Loading...
HomeMy WebLinkAboutW-438401N RYDER TUKWILA LC0549 RYDER SYSTEM, INC 11690 NW 105 STREET MIAMI, FLORIDA 33178 PHONE: (305) 500-5076 WATER LINE RELOCATION OWNER'S INTENDED USES TO CONSTRUCT OFFICES AND A FACILITY FOR THE RENTING, LEASING, MAINTENANCE, FUELING, SALES, WASHING, AND PARKING OF VEHICLES. PROJECT VARIABLES CIVIL ENGINEERING: INFINITY ENGINEERING GROUP LLC. CIVIL ENGINEERS PHONE: 813-434-4770 GEO-TECHNICAL REPORT: NIA GEO-TECHNICAL PHONE: NIA HEATING DEGREE DAYS: ---- SURVEYOR'S NAME: BBA LAND SURVEYING SURVEYORS TELEPHONE: 206-406-1257 WATER MAIN LINE 12" D.I. WATER MAIN LINE SCOPE OF WORK NOTES 1. PERFORM ALL WORK IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL CODES (INCLUDING - BUT NOT LIMITED TO - FIRE RESISTANCE RATED CONSTRUCTION & OPENING ASSEMBLIES, ACCESSIBILITY COMPLIANCE, SMOKE DETECTION & THE LIKE) AS WELL AS WITH OWNER -FURNISHED CRITERIA, PLANS, AND SPECIFICATIONS; IF THERE IS A CONFLICT AMONG VARIOUS BID REFERENCES, PLANS, SPECIFICATIONS OR CODES, THE STRICTEST STANDARDS SHALL APPLY AND BE INCLUDED IN THE BID. 2- DESIGNIBUILD CONTRACTOR SHALL CONSTRUCT A NEW FACILITY AS INDICATED ON CRITERIA DRAWINGS, COMPLETE AND OPERATIONAL. COORDINATE FULLY WITH OTHER CONTRACTORS AT THE SITE. 3. SUCCESSFUL BIDDER SHALL UNDERTAKE TO PERFORM THE WORK ON A DESIGN/BUILD BASIS, AND IS RESPONSIBLE FOR ALL ENGINEERING, ARCHITECTURAL DESIGN, CONSTRUCTION DRAWINGS, PERMITS., AND TESTING. 4. REVIEW ATTACHED BOUNDARY AND TOPOGRAPHICAL SURVEY. 5. DESIGNIBUILID CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A PROPOSAL AND CHECK THE AREA OF WORK AND VERIFY LOCATIONS OF UTILITIES AND POINTS OF OF CONNECTION AND INCLUDE IN THE BID ALL REQUIRED, OFF -SITE INSTALLATIONS, 63 7, DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH ALL STORM WATER PERMIT REQUIREMENTS REGULATING CONSTRUCTION SITE RUN OFF, AND EROSION AND SEDIMENT RUN OFF AND CONTROL AND SHALL INCLUDE IN HIS BASE BID ALL REQUIREMENTS FOR STORM WATER MANAGEMENT AND CONTROL, THAT IS, STRUCTURES, PIPES, HEADWALLS AND THE LIKE, AS INDICATED ON CIVIL/SITE DRAWINGS. 17850 WEST VALLEY HWY TUKWILA, WA 98188 SCOPE OF WORK NOTES (CONT pillim.-I V2 -q1111_ir .} lama i _ E• SCOPE OF WORK NOTES (CONT 21. PRIOR TO RECEIVING APPROVAL OF FINAL PROGRESS PAYMENT, PUNCH LIST WORK MUST BE COMPLETED AND VERIFIED BY OWNER'S FACILITY PERSONNEL OR PROJECT ENGINEER, AND DESIGNIBUILD CONTRACTOR SHALL PROVIDE TWO SETS OF THE FOLLOWING ITEMS TO OWNER'S PROJECT ENGINEER: EQUi r1MENT I► SThI ATIE)N P PERATIE)N AN M IR ITENANGE I AKIN IAI S -COPY OF BUILDING PERMIT(S). -COPY OF CERTIFICATE OF OCCUPANCY AND DOCUMENTATION FROM ALL AHTS SHOWING ALL PERMITS HAVE BEEN CLOSED OUT. -WARRANTEE LETTER FROM DESIGNIBUILD CONTRACTOR TO OWNER INDICATING WORK IS GUARANTEED FOR A PERIOD OF TWO YEARS FROM THE DATE OF ACCEPTANCE. COORDINATION NOTES WORK BY OTHERS: • ALL SIGNAGE WILL BE BY OTHERS, EXCEPT FOR POWER FEEDS. BUILDING CODES • BUILDING CODE: 2021 WASHINGTON STATE BUILDING CODE • MECHANICAL CODE: 2021 WASHINGTON STATE MECHANICAL CODE • PLUMBING CODE; 2021 WASHINGTON STATE PLUMBING CODE -ANY CITY, STATE, FEDERAL AGENCY DOCUMENTATION INDICATING THAT ELECTRICAL CODE: INSPECTIONS HAVE BEEN MADE AND WRITTEN APPROVALS HAVE BEEN 2023 NATIONAL ELECTRICAL CODE GRANTED. -ACCEPTED AIR BALANCING REPORT FROM INDEPENDENT AIR BALANCE • FIRE CODE: COMPANY -TEST RESULTS (COMPACTION, PAVING, FLOOR SLABS, AND 2021 WASHINGTON STATE FIRE CODE THE LIKE) Ge AP-11 ETEE) TANK N MANUFACTURER'S NL FACTI IP ER'S INSTALLATION 1 ATION CHECK LIST. i iNDER Re ND PETRe E IRA Hint -A CERTIFICATE THAT HYDROSTATIC TEST WERE PERFORMED PER MANUFACTURER'S INSTRUCTIONS ON THE TURBINE ENCLOSURE, SPILL BUCKETS AND DISPENSER BOXES, AND ALL PENETRATIONS, SEAMS, & JOINTS ARE WATER TIGHT. -RECORD DRAWINGS ON C!D IN AUTOCAD FORMAT RELEASE 14 OR HIGHER. WHOM "WHOBilli :• - !- I> u 0 E 2 C C ® G-1 TITLE SHEET G-2 CIVIL SPECIFICATIONS 1 of 2 ALTA I ACSM SURVEY BY OTHERS 2 of 2 ALTA f ACSM SURVEY BY OTHERS r ® SP-1 OVERALL SITE PLAN SP-2 DEMOLITION PLAN SP-2.1 DEMOLITION PLAN = P-3 UTILITY SITE PLAN a a ® SP-3.1 UTILITY SITE PLAN ■ SP-4 GRADING PLAN CS-1 CIVIL SITE DETAILS DT-1 DETAILS ® DT-2 DETAILS PP-1 PLAN AND PROFILE THIS PLANSEf WAS REVIEWED BY CITY OF RENTON FOR THE INSTALLATION OF A WATERMAIN EROSION CONTROL MEASURES SHALL BE REVIEWED AND APPROVED BY CITY OF TUKWILA REGIONAL FIRE AUTHORITY Mr8* APPROVED cthomas 01113f2026 �lalr WATER UTILITY DEVELOPMENT ENGINEERING ABDOUL GAFOUR 0111312026 H Bray 01 /13/2026 W-438401 11 co C) Cf co Jw ❑ =00 > W CO ct CIO uj �J Lu r Lij LLI 2 w Ty 1NFINITY ENGINEERING CROUP, LLC 1208 East Kcnncdy 13onlcr-ard Suitc 230 Tampa, Florida 33602 [P 1: 813.131.4770 [f]; 813.445.4211 W %-w.icproup.nct CW. of Auth. No. 603-536-314 O Z LO O 04 O RICHARD HERNANDEZ, P.E. WA PEG. NO. 50841 Digitally Signed Richard Hemanc HE" DM c=US, c w� "y + serialNumber=A goo 240410344595, y cn=Richard Herr email=richard@i 50941 net 4ss or` Date: 2025.12.11 Q9:11:51-Q6'00' Adobe Acrobat N DatL:2o17.012,30262 G- M� W Nt CD 'CD u J N , u x