HomeMy WebLinkAboutS-435304M In IV N 0- i i I I I I I I I N M II II II I I I I I I II PROPOSED 6" PVC SIDE SEWER MAIN SEEE COR. STD. 406.2 (UNDER SEPARATE PERMIT) PROPOSED 48" MANHOLE STA.0+00 (N: 5375.0027, E: 5270.4968) RIM=319.50 IE=310.62 SEE COR. STD. 400.1 & 401.1 i I/ I I I I I I I I I I I I I ILU U) O I I 2 c� I Z 1 P \ cn \ W N FF=322.7 \ CONNECT WITH \ EXISTING HOUSE SEWER 1 1 IE=319.0 I I WIN ra- Oro Know what's below. Call before you dig. 2' CONCRETE RING PER NOTE 8 ON STD 400.1 CLEAN OU IM=318.50 / IE=31 .0 / i SEE COR.STD.406.1 i I I 1.5' COMPACTED CSBC 0 95% COMPACTION / SEE WSDOT. SPEC 9-03.9(3) PROPOSED 8" DIAM. PVC SEWER MAIN EXISTING HOUSE EXISTING CO. STA.1+115.0 i (N:5374.7190, E: 5385.4971) \ RIM=317.52 EXISTING 8" PVC SEWER MAIN GARAGE - IE=310.16 6" TEMPORARY ROLLING CURB FF=320.9 / _ U CONNECT TO EXISTING 8 SEWER MAIN FOR TESC EXISTING 56" MANHOLE CONTRACTOR SHALL FIELD VERIFY I o THE EXISTING IE PRIOR TO CONSTRUCTION RIM=315.69 ,N,S)=309.92 g RETORATION LIMIT PROPOSED 15' EAS ENT ._B- - 66L = 6� �- - - - - - - - - �- - - - - - -. - - - - - - - - x 7- - Bp--.BPSBP--BP tB�=_-BP. BP - - 'BP -.- BP _BP.- ggpp-' �/� 8 -.BP _ _ BCL _ BCL .- - BC. - BCL - -.BCL - - �CL -. ftL - ZtL �L- .�L = _ I - I J _--_ - BCL - BOL - - BP r BP _ B vJ _ _ _ _ _ _ _ _ _ _� - - L BCL - - BCL - BC - - �CL _ - BCL - - I L. _. _ oI - -\ - - - -. - BCL _ BP - - - - - - - BCL - - - - . - - - - - - - - - - - - _ - - - - - - - - - - - - -. - - � - 'BCL -. BCC � CL� - 8 L - -\�CL ._ - BCL -.- BCL -. BCL - 8CL _ _ .BCC _ I I �� S S ee i I BCL. 1� I { I I - \ I S S- j I G--G--G= -G --G-G-T"G.--G. G-=G.=-/ =_ CO G --.G - L.G - G---------.----.------------------------.----- ----=� ----G G--------------�= hO¢-G- +� c--GGss=G =G� c-� G -- _wXw -w--. --wow--w--w--w--w--w--w--w-- --.--w.--w-- - -- -- X -- X -- ---X--'w- w -w- - ----r-w-.\/_ / . - w w w w w w \ >� TORATION LIMIT - - --- - ------ \- \ ---w--w--w--w--w--w- w--w-- --w- �. RE MI � _ � _ I � - - .- -. - - - - - .- - - - - - - - - - - - - - - - - - HEDGE - - - - - - - - - - - - - - - - - - - -- - -k - - - - - - - - - - I� �- G7 ST -- ST X,.... _� SILT FENCE ` ST SEE COR STD. PLAN 214.00 FOR DETAILS INLET PROTECTION oa°Ia SEE COR STD. PLAN 216.30 FOR DETAILS o\ o o I I PROPOSED 41 MANHOLE RIM=319.50 / IE=310.62 ADJUST INVERT AS NEEDED TO MATCH PIPE SLOPE. GRAVEL AREA O 6" COMPACTED CSTC 95% COMPACTION SEE WSDOT. SPEC 9-03.9(3) / GRAVEL BACKFILL SEE WSDOT. SPEC 9-03.12(4) ROADWAY TRENCH RESTORATION DETAILS LEGEND EXISTING WATER MAIN EXISTING UNDERGROUND POWER LINE EXISTING GAS LINE EXISTING OVERHEAD POWER LINE EXISTING SEWER MAIN PROPOSED SIDE SEWER LOT LINE 6" TEMPORARY ROLLING CURB FOR TESC (PROPOSED EASEMENT LIMIT RETORATION LI NTS - BP - - BP - - BP - - BP - - BP - G - - G - - G - - -OP- -OP- -OP- - - S S S S -X X X X > O Ni I h� al Ve. RT S O y mw IL 40 fiS/O\AL0. N0. - 10 5 0 10 20 co SCALE IN FEET EXISTING HOUSE GARAGE FF=317.6 3" CONTRACTOR SHALL MAINTAIN ACCESS FOR ALL RESIDENTS DURING CONSTRUCTION. JLV - - EXISTING SURFACE - - - - - - _ REMOVED THE - - - - - _ EXISTING CO E IS MANHOLE RIM=315.69 - - IE=309.92 MH--�---I I I I I I I I I I I I � I I I 0.5% MINIMUM I I I I MATCH SLOPE OF I I EXISTING SEWER MAIN. EXISTING 8" DIAM SEWER MAIN I MH I I I I I 8" DIAM. PVC, L=115.0', S=0.4% I I I I I I I I 310 I I I CONTRACTOR SHALL FIELD VERIFY THE EXISTING PIPE IE PRIOR TO CONSTRUCTION I I I I I 0+00 NOTE: UTILITIES PER RECORD ARE FOR REFERENCE ONLY REVISION SURVEYED: DESIGNED: DRAWN: CHECKED: BY I DATE I APPR APPROVED: SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 1 +00 SEWER MAIN PROFILE VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM H: V=10' V: 1 "=2' CITY OF RENTON Planning/Building/Public Works Dept. 1 +80 S-435304 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING HBray 12/08/2025 :0] 0 WASTEWATER UTILITY jstowell 12/09/2025 DATE: 2525 RESIDENT SEWER PLAN FIELDBOOK PAGE: NO - SEWER MAIN PLAN DRAWIC-4.0 SHEET: ^ OF: 10 00 Ln O N