HomeMy WebLinkAboutR-4332012C'M
0
w
0
0
0
0
Z
N
C�
0
N
H
m
U)
0
N
M
IZI-
w
W
w
I
w
w o6
x m
Q I
U) U)
U op
— O
U
Q
0 O
N z
O Y
0-1
N
N
00
ABBREVIATIONS (CONT'D)
CONTR CONTRACTOR DCDA DOUBLE CHECK DETECTOR ASSEMBLY EB EASTBOUND ETC ET CETERA FHMS FLAT HEAD MACHINE SCREW
CONTV CONTROL VALVE DCM DESIGN CRITERIA MANUAL EBC EMBEDDED CONDUIT ETEL EMERGENCY TELEPHONE FHV FIRE HOSE VALVE
COR CITY OF REDMOND DCVA DOUBLE CHECK VALVE ASSEMBLY EC ELECTRICAL CONTRACTOR, END CAP, ELECTRICAL ETS EMERGENCY TRIP STATION FIN FINISH(ED)
COORD COORDINATE DCW DOMESTIC COLD WATER CONDUIT, EPDXY -COATED, ELECTRICALLY ETT ELECTRIC TRANSMISSION TOWER FIX FIXED
CORP CORPORATION DDCA DOUBLE DETECTOR CHECK ASSEMBLY COMMUTATED ETW EDGE OF TRAVELED WAY FIXT FIXTURE
CORR CORRIDOR, CORRUGATED DEF DEFLECTION ECS ENVIRONMENTAL CONTROL SYSTEM Eu UNBALANCED TRACK SUPERELEVATION (INCHES) FJ FEEDER JUMPER
COV COVER(ED) DEF JT DEFLECTION JOINT ED ELECTRIC(AL) DUCT EUH ELECTRICAL UNIT HEATER FL FLOW LINE, FLANGE
CID CONCRETE PIPE, CONDUIT DEG DEGREE EDD EXHAUST DUCT DAMPER EV ELECTRIC VAULT, ELECTRIC VEHICLES FLA FULL LOAD AMPA
CPLG COUPLING DEL DELETE EER ENERGY EFFICIENCY RATING EVP EMERGENCY VEHICLE PREEMPTION FL-# FLOURPOLYMER COATING - TYPE
CPP COMMUNICATIONS POWER PANEL DEMO DEMOLITION EF EACH FACE, EXHAUST FAN EW EACH WAY, EASTBOUND TO WESTBOUND FLEX FLEXIBLE
CPT CONTROL POWER TRANSFORMER, CONTROL POINT DESC DESCRIPTION EFAN EXHAUST FAN EWC ELECTRIC WATER COOLER FLG FLANGE
CPW-# CEMENTITIOUS WALL PANEL - TYPE DET, DTL, DETAIL(S) EFC EXPOSED FINISH CONCRETE EPDXY FIBERGLASS EWH ELECTRIC WATER HEATER FLH FLATHEAD
CR CURB RAMP, CONDUIT RISER DTLS CONDUIT EWT ENTERING WATER TEMPERATURE FLR FLOOR
CRL CANE RAIL DF DIRECT FIXATION, DRINKING FOUNTAIN EFD EXHAUST FAN DAMPER EX/EXIST EXISTING FLSH FLASHING
CRS COLD ROLLED STEEL DGA DOWN GUY ANCHOR EFF EFFICIENCY EXC/EXCAV EXCAVATION FLUOR FLUORESCENT
CS COMBINED SEWER, CURVE TO SPIRAL DH DUCT HEATER EFW EFFECTIVE FLUID WEIGHT EXF EXHAUST FAN FM FORCE MAIN
CSBC CRUSHED SURFACING BASE COURSE DHW DOMESTIC HOT WATER EG EXISTING GRADE EXH EXHAUST FMP FIRE MANAGEMENT PANEL
CSJ CONSTRUCTION JOINT, CLOSURE STRIP JOINT DHWC DOMESTIC HOT WATER CIRCULATION EGR EMERGENCY GUARD RAIL EXP EXPANSION FN FENCE
CSK CASEWORK DI DROP INLET, DUCTILE IRON, DISCRETE INPUT EHC ELECTRIC HEATING COIL EXPO EXPOSED FND FOUNDATION, FAN DAMPER
CSL CROSSHOLE SONIC LOGGING DIA, DIAM DIAMETER EHS EXTRA HIGH STRENGTH EXT EXTERIOR, EXTINGUISHER, EXTERNAL FNIC FUTURE NOT IN CONTRACT
CSM COMBINED SEWER MANHOLE DID DOOR INTRUSION DETECTOR El ELECTRICAL INTERLOCK FO FACE OF, FIBER OPTIC
CSMH COMBINED SEWER MANHOLE DIFF DIFFUSER EJ EXPANSION JOINT F FOB FACE OF BRICK
CSMT CASEMENT DIM DIMENSION EJ-# / EJC-# EXPANSION JOINT COVER TYPE FOC FACE OF CONCRETE, FACE OF CURB
CSP CONCRETE SEWER PIPE DIP DUCTILE IRON PIPE ELAST-# ELASTOMERIC COATING TYPE F FLAG POLE, FAHRENHEIT, FIX FOF FACE OF FINISH
F'c 28 DAY CONCRETE STRENGTH
CST CAST STONE DIR DIRECTION EL/ELEV ELEVATION, ELEVATOR FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR
F/R FIRE RATED
CSTC CRUSHED SURFACING TOP COURSE DISC DISCONNECT ELAST ELASTOMERIC FOIO FURNISHED BY OWNER, INSTALLED BY OWNER
F/T FIXED TERMINATION
CT CERAMIC TILE, CONICAL TEE, CURRENT TRANSFORMER DISC SW DISCONNECT SWITCH ELEC/ELECT ELECTRIC(AL) FOP FACE OF POLE
F TO F FACE TO FACE
CTB CEMENT TREATED BASE DISCH DISCHARGE ELECPBD ELECTRIC PANEL BOARD FOS FACE OF SLAB / STUD / STRUCTURE, FACTOR OF
CTR CENTER(S) DISTR DISTRIBUTION ELP EMERGENCY LIGHTING PANEL FA FIRE ALARM, FIXED ANCHOR, FLOOR ASSEMBLY SAFETY
FAAP FIRE ALARM ANNUNCIATOR PANEL
CTRL CONTROL DL DEAD LOAD EM ELECTROMAGNETIC MONITORING FOT FIBER OPTIC TRANSMISSION SYSTEM
FABX FIRE ALARM BOX
CTRLR CONTROLLER DLN DRIPLINE EMB EMBEDMENT, EMBEDDED PLATE/ITEM FOW FACE OF WALL
FAC FACILITY
CTY CABLE TRAY DMP-# DECORATIVE METAL PANEL TYPE EMER EMERGENCY FP FIRE PROTECTION
FACP FIRE ALARM CONTROL PANEL
CU COPPER, CUBIC, CONDENSING UNIT DN DOWN EMH ELECTRIC MANHOLE FPAP FALL PROTECTION ANCHOR POST
FAF FRESH AIR FAN
CU YD CUBIC YARD DO DITTO, DISCRETE OUTPUT EMI ELECTROMAGNETIC INTERFERENCE FPM FEET PER MINUTE
FAI FRESH AIR INTAKE
CULV CULVERT DOC DEGREE OF CURVATURE EMP EMERGENCY MANAGEMENT PANEL FPP FIBER OPTIC PATCH PANEL
CV CONTROL VALVE, CONSTANT VOLUME, CABLE VAULT DOE DEPARTMENT OF ECOLOGY EMR ELEVATOR MACHINE ROOM FB FLAT BAR, FORESTED BUFFER FPRF FIRE PROOF
FBO FURNISHED BY OWNER
CVLV CHECK VALVE DOIT DEPARTMENT OF INFORMATION TECHNOLOGY EMRF EMERGENCY REVERSIBLE FAN FR FROM
FBRGLC FIBERGLASS CONDUIT
CW CONCRETE WALK, CONTACT WIRE, CLOCKWISE, COLD DOM DOMESTIC EMS EMERGENCY MANAGEMENT SYSTEM FREQ FREQUENCY, FREQUENTLY
WATER DP DAMPPROOFING, DEEP EMT ELECTRICAL METALLIC TUBING FC FACE OF CURB, FLEXIBLE CONNECTION, FARE FRP FIBERGLASS REINFORCED PLASTIC/POLYMER
COLLECTION
CWA COUNTERWEIGHT ANCHOR DPR DAMPER ENCL ENCLOSURE FRT FIRE RESISTANT TREATED
CWP CEMENTITIOUS WALL PANEL DR DRIVE, DOOR ENGR ENGINEER FC-# FLUOROPOLYMER COATING TYPE FS FAR SIDE, FIRE SERVICE, FUSED SWITCH
FCC FIRE COMMAND CENTER
CWR CONTINUOUS WELDED RAIL DRN DRAIN ENTR ENTRANCE FSD FIRE SMOKE DAMPER
FCO FLOOR CLEANOUT
CWT COUNTERWEIGHT DS DOWNSPOUT, DOOR SWITCH EOP/EP EDGE OF PAVEMENT FT FOOT/FEET
FCS FIELD CONTROL SYSTEM
CW-# CURTAIN WALL TYPE DSP DRY STANDPIPE EPF ELEVATOR SHAFT PRESSURIZATION FAN FTB FLUIDIZED THERMAL BACKFILL
FCU FAN COIL UNIT
CY CUBIC YARD(S) DWG(S) DRAWING(S) EPO EMERGENCY POWER OFF FTC FIRE EXTINGUISHER/TELEPHONE CABINET
DWL DOWEL EPP EMERGENCY POWER PANEL FD FIBER DUCT, FLOOR DRAIN FTG FOOTING
D DWR DRAWER EQ EQUAL FDC FIRE DEPARTMENT CONNECTION FUR FURRING
FDCP FIRE DAMPER CONTROL PANEL
DWV DRAIN, WASTE, VENT EQNBK STATION EQUATION BACK FURN FURNISH
D DEEP, DEPTH, DUCT DX DIRECT EXPANSION EQNAHD STATION EQUATION AHEAD FDN FOUNDATION FUT FUTURE
D/W DRIVEWAY FDP FIBER DISTRIBUTION PANEL
EQPT EQUIPMENT FVE FARE VENDING EQUIPMENT
DA DISABLED E FDR FEEDER
EQUIV EQUIVALENT FVEC FIRE VALVE & EXTINGUISHER CABINET
DB DRY BULB, DIRECT BURIED, DC BREAKER FE-# FIRE EXTINGUISHER TYPE
ERER EMERGENCY BACKPACK STORAGE FVNR FULL VOLTAGE NON -REVERSING
DB DUCT, CONDUIT, DEPTH, DUCTBANK E EAST/EASTING, ELECTRICAL FEC-# FIRE EXTINGUISHER CABINET TYPE
ES EACH SIDE, EXTRA STRENGTH FW FIELD WELD
DBA DEFORMED BAR ANCHOR E/P EDGE OF PAVEMENT FF FINISHED FLOOR, FAR FACE
ESC ESCALATOR FWD FORWARD
DBH DIAMETER BREAST HEIGHT E/S EDGE OF SHOULDER FFJ FULL FEEDING JUMPER
ESL ELECTRIC STREET LIGHT FXTR FIXTURE
DBL DOUBLE Ea ACTUAL TRACK SUPERELEVATION (INCHES) ESMT EASEMENT FG FINISH GRADE R-433212
Dc DEGREE OF CIRCULAR CURVE (ARC DEFINITION) EA EACH, EXHAUST AIR FH FIRE HYDRANT
ESP EXTERNAL STATIC PRESSURE DEVELOPMENT ENGINEERING
DC DIRECT CURRENT, DISTRIBUTION CABINET EAT ENTERING AIR TEMPERATURE FHC FIRE HOSE CABINET
EST ESTIMATED msippo 11/25/2025
DESIGNED BY: SCALE: DRAWING No.:
E. GOLLER ��ATHL��� Q J NTS STRIDE BUS RAPID TRANSIT
DRAWN BY: �C�� ` �t�y RIDEU FILENAME: SOUTH RENTON TRANSIT CENTER BT120-GZN002
co co
U1
C. SAXE w z5 w _j S1-BT120-GZN001-005 BT105 FACILITY ID:
CHECKED BY: BRT General Engineering Consultant J " SOUNDTRANSIT CONTRACT No.: GENERAL BT120
p 535 0 �w
M. FOLWELL �GrsTEg� �� RTA/CN 0205-24 SHEET No.: REV:
[No
12/10/2024 EDG LDG JKH ISSUED FOR BID APPROVED BY: �SIONAL SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE: GENERAL ABBREVIATIONS
012 0
DATE DSN CHK APP REVISION J. HARPER 12/04/2024 R. PARGAS 112/10/2024 J. ALTCHECH 112/10/2024 12/10/2024
co
T
N
O
O
N
CU
H
H
H
N
d
m
co
N
O
O
O
4
N
Q
J