HomeMy WebLinkAboutR-4332212N
C'7
Xrefs:
M
xS1-BT120-CPP
xS1-BT120-LPP
xBRT-CUD05-T
O
xS1-BT120-CLP
xS1-BT120-LPN
xS1-BT120-CDP
xS1-BT120-LHP
0
xS1-BT120-APP
1 1
xS1-BT120-VSF
xS1-BT120-LTP
xS1-BT120-CGP
dS1-BT120-CDP001
GB-SEAL-TRW21032616
ti
0
0
w
J
0
N
m
r
Cn
0
N_
co
co
It
0
0
l
w
Y
J
>a
I
w
Q m
ml
:
—o
Q?
N (�
z
o Y
O
"t �:
N 3:0
M
CD a_
N Lj No.
TREE, SHRUB, OR GROUNDCOVER
PREPARED PLANTING SOIL
SCARIFIED SUBGRADE
LEVEL WITH TOP
OF ADJACENT
CURB OR PAVING
°
I N
I
.{
I
I
IUJ
I
I
N
N
10
I I
C°
UNDISTURBED
I
I w
ILU
I I
EXIST NATIVE
SOIL OR EXIST
NATIVE SOIL
o
COMPACTED
TO 85% MAX
I��i�i���i
I
DRY DENSITY
STEP
1
STEP 2
STEP 3
STEP 4
MULCH
STEP 5
NOTES:
1. ALL DIMENSIONS INDICATE COMPACTED DEPTHS TO 85% MAX DRY DENSITY
IN SOUND TRANSIT AREAS. PREPARED PLANTING SOIL TO REMAIN
UNCOMPACTED.
2. VERIFY UTILITY LOCATIONS BEFORE SOIL PREPARATION TO AVOID ANY
CONFLICTS. PROTECT EXISTING UTILITIES AS REQUIRED.
3. MEDIUM WOOD CHIP MULCH SHALL BE INSTALLED TO A 4" DEPTH.
4. SEE DRAINAGE PLANS AND DETAILS FOR SOIL PREPARATION REQUIREMENTS
WITHIN THE BIOSWALE.
5. FOR SOIL PREPARATION REQUIREMENTS WITHIN THE TPZ OF PROTECTED
TREES, SEE SPEC SECTION 32 19 13 AND 01 56 39
STEP 1:
EXCAVATE SOIL BELOW
ADJACENT CURB OR PAVING;
AVOID UNDERMINING
ADJACENT CURB OR PAVING
BASE COURSE MATERIAL.
STEP 2:
SCARIFY SUBGRADE TO 10".
STEP 3:
INSTALL PREPARED PLANTING
SOIL IN EQUAL LIFTS OF 6".
ROTOTILL THE FIRST LIFT TO
INCORPORATE INTO THE TOP
3-4 INCHES OF THE SUBGRADE
SOIL.
STEP 4:
INSTALL TREE, SHRUB, OR
GROUNDCOVER.
STEP 5:
INSTALL 4" DEPTH MEDIUM
WOOD CHIP MULCH.
SOIL PREPARATION IN SHRUB AND GROUNDCOVER AREAS
SCALE: NTS
c��Tinni
TOP OF ROOT CROWN TO BE
FLUSH WITH FINISH GRADE
4" DEPTH MEDIUM WOOD CHIP
MULCH IN SHRUB PLANTING AREAS
FINISH GRADE PRIOR TO PLACING
MEDIUM WOOD CHIP MULCH
LIGHTLY SCARIFY ROOTBALL TO
LOOSEN ROOTS PRIOR TO PLANTING
1:1 SLOPE ON SIDES
OF PLANTING HOLE
BACKFILL WITH PREPARED PLANTING SOIL
OR TOPSOIL TYPE A, SEE NOTE 2 BELOW
UNDISTURBED EX SOIL OR SOIL
COMPACTED TO 85% MAX DRY
DENSITY; VERIFY POSITIVE DRAINAGE
PRIOR TO CONSTRUCTION
PLANTING HOLE TO BE 6" LARGER
THAN DIA OF ROOTBALL FOR
GROUNDCOVER, 12" LARGER THAN DIA
OF ROOTBALL FOR SHRUBS
1/2" PREPARED PLANTING SOIL AND
SEEDED PER SPEC SECTION 32 92 00
GRASS PAVER UNITS FILLED WITH
PREPARED PLANTING SOIL AND INSTALLED
IN ACCORDANCE TO THE MANUFACTURES
PRODUCT/INSTALLATION SHEET.
18" LAP OF GEOTEXTILE EDGES OR AS
SPECIFIED BY THE MANUFACTURE,
WHICHEVER IS GREATER
8" MIN SUB -BASE FOR
PAVER SYSTEM
GEOTEXTILE FOR PAVER SYSTEM
COMPACTED SUBGRADE
NOTE:
1. SEE SPEC SECTION 32 13 19 GRASSCRETE/GRASS PAVERS FOR ADDITIONAL REQUIREMENTS
GRASSCRETE/GRASS PAVER PAVEMENT SECTION
SCALE: NTS
1. ADD MANUFACTURER -RECOMMENDED AMOUNT OF MYCORRIHIZAL INOCULANT
2. TOPSOIL TYPE A TO BE PLACED WITHIN THE BIOSWALE. SEE BIOSWALE DETAIL IN THE DRAINAGE PLANS
SHRUB AND GROUNDCOVER PLANTING
SCALE: NTS
12/10/2024 1 TW I LF ILF I ISSUED FOR BID
DATE IDSN ICHK 1APP IREVISION
DESIGNED BY:
T. WALKER
DRAWN BY:
T. WALKER
CHECKED BY:
L. FRENCH
APPROVED BY:
L. FRENCH
SPECIFIED TRIANGULAR SPACING,
SEE PLANTING SCHEDULE
CENTER OF GROUNDCOVER
— —
OR SHRUB PLANTS, TYP
1 1/1
1/1
+1/2
+
+
+
SPECIFIED SPACING
�1
1/
1/
OTHERWISE SHOWN ON PLA SS
\ \ \
\
\
OR SCHEDULE
8
CURB, SIDEWALK
-
PI
AN
OR PAVING EDGE
SHRUB AND GROUNDCOVER LAYOUT
SCALE: NTS
Jacobs
SUBMITTED BY:
R. PARGAS
VARIES
TREE, TYP
ROOT COLLAR
MEDIUM WOOD CHIP
MULCH - 4" MIN DEPTH,
TAPER TO ROOT COLLAR
�"vAvAv.v v........j
6F.i.......V....A.A.AVA
AMlOvAVAMAVA
MAVA .AMAVAMAVA
..........vvAvAv.....
FA
TANVI .......OvAVA..
MlOvAVA
•...........'
ol�
I
;C7
TIES, DO NOT OVER
TEN
2" DIA, 8'LONG DOUG-FIR STAKE TO BE
LOCATED OUTSIDE ROOTBALL; MIN 1'
EMBEDMENT INTO UNDISTURBED SOIL
Qw
Z U
T_Z
a
Z w SIDEWALK WITH
FLUSH [If BASE COURSE,
m U SEE CIVIL DWGS
NO 111M 1 0
PREPARED PLANTING
SOIL
PREPARED PLANTING SOIL COMPACTED TO
24" DEPTH ROOT BARRIER, 90% MAX DRY DENSITY UNDER ROOT BALL
TYP. SEE NOTE 2
SLOPE AS REQUIRED TO AVOID UNDERMINING
SIDEWALK, CURB AND BASE COURSE
UNDISTURBED EX SOIL OR SOIL COMPACTED TO 85% MAX DRY
NOTES: DENSITY; VERIFY POSITIVE DRAINAGE PRIOR TO CONSTRUCTION
1. ADD MANUFACTURER -RECOMMENDED AMOUNT OF MYCORRIHIZAL INOCULANT
2. INSTALL 10 FT LENGTH OF ROOT BARRIER, CENTERED ON TRUNK OF THE TREE, WHERE TREES ARE
INSTALLED WITHIN 10 FT OF PAVEMENT
BALL AND BURLAPPED TREE PLANTING
SCALE: NTS
BUILDING WALL, SEE ARCHITECTURAL
MEDIUM WOOD CHIP MULCH, SEE SOIL PREPARATION AND
SHRUB PLANTING DETAILS
PLANTING SOIL, SEE SOIL PREPARATION AND SHRUB
PLANTING DETAILS
WEATHERING STEEL PLANTER EDGE
CONCRETE SIDEWALK
CURRENT PLANNING
jding 11 /05/2025
DEVELOPMENT ENGINEERING
-t-
msippo 11 /25/2025
•
ANCHOR ACCORDING TO MANUFACTURER'S
RECOMMENDATIONS AND SPECIFICATIONS. SEE SPEC
SECTION 32 31 56, DECORATIVE METAL
WEATHERING STEEL PLANTING EDGE
SCALE: NTS
SCALE:
Q J NTS
- Q FILENAME:
CD co
w _j S1-BT120-LPD101
BRT General Engineering Consultont z " SOUNDTRANSIT CONTRACT No.:
RTA/CN 0205-24
DATE: REVIEWED BY: DATE: DATE:
12/10/2024 1 J. ALTCHECH 12/10/2024 12/10/2024
STRIDE BUS RAPID TRANSIT
SOUTH RENTON TRANSIT CENTER
BT105
LANDSCAPE
PLANTING DETAILS
u
R-4332212
DRAWING No.:
BT120-LPD101
FACILITY ID:
BT120
SHEET No.: REV:
307 0
A
H
H
H
N
d
co
N
O
O
O
N
Q
J