HomeMy WebLinkAboutRenton Market & Piazza Civil Plan C3.01 20260212• • • • • • • • • • • • • • • • 37.8 37. 6 37 . 4 37 . 2 37 . 0 36 . 8 36 . 6 36. 8 37. 0 37. 2 3 7 . 4 37. 2 37.4 37.6 37.8 37.6 37.6 37.4 37.2 37.0 36.8 3 C3.51 1 C3.20 2 C3.20 1 C3.10 37 20+00 21+00 PARCEL #5696000050 LO G A N A V E S SP U P A R C E L #0 0 0 7 2 0 - 0 1 8 8 3 7 S 3RD ST 8" SD, TYP 17 . 9 ' ± RIGHT-OF-WAY LINE, TYP PROP LANDSCAPING, REFER TO LS PLAN, TYP PROP SITE SEATING, TYP REFER TO LS PLANS CLEAN OUT (CO) 4" IE 35.2 0UT, NE AD 10 (EXIST) ADJUST RIM TO FG PROP LIGHTING ROUTING (2)-1" PVC CONDUIT (2)-34" PVC CONDUIT REFER TO ELEC PLANS PROP LIGHTING ROUTING (2)-3 4" PVC CONDUITS (2)-1" PVC CONDUITS REFER TO ELEC PLANS INTERCEPT EXIST 3/4" CONDUIT REFER TO ELEC PLANS INTERCEPT EXIST 3 4" CONDUIT TO SERVICE PROP LIGHT REFER TO ELEC PLANS PROP ELEC ENCLOSURE REFER TO ELEC PLANS MATCH EXIST GRADES, TYP REFER TO LS PLANS FOR SOFTSCAPE GRADING, TYP AD 11 CO 4" IE 35.48 0UT, NW AD 12 PROP LIGHT POLE, REFER TO LS AND ELEC PLAN, TYP CONNECT TO EXIST CB EXIST RIM 35.58 ± 8" IE IN 33.6 ± (N) EX 12" IE IN 33.6 ± (E) EX 12" IE OUT 33.6 ± (S) SDCB 100 AD 20 AD 13 RIM 37.55± 4" IE IN 35.0 (NE) 4" IE OUT 35.0(SE) 66" SPU WATER MAIN 52" SPU WATER MAIN ELECTROLYSIS TEST STATION, PER CITY OF SEATTLE STD PLAN 360. REROUTE EXIST SPU ELECTROLYSIS TEST STATIONS CONDUIT AND WIRING TO PROP LOCATION. COORDINATE WITH SPU. PROTECT EXIST SPU CATHODIC PROTECTION RECTIFIER, TYP SD LINE 10 SD LINE 20 CONTRACTOR SHALL COORDINATE WITH SPU PRIOR TO AND DURING ANY CONSTRUCTION WITHIN THE SPU PARCEL 12" SPU WATER MAIN MATCH EXIST GRADES, TYP SOUTH ENTRY ENLARGEMENT PEDESTRIAN CONCRETE PAVING, REFER TO NOTE 7, TYP 1 C3.13 PIAZZA PARK PIAZZA PARK GRADING ENLARGEMENT WEST LIMITS OF WORK, TYP 1 C3.51 4" FRENCH DRAIN (FD), TYP SLOPE @ 0.5% MIN PROP PERMEABLE SURFACING AT EXIST TREE, TYP EXIST CONCRETE PAVING TO REMAIN, TYP PROP FLUSH CONCRETE CURB, TYP 2 C4.50 PROP PERMEABLE SURFACING AT PROP TREE, TYP 2 C4.50 PROP VEHICULAR PAVING, CONCRETE PANEL REPLACEMENT, TYP. REFER TO NOTE 6. PROP FACE OF CONCRETE TRAFFIC CURB, PER COR STD PLAN 101 1 C4.50 PARCEL #5696000055RELOCATE EXIST WATER DRINKING FOUNTAIN, LOCATE PER LS PLAN CONNECT DOMESTIC WATER, AND SS SERVICE TO EXIST ONSITE INFRASTRUCTURE. MATCH EXIST SERVICE SIZES FOR FOUNTAIN. REFER TO NOTE 2. 4.0' LO G A N A V E S SSCO, TYP 2 C3.50 EXIST 1" LS IRRIGATION WATER METER, PER COR 1" DCVA, REFER TO LS PLANS PROP ELEC POC (1) 2" PVC CONDUIT LS ELEC RECEPTACLE, CONNECT TO EXIST CONDUIT, REFER TO LS AND ELEC PLANS PROP LIGHT POLE POC, TYP ELEC JUNCTION BOX, TYPE 1 PER COR STD PLAN 119 AND 120, AND WSDOT STD PLAN J-40.10-04(1) 2" PVC CONDUIT, REFER TO ELEC PLANS PROP LIGHTING ROUTING (1) 2" PVS CONDUIT, REFER TO ELEC PLANS NOTES: 1.REFER TO C1.00 TO C1.02 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS. REFER TO C3.00 FOR CIVIL IMPROVEMENT'S LEGEND AND NOTES. 2.CONTRACTOR SHALL CONFIRM POC'S PRIOR TO CONSTRUCTION WHEN CONNECTING TO EXISTING SYSTEMS AND NOTIFY ENGINEER OF ANY DISCREPANCIES. PRIOR TO CONSTRUCTION, FIELD VERIFY DOWNSTREAM INVERTS FOR ALL EXISTING SS AND SD PIPES, AREA DRAINS AND CATCH BASINS WITH PROPOSED UPSTREAM CONNECTIONS. CONFIRM EXISTING OUTLET INVERTS PROVIDE POSITIVE DRAINAGE FOR ALL UPSTREAM PIPES. PIPES SHALL BE VERIFIED WITH DYE TEST, CCTV, OR OTHER METHOD COORDINATED AND APPROVED BY CITY OF RENTON. COORDINATE TESTING WITH CITY. CONFIRM DRINKING FOUNTAIN IS CONNECT TO EXIST DOMESTIC WATER SUPPLY PRIOR TO INSTALLATION. 3.PROJECT ASSUMES THAT ALL CITY EXISTING UTILITY INFRASTRUCTURE IS ADEQUATELY SIZED TO SUPPORT THE PROJECT. 4.PRIOR TO DEMOLITION, CONTRACTOR SHALL FIELD VERIFY AND LOCATE ALL EXISTING UTILITIES TO REMAIN WITHIN AND ADJACENT TO LIMIT OF WORK. 5.ALL EXISTING PAVEMENT STRIPING DISTURBED DURING CONSTRUCTION SHALL BE REPLACED IN KIND. PRODUCTS SHALL BE PER CITY OF RENTON PUBLIC WORKS DEPARTMENT STANDARD PLANS AND SPECIFICATIONS, AND WSDOT STANDARD PLANS AND SPECIFICATIONS. CONTRACTOR SHALL SUBMIT A PAVEMENT RESTORATION PLAN INCLUDING, CUTTING AND JOINTING, FOR ALL PAVEMENT BEING DISTURBED. 6.FULL DEPTH PAVEMENT REPLACEMENT, AND TRENCH RESTORATION AT UTILITY CUTS, SHALL BE PER CITY OF RENTON STD DETAILS. PAVEMENT SECTION SHALL BE PER CITY OF RENTON STD DETAILS, OR MATCH EXISTING WHICHEVER IS GREATER. MATCH EXISTING PAVEMENT MATERIAL PER ASSOCIATED STANDARD DETAILS. TRENCH AND BACKFILL SHALL BE PER CITY OF RENTON RENTON STD. PLAN 220.20. PEDESTRIAN CONCRETE PAVEMENT SHALL BE PER CITY OF RENTON STD. PLAN 102. VEHICULAR CONCRETE PAVING SHALL BE PER CITY OF RENTON RENTON STD. PLAN 110, 110.1 AND 111 AND PROJECT DETAILS. 7.PEDESTRIAN CONCRETE, MINIMUM SECTION: 4" CONCRETE 6" CSBC REFER TO LANDSCAPE FOR CONCRETE SCORING, COLOR, AND FINISHES. 8.THE RENTON MARKET AND PIAZZA PROJECT IS REQUIRED TO MEET STORMWATER REQUIREMENTS PER THE 2022 CITY OF RENTON SURFACE WATER DESIGN MANUAL (RSWDM). 8.1.FLOW CONTROL: THE PROJECT PROPOSES MORE THAN 5,000 SQUARE FEET OF NEW PLUS REPLACED IMPERVIOUS SURFACE AND IS LOCATED IN THE PEAK FLOW RATE CONTROL STANDARD AREA. TARGET SURFACES DO NOT GENERATE MORE THAN A 0.15-CFS INCREASE IN THE EXISTING SITE CONDITIONS 100-YR PEAK FLOW, THEREFORE FLOW CONTROL IS NOT REQUIRED. 8.2.WATER QUALITY: THE PROJECT PROPOSES LESS THAN 5,000 SQUARE FEET OF NEW PLUS REPLACED IMPERVIOUS SURFACE (PGIS), AND LESS THAN ¾ ACRES OF POLLUTANT GENERATION PERVIOUS SURFACE (PGPS), THEREFORE WATER QUALITY IS NOT REQUIRED. 8.3.ON-SITE BMPS: THE PROJECT PROPOSES MORE THAN 2,000-SF OF NEW PLUS IMPERVIOUS SURFACE, THEREFORE ON-SITE STORMWATER MANAGEMENT (OSM) IS REQUIRED. ALL AVAILABLE OSM BMP'S WERE EVALUATED AND ARE NOT FEASIBLE FOR THE SITE. 8.4.THE PROJECT IS LOCATED IN AN AQUIFER PROTECTION AREA, THEREFORE STORMWATER MITIGATION FACILITIES SHALL NOT INFILTRATE AND SHALL BE COLLECTED VIA STORMWATER CONVEYANCE AND DISCHARGE TO THE CITY MAIN. 9.GREASE INTERCEPTOR SIZE AND VAULT PER MECHANICAL. 10.ELECTRICAL SERVICE FOR THE SITE IS PER ELECTRICAL. 11.STORM, SEWER, AND WATER INFRASTRUCTURE SHALL BE PER CITY OF RENTON STANDARDS AND WSDOT STANDARD SPECIFICATIONS, UNLESS OTHERWISE NOTED. 12.STORM DRAINAGE PIPE MATERIAL SHALL BE PER RSWDM TABLE 4.2.1.A2, UNLESS OTHERWISE NOTED. 13.ALL REGULATORY SIGNAGE AND PAVEMENT STRIPING SHALL CONFORM TO CITY OF RENTON AND MUTCD SPECIFICATIONS. 14.LOCATION AND DEPTH OF EXISTING SPU WATER MAINS (TRANSMISSION PIPE LINES) IS APPROXIMATE. 14.1.SPU SHALL BE NOTIFIED AND ONSITE WHILE CONTRACTOR PERFORMS ANY CONSTRUCTION WITHIN THE SPU PARCEL. SPU SHALL BE NOTIFIED AT LEAST 3 BUSINESS DAYS PRIOR TO CONSTRUCTION. CALL NUMBER (206)-386-1800. 14.2.AN EXISTING CATHODIC PROTECTION SYSTEM IS PRESENT AT THE CROSSING LOCATION OF THE SPU TRANSMISSION PIPELINE. PROTECT EXISTING CATHODIC PROTECTION SYSTEM. 14.3.CLEARANCE BETWEEN SPU WATER TRANSMISSION PIPELINE AND PROPOSED STORM DRAIN SHALL BE 12" MIN. CONTRACTOR TO ALERT ENGINEER AND SPU IF MINIMUM CLEARANCE CANNOT BE MET PRIOR TO CONSTRUCTION. Call 811 two business days before you dig R Sheet: Sheet contents: Scale: AHJ Project No.: Project No.: Revisions: 233 Burnett Ave S. Renton, WA 98057 Renton Market & Piazza 1507 Belmont Ave, Suite 200 Seattle, Washington 98122 206.323.9932 No.:Date:Description: 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com 100% CONSTRUCTION DOCUMENTS 02/10/2025 003 0 1 inch = 10 feet 5'10'20' C3.01 CIVIL IMPROVEMENT PLAN MA T C H L I N E : R E F E R T O S H E E T C3 . 0 2 REFER TO SHEET C3.00 FOR CONTINUATION MA T C H L I N E : R E F E R T O S H E E T C3 . 0 3 003 003 003 003 003 08.08.25 ASI 001-CIVIL PERMIT CORRECTION 09.15.25005 ASI 002-CIVIL PERMIT CORRECTIONS 005 005 005 005 01.23.26013 RFI 42.2 013 2026-01-23