MATCHLINE:
SEE DWG BT120-CTP201
Or= V VV V n 1 1 Lv-V 1 rLVj
GENERAL NOTES: KEY NOTES: KEY NOTES:
1. CONTRACTOR SHALL MAINTAIN AND ADJUST
TEMPORARY EROSION AND SEDIMENT CONTROL
(TESC), AS NEEDED.
2. PROTECT EXISTING TREES AND SHRUBS UNLESS
NOTED FOR REMOVAL. FOR SITE PREPARATION
PLANS, SEE DRAWINGS BT120-CSP101-106, AND
BT120-CSP201-205.
3. PROTECT EXISTING DRAINAGE STRUCTURES SUCH
AS CATCH BASINS, MANHOLES AND PIPES UNLESS
NOTED FOR REMOVAL. SEE DRAWINGS
BT120-CSP101-106, AND BT120-CSP201-205.
4. FOR DRAINAGE PLANS, SEE DRAWINGS
BT120-CDP101-106, AND BT120-CDP201-205.
5. CLEARING LIMITS IN LANDSCAPING AREAS WITHIN
THE PROJECT LIMITS SHALL BE DELINEATED WITH
SILT FENCE INSTALLED AT A 2-FOOT OFFSET FROM
THE INSIDE OF THE CHAIN LINK FENCE EXCEPT AT
DRIVEWAY AND SIDEWALK LOCATIONS.
6. AT A MINIMUM, DISTURBED AREAS SHALL BE
SODDED OR SEEDED AND MULCHED TO ENSURE
THAT SUFFICIENT COVER WILL DEVELOP SHORTLY
AFTER FINAL APPROVAL.
7. USE WSDOT STANDARD SPECIFICATIONS UNLESS
OTHERWISE NOTED.
8. AN ADMINISTRATIVE ORDER WAS ISSUED WITH THE
NPDES CONSTRUCTION PERMIT FOR THE PROJECT.
STORMWATER TREATMENT AND SAMPLING IS
REQUIRED AS PART OF THE PERMIT. SEE NPDES
PERMIT WAR314062 FOR DETAILS.
1
06/13/2025
SS
RP I
SS
ADDENDUM #1
0
12/10/2024
SS
RP
SS
ISSUED FOR BID
No.
DATE
DSN
CHK
APP
REVISION
11 WHERE CURB INLETS ARE PRESENT, INSTALL INLET
PROTECTION PER COR STD PLAN 216.30 AND PLACE
SANDBAGS BARRIER UPSTREAM OF CATCH BASIN PER COR
STD. PLAN 216.50. SEE DRAWING BT120-CTD102 AND
BT120-CTD103 FOR DETAILS.
O2 INSTALL INLET PROTECTION PER COR STD PLAN 216.30. SEE
DRAWING BT120-CTD102 FOR DETAILS.
O3 INSTALL SILT FENCE PER COR STD PLAN 214.00.
O4 INSTALL COMPOST SOCK PER WSDOT STD PLAN 1-30.40-02.
WHEN COMPOST SOCKS ARE USED ON PAVEMENT, HEAVY
CONCRETE BLOCKS SHALL BE USED TO PREVENT THE
COMPOST SOCK FROM MOVING DURING RAINFALL/RUNOFF
EVENTS
OINSTALL ABOVE GRADE TEMPORARY CONCRETE WASHOUT
FACILITY. SEE DRAWING BT120-CTD103 FOR DETAILS.
DESIGNED BY:
S. SRIDHARAN
DRAWN BY:
H. ONG
CHECKED BY:
R. PARISH
APPROVED BY:
S. SRIDHARAN
#- SUBMITTED BY:
6-9-2025 R. PARGAS
O7 INSTALL CONSTRUCTION FENCE - 6 FOOT HIGH CHAIN LINK
FENCE WITH BLUE FABRIC MESH AND SOUND TRANSIT LOGO.
O8 CONSTRUCTION ENTRANCE PER COR STD PLAN 215.10.
SEE DRAWING BT120-CTD101 FOR DETAILS.
11 INSTALL ENTRANCE/EXIT GATE.
12 INSTALL WHEEL WASH AND PAVED CONSTRUCTION
ENTRANCE PER COR STD PLAN 215.00.SEE DRAWING
BT120-CTD103 FOR DETAILS.
Q Q
4Sr)?IDE U
U)_ co
W J
BRT General Engineering Consultant J LL SDUNDTRANSIT
DATE: REVIEWED BY: DATE:
12/10/2024 J. ALTCHECH 12/10/2024
SCALE:
1 "=20'
FILENAME:
S 1-BT120-CTP201-205
CONTRACT No.:
RTA/CN 0205-24
DATE:
12/10/2024
LEGEND:
p INLET PROTECTION
SF SF SILT FENCE
''i---i---i---i-�i�i�i�i�-i--i-�i�-i-�i • ' • •
KEY MAP
CONSTRUCTION FENCE
STABILIZED CONSTRUCTION ENTRANCE
CONCRETE WASHOUT AREA
UPDATES TO ROW
SEE SHEETS
BT120-RPP101-BT120-RPP102
BT120-RPP105-BT120-RPP106
BT1 20-RPP201 -BT1 20-RPP205
20 10 0 20 40
SCALE IN FEET
DEVELOPMENT ENGINEERING +
R-433258 msippo 11 /25/2025
STRIDE BUS RAPID TRANSIT
SOUTH RENTON TRANSIT CENTER
BT105
CIVIL
TESC PLAN
S RENTON TRANSIT CENTER
DRAWING No.:
BT120-CTP203
FACILITY ID:
BT120
SHEET No.: REV:
058 1