HomeMy WebLinkAboutR-4332129N
C'7
Xrefs: (�
xBRT-CUD05-TB
0
w
is
CD
00
I
0
co
SEE NOTE 6
0.5" MIN PER MANUFACTURER
r:- ;>
X 3 MAX :; SEE NOTE 9 ;
Q :;}::1..x.' I -BEAM SHAPED
,`'� MAX 3.25 CLEARANCE
POST - SEE NOTE 9
STEEL PICKET FENCE REMOVABLE DETAIL
NTS BT120-CPP106
* FENCE HEIGHT FOR STEEL PICKET FENCE REMOVABLE
6.0' FENCE HEIGHT = RAILAKDW 719+34.03, 17.49' LT TO LAKE STA 402+08.70, 68.94' LT
4.0' FENCE HEIGHT = LAKE STA 402+08.70, 68.94' LT TO LAKE STA 403+02.15, 43.96' LT
.41
PERFORATED METAL MESH ***
N
L6
.'
N
I -BEAM SHAPED
POST METAL MESH
U
o
„{.';.•
.:
�� STEEL PICKET FENCE
`"
` "� ''
NON -REMOVABLE
(4) 2" DIA X 6" LONG
STUDS AT PRMT
JOINT FILLER AT PRMT
AT SOG
SOG WHERE OCCURS
o INSIDE -
FACILITY SLEEVE
AREA 4" MIN WALL THK
SEE NOTE 2
SEE NOTE 5
PROPOSED
GROUND
TOP OF CONCRETE .,. lj..
POST FOOTING
SEE DETAIL A
SIDE VIEW
m
U) STEEL PICKET FENCE NON -REMOVABLE DETAIL 2
o NTS BT120-CPP204
co
o
FENCE WIDTH FOR STEEL PICKET FENCE NON -REMOVABLE
�
6.0' PANEL WIDTH = ALL LOCATIONS EXCEPT WHERE NOTED OTHERWISE
z
8.0' PANEL WIDTH = NTC STA 511 +05.00, 39.10' LT TO STA 518+13.00, 35.90' LT
z
Y
*** 8.0' FENCE HEIGHT AND METAL MESH FOR STEEL PICKET FENCE NON -REMOVABLE
v)
X
RAILKADW STA 716+57.19, 27.24' LT TO STA 716+62.29, 27.27' LT
w
RAILAKDW STA 716+57.19, 18.83' LT TO STA 716+82.17, 18.69' LT
RAILAKDW STA 716+82.17, 18.69' LT TO STA 716+82.75, 27.29' LT
wl
W
z
z
06
m
Y
�
CI
m
O
�<
`f'
z
Y
Lo
N
z
1
06/13/2025
LBR
DP
LBR
ADDENDUM #1
a
0
12/10/2024
LBR
LDG
LBR
ISSUED FOR BID
o
o
U
No.
DATE
DSN
C
REVISI(JN
DESIGNED BY:
L. REDMAN
DRAWN BY:
L. REDMAN
CHECKED BY:
L. GILBERT
APPROVED BY
��ATrA
OUTSIDE
FACILITY
AREA
HSS SHAPED
POST
PROPOSED
GROUND
/-- SEE DETAIL B
HSS SHAPED
POST
1/2" THICK 6.5" DIAMETER PLATE FOR CAMERA MOUNTING
1/2" HOLE IN CENTER OF PLATE FOR COMMUNICATIONS CABLE.
REFER TO BT120-JCD203 FOR CAMERA MOUNTING DETAIL
FENCE POST
SEE NOTE 10
PL 4" x 10" DIA
W/ HOLE FOR SLEEVE
6" THK LAYER OF
GRANULAR, FREE
DRAINING MATERIAL PIPE DRAIN
1" MIN INT DIA
STEEL PICKET FENCE
REMOVABLE POST FOUNDATION
NTS
2
U
H
m
n
t.
3
16
HSS
SHAPED
POST
NTS DETAIL BT120-JCD203
N_-�
00
FENCE POST
Q SEE NOTE 10
MAX 10" JOINT FILLER AT PRMT
AT SOG SEE BT120-JCP204 FOR
I CONDUIT SIZE AND
SOG WHERE OCCURS I QUANTITY
^ I I
D INSIDE o
FACILITY
AREA INSIDE OUTSIDE -
FACILITY FACILITY
AREA AREA z
c
HSS SHAPED HSS SHAPED
POST POST
SIDE VIEW
SIDE VIEW
-
U
N z
a
#3 SPIRAL
w
____
_ ___
(4) #4 VERT REINF
O
z
w
w
U)
=
12" DIA
c
FOUNDATION MIN
a
SEE NOTE 1
3" CLR
STEEL PICKET FENCE
NON -REMOVABLE
NTS POST FOUNDATION
1. PER MANUFACTURER WHERE MANUFACTURER 4. SEE SHEET BT120-SGD161 FOR DETAILS ON 7. THE FENCE SHALL BE ANTI-SCALE/CLIMB.
REQUIREMENTS INDICATE A LARGER FOUNDATION. NON -REMOVABLE FENCE CONNECTION TO RETAINING
WALL. 8. SEE SHEETS BT120-CPP101-106 AND BT120-CPP201-205
2. PROVIDE A STEEL SLEEVE SUCH THAT THE GAP AND SHEETS BT120-CSP101-106 FOR LOCATION OF
BETWEEN THE FENCE POST IS MINIMIZED, BUT THE 5. SEE SHEET BT120-EPD111 ELECTRICAL DETAILS FOR REMOVABLE AND NON -REMOVABLE FENCE.
POST CAN STILL BE REMOVED. DETAILS ON FENCE POST GROUNDING REQUIRED FOR
REMOVABLE FENCE. 9. FENCE ASSEMBLY SHALL HAVE A MINIMUM POROSITY OF
3. POSTS ARE CENTERED ON WALL, UNLESS 50%.
OTHERWISE NOTED. 6. CONTRACTOR SHALL PROVIDE A REMOVABLE, POSITIVE
EDEVELOPIMENT ENGINEERING �' CONNECTION BETWEEN THE ADJACENT FENCE PANELS TO 10. THE CONTRACTOR SHALL DESIGN THE FENCE POST,
1 R-43321290 1 1/25/2025 AVOID ANY DIFFERENTIAL DISPLACEMENT BETWEEN FENCE BEAMS, AND ANY FENCE ELEMENT AND THEIR
POSTS. CONNECTIONS.
SCALE: DRAWING No.:
NTS STRIDE BUS RAPID TRANSIT
< _j MrV=w
FILENAME: SOUTH RENTON TRANSIT CENTER BT120-CRD125
4b5co U)
r)?IDE F)lw J S1-BT120-CRD125-129 BT105 FACILITY ID:
BRT General Engineering Consultant z " SoUNDTRANSIT CONTRACT No.: CIVIL BT120
RTA/CN 0205-24 SHEET No.: REV:
SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE: FENCE DETAILS
129 1
R. PARGAS _ 12/10/2024 1 J. ALTCHECH 12/10/2024 12/10/2024
co
N
T
N
O
N
CU
H
H
H
N
It