P_VMAC_Reno+Expand_ArchitecturalFloor Plans_251125_v1
UP UP UP FLOOR PLAN LEGEND EXISTING CONSTRUCTION TO REMAIN NEW CONSTRUCTION EXISTING ROOM OR ZONE TO REMAIN, NOT INCLUDED IN THIS SCOPE OF WORK NEW RECESSED FIRE EXTINGUISHER CABINET -STEEL. PROVIDE ABC MULTI-PURPOSE DRY CHEMICAL PORTABLE FIRE EXTINGUISHER, 10LB, UON NEW CASEWORK/ MILLWORK, COORDINATE ALSO WITH POWER AND DATA PLAN NEW DOUBLE GLAZED OPENING WITH ALUM OR HM FRAME AS INDICATED NEW DOOR AND FRAME OPENING FEC 2 HR FIRE RATED CONSTRUCTION (Fire Rating = 2) 1 HR FIRE RATED CONSTRUCTION (Fire Rating = 1) 1 HR RATED GLAZED FIRE BARRIER (Fire Rating = 1-GL) 2 HR RATED GLAZED FIRE BARRIER (Fire Rating = 2-GL) 1 HR RATED GLAZED FIRE & SMOKE BARRIER (Fire Rating = 1S-GL) S S S S S NEW CONSTRUCTION ROOM OR ZONE EXISTING ROOM OR ZONE TO BE RENOVATED 1. SEE SHEET G001 FOR GRAPHIC LEGEND INFORMATION. 2. SEE SHEET G002 FOR ADDITIONAL PLAN SPECIFIC GENERAL NOTES. 3. SEE SHEET A111 - A135 FOR SECTOR PLANS. 4. SEE SHEET A901 FOR PARTITION TYPES. 5. SEE SHEET A911 FOR DOOR SCHEDULE. 6. SEE SHEET A950 FOR FINISH SCHEDULE. 7. INTERIOR STEEL COLUMNS TO BE ENCLOSED BY PAINTED GYP FURRING WALL UNO. GENERAL PLAN NOTES A B C D E F G H J K L M N B.4 C.7 J.9 L.1 1 1 2 3 43.6 4.1 5 6 7 8 9 10 11 12 1 A322 1 A322 1 A321 1 A321 2 A322 2 A322 3 A322 3 A322 2 A321 2 A321 E.4 E.5 E.6 E.7 E.8 E.9 E.10 E.11 E.12 E.13 E.14 E.15 P L.6 E.3E.2E.1 O M.9 E.16 E.17 E.18 E.19 0.8 ELEC DATABEV. STOR FILL ROOM WEIGHT ROOM FUEL BARRECOVERY PLAYER LOCKER ROOM PLAYER ENG. EQ. STORAGE EQUIPMENT MAIN LAUNDRY GAMEDAY HELMETS TRUNKS OFFICE DRY STEAM SAUNA JAN HYDROTHERAPY STORAGE TREATMENT OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE EXAM EXAM MEP RR TEAM AUDITORIUM WALKTHROUGH ROOM MAIN LOBBY 2 A-302 1 A-301 IPF STORAGE ELEC RR RR STORAGE CONFERENCEOFFENSIVE LINE DEFENSIVE LINE TE ILB OLB QB RB DEF TEAM / DB (60)OFF TEAM (60) STORAGE JANITOR COMCAST EXIST. STAIRS TELE VESTIBULE ELEV RR RR FLEX ELEV. MACHINE ELEV DIRECTOR OFFICE SEWING OFFICE SECURITY RR ELEV. MACHINEELEV LOADING SECURITY SECURITY CORRIDOR WATER SERVICE ELEC HOLDING TRYOUT LOCKER ELEC TEL / DATA OFFICE STORAGE CORRIDOR RR ELEV ELEV MACHINE RR RR WET AREA OFFICE OFFICEDXA 1 A-302 2 A-301 BARBER A1 1 1 A1 1 2 A112 A113 A113 A114 A1 1 5 A1 1 4 A1 1 1 A1 1 2 A112 A113 A113 A114 A1 1 5 A1 1 4 1 A-321 1 A-321 2 A-321 2 A-321 1 A-322 1 A-322 2 A-322 2 A-322 3 A-322 3 A-322 C AB D E IPF NOT FOR CONSTRUCTION N Sheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MKA ENGINEERS 1301 Fifth Avenue, Suite 3200 Seattle, WA, 98101 Structural and Civil Engineers Prepared For Project No: 1200 5th Ave Suite 500 Seattle, WA 98101 BERGER PARTNERSHIP 1301 5th Ave Seattle, WA, 98101 Landscape Architects HENDERSON ENGINEERS 8345 Lenexa Drive, Suite 300 Lenexa, KS, 66214 Mechanical, Electrical, and Plumbing Engineers WJHW 3424 Midcourt Rd. #124 Carrollton, TX 75006 Audio/Visual 20 2 5 - 1 1 - 2 1 1 0 : 3 4 : 3 6 A M Au t o d e s k D o c s : / / 2 5 . 0 5 0 0 9 . 0 0 - V M A C / V M A C - M P - H O K - A R C H .r v t OVERALL FLOOR PLAN - LEVEL 1 A-101 VIRGINIA MASON ATHLETIC CENTER - EXPANSION & RENOVATION FOOTBALL NORTHWEST LLC 25.05009.01 2025 12 SEAHAWKS WAY, RENTON, WA 98056 Hellmuth, Obata & Kassabaum, Inc. 1 SHORELINE SUB DEV PERMIT 2025-11-24 3/64" = 1'-0"1 FLOOR PLAN - LEVEL 1 - SHORELINE UP UP UP UPUP FLOOR PLAN LEGEND EXISTING CONSTRUCTION TO REMAIN NEW CONSTRUCTION EXISTING ROOM OR ZONE TO REMAIN, NOT INCLUDED IN THIS SCOPE OF WORK NEW RECESSED FIRE EXTINGUISHER CABINET -STEEL. PROVIDE ABC MULTI-PURPOSE DRY CHEMICAL PORTABLE FIRE EXTINGUISHER, 10LB, UON NEW CASEWORK/ MILLWORK, COORDINATE ALSO WITH POWER AND DATA PLAN NEW DOUBLE GLAZED OPENING WITH ALUM OR HM FRAME AS INDICATED NEW DOOR AND FRAME OPENING FEC 2 HR FIRE RATED CONSTRUCTION (Fire Rating = 2) 1 HR FIRE RATED CONSTRUCTION (Fire Rating = 1) 1 HR RATED GLAZED FIRE BARRIER (Fire Rating = 1-GL) 2 HR RATED GLAZED FIRE BARRIER (Fire Rating = 2-GL) 1 HR RATED GLAZED FIRE & SMOKE BARRIER (Fire Rating = 1S-GL) S S S S S NEW CONSTRUCTION ROOM OR ZONE EXISTING ROOM OR ZONE TO BE RENOVATED 1. SEE SHEET G001 FOR GRAPHIC LEGEND INFORMATION. 2. SEE SHEET G002 FOR ADDITIONAL PLAN SPECIFIC GENERAL NOTES. 3. SEE SHEET A111 - A135 FOR SECTOR PLANS. 4. SEE SHEET A901 FOR PARTITION TYPES. 5. SEE SHEET A911 FOR DOOR SCHEDULE. 6. SEE SHEET A950 FOR FINISH SCHEDULE. 7. INTERIOR STEEL COLUMNS TO BE ENCLOSED BY PAINTED GYP FURRING WALL UNO. GENERAL PLAN NOTES A B C D E F G H J K L M N B.4 C.7 J.9 L.1 1 1 2 3 43.6 4.1 5 6 7 8 9 10 11 12 1 A322 1 A322 1 A321 1 A321 2 A322 2 A322 3 A322 3 A322 2 A321 2 A321 E.4 E.5 E.6 E.7 E.8 E.9 E.10 E.11 E.12 E.13 E.14 E.15 P L.6 E.3E.2E.1 O M.9 E.16 E.17 E.18 E.19 0.8 DINING KITCHEN WOMENS FB STAFF LOCKER TEL / DATAELEC RRRR GM TEL / DATA ELEC. PERS. PANTRY DRAFT ROOM MENS FB COACHES LOCKER MENS FB STAFF LOCKERS OFFICE VIDEO WORKROOM VIDEO WORKROOM VIDEO STORAGE SERVER ROOM VIDEO STORAGE TEL / DATA ELEC FB STAFF GROWTH PRODUCTION #2 RR RR UNIVERSAL CARDIO MEZZANINE OPEN TO WEIGHT ROOM BELOW OPEN TO BELOW OPEN TO BELOW CONFERENCE STORAGE OFFENSE (20)DEFENSE / ALL STAFF (53) HEAD COACH PROD #3 EQUIPMENT CONTROL STAGE STORAGE PRODUCTION #1 PODCAST AV / DATA NFL CART STORAGE RADIO #2 RADIO #1 PANTRY TELE ELEC PRESS WORKROOMPRESS CONFERENCE INDOOR PRACTICE FIELD AT LEVEL 1 BELOW RR RR ELEV TEAM ROOM MEP FLEX ELEV PERS.PERS. PERS. PERS. PERS. PERS. PERS. PERS. PERS. RR PERS. PERS. COORD BREAK COACHPERS.PERS.PERS. PERS. PERS. PERS. COORD COORD COORD RR FB OFFICES COACH COACH COACH ADMIN COACH COACH COACH COACH COACH COACH COACH COACH DRY JAN REF FREEZER ELEV RR CHEF ELEV PREP PHONE COACH COACH COACH COPY COACHCOACH COACH COACH COPY RR STORAGE RR 7' - 4 1 / 2 " 6' - 0 " 2 A-302 1 A-301 1 A-302 2 A-301 SHOWERS & TOILETS A1 2 1 A1 2 2 A122 A123 A123 A124 A1 2 5 A1 2 4 A1 2 5 A1 2 4 A123 A124 A122 A123 A1 2 1 A1 2 2 1 A-321 1 A-321 2 A-321 2 A-321 1 A-322 1 A-322 2 A-322 2 A-322 3 A-322 3 A-322 C AB D E IPF NOT FOR CONSTRUCTION N Sheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MKA ENGINEERS 1301 Fifth Avenue, Suite 3200 Seattle, WA, 98101 Structural and Civil Engineers Prepared For Project No: 1200 5th Ave Suite 500 Seattle, WA 98101 BERGER PARTNERSHIP 1301 5th Ave Seattle, WA, 98101 Landscape Architects HENDERSON ENGINEERS 8345 Lenexa Drive, Suite 300 Lenexa, KS, 66214 Mechanical, Electrical, and Plumbing Engineers WJHW 3424 Midcourt Rd. #124 Carrollton, TX 75006 Audio/Visual 20 2 5 - 1 1 - 2 1 1 0 : 3 4 : 3 8 A M Au t o d e s k D o c s : / / 2 5 . 0 5 0 0 9 . 0 0 - V M A C / V M A C - M P - H O K - A R C H .r v t OVERALL FLOOR PLAN - LEVEL 2 A-102 VIRGINIA MASON ATHLETIC CENTER - EXPANSION & RENOVATION FOOTBALL NORTHWEST LLC 25.05009.01 2025 12 SEAHAWKS WAY, RENTON, WA 98056 Hellmuth, Obata & Kassabaum, Inc. 1 SHORELINE SUB DEV PERMIT 2025-11-24 3/64" = 1'-0"1 FLOOR PLAN - LEVEL 2 - SHORELINE UP UP UP FLOOR PLAN LEGEND EXISTING CONSTRUCTION TO REMAIN NEW CONSTRUCTION EXISTING ROOM OR ZONE TO REMAIN, NOT INCLUDED IN THIS SCOPE OF WORK NEW RECESSED FIRE EXTINGUISHER CABINET -STEEL. PROVIDE ABC MULTI-PURPOSE DRY CHEMICAL PORTABLE FIRE EXTINGUISHER, 10LB, UON NEW CASEWORK/ MILLWORK, COORDINATE ALSO WITH POWER AND DATA PLAN NEW DOUBLE GLAZED OPENING WITH ALUM OR HM FRAME AS INDICATED NEW DOOR AND FRAME OPENING FEC 2 HR FIRE RATED CONSTRUCTION (Fire Rating = 2) 1 HR FIRE RATED CONSTRUCTION (Fire Rating = 1) 1 HR RATED GLAZED FIRE BARRIER (Fire Rating = 1-GL) 2 HR RATED GLAZED FIRE BARRIER (Fire Rating = 2-GL) 1 HR RATED GLAZED FIRE & SMOKE BARRIER (Fire Rating = 1S-GL) S S S S S NEW CONSTRUCTION ROOM OR ZONE EXISTING ROOM OR ZONE TO BE RENOVATED 1. SEE SHEET G001 FOR GRAPHIC LEGEND INFORMATION. 2. SEE SHEET G002 FOR ADDITIONAL PLAN SPECIFIC GENERAL NOTES. 3. SEE SHEET A111 - A135 FOR SECTOR PLANS. 4. SEE SHEET A901 FOR PARTITION TYPES. 5. SEE SHEET A911 FOR DOOR SCHEDULE. 6. SEE SHEET A950 FOR FINISH SCHEDULE. 7. INTERIOR STEEL COLUMNS TO BE ENCLOSED BY PAINTED GYP FURRING WALL UNO. GENERAL PLAN NOTES A B C D E F G H J K L M N B.4 C.7 J.9 L.1 1 1 2 3 43.6 4.1 5 6 7 8 9 10 11 12 1 A322 1 A322 1 A321 1 A321 2 A322 2 A322 3 A322 3 A322 2 A321 2 A321 E.4 E.5 E.6 E.7 E.8 E.9 E.10 E.11 E.12 E.13 E.14 E.15 P L.6 E.3E.2E.1 O M.9 E.16 E.17 E.18 E.19 0.8 FITNESS HOSPITALITY ELEC RESTROOM RESTROOM CATERING STORAGE ELEC MEETING ROOM RESTROOMS RESTROOMS MEETING ROOM STORAGE COPY BREAK OUT MEETING ROOM BREAK OUT OFFICE IT ELEC STORAGE RESTROOM RESTROOM IT STORAGE HOSPITALITY IT BULLPEN HOSPITALITY PRESIDENT'S OFFICE HOSPITALITY ROOF TERRACE TERRACE OPEN TO BELOW MEETING ROOM OPEN TO BELOW INDOOR PRACTICE FIELD AT LEVEL 1 BELOW MENS STAFF LOCKER ? ? UP5% ELEV TYP. OFFICETYP. OFFICE MEETING ROOM MEETING ROOM STAIRS STORAGE OFFICE OFFICE IT BUILD ELEV OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OPEN OFFICE COPY FOCUSOFFICEOFFICEOFFICE OPEN COLLABORATION OFFICEOFFICE FOCUS FOCUS OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE FOCUS FOCUS OFFICEOFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICEOFFICE OFFICE RR BUS. OFFICE BUS. OFFICE BUS. OFFICE MEETING ROOM JAN RR FURNITURE STORAGEELEV STORAGE TEL / DATA ELEV STORAGE OPEN OFFICE IT OPEN TO BELOW OPEN TO BELOW MEETING ROOM OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE EDITING BAY ELEC TEL / DATA COPYCOPY MARKETING / GRAPHIC DESIGN WORK ROOM STORAGE ST O R A G E S T O R A G E 4' - 0 " JANITOR 2 A-302 1 A-301 1 A-302 2 A-301 A1 3 1 A1 3 2 A132 A133 A133 A134 A1 3 5 A1 3 4 A1 3 1 A1 3 2 A132 A133 A133 A134 A1 3 5 A1 3 4 1 A-321 1 A-321 2 A-321 2 A-321 1 A-322 1 A-322 2 A-322 2 A-322 3 A-322 3 A-322 C AB D E IPF NOT FOR CONSTRUCTION N Sheet Number Original is 42 x 30. Do not scale contents of this drawing. Sheet Title Professional Seals Key Plan In Association with Project All reproduction & intellectual property rights reserved © No. Description Date MKA ENGINEERS 1301 Fifth Avenue, Suite 3200 Seattle, WA, 98101 Structural and Civil Engineers Prepared For Project No: 1200 5th Ave Suite 500 Seattle, WA 98101 BERGER PARTNERSHIP 1301 5th Ave Seattle, WA, 98101 Landscape Architects HENDERSON ENGINEERS 8345 Lenexa Drive, Suite 300 Lenexa, KS, 66214 Mechanical, Electrical, and Plumbing Engineers WJHW 3424 Midcourt Rd. #124 Carrollton, TX 75006 Audio/Visual 20 2 5 - 1 1 - 2 1 1 0 : 3 4 : 4 0 A M Au t o d e s k D o c s : / / 2 5 . 0 5 0 0 9 . 0 0 - V M A C / V M A C - M P - H O K - A R C H .r v t OVERALL FLOOR PLAN - LEVEL 3 A-103 VIRGINIA MASON ATHLETIC CENTER - EXPANSION & RENOVATION FOOTBALL NORTHWEST LLC 25.05009.01 2025 12 SEAHAWKS WAY, RENTON, WA 98056 Hellmuth, Obata & Kassabaum, Inc. 1 SHORELINE SUB DEV PERMIT 2025-11-24 3/64" = 1'-0"1 FLOOR PLAN - LEVEL 3 - SHORELINE