEL 3/8"Ø OR LARGER. ALL HARDWARE 18-8 STAINLESS STEEL INCLUDING LOCK WASHERS, COAT ALL SURFACES WITH AN ANTI-OXIDANT COMPOUND BEFORE MATING. 2.FOR GROUND BOND TO STEEL ONLY: INSERT A CADMIUM FLAT WASHER BETWEEN LUG AND STEEL, COAT ALL SURFACES WITH AN ANTI-OXIDANT COMPOUND BEFORE MATING. 3. ALL TERMINATION LUGS SHALL BE CRIMPED WITH APPROVED LUG CRIMPER WITH UL CERTIFICATION. PROPOSED DISPENSER LEGEND MECHANICAL CONNECTION CADWELD CONNECTION PROPOSED #4 AWG COPPER GROUNDING CONDUCTOR IN EACH OF (1) 3" CONDUIT PROPOSED SWITCHGEAR SHOWN FOR REFERENCE ONLY GRND GRND NE U T MAIN BREAKER PANEL SHEET TITLE JOB NAME NA-24-000834 BEST WESTERN PLUS RENTON INN 1850 MAPLE VALLEY HWY RENTON, WA 98057 EV CHARGING SOLUTIONS 11800 CLARK STREET ARCADIA, CA 91006 ap@evcs.com CHECKED BY: RBH 1 11-11-24 S&S PPK REV DATE DESCRIPTION BY 2 12-5-24 S&S PPK BURNDY CONNECTIONS (OR APPROVED EQUAL) "C" CONNECTOR HYPRESS TYPE YGHC BOND JUMPER FIELD FABRICATED GREEN STRANDED INSULATED TYPE 2-YA-2 COPPER LUGS TWO HOLE - LONG BARREL LENGTH TYPE YA-2 PARALLEL HORIZONTAL CONDUCTORS PARALLEL DEAD END TAP OR HORIZONTAL THRU CONDUCTOR TYPE PC PARALLEL HORIZONTAL CONDUCTORS PARALLEL THROUGH CONNECTION OF HORIZONTAL TYPE PT THROUGH CABLE TO GROUND ROD THROUGH CABLE TO TOP OF GROUND ROD TYPE GT HORIZONTAL SPLICE SPLICE OF HORIZONTAL CABLES HORIZONTAL STEEL SURFACE TO FLAT STEEL SURFACE OR HORIZONTAL PIPE TYPE HS VERTICAL STEEL SURFACE CABLE DOWN AT 45° TO VERTICAL STEEL SURFACE INCLUDING PIPE TYPE VS VERTICAL PIPE CABLE DOWN AT 45° TO RANGE OF VERTICAL PIPES TYPE VS CABLE TO REBAR TEE CONNECTION HORIZONTAL CABLE TAP TO VERTICAL REBAR TYPE RJ CADWELD CONNECTIONS (OR APPROVED EQUAL) E-6 GRND PROPOSED L2 DISPENSER PROPOSED #10 AWG COPPER GROUNDING CONDUCTOR IN EACH OF (1) 1" CONDUIT