Loading...
HomeMy WebLinkAboutD_Lee_Residence_Setback_Variance_250120_FinalDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Project Location Map D_Lee_Residence_Setback_Variance_250120_Final A. ADMINISTRATIVE REPORT & DECISION Decision: APPROVED APPROVED SUBJECT TO CONDITIONS DENIED Report Date: January 20, 2026 Project File Number: PR26-000010 Project Name: Lee Residence Setback Variance Land Use File Number: LUA25-000352, V-A Project Manager: Mariah Kerrihard, Associate Planner Owner: Jenny Lee, 3405 Talbot Rd S, Renton, WA 98055 Applicant/Contact: Dan Garvida, Garvida Design Group, 12613 SE 237th Pl, Kent, WA 98031 Project Location: 3405 Talbot Rd S, Renton, WA (APN 3023059020) Project Summary: The applicant is requesting approval of an Administrative Variance from the provisions of the Renton Municipal Code (RMC) regulating side yard setbacks at 3405 Talbot Rd S (APN 3023059020). The property is zoned Residential-6 (R-6), and the Comprehensive Plan land use designation is Residential Medium Density (RMD). The proposal would convert an existing nonconforming deck into conditioned living space, resulting in a reduced side-yard setback of approximately three feet ten inches (3'-10") from the new addition’s façade to the north property line. In addition, the roof eave is proposed to project an additional eight inches (8") beyond the standard twenty-four-inch (24") allowance into the required setback. Current R-6 development standards require a combined fifteen-foot (15') side-yard setback, with no less than five feet (5') on either side. There are no trees proposed to be retained on the site. Existing driveway access would be maintained. City of Renton mapping indicates the site contains regulated slopes (>15% & <=25%). Site Area: 0.24 acres Docusign Envelope ID: EC6F8E4B-7242-414D-B02E-8F9D8FFAFD66 City of Renton Department of Community & Economic Development Lee Residence Setback Variance Administrative Report & Decision LUA25-000352, V-A Report of January 20, 2026 Page 2 of 10 D_Lee_Residence_Setback_Variance_250120_Final B. EXHIBITS: Exhibit 1: Administrative Decision Exhibit 2: Site Plan Exhibit 3: Plan Set Exhibit 4: Exterior Photos Exhibit 5: Variance Request Justification Exhibit 6: King County Wastewater Treatment Division (KCWTD) Comment Letter, dated November 19, 2025 Exhibit 7: Staff Response Email to KCWTD, dated November 20, 2025 Exhibit 8: Advisory Notes C. GENERAL INFORMATION: 1. Owner(s) of Record: Jenny Lee, 3405 Talbot Rd S, Renton, WA 98055 2. Zoning Classification: Residential-6 (R-6) 3. Comprehensive Plan Land Use Designation: Residential Medium Density (RMD) 4. Existing Site Use: Detached Dwelling 5. Critical Areas: Regulated Slopes (>15% & <=25%) 6. Neighborhood Characteristics: a. North: Single-family residential, Residential Medium Density (RMD) Comprehensive Land Use Designation; Residential-6 (R-6) zone b. East: Single-family residential, Residential Medium Density (RMD) Comprehensive Land Use Designation; Residential-8 (R-8) zone c. South: Single-family residential, Residential Medium Density (RMD) Comprehensive Land Use Designation; Residential-6 (R-6) zone d. West: Single-family residential, Residential Medium Density (RMD) Comprehensive Land Use Designation; Residential-6 (R-6) zone 7. Site Area: 0.24 acres D. HISTORICAL/BACKGROUND: Action Land Use File No. Ordinance No. Date Comprehensive Plan N/A 6153 01/01/2025 Zoning N/A 6160 06/24/2025 Annexation (Highline) A-59-001 1743 04/15/1959 Docusign Envelope ID: EC6F8E4B-7242-414D-B02E-8F9D8FFAFD66 City of Renton Department of Community & Economic Development Lee Residence Setback Variance Administrative Report & Decision LUA25-000352, V-A Report of January 20, 2026 Page 3 of 10 D_Lee_Residence_Setback_Variance_250120_Final E. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE: 1. Chapter 2 Zoning Districts – Uses and Standards a. Section 4-2-020: Purpose and Intent of Zoning Districts b. Section 4-2-060: Zoning Use Table – Uses Allowed in Zoning Designations c. Section 4-2-110: Residential Development Standards d. Section 4-2-115: Residential Design and Open Space Standards 2. Chapter 3 Environmental Regulations and Overlay Districts a. Section 4-3-050: Critical Areas Regulations 3. Chapter 4 City-Wide Property Development Standards 4. Chapter 9 Permits – Specific a. Section 4-9-250: Variances, Waivers, Modifications, and Alternates 5. Chapter 11 Definitions F. FINDINGS OF FACT (FOF): 1. The Planning Division of the City of Renton accepted the above master application for review on October 16, 2025 and determined the application complete on November 13, 2025. The project complies with the 100-day review time period. 2. The Notice of Application was issued in accordance with RMC 4-8-090, Public Notice Requirements. After the land use application was deemed complete, the City mailed the Notice of Application to the applicant, property owner, and all property owners and tenants of record within 300 feet of the project site. The notice was also posted on the City’s website and on a notice board at the project site, consistent with RMC 4-8-090C. 3. The applicant’s submittal materials comply with the requirements necessary to process the administrative variance request. The applicant’s site plan, vicinity map, exterior elevations, floor plans, and exterior photos are provided as Exhibits 2-4. 4. The project site is located at 3405 Talbot Rd S, Renton, WA (APN 3023059020). 5. The project site is currently improved with a detached single-family residential dwelling. 6. Access to the site would be maintained from Talbot Rd S. The project does not propose any revisions to the access. 7. Comprehensive Plan Compliance: The property is located within the Residential Medium Density (RMD) Comprehensive Plan land use designation. The purpose of the RMD designation is to support high-quality, compact, urban development with access to urban services, transit, and infrastructure, whether through new development or through infill development. The proposal is compliant with the following Comprehensive Plan Goals and Policies is all conditions of approval are met: Compliance Comprehensive Plan Analysis ✓ Goal LU-BB: Ensure new development supports a high quality of life with design that is functional and attractive. Docusign Envelope ID: EC6F8E4B-7242-414D-B02E-8F9D8FFAFD66 City of Renton Department of Community & Economic Development Lee Residence Setback Variance Administrative Report & Decision LUA25-000352, V-A Report of January 20, 2026 Page 4 of 10 D_Lee_Residence_Setback_Variance_250120_Final ✓ Goal LU-FF: Strengthen the visual identity of Renton and its Community Planning Areas and neighborhoods through quality design and development. ✓ Policy LU-48: Consider scale and context for infill project design to preserve privacy and quality of life for residents. ✓ Policy LU-50: Respond to specific site conditions such as topography, natural features, and solar access to encourage energy savings and recognize the unique features of the site through the design of subdivisions and new buildings. 8. The site is located within the Residential-6 (R-6) zoning classification. 9. There are no trees located on-site that are subject to the City’s tree retention requirements. 10. The site is mapped with sensitive slopes. 11. Requested Variance from RMC: The following variances to (regulation[s]) have been requested by the applicant: RMC Code Citation Required Standard Requested Variance RMC 4-2-110A Development Standards for Residential Low Density and Medium Density Zones – Primary Structures Combined 15 feet (15’) with not less than five feet (5’) on either side. The applicant is requesting a three-foot ten inch (3’-10”) side-yard building setback from the north property line. RMC 4-2-110I Conditions Associated with Residential Development Standards Table (Allowed Projections into Setbacks) Eaves and cornices may project up to twenty-four inches (24") into any required setback. The applicant is requesting a two-foot four and 1/5 inch (2’-4 ⅕”) eave setback from the north property line. 12. Staff received one (1) public comment letter from King County Waste Treatment Division (KCWTD) regarding potential sewer capacity charges for any project that constructs a new connection to the sewer system, any reconnection within five (5) years of disconnection, or any change in use or building remodel that includes an increase in plumbing fixtures (Exhibit 6). Staff’s email response was provided to KCWTD’s comment letter (Exhibit 7) and the KCWTD letter was forwarded to the Engineering Division. 13. No other public or agency comments were received. 14. Representatives from various city departments have reviewed the application materials to identify and address issues raised by the proposed development. These comments are contained in the official file, and the essence of the comments has been incorporated into the appropriate sections of this report and the Departmental Recommendation at the end of this report. 15. Variance Analysis: The applicant is requesting a variance from RMC 4-2-110A to reduce the single- family structure’s minimum five-foot (5’) side yard setback to three feet ten inches (3’-10”) along the north property line (a reduction of one foot two inches [1’-2”]) to allow an expansion to the existing detached dwelling above the existing foundation. Furthermore, the applicant is requesting that the roof eaves of the addition be allowed to extend to within two feet four and one-fifth inches (2’-4 ⅕”) Docusign Envelope ID: EC6F8E4B-7242-414D-B02E-8F9D8FFAFD66 City of Renton Department of Community & Economic Development Lee Residence Setback Variance Administrative Report & Decision LUA25-000352, V-A Report of January 20, 2026 Page 5 of 10 D_Lee_Residence_Setback_Variance_250120_Final of the north property line, representing a reduction of seven and four-fifths inches (0'-7 ⅘”) from the side yard setback requirement. The proposal is subject to the following variance criteria, pursuant to RMC 4-9-250B.6. Therefore, staff recommends approval of the requested variance. Compliance Variance Criteria and Analysis ✓ a. That the applicant suffers practical difficulties and unnecessary hardship and the variance is necessary because of special circumstances applicable to subject property, including size, shape, topography, location or surroundings of the subject property, and the strict application of the Zoning Code is found to deprive subject property owner of rights and privileges enjoyed by other property owners in the vicinity and under identical zone classification. Staff Comment: The existing lot is 10,454 square feet (0.24 acres) and is located on Talbot Rd S. The irregular, quadrilateral-shaped property is approximately 77 feet (77’) wide from north to south, and approximately 129 feet (129’) deep from east to west on the northern side of the property, and approximately 137 feet (137’) deep from east to west on the southern side of the property. The property is a previously developed single-family lot with a two-story single-family dwelling with a daylight basement and a main floor, originally built in 1955, and includes an attached deck above the finished basement on the north side of the home. The submitted Site Plan (Exhibit 2) shows the northwest corner of the deck at approximately four feet four inches (4’-4”) from the north property line and the northeast corner of the deck at approximately three feet ten inches (3’-10”) from the same property line. According to the applicant, an addition was permitted in 2006 (B060316) that expanded the main floor by 103 square feet. An asphalt driveway of approximately 2,936 square feet connects the basement-level off-street parking area to the public street (Talbot Rd S). The existing residence has the front door oriented east towards Talbot Rd S with the proposal of an additional front door included in the proposed building addition (B24002305). The north property line abuts a 6.47-acre pipestem lot owned by the city (APN 3023059062). The abutting parcel to the north is zoned Residential-1 (R- 1), includes several critical areas that are more than 300 feet (300’) from the proposed development, and is identified by the applicant as unbuildable, resulting in a side-yard interface with no present or likely future residential structure and limited potential for typical side yard conflicts. Staff has reviewed the proposal and finds that the requested side yard setback reduction does not disrupt a transition between active residential intensities and remains consistent with the purpose of the R-6 standards, which support single- family development and allow middle housing where land is suitable for infill and larger lot development at a moderate density. The request is also compatible with the Residential Medium Density (RMD) designation, which supports high-quality, compact urban development with access to urban services, transit, and infrastructure, whether through new development or through infill development. In addition, staff finds that the applicant suffers from practical difficulties, unnecessary hardship, and special circumstances due to the modest, previously permitted building foundation that extends into the side-yard setback. Strict application of the required five-foot (5’) side-yard setback would necessitate costly demolition or reconstruction of the existing finished basement to meet with the current R-6 standard. Moreover, such application would deprive the owner of a Docusign Envelope ID: EC6F8E4B-7242-414D-B02E-8F9D8FFAFD66 City of Renton Department of Community & Economic Development Lee Residence Setback Variance Administrative Report & Decision LUA25-000352, V-A Report of January 20, 2026 Page 6 of 10 D_Lee_Residence_Setback_Variance_250120_Final reasonable opportunity to convert the existing deck to living space within the established building envelope. ✓ b. That the granting of the variance will not be materially detrimental to the public welfare or injurious to the property or improvements in the vicinity and zone in which subject property is situated. Staff Comment: The applicant contends that the granting of the variance would not be materially detrimental to the public welfare or injurious to the property or improvements in the vicinity or zone. The variance would allow the existing nonconforming side yard condition to remain and permit a conversion of the existing deck to habitable living space within the same approximate footprint. The applicant contends that the affected side yard abuts a city-owned parcel to the north as shown in the Exterior Photos (Exhibit 4). According to the applicant, the nearest developed residential structure to the north is about 280 feet (280’) away, which reduces the likelihood of immediate visual or privacy impacts identified in the applicant’s justification. Given the separation to the nearest residence and the presence of an intervening, vegetated City parcel, the reduced north side yard does not create the type of privacy, noise, or visual intrusion impacts that the R-6 side yard setbacks are intended to avoid between typical residential zones and uses. Staff has reviewed the requested variance and finds that the proposal would formalize the structure’s existing nonconformance with the existing R-6 setback standards by allowing the reduced separation to be carried forward for the life of the structure that abuts the city-owned parcel located to the north. According to the applicant, on March 8, 2024, a Notice of Violation and Order to Correct, Code Case No. CODE23-000071, was issued regarding the enclosure to the existing deck without a building permit (Exhibit 5). The variance retains a physical separation between the dwelling and the north property line, and any building permit would be required to demonstrate compliance with current Building and Fire Code requirements for wall ratings, openings, and eave projections at the reduced setback, ensuring that fire protection and emergency access objectives of the side-yard standard are maintained. Compliance with Building and Fire Code separation and opening limitations at a reduced setback would be evaluated as part of the building permit review. As noted in the comments from Development Services in the Advisory Notes (Exhibit 8), structures located less than five feet (5') from the property line are subject to fire-resistance-rated construction requirements pursuant to the 2021 International Residential Code (IRC), Table R302.1(1). Building and fire codes operate independently from the land use variance criteria and do not substitute for a clear land use finding that there is no material detriment. Therefore, staff can conclude that the criterion can be met through continued review and compliance with applicable building, fire, and critical area requirements. Staff finds the combined side yards on the lot continue to exceed the minimum total width required by RMC 4-2-110A (combined 15 feet [15’] with not less than 5 feet [5’] on either side – approximately 18 feet 7 inches [18’-7”] provided), and the abutting tract remains largely open and vegetated, so the variance does not materially diminish light, air, or usable open space on this or adjoining residential properties. Due to the abutting city-owned parcel being heavily vegetated and the nearest developed residence to the north is located several hundred feet away, the reduced north side-yard does not introduce the close window-to-window Docusign Envelope ID: EC6F8E4B-7242-414D-B02E-8F9D8FFAFD66 City of Renton Department of Community & Economic Development Lee Residence Setback Variance Administrative Report & Decision LUA25-000352, V-A Report of January 20, 2026 Page 7 of 10 D_Lee_Residence_Setback_Variance_250120_Final relationships, noise conflicts, or visual intrusion that side-yard setbacks are intended to prevent between neighboring homes, and overall privacy and livability are preserved. Staff has reviewed the applicant’s justifications and concurs with their analysis and finds that the proposed variance would not be detrimental to the public welfare or injurious to the property or improvements in the vicinity and zone in which the subject property is situated based on the site and neighborhood characteristics. The granting of the variance would not have a negative visual impact on the surrounding property owners due to the design proposed and location. ✓ c. That approval shall not constitute a grant of special privilege inconsistent with the limitation upon uses of other properties in the vicinity and zone in which the subject property is situated. Staff Comment: The applicant contends that the combined side yard setbacks exceed the required side yard setback standard and that the requested variance is limited to recognizing an encroachment on the north side of the lot while leaving all other development standards, including lot coverage, impervious surface, and height, compliant with the R-6 standards. The north side of the single-family dwelling faces a heavily vegetated, city‑owned parcel that functions as a de facto buffer to the proposed addition. The nearest developed residential structure to the north is approximately 280 feet (280’) away, so the proposed 14 inches of reduced side yard would not create typical light, air, or privacy impacts to an adjacent home. As shown in the Plan Set (Exhibit 3), the primary dwelling maintains its orientation to Talbot Rd S, and no change is proposed to front-yard placement or overall building height; as a result, staff finds the variance does not alter the established streetscape or undermine the intent of the R-6 standards and Residential Medium Density designation to produce stable, medium-density residential neighborhoods. Similarly situated R-6 lots could seek comparable relief where long-standing structural encroachments are documented and overall development remains within the R-6 envelope. Approval of this variance does not confer a development intensity or use that would be unavailable to other properties in the vicinity or within the same zone. Design review for the building permit would also apply the City’s residential design and open space standards to the addition, ensuring that materials, façade composition, and architectural features remain compatible with surrounding development. Compliant if Condition of Approval is Met d. That the approval is a minimum variance that will accomplish the desired purpose. Staff Comment: The applicant contends that the requested variance would retain the existing single-family residential use, which is typical for the R-6 zone and Residential Medium Density designation, and would not add height, floor area beyond the existing deck footprint, or any new use beyond conversion of the deck to living space as shown in the Plan Set (Exhibit 3). The applicant further maintains that the combined side yard setbacks on the property are approximately eighteen feet seven inches (18’-7"), exceeding the required fifteen-foot (15') minimum, and that both lot coverage and impervious surface remain below the maximum standards. As a result, the site continues to comply with the development standards anticipated by the code even with a reduced north side yard. The variance request is tailored to the surveyed location of the existing basement wall Docusign Envelope ID: EC6F8E4B-7242-414D-B02E-8F9D8FFAFD66 City of Renton Department of Community & Economic Development Lee Residence Setback Variance Administrative Report & Decision LUA25-000352, V-A Report of January 20, 2026 Page 8 of 10 D_Lee_Residence_Setback_Variance_250120_Final and deck rather than authorizing new encroachment farther into the setback. Other older single‑family lots in established neighborhoods may present similar conditions, and granting relief to regularize this specific, documented encroachment would not create a level of development intensity or use that is unavailable to other properties with comparable circumstances. Staff has reviewed the applicant’s justification and concurs that approval of the requested variance, limited to the existing building footprint and roof overhang, would not constitute a grant of special privilege inconsistent with the limitations upon uses of other properties in the vicinity and zone. The request allows the site to develop in an orderly manner with a coherent building design, while still implementing the intended development pattern for medium density residential zones. Therefore, staff recommends as a condition of approval, that the side-yard setback reduction authorized by this variance at one foot two inches (1’-2”) would apply only to the existing finished basement building envelope and the modest addition above it. In addition, roof eaves, bay elements, and other projections may not extend more than eighteen inches (18”) beyond the existing building envelope toward the north property line. G. CONCLUSIONS: 1. The subject site is located in the Residential Medium Density (RMD) Comprehensive Plan designation and complies with the goals and policies established with this designation, see FOF 7. 2. The subject site is located at 3405 Talbot Rd S, Renton, WA (APN 3023059020) and is in the Residential-6 (R-6) zoning designation and complies with the zoning and development standards established with this designation provided the applicant complies with City Code and conditions of approval, see FOF 4 and FOF 8. 3. The requested variance meets the four (4) criteria to be considered in making a decision on a variance request as established by City Code, provided the project complies with all advisory notes and conditions of approval contained herein. The analysis of the proposal according to variance criteria is found in the body of the Staff Report, see FOF 15. 4. Key characteristics of the project include converting an existing nonconforming deck above a finished basement on the north side of the home into conditioned living space, resulting in a reduced side-yard setback on the north side of the property. The proposal would reduce the side-yard setback by approximately one-foot two inches (1’-2”). H. DECISION: The Lee Residence Setback Variance, File No. LUA25-000352, V-A, as depicted in Exhibits 2 and 3, is approved and is subject to the following condition: 1. The side-yard setback reduction of one foot two inches (1’-2”) shall apply only to the existing finished basement building envelope and the modest addition above it. In addition, roof eaves, bay elements, and other projections may not extend more than eighteen inches (18”) beyond the existing building envelope toward the north property line. Docusign Envelope ID: EC6F8E4B-7242-414D-B02E-8F9D8FFAFD66 City of Renton Department of Community & Economic Development Lee Residence Setback Variance Administrative Report & Decision LUA25-000352, V-A Report of January 20, 2026 Page 9 of 10 D_Lee_Residence_Setback_Variance_250120_Final DATE OF DECISION ON LAND USE ACTION: SIGNATURE: Matthew Herrera, Planning Director Date TRANSMITTED on January 20, 2026 to the Owner/Applicant/Contact: Owner: Applicant/Contact: Jenny Lee 3405 Talbot Rd S Renton, WA 98055 Dan Garvida 12613 SE 237th Pl Kent, WA 98031 TRANSMITTED on January 20, 2026 to the Parties of Record: Emmeline Aquino King County Wastewater Treatment Department 201 S Jackson St, KSC-NR-0503 Seattle, WA 98104 TRANSMITTED on January 20, 2026 to the following: Gina Estep, CED Administrator Justin Johnson, Development Engineering Director Nathan Janders, Development Engineering Manager Stephanie Rary, Property Services Specialist Clark H. Close, Current Planning Manager Anjela Barton, Fire Marshal I. LAND USE ACTION APPEALS, REQUEST FOR RECONSIDERATION, & EXPIRATION: The administrative land use decision will become final if the decision is not appealed within 14 days of the decision date. APPEAL: This administrative land use decision will become final if not appealed in writing to the Hearing Examiner on or before 5:00 PM on February 3, 2026. An appeal of the decision must be filed within the 14-day appeal period (RCW 43.21.C.075(3); WAC 197-11-680). Appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov or delivered to City Hall 1st floor Lobby Hub Monday through Friday. The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date if your appeal is submitted electronically. The appeal submitted in person may be paid on the first floor in our Finance Department. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov. EXPIRATION: The Variance decision will expire two (2) years from the date of decision. A single one (1) year extension may be requested pursuant to RMC 4-9-250. RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be reopened by the approval body. The approval body may modify his decision if material evidence not readily Docusign Envelope ID: EC6F8E4B-7242-414D-B02E-8F9D8FFAFD66 1/20/2026 | 4:32 PM PST City of Renton Department of Community & Economic Development Lee Residence Setback Variance Administrative Report & Decision LUA25-000352, V-A Report of January 20, 2026 Page 10 of 10 D_Lee_Residence_Setback_Variance_250120_Final discoverable prior to the original decision is found or if he finds there was misrepresentation of fact. After review of the reconsideration request, if the approval body finds sufficient evidence to amend the original decision, there will be no further extension of the appeal period. Any person wishing to take further action must file a formal appeal within the 14-day appeal time frame. THE APPEARANCE OF FAIRNESS DOCTRINE: provides that no ex parte (private one-on-one) communications may occur concerning the land use decision. The Doctrine applies not only to the initial decision, but to Appeals to the Hearing Examiner as well. All communications after the decision/approval date must be made in writing through the Hearing Examiner. All communications are public record and this permits all interested parties to know the contents of the communication and would allow them to openly rebut the evidence in writing. Any violation of this doctrine could result in the invalidation of the appeal by the Court. Docusign Envelope ID: EC6F8E4B-7242-414D-B02E-8F9D8FFAFD66 CITY OF RENTON DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT ADMINISTRATIVE REPORT & DECISION EXHIBITS Project Name: Lee Residence Setback Variance Land Use File Number: LUA25-000352, V-A Date of Report January 20, 2026 Staff Contact Mariah Kerrihard Associate Planner Project Contact/Applicant Error! Reference source not found. Garvida Design Group 12613 SE 237th Pl, Kent, WA 98031 Project Location 3405 Talbot Rd S, Renton, WA (APN 3023059020) The following exhibits are included with the Administrative report: Exhibit 1: Administrative Decision Exhibit 2: Site Plan Exhibit 3: Plan Set Exhibit 4: Exterior Photos Exhibit 5: Variance Request Justification Exhibit 6: King County Wastewater Treatment Division (KCWTD) Public Comment Letter, dated November 19, 2025 Exhibit 7: Staff Response Email to KCWTD, dated November 20, 2025 Exhibit 8: Advisory Notes Docusign Envelope ID: EC6F8E4B-7242-414D-B02E-8F9D8FFAFD66