Loading...
HomeMy WebLinkAboutW-436311NW 1/4 OF NW 1/4 & THE NE 1/4 OF NW 1/4 SEC 9, TWN 23 N, RGE05E,W.M. co QO co 0 LU I— U) LU 5 0 2 Z 0 I- � Q�■ LL LU I �0 V ) 01 3 vi J a 0 N I a`> d 0 U L c 0 U U c N W 0 0 N N a 1= 0 3 0 a Q> DO cn rO N 0 0 N rn rn 0) oD 0 N O O O O N IV W .i W x ti E E a CD N 0 0 DocuSign Envelope ID 345B681 D-914F-4F2D-AB59-7C 192D3B78A3 5' 1 NOT TO SCALE MANHOLE FRAME AND COVER SEE STD PLAN 401 ADJUSTMENT RINGS AND MORTAR JOINTS SEE NOTE 3 FIRST STEP SHALL BE A MAXIMUM OF 18" BELOW THE COVER CONE (ECCENTRIC) STEPS - POLYPROPYLENE STEPS SHALL BE INCLUDED RUBBER GASKETED JOINTS SEE NOTE 5 IF REQUIRED, LADDER -POLYPROPYLENE SHALL BE ATTACHED TO MANHOLE MAX PIPE SIZE - 'E' SHELF AND CHANNEL SHALL BE 3000 PSI CONCRETE PRECAST BASE SECTION OR CAST IN SHELF COMPACTED SUBGRADE WITH 6" CRUSHED ROCK OR ADDITIONAL MATERIAL SUITABLE TO SUPPORT STRUCTURE 'A' 'B' 'C' 'D' 'E' 48 MH 48" 6" MIN. 5"MIN 24" MIN. 21" I D 54" MH 54" 8" MIN 5 5" MIN 24" MIN 24" 1 D 60" MH 60" 8" MIN 6" MIN 1 42" MIN 30" 1 D NOTES. 1 STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED 2 MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE IN CONFORMANCE WITH ASTM C-478. 3 ADJUSTMENT OF THE CASTING TO GRADE SHALL BE PER STD PLAN 106 THE USE OF SHIMS IS PROHIBITED, 4 SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, FACTORY -COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING, WASSER MC-SHIELDCOAT 100 OR APPROVED EQUAL, COLOR OF COATING SHALL BE WHITE 5 RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443 6 CHANNEL WIDTH AND HEIGHT SHALL EQUAL THE INSIDE DIAMETER OF THE LARGEST PIPE 7 CONNECTIONS TO MANHOLE SHALL BE MADE USING KOR-N-SEAL BOOTS OR APPROVED EQUAL 8 IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12" ABOVE FINISHED GRADE OR MUST HAVE AN AT -GRADE, MINIMUM 2'-WIDE CONCRETE RING POURED AROUND THE COVER IN PAVED AREAS, COVER MUST SLOPE TO MATCH PAVING. 9 MANHOLES OVER 20' DEEP SHALL BE A MINIMUM OF 60" IN DIAMETER STD. PLAN - 400.1 M PUBLIC WORKS '°-mob R - DEPARTMENT STANDARD SANITARY MANHOLE Martin PastuCAQ� 26/202 DATE SANITARY SEWER STANDARD MANHOLE NTS 12: DocuSign Envelope ID: 7CDD88BC-C843-439E-9366-C6DBBOF8BBB7 S�OA N06I NVUOr 1SV3 RE N T O�N1111 SEWER �������Q, MAo� tN COVER & FRAME PLAN VIEW BOLTHOLES - 3 PLCS EQUALLY SPACED 120° APART ON 23 1/16" (586mm) DIA B.C. (SEE DETAIL) 25" DIA._ C635mm] 1" 3/4"25mm] C19mm7 8 3/4" 2 1/2" -- [222mm] [64mm] TYP COVER SECTION VIEW 26 112" DIA [673mm] 25 1/4" DIA C641mmI 1/4" (6mm) DIA C27mm] NEOPRENE GASKET f 6 [151 mm] 5/8" 23 3/8" DIA CL OPEN 116mm] 1594mm] 27 5/16" DIA C694mm] 34 1/8" DIA COVER BOTTOM VIEW BLT SOC. (ALLEN HEAD) 5/8"-11 X 1.5 SS RUBBER WASHER BOLTING DETAIL 1/4" 1 1/16" C6mm] C27mm] C3mm] [R3mm] GASKET GROOVE DETAIL C867mm] NOTES: FRAME SECTION VIEW 1. ALL COVERS SHALL BE LOCKING LID PER EAST JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL. 2. USE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), SANITARY (SPECIFY "SEWER"), OR WATER (SPECIFY "WATER"). STD. PLAN - 401 V40 VPUBLIC WORKS PP" D: DEPARTMENT MANHOLE FRAME AND COVER GAZ 9/11/2019 1 Public WmYs Adminisnamr DATE :12 PI TESTING CONNECTION POLYPIG STATION PER STD PLAN 300.7 (1) VERTICAL CROSS (MJxFL) (1) BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG (1) BLIND FLANGE ON BOTTOM (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH TEMPORARY THRUST BLOCKING �10+� WATER MAIN EXISTING TEE, CAP, PLUG, OR DEAD END LINE, DO NOT DISTURB BLOCKING PUBLIC WORKS DEPARTMENT NEW DI WATER MAIN TEMPORARY BLOCKING FINAL CONNECTION UPON COMPLETION OF POLYPIGGING, HYDROSTATIC TESTING, AND DISINFECTION, REMOVE TEMPORARY THRUST BLOCKING AND TEMPORARY BLOW -OFF ASSEMBLIES FINAL CONNECTION (BY CITY FORCES) (1) DI SPOOL (1) LONG BODY DI SLEEVE (MJ) NEW DI WATER MAIN NOTES: 1. ALL CONNECTIONS TO EXISTING WATER MAINS WILL BE CONDUCTED BY CITY FORCES AS SPECIFIED IN SECTION 5-14.2 OF THE CITY OF RENTON WATER UTILITY CONSTRUCTION STANDARDS 2. LONG BODY DI SLEEVE FOR CONNECTION FROM DI TO DI PIPE AND FROM DI TO Cl PIPE WITH SAME OUTSIDE DIAMETER 3. LONG BARREL COUPLING FOR CONNECTION FROM DI TO Cl PIPE WITH DIFFERENT O.D. AND FROM DI TO AC OR TO STEEL PIPE STD. PLAN - 300.4 CONNECTION TO WATER MAIN APPROVED: EXISTING TEE OR END LINE CAP I DATE CONNECTION TO WATERMAIN MANHOLE FRAME AND COVER 2 EXISTING TEE OR END LINE CAP 3 NTS - NTS C7.10,`C7.12,, C7.13 V w-43631 1 s-43631 1 S. IN COMPLIANCE WITH CITY OF RENTON STANDARDS WATER UTILITY DEVELOPMENT ENGINEERING Jq)ff �Valdez 12/18/2025 '_� HBray 12/31/2025 • Call 811 39847 1601 5th Avenue, Suite 1600 • • two business days �o�, �ECISTEg�� 4 Seattle, WA 98101 WASTEWATER UTILITY before you dig SSIONAL E��l 206.622s822 www.kpff.com jStowell 01 /02/2026 12/09/2025 SURVEYED: SCALE. DATE: HORIZONTAL HAD 1983/1991 CITY OF SOLERA TOWNHOMES 05/30/202, 2 CIVIL CONSTRUCTION PERMIT - 3RD SUBMITTAL JSF 12/8/2025 JSF DESIGNED:MDR 2842 NE SUNSET B LV D FIELDBOOK: / / DRAWN: RAG RENTON RENTON, WA 98056 WING NO: 1 CIVIL CONSTRUCTION PERMIT - 2ND SUBMITTAL JSF 08 31 2025 JSF 0 CIVIL CONSTRUCTION PERMIT MDR 05/27/2024 JSF CHECKED: ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept. C7.20 IF NOT ONE ISEWER & WATER DETAILS NCH NO. REVISION BY DATE AP P R APPROVED:S F SCALE ACCORDINGLY SH�40 OF. 55 co ti cM O O Ln N U