ADVISORY NOTES TO APPLICANT
The following notes are supplemental information provided in conjunction with the administrative land use
action. Because these notes are provided as information only, they are not subject to the appeal process for
the land use action.
Planning:
(Contact: Mariah Kerrihard, 425-430-7238, mkerrihard@rentonwa.gov)
1. RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pm, Monday through Friday unless
otherwise approved by the Development Services Division.
2. Commercial, multi-family, new single family and other nonresidential construction activities shall be
restricted to the hours between seven o’clock (7:00) a.m. and eight o’clock (8:00) p.m., Monday through
Friday. Work on Saturdays shall be restricted to the hours between nine o’clock (9:00) a.m. and eight
o’clock (8:00) p.m. No work shall be permitted on Sundays.
3. Within thirty (30) days of completion of grading work, the applicant shall hydroseed or plant an
appropriate ground cover over any portion of the site that is graded or cleared of vegetation and where
no further construction work will occur within ninety (90) days. Alternative measures such as mulch,
sodding, or plastic covering as specified in the current King County Surface Water Management Design
Manual as adopted by the City of Renton may be proposed between the dates of November 1st and
March 31st of each year. The Development Services Division’s approval of this work is required prior to
final inspection and approval of the permit.
4. A National Permit Discharge Elimination System (NPDES) permit is required when more than one acre is
being cleared.
5. The applicant may not fill, excavate, stack or store any equipment, dispose of any materials, supplies or
fluids, operate any equipment, install impervious surfaces, or compact the earth in any way within the
area defined by the drip line of any tree to be retained.
6. The applicant shall erect and maintain six foot (6') high chain link temporary construction fencing around
the drip lines of all retained trees, or along the perimeter of a stand of retained trees. Placards shall be
placed on fencing every fifty feet (50') indicating the words, “NO TRESPASSING – Protected Trees” or on
each side of the fencing if less than fifty feet (50'). Site access to individually protected trees or groups
of trees shall be fenced and signed. Individual trees shall be fenced on four (4) sides. In addition, the
applicant shall provide supervision whenever equipment or trucks are moving near trees.
7. This permit shall comply with the Bald and Golden Eagle Protection Act. The permitted is responsible
for adhering to the U.S. Fish and Wildlife Service National Bald Eagle Management Guidelines (2007) and
/or your U.S. Fish and Wildlife Service permit.
Development Engineering
(Contact: Heather Bray, 425-430-7383, hbray@rentonwa.gov)
1. See Attached Development Engineering Memo dated November 20, 2025
Renton Regional Fire Authority
(Contact: Corey Thomas, 425-276-9582, cthomas@rentonrfa.org)
Environmental Impact Comments:
EXHIBIT 20
Docusign Envelope ID: FFB6F336-7B75-4DAC-8020-35E8974E808F
ADVISORY NOTES TO APPLICANT
Page 2 of 6 LUA25-000195
1. None. Fire impact fees for educational occupancies are currently charged at the rate of $28.02 per
student. Impact fee credit will be applied for the former office use at the rate of $0.14 per square foot.
Fire Code Comments:
1. The fire flow is unchanged from the existing building.
2. Fire department apparatus access roadways are adequate as they exist.
3. An approved kitchen hood fire suppression system is required for any proposed kitchen hood
exhaust systems. Separate plans and permits required by the fire department for the installation
of the fire suppression systems.
Technical Services:
(Contact: Stephanie Rary, 425-430-6592, srary@rentonwa.gov)
1. No comments at this time.
Community Services:
(Contact: Jason Lederer, 425-430-6547, jlederer@rentonwa.gov)
1. No comments at this time.
Police:
(Contact: Sandra Havlik, 425-430-7520, shavlik@rentonwa.gov)
1. See attached Environmental & Developmental Application Review Sheet.
Building:
(Contact: Rob Shuey, 425-430-7235, rshuey@rentonwa.gov)
1. No comments at this time.
Docusign Envelope ID: FFB6F336-7B75-4DAC-8020-35E8974E808F
ADVISORY NOTES TO APPLICANT
Page 3 of 6 LUA25-000195
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: November 20th, 2025
June 20, 2011
TO: Mariah Kerrihard, Associate Planner
FROM: Heather Bray, Civil Plan Reviewer
SUBJECT: Oasis Home Daycare
4508 NE 4th Street, Renton, WA
LUA25-000195
I have reviewed the application for Oasis Home Daycare located at 4508 NE 4th Street and have the following
comments:
EXISTING CONDITONS: The site is approximately 0.46 acres and has one insurance office and single wide
accessory structure. It is fronted by private property to the north, east, and west, and NE 4th Street to the south. It
is comprised of one king county parcel number 1023059117.
WATER: The project is within the City of Renton’s water service area in the Highlands 565 Pressure Zone. The
static water pressure is approximately 67 psi at ground elevation of 410 feet. There is an existing 8-
inch Cast Iron City water main located in NE 4th St that can deliver a maximum flow capacity of 2,500
gallons per minute (GPM) (Record Dwg: W-024005). There is an existing 3/4-inch water meter and
service to the existing building.
SEWER: The project is within the City of Renton’s sanitary sewer service area. There is an existing 24-inch
gravity wastewater main located in NE 4th St (Record Dwg: S-05031B). There is an existing 8-inch
gravity wastewater main located to the north of project site (Record Dwg: S-310703). There is an
existing 6-inch PVC sewer stub connecting to the 8-inch sewer main to the north.
STORM: There is an existing 12-inch private stormwater main that runs in the east-west direction and is
located approximately in the middle of the site below the proposed outdoor storage area. The
storm system conveys a stream that drains a large upstream tributary area that includes wetlands
and floodplains.
STREETS: The proposed development fronts NE 4th Street along the south property line which is classified as
a Principal Arterial Road. The existing ROW width is approximately 84 feet.
WATER COMMENTS
Docusign Envelope ID: FFB6F336-7B75-4DAC-8020-35E8974E808F
ADVISORY NOTES TO APPLICANT
Page 4 of 6 LUA25-000195
1. Based on the review of project information submitted for the pre-application meeting, Renton Regional Fire
Authority has determined that the preliminary fire flow demand for the proposed development is unchanged
from the existing building. However, an approved fire sprinkler and fire alarm system will be required to be
installed throughout the building if the occupant load exceeds 50 students. The following developer’s
installed water improvements will be required to provide domestic and fire protection service to the
development including but not limited to the items that follow:
a. The project is not proposing a fire sprinkler system as they will not exceed the 50-student
capacity, which is conceptually acceptable.
b. At the time of land use application, the project does not propose any plumbing in the
manufactured home (trailer). As a condition of approval, the project shall cut and cap the
existing waterline going to the trailer prior to construction closeout. Alternatively, the project
may install a new 1-inch service line and 3/4-inch meter with a double check valve assembly
(DCVA) downstream of the new meter on-site.
c. Installation of a “Storz” adapter on the existing hydrants will be required, if they are not
already equipped with one.
2. A conceptual utility plan will be required as part of the land use application for the subject development.
a. The applicant has submitted a conceptual utility plan that does not address removal of the
existing water service to the trailer. Either the project will need to propose a new water meter
or show cut & cap of the water service at time of building permit.
3. The development is subject to meter installation fees based on the number and size of the meters for
domestic uses and for fire sprinkler use. Current fees can be found in the 2025 Development Fees
document on the City’s website here. Fees will be charged based on the rate at the time of construction
permit issuance.
SEWER COMMENTS
1. The project needs to CCTV the existing side sewer and provide that video to the City of Renton for review.
a. The applicant has submitted a sewer inspection report stating that the sewer service is in
perfect working order. The applicant will need to provide the CCTV video at time of building
permit submittal.
2. The existing onsite septic system will need to be decommissioned and removed in accordance with
Washington State Department of Health Requirements.
a. City of Renton has verified King County decommissioning approval of the existing septic system
which is conceptually acceptable. The applicant shall provide official approval notice from
King County at time of building permit submittal.
3. The project needs to connect to the existing 6-inch sewer stub to the north of the project site, the side sewer
shall conform to the standards in RMC 4-6-040 and City of Renton Standard Details.
a. The applicant shows an existing side sewer connection which is conceptually acceptable.
Applicant shall demonstrate that existing sewer line was installed per City of Renton Standard
406.1 and 406.2 at time of building permit application.
4. A conceptual utility plan will be required as part of the land use application for the subject development.
a. A conceptual utility plan was submitted that does not show any changes to the private sewer
service onsite. This is conceptually acceptable.
SURFACE WATER
1. A geotechnical report was not provided in the Land Use Application.
a. The scope of work does not trigger requirement to provide a geotechnical report, therefore,
this is acceptable.
2. A Preliminary Technical Information Memo dated April 9th, 2025 was submitted with the Land Use
Application. The report is based on no drainage review being required.
Docusign Envelope ID: FFB6F336-7B75-4DAC-8020-35E8974E808F
ADVISORY NOTES TO APPLICANT
Page 5 of 6 LUA25-000195
a. The scope of work does not trigger Core Requirements 1-9. The Technical Information Memo is
acceptable.
b. Aquifer Protection Area, RSWDM Special Requirement #6: The proposed project is not located
within any zone of the APA.
1. Per record drawing R-31070D there is a 100-yr floodplain located on the property which was established as
part of the Vision House Children’s Village project. Per Section 1.3.2 of the 2022 RSWDM “regulations and
restrictions concerning development within a 100-year floodplain are found in the critical areas code, RMC
4-3-050”. RMC 4-3-050.C.5.a prohibits “encroachments, including fill, new construction, substantial
improvements, and construction or reconstruction of residential structures is prohibited within designated
floodways, unless it meets the provisions of subsection G4e of this section, Additional Restrictions within
Floodways.”
a. The scope of work does not appear to be within the floodplain which is conceptually
acceptable.
2. Since the proposed project contains a flood hazard area, per Section 1.3.2 of the 2022 RSWDM “the 100-
year floodplain, and applicable floodway, shall be determined and their boundaries, together with the
boundaries of the severe and moderate channel migration hazard area (if applicable), shall be delineated
on the site improvement plans and profiles”. Therefore, a flood plain/floodway study per Section 4.4.2 of
the 2022 RSWDM is required.
a. At the time of land-use, the applicant is proposing 626 square feet of pollution generating
(synthetic turf) surface for a playground structure. The applicant shall provide a pervious
surfacing as defined in the 2022 Renton Surface Water Design Manual OR a Flood Study
meeting Special Requirement #2 Floodplain/Floodway Analysis per Section 1.3.2 at building
permit application.
3. The current City of Renton Surface Water Standard Plans that shall be used in all onsite drainage submittals.
The current City of Renton Standard details are available online at the City of Renton website.
TRANSPORTATION
1. In accordance with RMC 4-6-060, if the site improvements and/or proposed building additions exceed an
overall valuation of $175,000, the project site(s) shall be required to meet the City’s Complete Streets
Standards:
a. The applicant does not propose any street improvements as the project valuation is well
under the $175,000 threshold. This is conceptually acceptable.
2. Refer to City code 4-4-080 regarding driveway regulations.
a. The applicant is not proposing any changes to the existing driveway to the east. This project
shall replace the existing driveway that is ADA compliant per RMC 4-4-080 at time of Civil
Construction Permit Application.
b. The applicant is proposing to close the existing secondary driveway to the west which is
conceptually acceptable.
3. Undergrounding of all existing and proposed utilities is required on all frontages per RMC 4-6-090.
a. The applicant is not proposing any changes or additions to the power. This is conceptually
acceptable.
4. Sites that generate 20 or more net new peak hour trips (either in the AM peak or PM peak) are required to do
a traffic impact analysis. The trips should be calculated based on the guidelines of the current ITE Trip
Generation Manual. Refer to the attached policy guidelines for traffic impact analysis for guidelines. If the
site generates 20 or more new peak hour trips in either AM peak or PM peak, then applicant should contact
the City to get information of the locations where traffic analysis is required.
a. The applicant submitted a Trip Generation Assessment dated March 5th, 2025 by Heath &
Associates which shows less than 20 AM/PM peak trips with no further evaluation being
required which is conceptually acceptable.
Docusign Envelope ID: FFB6F336-7B75-4DAC-8020-35E8974E808F
ADVISORY NOTES TO APPLICANT
Page 6 of 6 LUA25-000195
5. Paving and trench restoration within the City of Renton right of way shall comply with the City’s Trench
Restoration and Street Overlay Requirements.
6. The development is subject to transportation impact fees. Current fees can be found in the 2025
Development Fees document on the City’s website here. Fees will be charged based on the rate at the time
of building permit issuance.
GENERAL COMMENTS
1. All existing and proposed utility lines (i.e., electrical, phone, and cable services, etc.) along property
frontage or within the site must be underground. The construction of these franchise utilities must be
inspected and approved by a City of Renton inspector.
2. Adequate separation between utilities as well as other features shall be provided in accordance with code
requirements:
a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is required
except for water lines which require 10-ft horizontal and 1.5-ft vertical.
b. The stormwater line should be minimum 5 feet away from any other structure or wall or building.
c. Trench of any utility should not be in the zone of influence of the retaining wall or of the building.
3. All civil construction permits for utility and street improvements will require separate plan submittals. All
utility plans shall confirm to the Renton Drafting Standards. A licensed Civil Engineer shall prepare the civil
plans. Please visit the Development Engineering Forms page for the most up-to-date plan submittal
requirements.
4. A landscaping plan and tree retention shall be included with the civil plan submittal. Each plan shall be on
separate sheets.
5. Additional Building Permit Applications will be required for the following:
a. Any retaining walls that exceed 4 feet in height, as defined by RMC 4-4-040.
b. Detention vaults for storm water flow control.
c. Demo of any existing structures on the project site(s).
6. Fees quoted in this document reflect the fees applicable in the year 2025 only and will be assessed based
on the fee that is current at the time of the permit application or issuance, as applicable to the permit type.
Please visit www.rentonwa.gov for the current fee schedule.