HomeMy WebLinkAboutT-4332027N
Xrefs: (Y�
xS1-BT120-CPPO
xS1-BT120-VRXO
xS1-BT120-CDPO 1
xS1-BT120-TSPO
xS1-BT120-CLP0T
xS1-BT120-APP2
xS1-BT120-LHP01
xS1-BT120-LPP06
xS1-BT120-CMP
xBRT-CUD05-TB
xS1-BT120-GZKO
xS1-BT120-CAPO
xS1-BT120-VSF100
GB-SEAL-RJH43665
xS1-BT120-JCP101
xS1-BT120-EPP101
xS1-BT120-JCP001
xS1-BT120-GZKO10
xS1-BT120-TIP001
xS1-BT120-CZN002
N
O
a
J
6
N
m
0
N
c—o
0
0
O
z
X
w
(D
Z U
Q W
06
Z m
LLJ
0 CO
_o
�a
coz
CD_
N v
N
a
o U
GENERAL NOTES:
1. SEE SHEET BT120-CLP100 FOR ILLUMINATION
GENERAL NOTES.
2. SEE SHEET BT120-CLN101 FOR ILLUMINATION
LEGEND.
3. SEE SHEET BT120-CLS101 FOR ILLUMINATION
WIRING SCHEDULE
4. SEE SHEET BT120-CLS102 THROUGH
BT120-CLS103 FOR ILLUMINATION POLE
SCHEDULE.
5. ALL EXISTING ILLUMINATION NOT CALLED OUT
TO BE REMOVED SHALL BE MAINTAINED AND
PROTECTED.
6. SEE SIGNAL SHEET BT120-TSD101 FOR
LUMINAIRES ON SIGNAL POLES AND
7. REFER TO CITY OF RENTON STANDARD PLAN 135
FOR ADDITIONAL TRANSPORTATION NOTES.
1
06/13/2025
OW
RT
I RH
ADDENDUM #1
12/10/2024
OW
RT
RH
ISSUED FOR BID
L0
No.
DATE
DSN
CHK
I APP
REVISION
1
Ivi11%1 Vf7L11VG.
SEE DWG BT120-CLP203
CONSTRUCTION NOTES:
UINSTALL PEDESTRIAN SCALE LUMINAIRE POLE WITH 2' LUMINAIRE ARM AND
FOUNDATION WITH NEW LED FIXTURE PER CITY OF RENTON STANDARD
PLAN 117.2. FOUNDATION DEPTH SHALL BE 5' MINIMUM.
10 INSTALL TYPE 2 JUNCTION BOX PER CITY OF RENTON STANDARD PLAN 119.
11 INSTALL TYPE 8 JUNCTION BOX PER WSDOT STANDARD PLAN J-40.30-04. 1
INSTALL CONCRETE PAD PER CITY OF RENTON STANDARD PLAN 120.
13 MAINTAIN AND PROTECT EXISTING LIGHT POLE, LUMINAIRE ARM, LUMINAIRE,
AND FOUNDATION.
17 PROPOSED PSE POWER SOURCE LOCATION. COORDINATE FINAL SERVICE
CONNECTION WITH PSE REPRESENTATIVE. REFERENCE PSE CUSTOMER
DRAWING FOR ELECTRICAL ORDER #104364659.
19 REMOVE EXISTING LIGHTING CONDUCTORS. EXISTING CONDUIT TO REMAIN
AS SPARE.
20 REMOVE AND SALVAGE EXISTING STREET LIGHT POLE, BRACKET ARM, AND
LUMINAIRE. REMOVE EXISTING LIGHT POLE FOUNDATION AND ASSOCIATED
CONDUIT AND WIRING.
21 PROTECT IN PLACE EXISTING JUNCTION BOX. REMOVE EXISTING LIGHTING
CONDUCTORS SOUTH TO NEAREST JUNCTION BOX.
22 PROTECT IN PLACE EXISTING SPARE CONDUIT.
DESIGNED BY:
R. TLEHHEMA
DRAWN BY:
R. SNELLINGS
CHECKED BY:
E. SHIMIZU
APPROVED BY:
R. HUTCHINSON
H
r ijjjngjW
43665
�GISTER� V
IDNAI �SUBMITTED BY:
6/12/2025 R. PARGAS
MATCHLINE:
SEE DWG BT120-CLP201
29 INSTALL CONCRETE PAD PER CITY OF RENTON STANDARD PLAN 120.
30 LUMINAIRE ON SIGNAL MAST ARM POLE. SEE TRAFFIC SIGNAL SHEETS
BT120-TSD101, BT120-TSD102 AND BT120-TSS101 THROUGH BT120-TSS104
FOR DETAILS.
1
I 103 I
L I I
102 201 — 107
SC1O
203
204 J Q
205 105
101 104 III
GR DY l�
WAY
c!
TRANSPORTATION OPERATION
CBarnes 12/01 /2025
SCALE:
J 1 "=20'
Q
Q FILENAME:
4,5r,RIDE (n co
w J S1-BT120-CLP102
BRT General Engineering Consultant Z-L " SOUNDTRANSIT CONTRACT No.:
RTA/CN 0205-24
DATE: REVIEWED BY: DATE: DATE:
12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024
KEY MAP
UPDATES TO ROW
SEE SHEETS
BT120-RPP101-BT120-RPP102
BT120-RPP105-BT120-RPP106
BT1 20-RPP201 -BT1 20-RPP205
20
10
0
20
40
SCALE IN FEET
DEVELOPMENT ENGINEERING
msippo 11 /25/2025 1 T-433227
InRAWIN(, Nn
STRIDE BUS RAPID TRANSIT
SOUTH RENTON TRANSIT CENTER
BT105
CIVIL
ILLUMINATION PLAN
RAINIER STA 204+00 TO RAINIER STA 208+50
BT120-CLP102
FACILITY ID:
BT120
SHEET No.: REV:
188 1
C'7
N
T
N
0
0
N
CU
co
N
O
O
1
N
Q
J