Loading...
HomeMy WebLinkAboutW-438409N 7 MATCH LINE A -A' J ENTRY ENTRY ENTRY ENTRY u_ 45 DEGREE BEND (MJ) VV 2` 1 CONCRETE BLOCKING 41 Q - w O a �, TA; 02+62 (PER COR STD 330.1 b . ± 32 LF NEW 12" D.I. WATER MAIN - BURY 54" BELOW GRADE (TYPICAL) INSTALL 12" CAP (MJ) ON END OF WATERMAIN TO BE ABANDONED r5 CONNECTION POINT TO EXISTING 12" WATER MAIN TO REMAIN STA:02+94 --------------- FINAL CONNECTION TO EXISTING WATERMAIN PER COR STD 330.4 (BY CITY -FORCES): REMOVE EXISTING 12" 45 DEGREE BEND AND BLOCKING f INSTALL 12" SLEEVE (MJxMJ) WITH MEGALUG RESTRAINT WEDGES / INSTALL 12" DI PIPE SPOOL+00 I b I �1b if �- 25,80 � hh 16" Cw + tk +25.96 / EXISTING FIRE �J HYDRANT TO REMAIN { � I EXISTING 12" GV IN MH TO REMAIN } 2 .67 ry�O� + .490 49 o 25.4 an n a a 2n n en 16„ P1 U 8" PINE � —1-7 a 10'PINE ° $' PIN r 6''_pl E ' PINE �D E tx s x x x x xx x+2� .. _ WATER MANHOLE N 88022' 12" W 378.62' (378.39' DEED) (N LINE OF S 408' OF N 112 OF NW 114 OF SEC. 35-23-4) 66 T R =S 'T O 1061395 MATCH LINE A -A' 0 T X+— 25.51 25.48 SYMBOLS LEGEND PROPERTY LINE c o o� EXISTING, CONCRETE TO REMAIN E EXISTING TO REMAIN c EXISTING CURBING TO REMAIN EXISTING PARKING STRIPE TO REMAIN c`t'tii EXISTING ASPHALT TO BE SAWCIJT AND REMOVED EXISTING TO BE REMOVED r PROPOSED ASPHALT PAVEMENT TO MATCH EXISTING 1 PROPOSED CONCRETE TANK PAD PROPOSED CY) ml- w PROPOSED 12" D.I. WATER MAIN PROPOSED EASEMENT J w =00 00 EXISTING WATER MAIN (ABANDONED IN PLACE) er w CO ABBREVIATIONS: AST ABOVEGROUND STORAGE TANK DEF DIESEL EYHAUST FLUID ❑W DOUBLE WALL FE FIRE EXTINGUISHER N MAX MAXIMUM MIN MINIMUM O.C. ON CENTER TYP TYPICAL UST UNDERGROUND STORAGE TANK VIP VERIFY IN FIELD UTILITY NOTES: 1. CONTRACTOR TO VERIFY THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES WITHIN THE LIMITS OF CONSTRUCTION AND ADVISE THE ENGINEER OF RECORD OF ANY CONFLICTS IMMEDIATELY. 2. CONTRACTOR SHALL NOTIFY AND COORDINATE WATER SERVICE WITH LOCAL MUNICIPALITIES UTILITIES DEPARTMENT. 3. CONTRACTOR SHALL NOTIFY AND COORDINATE SEWER SERVICE WITH LOCAL MUNICIPALITIES UTILITIES DEPARTMENT- 4. CONTRACTOR TO COORDINATE INSTALLATION OF ELECTRICAL POWER SERVICE WITH LOCAL ELECTRIC COMPANY. 5- CONTRACTOR TO INSTALL PVC CONDUIT FOR TELEPHONE $ERVICE (TO PROPERTY LINE) AND GOORUINATE INSTALLATION OF SERVICE WITH TELEPHONE OPERATIONS. B. SEE SURVEY FOR LOCATION OF OTHER EXISTING UTILITIES. 7. SEE CIVIL SPECIFICATIONS AND REFERENCE DRAWING SHEETS FOR ADDITIONAL UTILITY NOTES. 8. ALL CROSSINGS OF WATER AND SEWER LINES MUST MAINTAIN PROPER CLEARANCE (SEE CIVIL SPECIFICATIONS AND REFERENCE DRAWING SHEETS). 9. CONTRACTOR IS RESPONSIBLE FOR COMPLYING TO THE SPECIFICATIONS OF THE CITYJTOWNS STANDARD CONSTRUCTION AND UTILITY REQUIREMENTS, 10. TREES SHALL NOT BE PLANTED WITHIN 10 FEET FROM THE WATER MAIN- 11. ALL CLEANOUT TOP ELEVATION SHALL MATCH FINISH GRADE ELEVATIONS. 12. ALL MECHANICAL JOINT (MJ) FITTINGS SHALL HAVE MEGALUG RANWGAD CONCRETE BLOCKS, IE(NE)=22.66' (FIND NOT I EWATER UTILITYIS DEVELMENT ENGINEERING DLJL GAFOUR 0111312D26 0HBr:y 01113i2026 LU J � W 0 r ❑ 0 a_ LU U) J_ D N O 00 Nt C) LO N 6 , U ililiiNITY ENGINEERIItiG CROUP, LLC 1208 Fast KcilIludy BUl1lu yard Suitc 230 Tampa, Florida 33602 [p 1: 813.131.4770 [f]; 813.445.1211 ww•w.icproup.nct Cert. of Auth. No. 603-536-31_1- O z LO CL 0 CD ' Cj C o < C3 m � CD 1` Y C13 (D a RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 Digitally signed by Richard Hemande DN: C=us, 2024 0410I344595,rcn R hard h Hernandez, email=richard@ieg up.n 50841 q� et q �a18'ry ti Date; 2425.12.1 1 0 13:15 SFO� ni.F a-06,00' AdobeAtrobatve on: ❑Gti)17.012.3D262 UTILITY SITE PLAN , L SCALE : 1" = 10' r SP-3,1 -438409 —. 1