Loading...
HomeMy WebLinkAboutW-436315NW 1/4 OF NW 1/4 & THE NE 1/4 OF NW 1/4 SEC 9, TWN 23 N, RGE05E,W.M. 3 vi a O N I d 0 U L c 0 U U i c 21 .N a> 0 0 a i N 0 a_ a> F— O L C 3 0 0 0 co co N O CIA 0 N O O O O N N Lill .i W x ti E :_ O CD N O 0 co C-O co 0 w W 75 O 2 Z O rUj z J r - IN UNIMPROVED ROW, O w INSTALL METER BOX d AT PROPERTY LINE WITH /i ^ a 1" COPPER TAILPIECE MAIN SIDEWALK FINISHED GRADE 9" TO 12" a� " TD 30 22 �/2° 1 LOOP DOWN TO CENTERLINE OF WATER MAIN TO PROVIDE SLACK IN SERVICE LINE TO METER MATERIALS OA CORPORATION STOP OB TUBING OC METER SETTER OD WATER METER OE METER BOX OF COUPLER AND PLUG OG GRAVEL z FI w CITY PRIVATE d y O a PIPING PIPING I I I I I 1" BALL CORPORATION STOP WITH BALL VALVE, AWWA TAPERED THREAD (CC) INLET, QUICK JOINT OUTLET, FORD FB1000-4-Q-NL OR A.Y. MCDONALD 74701BQ 1" TYPE "K" SOFT COPPER TUBING 1" SETTER, QUICK JOINT INLET AND OUTLET, PADLOCK WINGS ON INLET ANGLE BALL VALVE, SINGLE CHECK VALVE ON OUTLET, FORD VBH74-15W-44-44-Q-NL, A.Y. MCDONALD 721-415WCQQ44, OR MUELLER B-24701-6AN, INSTALL CENTERED AND SQUARED IN METER BOX, PROVIDE ADAPTERS FOR 5/8"x3/4" METERS AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BY THE CITY METER BOX, ARMORCAST A6001946PCX18, WITH METER BOX LID, ARM ORCAST A6001969RCI-H7, TO READ "RENTON WATER" COUPLER (PACK JOINT x PACK JOINT), FORD C4#-4#-Q-NL, WITH 1" GALVANIZED PLUG IF SERVICE LINE TO PROPERTY IS TO BE INSTALLED IN THE FUTURE 1 1/4" WASHED GRAVEL • PUBLIC WORKS �. DEPARTMENT FROM METER TO BUILDING NOTE: 1. WHERE THE PRV ASSEMBLY IS INSTALLED ON AN EXISTING SERVICE, THE EXISTING SERVICE SHALL BE CUT AND NEW COPPER TUBING AND BRASS FITTINGS SHALL BE INSTALLED AS REQUIRED. MATERIALS OPRESSURE REDUCING PRV ASSEMBLY WITH INTERNAL BYPASS AND STRAINER, ZURN WILKINS 600XL SERIES OR EQUAL (FNPT) VALVE ASSEMBLY OB PIPE BRASS NIPPLE (MNPT), LENGTH TO FIT OC SHUTOFF VALVE BRONZE BALL VALVE, ZURN WILKINS 850XL SERIES OR EQUAL (FNPT) OD BEND 90- BRASS BEND (FNPT x PACK JOINT) PIPE TYPE "K" SOFT COPPER TUBING, LENGTH TO FIT OF BEND 90- BRASS BEND (PACK JOINT x PACK JOINT) OG BOX AND LID 13N24" BOX AND LID, CONCRETE POLYMER OR HDPE �H GRAVEL 1i/4" WASHED GRAVEL OI PVC PIPE PVC NIPPLE, LENGTH TO FIT STD. PLAN 320.1 APPROVED: • PUBLIC WORKS 1" WATER SERVICE '• ` DEPARTMENT 6/28/2023 Martin Pastucba DATE Public WorWAdmin"tratar INDIVIDUAL PRESSURE REDUCING VALVE ASSEMBLY (RESIDENTIAL) STD. PLAN - 340.4 INDIVIDUAL PRESSURE REDUCING VALVE ASSEMBLY (RESIDENTIAL) NTS • Call 811 • • two business days before you dig 2 CIVIL CONSTRUCTION PERMIT - 3RD SUBMITTAL 1 CIVIL CONSTRUCTION PERMIT - 2ND SUBMITTAL 0 CIVIL CONSTRUCTION PERMIT NO. REVISION DATE w Z J < >- LL W 00 DIRECTION OF FLOW O 3" E1.1 O (MIN.) I 6" MIN. 6"MIN.(TYP.) UNION (TYP.) PLAN / Q 3"MAX. Z_ 00 Z_ O O 6"MIN. o �o O TO CITY METER STACKED METER SECTION 6" MIN. FREE BOXES DRAINING GRAVEL NOTES: 1. ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOW PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE DCVA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE DCVA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE DCVA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UTILITY CROSS -CONNECTION CONTROL SPECIALIST, FAX NO. 425-430-7241. 4. DCVA AND METER BOX SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. o 3 " TO 2" DOUBLE CHECK VALVE STD. PLAN - 340.8 a PUBLIC WORKS DEPARTMENT ASSEMBLY FOR IRRIGATION OR RESIDENTIAL FIRE SPRINKLER MARCH 2O10 3/4" TO 2" DOUBLE CHECK VALVE ASSEMBLY SURVEYED: ZLN DESIGNED: MDR JSF 12/8/2025 JSF JSF 08/31/2025 JSF DRAWN: RAG MDR 05/27/2024 JSF CHECKED: MNF BY DATE APPR APPROVED: JSF NTS 12/09/2025 90' BEND CAP / PLUG TEE 45' BEND 22 %2 BEND 11 Y40 BEND MINIMUM BEARING AREA AGAINST UNDISTURBED SOIL (SF) PIPE SIZE PR(PS) O O O O O 4" 200 2/(1) 1/(NONE) 1/(NONE) NONE NONE 300 3/(2) 2/(2) 2/(1) 1/M NONE 6" 200 4/(3) 3/(2) 3/(1) 1/(1) 1/(NONE) 300 6/(4) 4/(3) 3/(2) 2/(1) 1/(NONE) W. 200 7/(5) 5/(3) 4/(3) 2/(2) 1/M 300 11/(8) 8/(5) 6/(4) 3/(2) 2/(1) 10" 200 11/(8) 8/(6) 6/(4) 3/(2) 2/(1) 275 16/(11) 11/(7) 9/(6) 5/(3) 3/(2) 12" 200 16/(11) 11/(8) 9/(6) 5/(3) 3/(2) 250 24/(16) 17/(11) 13/(9) 7/(5) 4/(3) 14" 200 22/(13) 16/(11) 12/(8) 6/(4) 3/(2) 250 33/(22) 23/(16) 18/(12) 9/(6) 5/(3) 16" 200 29/(19) 21/(14) 16/(11) 8/(6) 5/(3) 225 32/(21) 23/(16) 17/(12) 9/(6) 5/(3) 18" 200 36/(24) 26/(17) 20/(13) 10/(7) 5/(4) 20" 200 45/(29) 32/(21) 24/(16) 13/(8) 7/(4) 24" 200 64/(43) 46/(30) 35/(23) 18/(12) 9/(6) * VALUES BASED ON SAFE BEARING LOAD OF 2,000/(3,000) PSF SOIL TYPE MUCK OR PEAT SOFT CLAY SAND SAND AND GRAVEL CEMENTED WITH CLAY HARD SHALE SAFE BEARING LOAD (PSF) 0 1,000 2,000 3,000 4,000 10,000 NOTES: 1. MINIMUM BEARING AREA MUST BE ADJUSTED FOR PIPE SIZE, PRESSURE, AND SOIL CONDITIONS. 2. FITTINGS SHALL BE POLYWRAPPED PRIOR TO POURING CONCRETE BLOCKING. 3. CONCRETE BLOCKING SHALL BE CAST IN PLACE AND SHALL HAVE A MINIMUM OF 0.25 SF BEARING AREA AGAINST THE FITTING. 4. CONCRETE BLOCKING SHALL BEAR AGAINST FITTINGS ONLY AND SHALL BE CLEAR OF JOINTS TO PERMIT TAKING UP OR DISMANTLING JOINT. 5. CONTRACTOR SHALL INSTALL BLOCKING ADEQUATE TO WITHSTAND FULL HYDROSTATIC TEST PRESSURE AS WELL AS TO CONTINUOUSLY WITHSTAND OPERATING PRESSURE UNDER ALL CONDITIONS OF SERVICE. 6. ALL CONCRETE SHALL BE MECHANICALLY MIXED. JOB SITE MIXING, HAND -MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. 7. IN MUCK OR PEAT, ALL THRUSTS SHALL BE RESTRAINED BY PILES OR TIE RODS TO SOLID FOUNDATION OR MUCK OR PEAT SHALL BE REMOVED AND REPLACED WITH BALLAST OF SUFFICIENT STABILITY TO RESIST THRUST. 8. CONCRETE BLOCKING SHALL BE LEFT OPEN OR SHEETED FOR MINIMUM 24 HOURS. STD. PLAN - 330.2 PUBLIC WORKS CONCRETE BLOCKING APPROVED: DEPARTMENT FOR HORIZONTAL FITTINGS 6/28/2( Marlin Pastuda DATE wain worw Aemmtstmor 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.knff.com HGRIZOWA N D 1983/1991 • CITY OF RENTON ONE INCH DATUM • AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY CONCRETE BLOCKING FOR HORIZONTAL FITTINGS NTS vv-43631 5 s-43631 5 IN COMPLIANCE WITH CITY OF RENTON STANDARDS WATER UTILITY • DEVELOPMENT ENGINEERING JValdez 12/18/2025 HBray 12/31/2025 Fmul SOLERA TOWNHOMES 2842 NE SUNSET BLVD RENTON, WA 98056 SEWER & WATER DETAILS DATE: 05/30/202 PAGE: DRAWING NO: C7.24 SHEET:OF: 44 55 co ti M O O Ln N U