Loading...
HomeMy WebLinkAboutR-436319NW 1/4 OF NW 1/4 & THE NE 1/4 OF NW 1/4 SEC 9, TWN 23 N, RGE05E,W.M. 0 LU 0 LU 5 O z O Q rr LU I O 0 Q w J Q 0 0 U L 0 U U c 2, N 0 0 CD U N a E 0 _ 3 0 a 0 0 N 0 0 N CD N 0 0 0 0 N N 4I E :_ CD 0 N cr CD 0 PROPERTY LINE (TYP) 360 355 350 345 340 335 330 325 320 v Icc I< F LG 2H:1V ' MAX C SEE SHEET C6.11 FOR CONTINUATION CB #11, TYPE 1 STA. 69+92.05, 124.72' RT RIM=343.61 6" IE IN=342.78 (NE) Uj 6" IE OUT=342.75 (SE) PROPOSED GRADE AT CENTERLINE EXISTING PH1 GRADE AT CENTERLINE -1.50% -------------------------------------------- MATCH EXISTING CB #3, TYPE 2-48", GRADE (TYP) STA. 44+51.34 RIM=344.11 12" IE IN=338.96 (NE) 6" IE IN=339.46 (SW) 12" IE OUT=338.96 (SE) I 0 0 0 0 0 M W Q W J J a 0 0 0 0 + 0 co Q F- Cn 0- c� co m W J J Q PLANTER CELL WEIR WALL / II STA. 30+20.39, 15.65' LT 6" IE OUT=342.61 CB #2, TYPE 1 STA. 30+57.00, 15.00' LT RIM=341.98 12" IE IN=335.67 (NW) co 12" IE OUT=335.67 (SW) J W F6"DI@0.47% 71 LF12'fSp@462% T -1.63% I` 00 CO + O co F- a_ 2 LU Z .32 as QLJ Iz O o NLJ U- W 12LF12"SD@1.00% ROW LINE(TYP) YT( P) II rn co Y M M m J Q NN W C/1 � W 0 z p rn c' U - Cn W ++ W 2i O Q CO z O co 0 Q w U- LL w J J Q 12 LF 12" SD @ 1.00% CB #1, TYPE 2-48", n4 SOLID LOCKING LID, EX 29 LF CONNECT TO EXISTING STUB 12" SD STA. 30+59.92, 11.37' RT @ 1.00% RIM=342.50 12" IE IN=334.34 (NE) EX. 12" IE OUT=334.34 (SE) PH 1 EX CB (S), TYPE 2-48" RIM=341.23 12" IE IN=334.05 (NW) O d) N co T� Cp M <t p M M M N O O M -4 nl CV Chi nl nl CV CV CV <t �1 <t �1 <F ",I-� <I- <F <F <F <F M co M co c"M co M m c"M m M c"M m c"M m M M M 29+20 29+60 30+00 30+40 30+80 Call 811 two business days before you di 0L gg 31+20 2 CIVIL CONSTRUCTION PERMIT - 3RD SUBMITTAL 1 CIVIL CONSTRUCTION PERMIT - 2ND SUBMITTAL 0 CIVIL CONSTRUCTION PERMIT NO. REVISION ALL STORM IS PRIVATE UNLESS OTHERWISE INDICATED ON THESE PLANS 360 355 350 345 340 335 330 325 320 SURVEYED: ZLN DESIGNED: MDR JSF 12/8/2025 JSF JSF 08/31/2025 JSF °RPWN' RAG MDR 05/27/20241 JSF CHECKED: MNF BY DATE APPR aPP�vEo: JSF II III ;I�■ ■ ■� �■ 1 ��ii � I� II rim: III I- �O KEY PLA ti NTS LEGEND: 1. ALL CATCH BASINS WITHIN ROADWAY SECTION SHALL BE ON CENTERLINE AND CONSTRUCTED WITH SOLID LOCKING LIDS, PROPERTY LINE /ROW LINE UNLESS NOTED OTHERWISE. - - O2 CHANNEL DRAIN SHALL BE 6" WIDTH ADS DURASLOPE (0.7% - ROW CENTERLINE SLOPE) WITH 8" MIN DEPTH AT HIGH END, AND WITH CAST IRON GRATE. UNIT LOT LINE O3 CONTRACTOR SHALL PROTECT BIORETENTION AREA DURING UNIT LOT NUMBER CONSTRUCTION TO PREVENT COMPACTION OR SILTATION. NO CONSTRUCTION STORMWATER SHALL BE PERMITTED TO ENTER BIORETENTION PLANTERS. CONTRACTOR SHALL BE PROPOSED ASPHALT RESPONSIBLE TO RECONSTRUCT BIORETENTION PLANTER SHOULD FOULING OR COMPACTION OCCUR. O4 CONNECT TO EXISTING STORM STUB. CONTRACTOR SHALL PROPOSED GRAVEL CONFIRM LOCATION AND ELEVATION OF STRUCTURE AND CONNECTED PIPES AND NOTIFY ENGINEER OF ANY o DISCREPANCIES PRIOR TO CONSTRUCTION. e p p PROPOSED CONCRETE 6 . 5. PLACE ETHAFOAM PAD BETWEEN PIPE CROSSINGS WITH LESS THAN 12" CLEARANCE. CURB 6. ALL STORM DRAINAGE PIPE 12" OR LARGER SHALL BE PVC C900 PER WSDOT STANDARD SPECIFICATIONS C9.30.1(5)A 360 PROPOSED CONTOUR UNLESS INDICATED OTHERWISE. ®❑ a O m CATCH BASIN 7. ALL STORM DRAINAGE PIPE 8" OR SMALLER SHALL BE PVC SDR35 PER WSDOT STANDARD SPECIFICATIONS 9-05.1(5) • CLEANOUT UNLESS INDICATED OTHERWISE.:........................................................................... :.................................................... : BIORETENTION PLANTER ::............: : 8. ALL BIORETENTION OVERFLOW CB'S SHALL HAVE A MIN. 6" ........................................................................... : RAISED DI BEEHIVE/DOMED GRATE. BIORETENTION OUTFACE 9. AREA DRAINS SHALL BE NYOPLAST 12" DRAIN BASIN W/ DOMED CAST IRON GRATE, AND MIN. 1' SUMP. �# BIORETENTION ID 10. ROOF DRAINS SHALL BE 2% MIN. SLOPE. ALL ROOF SIDEWALK INLET rl 3 DOWNSPOUT CONNECTIONS SHALL INCLUDE A 6" CLEANOUT �33 WITH A CAP FLUSH TO FINISHED GRADE. BIORETENTION BOTTOM UPHILL DOWNHILL OVERFLOW OVERFLOW 8" CONNECTED NUMBER # AREA (SF) BOTTOM BOTTOM CB ELEV. OUTLET TO ELEV. ELEV. (CB RIM) IE C1 173 342.61 341.48 #4 341.98 336.98 CB #2 R-436319 S IN COMPLIANCE WITH CITY OF RENTON STANDARDS W@S�r 0 10 20 40 �� o oy DEVELOPMENT ENGINEERING �ID - � HBray 12/31 /2025 1 inch = 20 ft. HORZ - �' 39847 1601 5th Avenue, Suite 1600 0 2.5 5 10 'I'p�y �`'EGIST- Seattle, WA 98101 �SSIONAL E206.622.5822 1 inch = 5 ft. VERT www•kpff.com 12/09/2025SCALE: DATE. HORIZONTAL: NAD 1983/1991 CITY OF SOLERA TOWNHOMES 05/30/202, RENTONFIELD2842 NE SUNSET BLVD PAGE. OK: RENTON, WA 98056 LNG N0 ONE INCH • AT FULL SCALE DATUM Planning/Building/Public Works Dept. ROAD & STORM DRAINAGE PLAN AND PROFILE C 6. O IF NOT ONE INCH SCALE ACCORDINGLY ALLEY A sHEEr:19 oF:55 co ti M �O N U coco co O of n CO 0 N Q J