Loading...
HomeMy WebLinkAboutW-438410INLkU 611 -, 1 4 " PINE - _ _ _ I�VC l q' PINEPINE _ - SYMBOLSLEGEND a" �'I 1 2" IN E _ z�-� SPINDYI 1 PINE Q _ fo P1 x �o J �J PI E 6' PI +� n r � �3 PROPERTY LINE Iz c Pi E Iz �M -- -- --- - = �r— -- — — --- — �' --- — — — -- --- --- ----- -- — ----- -- ---- -- — — —— —� - ------------- — o EXISTING CONCRETE TO REMAIN = — 4) W _ L /�� TR 8 PINE q E . V ? _— — — — — — �g { EXISTING TO REMAIN i ILn + ( c o b cp .a — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — N N 7r � CV .s — — — — — a+25.0�-y P EXISTING PARKING STRIPE TO REMAIN 26 47 Lx � +2655 u� $'o�to AD �$ EXISTING CONCRETE TO BE SAWCUTAN❑ REMOVED n, �j IE(W)=25.96' 1 b 4"PVC EXIS�JT�AREMOVED IVA 12"CMP�NDERWAI PROPOSED ASPHALT PAVEMENT TO MATCH EXISTING t rr 2%� PROPOSED CONCRETE TANK PAD v— — c IE(F)=25.94' 4fPROPOSED 4"P V C A EXISTING GRADE A L.i4 I I i4 J + - t` MEG 26.50 J~c „ _� � 26.55 MEG e .° _ �� PROPOSED EDGE OF PAVEMENT ELEVATION (FT) C) 0 U) tr 260 PROPOSED TOP OF CONCRETE f EDGE OF PAVEMENT Co zs.T 3 +28.s� 0 0 ELEVATION (FT) J w 200 ❑ter + MEG 26.50 MEG PROPOSED SURFACE FLOW J LU CO +_��� t2s,5; i if PROPOSED UNEVEN TRANSITION } ^,^ {'a W �• � b a i� i4 PROPOSED EVEN TRANSITION W — q g k " ABBREVIATIONS: ❑ H� el,� in ?a �.96�_99 p0 �4 r ti +' - +26.89 .� + ,� `�',�' " " AST ABOVEGROUND STORAGE TANK DEF DIESEL EXHAUST FLUID W r ❑W DOUBLE WALL FE FIRE EXTINGUISHER N '00q FIFE FINISHED FLOOR ELEVATION HP HIGH POINT MAX MAXIMUM MEG MATCH EXISTING GRADE MIN MINIMUM O.C. ON CENTER TOC TOP OF CURB TOS TOP OF SLAB TYP TYPICAL UST UNDERGROUND STORAGE TANK VIF VERIFY IN FIELD ENTf,Y ~ \ EN 2Y ~ ~ BEN N , ~ ra K w BUILDING LL ENTRY ENTRY ENTRY 14 A o� EN- Y F L :%FA J 5� .fi£ 4�=321 BUILDING HT=23.7' VENT N ENZRY U_ LL 4. .q '. I +`)'6 ' ° 7 �9 I� e O cy 196b 4- 7 v: 4' a d d W le. I a � C q � A. e d A. I � 27-63 03 a. 7:. 4 d ° p19¢ a2k q v. d. d r �0 . tO) ..4 q a. Y a zv T e f 4 a . if 4 a 4 q J d a a s a . 44 a d i \ + �Ifo a 9 �pR MEG ti MEG[ MEG MEG 266,$ CONSTRUCTION NOTE: CONTRACTOR TO VERIFY ALL UNDERGROUND UTILITIES BEFORE CONSTRUCTION BEGINS. NOTIFY THE FOR IN CASE OF ANY DISCREPANCY. CONTRACTOR TO ENSURE THE EXISTING DRAINAGE PATTERN FOR THE SITE SHALL BE MAINTAINED AT ALL TIMES THIS SHEET NOT REVIEWED BY CITY OF REfVTON z �C'L V C) 00 Nt C) C) LO N 6 , u i FINITY ENGINEERIItiG CROUP, LLC 1208 East Kcnncdy Butilcr-ard Suitc 230 Tampa, Florida 33602 [p ]: 813.131.4770 [f : 813.445.4211 W %'w.icprouP.nct Cw. of Auth. No. 603-536-314 O z LO CL 0 o r r CVj O >1 13 CD I` Y d3 a RICHARD HERNANDEZ, P.E. WA REG. NO. 50841 Digitally signed b Richard Hernande HEN DN: c=U5, Ok WA '4 serialNumber=AA 202 Sw �� 40410344595, cn=Richard Herna e7, email=rchard@ie up 50841 net is a` Date: 2025.12.1 1 Ow Ai. AdubeAcrobave ion, � 1k GRADING PLAN , ASCALE : 1" = 10' 1 ISP-4-4 / P—`t -438410