HomeMy WebLinkAboutR-4332214GENERAL NOTES: Xrefs: xBRT-CUD05-TB Z_HOLD_xS1-B1 GB-SEAL-TRW2 1. THE IRRIGATION SYSTEM IS DESIGNED TO OPERATE AT WATER ` PRESSURE OF 70 PSI MINIMUM AT THE POINTS OF CONNECTION (IRRIGATION WATER METER), AND A MAXIMUM FLOW DEMAND OF 40 GPM. THE CONTRACTOR SHALL VERIFY PRESSURE PRIOR TO INSTALLATION OF IRRIGATION EQUIPMENT. IF THERE IS A DISCREPANCY, THE IRRIGATION CONTRACTOR SHALL NOTIFY THE RESIDENT ENGINEER, IMMEDIATELY, IN WRITING SO ADJUSTMENTS CAN BE MADE. 2. A PRESSURE REGULATING VALVE SHALL BE INSTALLED IF THE STATIC SERVICE PRESSURE EXCEEDS EIGHTY (80) POUNDS PER SQUARE INCH (PSI) AT THE POINT OF CONNECTION. THE PRESSURE REGULATING VALVE SHALL BE LOCATED BETWEEN THE LANDSCAPE WATER METER AND THE FIRST POINT OF WATER USE AND SHALL BE SET AT THE MANUFACTURER'S RECOMMENDED PRESSURE FOR SPRINKLERS. 3. AT RAINIER AVE & HARDIE AVE, NEW IRRIGATION IS INTENDED TO CONNECT TO AND MODIFY THE EXISTING SYSTEM IN THE MEDIAN ISLANDS AND PLANTER STRIPS. AS BUILT INFORMATION IS NOT AVAILABLE, SO CONTRACTOR SHALL VERIFY LOCATIONS OF HEADS, PIPES AND EQUIPMENT OF THE EXISTING SYSTEM. WHEN ADDING HEADS TO AN EXISTING CIRCUIT, USE NEW HEADS THAT MATCH EXISTING. WIRE NEW VALVES TO THE EXISTING CONTROLLER. CONTRACTOR TO COORDINATE ANY SHUTOFF OR REVISION OF THE EXISTING SYSTEM MINIMUM 3 DAYS PRIOR WITH CITY PARKS DEPARTMENT AND CITY PROJECT MANAGER. 4. PLANS ARE DIAGRAMMATIC. INSTALL PIPES IN PLANTING AREAS UNLESS A SLEEVE IS REQUIRED TO CROSS UNDER PAVEMENT. 5. ALL DIMENSIONS, QUANTITIES AND MATERIALS SHALL BE VERIFIED BY IRRIGATION CONTRACTOR. CONTRACTOR SHALL INSTALL ADDITIONAL HEADS, AS NEEDED, TO PROVIDE ADEQUATE COVERAGE AT NO ADDITIONAL COST TO THE OWNER. 6. THE CONTRACTOR SHALL NOT WILLFULLY INSTALL IRRIGATION AS SHOWN ON THE PLANS WHEN IT IS OBVIOUS IN THE FIELD THAT EXISTING OBSTRUCTIONS, GRADE DIFFERENCES OR DIFFERENCES IN SITE DIMENSIONS MAY NOT HAVE BEEN FORESEEN AND CONSIDERED IN THE DESIGN. THE CONTRACTOR SHALL NOTIFY THE RESIDENT ENGINEER IF SUCH OBSTRUCTIONS AND DIFFERENCES OCCUR. IN THE EVENT THAT NOTIFICATION IS NOT GIVEN THE CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR ALL NECESSARY CHANGES AT THE CONTRACTOR'S EXPENSE. 7. SLEEVES: A. ALL PIPING AND 24 VOLT WIRING PASSING UNDER PAVING OR WALLS SHALL BE SLEEVED. B. THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH THE PAVING CONTRACTOR FOR INSTALLATION OF SLEEVES. C. THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF WIRE CONDUITS FROM THE CONTROLLER TO THE MAINLINE LOCATION. 8. REMOTE CONTROL VALVES AND QUICK COUPLER VALVES SHALL BE INSTALLED ADJACENT TO WALKS OR PAVING. 9. REFER TO IRRIGATION DETAILS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. 10.TEMPORARY WATERING MEASURES FOR PLANTS AND TREES AFFECTED BY IRRIGATION SHUTOFF SHALL BE PROVIDED BY THE CONTRACTOR WITH INSPECTION BY THE CITY'S PARK DEPARTMENT PRIOR TO IRRIGATION SHUT-OFF. c� 0 0 z ry 0 N m 0 N M IZI- 0 W Y J Q i W J m Q r) �m _O �a N Z M Y N 1 06/13/2025 AK LF LF ADDENDUM #1 ©0 12/10/2024 AK LF LF ISSUED FOR BID o a o U No. DATE DSN CHK APP REVISION 1 HYDROZONE INFORMATION TABLE % of Irrigation Landscape Hydrozone Plant Type Method Area (SF) Area 1 Turf Rotary 15,702 14% 2 Shrubs&Trees Rotary 85,180 76% 3 Water Quality Swales Rotary 11,370 10% 4 Raised Planter Box Drip 120 0% Total LS Area 1 112,372 L.dnuscdLM vvd«r /A11UWd11cV LWA = (ETo) (0.62) [(0.7 x LA) ] gallons per month (July) ETo = 5.55 Reference Evapotranspiration inches per week July 0.7 = Adjustment Factor LA = 112,372 Landscape Area (sf) 0.62 = Conversion factor (to gallons per sf) LWA = 270,670 gallons per month Landscape Water Requirement LWR Where: ETo PF HA 0.62 I = = 5.55 = = = = (Eto) (0.62) [(PF)(HA)/IE] Reference Evapotranspiration inches per week July Plant factor Hydrozone Area (sf) Conversion factor (to gallons per sf) Irrigation efficiency HYDROZONE TABLE FOR CALCULATING LWR Hydrozone Plant Water Use Type Plant Type Plant Factor Irrigation Eficiency Hydrozone Area (SF) PF X HA PF X HA IE 1 2 3 4 H M M M Turf Shrubs & Trees Water Quality Swales Raised Planter Box 0.8 0.4 0.4 1 0.4 0.85 15,702 85,180 11,370 1 1201 12,562 34,072 4,548 48 14,778 40,085 5,351 1 53 0.85 0.85 1 0.9 TOTAL 1 112,372 1 1 60,267 LWR = 207,378.68 gallons per month PRESSURE LOSS CALCULATIONS: Generated: 2024-02-20 14:29 P.O.C. NUMBER: 01 Water Source Information: ON SITE FLOW AVAILABLE Water Meter Size: 2" Flow Available 70.55 GPM PRESSURE AVAILABLE Static Pressure at POC: 70 PSI Elevation Change: 5.00 ft Service Line Size: 2" Length of Service Line: 20 ft Pressure Available: 67 PSI DESIGN ANALYSIS Maximum Station Flow: 36.78 GPM Flow Available at POC: 70.55 GPM Residual Flow Available: 33.77 GPM Critical Station: 16 Design Pressure: 40 PSI Friction Loss: 4.09 PSI Fittings Loss: 0.41 PSI Elevation Loss: 0 PSI Loss through Valve: 3.53 PSI Pressure Req. at Critical Station: 48.0 PSI Loss for Fittings: 0.04 PSI Loss for Main Line: 0.44 PSI Loss for POC to Valve Elevation: 0 PSI Loss for Backflow: 11.8 PSI Loss for Master Valve: 0.53 PSI Loss for Water Meter: 1.11 PSI Critical Station Pressure at POC: 62.0 PSI Pressure Available: 67 PSI Residual Pressure Available: 5.03 PSI DESIGNED BY: A. KRINGEL DRAWN BY: A. KRINGEL CHECKED BY: L. FRENCH APPROVED BY: L. FRENCH Jacobs SUBMITTED BY: R. PARGAS IKKRjA I IUN bUHtUULt: SYMBOL MANUFACTURER/MODEL/DESCRIPTION POP-UP TURF ROTATOR - 22-30' RADIUS 41N. POP-UP WITH FACTORY INSTALLED CHECK VALVE, FLOGUARD, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ ARC 210-270, A=GRAY 360 ARC. POP-UP SHRUB ROTATOR - 31-35' RADIUS B 121N. POP-UP WITH CHECK VALVE, FLOGUARD, PRESSURE REGULATED TO 40 PSI. LB=LIGHT BROWN, ADJUSTABLE ARC, 90-210. z9a 800 A 800 F ► ► > �T M POP-UP SHRUB ROTATOR - 13-21' RADIUS 121N. POP-UP WITH CHECK VALVE, FLOGUARD, PRESSURE REGULATED TO 40 PSI. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, R=RED 360 ARC. POP-UP SHRUB ROTATOR - 22-30' RADIUS 121N. POP-UP WITH CHECK VALVE, FLOGUARD, PRESSURE REGULATED TO 40 PSI, B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ ARC 210-270, A=GRAY 360 ARC. POP-UP SHRUB ROTATOR - 6-12' RADIUS 121N. POP-UP WITH CHECK VALVE, FLOGUARD, PRESSURE REGULATED TO 40 PSI. ADJ=ORANGE AND GRAY ( ARC 90-210), 360=LIME GREEN AND GRAY (ARC 360) POP-UP SHRUB ROTATOR - 8-15' RADIUS 121N. POP-UP WITH CHECK VALVE, FLOGUARD, PRESSURE REGULATED TO 40 PSI. M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC, O=OLIVE 360. QTY PSI SYMBOL 31 40 91 40 363 40 POP-UP SHRUB ROTATOR, CORNER NOZZLE - 8-15' RADIUS 121N. POP-UP WITH FACTORY INSTALLED CHECK VALVE, FLOGUARD, PRESSURE REGULATED TO 40 PSI, MP ROTATOR 56 40 NOZZLE. T=TURQUOISE ADJ ARC 45-105. MANUFACTURER/MODEL/DESCRIPTION QTY 1W LOW FLOW DRIP CONTROL KIT 1 1IN. LOW FLOW VALVE, 3/41N. PRESSURE REGULATING RBY FILTER, AND 30PS1 PRESSURE REGULATOR. AREA TO RECEIVE DRIPLINE ON -SURFACE PRESSURE COMPENSATING DRIPLINE 123.5 L.F. 0.9 GPH EMITTERS AT 12" O.C. DRIPLINE LATERALS SPACED AT 12" APART, WITH EMITTERS OFFSET FOR TRIANGULAR PATTERN. UV RESISTANT. ,Sr.RIDE BRT General Engineering Consultant DATE: REVIEWED BY: 12/10/2024 1 J. ALTCHECH SCALE: NTS Q Lu FILENAME: Q U C/)U) w J S1-BT120-LRN101 z � SCONTRACT No.: OUNDTRANSIT RTA/CN 0205-24 DATE: DATE: 12/10/2024 12/10/2024 MANUFACTURER/MODEL/DESCRIPTION QTY REMOTE CONTROL VALVE 1", 1-1/2", 2" PLASTIC INDUSTRIAL VALVES. LOW FLOW 26 OPERATING CAPABILITY, GLOBE CONFIGURATION. WITH PRESSURE REGULATING MODULE, AND SCRUBBER TECHNOLOGY. QUICK COUPLING VALVE 0 1" BRASS QUICK -COUPLING VALVE, WITH 17 CORROSION -RESISTANT STAINLESS STEEL SPRING, LOCKING THERMOPLASTIC RUBBER COVER AND 2-PIECE BODY. Cb BALL VALVE - BRASS- LINE SIZE 6 GATE VALVE 2 My MASTER VALVE 2" 2 NORMALLY OPEN BRASS MASTER VALVE THAT PROVIDES DIRTY WATER PROTECTION. 2" SIZE. OD DRAIN VALVE 2 0 DOUBLE CHECK BACKFLOW PREVENTER 1" 1 BF DOUBLE CHECK BACKFLOW PREVENTER 2" 1 CONTROLLER - GRADY WAY MODEL TO BE DETERMINED. SHALL BE COMPATIBLE C2 WITH CITY OF RENTON REQUIREMENTS MINIMUM 2 1 STATIONS. TO BE INSTALLED IN EXTERIOR STAINLESS STEEL PEDESTAL. CONTROLLER - ON SITE SEE SPECIFICATIONS FOR MODEL. SHALL BE COMPATIBLE WITH SOUND TRANSIT SYSTEM -WIDE REQUIREMENTS ALLOWING FOR SYSTEM -WIDE © CONNECTIVITY. PROVIDES ELECTRONIC MONITORING OF THE IRRIGATION CONTROLLER TIED TO THE OMF OVER 1 THE COMMUNICATION BACKBONE USING IP TECHNOLOGIES FOR ALL NEW FACILITIES WITH THE GOAL OF CENTRALLY MONITORING FACILITY WATER USAGE. TO BE INSTALLED IN EXTERIOR STAINLESS STEEL PEDESTAL. ® RAIN AND FREEZE SENSOR 2 CONDUIT INSTALLATION, MOUNT PER DETAIL. NORMALLY CLOSED SWITCH. FS 1-1/21N. FLOW SENSOR 2 BRASS MODEL. OPERATING RANGE 4.0 GPM TO 80.0 GPM. M2 WATER METER 1" 1 SEE CIVIL PLANS M WATER METER 2" 1 SEE CIVIL PLANS POINT OF CONNECTION PI-�f EXISTING IRRIGATION AT RAINIER & HARDIE - VERIFY 1 LOCATION POC POINT OF CONNECTION 1" 1 IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 - SIZE 13,531 PER PLAN L.F. IRRIGATION MAINLINE: PVC SCHEDULE 40 - 3" SIZE 3,979 - - - - UNLESS NOTED OTHERWISE L.F. SOLVENT WELD W/THRUST BLOCKS PIPE SLEEVE: PVC SCHEDULE 40 - TWICE THE SIZE OF 1,666 PIPE L.F. Valve Callout -uu Valve Number # # a Valve Flow #" Valve Size CURRENT PLANNING jding 11 /05/2025 EOPMENT ENGINEERINGppo 11 /25/2025 R-4332214 STRIDE BUS RAPID TRANSIT DRAWING No.: SOUTH RENTON TRANSIT CENTER BT120-LRN101 BT105 FACILITY ID: LANDSCAPE BT120 SHEET No.: REV: IRRIGATION NOTES S RENTON TRANSIT CENTER 309 1 C'7 N O O 4 N Q J