Loading...
HomeMy WebLinkAboutW-438406N 1• i Nn1 — Wm. � wrn wr71 - X X � Wrn IINE(DY NG) 12" INE( �I G) $" PIN (DYI G) v - TR . E q W X } DES : `n ' - EXISTING FIRE HYDRANT TO REMAIN v ENTF;t N 0 ENTRY IE(E)=25.94' 4"PVC k san b o a PLACEMENT IS MANHOL d .. SYMBOLS LEGEND PROPERTY LINE c _ 2 � EXISTING, CONCRETE TO REMAIN N — 88"22`12" W 362.14' (362.36- DEED) a m E All, x x x �+ s° x I EXISTING TO REMAIN J ?51 4 x m 12" E o " PI E _$,r — E l q,r PINE - 6.0 �I { EXISTING PARKING STRIAE TO REMAIN Q " � ,„' °` — ~ ` — — a�� PIE Iry _ o n PINS o T0„ PI P Q 2 - -{/ E$ +0 ;IJ,� ^E 6 PI E f _ EXISTING ASPHALT To BE SAWCUT AND REMOVED ,LO CA P} +2 2 1101 E {{---- -- _ $ CA — _ - — — ---- --- ----- -- — ----- -- ,-----------L-- — — — — ——--------- �. EXISTING TO BE REMOVED o EXISTING I2"GVINMH � 1 rl PINES 2 •1 {{---- —" 20. SET AS 5TA 00+00 Wm EXISTING WATER MAIN TO BE ABANDONED IN PLACE r Y— — — — — — —ue — s cli ue ue ue :r ` ue — — — — — — — — — — ` 28 a� y rY EXISTING 15' UTILITY EASEMENT TO BE RELOCATED ' - 26, l l ABBREVIATION$: w IE(W)=25.96' � l AST ABOVEGROUND STORAGE TANK 4' PVC DEF DIESEL EXHAUST FLUID r e cr v. IFI; WALL FIE FDW IRE LE EXTINGUISHER EXISTING 12" WATER 12"CMP�NDERWATFMAX MAXIMUM (N EXISTING 1" POI+VER LINE �, nm° ' MIN MINIMUM MAIN TO REMAIN BURIEQ 24" BEL01+11 GRADE '' e— — —�—e `� O.C. ON CENTER + ° -0 TYP TYPICAL UNDERGROUNDSTORAGE TANK WC, ¢ 11 FT VERIFY FIELD tip• - o - ,9. '} a NOTE- (M1' � 5 3'-0I' L'-11" �0 I I �;i'• CONTRACTOR TO FIELD VERIFY DEMO AREA AND BID ACCORDINGLY 41- fil 5i-0" 8 b b -- O Q '� + DEMOLITION NOTES. �� + + + P ' . I- THE CONTRACTOR SHALL COORDINATE THE REMOVAL OF EXISTING UTILITIES WITH THE }rye in \ a Q OWNER OF SAID UTILITY- THIS SHALL INCLUDE BUT NOT BE LIMITED TO WATER, SEWER, GAS, CABLE TV, POWER AND TELEPHONE- +25,55 - tnz +- — —pTv �' 2, THE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES PRIOR TO DEMOLITION AND + d d WILL BE RESPONSIBLE FOR THE DAMAGE OF ANY ON -SITE OR OFF -SITE UTILITIES THAT EXISTING 12 WATERMAIN PORTION TO BE REMOVED �. AS SHOWN IN TRENCH >` 00 ENTRY EN I-�(Y ry � ti �n 1 � BUILDING MATCH LINE A -A' ENTRY ENTRY I EXISTING 15 -fl UTILITY EASEMENT TO BE RELOCATED TO NEW WATER MAIN EXISTING 12" WATER MAIN �q : TO BE ABANDONED IN PLACE lep , ,9z- EXISTING 8" SANITARY LINE TO REMAIN n1 d 1 PROPOSED PRODUCT PIPING LINE AND ELECTRICAL CONDUITS — SUBMITTED BY SEPARATE PERMIT 0 as1 ASPHALT TO BE REMOVED p4 EN 'TY co !*.4 b O hh co dm � ti ay d co Lu I d m g ° d64+uu �.4 I A EXISTING 6" SANITARY LINE TO REMAIN �. d L a e 3 � I d san san + R d + art $ ` asan kvk. � ' d c 78 T 27. �\ r _ A I o r BUILDING HT=23.7' •� d I OFFIFF i I ay q EXISTING 15'-0" UTILITY EASEMENT TO E� BE RELOCATED TO NEW WATER MAIN 8g'LZ-B - EXISTING 12" WATER MAIN TO BE ABANDONED IN PLACE u I s$ p Ad 4 4 a d �y 4 I ENLRY LL MATCH LINE A -A' ARE NOT A PART OF THIS PROJECT OR ARE NOT IDENTIFIED TO BE REMOVED. PAVEMENT NOT REVIEWED BY CITY OF RENTON WATER UTILITYO DEVELOPMENT ENGINEERING ABDOUL GAFOUR 01l112026 H Bray 01 / 13/2026 DEMOLITION PLAN I LO C) Z Jw=co < 00 J J 00 11 Lu J 00 ~ LU W0r � N Q C0 O LO N U 1,iFINITY ENGINEERIItiG CROUP, LLC 1208 East Kcnncdy Butilcr-ard Suitc 230 Tampa, Florida 33602 [p 1: 813.131.4770 If]; 813.445.4211 W %-w.icproup.nct Cert. of Auth. No. 603-536-314 O Z LO CL 0 o I d m CD � Y d3 a RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 Dig itallysignedby 'chard Hernandez iQ DN: c=US, serialNumber=AAT 02404 r 10344595, rn=Rich d Hernandez, email=richard@ieg up.net 5Q841 g°r Date- 2025-12.11 0 237 Adobe Acrobat ver n- 2,34262 ❑ Rt� SCALE i 1"= 10' 5P-2 -438406 S I-2