HomeMy WebLinkAboutR-4332050N
co
Xrefs:
co
xS1-BT120-VRX
xS1-BTP120-VS
xS1-BT120-CPP(O
xBRT-CUD05-T
xS1-BTP120-GZ
xS1-BT120-CAP
xS1-BT120-CMP
0
xS1-BT120-CTP
1 1
xS1-BT120-CTN
Uj
GB-SEAL-SS56
xS 1-BT120-CD P
xS1-BT120-RPP001
xS1-BT120-CZN002
®R
CD
0
U
6
N
m
co
CD
N
CIO
It
0
0
O
0
z
J
U)
z
O
z
IY
m
C�
Y
U U)j
C m
y
Q
U m
— O
U
Q Q
N (�
z
Y
O>
N
o 0-
o U
p O m\
G \ \ rn
\ m r:70 r
\ p � �m \ \ I \ m \ �~ �~
ytirnrnN�iZ5
N10
p,
--rj"i zwn
O00 Ogoo
it,o o (3)
cfloN
V �
\ O — E -PSE — ELF
m __3 �
1 IF
c
OF y� � rn
___ __ -
—Z \— — PS9 GA9°
_ _�qs
coMCAsr — IF
F�ti��
o m I �,
\ I I o m ss ----} ss " Z � � RF��
\ O \ \ \ \\ m I 10
,�N \ I N?v L --A N)--i __SS
W---- W--L—� W— -- W-----tea---AA \ --- Wn---t— nn� --- � I � , i °° � z / \ ---- ss --__ ss __ --__�_ ► II —
\ICI No�N
m
\ \ p I m m rN���o
o \\ \ I jlj o
RAINIERAVES
m��
o oti o
�`�\
om�
m Il l NON
' c GRADY 150+00
RAINIER 200+00 \
p rn
I I
-__ -- m _ \_ RAIN IER201+00 _-_
/
RAINIER202+00
RAINIER203+00--
n
/
- -_-
_-- _--
\ p
\It—F?a
\ RAINIER STA200+00.07 �m�tn mI 'mFfiF-n
o \ =GRADY STA150+00.02 ��°m °� \ ID
\ ti
\ ti '��,
\ �O w�N,N \ wzvoNon
owo�z
r O ry Z c6 p iv u'
cNn ~ p \ ti V � O I N p �'
W \ \ N lu N -0
S-1-e- —-
3 QEPd�T6f l— 3
O obi ti O m c�
'Nn�nnnZ
-6-6��r� r
W knknlluj �? w rvy
O `" I I p p a�
0 �. 00
1p V � .p Oo
_ 12"w -t
IIIL— WI-12-� - — _� - 2-—''14-�— - N
fcn ---- rpp � N �' W
Q „8 5
_ _ _ N
() C p \ � ° of .�
U, FO
\ p
WC — SD 0 \ \A,
p4
L
MATCHLINE:
SEE DWG BT120-CTP205
LEGEND:
SF
SF
m
.� LLI
Q
= LLI
co
p INLET PROTECTION
SILT FENCE
o CONSTRUCTION FENCE
STABILIZED CONSTRUCTION ENTRANCE
�, �, �, �, �, �, �, �, �, �, �, CONCRETE WASHOUT AREA
GENERAL NOTES: KEY NOTES:
CONSTRUCTION PHASES:
1. CONTRACTOR SHALL MAINTAIN AND ADJUST O WHERE CURB INLETS ARE PRESENT, INSTALL INLET
TEMPORARY EROSION AND SEDIMENT CONTROL PROTECTION PER COR STD PLAN 216.30 AND PLACE NOTE THAT THE CONSTRUCTION PHASING BELOW IS A RECOMMENDATION AND THE CONTRACTOR MAY
(TESC), AS NEEDED. SANDBAGS BARRIER UPSTREAM OF CATCH BASIN PER COR REVISE THE PHASING AS SUITABLE FOR THE PROJECT CONSTRUCTION SEQUENCE.
2. PROTECT EXISTING TREES AND SHRUBS UNLESS STD. PLAN 216.50. SEE DRAWING BT120-CTD102 AND —
NOTED FOR REMOVAL. FOR SITE PREPARATION BT120-CTD103 FOR DETAILS. PHASE 1 \C�
PLANS, SEE DRAWINGS BT120-CSP101-106, AND COMPLETE ALL DEMOLITION AND CONSTRUCTION ALONG RAINIER AVE S INCLUDE THE FOLLOWING:-
BT120-CSP201-205. • RAINIER AVE S/HARDIE AVE SW INTERSECTION IMPROVEMENTS. -ice'
3. PROTECT EXISTING DRAINAGE STRUCTURES SUCH • SOUTHBOUND LEFT -TURN LANE AT RAINIER AVE S/HARDIE AVE SW INTERSECTION. _
AS CATCH BASINS, MANHOLES AND PIPES UNLESS
NOTED FOR REMOVAL. SEE DRAWINGS PHASE 2 103 1
BT120-CSP101-106, AND BT120-CSP201-205. � I ,, I UPDATES TO ROW
COMPLETE ALL DEMOLITION AND CONSTRUCTION ALONG NORTH SIDE OF S GRADY WAY INCLUDE THE I SEE SHEETS
4. FOR DRAINAGE PLANS, SEE DRAWINGS FOLLOWING: ► BT120-RPP101-BT120-RPP102
BT120-CDP101-106, AND BT120-CDP201-205. • ROADWAY ( TWO WESTBOUND LANES) AND DRAINAGE IMPROVEMENTS. BT120-RPP1 05-BT120-RPP1 06
5. CLEARING LIMITS IN LANDSCAPING AREAS WITHIN • SIDEWALK AND LANDSCAPE AREA. 102 201 - 107 BT1 20-RPP201 -BT1 20-RPP205
THE PROJECT LIMITS SHALL BE DELINEATED WITH
>,. o s 202 106
SILT FENCE INSTALLED AT A 2-FOOT OFFSET FROM PHASE 3
THE INSIDE OF THE CHAIN LINK FENCE EXCEPT AT COMPLETE ALL DEMOLITION AND CONSTRUCTION WITHIN THE LAKE AVE S INCLUDE THE FOLLOWING: 203 �� 204 -
DRIVEWAY AND SIDEWALK LOCATIONS. • TRANSIT CENTER EAST ENTRANCE/EXIT CONNECTION TO LAKE AVE S. 205
6. AT A MINIMUM, DISTURBED AREAS SHALL BE • ROADWAY AND DRAINAGE IMPROVEMENTS. 105 N
SODDED OR SEEDED AND MULCHED TO ENSURE .
SIDEWALK AND LANDSCAPE AREA. 101 104
THAT SUFFICIENT COVER WILL DEVELOP SHORTLY _
AFTER FINAL APPROVAL. CONCURRENT TO CONSTRUCTION PHASES S
7. USE WSDOT STANDARD SPECIFICATIONS UNLESS WA
COMPLETE ALL DEMOLITION AND CONSTRUCTION WITHIN THE PROJECT SITE INCLUDE THE FOLLOWING: I 20 10 0 20 40
OTHERWISE NOTED. • SRTC ZONE A - TRANSIT CENTER.
8. AN ADMINISTRATIVE ORDER WAS ISSUED WITH THE • SRTC ZONE B - BUS LAYOVER AREA.
NPDES CONSTRUCTION PERMIT FOR THE PROJECT. • SRTC ZONE C - INTERNAL ACCESSES, SIDEWALK, BIORETENTION SWALE AND LANDSCAPE AREA. KEY MAP SCALE IN FEET
STORMWATER TREATMENT AND SAMPLING IS • SURFACE PARKING AREA.
DEVELOPMENT ENGINEERING u
REQUIRED AS PART OF THE PERMIT. SEE NPDES R-433250 msippo 11/25/2025
PERMIT WAR314062 FOR DETAILS.
DESIGNED BY: SCALE: DRAWING No.:
S. SRIDHARAN ���� SRI Q J 1"-20' STRIDE BUS RAPID TRANSIT
BT120-CTP101
DRAWN BY: y� : U FILENAME: SOUTH RENTON TRANSIT CENTER
c) cn
4S
H. ONG INCORPORATEDCONSULTING �u S1-BT120-CTP101-106 BT105 FACILITY ID:
CHECKED BY: o ®)� BRT General Engineering Consultant � LL SovN�TRaNs�r CONTRACT No.: CIVIL BT120
1 06/13/2025 SS RP SS ADDENDUM #1 R. PARISH°�� SST �7 RTA/CN 0205-24 SHEET No.: REV:
I ��� TESC PLAN
0 12/10/2024 SS RP SS ISSUED FOR BID APPROVED BY: AL SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE: 050 1
No. DATE DSN CHK APP REVISION S. SRIDHARAN 6 9 2025 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 RAINIER STA 200+00 TO RAI N ER STA 204+00
c'7
N
T
O
N
CU
C'7
O
O
i
N
Q
J