HomeMy WebLinkAboutR-4332058N co Xrefs: xS1-BT120-VSF xS1-BTP120-CP xBRT-CUD05-T O xS1-BT120-GZK xS1-BTP120-CA xS1-BT120-CGP xS1-BT120-CMP 0 xS1-BT120-CTP 1 1 xS1-BT120-CTN GB-SEAL-SS56 xS 1-BT120-CD P xS1-BT120-RPP001 xS1-BT120-VRX001 xS1-BT120-CZN002 ®R 0 N 0 N p 0 N m co 0 N It 0 0 O U c� z J U) z O U z ry O m U� C� Y C� U)j CO U m —O U Q¢ � O _ z_ O 04 o U e i MATCHLINE: SEE DWG BT120-CTP201 Or= V VV V n 1 1 Lv-V 1 rLVj GENERAL NOTES: KEY NOTES: KEY NOTES: 1. CONTRACTOR SHALL MAINTAIN AND ADJUST TEMPORARY EROSION AND SEDIMENT CONTROL (TESC), AS NEEDED. 2. PROTECT EXISTING TREES AND SHRUBS UNLESS NOTED FOR REMOVAL. FOR SITE PREPARATION PLANS, SEE DRAWINGS BT120-CSP101-106, AND BT120-CSP201-205. 3. PROTECT EXISTING DRAINAGE STRUCTURES SUCH AS CATCH BASINS, MANHOLES AND PIPES UNLESS NOTED FOR REMOVAL. SEE DRAWINGS BT120-CSP101-106, AND BT120-CSP201-205. 4. FOR DRAINAGE PLANS, SEE DRAWINGS BT120-CDP101-106, AND BT120-CDP201-205. 5. CLEARING LIMITS IN LANDSCAPING AREAS WITHIN THE PROJECT LIMITS SHALL BE DELINEATED WITH SILT FENCE INSTALLED AT A 2-FOOT OFFSET FROM THE INSIDE OF THE CHAIN LINK FENCE EXCEPT AT DRIVEWAY AND SIDEWALK LOCATIONS. 6. AT A MINIMUM, DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. 7. USE WSDOT STANDARD SPECIFICATIONS UNLESS OTHERWISE NOTED. 8. AN ADMINISTRATIVE ORDER WAS ISSUED WITH THE NPDES CONSTRUCTION PERMIT FOR THE PROJECT. STORMWATER TREATMENT AND SAMPLING IS REQUIRED AS PART OF THE PERMIT. SEE NPDES PERMIT WAR314062 FOR DETAILS. 1 06/13/2025 SS RP I SS ADDENDUM #1 0 12/10/2024 SS RP SS ISSUED FOR BID No. DATE DSN CHK APP REVISION 11 WHERE CURB INLETS ARE PRESENT, INSTALL INLET PROTECTION PER COR STD PLAN 216.30 AND PLACE SANDBAGS BARRIER UPSTREAM OF CATCH BASIN PER COR STD. PLAN 216.50. SEE DRAWING BT120-CTD102 AND BT120-CTD103 FOR DETAILS. O2 INSTALL INLET PROTECTION PER COR STD PLAN 216.30. SEE DRAWING BT120-CTD102 FOR DETAILS. O3 INSTALL SILT FENCE PER COR STD PLAN 214.00. O4 INSTALL COMPOST SOCK PER WSDOT STD PLAN 1-30.40-02. WHEN COMPOST SOCKS ARE USED ON PAVEMENT, HEAVY CONCRETE BLOCKS SHALL BE USED TO PREVENT THE COMPOST SOCK FROM MOVING DURING RAINFALL/RUNOFF EVENTS OINSTALL ABOVE GRADE TEMPORARY CONCRETE WASHOUT FACILITY. SEE DRAWING BT120-CTD103 FOR DETAILS. DESIGNED BY: S. SRIDHARAN DRAWN BY: H. ONG CHECKED BY: R. PARISH APPROVED BY: S. SRIDHARAN #- SUBMITTED BY: 6-9-2025 R. PARGAS O7 INSTALL CONSTRUCTION FENCE - 6 FOOT HIGH CHAIN LINK FENCE WITH BLUE FABRIC MESH AND SOUND TRANSIT LOGO. O8 CONSTRUCTION ENTRANCE PER COR STD PLAN 215.10. SEE DRAWING BT120-CTD101 FOR DETAILS. 11 INSTALL ENTRANCE/EXIT GATE. 12 INSTALL WHEEL WASH AND PAVED CONSTRUCTION ENTRANCE PER COR STD PLAN 215.00.SEE DRAWING BT120-CTD103 FOR DETAILS. Q Q 4Sr)?IDE U U)_ co W J BRT General Engineering Consultant J LL SDUNDTRANSIT DATE: REVIEWED BY: DATE: 12/10/2024 J. ALTCHECH 12/10/2024 SCALE: 1 "=20' FILENAME: S 1-BT120-CTP201-205 CONTRACT No.: RTA/CN 0205-24 DATE: 12/10/2024 LEGEND: p INLET PROTECTION SF SF SILT FENCE ''i---i---i---i-�i�i�i�i�-i--i-�i�-i-�i • ' • • KEY MAP CONSTRUCTION FENCE STABILIZED CONSTRUCTION ENTRANCE CONCRETE WASHOUT AREA UPDATES TO ROW SEE SHEETS BT120-RPP101-BT120-RPP102 BT120-RPP105-BT120-RPP106 BT1 20-RPP201 -BT1 20-RPP205 20 10 0 20 40 SCALE IN FEET DEVELOPMENT ENGINEERING + R-433258 msippo 11 /25/2025 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 CIVIL TESC PLAN S RENTON TRANSIT CENTER DRAWING No.: BT120-CTP203 FACILITY ID: BT120 SHEET No.: REV: 058 1 N T N 0 0 N CU LO 0) 0 0 0 T N co N O O O N Q J