Loading...
HomeMy WebLinkAboutW-436306co c9 co LU I- 3 I m w J Q I i 0 U L _ .) U U / _ 0 / 0 0 Q i N 1 E O 3 0 Q> 0 00 N O O i 0 N 1 0 0 0 0 N N ej 4 C E _�c CL Ln CD 0 N 0 0 of O LL_ D SSMH #8 U i SD SD n LU 50 00 w LU a LU StA 50+34.50, 9.96' RT CONNECT TO EXISTING 12" STUB PER COR STD PLN 300.4 (1) 12"x6" TEE (FL) r (1) 6" GV (FLxMJ) I > I t N (1) F.H. ASSEMBLY PER ( COR STD PLAN 310.1, 310.2 & 310.3 II (1) CONCRETE BLOCKING 370 SSMH #8, 60" 365 STA. 50+33.37, 0.04' LT RIM=352.96 8" IE IN=341.11 (N) 8" IE OUT=337.68 (SW) I 360 + o N O N O + o Q = u MATCH EX - 355 w BACK OF LUQ SIDEWALK DEPTH 350 ±6.63' - - FIRE HYDRANT ASSEMBLY - 12"x 6" TEE (MJxFL) XIjIIX _I 345 REMOVE EX CAF PER CGR STD PLAN 300.4 ONNECT DIRECTLY TO STUBBED EXISTING 12" W TER MAIN 340 SIT 50+34.5)0 EL=345.?0 PH 1 EX SSMH, 48"I 335 I cV I co M 50+00 SEE SHEET C7.15 FOR CONTINUATION NW 1 /4 OF NW 1 /4 & THE NE 1 /4 OF NW 1 /4 SEC 9, TWIN 23 N, RG E 05 E, W.M. STA 50+39.55 EL=345.20 22.50 VERTICAL & HORIZONTAL BEND (MJ) (1) CONCRETE BLOCKING SSMH #9, 48" STA. 50+49.52, 5.00' LT RIM=353.35 8" IE IN=341.55 (NE) 8" IE OUT=341.45 (S) 13 LF 12" DI WM (RJ) rr 55 LF 12" DI WM (RJ) 47 LF 8" PVC SS @ 2.00% 0 \-STA 50+51.29 17 LF 8" PVC EL=347.48 SS @ 2.00% 22.5° VERTICAL AND SSMH #10.48" STA. 50+96.48, 5.00' LT RIM=354.52 8" IE IN=342.59 (NE) 8" IE IN=342.59 (NW) 8" IE OUT=342.49 (SW) II N � O O O o C+ + O O LO W co U CD Lu LU J Q J Q ;D HORIZONTAL BEND (MJ) (1) CONCRETE BLOCKING 19 LF 12" DI WM (RJ) 81 __ 67 LF 12" DI WM (RJ) 12"x 12" TEE (FLxFL) STA 51+06.48 75 LF 8" PVC SS @ 2.00% EL=347.75 N ti N I` N co M M M COLo M M M 50+40 50+80 51+20 CONDITION OF APPROVAL: APPLICANT SHALL SPECIFY ON THE PLANS IF MH #8 IS AN INSIDE OR OUTSIDE DROP PLANS SHALL BE REVISED AND RESUBMITTED TO THE DEVELOPMENT ENGINEERING PROJECT MANAGER FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION SEWERMAINS STA 51 +73.06 EL=348.42 11.25" HORIZONTAL BEND (MJ) (1) CONCRETE BLOCKING CD I` N co cco 51+60 SSMH #11, 48" STA. 51 +71.49, 5.00' LT RIM=356.36 8" IE IN=344.19 (NE) 8" IE OUT=344.09 (SW) -----+------- l 54 LF 8" PVC SS @ 2.00% PROPOSED GRADE AT CENTERLINE EXISTING PH1 GRADE AT CENTERLINE 70 LF 8" PVC SS @ 2.00% SSMH #12, 48" STA. 52+24.70, 5.22' RT RIM=357.38 STA 51+91.37 8" IE IN=345.36 (N) EL-348.60 8" IE OUT=345.26 (SW) 11.25" HORIZONTAL BEND (MJ) (1) CONCRETE BLOCKING co O� C0 CD N O� O Lc3 O LO ti ti ti LO M U-) cM U-) U-) U-) co co co co co 52+00 52+40 CON>ErT`j0 EXISTINQ,42"`STUB / ER CO ' TD PLN 300.4 �EMOVE EX CAP (1) 12"x6" TEE (1�6" GATE VALVnECOR xMJ) (1) F.H. ASSEMBLY STD PLAN 3�, 310.1H ie��1'YrTr n� � i� �In ti co M co SSMH #13, 48" co LO STA. 52+95.21, 3.94' RT Q RIM=357.54 cn cn 8" IE IN=346.85 (NE) 0 = 8" IE OUT=346.75 (S) LU J III J 31 LF12"DI WM (RJ) Q a - - - FIRE HYDRANT ASSEMBI- 12"x 6" TEE (MJxFL) -------- 370 KEY PLAN NTS REFER TO SHEET C0.01 & C0.02 FOR CITY OF RENTON WATER AND SEWER NOTES REFER TO SHEET C7.00 FOR WATER AND SEWER CONSTRUCTION NOTES LEGEND: - - PROPERTY LINE CENTERLINE - - SANITARY SEWER SS 0 SANITARY SEWER MANHOLE FLOW DIRECTION ARROW C SEWER STUB WATER W N GATE VALVE CONCRETE THRUST BLOCK CONDITION OF APPROVAL: WATER METER LOCATIONS SHALL BE RELOCATED OUTSIDE OF DRIVE AISLE FOR ALL UNITS PLANS SHALL BE REVISED AND RESUBMITTED TO THE DEVELOPMENT ENGINEERING PROJECT MANAGER FOR REVIEW AND APPROVAL PRIOR TO WATER METER INSTALLATION 365 SSMH #15, 8" STA. 53+62 07, 5.00' RT RIM=356.7 8" IE OUT= 47.98 (W) 360 MATCH EX BACK OF WALK 355 rWi +I 23 LF 8" PVC \-38 LF 8" PVC SS @ 2.00% SS @ 1.50% D95 96 SSMH #14, 48" STA 52+95.84 EL-349.65 STA. 53+22.35, 3.07' RT 45° BEND (MJ) RIM=357.31 (1) CONCRETE 8" IE IN=347.41 (E) BLOCKING 8" IE OUT=347.31 (SW) STA 53+21.89 CONNECT DIRECTLY TO STUBBED EL=349.91 EXISTING 12" WATER MAIN 45" BEND (MJ) STA 53+68.80 (1) CONCRETE BLOCKING EL=350.37 LO � N OLO I` Lf") C_ LO LO LO LO U-)Lf� M COco co M co co 52+80 53+20 53+60 ID TOP UTILITY BOTTOM UTILITY CLEARANCE (FT) NAME SIZE (IN) IE NAME SIZE (IN) IE aWater a 12 348.8 Sewer 8 343.84 4.29 9Storm 9 Drain 12 351.26 Sewer 8 343.99 6.60 95 Water 12 349.51 Sewer 8 347.01 1.83 96 Storm Drain 12 351.92 1 Sewer 8 347.17 14.08 • Call 811 • • two business days before you dig 2 CIVIL CONSTRUCTION PERMIT - 3RD SUBMITTAL 1 CIVIL CONSTRUCTION PERMIT - 2ND SUBMITTAL 0 CIVIL CONSTRUCTION PERMIT NO. REVISION SURVEYED: ZLN DESIGNED: MDR JSF 12/8/2025 JSF JSF 08/31/2025 JSF DRAWN: RAG MDR 05/27/2024 JSF CHECKED: MNF BY DATE APPR APPROVED: JSF 350 345 340 335 1VASgI 0 10 20 40 1 inch = 20 ft. HORZ 39847 1601 5th Avenue, Suite 1600 0 2.5 5 10 'f'pfy �EGISTi4'! 4`t�4 Seattle, WA 98101 1 inch = 5 fl. VERT �SSIONAL l 206.622.5822 i HYDRANT MECHANICAL JOINT / CAP BLOW OFF ►tj PIV ® UTILITY CROSSING ID TOP UTILITY BOTTOM UTILITY CLEARANCE (FT) NAME SIZE (IN) IE NAME SIZE (IN) IE 68 Storm Drain 12 349.42 Sewer 8 337.95 10.80 69 Storm Drain 8 349.94 Sewer 8 338.05 11.22 70 Storm Drain 12 349.65 Side Sewer 6 339.03 10.12 71 Water 12 346.29 Side Sewer 6 339.13 6.66 72 Q Storm Drain 12 349.75 Side Sewer 6 339.37 6.80 73 Water 12 346.67 Side Sewer 6 339.47 9.99 74 Storm Drain 12 349.96 Side Sewer 6 340.03 9.43 75 Water 12 347.45 Side Sewer 6 340.13 6.82 76 Water 12 347.77 Sewer 8 339.95 7.15 77 Storm Drain 12 350.01 Water 12 347.72 2.29 78 Storm Drain 12 350.17 Side Sewer 6 340.86 8.81 79 Water 12 347.83 Side Sewer 6 340.96 6.37 80 Storm Drain 12 350.47 Side Sewer 6 341.85 8.12 81 Water 12 348.13 Side Sewer 6 341.95 5.68 82 Storm Drain 12 350.66 Side Sewer 6 342.47 7.69 83 Water 12 348.32 Side Sewer 6 342.57 5.25 84 Storm Drain 12 350.84 Side Sewer 6 343.14 7.20 85 Water 12 348.5 Side Sewer 6 343.24 4.76 86 Storm Drain 12 350.96 Water 12 348.62 2.34 87 Water 12 348.66 Side Sewer 12 343.73 3.93 88 Storm Drain 12 351 Side Sewer 6 343.63 6.87 89 Storm Drain 8 351.67 Sewer 8 343.51 7.49 90 Storm Drain 8 351.53 Water 12 348.70 __ ::I 1.83 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 12/09/2025 www.kpff.com OHDRZMA N D1983ag /1991 • CITY OF A& AR lRuff RENTON DATUM Planning/Building/Public Works Dept. �r w-436306 s-436306 IN COMPLIANCE WITH CITY OF RENTON STANDARDS (D WATER UTILITY DEVELOPMENT ENGINEERING 01 FJValdez 12/18/2025 HBray 12/31/2025 WASTEWATER UTILITY jstowell 01 /02/2026 DATE: SOLERA TOWNHOMES 05/30/202, 2842 NE SUNSET BLVD . OK: PAGE RENTON, WA 98056 PAGE DRAWING N0: WATER AND SEWER PLAN & PROFILE ALLEY C C7.13 sHEEr:37 oF:55 co M 0 O Of 0 CO N J