Loading...
HomeMy WebLinkAboutR-436332a, 3 0 0 i i n 0 0 0 0 U U c .o+ 0 i 0 0 Q N V) E 0 3 0 a Q> 0 co 00 N 0 0 i rn 0 CN N 0 0 0 0 N E :_ a CD 0 N CD 0 � \ 00, Ss /2 cP O \ : O 0 LU \ c090s�s� \ W �� 61 � 1 !i � \90 O z O LU gyp. Rom. GJ U) x s �= o�oz'� A o s " +� 0 GAO �O� — — PROPERTY LINE — — ROW LINE ROW CENTERLINE UNIT LOT NUMBER w w WATER MAIN TEE N GATE VALVE 1 CONCRETE THRUST BLOCK SS SS SEWER MAIN 0 SANITARY SEWER MANHOLE ► FLOW DIRECTION ARROW NW 1/4 OF NW 1/4 & THE NE 1/4 OF NW 1/4 SEC 9, TWN 23 N, RGE05E,W.M. v UUNNLU I I U tXIS I INU SLVVLK MAIN 5 I Ub 3. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER FITTINGS PER COR STD PLANS 330.1, 330.2 AND 330.3 4. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION 5. WATER MAIN PIPE DEFLECTION SHALL NOT EXCEED ONE HALF OF THE PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE 6. WATER MAIN SHALL BE RJ CLASS 52 DUCTILE IRON PIPE WITH POLYETHYLENE ENCASEMENT. "FIELD-LOK" GASKETS ARE NOT PERMITTED 7. ALL ROADWAYS IN VARYING WIDTH UTILITY AND ACCESS EASEMENT UNLESS OTHERWISE NOTED. 8. CONSTRUCT POLY PIGGING STATIONS AT CONNECTIONS TO EX. WATER MAINS PER STD PLAN 300.7. • Call 811 • • two business days before you dig �D� 11UU UK AF'F'KUVLU LIJUAL. FIELU LUUK UASKE 15 AKE NU I F'EKMI I I EU. 10. CONTRACTOR SHALL POTHOLE AND VERIFY LOCATION AND ELEVATION OF SEWER AND WATER MAIN EXTENSION POINTS OF CONNECTION, AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 11. WATER PRESSURE EXCEEDS 80PS1. INDIVIDUAL UNIT PRV'S ARE REQUIRED DOWNSTREAM OF ALL DOMESTIC WATER METERS (PER COR STD. PLAN 340.4) 12. DOUBLE CHECK VALVE ASSEMBLY (DCVA) REQUIRED DOWNSTREAM OF ALL INDIVIDUAL UNIT METERS PER COR STD 340.8. 13. ALL SIDE SEWERS SHALL BE 6" PVC SDR35 PER WSDOT STANDARD SPECIFICATIONS 9-05.1(5) WITH 2% MIN SLOPE UNLESS INDICATED OTHERWISE. 14. IN AREAS OF FILL, NEW ROADWAY SUBGRADE SHALL BE FILLED AND COMPACTED BEFORE EXCAVATION FOR INSTALLATION OF NEW WATER MAINS (TYP). 2 CIVIL CONSTRUCTION PERMIT - 3RD SUBMITTAL 1 CIVIL CONSTRUCTION PERMIT - 2ND SUBMITTAL 0 CIVIL CONSTRUCTION PERMIT NO. REVISION SURVEYED: ZLN DESIGNED: MDR JSF 12/8/2025 JSF JSF 08/31/2025 JSF DRAWN: RAG MDR 05/27/20241 JSF CHECKED: MNF BY DATE APPR JSF 0 15' 30' 60' 1 inch = 30 feet 12/09/2025 06' 0'py9O�� �° M� �I N HI r� ro WIZ � I � 1 o O + + o LnLU U W W 2 w Z_ Ito J W 2 1 W Cn 1 Q 1 � CONDITION OF APPROVAL: EASEMENTS SHALL BE REVISED TO CORRECT DEFICIENCIES OUTLINED BY CITY OF RENTON PER EXHIBIT PROVIDED BY THE DEVELOPMENT ENGINEERING PROJECT MANAGER SENT TO APPLICANT VIA EMAIL ON 12/31 /2025 REVISED EASEMENTS SHALL BE PROVIDED TO THE DEVELOPMENT ENGINEERING PROJECT MANAGER FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION CLOSEOUT SEM 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.knff.com I gm HORIZONTAL- NAD 19W/1991 CITY OF 11 RENTON ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY R-436332 w-436301 s-436301 IN COMPLIANCE WITH CITY OF RENTON STANDARDS WATER UTILITY DEVELOPMENT ENGINEERING JValdez 12/18/2025 Ul r HBray 12/31/2025 U1 WASTEWATER UTILITY 'D jstowell 01 /02/2026 L DATE. SOLERA TOWNHOMES 05/30/202, 2842 NE SUNSET BLVD FIELDBOOK: FADE RENTON, WA 98056 DRAWING NO: BLOCK C COMPOSITE UTILITY PLAN C7'00 SHUT:32 OF.55 co M C)o 0 00 LO ti O N Q J